Integra Series systems (2700, 2701, 2750) combine precision measurement, switching, and control in a single, tightly integrated enclosure for either rack-mounted or benchtop applications. These cost-effective, high performance test platforms offer affordable alternatives to separate DMMs and switch systems, dataloggers/ recorders, plug-in card data acquisition equipment, and VXI/PXI systems. The Integra Series plug-in switching and control modules offer unmatched flexibility and testing efficiency for a wide range of industries and applications. System builders can create test solutions with a combination of channel count, cost per c hannel, and system performance unmatched by any other single-box measurement system. The input modules provide the flexibility to vary the channel count from 20 to 200 (2-pole), apply a stimulus to the device under test, route signals, control system components, and make precision measurements with up to 14 functions. Robust digital I/O capabilities can be used for triggering, handshaking with other automation equipment, and alarm limit outputs. Scan rates of up to 500 channels/second (up to 3500 readings/second on a single channel) will increase test p roductivity. * Combines functions of DMM, switch system, and datalogger * True 61/2-digit (22-bit) resolution * Choice of 12 switch/control plug-in modules * Up to 200 differential input channels (with 300V isolation) for measurement and control * Convenient front panel inputs * Free LabVIEW(R), LabWindows/ CVI, Visual Basic, and C/C++ drivers (IVI style) Digital Multimeters & SYSTEMS Multimeter/Data Acquisition/ Switch Systems * Ethernet, GPIB, RS-232 communications capabilities * Free ExceLINX TM-1A datalogging software Fast Setup and Operation The Integra systems are fully integrated, off-the-shelf measurement and control systems. Their DMMlike interfaces make it easy for users to collect data and/or perform troubleshooting within minutes of installation and startup. Once sensor or DUT leads are hooked to the instrument's input, use the front panel controls to select the measurement function, range, filtering, scaling, trigger source, scanning sequence, alarms, and more. The free ExceLINX-1A software makes it easy to configure and use the system in a graphical "point-and-click" environment. This gives developers the basic tools needed to create a simple application without writing program code. The Advantage of Integrated Design The Integra systems offer a variety of advantages over existing solutions for ATE and data acquisition applications. For example, their flexible modular architecture and integrated measurement, switching, and control capabilities save rack space by reducing the number of separate instruments needed. This design also simplifies expanding the system as the number of channels grows or re-purposing it as new test requirements evolve. Integrated signal conditioning, scaling, stimulus, filtering and I/O capabilities eliminate the need for external circuitry when designing and building data acquisition systems. The Integra systems offer Built-in measurement functions accuracy and repeatability superior to plug-in include: data acquisition boards, while providing faster * DCV * ACV * DCI * ACI test times than typical DMM/switch systems. This * Resistance (2- or 4-wire, offset makes it possible to combine higher test yields compensation selectable) with higher test throughput. Ethernet The Model 2701 offers a 10/100 BaseT Ethernet connection for high speed and long distance communication between a computer and a virtually infinite number of instruments. Any PC with an Ethernet port can connect to a single Model 1.888.KEITHLEY (U.S. only) w w w.keithley.com A G R E A T E R M E A S U R E * Dry circuit ohms (20mV clamp) 2750 only * Temperature (with thermo couples, RTDs, or thermistors) * Frequency/Period * Continuity O F C O N F I D E N C E Integra Series integrated switching, measurement, and datalogging solutions Integra Series integrated switching, measurement, and datalogging solutions 2700, 2701, 2750 2700 2701 2750 DMM, Data Acquisition, Datalogging System w/2 Slots DMM, Data Acquisition, Datalogging System w/2 Slots and Ethernet Support DMM, Data Acquisition, Switching, Datalogging System w/5 Slots Accessories Supplied LabVIEW, LabWindows/ CVI, Visual Basic, and C/C++ drivers; manual; and Model 1751 Safety Test Leads. 