DS12R885/DS12CR887/ DS12R887 RTCs with Constant-Voltage Trickle Charger General Description Features The DS12R885 is a functional drop-in replacement for the DS12885 real-time clock (RTC). The device provides an RTC/calendar, one time-of-day alarm, three maskable interrupts with a common interrupt output, a programmable square wave, and 114 bytes of batterybacked static RAM. The date at the end of the month is automatically adjusted for months with fewer than 31 days, including correction for leap years. It also operates in either 24-hour or 12-hour format with an AM/PM indicator. A precision temperature-compensated circuit monitors the status of VCC. If a primary power failure is detected, the device automatically switches to a backup supply. The VBACKUP pin supports a rechargeable battery or a super cap and includes an integrated, always enabled trickle charger. The DS12R885 is accessed through a multiplexed byte-wide interface, which supports both Intel and Motorola modes. The DS12CR887 and DS12R887 integrate the DS12R885 die with a crystal and battery. o Trickle-Charge Capability for a Rechargeable Battery or Super Cap o Selectable Intel or Motorola Bus Timing o RTC Counts Seconds, Minutes, Hours, Day, Date, Month, and Year with Leap-Year Compensation to 2100 o Interrupt Output with Three Independently Maskable Interrupt Flags o Time-of-Day Alarm is Once-per-Second to Onceper-Day o Periodic Rates from 122s to 500ms o End-of-Clock Update Cycle Flag o 14 Bytes of Clock and Control Registers o 114 Bytes of General-Purpose Battery-Backed NV RAM with Clear Input o Programmable Square-Wave Output o Automatic Power-Fail Detect and Switch Circuitry o +5.0V or +3.3V Operation o Industrial Temperature Range o DS12CR887 Encapsulated DIP (EDIP) Module with Integrated Battery and Crystal o DS12R887 BGA Module Surface-Mountable Package with Integrated Crystal and Rechargeable Battery Applications Embedded Systems Utility Meters Security Systems Network Hubs, Bridges, and Routers Typical Operating Circuit CRYSTAL X1 AS DS RESET RCLR DS12R885 CS AD(0-7) SQW VBACKUP IRQ MOT GND PINPACKAGE DS12R885S-5+ -40C to +85C 24 SO (300 mils) DS12R885-5 DS12R885S-5+ T&R -40C to +85C 24 SO (300 mils) DS12R885-5 DS12R885S-33+ -40C to +85C 24 SO (300 mils) DS12R885-33 DS12R885S-33+ 24 SO -40C to +85C T&R (300 mils) DS12R885-33 DS12CR887-5+ -40C to +85C 24 EDIP (700 mils) DS12CR887-5 DS12CR887-33+ -40C to +85C 24 EDIP (700 mils) DS12CR887-33 VCC R/W DS83C520 TEMP RANGE PART VCC X2 Ordering Information SUPER CAP Pin Configurations appear at end of data sheet. TOP MARK* DS12R887-5 -20C to +60C 48 BGA DS12R887-5 DS12R887-33 -20C to +60C 48 BGA DS12R887-33 +Denotes a lead(Pb)-free/RoHS-compliant package. T&R = Tape and reel. *A "+" anywhere on the top mark indicates a lead(Pb)-free device. For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642, or visit Maxim's website at www.maximintegrated.com. 19-5217; Rev 8; 1/15 DS12R885/DS12CR887/DS12R887 RTCs with Constant-Voltage Trickle Charger ABSOLUTE MAXIMUM RATINGS Voltage Range on VCC Pin Relative to Ground .....-0.3V to +6.0V Operating Temperature Range ...........................-40C to +85C Operating Temperature Range (DS12R887-33 and DS12R887-5) ....................-20C to +60C Operating Temperature Range (All others) .........-20C to +60C Storage Temperature Range EDIP ..................................................................-40C to +85C SO ...................................................................-55C to +125C BGA ..................................................................-20C to +60C Lead Temperature (soldering, 10s) .................................+260C (Note: EDIP is hand or wave-soldered only.) Soldering Temperature (reflow) SO .................................................................................+260C BGA...............................................................................+225C Stresses beyond those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. DC ELECTRICAL CHARACTERISTICS (VCC = VCC(MIN) to VCC(MAX), TA = -40C to +85C, (DS12R887-33 and DS12R887-5, TA = -20C to +60C), unless otherwise noted.) (Note 1) PARAMETER SYMBOL CONDITIONS MIN TYP MAX -33 2.97 3.3 3.63 -5 4.5 5.0 5.5 UNITS Supply Voltage (Note 2) VCC VBACKUP Input Voltage (DS12R885 Only) VBACKUP (Note 2) 2.0 VOUT V Input Logic 1 VIH (Note 2) 2.2 VCC + 0.3 V Input Logic 0 VIL (Note 2) -0.3 +0.8 V VCC Power-Supply Current (Note 3) ICC1 VCC Standby Current (Note 4) ICCS -33 0.7 2 -5 0.8 2 -5 0.250 0.5 -33 0.140 0.3 V mA mA Input Leakage I IL -1.0 +1.0 A I/O Leakage I OL (Note 5) -1.0 +1.0 A Input Current IMOT (Note 6) -1.0 +500 A Output Current at 2.4V I OH (Note 2) -1.0 Output Current at 0.4V I OL (Note 2) 4.0 mA Power-Fail Voltage (Note 2) VPF VRT Trip Point VRTTRIP mA -33 2.7 2.88 2.97 -5 4.05 4.33 4.5 -33 -5 V 1.3 V Trickle-Charger Current-Limiting Resistor R1 DS12R885 Only 10 k Trickle-Charger Output Voltage VOUT DS12R885 Only 3.05 V 2 Maxim Integrated DS12R885/DS12CR887/DS12R887 RTCs with Constant-Voltage Trickle Charger DC ELECTRICAL CHARACTERISTICS (DS12R885 Only) (VCC = 0V, VBACKUP = 3.2V, TA = -40C to +85C, unless otherwise noted.) (Note 1) PARAMETER VBACKUP Current (OSC On); TA = +25C, VBACKUP = 3.0V VBACKUP Current (Oscillator Off) SYMBOL IBACKUP2 CONDITIONS MIN (Note 7) TYP MAX UNITS 800 1000 nA 100 nA MAX UNITS DC ns IBACKUPDR (Note 7) AC ELECTRICAL CHARACTERISTICS (VCC = 4.5V to 5.5V, TA = -40C to +85C, (DS12R887-33 and DS12R887-5, TA = -20C to +60C.)) (Note 1) PARAMETER SYMBOL CONDITIONS MIN TYP Cycle Time Pulse Width, DS Low or R/W tCYC 180 PWEL 80 ns Pulse Width, DS High or R/W PWEH 65 ns Input Rise and Fall tR, tF R/W Hold Time tRWH 0 30 ns R/W Setup Time Before DS/E tRWS 10 ns Chip-Select Setup Time Before DS or R/W tCS 5 ns Chip-Select Hold Time tCH 0 ns 35 ns Read-Data Hold Time tDHR 5 Write-Data Hold Time tDHW 0 ns ns Address Valid Time to AS Fall tASL 20 ns Address Hold Time to AS Fall tAHL 5 ns Delay Time DS/E to AS Rise tASD 10 ns Pulse Width AS High PWASH 30 ns Delay Time, AS to DS/E Rise tASED 35 ns Output Data Delay Time from DS or R/W tDDR Data Setup Time tDSW 50 ns Reset Pulse Width tRWL 5 s IRQ Release from DS t IRDS 0 2 s IRQ Release from