5145 POWER ENTRY MODULES WITH LINE FILTER Standard- or Medical-Filter Inlet filter, front side mounting, circuit breaker TA45 2-pole C14 70 C Description Characteristics - Panel Mount: Screw-on from front side - 3 Functions: Inlet Protection class I, circuit breaker type TA45 2-pole, Line filter in standard and medical version - Quick connect terminals 6.3 x 0.8 mm - Alternative: version without line filter 6145 - We recommend for new applications type DF12 - All single elements are already wired Unwired versions available on request - Line switch non-illuminated or illuminated Thermal overload protection Optional with undervoltage release or remote trip release - Qualified for use in equipment according IEC/EN 60950 Approvals Weblinks Approvals: http://www.schurter.com/approvals RoHS: http://www.schurter.com/rohs - VDE License Number: 117118 - UL License Number: E72928 Technical Data Ratings IEC Ratings UL/CSA Leakage Current Dielectric Strength Allowable Operation Temp. Climatic Category Degree of Protection Protection Class Terminal Panel Thickness s Material: Housing 1 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 15 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -10 C to 55 C 10/055/21acc. to, IEC 60068-1 from front side IP 40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 Appliance-Inlet /-Outlet Circuit breaker Line Switch Line Filter MTBF 1 www.schurter.com C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I Acc. IEC/EN 60934, UL 1077, CSA 22.2 no. 235 2-pole rocker switch, illuminated or non-illuminated. Optional with undervoltage- or remote trip release Short circuit capacity Icn: at In < 3A/240VAC : 10 x In at In 3A/240VAC : 300A acc. to IEC 61058-1 Technical details Standard and Medical Version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details > 100'000 h acc. to MIL-HB-217 F 5145 POWER ENTRY MODULES WITH LINE FILTER Dimensions Length 67.5 mm Detail A 2 0 36 29 +0.2 1 43 6.3x0.8mm o6 3.25 A 0 6.3x0.8mm 50.7 M3/o 3.6 13.5 67.5* * --- Version TA45 with undervoltage release Technical Data of Filter-Components Rated Current Filter-Type [A] Inductances Capacitance Capacitance L [mH] CX [nF] CY [nF] 1 Standard Version 2 x 11 47 2.2 - 2 Standard Version 2x4 47 2.2 - 3 Standard Version 2 x 2.5 47 2.2 - 4 Standard Version 2 x 1.6 47 2.2 - 6 Standard Version 2 x 0.7 47 2.2 - 8 Standard Version 2 x 0.6 47 2.2 - 10 Standard Version 2 x 0.4 47 2.2 - 15 Standard Version 2 x 0.1 47 2.2 - 1 Medical Version (M5) 2 x 11 47 - 1 2 Medical Version (M5) 2x4 47 - 1 6 Medical Version (M5) 2 x 0.7 47 - 1 8 Medical Version (M5) 2 x 0.6 47 - 1 10 Medical Version (M5) 2 x 0.4 47 - 1 15 Medical Version (M5) 2 x 0.1 47 - 1 Diagrams Standard version Medical version 1) Line 2) Load 1) Line 2) Load 2 R [M ] www.schurter.com 80 0.1 72 +0.1 0 80 91.5 R 3-0.5 5145 POWER ENTRY MODULES WITH LINE FILTER Attenuation loss - - - - differential mode Standard version 1A 2A 3A 4A 6A 8A 10 A 15A 1A 2A 3A 4A 6A 8A 10 A 15A Medical version (M5) Packaging unit 20 Pcs Accessory Description Assorted Covers 3 www.schurter.com _____ common mode 5145 POWER ENTRY MODULES WITH LINE FILTER Table 1 Selection for type TA45 Order example W * Line switch * 2-pole, rocker actuated * Quick connect terminal Other types on request 5 3 P1 ABT a Diagram without Thermal overload protection Without illumination With illumination 220...240 V 110...120 V with 1-pole P2 P1 6 5 P2 with 2-pole P1 P2 P1 3 4 3 6 ABC ABT ABD A02 A04 A12 A14 A32 A34 } Colours Switch front W B 6 Rocker black black black white black - - - orange transp. Rocker legend printed OFF OFF L printed Illustration Colour of print O K Surface l O printed Colour of print black white P printed I O white black R printed I M printed O black white O l H F l embossed ON Illustration ON Surface Position of the rocker legend e.g F Rated current: * Without thermal overload protection: code C00 }I n = 20 A * With thermal overload protection: rated current In (A) In Code In Code In Code In Code 10,0 11,0 12,0 100 110 120 13,0 14,0 15,0 130 140 150 16,0 17,0 18,0 160 170 180 19,0 20,0 190 200 Without release: code C0 Undervoltage release P2 P1 P2 U< 4 Remote trip release b U< P1 P2 ba P1 P2 c P1 U< U E Z A Code Rated voltage Un * * * * 2 240 V AC * * * * 3 230 V AC * * * * 4 120 V AC www.schurter.com F 150 C0 5145 POWER ENTRY MODULES WITH LINE FILTER Technical data (continued) Circuit breaker Tripping characteristics In < 3 A Tripping characteristics In * 3...) 15 A [ min ] [ sec ] 10'000 [ min ] [ sec ] 10'000 Type TA45 Rated current In < 3 A 60 Type 1-pole protected 2000 30 20 1000 10 Ambient temp. TA45 I n 3... 15 A Rated current 60 2-pole protected 30 +23 C 20 1-pole protected 2'000 10 500 5 2-pole protected 1'000 +23 C Ambient temp. 500 5 200 200 100 1 100 1 50 20 20 10 10 5 5 2 2 1 1 0,5 0,5 Tripping time Tripping time 50 0,3 0,2 0,1 1,05 1,32 2 3 Multiple of rated current 4 5 8 10 0,3 0,2 0,1 1,05 1,32 [ x In ] 2 Multiple of rated current Effect of ambient temperature 1) The unit is calibrated for an ambient temperature of +23 C. To determine the rated current for a lower or higher ambient temperature, use a correction factor from the table below. * Ambient temperature [C] Correction factor -10 0,89 - 5 0,91 0 0,92 +23 1,00 +30 1,03 +40 1,08 +55 1,16 3 4 5 8 10 [ x In ] * Temperature must be measured at the rear of the breaker next to the terminals after equipment operating temperature has been reached. 1) Example Rated current at +23 C Ambient temperature Correction factor Chosen rated current at + 40 C ambient temperature 6,0 A +40 C 1,08 6 A x 1,08 = 6,5 A Order code (Order example) Type Order code TA45 (2-pole rocker-switch without accessories) 5145. A B T W F 1 5 0 C 0 see table 1 . 0 0 1 Wiring 0 Without 1 With Type of line filter 1 Standard 3 Medical Rated current of line filter 1 1 (A) 5 6 (A) 2 2 (A) 6 8 (A) 3 3 (A) 7 10 (A) 4 4 (A) 8 15 (A) Please note that Schurter will establish an internal part number for logistical use in additional to the order code. The format of this internal part number is, for example 5145.0031.001 5 www.schurter.com