The GenesysTM
family of programmable power supplies sets a new standard for flexible, reliable,
AC/DC power systems in OEM, Industrial and Laboratory applications.
Features include:
•Highest Power Density available 1500W in 1U
•Wide Range Input 85 - 265Vac Continuous, single phase, 47/63Hz
•Active Power Factor Correction 0.99
•Output up to 600V, Current up to 200A
•Built in RS232/RS485 Interface
•Software Calibration
•Last Setting Memory
•High Resolution 16 bits ADCs & DACs
•Reliable Encoders for Voltage and Current Adjustment
•Constant Voltage/Constant Current auto crossover
•Parallel Operation with Active Current Sharing
•Independent Remote ON/OFF and Remote Enable/Disable
•External Analog Programming and Monitoring
•Reliable Modular and SMT Design
•19" Rack Mounted ATE and OEM applications
•Five Year Warranty
•Optional Isolated Analog Programming and Monitoring
•Optional GPIB (SCPI) Interface
•LabView®drivers (LabView®is registered trademark of National Instruments Corporation )
Worldwide Safety Agency Approvals CE Mark for LVD and EMC Regulation
Test and Measurement
Last setting memory simplifies test design and requires no battery backup.
Built in RS232/RS485 gives maximum system flexibility along with 0-5V and 0-10V, selectable analog programming
Wide range of available inputs allows testing of many different devices.
Semiconductor Burn-in
Safe Start may be enabled to restart at zero output to protect load.
Wide range input (85-265VAC) with Active Power Factor correction rides through input transients easily.
Component Test
High power density, zero stacking and single wire parallel operation give maximum system flexibility
Laser Diode
OVP is directly set on Voltage Meter, assuring accurate protection settings.
Current Limit Fold Back assures load is protected from current surges.
Heater Supplies
Smooth, reliable encoders enhance front panel control.
Remote analog programming is user selectable 0-5V or 0-10V.
RF Amplifiers and Magnets
Robust design assures stable operation under a wide variety of loads.
Excellent linearity in voltage and current mode.
Applications
Genesysâ„¢ power supplies have been designed to meet the demands of a wide variety of applications.
Genesysâ„¢
750W/1500W-1U
1|
1. Remote/Local Output Voltage Sense Connections
2. DIP Switches select 0-5V or 0-10V Programming and other functions.
3. DB25 (Female) connector allows (Non-isolated) Analog Program and Monitor as well as other functions.
4. RS485 Out to other Genesys Power Supplies
5. RS232/RS485 IN Remote Serial Programming
6. Output Terminals are rugged bus bars for 6-60V Output, higher output voltage models have terminal block connector.
7. Exit air assures reliable operation when zero stacked
8. Wide-Range Input 85-265VAC continuous, 47/63Hz with Active Power Factor Correction (0.99)
AC Input Connector 750W: IEC320, 1500W: Screw terminal Model Shown
9. Position for Optional Isolated Analog Programming or GPIB Digital Interface model shown
Front Panel Description
Rear Panel Description
1. AC On/Off
2. Air Intake allows zero stacking for maximum system flexibility and power density
3. Reliable encoder controls Output Voltage and sets Address.
4. Volt Meter shows Output Voltage and directly displays OVP, UVL and Address settings.
5. Amp Meter also displays baud rate.
6. Reliable encoder controls Output Current and sets baud rate.
7. Function/Status LED's
8. Pushbuttons allow flexible user configuration
Coarse and Fine Voltage and Current Adjustment of Output
Preview Settings and Set Voltage while in Current Mode or with Output OFF
Set OVP and UVL Limits
Set Current Foldback
Local/Remote Mode and select Address and Baud Rate
Output ON/OFF and Auto Start/Safe Start Mode
•Alarm
•Fine Control
•Preview Settings
•Foldback Mode
•Remote Mode
•Output On
|2
Genesys
â„¢
750W/1500W Specifications
Genesysâ„¢
750W/1500W-1U
3|
*1: Minimum voltage is guaranteed to maximum 0.2% of Vomax.
*2: Minimum current is guaranteed to maximum 0.4% of Iomax.