RESET t IRR 0 2 s Maxim Integrated (Note 8) 15 60 ns 3 DS12R885/DS12CR887/DS12R887 RTCs with Constant-Voltage Trickle Charger AC ELECTRICAL CHARACTERISTICS (VCC = 2.97V to 3.63V, TA = -40C to +85C, (DS12R887-33 and DS12R887-5, TA = -20C to +60C.)) (Note 1) PARAMETER Cycle Time SYMBOL tCYC CONDITIONS MIN 280 TYP MAX DC UNITS ns Pulse Width, DS Low or R/W High PWEL 130 ns Pulse Width, DS High or R/W Low PWEH 90 ns Input Rise and Fall tR, tF R/W Hold Time tRWH 0 ns R/W Setup Time Before DS tRWS 15 ns Chip-Select Setup Time Before DS or R/W tCS 8 ns Chip-Select Hold Time tCH 0 ns 30 Read-Data Hold Time tDHR 5 Write-Data Hold Time tDHW 0 ns Address Valid Time to AS Fall tASL 30 ns Address Hold Time to AS Fall tAHL 15 ns Delay Time DS to AS Rise tASD 15 ns PWASH 45 ns Delay Time, AS to DS Rise tASED 55 ns Output Data Delay Time from DS or R/W tDDR Data Setup Time tDSW 70 Reset Pulse Width tRWL 5 IRQ Release from DS t IRDS 0 2 s IRQ Release from RESET t IRR 0 2 s Pulse Width AS High 4 (Note 8) 20 55 ns 80 ns ns ns s Maxim Integrated DS12R885/DS12CR887/DS12R887 RTCs with Constant-Voltage Trickle Charger Motorola Bus Read/Write Timing PWASH tASED AS tASD tCYC PWEH PWEL DS tRWS tRWH R/ W tCH tCS CS tDSW tDHW AD0-AD7 WRITE tAHL tASL tDHR AD0-AD7 READ tDDR Intel Bus Write Timing tCYC AS PWASH tASD DS tASED tASD R/W PWEH PWEL tCH tCS CS tASL tAHL tDSW tDHW AD0-AD7 WRITE Maxim Integrated 5 DS12R885/DS12CR887/DS12R887 RTCs with Constant-Voltage Trickle Charger Intel Bus Read Timing tCYC PWASH AS tASD tASED DS PWEH PWEL tASD R/W tCH tCS CS tASL tDHR tDDR tAHL AD0-AD7 IRQ Release Delay Timing DS RESET tRWL IRQ tIRR tIRDS Power-Up/Power-Down Timing VCC VPF(MAX) VPF(MIN) tF tR tRPU tDR INPUTS RECOGNIZED DON'T CARE RECOGNIZED HIGH-Z OUTPUTS 6 VALID VALID Maxim Integrated DS12R885/DS12CR887/DS12R887 RTCs with Constant-Voltage Trickle Charger POWER-UP/POWER-DOWN CHARACTERISTICS (TA = -40C to +85C, (DS12R887-33 and DS12R887-5, TA = -20C to +60C.)) (Note 1) PARAMETER SYMBOL Recovery at Power-Up CONDITIONS MIN TYP MAX UNITS 200 ms tRPU 20 VCC Fall Time; VPF(MAX) to VPF(MIN) tF 300 s VCC Rise Time; VPF(MIN) to VPF(MAX) tR 0 s DATA RETENTION (DS12CR887) PARAMETER SYMBOL Expected Data Retention tDR CONDITIONS TA = +25C MIN TYP MAX 5 UNITS Years CAPACITANCE (TA = +25C) PARAMETER SYMBOL Capacitance on All Input Pins Except X1 and X2 CIN Capacitance on IRQ, SQW, and DQ Pins CIO CONDITIONS MIN TYP MAX UNITS (Note 9) 10 pF (Note 9) 10 pF AC TEST CONDITIONS PARAMETER Input Pulse Levels (-5) TEST CONDITIONS 0 to 3.0V Input Pulse Levels (-33) 0 to 2.7V Output Load Including Scope and Jig (-5) 50pF + 1TTL Gate Output Load Including Scope and Jig (-33) 25pF + 1TTL Gate Input and Output Timing Measurement Reference Levels Input/Output: VIL maximum and VIH minimum Input-Pulse Rise and Fall Times 5ns WARNING: Negative undershoots below -0.3V while the part is in battery-backed mode may cause loss of data. Note 1: Note 2: Note 3: Note 4: Note 5: Note 6: Note 7: Note 8: Note 9: Limits at -40C are guaranteed by design and not production tested. All voltages are referenced to ground. All outputs are open. Specified with CS = DS = R/W = RESET = VCC; MOT, AS, AD0-AD7 = 0; VBACKUP open. Applies to the AD0 to AD7 pins, the IRQ pin, and the SQW pin when each is in a high-impedance state. The MOT pin has an internal 20k pulldown. Measured with a 32.768kHz crystal attached to X1 and X2. Measured with a 50pF capacitance load. Guaranteed by design. Not production tested. Maxim Integrated 7 DS12R885/DS12CR887/DS12R887 RTCs with Constant-Voltage Trickle Charger Typical Operating Characteristics (VCC = +3.3V, TA = +25C, unless otherwise noted.) IBACKUP vs. VBACKUP (DS12R885) VBACKUP vs. VCC vs. IBACKUP (DS12R885) DS12R885 toc02 3.0 0A -15A 2.8 600 VBACKUP (V) SUPPLY CURRENT (nA) VCC = 0V DS12R885 toc01 625 -30A 2.6 -45A 2.4 575 -60A 2.2 550 2.0 2.3 2.5 2.8 3.0 VCC (V) IBACKUP vs. TEMPERATURE (DS12R885) OSCILLATOR FREQUENCY vs. SUPPLY VOLTAGE 32768.08 32768.06 600 FREQUENCY (Hz) SUPPLY CURRENT (nA) VCC = 0V, VBACKUP = 3.0V 575 550 525 32768.04 32768.02 32768.00 32767.98 32767.96 500 32767.94 475 32767.92 32767.90 450 -40 -25 -10 5 20 35 50 TEMPERATURE (C) 8 32768.10 DS12R885 toc03 650 625 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 VBACKUP (V) DS12R885 toc04 2.0 65 80 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 SUPPLY (V) Maxim Integrated DS12R885/DS12CR887/DS12R887 RTCs with Constant-Voltage Trickle Charger Functional Diagram X1 OSC DIVIDE BY 8 DIVIDE BY 64 DIVIDE BY 64 X2 DS12R887/ DS12CR887 ONLY VCC GND DS12R887/ DS12CR887 ONLY 16:1 MUX POWER CONTROL AND TRICKLE CHARGER VBACKUP DS12R885 SQUAREWAVE GENERATOR SQW IRQ GENERATOR IRQ CS R/W REGISTERS A, B, C, D DS BUS INTERFACE AS MOT RESET CLOCK/CALENDAR UPDATE LOGIC CLOCK/CALENDAR AND ALARM REGISTERS BUFFERED CLOCK/ CALENDAR AND ALARM REGISTERS AD0-AD7 USER RAM 114 BYTES RLCR Pin Description SO PIN EDIP BGA 1 1 C5 MOT 2 -- -- X1 3 -- -- X2 4-11 4-11 Maxim Integrated F4, D4, F3, D3, F2, D2, F1, D1 NAME AD0- AD7 FUNCTION Motorola or Intel Bus Timing Selector. This pin selects one of two bus types. When connected to VCC, Motorola bus timing is selected. When connected to GND or left disconnected, Intel bus timing is selected. The pin has an internal pulldown resistor. Connections for Standard 32.768kHz Quartz Crystal. The internal oscillator circuitry is designed for operation with a crystal having a 12.5pF specified load capacitance (CL). Pin X1 is the input to the oscillator and can optionally be connected to an external 32.768kHz oscillator. The output of the internal oscillator, pin X2, is left unconnected if an external oscillator is connected to pin X1. Multiplexed, Bidirectional Address/Data Bus. The addresses are presented during the first portion of the bus cycle and latched into the DS12R885 by the falling edge of AS. Write data is latched by the falling edge of DS (Motorola timing) or the rising edge of R/W (Intel timing). In a read cycle, the DS12R885 outputs data during the latter portion of DS (DS and R/W high for Motorola timing, DS low and R/W high for Intel timing). The read cycle is terminated and the bus returns to a high-impedance state as DS transitions low in the case of Motorola timing or as DS transitions high in the case of Intel timing. 