Like our popular C200H/HS mid-size PLC series, Omron’s new C200Hα
series offers the advantages of large PLC performance and I/O versatility
in a mid-size PLC package and price range. But there’s more to the
new C200Hα series—a lot more.
Improvements to the existing series, such as greater memory capacity
and faster processing speed, strengthen the C200Hα series’ capabilities
as a controller. Newly added features, such as a protocol macro and
an optional PCMCIA Card Module, transform the C200Hα series
into a powerful on-site data processing system—and transforms
your workplace into a highly responsive, information-based operation.
MORE POWER. MORE FLEXIBILITY. MORE SPEED.
More I/O Points
C200HS 880
C200Hα1,184 maximum
More Special I/O Modules
C200HS 10
C200Hα16
Increased Processing Speed
C200HS 0.375 µs LD execution
C200Hα0.1µs LD execution speed
Increased Memory Capacity
C200HS 15.2k words
C200Hα31.2k words maximum
Increased Data Memory
C200HS 6K words
C200Hα24K words maximum
Enlarged SYSMAC LINK Data Link Area
C200HS 918 words
C200Hα2,966 words
Increased Local Expansion
C200HS 2 expansion backplanes max.
C200Hα3 expansion backplanes max.
WHY OMRON?
Quality Recognized Industry-Wide
Omron performs 100% quality inspection and testing procedures
at every stage of manufacturing – your assurance of satisfaction.
Your 24-Hour Automation Solution
Get Omron’s SmartFactor y advantage by utilizing our application
engineering know-how, extensive training, and 24-hour technical
support from anywhere in the USA. Through our commitment to
flexible manufacturing, Omr on has become a leader in the manufacture
of Sensors, Digital Panel Meters, Digital Displays, Counters, Timers,
PLCs, Process and Temperature Controllers, and other control
devices.
Technical Information FAST
Obtain up-to-date technical specifications for all Omron products
24 hours a day, 7 days a week from your fax machine. Call our
ControlFax at 847.843.1963. Request #50 for a directory of
all documents available.
Information is also available on the internet. Visit our web site at
http://oei.omron.com and get the latest information on Omron
products and literature.
Worldwide Sales and Support Network
You’ll find over 200 stocking distributors and local sales offices
across the United States. With distributors in Canada and Mexico,
and branch offices worldwide, Omron provides replacement
components, service and multilingual documentation virtually
anywhere in the world.
Expertise You Can Rely On
You can rely on the high quality PLC products you’ve come to
expect from Omron. Trust our nationwide network of local stocking
distributors and system integrators to offer expertise you can
depend on. Just give us a call.
INTRODUCTION
TABLE OF CONTENTS
SECTION PAGE NUMBER
SYSTEM COMPONENTS 1
System Overview
Introduction 2
Overview 6
PLC System specifications 8
CPU
Features 9
Selection Guide 10
Specifications and Characteristics 11
Communication Boards 14
Protocol Macro Function 15
Memory Cassettes 17
Power Supply Modules 18
Backplanes 19
Connecting I/O Cables 21
Discrete I/O Modules 22
Special I/O Modules 26
COMMUNICATIONS 69
Overview 70
Communication Modules 72
Fiber-optic Cable and Connections 89
PROGRAMMING 91
Programming Software
SSS and SYSWIN 92
Protocol Support Software 94
Programming Peripherals and Cables 97
Programming Instructions 99
STANDARD PARTS 123
COMPLEMENTARY 141
PRODUCTS
Operator Interface Terminals 142
PART NUMBER INDEX 149
NOTE: Specifications to chang e without notice.
Warranty: Omron certifies all of its products either meet
or exceed stipulated specifications. Omron is not liable
for stenographic and/or clerical errors.
Omron's obligation under this warranty is limited solely
to repair or replacement at Omron's discretion. Omron
will not be liable for any design furnished by Buyer and
incorporated into equipment.
This warranty is voided if the product is altered in any
wa y or suffers consequential damage due to negligence
or misuse.
Omron is not to suffer risk due to the suitability or
unsuitability or the results of the use of its products used
in combination with any electrical or electronic
components, circuits , systems assemblies or any other
materials or substances or environments.
The f oregoing warning is the only warranty which Omron
Electronics, Inc., provides with respect to the products
listed herein. No other warranties, expressed, implied,
or statutor y shall apply, whether as to merchantability,
fitness f or a particular purpose, description, or otherwise.
Limitation of Liability: Notwithstanding any other
statement herein, Omron Electronics, Inc., its contractors
and suppliers, shall not be liab le f or any special, indirect,
incidental or consequential damages. The remedies of
the purchaser set for th herein are exclusive where so
stated and the total cumulative liability of Omron
Electronics, Inc., its contractors and suppliers, with
respect to this contract or anything done in connection
therewith, shall not exceed replacement price
reimbursement as to the product on which such liability
is based.
SYSTEM COMPONENTS
SYSTEM COMPONENTS 1
System Overview
Introduction 2
Overview 6
PLC System specifications 8
CPU
Features 9
Selection Guide 10
Specifications and Characteristics 11
Communication Boards 14
Protocol Macro Function 15
Memory Cassettes 17
Power Supply Modules 18
Backplanes 19
Connecting I/O Cables 21
Discrete I/O Modules 22
Special I/O Modules 26
1
The New C200Hα Series:
Powerful Mid-Sized Machine Control, Powerful Onsite Data Processing
Improved Special
I/O Modules
The maximum number of Special I/O
Modules that can be mounted on the CPU
has been increased from 10 to 16 modules.