2701 in a point-to-point configuration, to multiple Model 2701s through a hub, or to multiple Model 2701s distributed on a network. The Model 2701 Ethernet port uses the industry-standard TCP/IP socket interface. This provides data rates up 100Mbits/sec. and allows the instrument to be located up to 100 meters from the nearest computer or network hub in hardwired systems and miles in wireless Ethernet systems. The maximum distances between a control PC and the instruments are limited only by the size of the network. The instrument also provides a built-in diagnostic Web page for easy remote access to the Model 2701. Entering the instrument's IP address in the URL line of Microsoft Internet Explorer will allow communication with and control of the Model 2701. This Web page allows users to read and set network parameters, such as IP address, subnet mask, gateway, MAC address, and calibration dates, and to send commands to and query data from the Model 2701. Temperature Capabilities Integra Series mainframes support three major types of temperature sensors with built-in signal conditioning and 300V isolation: thermocouples, RTDs, and thermistors. To begin using a sensor, simply hook it up and the instrument does the rest. If a thermocouple is broken or disconnected, the instrument will alert the operator. The mainframes also support three methods for cold-junction compensation (CJC): automatic (built-in), external (built-in), and simulated. Accessories Available 2750-321A 7007-1 7007-2 7788 7789 7790 7797 7705-MTC-2 7707-MTC-2 KPCI-488LPA KUSB-488B Extra slot cover Shielded IEEE-488 Cable, 1m (3.3 ft.) (Models 2700, 2750 only) Shielded IEEE-488 Cable, 2m (6.6 ft.) (Models 2700, 2750 only) 50-Pin D-Shell Connector Kit (2 each)(for Models 7703, 7705 Modules w/D-sub Connectors) 50-Pin/25-Pin D-Shell Kit (1 each) 50-Pin Male, 50-Pin Female, and 25-Pin Male IDC D-Shell Connector Kit (1 each) (Ribbon Cable not Included) Calibration Extender Board (for Model 2750) 50-Pin Male to Female D-Sub Cable, 2m 25-Pin Male to Female D-Sub Cable, 2m IEEE-488 Interface/Controller for the PCI Bus (Models 2700, 2750 only) IEEE-488 USB-to-GPIB Interface Adapter (Models 2700, 2750 only) Services Available 2700-3Y-EW 1-year factory warranty extended to 3 years from date of shipment 2701-3Y-EW 1-year factory warranty extended to 3 years from date of shipment 2750-3Y-EW 1-year factory warranty extended to 3 years from date of shipment C/2700-3Y-ISO 3 (ISO-17025 accredited) calibrations within 3 years of purchase* C/2701-3Y-ISO 3 (ISO-17025 accredited) calibrations within 3 years of purchase* C/2750-3Y-ISO 3 (ISO-17025 accredited) calibrations within 3 years of purchase* *Not available in all countries Install up to five input modules in the 2750 mainframe (or up to two in the 2700 and 2701 mainframes). All switch/control modules are fully enclosed in impact-resistant plastic for exceptional ruggedness. Three connector alternatives simplify connecting the modules to DUTs. Rugged D-sub connectors allow quick, secure connections and are especially convenient when performing routine maintenance or when the system is installed in a rack. IDC ribbon cable adapters are supplied with the Model 7701, 7707, and 7709 modules for fast, uncomplicated hookups in production test and process monitoring applications. Oversize screw-terminal connectors simplify setup in applications that require the greatest connection flexibility. Additional D-sub and IDC ribbon cable connector kits and pre-wired cable assemblies are sold separately. Typical Applications * Production test of electronic products and devices * Accelerated stress testing (AST) * Process monitor and control * Device characterization/R&D * Low ohms, multichannel measurements 1.888.KEITHLEY (U.S. only) w w w.keithley.com A G R E A T E R M E A S U R E O F C O N F I D E N C E Integra Series integrated switching, measurement, and datalogging solutions Ordering Information Multimeter/Data Acquisition/ Switch Systems Digital Multimeters & SYSTEMS Integra Series integrated switching, measurement, and datalogging solutions 2700, 2701, 2750 Integra Series integrated switching, measurement, and