9 DS12R885/DS12CR887/DS12R887 RTCs with Constant-Voltage Trickle Charger Pin Description (continued) SO PIN EDIP 12, 16 12 13 14 14 D5-D8, E1-E8, F5-F8 C1 C3 NAME GND FUNCTION Ground CS Chip-Select Input. The active-low chip-select signal must be asserted low for a bus cycle in the DS12R885 to be accessed. CS must be kept in the active state during DS and AS for Motorola timing and during DS and R/W for Intel timing. Bus cycles that take place without asserting CS latch addresses, but no access occurs. When VCC is below VPF volts, the DS12R885 inhibits access by internally disabling the CS input. This action protects the RTC data and the RAM data during power outages. AS Address Strobe Input. A positive-going address-strobe pulse serves to demultiplex the bus. The falling edge of AS causes the address to be latched within the DS12R885. The next rising edge that occurs on the AS bus clears the address regardless of whether CS is asserted. An address strobe must immediately precede each write or read access. If a write or read is performed with CS deasserted, another address strobe must be performed prior to a read or write access with CS asserted. 15 15 C2 R/W Read/Write Input. The R/W pin has two modes of operation. When the MOT pin is connected to VCC for Motorola timing, R/W is at a level that indicates whether the current cycle is a read or write. A read cycle is indicated with a high level on R/W while DS is high. A write cycle is indicated when R/W is low during DS. When the MOT pin is connected to GND for Intel timing, the R/W signal is an active-low signal. In this mode, the R/W pin operates in a similar fashion as the write-enable signal (WE) on generic RAMs. Data are latched on the rising edge of the signal. 22 2, 3, 16, 20-22 A3 N.C. No Connection. This pin should remain unconnected. On the EDIP, these pins are missing by design. 17 10 13 BGA 17 A1 DS Data Strobe or Read Input. The DS pin has two modes of operation depending on the level of the MOT pin. When the MOT pin is connected to VCC, Motorola bus timing is selected. In this mode, DS is a positive pulse during the latter portion of the bus cycle and is called data strobe. During read cycles, DS signifies the time that the DS12R885 is to drive the bidirectional bus. In write cycles, the trailing edge of DS causes the DS12R885 to latch the written data. When the MOT pin is connected to GND, Intel bus timing is selected. DS identifies the time period when the DS12R885 drives the bus with read data. In this mode, the DS pin operates in a similar fashion as the output-enable (OE) signal on a generic RAM. Maxim Integrated DS12R885/DS12CR887/DS12R887 RTCs with Constant-Voltage Trickle Charger Pin Description (continued) PIN SO 18 EDIP 18 BGA A2 NAME FUNCTION RESET Reset Input. The active-low RESET pin has no effect on the clock, calendar, or RAM. On power-up, the RESET pin can be held low for a time to allow the power supply to stabilize. The amount of time that RESET is held low is dependent on the application. However, if RESET is used on power-up, the time RESET is low should exceed 200ms to ensure that the internal timer that controls the DS12R885 on power-up has timed out. When RESET is low and VCC is above VPF, the following occurs: A. Periodic interrupt-enable (PIE) bit is cleared to 0. B. Alarm interrupt-enable (AIE) bit is cleared to 0. C. Update-ended interrupt-enable (UIE) bit is cleared to 0. D. Periodic-interrupt flag (PF) bit is cleared to 0. E. Alarm-interrupt flag (AF) bit is cleared to 0. F. Update-ended interrupt flag (UF) bit is cleared to 0. G. Interrupt-request status flag (IRQF) bit is cleared to 0. H. IRQ pin is in the high-impedance state. I. The device is not accessible until RESET is returned high. J. Square-wave output-enable (SQWE) bit is cleared to 0. In a typical application, RESET can be connected to VCC. This connection allows the DS12R885 to go in and out of power fail without affecting any of the control registers. IRQ Interrupt Request Output. The IRQ pin is an active-low output of the DS12R885 that can be used as an interrupt input to a processor. The IRQ output remains low as long as the status bit causing the interrupt is present and the corresponding interrupt-enable bit is set. The processor program normally reads the C register to clear the IRQ pin. The RESET pin also clears pending interrupts. When no interrupt conditions are present, the IRQ level is in the high-impedance state. Multiple interrupting devices can be connected to an IRQ bus, provided that they are all open drain. The IRQ pin is an opendrain output and requires an external pullup resistor to VCC. 19 19 A4 20 -- -- Connection for Rechargeable Battery or Super Cap. This pin provides trickle charging VBACKUP when VCC is greater than VBACKUP. On the DS12CR887 and DS12R887, the VBACKUP pin is missing and is internally connected to a lithium cell. A5 RCLR RAM Clear. The active-low RCLR pin is used to clear (set to logic 1) all 114 bytes of general-purpose RAM, but does not affect the RAM associated with the RTC. To clear the RAM, RCLR must be forced to an input logic 0 during battery-backup mode when VCC is not applied. The RCLR function is designed to be used through a human interface (shorting to ground manually or by a switch) and not to be driven with external buffers. This pin is internally pulled up. Do not use an external pullup resistor on this pin. 21 -- 23 23 C4 SQW Square-Wave Output. The SQW pin can output a signal from one of 13 taps provided by the 15 internal divider stages of the RTC. The frequency of the SQW pin can be changed by programming Register A, as shown in Table 3. The SQW signal can be turned on and off using the SQWE bit in Register B. The SQW signal is not available when VCC is less than VPF. 24 24 A6-A8, B1-B8, C6-C8 VCC DC Power Pin for Primary Power Supply. When VCC is applied within normal limits, the device is fully accessible and data can be written and read. When VCC is below VPF reads and writes are inhibited. Maxim Integrated 11 DS12R885/DS12CR887/DS12R887 RTCs with Constant-Voltage Trickle Charger Detailed Description The DS12R885 is a drop-in replacement