PS3X Series Switching Power Supplies Features * * * * Compact size Universal AC input voltage 5V, 12V, and 24V DC outputs Available with mounting brackets for direct or DIN rail mounting * Overcurrent/overvoltage protection * EMC, EN55022 Class B compliant * UL/c-UL recognized, TUV 95 95 82 50.8 50.8 28 PS3X-B (15W) 28.5 PS3X-C (25W) 159 129 99 79 62 38 35 PS3X-D (50W) 38 PS3X-Q (75W) PS3X-E (100W) Part Numbers L-shaped Mounting Bracket (optional) Power Supply Apperance Output Capacity 15W Part Number Input Voltage Output Voltage 5V 12V 24V PS3X-B05AFC PS3X-B12AFC PS3X-B24AFC Output Current Applicable Power Supply Part Number PS3X-B PS9Z-3N3A 3.0A 1.3A 0.63A PS3X-C PS9Z-3N3B PS3X-D PS9Z-3E3B PS3X-Q PS9Z-3N3E PS3X-E 25W 5V 12V 24V PS3X-C05AFC PS3X-C12AFC PS3X-C24AFC 5.0A 2.1A 1.1A DIN-rail Mounting Bracket (optional) Applicable Power Supply Part Number PS3X-B PS9Z-3N4B PS3X-C 50W 12V 24V PS3X-D12AFG PS3X-D24AFG PS3X-D 4.2A 2.2A 100 to 240V AC Appearance 75W PS9Z-3E4D PS3X-E DIN Rail 5V 12V 24V PS3X-Q05AFG PS3X-Q12AFG PS3X-Q24AFG PS9Z-3E4C PS3X-Q 12.0A 6.0A 3.2A Part Number Length Material Weight (g) BNDN1000 1000mm Aluminum 200 End Clips Appearance 100W 5V 12V 24V PS3X-E05AFG PS3X-E12AFG PS3X-E24AFG 16.0A 8.5A 4.5A Part Number BNL5 small DIN rail end clip BNL6 medium DIN rail end clip (the BNL6 has a higher profile than BNL5) Part Number Configuration PS3X - B 05 AF C Output Capacity B: 15W C: 25W D: 50W Q: 75W E: 100W Output Voltage 05: 5V DC (15W, 25W, 75W, 100W) 12: 12V DC 24: 24V DC Cover and Terminal Style C: w/Standard cover, Horizontal terminal block (PS3X-B/C models) G: w/Standard cover, Vertical terminal block (PS3X-D/Q/E models) Input Voltage AF: 100 to 240V AC Description www.IDEC.com/powersupply Specifications Power Supplies Description [15W] PS3X-B05/B12/B24 [25W] PS3X-C05/C12/C24 [50W] PS3X-D12/D24 Rated Input Voltage 88 to 264V AC / 125 to 375V DC Frequency 47 to 63 Hz Input Current Inrush Current (Ta = -25C, ACV cold start) 0.5A max. 0.65A max. 1.3A max. 1.8A max. 2.5A max. at 115V AC 40A max. 30A max. 30A max. 30A max. 35A max. at 230V AC 60A max. 50A max. 50A max. 50A max. 70A max. 0.5mA max. 1.5mA max. 1.5mA max. 1.5mA max. 1.5mA max. 77% 77% -- 77% 77% 81% 81% 81% 82% 81% 82% 84% 84% 84% 84% 5V, 3A 5V, 5A -- 5V, 12A 5V, 16A 12V, 1.3A 12V, 2.1A 12V, 4.2A 12V, 6A 12V, 8.5A 24V, 0.63A 24V, 1.1A 24V, 2.2A 24V, 3.2A 24V, 4.5A Leakage Current 5V Efficiency (Typ.) (230V AC at input/rated 12V output) 24V Rated Voltage/Current Adjustable Voltage Range Output Holding Time 10% 13 ms typ. (100V AC) 10 ms typ. (100V AC) 23 ms typ. (100V AC) 14 ms typ. (100V AC) 17 ms typ. (100V AC) 60 ms minimum (230V AC) 60 ms minimum (230V AC) 60 ms minimum (230V AC) 60 ms minimum (230V AC) 80 ms minimum (230V AC) Start Time 1000 ms max. (230V AC input, rated output) 50 ms max. (230V AC input, rated output) Rise Time 30 ms max. (230V AC input, rated output) Input Fluctuation Output Dielectric Strength Supplementary Functions Ripple (including noise) Regulation Temperature Fluctuation 0.04% / C max. (-20 to +50C) -20 to -10C 5V: 200mV max. 12V/24V: 200mV max. -10 to 0C 5V: 160mV max. 12V/24V: 200mV max. 5V: 