datalogging solutions Digital Multimeters & SYSTEMS Immediate alarm notification independent of the PC provided by built-in open- collector digital I/O lines for control, external triggering, and HI/LO alarm/limit outputs. Fast and convenient 10/100BaseTX Ethernet with TCP/IP protocol (Model 2701). A variety of measurement and control modules makes it simple to mix, match, and change input signals or control lines as needed. Get up to 80 differential channels and scanning rates of up to 500 channels per second. Web-Enabled Data Acquisition and Control via Standard Ethernet A built-in 10/100BaseTXEthernet interface makes the Model 2701 the best choice for distributed data acquisition applications that demand stable, high precision measurements. Just connect it directly to an Ethernet port--there's no need for additional interface cards, proprietary cables, or software. The Model 2701 is a cost-effective solution for industrial monitoring and control applications. It combines remote communications with high measurement precision for research and development tasks, such as remote equipment diagnostics and economical monitoring of lab environments. Built-in relay cycle counters on each module for ease of maintenance. Free built-In Web diagnostic tool (2701 only) * Read and set network parameters * Send command strings and receive data * Debug To start communicating with the Integra Series instrument, simply connect the 2701 to a PC Ethernet port using the supplied RJ-45 crossover cable, start Microsoft(R) Internet Explorer version 5.0 or later, and type the instrument's IP address into the URL line. The built-in web diagnostic interface allows for easy communication and debugging, without the need to install external software. This interface makes it easy to read and set network parameters such as IP address, subnet mask, gateway, MAC address, calibration dates, and other data stored in the Integra Series instrument. It also takes readings from the instrument and allows the user to send command strings and receive data. 1.888.KEITHLEY (U.S. only) w w w.keithley.com A G R E A T E R M E A S U R E O F C O N F I D E N C E Integra Series integrated switching, measurement, and datalogging solutions Multimeter/Data Acquisition/ Switch Systems 2700, 2701, 2750 Ordering Information 7700 20-channel Differential Multiplexer Module with up to 50MHz Bandwidth, Automatic CJC, and Screw Terminals 7701 32-channel Differential Multiplexer Module with a 25- and 50-Pin Female D-Sub Connector. Supplied with Male IDCRibbon Cable Connectors 7702 40-channel Differential Multiplexer Module w/ Screw Terminals 7703 32-channel, High Speed, Differential Multiplexer Module with 2 50-Pin Female D-Sub Connectors. Includes 2 Mating Connectors 7705 40-channel, Single-pole Control Module with 2 50-Pin Female D-Sub Connectors. Includes 2 Mating Connectors 7706All-in-One I/O Module: 20-channel Differential Multiplexer w/Automatic CJC, 16 Digital Outputs, 2 Analog Outputs, a Counter/Totalizer, and Screw Terminals 7707 32-channel Digital I/O w/10-channel Differential Multiplexer Module with a 25-Pin Female and 50-Pin Male D-Sub Connectors. Supplied with Mating IDC Ribbon Cable Connectors 7708 40-channel Differential Multiplexer Module w/Automatic CJC and Screw Terminals 7709 6x8 Matrix Module with 25- and 50-Pin Female D-Sub Connectors. Supplied with Male IDC Ribbon Cable Connectors 7710 20-channel Solid-state/ Long Life Differential Multiplexer w/Automatic CJC and Screw Terminals Rugged 50-pin D-sub connectors ensure dependability and quick setup/teardown in production test racks. Screw terminals use oversize connectors for easier, mistake-free wiring. Easy-to-use removable terminals are available on some models. Software Solutions Whether the task calls for a simple start-up package to acquire several channels of data or the tools to create a fully custom acquisition and analysis solution, Keithley has the software needed to get the most performance from a Model 2700, 2701, or 2750 Multimeter/Switch System. Our broad range of software solutions makes it easy to get applications "Up & Running" quickly and economically. Measurement Ranges for the Integra Series Systems Measurement Ranges 1n 1 DC Voltage 100nV AC Voltage DC Current 100nV 1m 