for the DS12885 RTC. The device provides 14 bytes of realtime clock/calendar, alarm, and control/status registers and 114 bytes of nonvolatile, battery-backed static RAM. A time-of-day alarm, three maskable interrupts with a common interrupt output, and a programmable square-wave output are available. The DS12R885 also operates in either 24-hour or 12-hour format with an AM/PM indicator. A precision temperature-compensated circuit monitors the status of V CC . If a primary power-supply failure is detected, the device automatically switches to a backup supply. The backup supply input supports either a rechargeable battery or a super cap, and includes an integrated trickle charger. The trickle charger is always enabled. The DS12R885 is accessed through a multiplexed address/data bus that supports Intel and Motorola modes. The DS12R887 is a surface-mount package using the DS12R885 die, a 32.768kHz crystal, and a rechargeable battery. The device provides a real-time clock/calendar, one time-of-day alarm, three maskable interrupts with a common interrupt output, a programmable square wave, and 114 bytes of nonvolatile, batterybacked static RAM. The date at the end of the month is automatically adjusted for months with fewer than 31 days, including correction for leap years. It also operates in either 24-hour or 12-hour format with an AM/PM indicator. A precision temperature-compensated circuit monitors the status of VCC. If a primary power failure is detected, the device automatically switches to a backup battery included in the package. The device is accessed through a multiplexed byte-wide interface, which supports both Intel and Motorola modes. The DS12CR887 EDIP integrates a DS12R885 die with a crystal and battery. The charging circuit on the DS12R885 die is disabled. The battery has sufficient capacity to power the oscillator and registers for five years in the absence of VCC at +25C. The DS12R887 BGA includes a crystal and a rechargeable battery. A fully charged battery can power the oscillator and registers (typical current at +25C) in the absence of V CC for approximately 11 days (10% of capacity consumed) or 98 days (90% capacity consumed). When the discharge depth is 10% of capacity, the battery can be recharged up to 1,000 times. If the discharge depth is 90% of capacity, the battery can be recharged up to 30 times. Thus, the life of the device would be approximately 30 years (11 days X 1,000 cycles) or 8 years (98 days x 30 cycles). Charging time to full capacity is approximately two days with VCC applied. 12 Please consult related application notes for detailed information on battery lifetime versus depth of discharge, and expected product lifetime based upon battery cycles. Oscillator Circuit The DS12R885 uses an external 32.768kHz crystal. The oscillator circuit does not require any external resistors or capacitors to operate. Table 1 specifies several crystal parameters for the external crystal. Figure 1 shows a functional schematic of the oscillator circuit. An enable bit in the control register controls the oscillator. Oscillator startup times are highly dependent upon crystal characteristics, PC board leakage, and layout. High ESR and excessive capacitive loads are the major contributors to long startup times. A circuit using a crystal with the recommended characteristics and proper layout usually starts within one second. Table 1. Crystal Specifications* PARAMETER SYMBOL Nominal Frequency fO Series Resistance ESR Load Capacitance CL MIN TYP MAX UNITS 32.768 kHz 50 12.5 k pF *The crystal, traces, and crystal input pins should be isolated from RF generating signals. Refer to Application Note 58: Crystal Considerations with Dallas Real-Time Clocks (RTCs) for additional specifications. COUNTDOWN CHAIN CL1 CL2 RTC REGISTERS DS12R885 X1 X2 CRYSTAL Figure 1. Oscillator Circuit Showing Internal Bias Network Maxim Integrated DS12R885/DS12CR887/DS12R887 RTCs with Constant-Voltage Trickle Charger An external 32.768kHz oscillator can also drive the DS12R885. In this configuration, the X1 pin is connected to the external oscillator signal and the X2 pin is left unconnected. Clock Accuracy The accuracy of the clock is dependent upon the accuracy of the crystal and the accuracy of the match between the capacitive load of the oscillator circuit and the capacitive load for which the crystal was trimmed. Additional error is added by crystal frequency drift caused by temperature shifts. External circuit noise coupled into the oscillator circuit can result in the clock running fast. Figure 2 shows a typical PC board layout for isolation of the crystal and oscillator from noise. Refer to Application Note 58: Crystal Considerations with Dallas Real-Time Clocks (RTCs) for more detailed information. The DS12R887 and DS12CR887 are calibrated at the factory to an accuracy of 1 minute per month at +25C during data-retention time for the period tDR. Power-Down/Power-Up Considerations The real-time clock continues to operate regardless of the VCC input level, and the RAM and alarm memory locations remain nonvolatile. V BACKUP must remain within the minimum and maximum limits when VCC is not applied. When VCC is applied and exceeds VPF (power-fail trip point), the device becomes accessible after tREC--if the oscillator is running and the oscillator countdown chain is not in reset (Register A). This time allows the system to stablize after power is applied. If the oscillator is not enabled, the oscillator-enable bit is enabled on power-up, and the device becomes immediately accessible. Time, Calendar, and Alarm Locations The time and calendar information is obtained by reading the appropriate register bytes. The time, calendar, and alarm are set or initialized by writing the appropriate register bytes. The contents of the 10 time, calendar, and alarm bytes can be either binary or binary-coded decimal (BCD) format. The day-of-week register increments at midnight, incrementing from 1 through 7. The day-of-week register is Maxim Integrated LOCAL GROUND PLANE (LAYER 2) X1 CRYSTAL X2 NOTE: AVOID ROUTING SIGNAL LINES IN THE CROSSHATCHED AREA (UPPER LEFT QUADRANT) OF THE PACKAGE UNLESS THERE IS A GROUND PLANE BETWEEN THE SIGNAL LINE