140mV max. 12V: 240mV max. 24V: 300mV max. PS3X-B, C: 0 to +50C PS3X-D, Q, E: 0 to +45C 5V: 100mV max. 12V/24V: 150mV max. 5V: 70mV max. 12V: 120mV max. 24V: 150mV max. - - - 12V: 240mV max. 24V: 300mV max. 5V: 140mV max. 12V: 240mV max. 24V: 300mV max. 5V: 160mV max. 12V: 240mV max. 24V: 300mV max. 5V: 70mV max. 12V: 120mV max. 24V: 150mV max. 5V: 100mV max. 12V: 120mV max. 24V: 150mV max. 12V: 120mV max. 24V: 150mV max. 105% min. (auto reset) (Note 2) Voltage limitation at 115% min. Intermittent operation or output off at 115% min. (Note 3) Operation Indicator green LED Between input and output terminals 3000V AC, 1 minute Between input and ground terminals 2000V AC, 1 minute Between output and ground terminals 500V DC, 1 minute 100M minimum, 500V DC megger (between input and output terminals, between input and ground terminals) Insulation Resistance -20 to +70C (no freezing, see output derating) Operating Temperature Operating Humidity -10 to +70C (no freezing, see output derating) 20 to 85% RH (no condensation) Storage Temperature -40 to +85C (no freezing) Storage Humidity 10 to 95% RH (no condensation) 10 to 55 Hz, 20m/s2 constant, 2 hours each in 3 axes Vibration Resistance 200m/s2, 1 shock each in 3 axes Shock Resistance EMI EN55022 Class B EMS EN55024 Safety Standards Dimensions (H x W x D) (mm) Terminal Screw 30 ms max. (230V AC input, rated output) 0.04% / C max. (-10 to +45C) Overcurrent Protection Weight (approx.) 30 ms max. (230V AC input, rated output) 5V: 2% max. 12V, 24V: 1% max. 5V: 140mV max. 12V: 240mV max. 24V: 300mV max. Overvoltage Protection 30 ms max. (230V AC input, rated output) 0.5% max. Overvoltage Fluctuation EMC [100W] PS3X-E05/E12/E24 100 to 240V AC 85 to 264V AC/ 120 to 375V DC Voltage Range (Note 1) Input [75W] PS3X-Q05/Q12/Q24 IEC/EN60950-1, UL60950-1, CSA C22.2 No. 60950-1 50.8H x 28W x 62D 50.8H x 28.5W x 79D 82H x 35W x 99D 95H x 38W x 129D 95H x 38W x 159D 130g 180g 340g 500g 700g M3 M3.5 Note 1: See "Output Current vs. Input Voltage" characteristics next page. Not subject to safety standards. When using DC input, connect a fuse to the input terminal for DC input protection. Note 2: Overload for 30 seconds or longer may damage the internal elements. Note 3: One minute after the output has been turned off, turn on the AC input again. Characteristics Operating Temperature vs. Output Current (Derating Curves) Conditions: Natural air cooling (operating temperature is the temperature around the power supply) PS3X PS3X-D/Q/E 80 80 80 70 60 50 70 60 50 40 37.5 30 40 30 20 10 20 10 0 -30 -20 -10 0 10 20 30 40 50 60 0 -10 70 Operating Temperature (C) 0 10 20 30 40 50 60 100 70 60 50 40 30 20 10 0 -10 70 Intermittent Operation 90 Output Current (%) 100 90 Output Current (%) 100 90 Output Current (%) 100 Output Voltage (%) PS3X-B/C Overcurrent Protection Characteristics Operating Temperature (C) 0 0 20 30Output 40 50 60 (%) 70 Current Operating Temperature (C) 0 10 Output Current vs. Input Voltage (TA = 25C) PS3X-D/Q/E 100 100 90 90 90 80 80 80 70 60 50 40 30 20 10 0 PS3X-B: 85 100 PS3X-C: 88 100 Output Current (%) 100 Output Current (%) Output Current (%) PS3X-B/C 70 60 50 40 30 20 10 Input Voltage (VAC) 264 264 0 88 100 264 Input Voltage (VAC) Up UL/EN60950-1 Mounting A, B PS3X-B05, -B12, -B24 PS3X-C05, -C12, -C24 50C PS3X-D12, -D24 PS3X-Q05, -Q12, -Q24 PS3X-E05, -E12, -E24 45C Mounting A (standard) Note: Observe the derating curves when operating PS3X power supplies. 