1 1k 1M 1000V 750V 10nA 3A 3A AC Current Frequency Period 1A Resistance (2-Wire) Resistance (4-Wire) 10 1 3Hz 2s 500kHz 333ms 120M 120M Logarithmic scale --500 0 --200C Temperature--RTD --200C Temperature--TC --80C Temperature--Thermistor Linear scale 500 1000 1500 1820C 150C Model 2750 only 7712 3.5GHz 50W RF Module with Dual 1x4 Configuration and SMAConnections A G R E A T E R 2000 630C 7711 2GHz 50W RF Module with Dual 1x4 Configuration and SMAConnections 1.888.KEITHLEY (U.S. only) w w w.keithley.com 1G Integra Series integrated switching, measurement, and datalogging solutions Multimeter/Data Acquisition/ Switch Systems M E A S U R E O F C O N F I D E N C E Digital Multimeters & SYSTEMS Integra Series integrated switching, measurement, and datalogging solutions 2700, 2701, 2750 Integra Series integrated switching, measurement, and datalogging solutions Digital Multimeters & SYSTEMS Important Features and Benefits * Relay counting--Provides preventive maintenance of the system and switches. * Full per-channel configurability--Each channel can be independently configured for making measurements. The parameters that can be chosen for each channel include speed, range, resolution, number of power line cycles (NPLC), filtering type, offset compensation, math functions to be displayed, CJC type, RTD type, frequency gate time, "m" and "b" values in mX + b format, HI/LO limits, low W (Model 2750 only), ratio calculation, and thermistor type. * Memory buffer--The mainframe's non-volatile wrap-around reading memory allows continuous, unattended datalogging over long periods. Data in the buffer can be transferred to a PC controller automatically as new data is acquired. The real-time clock can be used to time- and date-stamp readings for later review and interpretation. * 2 TTL-level digital inputs--Use to implement external triggers to initiate a scan sequence. * Channel monitor feature--Monitor any specific input channel on the front panel display during a scan. This feature can also serve as an analog trigger to initiate a scan sequence based on some external factor, such as a temperature rising above a pre-set limit. Only the data of interest is acquired, so there's no need to spend hours searching through reams of normal readings to find anomalous data. * 5 "per-channel" HI/LO alarm limit TTL outputs--Trigger external alarms or perform other control functions without a PC controller. * Dry circuit ohms (20mV clamp)--Protects sensitive devices from damage and prevents self-heating errors during testing (Model 2750 only). * Front/rear switch--Switching between the front and rear panel measurement inputs is as easy as pressing a button. Users can select the front panel inputs for tasks such as system setup and verification, manual probing, troubleshooting, and calibration, while the rear panel inputs through the modules allow fast, automated multiplexing and control. * Virtual channel--Stores the results of channel-to channel ratio and average math operations. * Onboard statistical analysis--Mathematical functions available at the push of a button are channel average, mX+b scaling, minimum, maximum, average, and standard deviation. * Battery-backed setup memory--Up to four different setup configurations can be stored in onboard memory. If the line power fails during a scan, the system will resume scanning where it stopped once power is restored. * GPIB and RS-232 interfaces (Models 2700 and 2750) * Ethernet and RS-232 interface (Model 2701 only) Which Integra Mainframe is the Best Choice for the Application? Use this selector guide to decide which Integra Series mainframe offers the combination of features and capacity that's right for a specific application. If testing requirements change in the future, switch/control modules and test code can be easily re-used. No. of differential input channels Matrix crosspoints Ohms resolution Dry circuit ohms (20mV clamp) No. of slots Memory buffer Size (2U height) Communications Scan-Rate (memory) Scan-Rate (bus) Max. Internal Trigger Rate Max. External Trigger Rate 2700 80 96 100 W No 2 55,000 rdgs Half-rack width GPIB, RS-232 180/s 145/s 2000/s 375/s 1.888.KEITHLEY (U.S. only) w w w.keithley.com 2701 80 96 100 W No 2 450,000 rdgs Half-rack width Ethernet, RS-232 500/s 