KH-2
KHEA/KHNA30F
AC-DC Power Supplies DIN Rail Type
KHO A 30 F -OO -O
Ordering information
1
Series name
KHE
:
Euro style I/O terminals
KHN
:
Barrier blocks style
I/O terminals
2
Single output
3
Output wattage
4
Universal input
5
Output voltage
6
Option
C
: with Coating
1 2 3 4 5 6
MODEL KHEA/KHNA30F-5 KHEA/KHNA30F-12 KHEA/KHNA30F-24
MAX OUTPUT WATTAGE[W] 25 27.6 31.2
DC OUTPUT 5V 5A 12V 2.3A 24V 1.3A
SPECIFICATIONS
MODEL KHEA/KHNA30F-5 KHEA/KHNA30F-12 KHEA/KHNA30F-24
INPUT
VOLTAGE[V]
AC85 - 264 1
f
(Refer to
“
Derating
”
) or DC88 - 370
*
11
CURRENT[A]
ACIN 115V
0.45typ 0.50typ 0.55typ
ACIN 230V
0.30typ 0.30typ 0.35typ
FREQUENCY[Hz]
50 / 60 (45 - 440) or DC
EFFICIENCY[%]
ACIN 115V
84.0typ 87.0typ 88.5typ
ACIN 230V
85.5typ 88.5typ 89.5typ
INRUSH CURRENT[A]
*
1
ACIN 115V
18typ (Io=100%
)
(at cold start Ta=25
C
)
ACIN 230V
35typ (Io=100%
)
(at cold start Ta=25
C
)
LEAKAGE CURRENT[mA]
0.45 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
OUTPUT
VOLTAGE[V]
5 12 24
CURRENT[A]
5.0 2.3 1.3
PEAK CURRENT[A]
- - -
LINE REGULATION[mV]
*
2
20max 48max 96max
LOAD REGULATION[mV]
*
2
80max 100max 150max
RIPPLE[mVp-p]
*
3
0 to +70C
150max 150max 150max
-20 - 0C
300max 300max 300max
Io=0 - 30%
300max
*
4
300max
*
4
300max
*
4
RIPPLE NOISE[mVp-p]
*
3
0 to +70C
180max 180max 180max
-20 - 0C
360max 360max 360max
Io=0 - 30%
360max
*
4
360max
*
4
360max
*
4
TEMPERATURE REGULATION[mV]
0 to +70C
50max 120max 240max
-20 to +70C
60max 150max 290max
DRIFT[mV]
*
5
20max 48max 96max
START-UP TIME[ms]
200typ (ACIN 115V, Io=100%)
HOLD-UP TIME[ms]
20typ (ACIN 115V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
4.50 to 5.50 10.80 to 13.20 22.50 to 28.50
OUTPUT VOLTAGE SETTING[V]
5.00 to 5.15 12.00 to 12.48 24.00 to 24.96
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
*
10
OVERVOLTAGE PROTECTION[V]
6.30 to 7.60 13.80 to 16.80 30.00 to 36.00
DC_OK LAMP
LED (Green)
ISOLATION
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min
(
At Room Temperature
)
INPUT-PE
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min
(
At Room Temperature
)
OUTPUT-PE
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min
(
At Room Temperature
)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-20 to +70
C
, 20 - 90%RH (Non condensing), Type tested for -40
C
start-up (Refer to
“
Derating
”
)
STORAGE TEMP.,HUMID.AND ALTITUDE
-30 to +85
C
, 20 - 90%RH (Non condensing)
VIBRATION
*
8
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60 minutes along Z axis (Non operating, mounted on DIN Rail)
IMPACT
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis (Packing state)
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS AC input
UL60950-1, C-UL (CSA60950-1), EN60950-1, UL508 (NEC Class2 per UL1310), ANSI/ISA12.12.01, ATEX, Complies with DEN-AN
*
DC input
UL60950-1, C-UL (CSA60950-1), EN60950-1
CONDUCTED NOISE
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
HARMONIC ATTENUATOR
Complies with IEC61000-3-2 (Class A)
*
6
(
Not built-in to active filter)
*
9
OTHERS
CASE SIZE
*
7
22.5
X
75
X
90mm (W
X
H
X
D) [0.89
X
2.95
X
3.54 inches]
WEIGHT
165g max
COOLING METHOD
Convection
*
1
The value is primary surge. The current of input surge to a built-in EMI/EMC Filter(0.2ms or less)is
excluded.
*
2 Please contact us about dynamic load and input response.
*
3 T
his is the value that measured on measuring board with capacitor of 22
m
F and 0.1
m
F at 150mm from
output terminal.
Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103).
Please refer to the instruction manual 1.7.
Ripple and ripple noise spec is change at Io=0 to 30% by burst operation.
*
4 In case of operating under 0
C
ambient temperature, the value is two times of specification at 0 to
30% load factor.
*
5 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25
C
, with the
input voltage held constant at the rated input/output.
*
6 Please contact us about another class.
*
7 Case size contains neither the umbo.
*
8 Only as standard mounting orientation (A). Refer to the
“
Assembling and Installation Method
”
.
If install other than standard mounting orientation (A), please fix the power supply for withstand the
vibration and impact.
*
9 When two or more units are operating it may not comply with the IEC61000-3-2.
*
10
If the overcurrent protection circuit operates continuously, the output voltage shut down. Refer to
the instruction manual 1.3.
*
11
Under low DC input voltage below DC110V, the temperature derating -1
C
/V or the output power
derating -1%/V are required.
*
To meet the specifications. Do not operate over-loaded condition.
*
A sound may occur from power supply at light or peak loading.
R
Example recommended EMI/EMC filter
NAC-04-472-D
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
June 29, 2020