Input Specifications
Input current at no load ±12 & ±15 VDC models, 24 V: 30 mA typ.
(nominal input) other models, 24 V: 100 mA typ.
±12 & ±15 V models, 48 V: 15 mA typ.
other models, 48 V: 55 mA typ.
Input current at full load 3.3 VDC model, 24 V: 1250 mA typ.
other models, 24 V: 1500 mA typ.
3.3 VDC model, 48 V: 630 mA typ.
other models, 48 V: 750 mA typ.)
Start-up voltage / under voltage lockout 24 V models: 9 VDC / 8 VDC (typ.)
48 V models: 18 VDC / 16 VDC (typ.)
Surge voltage (100 msec. max.) 24 V models: 50 VDC max.
48 V models: 100 VDC max
Conducted noise (input) EN 55022 class A with input capacitor
24 V models: 4.7 µF / 50 V 1812 MLCC
48 V models: 2.2 µF / 100 V 1812 MLCC)
ESD (electrostatic discharge) EN 61000-4-2, air ±8 kV, contact ±6 kV,
perf. criteria A
Radiated immunity EN 61000-4-3, 10 V/m, perf. criteria A
Fast transient / Surge (with external capacitor) EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV, perf. criteria A
– external capacitor 24 V models: Nippon chemi-con KY, 330 µF / 50 V
48 V models: Nippon chemi-con KY, 220 µF / 100 V
Conducted immunity EN 61000-4-6, 10 Vrms, perf. criteria A
Magnetic field immunity EN 61000-4-8, 100 A/m, perf. criteria A
Output Specifications
Voltage set accuracy ±1 % (±5 % for auxilary outputs)
Output voltage adjustment (only for single output models) ±10 % with external resistor (see page 3)
Regulation – Input variation single- and dual output models: 0.25 % max.
triple output models: 1 % / 5 % max. (main / auxilary)
– Load variation single output models: 0.5 % max. (0 – 100 %)
dual output models balanced load: 1 % max. (0 – 100 %)
dual output models unbalanced load: 5 % max. (25 / 100 %)
triple output models (main/auxiliary): 1 % max. / 5 % max. (10 – 100 %)
Minimum load
single- and dual output models:
not required
triple output models:
10% of rated max current on each output
(operation at lower load condition will not damage
the converters. However, they may not meet all listed
specifications)
Temperature coefficient ±0.02 %/K max.
Ripple and noise (20 MHz Bandwidth) 1.5 V – 5.1 VDC models: 100 mVpk-pk. typ.
triple output models: 50 / 75 mVpk-pk typ. (main / auxilary)
other models: 150 mVpk-pk typ.
Start up time (nominal Vin and constant resistive load) 30 ms typ.
Transient response time (25% load change) 250 µs typ.
Short circuit protection indefinite (automatic recovery)
Over load protection 150 % of Iout max. typ.
Thermal shutdown at +115°C typ.
DC/DC Converters
TEN 30WIN 30 Watt
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.