60 50 40 30 800.262.4332 20 10 Operating Temperature by Safety Standards Power Supplies 70 Mounting B 0 88 176 Input Voltage (VAC) 132 264 100 105 800-262-IDEC (4332) Dimensions (mm) Output Voltage Adjustment LED 5-M3 (Terminal Screw) Output Voltage 11.0 Adjustment 2-M3 (Depth 2.5 to 4.0 mm max.) 11.4 Output Voltage Adjustment 14.5 82.0 74.0 99.0 79.0 2-M3 (Depth 2.5 to 4.0 mm max.) 2-M3 (Depth 2.5 to 4.0 mm max.) 95.0 32.0 2-M3 (Depth 2.5 to 4.0 mm max.) 10.0 19.0 38.0 118.0 18.0 22.0 159.0 3-M3 (Depth 2.5 to 4.0 mm max.) 10.5 19.5 162.6 78.0 LED Output Voltage Adjustment 77.0 129.0 3-M3 (Depth 2.5 to 4.0 mm max.) 24.0 7-M3.5 (Terminal Screw) 2-M3 (Depth 2.5 to 4.0 mm max.) 18.0 38.0 LED 5-M3 (Terminal Screw) Output Voltage 32.0 Adjustment 34.0 ) 9.5 (Terminal Centers) Terminal Cover 129.3 33.0 78.0 95.0 Terminal Cover 18.0 PS3X-E 9.5 (Terminal Centers) PS3X-Q 5-M3 (Terminal Screw) 65.0 15.1 62.0 2-M3 (Depth 2.5 to 4.0 mm max.) LED 2-M3 (Depth 2.5 to 4.0 mm max.) 28 39.1 2-M3 (Depth 2.5 to 4.0 mm max.) 17.5 5-M3 (Terminal Screw) 25.4 25.25 LED 99.7 55.0 20.5 45.5 Terminal Cover 91.9 55.0 35.0 13.0 50.8 Terminal Cover 50.8 8.25 76.0 39.1 28.5 Terminal Cover PS3X-D 9.5 (Terminal Centers) PS3X-C 7.62 (Terminal Centers) 7.62 (Terminal Centers) PS3X-B Terminal Markings PS3X-B/C PS3X-D/Q PS3X-E L N -V L L N N -V V -V +V V.ADJ LED V.ADJ LED +V V.ADJ LED 800.262.4332 Marking Name Description L, N AC Input Terminal Accepts a wide range of voltage and frequency. Polarity does not matter when using DC input. Ground Terminal Be sure to connect this terminal to a proper ground. +V, -V DC Output Terminals Positive and negative output terminals V.ADJ Output Voltage Adjustment Allows adjustment within 10%. Turning clockwise increases the output voltage. LED Power status Illuminates (green) when input power is applied. www.IDEC.com/powersupply L-shaped Mounting Bracket PS9Z-3N3A (for 15W) PS9Z-3N3B (for 25W) 41 4-o3.5 holes 800.262.4332 65.0 83.5 0.5 20.0 o3 .5 ho 6.5 3.5 2- 4o3 .5 28.0 17.5 27.0 13.5 2.3 20.0 10.0 6.5 les 4.0 ho les PS9Z-3N3E (for 75W/100W) 3-o4.5 holes 4-o3.5 holes 118.0 25.0 77.0 4.5 ho le s 22.5 28.0 2.0 28.0 17.5 .5 15.0 10.0 o3 7.5 42.5 100.0 0.3 157.5 7.0 6.5 2.3 18.0 4-o4.5 holes 18.0 34.5 12.5 15.5 31.0 13.5 3-o3.5 holes 0.2 PS9Z-3E3B (for 50W) 22.0 10.0 2.0 72.0 74.0 0.3 80.0 0.3 103.0 4-o3.5 holes 16.5 20.0 27.0 14 39.1 30.0 14.0 26 3.5 x 4.5 oblong hole 2-C2.0 10.0 H1 DIN-rail Mounting Bracket H2 H3 35 Part Number L3 PS9Z-3N4B PS9Z-3E4C L1 PS9Z-3E4D L2 Applicable Power Supply L1 L2 L3 H1 H2 H3 PS3X-B 95 105.5 35 5.2 20.5 50.8 PS3X-C 95 113 35 5.2 20.5 50.8 PS3X-D 136 117* 35 5.2 20.5 82 PS3X-Q 188 141* 39.5 5.2 19.7 95 PS3X-E 188 173* 39.5 5.2 19.7 95 * Note that L2 is shorter than L1. Instructions Installation Notes 111 When mounting the PS3X switching power supply, see the figure on the right. 