2.Display
3.Indications
Voltage
Current
Voltage, Current, Alarm, Fine, Preview, Foldback, Local, Output On
4 digits , accuracy: 0.5%+/-1 count
4 digits, accuracy: 0.5%+/-1 count X
X
X
X
X
X
1.5 FRONT PANEL
1.Control functions Vout/ Iout manual adjust by separate encoders (coarse and fine adjustment selectable)
OVP/UVL manual adjust by Volt. Adjust encoder
Address selection by Voltage (or current) adjust encoder. No of addresses:31
AC on/off, Output on/off, Re-start modes (auto, safe), Foldback control (CV to CC), Go to local control
RS232/485 and IEEE488.2 selection by IEEE enable switch and DIP switch
Baud rate selection: 1200,2400,4800,9600 and 19,200 bps
X
X
X
X
X
X
X
X
X
X
X
X
OVP Programming
Resolution (0.1% of Vomax)
Accuracy (1% of Vomax) mV
mV X
XX
X
Readback Current
Resolution (0.012% of Iomax )
Accuracy (0.1% of Iomax+0.3% of Io Actual Output)
Resolution (0.012% of Iomax )
Accuracy (0.1% of Iomax+0.3% of Io Actual Output)
mA
mA
mA
mA
12
400
24
800
10.8
360
21.6
720
7.2
240
14.4
480
4.56
152
9.12
304
3.0
100
6
200
2.28
76
4.56
152
1.50
50
3.0
100
1.14
38
2.28
76
0.9
30
1.80
60
0.60
20
1.20
40
0.30
10
0.60
20
0.16
5.2
0.32
10.4
X
XX
X
Readback Voltage
Resolution (0.012% of Vomax)
Accuracy (0.1%Vomax+0.1% of Vo Actual Output) mV
mV 0.72
12 0.96
16 1.50
25 2.40
40 3.60
60 4.80
80 7.2
120 9.6
160 12
200 18
300 36
600 72
1200 X
XX
X
Remote Current Programming (16 bit)
Resolution (0.012% of Iomax)
Accuracy (0.05% of Iomax+0.05% of Io Actual Output)
Resolution (0.012% of Iomax)
Accuracy (0.05% of Iomax+0.05% of Io Actual Output)
mA
mA
mA
mA
12
10
24
20
10.8
9
21.6
18
7.2
6
14.4
12
4.56
3.8
9.12
7.6
3.0
2.5
6
5
2.28
1.9
4.56
3.8
1.50
1.25
3.0
2.5
1.14
0.95
2.28
1.9
0.90
0.75
1.80
1.50
0.60
0.5
1.20
1
0.30
0.25
0.60
0.5
0.16
0.13
0.32
0.26
X
XX
X
1.6 Interface RS232&RS485 or Optional GPIB Interface
Model
Remote Voltage Programming (16 bit)
Resolution (0.012% of Vomax)
Accuracy (0.05%Vomax+0.05% of Vo Actual Output)
V
mV
mV
6
0.72
6.0
8
0.96
8.0
12.5
1.50
12.5
20
2.40
20
30
3.60
30
40
4.80
40
60
7.2
60
80
9.6
80
100
12
100
150
18
150
300
36
300
600
72
600
750W
X
X
1500W
X
X
XX
6
60 8
80 12
125 20
200 29
300 39
400 59
600 78
800 98
1000 146
1500 293
3000 586
6000
1.4 ANALOG PROGRAMMING AND MONITORING
1.Vout Voltage Programming
2.Iout Voltage Programming
3.Vout Resistor Programming
4.Iout Resistor Programming
5.On/Off control (rear panel)
6.Output Current monitor
7.Output Voltage monitor
8.Power Supply OK signal
9. CV/CC indicator
10. Enable/Disable
0~100%, 0~5V or 0~10V, user select. Accuracy and linearity:+/-0.5% of rated Vout.
0~100%, 0~5V or 0~10V, user select. Accuracy and linearity:+/-1% of rated Iout.
0~100%, 0~5/10Kohm full scale,user select.,Accuracy and linearity:+/-1% of rated Vout.
0~100%, 0~5/10Kohm full scale,user select. Accuracy and linearity:+/-1.5% of rated Iout.