AND THE DEVICE PACKAGE. GND Figure 2. Layout Example used by the daylight saving function, so the value 1 is defined as Sunday. The date at the end of the month is automatically adjusted for months with fewer than 31 days, including correction for leap years. Before writing the internal time, calendar, and alarm registers, the SET bit in Register B should be written to logic 1 to prevent updates from occurring while access is being attempted. In addition to writing the 10 time, calendar, and alarm registers in a selected format (binary or BCD), the data mode bit (DM) of Register B must be set to the appropriate logic level. All 10 time, calendar, and alarm bytes must use the same data mode. The SET bit in Register B should be cleared after the data mode bit has been written to allow the RTC to update the time and calendar bytes. Once initialized, the RTC makes all updates in the selected mode. The data mode cannot be changed without reinitializing the 10 data bytes. Tables 2A and 2B show the BCD and binary formats of the time, calendar, and alarm locations. The 24/12 bit cannot be changed without reinitializing the hour locations. When the 12-hour format is selected, the higher-order bit of the hours byte represents PM when it is logic 1. The time, calendar, and alarm bytes are always accessible because they are double-buffered. Once per second the seven bytes are advanced by one second and checked for an alarm condition. If a read of the time and calendar data occurs during an update, a problem exists where seconds, minutes, hours, etc., may not correlate. The probability of reading incorrect time and calendar data is low. Several 13 DS12R885/DS12CR887/DS12R887 RTCs with Constant-Voltage Trickle Charger methods of avoiding any possible incorrect time and calendar reads are covered later in this text. The three alarm bytes can be used in two ways. First, when the alarm time is written in the appropriate hours, minutes, and seconds alarm locations, the alarm interrupt is initiated at the specified time each day, if the alarm-enable bit is high. In this mode, the "0" bits in the alarm registers and the corresponding time registers must always be written to 0 (Table 2A and 2B). Writing the 0 bits in the alarm and/or time registers to 1 can result in undefined operation. The second use condition is to insert a "don't care" state in one or more of the three alarm bytes. The don'tcare code is any hexadecimal value from C0 to FF. The two most significant bits of each byte set the don't-care condition when at logic 1. An alarm is generated each hour when the don't-care bits are set in the hours byte. Similarly, an alarm is generated every minute with don't-care codes in the hours and minute alarm bytes. The don't-care codes in all three alarm bytes create an interrupt every second. All 128 bytes can be directly written or read, except for the following: 1) Registers C and D are read-only. 2) Bit 7 of register A is read-only. 3) The MSB of the seconds byte is read-only. Table 2A. Time, Calendar, and Alarm Data Modes--BCD Mode (DM = 0) ADDRESS 00H BIT 7 0 01H 0 10 Seconds Seconds 02H 0 10 Minutes 03H 0 10 Minutes 04H 05H AM/PM 0 AM/PM 0 BIT 6 0 0 0 0 08H 0 0 09H BIT 3 10 Hours 10 Hours 0 0 07H 0AH 0 0 06H BIT 5 BIT 4 10 Seconds 10 Hours 10 Hours 0 0 BIT 2 BIT 1 Seconds FUNCTION Seconds RANGE 00-59 Seconds Alarm 00-59 Minutes Minutes 00-59 Minutes Minutes Alarm 00-59 Hours Hours 1-12 +AM/PM 00-23 Hours Hours Alarm 1-12 +AM/PM 00-23 0 Day 01-07 Date Day Date 01-31 Month Month 01-12 Year Year 00-99 Control -- -- 10 Date 0 10 Months BIT 0 10 Years UIP DV2 DV1 DV0 RS3 RS2 RS1 RS0 0BH SET PIE AIE UIE SQWE DM 24/12 DSE Control 0CH IRQF PF AF UF 0 0 0 0 Control -- 0DH VRT 0 0 0 0 0 0 0 Control -- 0EH-7F X X X X X X X X RAM -- X = Read/Write Bit. Note: Unless otherwise specified, the state of the registers is not defined when power is first applied. Except for the seconds register, 0 bits in the time and date registers can be written to 1, but may be modified when the clock updates. 0 bits should always be written to 0 except for alarm mask bits. 14 Maxim Integrated DS12R885/DS12CR887/DS12R887 RTCs with Constant-Voltage Trickle Charger Table 2B. Time, Calendar, and Alarm Data Modes--Binary Mode (DM = 1) ADDRESS 00H BIT 7 0 BIT 6 0 BIT 5 01H 0 0 Seconds Seconds Alarm 00-3B 02H 0 0 Minutes Minutes 00-3B 03H 0 0 Minutes Minutes Alarm 00-3B Hours 01-0C +AM/PM 00-17 Hours Alarm 01-0C +AM/PM 00-17 01-07 01-1F 01-0C 00-63 -- -- AM/PM 04H BIT 4 BIT 3 BIT 2 Seconds 0 0 BIT 0 FUNCTION Seconds Hours 0 0 Hours AM/PM 05H BIT 1 0 0 0 0 0 0 0 Hours Hours 0 06H 07H 08H 09H 0AH 0 0 0 0 UIP 0 0 0 DV2 DV1 0BH SET PIE AIE 0CH IRQF PF 0DH VRT 0 0EH-7F X X 0 Date DV0 Year RS3 RS2 RS1 RS0 Day Date Month Year Control UIE SQWE DM 24/12 DSE Control AF UF 0 0 0 0 Control -- 0 0 0 0 0 0 Control -- X X X X X X RAM -- 0 Day RANGE 00-3B Month X = Read/Write Bit. Note: Unless otherwise specified, the state of the registers is not defined when power is first applied. Except for the seconds register, 0 bits in the time and date registers can be written to 1, but may be modified when the clock updates. 0 bits should always be written to 0 except for alarm mask bits. Maxim Integrated 15 DS12R885/DS12CR887/DS12R887 RTCs with Constant-Voltage Trickle Charger Control Registers The DS12R885 has four control registers that are accessible at all times, even during the update cycle. Control Register A BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 UIP DV2 DV1 DV0 RS3 RS2 RS1 RS0 Bit 7: Update-In-Progress (UIP). This bit is a status flag that can be monitored. When the UIP bit is a 1, the update transfer occurs soon. When UIP is a 0, the update transfer does not occur for at least 244s. The time, calendar, and alarm information in RAM is fully available for access when the UIP bit is 0. The UIP bit is read-only and is not affected by RESET. Writing the SET bit in Register B to a 1 inhibits any update transfer and clears the UIP status bit. Bits 3 to 0: Rate Selector (RS3, RS2, RS1, RS0). These four rate-selection bits select one of the 13 taps on the 15-stage divider or disable the divider output. The tap selected can be used to generate an output square wave (SQW pin) and/or a periodic interrupt. The user can do one of the following: 1) Enable the interrupt with the PIE bit; 2) Enable the SQW output pin with the SQWE bit; Bits 6, 5, and 4: DV2, DV1, DV0. These three bits are used to turn the oscillator on or off and to reset the countdown chain. A pattern of 010 is the only combination of bits that turn the oscillator on and allow the RTC to keep time. A pattern of 11x enables the oscillator but holds the countdown chain in reset. The next update occurs at 500ms after a pattern of 010 is written to DV0, DV1, and DV2. 