333 Use M3 screws for mounting. Choose screws that protrude 2.5 to 4mm from the surface of the switching power supply. Mounting A (standard) 2.5 to 4 mm 222 See dimension drawings for mounting hole layouts. Up 444 Do not cover the openings of the switching power supply. Ensure proper heat dissipation by convection. Mounting B Chassis Mounting Screw Mounting Panel 555 Maintain a minimum of 20mm clearance around the power supply. 666 When derating of the output does not work, provide forced air-cooling. 777 Make sure to wire the ground terminal correctly. 888 For wiring, use wires with heat resistance of 60C or higher. Use copper wire. 999 Recommended tightening torque of terminal screws: 0.8 N*m Adjustment of Output Voltage The output voltage can be adjusted within 10% of the rated output voltage by using the V.ADJ control. Turning the V.ADJ clockwise increases the output voltage. Turning counterclockwise decreases the output voltage. Note that overvoltage protection may work when increasing the output voltage. Overcurrent Protection The output voltage drops automatically when an overcurrent flows, resulting in intermittent operation. Normal voltage is automatically restored when the load returns to normal conditions. However, overcurrent for a prolonged period of time or short-circuit causes the internal elements to deteriorate or break down. Overvoltage Protection PS3X-B/C: Voltage limit and auto-recovery method. The switching power supplies operate normally when voltage returns to normal. PS3X-D/Q/E: The output is turned off when an overvoltage is applied. When the output voltage has dropped due to an overvoltage, turn the input off, and after one minute, turn the input on again. Series Operation When connecting two switching power supplies in a series, insert a Schottky diode to each output. Parallel Operation Parallel operation is not possible. Insulation/Dielectric Test When performing an insulation/dielectric test, short the input (between AC) and output (between + and -). Do not apply or interrupt the voltage suddenly, otherwise surge voltage may be generated and the power supply may be damaged. Safety Precautions ** Do not use switching power supplies with equipment where failure or inadvertent operation may harm anyone, such as medical, aerospace, railway, nuclear, etc. PS3X switching power supplies are designed for use in general electric equipment such as office, communication, measuring, and industrial electric devices. ** Do not disassemble, repair, or modify the power supplies, otherwise electric shock, fire, or failure may occur. ** Do not install the switching power supply in places where someone will touch it when input voltage is applied. Do not touch the switching power supply while input voltage is applied and right after the power is turned off, because high temperature and high voltage may cause burns and electric shocks. ** Do not short circuit the output terminals or output lead wires, otherwise fire or damage may occur. ** Provide the final product with protection against failure or damage that may be caused by malfunction of the switching power supply. Damaged switching