By electrical. Voltage: 0~0.6V/2~15V,or dry contact ,user selectable logic
0~5V or 0~10V , accuracy:1% , user selectable
0~5V or 0~10V ,accuracy:1% ,user selectable
5V-OK, 0V-Fail 500ohm impedance
CV: TTL high (4~5V) source: 10mA, CC: TTL low (0~0.4V):10mA
Dry contact. Open:off , Short: on. Max. voltage at Enable/Disable in: 6V
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
1.1 CONSTANT VOLTAGE MODE
1.Max.line regulation ( 0.01% of Vo+ 2mV )(*4)
2.Max load regulation ( 0.01% of Vo+2mV )(*5)
3.Ripple and noise p-p 20MHz
4.Ripple r.m.s 5Hz~1MHz
5.Remote sense compensation/line
6.Temp. coefficient
7.Up-prog. response time, 0~Vomax
8.Down-prog response time full-load
9.Down-prog response time no-load
10.Transient response time (*8)
mV
mV
mV
mV
V
PPM/°C
mS
mS
mS
2.6
2.6
60
8
1
100PPM/°C from rated output voltage,following 30 minutes warm up
80mS , N.L/F.L , resistive load
10
500
Less than 1mSec for models up to and including 100V. 2msec for models above 100V
2.8
2.8
60
8
1
600
3.3
3.3
60
8
1
50
700
4
4
60
8
1
800
5
5
60
8
1.5
900
6
6
60
8
2
80
1000
8
8
60
8
3
1100
10
10
80
8
4
150mS , N.L/F.L , resistive load
1200
12
12
80
8
5
1500
17
17
100
10
5
150
2000
32
32
125
25
5
2500
62
62
300
60
5
4000
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
1.2 CONSTANT CURRENT MODE
1.Max.line regulation (0.01% of Io+ 2mA)(*4)
2.Max.load regulation (0.01% of Io+5mA)(*6)
3.Ripple r.m.s 5Hz~1MHz . (*7)
1.Max.line regulation (0.01% of Io+ 2mA)(*4)
2.Max.load regulation (0.01% of Io+5mA)(*6)
3.Ripple r.m.s 5Hz~1MHz .(*7)
4.Temp. coefficient
mA
mA
mA
mA
mA
mA
PPM/°C
12
15
200
2
5
400
100PPM/°C from rated output voltage,following 30 minutes warm up
11
14
180
2
5
360
8
11
120
2
5
240
5.8
8.8
76
2
5
152
4.5
7.5
63
2
5
125
3.9
6.9
48
2
5
95
3.25
6.25
38
2
5
75
2.95
5.95
29
2
5
57
2.75
5.75
23
2
5
45
2.5
5.5
18
2
5
35
2.25
5.25
13
2
5
25
2.13
5.13
8
2
5
12
X
X
X
X
X
X
X
X
1.3 PROTECTIVE FUNCTIONS
1. OCP
2. OCP Foldback
3. OVP type
4. OVP trip point
5. Over Temp. Protection
0~105% Constant Current
Output shut down when power supply change from CV to CC. User selectable.
Inverter shut-down, manual reset by AC input recycle or by OUT button
0.5~7.5V
User selectable , latched or non latched
0.5~10V 1~15V 1~24V 2~36V 2~44V 5~66V 5~88V 5~110V 5~165V 5~330V 5~660V
X
X
X
X
X
X
X
X
X
X
*7: For 6V models the ripple is measured at 2~6V output voltage and full output current. For other models, the ripple is measured at 10~100% output voltage and full output current.
*8: Time for the output voltage to recover within 0.5% of its rated for a load change 10~90% of rated output , Output set-point:10~100%.
*3: At maximum output power.
*4: 85~132Vac or 170~265Vac, constant load. *5: From No-load to Full-load, constant input voltage.
*6: For load voltage change, equal to the unit voltage rating, constant input voltage.
GEN
V
A
W
6-100
6
100
600
8-90
8
90
720
12.5-60
12.5
60
750
20-38
20
38
760
30-25
30
25
750
40-19
40
19
760
60-12.5
60
12.5
750
80-9.5
80
9.5
760
100-7.5
100
7.5
750
150-5
150
5
750
300-2.5
300
2.5
750
600-1.3
600
1.3
780
X
X
X
X
1.0 MODEL
1.Rated output voltage (*1)
2.Rated Output Current (*2)
3.Rated Output Power
750W 1500W
3.Rated Output Power
1.0 MODEL
1.Rated output voltage(*1)
2.Rated Output Current(*2)
4.Efficiency at 100/200Vac (*3)
GEN
V
A
W
%
6-200
6
200
1200
77/80
8-180
8
180
1440
78/81
12.5-120
12.5
120
1500
81/84
20-76
20
76
1520
83/86
30-50
30
50
1500
83/86
40-38
40
38
1520
84/88
60-25
60
25
1500
84/88
80-19
80
19
1520
84/88
100-15
100
15
1500
84/88
150-10
150
10
1500
84/88
300-5
300
5
1500
83/87
600-2.6
600
2.6
1560
83/87 X
X
X
X
X
X
Accuracy -Values have been calculated at Vomax & Io max
General Specifications Genesysâ„¢ 750W/1500W
Outline Drawing Genesysâ„¢ 750W/1500W Units
|4
NOTE
1. PLUG CONNECTORS INCLUDED WITH THE POWER SUPPLY
2. CHASSIS SLIDES MOUNTING HOLES #10-32 MARKED "A"
GENERAL DEVICES P/N: CC301-00-S160 OR EQUIVALENT
*1: For cases where conformance to various safety standards (UL, IEC etc.) is required, to be described as 100-240Vac (50/60Hz).