You can easily manage a control system
with the right combination of Special I/O
Modules.
The intelligent I/O read and intelligent I/O
write instructions can be executed to
transfer more than one word of data. All
of the C200HS Special I/O Modules can
be used without any modification. In
addition, a PC Card Module, Motion
Control Module, and Two-axis High-speed
Counter Module have been added.
SYSTEM COMPONENTS
Migrate Easily
While the functions and capabilities of the
C200Hα series have been dramatically
enhanced, common languages and I/O
units allow smooth migration from
C200H/HS PLCs.
Interface to Memory
or Ethernet via PC
Card Module
The PC Card Module provides two
PCMCIA interface slots. Either two type I
or II or one type III PC card can be installed.
The system accepts SRAM, FLASH and
ATA cards.
PC File Operations: C200HX/HG/HE
memory contents may be written to
memory cards as files using ladder-
diagram instructions. File contents can be
compared and searched and word data
can be separated by commas in the file
format so that commercially available
spreadsheets may be used.
Ethernet Connection: Using an Ethernet
PCMCIA card, data may be exchanged
using Omron’s FINS protocol via UDP/IP.
A Built-in Protocol
Macro Function
Previously, it was necessary to write a
communications program for the ASCII
Module or BASIC Module whenever a
measurement device or component was
connected to the PLC. The C200H Alpha
PLCs are equipped with the Protocol
Macro Function which incorporates these
communications progr ams into the ladder
program with just a f e w ladder instructions.
A variety of workplace data can be
processed in real-time improving quality
and reducing total product cost. System
development time can be reduced
substantially.
2
SYSTEM COMPONENTS
Connect to a V ariety
of Serial Devices
The C200Hα CPU's can be equipped with
one of six communication boards. By
installing the appropriate communication
board, the CPU can communicate with
SYSMA C Link / SYSMAC Net modules, a
PC Card module or serial devices. Using
the Protocol Macro Function built into the
C200HW-COM04-E, C200HW-COM05-E
or C200HW-COM06-E communications
boards, communications sequences for
one of seven types of installed Omron
protocols may be used or customized for
a modem, operator interface, bar code
reader , temper ature controller, or any kind
of RS-232C, RS-422 or RS-485 device.
Open up Your
Communications
Possibilities in All
Three Automation
Network Levels
DEVICE LEVEL NETWORKS: The new
C200HW-DRM21 Module supports
DeviceNet open multi-vendor network
communications. DeviceNet makes it
possible to connect devices that have a
wide variety of parameters or data, such
as inverters or analog devices. It also
allows other DeviceNet products to be
connected as well.
CONTROL LEVEL NETW ORKS: Omron's
SYSMA C Link and SYSMAC Net networks
provide high-speed real-time data transf er.
SYSMAC Link’s data link capacity has
been increased from 918 words to 2,966
words.
INFORMATION LEVEL NETW ORKS: The
C200HW -PCS01 PCMCIA Module allo ws
data exchange with CV Ethernet units,
PCs and workstations using Omron’ s FINS
protocol via Ethernet UDP/IP.
Build Networks
Easily with the
Alpha’s Built-in
Features.
Using built-in Host Link function of the
C200H Apha, connect directly to operator
interface terminals using a cable as an
interface, or use a One-to One data links
between alpha PLCs are just as easy to
make.
When networking with a PC, the TXD and
RXD instructions can be used to carry out
RS-232C communications from the PLC,
and the STUP instruction can be used to
switch between Host Link and RS-232C,
communications.
3
SYSTEM COMPONENTS
CPU RACK
EXPANSION I/O RACK
SLAVE RACKS
BUILD YOUR
OWN CONTROL
AND DATA
PROCESSING
SYSTEM
CPU
Choose from 11 CPU models
Separate CPU and pow er supply
CPU and Expansion
Backplanes
CPU and power supply mount on
a dedicated CPU backplanes
Local expansion may be done
with the new space-saving
C200Hα expansion backplanes
or current C200H backplanes
Connect up to 5 remote I/O
backplanes
Special I/O
Take full advantage of the
C200Hαs power with any
combination of 20 Special I/O
Modules
Communications
All CPUs include a multifunctional
peripheral port to communicate
to programming peripherals
Standard Host Link port is built
into selected CPUs
One of six communications
boards can also be installed in
the CPU. When used with the
protocol macro function, these
boards provide a simple way to
connect with a SYSMAC Link or
SYSMAC Net Link module, to
communicate with a Modem,
operator interface, bar code
reader , Process Controller or an y
kind of RS-232C , RS-422 or RS-
485 device.
Software Support
Supported by both SYSMAC
Support Software Version 1.2 or
greater and SYSWIN v ersion 3.0
or greater
EEPROM MEMORY CASSETTES
4K words C200HW-ME04K
8K words C200HW-ME08K
16K words C200HW-ME16K
32K words C200HW-ME32K
EPROM MEMORY CASSETTES
16/32K words C200HS-MP16K
p.17 p.9
POWER SUPPLY
MODULE
C200HW-PA204
C200HW-PA204S
C200HW-PD024
p.18
CPU BACKPLANE
C200HW-BC031 C200HW-BC051
C200HW-BC081 C200HW-BC101
p.19
POWER SUPPLY
MODULE
C200HW-PA204
C200HW-PA204S
C200HW-PD024
p.18
I/O CONNECTING
CABLE
C200H-CN❏❏1
(30cm,70cm,2m,5m,10m)
p.21
EXPANSION 1/O BACKPLANE
C200HW-BI031
C200HW-BI051
C200HW-BI081
C200HW-BI101
p.19
SLAVE I/O BACKPLANE
C200H-BC031-V2
C200H-BC051-V2
C200H-BC081-V2
C200H-BC101-V2
p.20
REMOTE I/O SLAVE MODULE
Fiber-optic, 100/200 VAC C200H-RT001-P
Fiber-optic, 24 VDC C200H-RT002-P
Wired, 100/200 VAC C200H-RT201
Wired, 24 VDC C200H-RT202
p.84
CPUs
C200HE-CPU11-E
C200HE-CPU32-E C200HE-CPU42-E
C200HG-CPU33-E C200HX-CPU34-E
C200HG-CPU43-E C200HX-CPU44-E
C200HG-CPU53-E C200HX-CPU54-E