3) 16 Enable both at the same time and the same rate; or 4) Enable neither. Table 3 lists the periodic interrupt rates and the squarewave frequencies that can be chosen with the RS bits. These four read/write bits are not affected by RESET. Maxim Integrated DS12R885/DS12CR887/DS12R887 Control Register B BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 SET PIE AIE UIE SQWE DM 24/12 DSE Bit 7: SET. When the SET bit is 0, the update transfer functions normally by advancing the counts once per second. When the SET bit is written to 1, any update transfer is inhibited, and the program can initialize the time and calendar bytes without an update occurring in the midst of initializing. Read cycles can be executed in a similar manner. SET is a read/write bit and is not affected by RESET or internal functions of the DS12R885. Bit 6: Periodic Interrupt Enable (PIE). The PIE bit is a read/write bit that allows the periodic interrupt flag (PF) bit in Register C to drive the IRQ pin low. When the PIE bit is set to 1, periodic interrupts are generated by driving the IRQ pin low at a rate specified by the RS3-RS0 bits of Register A. A 0 in the PIE bit blocks the IRQ output from being driven by a periodic interrupt, but the PF bit is still set at the periodic rate. PIE is not modified by any internal DS12R885 functions, but is cleared to 0 on RESET. Bit 5: Alarm Interrupt Enable (AIE). This bit is a read/write bit that, when set to 1, permits the alarm flag (AF) bit in Register C to assert IRQ. An alarm interrupt occurs for each second that the three time bytes equal the three alarm bytes, including a don't-care alarm code of binary 11XXXXXX. The AF bit does not initiate the IRQ signal when the AIE bit is set to 0. The internal functions of the DS12R885 do not affect the AIE bit, but is cleared to 0 on RESET. Bit 4: Update-Ended Interrupt Enable (UIE). This bit is a read/write bit that enables the update-end flag (UF) bit in Register C to assert IRQ. The RESET pin going low or the SET bit going high clears the UIE bit. UIE is not modified by any internal DS12R885 functions, but is cleared to 0 on RESET. Maxim Integrated Bit 3: Square-Wave Enable (SQWE). When this bit is set to 1, a square-wave signal at the frequency set by the rate-selection bits RS3-RS0 is driven out on the SQW pin. When the SQWE bit is set to 0, the SQW pin is held low. SQWE is a read/write bit and is cleared by RESET. SQWE is low if disabled, and is high impedance when VCC is below VPF. SQWE is cleared to 0 on RESET. Bit 2: Data Mode (DM). This bit indicates whether time and calendar information is in binary or BCD format. The DM bit is set by the program to the appropriate format and can be read as required. This bit is not modified by internal functions or RESET. A 1 in DM signifies binary data, while a 0 in DM specifies BCD data. Bit 1: 24/12. The 24/12 control bit establishes the format of the hours byte. A 1 indicates the 24-hour mode and a 0 indicates the 12-hour mode. This bit is read/write and is not affected by internal functions or RESET. Bit 0: Daylight Saving Enable (DSE). This bit is a read/write bit that enables two daylight saving adjustments when DSE is set to 1. On the first Sunday in April, the time increments from 1:59:59 AM to 3:00:00 AM. On the last Sunday in October when the time first reaches 1:59:59 AM, it changes to 1:00:00 AM. When DSE is enabled, the internal logic tests for the first/last Sunday condition at midnight. If the DSE bit is not set when the test occurs, the daylight saving function does not operate correctly. These adjustments do not occur when the DSE bit is 0. This bit is not affected by internal functions or RESET. 17 DS12R885/DS12CR887/DS12R887 Control Register C BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 IRQF PF AF UF 0 0 0 0 Bit 7: Interrupt Request Flag (IRQF). This bit is set to 1 when any of the following are true: PF = PIE = 1 AF = AIE = 1 UF = UIE = 1 Any time the IRQF bit is 1, the IRQ pin is driven low. This bit can be cleared by reading Register C or with a RESET. Bit 6: Periodic Interrupt Flag (PF). This bit is readonly and is set to 1 when an edge is detected on the selected tap of the divider chain. The RS3 through RS0 bits establish the periodic rate. PF is set to 1 independent of the state of the PIE bit. When both PF and PIE are 1s, the IRQ signal is active and sets the IRQF bit. This bit can be cleared by reading Register C or with a RESET. Bit 5: Alarm Interrupt Flag (AF). A 1 in the AF bit indicates that the current time has matched the alarm time. If the AIE bit is also 1, the IRQ pin goes low and a 1 appears in the IRQF bit. This bit can be cleared by reading Register C or with a RESET. Bit 4: Update-Ended Interrupt Flag (UF). This bit is set after each update cycle. When the UIE bit is set to 1, the 1 in UF causes the IRQF bit to be a 1, which asserts the IRQ pin. This bit can be cleared by reading Register C or with a RESET. Bits 3 to 0: Unused. These bits are unused in Register C. These bits always read 0 and cannot be written. Control Register D BIT 7 VRT BIT 6 0 BIT 5 0 BIT 4 0 Bit 7: Valid RAM and Time (VRT). This bit indicates the condition of the battery connected to the VBACKUP pin. This bit is not writeable and should always be 1 when read. If a 0 is ever present, an exhausted internal lithium energy source is indicated and both the contents of the RTC data and RAM data are questionable. This bit is unaffected by RESET. 