440/s 2800/s 2000/s A 2750 200 240 1 W Yes 5 110,000 rdgs Full-rack width (19) GPIB, RS-232 230/s 210/s 2000/s 375/s G R E A T E R M E A S U R E O F C O N F I D E N C E Integra Series integrated switching, measurement, and datalogging solutions Multimeter/Data Acquisition/ Switch Systems 2700, 2701, 2750 Multimeter/Data Acquisition/ Switch Systems 2700, 2701, 2750 DC Characteristics1 Integra Series condensed specifications Voltage 11 Resistance 6, 8 Dry Circuit Resistance 21, 24 Continuity (2W) Current Range 100.0000 mV 1.000000 V 10.00000 V 100.0000 V 1000.000 V5 1.000000W24 10.00000W24 100.0000 W 1.000000kW 10.00000kW 100.0000kW 1.000000MW23 10.00000MW7, 23 100.0000MW7, 23 1.000000 W 10.00000 W 100.0000 W 1.000000kW 1.000kW 20.00000 mA 100.0000 mA 1.000000 A 3.000000 A Resolution 0.1 V 1.0 V 10 V 100 V 1 mV 1 W 10 W 100 W 1 mW 10 mW 100 mW 1.0 W 10 W 100 W 1 W 10 W 100 W 1 mW 100 mW 10 nA 100 nA 1.0 A 10 A Channel (Ratio) 10 Channel (Average) 10 Input Resistance or Open Circuit Voltage3 Accuracy: (ppm of reading + ppm of range) (ppm = parts per million) (e.g., 10ppm = 0.001%) 90 Day 24 Hour 4 2700/2701 2750 23C 1 23C 5 15 + 30 25 + 35 >10 GW >10 GW 15 + 6 25 + 7 >10 GW >10 GW 10 + 4 20 + 5 >10 GW >10 GW 15 + 6 35 + 9 10 MW 1% 10 MW 1% 20 + 6 35 + 9 10 MW 1% 10 MW 1% 10 mA 5.9 V 80 + 40 80 + 40 10 mA 5.9 V 20 + 20 80 + 20 1 mA 6.9 V 12.2 V 20 + 20 80 + 20 1 mA 6.9 V 12.2 V 20 + 6 80 + 6 100 A 6.9 V 6.8 V 20 + 6 80 + 6 10 A 12.8 V 12.8 V 20 + 6 80 + 10 10 A 12.8 V 12.8 V 20 + 6 80 + 10 7.0 V 7.0 V 150 + 6 200 + 10 0.7 A//10 MW 7.0 V 7.0 V 800 + 30 2000 + 30 0.7 A//10 MW 10 mA 20 mV 80 + 40 80 + 40 1 mA 20 mV 25 + 40 80 + 40 100 A 20 mV 25 + 40 90 + 40 10 A 20 mV 25 + 90 180 + 90 1 mA 6.9 V 12.2 V 40 + 100 100 + 100 < 0.2 V 60 + 30 300 + 80 < 0.1 V 100 + 300 300 + 800 200 + 30 500 + 80 < 0.5 V 9 9 1000 + 15 1200 + 40 < 1.5 V Ratio Accuracy = Accuracy of selected Channel Range + Accuracy of Paired Channel Range Average Accuracy = Accuracy of selected Channel Range + Accuracy of Paired Channel Range Temperature 19 1 Year 23C 5 30 + 35 30 + 7 30 + 5 45 + 9 50 + 9 100 + 40 100 + 20 100 + 20 100 + 6 100 + 6 100 + 10 100 + 10 400 + 10 2000 + 30 100 + 40 100 + 40 140 + 40 400 + 90 100 + 100 500 + 80 500 + 800 800 + 80 1200 + 40 Temperature Coefficient 0-18C & 28-50C (1 + 5)/C (1 + 1)/C (1 + 1)/C (5 + 1)/C (5 + 1)/C (8 + 1)/C (8 + 1)/C (8 + 1)/C (8 + 1)/C (8 + 1)/C (8 + 1)/C (8 + 1)/C (70 + 1)/C (385 + 1)/C (8 + 1)/C (8 + 1)/C (8 + 1)/C (8 + 1)/C (8 + 1)/C (50 + 5)/C (50 + 50)/C (50 + 5)/C (50 + 5)/C DC MEASUREMENT SPEEDS15 (Displayed in C, F, or K. Exclusive of probe errors.) Single Channel, 60Hz (50Hz) Operation Thermocouples (Accuracy based on ITS-90) Function 90 Day/1 Year (23C 5C) Relative to Using Simulated 77XX Type Range Resolution Reference Junction Module* J -200 to + 760C 0.001 C 0.2C 1.0C K -200 to +1372C 0.001 C 0.2C 1.0C N -200 to +1300C 0.001 C 0.2C 1.0C T -200 to + 400C 0.001 C 0.2C 1.0C E -200 to +1000C 0.001 C 0.2C 1.0C R 0 to +1768C 0.1 C 0.6C 1.8C S 0 to +1768C 0.1 C 0.6C 1.8C B +350 to +1820C 0.1 C 0.6C 1.8C * Using 7710 Module: J: 2.5C; K: 1C. N, T, E Types: 1.5C. R, S, B Types: 2.7C. Temperature Coefficient 0-18C & 28-50C 0.03C/C 0.03C/C 0.03C/C 0.03C/C 0.03C/C 0.03C/C 0.03C/C 0.03C/C (100W platinum [PT100], D100, F100, PT385, PT3916, or user type. Offset compensation On.) 0.01C 2700 and 2750 only 2701 only 4WW (<10M) 4WW OComp, RTD 22 0.06C 0.003C/C Multiple Channels, Into Memory 18 0.08C 0.002C/C 7710 Scanning DCV 7710 Scanning DCV with Limits or Time Stamp On 7710 Scanning DCV alternating 2WW Thermistor: (2.2kW, 5kW, and 10kW)20 -80 to +150C DCV, DCI, W (<10M), Thermocouple, Thermistor Channel (Ratio), Channel (AVG) 4-Wire RTD: -200 to +630C Digits 6.5 12,16 6.516 6.5 12,16 5.5 12,16 5.5 16, 17 5.5 17 4.5 17 3.5 6.516 6.516 5.5 17 6.516 6.516 5.5 16, 17 6.516 6.516 5.5 17 0.01C DC SYSTEM SPEEDS15,18 Range Changes (excludes 4WW)16: Function Changes16: Autorange Time16: ASCII readings to RS-232 (19.2k baud): Max. external trigger rate: 1.888.KEITHLEY (U.S. only) w w w.keithley.com 2700/2750 50/s (42/s) 50/s (42/s) <30 ms 55/s 375/s 2701 50/s (42/s) 50/s (42/s) <30 ms 300/s 2000/s A Readings/s 5 (4) 35 (28) 45 (36) 150 (120) 300 (240) 500 (400) 2500 (2000) 3500 (2800) 1.4 (1.1) 15 (12) 33 (25) 