C200HG-CPU63-E C200HX-CPU64-E
4
SYSTEM COMPONENTS
SYSMAC NET LINK*
C200HS-SNT32
C200HW-COM06-EC200HW-COM01 C200HW-COM02 C200HW-COM03 C200HW-COM04-E C200HW-COM05-E
DEVICENET
SCANNER
C200HW-DRM21
HOST LINK
RS422 C200H-LK202-V1
Fiber-optic C200H-LK101-PV1
RS232 C200H-RM201-V1
PC LINK
C200H-LK401 PC CARD*
C200HW-PCU01
Ethernet Set*
C200HW-PCS01-E
REMOTE I/O MASTER
Fiber-optic
C200H-RM001-V1
Wired
C200H-RM201-V1
SYSMAC LINK*
Coaxial
C200HW-SLK23/24
Fiber-optic
C200HW-SLK13/14
p.81
DISCRETE I/O MODULES
SPECIAL I/O MODULES
COMMUNICATIONS MODULES
COMMUNICATIONS BOARDS (cannot be mounted to the CPUHE-CPU11-E)
p.14 p.14 p.14 p.14 p.14
p.14
p.85 p.87 p.72 p.83 p.78 p.75
ANALOG INPUT
C200H-AD001
C200H-AD002
p.40
ANALOG OUTPUT
C200H-DA001
C200H-DA002
p.41
ASCII/BASIC
C200H-ASC02
p.62
CAM POSITIONER
C200H-CP114
p.60
FUZZY LOGIC
C200H-FZ001
p.51
HIGH-SPEED
COUNTER
C200H-CT❏❏❏
p.58
RFID SENSOR
C200H-IDS❏❏
p.66
DUAL-AXIS
MOTION CONTROL
C200H-MC221
p.53
PID CONTROL
C200H-PID0
p.48
POSITION
CONTROL
C200H-NC211
C200H-NC112
p.56
TEMPERATURE
SENSOR
C200H-TS❏❏❏
p.42
TEMPERATURE
CONTROL
C200H-TC❏❏❏
C200H-TV❏❏❏
p.44,46
VOICE
C200H-OV001
p.64
B7A INTERFACE
16 points
C200H-B7A1
p.26
B7A INTERFACE
32 points/64 points
C200H-B7A❏❏
(cannot be used on Slave rack)
p.26
HIGH DENSITY INPUT
C200H-ID❏❏❏
Group 2 C200H-ID21
p.29,34
HIGH DENSITY OUTPUT
C200H-OD❏❏❏
Group 2 C200H-OD21
p.30,36
ANALOG TIMER
C200H-TM001
p.31
MIXED I/O
16 inputs/16 outputs
C200H-MD❏❏❏
p.38
INTERRUPT INPUT
C200HS-INT01
(CPU Backplane ONLY)
p.32
12/32 POINT OUTPUT
C200H-O❏❏❏❏
p.22
16/32 POINT INPUT
C200H-I❏❏❏❏
p.22
5/8/16 POINT OUTPUT
C200H-O❏❏❏❏
p.22
8 POINT INPUT
C200H-I❏❏❏❏
p.22
*Use these modules together with communications boards (C200H-COM01/04-E) in the CPU Rack.
5
Backplane
I/O Modules
Special I/O Modules
Communication
Modules CPU
I/O Connecting Cable
Power Supply
Module
CPU Rack
Memory
Cassette
Communications Board
CPU Rack
The CPU Rack is the master controller rack for the control sys-
tems and contains the system communications ports. It may be
expanded using Expansion Racks and Slave Racks.
A fully configured C200HαCPU Rack includes a CPU, Backplane,
Power Supply Module, I/O Modules, Special I/O Modules and
Communication Modules, as appropriate for the application.
A complete system may also include connecting cables and pro-
gramming software or hardware.
A total of two SYSMAC LINK or SYSMAC NET Link Modules can
be mounted to the CPU if the C200HW-COM01 or C200HW-
COM04-E Communications Board is connected to the CPU.
Only two C200HS-INT01 Interrupt Input Modules can be mounted
on a CPU Rack.
NOTE:
SELECT THE APPROPRIATE BACKPLANE FOR THE CPU RACK,
EXPANSION I/O RACK, AND SLAVE RACK. EACH TYPE OF
BACKPLANE IS A DIFFERENT MODEL.
For blackplane dimensions, refer to the
Backplanes
subsection
found later in this section.
To order, refer to the specific information provided
separately in the
Standard Parts section
of this catalog.
6
SYSTEM OVERVIEW
BASIC CONFIGURATION -- C200HX/HG/HE
I/O Modules
Special I/O Modules
Communication Modules
Remote I/O
Slave Module
I/O Modules and
Special I/O Modules
Backplane
Power Supply
Module
Fiber-optic
cable or
twisted-pair
cable
Expansion I/O Racks Slave Racks
Local Expansion Racks
The configuration of an Expansion I/O Rack includes a
Power Supply Module, an Expansion Backplane, and ap-
propriate I/O Modules, Special I/O Modules, and Commu-
nication Modules.
The number of allowable Expansion Racks varies with
CPU model.
Up to three Expansion I/O Racks can be connected to the
C200HX-CPU54-E, C200HX-CPU64-E, C200HG-
CPU53-E, or C200HG-CPU63-E.
Up to two Expansion I/O Racks can be connected to any
other CPU for the C200HX, C200HG, and C200HE.
Different types of Backplanes are necessary for the CPU,
Expansion I/O Rack, and the Slave Rack.
Slave Racks
To expand a system and minimize wiring costs, you may
connect a maximum of five Slave Racks per system.
The Configuration of a Slave Rack includes a Remote I/O
Slave Module, a Backplane (for the C200HX/HG/HE Slave
Rack), I/O Modules, and Special I/O Modules.
To mount a High-density I/O Module to a Slave Rack, use a
C200H-RM001-PV1/RM201.
Note: C200H-RM001-P Master Modules cannot be used.
Group-2 High-density I/O Modules, Communications I/O
Modules, and Interrupt Input Modules cannot be mounted in
Slave Racks.
You can connect a Maximum of two Expansion I/O Racks to
Slave Racks using I/O Connecting Cable.
Always count the Expansion I/O Racks (connected in this
way) against the maximum of five Slave Racks that can be
connected.
7
SYSTEM OVERVIEW
BASIC CONFIGURATION -- C200HX/HG/HE
8
SYSTEM OVERVIEW
C200HX/HG/HE SPECIFICATIONS
C200HαPLC -- System Specifications
ITEM SPECIFICATIONS
Supply voltage AC power supply: 100 to 120/200 to 240 VAC selectable 50/60 Hz
DC power supply: 24 VDC
Operating voltage range AC power supply: 85 to 132/170 to 264 VAC
DC power supply: 19.2 to 28.8 VDC
Power consumption AC power supply: 120 VA max.
DC power supply: 50 W max.
Surge current 30 A max.
Output capacity 4.6A,5VDC;0.6A,26VDC;0.8A,24VDC
+10%/--20% (C200HW-PA204S only)
Insulation resistance 20 Mbetween AC terminals and the GR terminal at 500 VDC (see note 1)
Dielectric strength 2,300 VAC at 50/60 Hz for 1 minute between AC terminals and housing; 1,000 VAC at 50/60 Hz for 1 minute between DC termi-
nals and housing. Leakage current: 10 mA max. (see note 1)
Noise immunity 1,500 Vp-p, pulse width: 100 ns to 1 µs, rise time: 1 ns pulse (by noise simulator)
Vibration 10 to 57 Hz; 0.075 mm amplitude, 57 to 150 Hz; acceleration: 1 G, in X, Y, and Z directions, for 80 minutes each (sweep time 8