18 BIT 3 0 BIT 2 0 BIT 1 0 BIT 0 0 Bits 6 to 0: Unused. The remaining bits of Register D are not usable. They cannot be written and they always read 0. Maxim Integrated DS12R885/DS12CR887/DS12R887 RTCs with Constant-Voltage Trickle Charger Nonvolatile RAM (NV RAM) The 114 general-purpose NV RAM bytes are not dedicated to any special function within the DS12R885. They can be used by the processor program as battery-backed memory and are fully available during the update cycle. Interrupts The DS12R885 includes three separate, fully automatic sources of interrupt for a processor. The alarm interrupt can be programmed to occur at rates from once per second to once per day. The periodic interrupt can be selected for rates from 500ms to 122s. The updateended interrupt can be used to indicate to the program that an update cycle is complete. Each of these independent interrupt conditions is described in greater detail in other sections of this text. The processor program can select which interrupts, if any, are to be used. Three bits in Register B enable the interrupts. Writing a logic 1 to an interrupt-enable bit permits that interrupt to be initiated when the event occurs. A 0 in an interrupt-enable bit prohibits the IRQ pin from being asserted from that interrupt condition. If an interrupt flag is already set when an interrupt is enabled, IRQ is immediately set at an active level, although the interrupt initiating the event may have occurred earlier. As a result, there are cases where the program should clear such earlier initiated interrupts before first enabling new interrupts. When an interrupt event occurs, the relating flag bit is set to logic 1 in Register C. These flag bits are set independent of the state of the corresponding enable bit in Register B. The flag bit can be used in a polling mode without enabling the corresponding enable bits. The interrupt flag bit is a status bit that software can interrogate as necessary. When a flag is set, an indication is given to software that an interrupt event has occurred since the flag bit was last read; however, care should be taken when using the flag bits as they are cleared each time Register C is read. Double latching is included with Register C so that bits that are set remain stable throughout the read cycle. All bits that are set (high) are cleared when read, and new interrupts that are pending during the read cycle are held until after the cycle is completed. One, two, or three bits can be set when reading Register C. Each used flag bit should be examined when Register C is read to ensure that no interrupts are lost. Maxim Integrated The second flag bit method is used with fully enabled interrupts. When an interrupt flag bit is set and the corresponding interrupt-enable bit is also set, the IRQ pin is asserted low. IRQ is asserted as long as at least one of the three interrupt sources has its flag and enable bits set. The IRQF bit in Register C is a 1 whenever the IRQ pin is driven low. Determination that the RTC initiated an interrupt is accomplished by reading Register C. A logic 1 in bit 7 (IRQF bit) indicates that one or more interrupts have been initiated by the DS12R885. The act of reading Register C clears all active flag bits and the IRQF bit. Oscillator Control Bits When the DS12R887 and DS12CR887 are shipped from the factory, the internal oscillator is turned off. This feature prevents the lithium energy cell from being used until it is installed in a system. A pattern of 010 in bits 4 to 6 of Register A turns the oscillator on and enables the countdown chain. A pattern of 11x (DV2 = 1, DV1 = 1, DV0 = X) turns the oscillator on, but holds the countdown chain of the oscillator in reset. All other combinations of bits 4 to 6 keep the oscillator off. Square-Wave Output Selection Thirteen of the 15 divider taps are made available to a 1of-16 multiplexer, as shown in the functional diagram. The square-wave and periodic-interrupt generators share the output of the multiplexer. The RS0-RS3 bits in Register A establish the output frequency of the multiplexer (see Table 3). Once the frequency is selected, the output of the SQW pin can be turned on and off under program control with the square-wave enable bit, SQWE. Periodic Interrupt Selection The periodic interrupt causes the IRQ pin to go to an active state from once every 500ms to once every 122s. This function is separate from the alarm interrupt, which can be output from once per second to once per day. The periodic interrupt rate is selected using the same Register A bits that select the squarewave frequency (Table 3). Changing the Register A bits affects the square-wave frequency and the periodicinterrupt output. However, each function has a separate enable bit in Register B. The SQWE bit controls the square-wave output. Similarly, the PIE bit in Register B enables the periodic interrupt. The periodic interrupt can be used with software counters to measure inputs, create output intervals, or await the next needed software function. 19 DS12R885/DS12CR887/DS12R887 RTCs with Constant-Voltage Trickle Charger Table 3. Periodic Interrupt Rate and Square-Wave Output Frequency SELECT BITS REGISTER A tPI PERIODIC INTERRUPT RATE SQW OUTPUT FREQUENCY RS3 RS2 RS1 RS0 0 0 0 0 None None 0 0 0 1 3.90625ms 256Hz 0 0 1 0 7.8125ms 128Hz 0 0 1 1 122.070s 8.192kHz 0 1 0 0 244.141s 4.096kHz 0 1 0 1 488.281s 2.048kHz 0 1 1 0 976.5625s 1.024kHz 0 1 1 1 1.953125ms 512Hz 1 0 0 0 3.90625ms 256Hz 1 0 0 1 7.8125ms 128Hz 1 0 1 0 15.625ms 64Hz 1 0 1 1 31.25ms 32Hz 1 1 0 0 62.5ms 16Hz 1 1 0 1 125ms 8Hz 1 1 1 0 250ms 4Hz 1 1 1 1 500ms 2Hz Update Cycle The DS12R885 executes an update cycle once per second regardless of the SET bit in Register B. When the SET bit in Register B is set to 1, the user copy of the double-buffered time, calendar, and alarm bytes is frozen and does not update as the time increments. However, the time countdown chain continues to update the internal copy of the buffer. This feature allows time to maintain accuracy independent of reading or writing the time, calendar, and alarm buffers, and also guarantees that time and calendar information is consistent. The update cycle also compares each alarm byte with the corresponding time byte and issues an alarm if a match or if a don't-care code is present in all three positions. There are three methods that can handle RTC access that avoid any possibility of