0.9 (0.7) 8 (6.4) 18 (14.4) 2.5 (2) 15 (12) 25 (20) Multiple Channels, Into and Out of Memory to GPIB 16, 18 or Ethernet 7702 Scanning DCV 7700 and 7708 Scanning Temperature (T/C) 7710 Scanning DCV 7710 Scanning DCV with Limits or Time Stamp On 7710 Scanning DCV alternating 2WW G R E A T E R M E A S U R E O F C O N F I D E N C E PLCs 10 1 1 0.1 0.1 0.1 0.01 0.002 10 1 0.1 10 1 0.1 10 1 0.1 Channels/s 2700 2701 2750 180/s 500/s 230/s 170/s 500/s 230/s 45/s 115/s 60/s Channels/s 2700 2701 2750 65/s 75/s 65/s 50/s 50/s 50/s 145/s 440/s 210/s 145/s 440/s 210/s 40/s 115/s 55/s Digital Multimeters & SYSTEMS Function Test Current 5% or Burden Voltage Integra Series condensed specifications Conditions: MED (1 PLC) 2 or 10 PLC or MED (1 PLC) with Digital Filter of 10 Multimeter/Data Acquisition/ Switch Systems 2700, 2701, 2750 DC SPEED vs. NOISE REJECTION Readings/s12 0.1 (0.08) 15 (12) 500 (400) 2500 (2000) 3500 (2800) DC MEASUREMENT CHARACTERISTICS DC Volts A-D Linearity: 2.0 ppm of reading + 1.0 ppm of range. Input Impedance: 100mV-10V Ranges: Selectable >10GW // with <400pF or 10MW 1%. 100V, 1000V Ranges: 10MW 1%. Dry Circuit: 100kW 1% // <1F. Earth Isolation: 500V peak, >10GW and <300pF any terminal to chassis. Input Bias Current: <75pA at 23C. Common Mode Current: <500nApp at 50Hz or 60Hz. Autozero Error: Add (2ppm of range error + 5V) for <10 minutes and 1C. Input Protection: 1000V, all ranges. 300V with plug in modules. Resistance MaxIMUM 4WW Lead Resistance: 80% of range per lead (Dry Ckt mode). 5W per lead for 1W range; 10% of range per lead for 10W, 100W, and 1kW ranges; 1kW per lead for all other ranges. Offset Compensation: Selectable on 4WW, 1W, 10W, 100W, 1kW, and 10kW ranges. Continuity Threshold: Adjustable 1 to 1000W. Input Protection: 1000V, all Source Inputs, 350V Sense Inputs. 300V with plug-in modules. DC Current Shunt Resistors: 100mA-3A, 0.1W. 20mA, 5W. Input Protection: 3A, 250V fuse. DC Notes 1. 2. 20% overrange except on 1000V and 3A. Add the following to "ppm of range" uncertainty; 100mV 15ppm; 1V and 100V 2ppm; for Model 2750 1W and Dry Circuit W 40ppm; 101MW 2ppm, for Models 2700/2701 100W 30ppm, 20mA and 1A 10ppm, 100mA 40ppm. 3. 2% (measured with 10MW input resistance DMM, >10GW DMM on 10MW and 100MW ranges). For Dry Circuit W, 25% with Input HI connected to Sense HI; with Sense HI disconnected add 30mV. 4. Relative to calibration accuracy. 5. For signal levels >500V, add 0.02ppm/V uncertainty for portion exceeding 500V. 6. Specifications are for 4-wire W, 1W, 10W, and 100W with offset compensation on. With 77XX plug-in modules, LSYNC on. With offset compensation on, OPEN CKT. VOLTAGE is 12.8V. For 2-wire W add 1.5W to "ppm of range" uncertainty. 1W range is 4-wire only. 7. Must have 10% matching of lead resistance in Input HI and LO. 8. Add the following to "ppm of reading" uncertainty when using plug in modules: 10 kW 100 kW 1 MW 10 MW 100 MW All Modules: 220 ppm 2200 ppm 7701, 7703, 7707, 7709 Modules: 10 ppm 100 ppm 1000 ppm 1% 10% 7706, 7708, 7710 Modules: 5 ppm 50 ppm 500 ppm 5000 ppm 5% 7710 Module 23C 5C: 11 ppm 110 ppm 1100 ppm 1.1% 11% 9. 10. 11. 12. 13. 14. 15. Add 1.5V when used with plug in modules. For RATIO, DCV only. For AVERAGE, DCV, and Thermocouples only. Available with plug in modules only. Add 6V to "of range" uncertainty when using Models 7701, 7703, and 7707, and 3V for Models 7706 and 7709. Auto zero off. For LSYNC On, line frequency 0.1 %. For LSYNC Off, use 60dB for 1PLC. For 1kW unbalance in LO lead. AC CMRR is 70dB. Speeds are for 60Hz (50Hz) operation using factory defaults operating conditions (*RST). Autorange off, Display off, Limits off, Trigger delay = 0. 16. Speeds include measurements and binary data transfer out the GPIB or ASCII data transfer for Ethernet and RS-232 (reading element only). 17. Sample count = 1000, auto zero off (into memory buffer). 18. Auto zero off, NPLC = 0.01 (Models 2700 and 2750), NPLC = 0.002 (Model 2701). 