min x 10 sweeps = 80 min); (When mounted on DIN track, 2 to 55 Hz, 0.3 G, in X, Y, and Z directions for 20 minutes each)
Shock 15G (147 m/s2) in X, Y, and Z directions, 3 times each
Ambient temperature Operating: 0 to 55°C(32
°to 131.0°F)
Storage: --20 to 75°C (-4.0 to 167.0°F) without battery
Humidity 10% to 90% (without condensation)
Atmosphere Must be free of corrosive gases
Grounding Less than 100
Enclosure rating IEC IP30 (mounted in a panel)
Weight 6 kg max. (CPU: 315 g max., Power Supply Module: 510 g max., Backplane: 445 g to 1040 g)
Note: Besure to disconnect theLG and GR terminals when conductinginsulation resistance tests ordielectric strength tests. Internalcomponents might be damagedif insulation resistancetests are
repeated many times with the LG and GR terminals connected.
Communications Board (C200HW-COM06-E shown here)
LED
Indicators
Memory cassette
DIP switch
Multifunctional
Peripheral port
RS-232C port
SYSMAC C200HX
Programmable Controller
CPU64
Lit when the PLC is operating normally.
Flashes if the PLC in operation detects any
non-fatal error. (The PLC will continue
operating.) Lit if the PLC in operation detects any
fatal error. (The PLC will stop operating. ) After
the PLC stops operating, the RUN indicator will
be off, and all output signals of the Output
Modules will be interrupted.
Lit when the Load OFF flag (AR bit) is ON. (All
output signals of the Output Modules will be
interrupted.)
Flashes when the CPU is communicating with the
device connected to the peripheral port or
RS-232C port.
RUN (green)
ERR (red)
INH (orange)
COMM (orange)
INDICATOR ON THE CPU FUNCTION
Indicators
9
CPU
YOUR INTRODUCTION TO THE C200HX/HG/HE CPU
Features
Select from Eleven C200HαCPUs within Alpha’s
Three Basic Model Types
Each model has different program capacities, processing
speeds, I/O capabilities, communications connections and fea-
tures. (The
C200H
α
CPU Selection Table
is provided later in
this section.)
Optional Back-up Memory Cassettes
For program back-up or rewrite option, each CPU has a special
Memory Cassette compartment.
Multifunctional Peripheral Port
Directly connect to programming peripherals or communicate to
Omron’s Operator Interface Terminals and other third party de-
vices using an optional CIF Convertor Cable.
Built-in RS-232C Port
Direct Host Link communications to the CPU or interface with
other devices through serial communications. Available on se-
lected models only.
Versatile Communications
Install one of six C200HαCommunications Boards to have addi-
tional communications ports. The boards fit into the communica-
tions slot in the CPU and enable communication with SYSMAC
LINK or SYSMAC NET modules, a PC card module or a variety
of serial devices -- including Operator Interfaces. Order the
Communications Board and Memory Cassette separately (not
provided with the CPU).
Protocol Macro
Three C200HαCommunications Boards offer the Protocol Mac-
ro Instruction that controls data transfer with various commu-
nications devices and components equipped with RS-232C or
RS-422/-485 ports. With the Protocol Macro Function built into
the C200HW-COM04, C200HW-COM05-E and C200HW-
COM06-E Communications Boards, communications se-
quences (data transfer procedures) may be modified with Om-
ron’s Protocol Support Software.
Although seven Omron Communications sequences are built-in,
you can use the Protocol Support Software to create other com-
munications sequences. For more details, refer to the
Commu-
nication Board section
that follows.
10
CPU
C200HX/HG/HE CPU SELECTION GUIDE
Consider these Application Needs when Selecting the C200HαCPU
1. What is the required program capacity?
2. Determine total standard I/O (with expansion rack) and Special I/O requirements.
3. What communications interfaces are required?
C200HαCPU Selection Table
PROGRAM
CAPACITY
(WORDS)
DM
(WORDS) EM
(WORDS) BASIC
INSTRUCTION
PROCESSING
TIME
NO.
I/O
PTS.
MAX. NO.
EXPANSION
I/O RACKS)
MAX. NO. HIGH-
DENSITY
I/O MODULES
(GROUP 2)
NO. BELOW = TOTAL
NO. OF MODULES
MAX. NO. OF
SPECIAL I/O
MODULES
(GROUP 1)
NO. = TOTAL NO.
OF MODULES
RS-232C CLOCK
FUNCTION COMMUNICA-
TIONS BOARD
AVAILABLE
PART NUMBER
3.2K 4K None 0.3 µsmin. 640 2Unavailable 10 No No No C200HE-CPU11-E
7.2K 6K 880 10 Yes Yes C200HE-CPU32-E
Yes C200HE-CPU42-E
15.2K 6K 6K 0.15 µsmin. 880 210 10 No Yes Yes C200HG-CPU33-E
Yes C200HG-CPU43-E
1,184 316 (10) 16 (10) No C200HG-CPU53-E
1
6
(
1
0
)
See Note
1
6
(
1
0
)
See Note
Yes C200HG-CPU63-E
31.2K 6K 6K x 3
(
1
8
K
)
0.1 µsmin. 880 210 10 No Yes Yes C200HX-CPU34-E
6
K
x
3
(18K) Yes C200HX-CPU44-E
1,184 316 (10)
S
N
t
16 (10)
S
N
t
No C200HX-CPU54-E
1
6
(
1
0
)
See Note
1
6
(
1
0
)
See Note
Yes C200HX-CPU64-E
Note: When the table indicates a selection total of 16 High-density I/O Modules or Special I/O Modules -- the total of 16 is applicable only if you select from the Modules in
this list:
High-density I/O Modules: C200H-ID216 (32 inputs) and C200H-OD218 (32 outputs).
Special I/O Modules: C200H-AD002, C200H-DA002, C200H-NC211, and C200H-CT021
If your selections are not in the list above: you may be limited to only 10 modules -- as indicated in the table.
An exception: A total of only 8 can be used if you select C200H-OD219, C200H-ID217, or C200H-ID111 High-density I/O Modules.
11
CPU
SPECIFICATIONS, CHARACTERISTICS
C200HαCPU Characteristics
ITEM SPECIFICATIONS
Control method Stored program
I/O control method Cyclic scan with direct output and immediate interrupt processing are both possible.
Programming method Ladder diagram
Instruction length 1 address/instruction, 1 to 4 words/instruction
Number of instructions 14 basic instructions, 231 special instructions
Execution time Basic instructions:
e.g., LD C200HE-CPU