power supply may cause overvoltage on the output terminals, or may cause voltage drop. ** Do not touch the inside of the switching power supply, and make sure that foreign objects do not enter the switching power supply, otherwise an accident or failure may occur. ** Observe the temperature derating curves. Operating temperature refers to the temperature around the lower part of the switching power supply. Failure to observe the derating curves could result in an internal temperature rise and possible failure of the switching power supply. ** The fuse inside the switching power supply is for AC input. When using with DC input, install an external fuse. ** Do not set the V. ADJ control over the setting range, otherwise performance deterioration or failure may occur. ** When failure or error occurs, shut down the input to the switching power supply, and contact IDEC. ** Do not use or store the switching power supply in a place subject to extreme vibration or shocks, otherwise failure will result. ** Do not use the switching power supply where it is subject to or near: -- Direct sunlight, heat or high temperatures ** Turn off power before wiring. Also, make sure to wire correctly. Improper wiring may cause electric fire or damage. -- Metal powder, oil, chemicals or hydrogen sulfide ** Do not use switching power supplies to charge rechargeable batteries. -- Inside freezers or refrigerators, near cooler exhaust, or other cold environments ** Make sure that the input voltage does not exceed the rating. Note polarity of input and output terminals and wire correctly. Incorrect wiring may cause blown fuses (AC input power), smoke or fire. -- Highly humid areas, such as a basement or conservatory PS5R Slim Line Power Supplies * Lightweight and compact in size * Wide power range: 10W-240W * Universal input: 10W to 90W: 85-264V AC/100-370V DC 120W and 240W: 85-264V AC/100-350V DC * Power Factor Correction for 60W to 240W (EN61000-3-2) * Meets SEMI F47 Sag Immunity (120W & 240W only) * Approved for Class 1, Div. 2 Hazardous Locations * Overcurrent protection, auto-reset * Overvoltage protection, shut down * Spring-up screw terminal type, IP20 * DIN rail or panel surface mount * Approvals: CE Marked TUV c-UL, UL508 UL1310 (PS5R-SB, -SC, -SD) UL/ANSI 12.12.01-2007 (Hazardous locations) EN50178:1997 LVD: EN60950:2000 EMC: Directive EN61204-3:2000 (EMI: Class B, EMS: Industrial) PS5R Slim Line models give you all the power of a traditional power supply in only half the space. The 10W and 15W are only 22.5mm wide, the 30W and 60W are 36mm wide, and the 90W is 46mm wide. The 120W unit has a width of only 50mm while the 240W is 80mm wide. They also come with all the convenient features you've come to expect from IDEC. Utilize them in tight spaces or save valuable DIN Rail space while still filling your requirements for power. With all the available choices, it's easy to find the one that's right for your application! IDEC Corporation * 1175 Elko Drive * Sunnyvale, CA 94089 * 800-262-IDEC (4332) * Fax: 408-745-5258 * www.IDEC.com/usa (c)2011 IDEC Corporation. All Rights Reserved. Catalog No. PS9Y-DS200-0 04/11 7.5K