19. Additional Uncertainty: Plug-In Modules Front Terminals 7709 7701, 7703, 7707 7700, 7708, 7706 Simulated Simulated Simulated 7710 Using Using TypeRangeRef. JunctionRef. JunctionRef. Junction CJC CJC J -200 to 0C 0.1 0.1 0.3 0.8 1.6 K -200 to 0C 0.2 0.2 0.4 0.8 1.6 N -200 to 0C 0.3 0.3 0.6 0.8 1.6 T -200 to 0C 0.2 0.1 0.4 0.8 1.6 E -200 to 0C - 0.1 0.3 0.8 1.6 R 0 to +400C 0.4 0.6 1.2 0.5 1.0 S 0 to +400C 0.4 0.6 1.2 0.5 1.0 B +350 to +1100C 0.8 0.3 1.7 0.5 1.0 20. For lead resistance >0W, add the following uncertainty/W for measurement temperatures of: Thermocouples Conversion: ITS-90. Reference Junction: Internal, External, or Simulated (Fixed). Open Circuit Check: Selectable per channel. Open >11.4kW 200W. 21. 22. 23. 24. 70-100C 100-150C 0.22C 1.11C 2.2 kW (44004) 0.10C 0.46C 5.0 kW (44007) 0.04C 0.19C 10 kW (44006) For 4-wire W only, offset compensation on, LSYNC on. For Dry Circuit 1kW range, 2 readings/s max. For 2750 Front Inputs, add the following to Temperature Coefficient "ppm of reading" uncertainty: 1MW 25ppm, 10MW 250ppm, 100MW 2500ppm. Operating environment specified for 0C to 50C and 50% RH at 35C. Model 2750 only. 25. Front panel resolution is limited to 0.1W. AC SPECIFICATIONS Digital Multimeters & SYSTEMS 1 Accuracy: (% of reading + % of range), 23C 5C Function Voltage 2 Current 2 Range 100.0000 mV 1.000000 V 10.00000 V 100.0000 V 750.000 V 1.000000 A 3.00000 A 14 Resolution 0.1 V 1.0 V 10 V 100 V 1.0 V 1.0 A 10 A Calibration Cycle 3 Hz-10 Hz 10 Hz-20 kHz 20 kHz-50 kHz 50 kHz-100 kHz 100 kHz-300 kHz 90 Days (all ranges) 0.35 + 0.03 0.05 + 0.03 0.11 + 0.05 0.6 + 0.08 4.0 + 0.5 1 Year (all ranges) 0.35 + 0.03 0.06 + 0.03 0.12 + 0.05 0.6 + 0.08 4.0 + 0.5 0.01 + 0.006 0.03 + 0.01 (Temp. Coeff.)/C3 0.035 + 0.003 0.005 + 0.003 0.006 + 0.005 90 Day/1 Year 3 Hz-10 Hz 0.30 + 0.04 0.35 + 0.06 0.035 + 0.006 10 Hz-3 kHz 0.10 + 0.04 0.16 + 0.06 0.015 + 0.006 3 kHz-5 kHz 0.14 + 0.04 0.18 + 0.06 (Temp. Coeff.)/C3 Frequency 4 and Period 100 mV to 750 V 0.333 ppm 3.33 ppm 33.3 ppm 1.888.KEITHLEY (U.S. only) w w w.keithley.com 90 Day/1 Year (3 Hz-500 kHz) (333 ms-2 s) 100 ppm + 0.333 ppm (SLOW, 1s gate) 100 ppm + 3.33 ppm (MED, 100ms gate) 100 ppm + 33.3 ppm (FAST, 10ms gate) A G R E A T E R M E A S U R E O F C O N F I D E N C E Integra Series condensed specifications Integra Series condensed specifications Rate Filter 10 50 1 Off 0.1 Off 0.01 Off 0.002 Off RMS Noise 10V Range Digits 2700,2750 2701 NMRR CMRR14 6.5 <1.2 V <2.5 V 110 dB13 140 dB 6.5 <4 V <6 V 90 dB13 140 dB 5.5 <22 V <40 V -- 80 dB 4.5 <150 V <300 V -- 80 dB 3.5 -- <1 mV -- 60 dB Multimeter/Data Acquisition/ Switch Systems Integra Series condensed specifications Low Frequency Uncertainty 20 Hz - 30 Hz 30 Hz - 50 Hz 50 Hz - 100 Hz 100 Hz - 200 Hz 200 Hz - 300 Hz >300 Hz Med 0.3 0 0 0 0 0 1-2 2-3 Crest Factor: 5 Additional Uncertainty: 0.05 0.15 Max. Fundamental Freq.: 50kHz 50kHz Maximum Crest Factor: 5 at full-scale. 3-4 0.30 3kHz Fast -- -- 1.0 0.18 0.10 0 4-5 0.40 1kHz AC MEASUREMENT CHARACTERISTICS AC Volts Measurement Method: AC-coupled, True RMS. Input Impedance: 1MW 2% // by <100pF. Input Protection: 1000Vp or 400VDC. 300Vrms with plug in modules. AC Current Measurement Method: AC-coupled, True RMS. Shunt Resistance: 0.1W. Burden Voltage: 1A <0.5Vrms, 3A <1.5Vrms. Add 1.5Vrms when used with plug in modules. Input Protection: 3A, 250V fuse. Frequency and Period Measurement Method: Reciprocal counting technique. Gate Time: SLOW 1s, MED 100ms, and FAST 10ms. AC General AC CMRR6: 70dB. Volt Hertz Product: 8 x 107. AC Measurement Speeds 7, 13 Single Channel, 60Hz (50Hz) Operation Function ACV, ACI Frequency, Period Digits 6.5 6.5 6.5 9 6.5 5.5 4.5 4.5 10 Readings/s 2s/Reading 4.8 (4) 40 (32) 1 (1) 9 (9) 35 (35) 65 (65) Rate SLOW MED FAST SLOW MED FAST FAST Bandwidth 3 Hz-300 kHz 30 Hz-300 kHz 300 Hz-300 kHz 3 Hz-300 kHz 30 Hz-300 kHz 300 Hz-300 kHz 300 Hz-300 kHz Multiple Channel 7710 Scanning ACV 10, 11: 500/s. 7710 Scanning ACV with Auto delay On : 2s/reading. AC System Speeds 7, 9, 11 AC System Speed: Range Changes:12 Function Changes:12 Autorange Time: ASCII Readings to RS-232 (19.2k baud): Max. External Trigger Rate: 2700/2750 (19.2K) 4/s (3/s) 4/s (3/s) < 3s 50/s 250/s 1.888.KEITHLEY (U.S. only) w w w.keithley.com 2701 (115.2K) 4/s (3/s) 4/s (3/s) < 3s 300/s 2000/s AC Notes 1. 20% overrange except on 750V and 3A. 2. Specification are for SLOW mode and sine wave inputs >5% of range. SLOW and MED are multi-sample A/D conversions. FAST is DETector:BANDwidth 300 with nPLC = 1.0. 3. Applies to 0-18C and 28-50C. 4. For square wave inputs >10% of ACV range, except 100mV range. 