-E:0.3 µs
C200HG-CPU

-E:0.15 µs
C200HX-CPU

-E:0.1 µs
Special instructions:
e.g., MOV(21) C200HE-CPU

-E:1.2 µs
C200HG-CPU

-E:0.6 µs
C200HX-CPU

-E:0.4 µs
Program capacity C200HE-CPU11-E: 3.2K words max.
C200HE-CPU32-E/CPU42-E: 7.2K words max.
C200HG-CPU

-E: 15.2K words max.
C200HX-CPU

-E: 31.2K words max.
I/O bits 640 (00000 to 02915, 30000 to 30915)
IR bits 6,464 (03000 to 23115, 31000 to 51115)
SR bits 1,080 (23200 to 25507, 25600 to 29915)
TR bits 8(TR0to7)
HR bits 1,600 (HR 0000 to 9915)
AR bits 448 (AR 0000 to 2715)
LR bits 1,024 (LR 0000 to 6315)
Timers/Counters 512 (TIM/CNT 000 to 511)
DM words Read/Write: 6,144 (DM 0000 to 6143)
Read-only: 512 (DM 6144 to 6655)
Expansion: Up to 3,000 words max. (DM 7000 to 9999)
EM words Read/Write:
C200HE-CPU

-E: None
C200HG-CPU

-E: 6,144 (EM 0000 to EM 6143)
C200HX-CPU

-E: 6,144
3 banks (EM 0000 to EM 6143)
Power failure backup function Holds HR, AR, CNT, DM, and EM and clock (RTC) contents.
Memory backup time The battery service life is five years at 25°C(77
°F). The service life will be shortened if the battery is used at higher tempera-
tures.
Replace the battery within one week after the battery alarm indicator starts flashing. When replacing the battery, install the new
battery within five minutes after removing the old one.
Self-diagnostic function CPU errors (watchdog timer), I/O verification errors, host link errors, memory errors, battery errors, I/O bus errors, remote I/O
errors, etc.
Program check function Checks the program from the time the program starts running and checks the omission of the END instruction or any other im-
proper instruction. This function allows three-level checking of programs through the Programming Console.
12
CPU
SPECIFICATIONS, CHARACTERISTICS
Comparing C200HαCPU Specifications
Use the following table to compare the functions of the C200HX, C200HG, and C200HE with those of the C200HS and C200H.
FUNCTION C200HX/HG/HE C200HS C200H
Memory User Memory (UM) 3.2K words (C200HE-CPU11-E)
7.2K words (C200HE-CPU
2-E)
15.2K words (C200HG-CPU
3-E)
31.2K words (C200HX-CPU
4-E)
15.2K words 3.2K words/7.2K words
Normal Data Memory (DM) C200HX/G: 6,144 words (DM 0000 to DM 6143)
(DM 4000 to DM 5999 do not exist in the C200HE-
CPU11-E) C200HE-CPU16: 4000 words (DM0000-3999)
6,144 words (DM 0000 to
DM 6143) 1,000 words (DM 0000 to
DM 0999)
Fixed Data Memory 512 words (DM 6144 to DM 6655) 512 words (DM 6144 to
DM 6655) 1,000 words (DM 1000 to
DM 1999)
Fixed Expansion Data Memory 0 to 3,000 words (DM 7000 to DM 9999) 0to3,000words
(DM 7000 to DM 9999) None
Extended Data Memory (EM) C200HE: No EM
C200HG: 6,144 words x 1 bank
C200HX: 6,144 words x 3 banks
None None
I/O Expansion Racks 3 max. (2 max. for C200HE-CPU

-E and C200HG/HX-
CPU-3
-E/4
-E) 2max. 2max.
Group-2 High-density I/O Mod-
ules 0 to 9 and A to F Modules per PLC
C200HE-CPU11-E: No Group-2 Modules connected
C200HE-CPU
2-E, C200HG/HX-CPU-3
-E/CPU4
-E:
0to9UnitsperPLC
0 to 9 Modules per PLC 0 to 9 Modules per PLC
Special I/O Modules 0 to 9 and A to F Modules per PLC
C200HE-CPU

-E, C200HG/HX-CPU-3
-E/CPU4
-E: 0
to 9 Modules per PLC
0 to 9 Modules per PLC 0 to 9 Modules per PLC
Execution
time Basic instructions (LD) 0.1 µs (C200HX)
0.15 µs (C200HG)
0.3 µs (C200HE)
0.375 µs0.75 µs
Special instructions (MOV) 0.4 µs (C200HX)
0.6 µs (C200HG)
1.2 µs (C200HE)
19 µs88 µs
Other special instructions C200HX and C200HG: Approx. 1/3 to 2/3 of the time
required by the C200HS.
C200HE: Approx. 3/4 to 4/5 of the time required by the
C200HS.
--- ---
END processing time 0.7 ms (C200HX/HE-CPU
2-E)
2.1 ms (C200HE-CPU11-E) 0.7 ms 2.8 to 3.5 ms
CPU RS-232C port C200HX/HG/HE-CPU2
-E/4
-E/6
-E C200HS-CPU2
-E/3
-E None
Clock function All models except the C200HE-CPU11-E. All models Incorporated by the
Memory Module
SYSMAC LINK Module and
SYSMAC NET Link Module
connection
C200HW-COM01 and C200HW-COM04-E Communications
Boards available for connection except the C200HE-
CPU11-E.
C200HS-CPU3
-E C200H-CPU11-E/31-E
Communications Board The Communications Board can be mounted to all CPUs
except the C200HE-CPU11-E. The following are possible
with the Communications Board:
Use of the SYSMAC LINK Module and SYSMAC NET Link
Module expansion of up to 2 communications ports, and use
of a protocol macro function
None None
Interrupts Interrupt Input Modules 2 (16 points) 1 (8 points) None
Interruption with Communica-
tions Board Possible --- ---
Response time Same as the C200HS.
1 ms if the C200HW-SLK