2.1 INPUT CHARACTERISTICS
1. Input voltage/freq. (*1)
2. Power Factor 0.99 @100/200Vac, rated output power.
3. EN61000-3-2,3 compliance Complies with EN61000-3-2 class A and EN61000-3-3 at 20~100% output power.
4. Input current 100/200Vac
5. Inrush current 100/200Vac 750W :Less than 25A, 1500W :Less than 50A
6. Hold-up time More than 20mS , 100Vac , at 100% load.
750W :10.5A / 5A, 1500W :21A / 11A
85~265Vac continuous, 47~63Hz, single phase
2.6 MECHANICAL CONSTRUCTION
1. Cooling
2. Dimensions (WxHxD) W: 422.8mm, H: 43.6mm, D: 432.8mm (excluding connectors, encoders, handles etc..)
3. Weight 750W: 7Kg (15.4 Lbs) 1500W: 8.5Kg (18.7 Lbs)
4. AC Input connector 750W: AC Inlet IEC320.
1500W: screw terminal block, Phoenix P/N: FRONT-4-H-7.62 , with strain relief
5.Output connectors 6V to 60V models: bus-bars (hole Ø 8.5mm). 80V to 600V models :terminal block ,Phoenix P/N: FRONT-4-H-7.62
Forced air flow: from front to rear. No ventilation holes at the top or bottom of the chassis Variable fan speed.
2.7 RELIABILITY SPECS
1. Warranty 5 years.
1. Parallel Operation
2. Series Operation Up to 4 units in master/slave mode with single wire current balance connection
Up to 2 units. with external diodes. 600V Max to Chassis ground
2.2 POWER SUPPLY CONFIGURATION
2.3 ENVIRONMENTAL CONDITIONS
1. Operating temp
2. Storage temp -20~70°C
3. Operating humidity 30~90% RH (no condensation).
4. Storage humidity 10~95% RH (no condensation).
5. Vibration MIL-810E, method 514.4 , test cond. I-3.3.1 . The EUT is fixed to the vibrating surface.
6. Shock Less than 20G , half sine , 11mSec. Unit is unpacked.
7. Altitude Operating: 10000ft (3000m) , Non operating: 40000ft (12000m).
0~50 °C, 100% load.
EN55022A, FCC part 15-A, VCCI-1.
2.4 EMC
1.Applicable standards: EN55024
2.ESD IEC1000-4-2. Air-disch.-8KV, contact disch.-4KV
3.Fast transients IEC1000-4-4. 2KV
4.Surge immunity IEC1000-4-5. 1KV line to line, 2KV line to ground
5.Conducted immunity IEC1000-4-6, 3V
6.Radiated immunity IEC1000-4-3, 3V/m
7.Conducted emission EN55022B,FCC part 15J-B,VCCI-2
8.Radiated emission EN55022A,FCC part 15-A,VCCI-1
9.Voltage dips EN61000-4-11
10. Conducted emission
11. Radiated emission EN55022B, FCC part 15-B, VCCI-2.
More than 100Mohm at 25°C , 70% RH.
2.5 SAFETY
1.Applicable standards:
400<Vout<600V:Output is hazardous, IEEE/Isolated analog are not SELV.
2.Withstand voltage 60<Vout<600V models: Input-Haz. Output: 2.5KVrms 1min, Input-SELV: 3KVrms 1min.
Hazardous Output.-SELV: 1.9KVrms 1min, Hazardous Output-Ground:1.9KVrms 1min.
3.Insulation resistance
CE Mark, UL60950,EN60950 listed. Vout<60V:Output is SELV , IEEE/Isolated analog are SELV.
60<Vout<400V: Output is hazardous, IEEE/Isolated analog are SELV.
Vout<60V models :Input-Outputs (SELV): 3.0KVrms 1min, Input-Ground: 2.0KVrms 1min.
Input-Ground: 2KVrms 1min.
Genesysâ„¢ Power Parallel and Series Configurations
Parallel operation - Master/ Slave:
Active current sharing allows up to 4 units to be connected in an auto
parallel configuration for four times the output power.