100mV range frequency must be >10Hz if input is <20mV. 5. Applies to non-sine waves >5Hz. 6. For 1kW unbalance in LO lead. 7. Speeds are for 60Hz (50Hz) operation using factory defaults operating conditions (*RST). Autorange off, Display off, Limits off, Trigger delay=0.. 8. For ACV inputs at frequencies of 50 or 60Hz (10%), add the following to "% of Range" uncertainty: 100mV 0.25%, 1V 0.05%, 10V 0.13%, 100V 0.03%, 750V 0.015 (Model 2701 only). 9. Auto Zero off. 10. Sample count = 1024. 11. DETector:BANDwidth 300 with nPLC = 0.006 (2701 only). 12. Maximum useful limit with trigger delay = 175ms. 13. Includes measurement and binary data transfer out GPIB or ASCII data transfer for Ethernet and RS-232 (Reading Element only). General Expansion Slots: 2 (2700, 2701), 5 (2750). Power Supply: 100V / 120V / 220V / 240V 10%. Line Frequency: 45Hz to 66Hz and 360Hz to 440Hz, automatically sensed at power-up. Power Consumption: 28VA (2700), 80VA (2701, 2750). Operating Environment: Specified for 0C to 50C. Specified to 80% RH at 35C. Storage Environment: -40C to 70C. Battery: Lithium battery-backed memory, 3 years @ 23C (Models 2700, 2750) Lithium Ion batterybacked memory, 30 days of buffer storage @ 23C and >4 hours charge time. Battery lifetime: >3 years @ 23C, >1.5 years @ 50C (Model 2701) EMC: Conforms to European Union Directive 89/336/EEC EN61326-1. Safety: Conforms to European Union Directive 73/23/EEC EN61010-1, CAT I. Vibration: MIL-PRF-28800F Class 3, Random. Warm-up: 2 hours to rated accuracy. Dimensions: Rack Mounting: 89mm high x 213mm wide (2700, 2701) or 485mm wide (2750) x 370mm deep (3.5 in x 8.375 in or 19 in x 14.563 in). Bench Configuration (with handle and feet): 104mm high x 238mm wide (2700, 2701) or 485mm wide (2750) x 370mm deep (4.125 in x 9.375 in (2700, 2701) or 19 in (2750) x 14.563 in). Shipping Weight: 6.5kg (14 lbs.) (2700, 2701) or 13kg (28 lbs.) (2750). DIGITAL I/O: 2 inputs, 1 for triggering and 1 for hardware interlock. 5 outputs, 4 for Reading Limits and 1 for Master Limit. Outputs are TTL compatible or can sink 250mA, diode clamped to 40V. Triggering and Memory: Window Filter Sensitivity: 0.01%, 0.1%, 1%, 10%, or Full-scale of range (none). Reading Hold Sensitivity: 0.01%, 0.1%, 1%, or 10% of reading. Trigger Delay: 0 to 99 hrs (1ms step size). External Trigger Delay: <2ms (2700), <1ms (2701, 2750). External Trigger Jitter: <1ms (2700), <500s (2701), <500s (2750). Memory Size: 55,000 readings (2700), 450,000 readings (2701), 110,000 readings (2750). Math Functions: Rel, Min/Max/Average/Std Dev/Peak-to-Peak (of stored reading), Limit Test, %, 1/x, and mX+b with user defined units displayed. Remote Interface: GPIB (IEEE-488.2) (2700, 2750), RS-232C (2700, 2701, and 2750). Ethernet TCP/IP (10bT and 100bT) (2701) SCPI (Standard Commands for Programmable Instruments) LabVIEW Drivers For Model 2701: Ethernet: RJ-45 connector, TCP/IP, 10bT and 100bTx autosensed. IP Configuration: Static or DHCP. Password Protection: 11 Characters. Software: Windows 98, NT, 2000, ME, and XP compatible. Internet Explorer 5.0 or higher required. Web page server by 2701. A G R E A T E R M E A S U R E O F C O N F I D E N C E Integra Series condensed specifications Additional Uncertainty (% of reading) Digital Multimeters & SYSTEMS 2700, 2701, 2750 2700, 2701, 2750 Multimeter/Data Acquisition/ Switch Systems Digital Multimeters & SYSTEMS Module Capabilities Overview 7700 7701 7702 7703 7705 7706 7707 7708 7709 7710 DC Volts DC Current Temperature T/C w/Automatic CJC T/C w/External CJC RTD Thermistor Resistance (2- or 4-wire) Continuity AC Volts AC Current Frequency Event Counter/Totalizer Signal Routing/Control Digital Input Digital Output Analog Output RF Switching Integra Plug-In Modules 1.888.KEITHLEY (U.S. only) w w w.keithley.com A G R E A T E R M E A S U R E O F C O N F I D E N C E 7711 7712 Integra Series switch/control modules Integra Series switch/control modules Switch/Control Module Capabilities All plug-in modules are compatible with the two-slot Model 2700 and Model 2701 Multimeter/Data Acquisition Systems and the five-slot Model 2750 Multimeter/Switch System. When the application's needs change, simply change modules. Integra systems reconfigure themselves automatically.