is used. C200H-compatible mode:
10 ms
C200H mode: 1 ms
The C200HS in any mode
connected to the SYS-
MAC LINK Module or
SYSMAC NET Link
Module 10 ms
---
SYSMAC
LINK Service time 3.5 ms max. (1 system) 10.8 ms max. (1 system) 11.5 ms max. (1 system)
Remote programming Via the peripheral port, RS-232C port, and Communications
Board Via the peripheral port
only ---
Influence on interrupt response
performance None 10 ms is required by the
C200HS in any mode. ---
13
CPU
SPECIFICATIONS, CHARACTERISTICS
User Memory Area
The C200HX, C200HG, and C200HE have a User Memory (UM) area allocation function. This function allows the use of the ladder pro-
gram area of the UMas a fixed expansion DMarea and I/Ocomment area.The function is enabled with theSYSMAC Support Software
(SSS), SYSWIN, or the Programming Console. Only SSS can be used to designate any part of the ladder program area as an I/O com-
ment area (i.e., the Programming Console cannot be used to designate any part of the ladder program area as an I/O comment area.
C200HX/HG/HE Memory Area Structure
DM 0000
DM 1000
DM 2599
DM 6000
DM 6144
DM 6600
DM 6655
DM 7000
DM 9999
Normal Data Memory (DM) 6,144 words Fixed DM (512
words)
Special I/O
Module
default area
Error
log
area
PLC
Setup
area
System
reserved
area
Fixed
expansion
DM area
(0 to 3,000
words)
I/O
comment
area
Ladder program area
Possible ROM area
Built-in UM (32K words max.)
Ladder program
area A user program is stored in the ladder program area. If part of the UM is used as a fixed expansion DM area or I/O comment area, the capacity
of the ladder program area storing the user program will be reduced accordingly.
I/O comment area I/O comments are stored in the I/O comment area. The I/O comments can be stored with a program. The I/O comments can be monitored
without
loading the comment, just as with conventional comments.
Fixed expansion DM
area The default values of the Special I/O Module, Programmable Terminal, the character string of the Programmable Terminal, and operation data
are stored in the fixed expansion DM area. By changing the I/O monitor present value of the Programming Console or using the DM edit transfer
operation of the Ladder Support Software, the default values can be written to DM 7000 to DM 9999.
System reserved
area The system reserved area is used by the system only.
PLC Setup area The settings required for the operation of the PLC are stored in the PLC Setup area.
Normal DM area The user can freely use the normal DM as a data area for arithmetic operations. If the Special I/O Module is used, DM 1000 to DM 2599 will be a
Special I/O Module default area.
DM 1000 to DM 2599 can be used as a normal DM if DM 7000 to DM 8599 are set as a Special I/O Module default area with the PLC Setup. DM 6000 to DM 6030 are used
exclusively as an error log area.
Unlike the normal DM area, nothing can be written to the fixed expansion DM area using ladder programming.
The capacity of a ladder program will decrease if the size of the fixed expansion DM area and the total capacity of the I/O comments increase.
TheC200HX,C200HG,andC200HE donothaveafixedexpansionDMareaorI/Ocommentareabeforeshipping.TheusermustallocatetheseareasintheUMaccordingto
the application.
C200HW-COM04-E
Bus
connector
Bus
connector
Port A
(RS-232C)
Indicators
C200HW-COM01 C200HW-COM02
C200HW-COM05-E
Indicators
Port B
(RS-232C)
Port A
(RS-232C)
C200HW-COM03
Indicators
Port A
(RS-422/485)
C200HW-COM06-E
Indicators
Port B
(RS-232C)
Indicators
Memory
Cassette
CPU
Communications
Board
Note: Order the Communications Board and Memory
Cassetteseparately(notprovided with theCPU).
Port A
(RS-232C)
Port A
(RS-422/485)
Indicators
14
COMMUNICATIONS BOARDS
SPECIFICATIONS, SELECTION GUIDE
The C200Hαoffers the industry’s most versatile PLC commu-
nications options. With six Communications Board options, you
can select just the right communications for your application.
The boards fit into the communications slot in the CPU and let
you expand the PLC functionality by connecting to other PLCs
or computers with Omron’s SYSMAC LINK, SYSMAC NET or, a
PC Card Module. A variety of serial ports let you connect to
Operator Interfaces, PCs, or other serial communication de-
vices.
Specifications
PART NUMBER DESCRIPTION
C200HW-COM01 CPU connection when using SYSMAC LINK or
SYSMAC NET Link Communications Modules
C200HW-COM02 One RS-232C port
C200HW-COM03 One RS-422/485 port
C200HW-COM04-E CPU connection for the SYSMAC LINK Module or
SYSMAC NET Link Module, and an RS-232C
port, with a protocol macro function
C200HW-COM05-E Two RS-232C ports with a protocol macro
function
C200HW-COM06-E One RS-422/485 port, and one RS-232C port,
with a protocol macro function
Communications Board Indicators
INDICATOR COLOR STATUS MEANING FUNCTION
RDY Green Not lit Board not
ready for
use
Hardware error
Flashes Setting error System setting or
protocol data error
Lit Board ready
for use Normal operation
COMB Orange Flashes Communi-
cating Port B is in use for
communication
COMA Port A is in use for
communication
C200HW-ZW3AT1-E
Protocol Support Software:
The Protocol Macro software
is used to set or customize
protocol macro data.
C200HX/HG/HE
C200HW-COM04-E/05-E/06-E Communications Board
(with protocol macro function)
Standard measuring devices,
components, and personal
computers
RS-232C
Asynchronous (start-stop synchronization) communication
Modem
Visual Inspection
System
Intelligent Signal
Processor
Temperature
Controller
Bar code
reader
ID Controller
OMRON’s peripheral devices (equipped with standard communications sequences)
IBM PC/AT or
Compatible
15
COMMUNICATION BOARDS
PROTOCOL MACRO
The Protocol Macro instruction permits easy interfacing of C200Hα
CPUs with peripheral devices. In cases where ASCII/BASIC Mod-
ules have been used to interface with peripheral devices, the Proto-
col Macro instruction now offers an extremely automated method.
The Protocol Macro instruction is a communications protocol that
controls data transfer using various devices and components
equipped with RS-232C or RS-422/485 ports -- thus, replacing
ASCII/BASIC Modules and the difficult associated programming
procedures. The C200HαCommunications Boards COM04-E,
COM05-E, and COM06-E have a built-in Protocol Macro capability,
providing seven Omron communications protocols. The data trans-
fer procedures may be modified with Omron’s Protocol Support
Software. Communications sequences are executed from the lad-
der program with the Protocol Macro Instruction (PMCR).
Features
The C200HαCommunications Boards COM04-E, COM05-E, and
COM06-E (with protocol macro capability built-in) offer these seven
standard communications sequences:
1. Temperature Controller Sequence E5
J, E5
K, ES100
,
and E5ZE
2. Intelligent Signal Processor Sequence K3TH, K3TR, K3TX,
and K3TC
3. Bar Code Reader Sequence V500 and V520
4. Laser Micrometer Sequence 3Z4L
5. Visual Inspection System Sequence F200, F300, and F350
6. ID Controller Sequence V600
7. Hayes AT Command (Modem) Sequence ME 1414BZ,
MD 24FB10V, and MD 144FB5V
Or, use the Protocol Support Software to create Communications
sequences other than those listed.
C200HX/HG/HE
RS-232C
port B
Simple
communications
sequence
RS-232C
port A Device with
RS-232C
interface
15 m
RS-232C
C200HX/HG/HE
RS-232C port BRS-422/485 port A
15 m
Temperature Controller
RS-422/485
Temperature Controller
Temperature Controller
Temperature Controller
Temperature Controller
500 m
(With an RS-422 and RS-485
communications function)
16
COMMUNICATION BOARDS
PROTOCOL MACRO
System Configuration Examples
RS-232C (C200HW-COM05-E)
An RS-232C line connects the C200HW-COM05-E and a
device, allowing the RS-232C line to be a maximum of 15 m.
RS-422/485 (C200HW-COM06-E)
The C200HW-COM06-E connects to one or more devices
through the RS-422 and RS-485 port provided the RS-422 or
RS-485 line between the C200HW-COM06-E and the farthest
device is a maximum of 500 m.
EEPROM
Memory Cassette
EPROM
Memory Cassette
17
MEMORY CASSETTES
SPECIFICATIONS
EEPROM or EPROM
Memory Cassettes
Each C200HαCPU can accept a Memory Cassette to provide
back-up or downloading of programs and data. EEPROM mod-
els allow the program to be downloaded to and from the CPU
memory. EPROM models allow the user to write to an EPROM
and insert it into the memory cassette.
EEPROM Memory Cassette --
No Back-up Power Supply Required
The EEPROM Memory Cassette can be installed in the
C200HX, C200HG, and C200HE CPUs to write and read pro-
grams and I/O data to the CPU.
Because the EEPROM Memory Cassette does not require any
backup power supply, it will retain its data even after it is dis-
connected from the CPU.
EEPROM Memory Cassette Capacity
CAPACITY PART NUMBER
4K words C200HW-ME04K
8K words C200HW-ME08K
16K words C200HW-ME16K
32K words C200HW-ME32K
EPROM Memory Cassette --
Use a Standard PROM Writer to Write a Program
Connect an EPROM to the EPROM Memory Cassette before
installing the EPROM Memory Cassette into the CPU.
An EPROM Memory Cassette will lose its data if it is discon-
nected from the CPU.
EPROM Memory Cassette Capacity
DESCRIPTION CAPACITY PART NUMBER
Cassette 16K words/32K words C200HS-MP16K
EPROM (Order
R
O
M
S
t
l
)
Equivalent to 27256 ROM-JD-B
E
R
O
M
(
O
r
d
e
r
ROM Separately) Equivalent to 27512 ROM-KD-B
C200HW-P