accessing inconsistent time and calendar data. The first method uses the updateended interrupt. If enabled, an interrupt occurs after every update cycle that indicates over 999ms is available to read valid time and date information. If this interrupt is used, the IRQF bit in Register C should be cleared before leaving the interrupt routine. A second method uses the update-in-progress bit (UIP) in Register A to determine if the update cycle is in progress. The UIP bit pulses once per second. After the UIP bit goes high, the update transfer occurs 244s later. If a low is read on the UIP bit, the user has at least 244s before the time/calendar data is changed. Therefore, the user should avoid interrupt service routines that would cause the time needed to read valid time/calendar data to exceed 244s. The third method uses a periodic interrupt to determine if an update cycle is in progress. The UIP bit in Register A is set high between the setting of the PF bit in Register C (Figure 3). Periodic interrupts that occur at a rate greater than tBUC allow valid time and date information to be reached at each occurrence of the periodic interrupt. The reads should be complete within one (tPI/2 + tBUC) to ensure that data is not read during the update cycle. 1 SECOND UIP tBUC UF tPI/2 tPI/2 PF tPI tBUC = DELAY TIME BEFORE UPDATE CYCLE = 244s Figure 3. UIP and Periodic Interrupt Timing 20 Maxim Integrated DS12R885/DS12CR887/DS12R887 RTCs with Constant-Voltage Trickle Charger Handling, PC Board Layout, and Assembly The EDIP and BGA packages contain a quartz tuningfork crystal. Pick-and-place equipment can be used, but precautions should be taken to ensure that excessive shocks are avoided. Ultrasonic cleaning should be avoided to prevent damage to the crystal. The BGA package can be reflowed as long as the following conditions are met: 1. Preheating (below +160C) is within 90 seconds. 2. Maximum time above +150C is less than 180 seconds. 3. Maximum time above +170C is less than 100 seconds. 4. Maximum time above +200C is less than 60 seconds. 5. Maximum time above +220C is less than 30 seconds. 6. Peak temperature is less than or equal to +225C. Exposure to reflow is limited to two times maximum. Moisture-sensitive packages are shipped from the factory dry-packed. Handling instructions listed on the package label must be followed to prevent damage during reflow. Refer to the IPC/JEDEC J-STD-020 standard for Moisture-Sensitive Device (MSD) classifications. The EDIP (DS12CR887) module can be successfully processed through conventional wave-soldering techniques so long as temperature exposure to the lithium energy source does not exceed +85C. Post-solder cleaning with water-washing techniques is acceptable, provided that ultrasonic vibration is not used. Such cleaning can damage the crystal. Pin Configurations TOP VIEW MOT 1 24 VCC MOT 1 24 VCC X1 2 23 SQW N.C. 2 23 SQW X2 3 22 N.C. N.C. 3 22 N.C. AD0 4 21 RCLR AD0 4 21 N.C. AD1 5 20 VBACKUP AD1 5 AD2 6 DS12R885 19 IRQ AD2 6 AD3 7 18 RESET AD3 7 18 RESET AD4 8 17 DS AD4 8 17 DS AD5 9 16 GND AD5 9 16 N.C. AD6 10 15 R/W AD6 10 15 R/W AD7 11 14 AS AD7 11 14 AS GND 12 13 CS GND 12 13 CS SO (0.300") Maxim Integrated 20 N.C. DS12CR887 19 IRQ EDIP (0.700") 21 DS12R885/DS12CR887/DS12R887 RTCs with Constant-Voltage Trickle Charger Pin Configurations (continued) TOP VIEW (BUMP SIDE DOWN) A DS B VCC C D CS E AD7 GND AD6 DS12R887 AD5 PACKAGE THETA-JA (C/W) THETA-JC (C/W) SO 105 22 Chip Information F 1 RESET VCC R/W Thermal Information TRANSISTOR COUNT: 17,061 PROCESS: CMOS SUBSTRATE CONNECTED TO GROUND GND AD4 2 N.C. VCC AS 3 IRQ Package Information AD3 GND AD2 VCC SQW AD1 GND AD0 4 RCLR VCC MOT GND GND GND 5 VCC VCC VCC GND GND GND VCC VCC VCC GND GND GND VCC VCC VCC GND GND GND 6 For the latest package outline information and land patterns (footprints), go to www.maximintegrated.com/packages. Note that a "+", "#", or "-" in the package code indicates RoHS status only. Package drawings may show a different suffix character, but the drawing pertains to the package regardless of RoHS status. PACKAGE TYPE PACKAGE CODE DOCUMENT NO. 24 SO W24+1 21-0042 24 EDIP MDP24+1 21-0241 48 BGA V48-H1 21-0364 7 8 48 BGA 22 Maxim Integrated DS12R885/DS12CR887/DS12R887 RTCs with Constant-Voltage Trickle Charger Revision History PAGES CHANGED REVISION NUMBER REVISION DATE 0 4/04 Initial release of DS12R885 -- 1 4/04 Added DS12R887 and DS12CR887 to data sheet All 2 12/04 Initial release of DS12R887 All 3 4/06 Corrected Intel Bus Write Timing, Intel Bus Read Timing, IRQ Release Delay Timing, Power-Up/Down Timing, and Functional Diagram diagrams; added the EDIP paragraph to the Handling, PC Board Layout, and Assembly section. 4 5/06 Changed pin 16 from N.C. to GND for the SO package. 5 2/07 Updated 114 bytes bullet in the Features section; updated the Ordering Information; corrected the Intel Bus Read Timing diagram; added a note about how the missing VBACKUP pin on the DS12CR887 and DS12R887 is internally connected to a lithium cell; added the Package Information table. 6 4/10 Updated the storage temperature ranges, added the lead temperature, and updated the soldering temperature for all packages in the Absolute Maximum Ratings; removed the DS12R885 and DS12CR887 leaded parts from the Ordering Information table. 1, 2, 22 7 9/13 Corrected BGA soldering temperature in the Absolute Maximum Ratings and Handling, PC Board Layout, and Assembly section. 1, 2, 21 8 1/15 Updated battery operating temperature range DESCRIPTION 5, 6, 7, 21 10, 21 1, 6, 11, 22 1-4, 7 Maxim Integrated cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim Integrated product. No circuit patent licenses are implied. Maxim Integrated reserves the right to change the circuitry and specifications without notice at any time. The parametric values (min and max limits) shown in the Electrical Characteristics table are guaranteed. Other parametric values quoted in this data sheet are provided for guidance. Maxim Integrated 160 Rio Robles, San Jose, CA 95134 USA 1-408-601-1000 ________________________________ 23 (c) 2015 Maxim Integrated Products, Inc. Maxim Integrated and the Maxim Integrated logo are trademarks of Maxim Integrated Products, Inc.