Series operation
Up to two units may be connected in series to increase the output
voltage or to provide bipolar output. (Max 600V to Chassis Ground)
Remote Programming via RS232&RS485 Interface
Standard Serial Interface allows chain control of up to 31 power
supplies on the same bus with built in RS232&485 Interface
Programming Options (Factory installed)
Digital Programming via IEEE Interface P/N: IEEE
•IEEE 488.2 Compliant •SCPI Compliant
•Program Voltage •Program Current
•Measure Voltage •Measure Current
•Over Voltage setting and shutdown •Current Foldback shutdown
•Error and Status Messages
Isolated Analog Programming
Four Channels to Program and Monitor Voltage and Current
Isolation allows operation with floating references and difficult electrical environments.
Choose between programming with Voltage or Current.
Connection via Removable terminal block P/N: Phoenix MC1,5/8-ST-3.81
P/N: IS510 - Voltage Programming, user selectable 0-5V or 0-10V signal
Power supply Voltage and Current Programming accuracy +/-1%
Power supply Voltage and Current Monitoring accuracy +/-1.5%
P/N: IS420 - Current Programming with 4-20mA signal
Power supply Voltage and Current Programming accuracy +/-1%
Power supply Voltage and Current Monitoring accuracy +/-1.5%
Genesysâ„¢
750W/1500W-1U
5|
Power Supply Identification / Accessories
Accessories
1.Communication cable
RS232/RS485 Cable is used to connect the power supply to the PC Controller
Factory option P/N
RS232/485 Interface built in Standard -
GPIB Interface IEEE
Voltage Programming Isolated analog interface IS510
Current Programming Isolated analog interface IS420
AC Cords sets (750W only)
How to order
Europe
750W
10A/250 Vac L=2m
INT'L 7/VII
IEC320-C13
P/N: GEN/E
Japan
750W
13A/125 Vac L=2m
IEC320-C13
P/N: GEN/J
Middle East
750W
10A/250 Vac L=2m
SI-32
IEC320-C13
P/N: GEN/I
North America
750W
13A/125 Vac L=2m
NEMA 5-15P
IEC320-C13
P/N : GEN/U
Region
Output Power
AC Cords
Wall Plug
Power Supply
Connector
Part Number
Models 750/1500W
Serial link cable*
Chaining Power Supply to Power Supply up to 31 GEN units
|6
-
GEN
Series
Name
600
Output
Voltage
(0~600V)
2.6
Output
Current
(0~2.6A)
-
IEEE
IS510
IS420
Option:
-
E - Europe
J - Japan
I - Middle East
U- North America
Region:
Factory Options AC Cable option is 750W only
Mode
RS485 Power Supply Connector Communication Cable
EIA/TIA-568A (RJ-45) Shield Ground L=50cm GEN/RJ45
P/N
* Included with the power supply
Mode
P/N
RS485 RS232 RS232
GEN/485-9 GEN/232-9 GEN/232-25
PC Connector
Communication Cable
Power Supply Connector
DB-9F
Shield Ground L=2m
EIA/TIA-568A (RJ-45)
DB-9F
Shield Ground L=2m
EIA/TIA-568A (RJ-45)
DB-25F
FShield Ground L=2m
EIA/TIA-568A (RJ-45)
Model
GEN60-12.5
GEN60-25
GEN80-9.5
GEN80-19
GEN100-7.5
GEN100-15
GEN150-5
GEN150-10
GEN300-2.5
GEN300-5
GEN600-1.3
GEN600-2.6
Output
Power
( W )
750
1500
760
1520
750
1500
750
1500
750
1500
780
1560
Output
Voltage
VDC
0~60V
0~80V
0~100V
0~150V
0~300V
0~600V
Output
Current
( A )
0~12.5
0~25
0~9.5
0~19
0~7.5
0~15
0~5
0~10
0~2.5
0~5
0~1.3
0~2.6
Output
Power
( W )
600
1200
720
1440
750
1500
760
1520
750
1500
760
1520
Output
Current
( A )
0~100
0~200
0~90
0~180
0~60
0~120
0~38
0~76
0~25
0~50
0~19
0~38
Output
Voltage
VDC
0~6V
0~8V
0~12.5V
0~20V
0~30V
0~40V
Model
GEN6-100
GEN6-200
GEN8-90
GEN8-180
GEN12.5-60
GEN12.5-120
GEN20-38
GEN20-76
GEN30-25
GEN30-50
GEN40-19
GEN40-38