18
POWER SUPPLY MODULES
CAPACITIES AND SPECIFICATIONS
All CPU Racks and Expansion Racks feature
separate Power Supplies that may be re-
placed individually to meet system require-
ments without having to replace the other
components. The Power Supply provides
power for the CPU and Modules on the Rack.
Choose an AC or DC version. Model
C200HW-PA204Scomes with built-in 24 VDC
Power Supply that may be used to power
Special I/O Modules, Sensors, or other de-
vices, eliminating the need for a separate
Power Supply.
Power Supply Modules Available
SUPPLY VOLTAGE COMMENTS PART NUMBER
100 to 120 VAC
2
0
0
t
2
4
0
V
A
C
--- C200HW-PA204
1
0
0
t
o
1
2
0
V
A
C
200 to 240 VAC With 24-VDC service
power supply C200HW-PA204S
24 VDC --- C200HW-PD024
19
BACKPLANES
SPECIFICATIONS
Select the Appropriate Backplane for the CPU
with its I/O Modules
When selecting Backplanes for the CPU, the Expansion I/O,
and the Slave Rack(s), each type of Backplane is a different
model number. To order, refer to the specific information pro-
vided separately in the
Standard Parts section
of this catalog.
Dimensions
CPU I/O Backplane
C200HW-BC

Unit: mm (inch)
130
(5.12)
130
(5.12) 118
(4.65)
118
(4.65)
W1
W2
NO. OF SLOTS W1 W2 PART NUMBER
3slots 246 (9.69) 260 (10.24) C200HW-BC031
5slots 316 (12.44) 330 (12.99) C200HW-BC051
8slots 421 (16.57) 435 (17.13) C200HW-BC081
10 slots 491 (19.33) 505 (19.88) C200HW-BC101
Expansion I/O Backplane
C200HW-BI

Unit: mm (inch)
130
(5.12)
130
(5.12)
118
(4.65)
118
(4.65)
W1
W2
NO. OF SLOTS W1 W2 PART NUMBER
3slots 175 (6.89) 189 (7.44) C200HW-BI031
5slots 245 (9.65) 259 (10.20) C200HW-BI051
8slots 350 (13.78) 364 (14.33) C200HW-BI081
10 slots 420 (16.54) 434 (17.09) C200HW-BI101
20
BACKPLANES
SPECIFICATIONS
Slave Rack Backplane
C200H-BC

-V2
Unit: mm (inch)
130
(5.12)
130
(5.12) 118
(4.65)
W1
W2 118
(4.65)
NO. OF SLOTS W1 W2 PART NUMBER
3slots 246 (9.69) 260 (10.24) C200H-BC031-V2
5slots 316 (12.44) 330 (12.99) C200H-BC051-V2
8slots 421 (16.57) 435 (17.13) C200H-BC081-V2
10 slots 491 (19.33) 505 (19.88) C200H-BC101-V2
I/O Connecting Cables
21
CONNECTING I/O CABLES
FEATURES, CAPACITIES AND SPECIFICATIONS
I/O Connecting Cables connect a CPU Rack to an Expansion
I/O Rack or an Expansion I/O Rack to another Expansion I/O
Rack. The following five types of I/O Connecting Cables are
available. The total length of the I/O Connecting Cables used in
a configuration must be 12 m maximum.
Note: Count the Expansion I/O Racks (connected in this way) against the
maximum of five Slave Racks that can be connected.
Select from Five I/O Connecting Cables
CABLE LENGTH (CM) PART NUMBER
30 C200H-CN311
70 C200H-CN711
200 C200H-CN221
500 C200H-CN521
1,000 C200H-CN131
Note: The total length of the I/O Connecting Cables used in a network must not
exceed 12 m.
LOT No.
OMRON Corporation MADE IN JAPAN
LOT No.
OMRON Corporation MADE IN JAPAN
NK APP. <88A120>
Connector
Style C
C200H--OA121--E
OUTPUT UNIT
29XOFLOT No.
OMRON Corporation MADE IN JAPAN
NK APP. <88A120>
Connector
Style D
NK APP. <88A120>
Connector
Style A
C200H--OC222
OUTPUT UNIT
02X2F
LOT No.
OMRON Corporation MADE IN JAPAN
NK APP. <88A120>
Connector
Style B
Connector
Style E
Discrete I/O Modules -- Varying Connector Types
22
DISCRETE I/O MODULES
OVERVIEW
Discrete I/O modules are available in a number of voltages,
densities, terminal block, and connector types. Connector-style
high-density I/O modules with 32 or 64 discrete I/O points per
module have solder connectors included with the module. Op-
tional wiring methods are available using Omron’s I/O blocks,
screw terminal, crimp and ribbon connectors, and pre-termi-
nated cables. These versatile high-density configuration options
minimize rack space and wiring time. The Omron I/O Blocks
provide single-point isolation and up to 5 A current capacity per
point. Replaceable relays and solid-state plug-in modules allow
easy maintenance. There are five styles of discrete I/O modules
in the C200H family. The profiles of each are shown here. Each
module in the following pages is cross-referenced to the module
style. Modules include the appropriate connectors.
Features
Versatile high-density configuration options minimize rack
space and wiring time
Replaceable relays and solid-state plug-in modules mean
easy maintenance
23
DISCRETE I/O MODULES
INPUT MODULE SPECIFICATIONS
Input Module Specifications
TYPE NO. OF
INPUTS INPUTS PER
COMMON INPUT VOLTAGE INPUT
CURRENT OPERATING
VOLTAGE INPUT RESPONSE TIME MODULE-
STYLE PART NUMBER
ON OFF ON OFF
AC Input 8pts 8pts. 100 to 120 VAC
+
1
0
%
/
--
1
5
%
10 mA,
1
0
0
V
A
C
60 VAC
m
i
n
20 VAC
m
a
x
35 ms
m
a
x
55 ms
m
a
x
AC200H-IA121
16 pts. 16 pts. +
1
0
%
/
--
1
5
%
1
0
0
V
A
C
m
i
n. max. max. max. BC200H-IA122
8pts. 8pts. 200 to 240 VAC
1
0
%
/
1
5
%
10 mA,
2
0
0
V
A
C
120 VAC
i
40 VAC AC200H-IA221
16 pts. 16 pts.
2
0
0
t
o
2
4
0
V
A
C
+10%/--15%
1
0
m
A
,
200 VAC
1
2
0
V
A
C
min.
4
0
V
A
C
max. BC200H-IA222
DC Input 8pts. 8pts. 12 to 24 VDC
+10%/--15% 10 mA,
24 VDC 10.2
VDC
min.
3.0 VDC
max. 1.5 ms
max. 1.5 ms
max. AC200H-ID211
16 pts. 16 pts. 24 VDC
+10%/--15% 7mA,
24 VDC 14.4
VDC
min.
5.0 VDC
max. BC200H-ID212
AC/DC
Input 8pts. 8pts. 12 to 24 VAC/DC
+10%/--15% 10 mA,
24 VDC 10.2
VDC
min.
3.0 VDC
max. 15 ms
max. 15 ms
max. AC200H-IM211
16 pts. 16 pts. 24 VAC/DC
+10%/--15% 7mA,
24 VAC/
DC
14.4
VDC
min.
5.0 VDC
max. BC200H-IM212
Note: 1. All models feature photocoupler isolation and LED indicator.
2. Each Discrete I/O Module hasa removable terminal block.See the above
STYLE
columnforareference tothemodulestyle/connectortypeandrefertotheaccom-
panying drawing and chart for specific connector details.
Input Module Circuit Configuration
DC Input: ID211, ID212AC Input: IA121, IA122, IA221, IA222
IN
COM
IN
COM
CR2
R1
ID211: 2 k12 to 24
ID212: 3 kΩ24
R
910
~
IA121, IA122: 330 k0.33 µF 470 100to120
IA221: 680 k0.15 µF 820 200to 240
IA222: 680 k0.15 µF 680 200to 240
CR
2
R1
0.01 µF
18 k
Internal circuits
Internal circuits
++
AC/DC Input: IM211, IM212
IN
COM
IM211: 2 k12 to 24 VAC/DC
IM212: 3 k24 VAC/DC
R
0.01 µF
18 k
Internal circuits
++~
V(AC)
RV
R V (DC)
24
DISCRETE I/O MODULES
OUTPUT MODULE SPECIFICATIONS
Output Module Specifications
No. of
outputs Rated load
voltage Max. load
current Min.
switching
capacity
Output
response
times
Leakage
current Outputs/
per common Fuse External
power
supply
Internal power
consumption
(VDC)
Part number
ON OFF
Relay Output Relay Output
8pts. 250 VAC
(cos φ=1)/
250 VAC
(
0
4
)
/
2 A/pt.
8A/8pts. 10 mA,
5VDC 10
ms
max.
10
ms
max.
--- 8pts. --- --- 10 mA max. C200H-OC221
12 pts.
2
5
0
V
A
C
(cos φ=0.4)/
24 VDC max. 2 A/pt.
8A/12pts. 12 pts. C200H-OC222
(see note)
16 pts. 2 A/pt.
8A/16pts. 16 pts. 50 mA max. C200H-OC225
(see note)
5pts. 2 A/pt.
10 A/5 pts. 1pt. 10 mA max. C200H-OC223
8pts. 2Apts.
16 A/8 pts. C200H-OC224
Triac Output Triac Output
8pts. 120 VAC 1 A/pt.
4A/8pts. Resistive
load:
1
0
A
1ms
max. 1/2 of
load
f
3mAmax.,
100 VAC;
6
A
8pts. 5A 140 mA max. C200H-OA121-E
12 pts. 250 VAC,
50/60 Hz 0.3 A/pt.
2 A/12 pts.
l
o
a
d
:
10 mA;
inductive
load: 40 mA
(10 VAC)
1/2 of
load
fre-
quen-
cy
max.
l
o
a
d
fre-
quen-
cy
max.
1
0
0
V
A
C
6mAmax.,
200 VAC 12 pts. 3A 200 mA max. C200H-OA222V
8pts. 1.2 A/pt.
4A/8pts. Resistive
load:
100 mA;
inductive
load: 50 mA
(10 VAC)
1ms
max. 8pts. 5A 180 mA max. C200H-OA223
12 pts. 0.5 A/pt.
2 A/12 pts. 100 mA,
10 VAC;
50 mA,
24 VAC;
100 mA,
100 VAC
1/2 +
1ms
of
load
fre-
quen-
cy
max.
1.5 mA
max.,
120 VAC;
3mAmax.,
240 VAC
12 pts. 3.15 A 270 mA max. C200H-OA224
Transistor Output Transistor
Output
8pts. 12 to 48 VDC
+10%/--15% 1 A/pt.
3A/8pts. Residual
voltage:
1.4 V max.
0.2
ms
max.
0.3
ms
max.
0.1 mA
max. 8pts. 5A 30 mA, 12
to 48 VDC
min.
140 mA max. C200H-OD411
24 VDC
+10%/--15% 2.1 A/pt.
5.2 A/8 pts.
1
.
4
V
m
a
x
.
8A 30 mA, 24
VDC min. C200H-OD213
0.8 A/pt.
2.4 A/8 pts. Residual
voltage:
1.5 V max.
1ms
max. 1ms
max. 1mAmax. None 150 mA, 24
VDC min. C200H-OD214
5to24VDC 0.3 A/pt. 10 mA,
5VDC 1.5
ms
max.
2ms
max. 0.1 mA
max. 5to
24 VDC 10 mA max. C200H-OD216
12 pts. 24 VDC
+10%/--15% 0.3 A/pt.
2A/12 pts. Residual
voltage:
1.4 V max.
0.2
ms
max.
0.3
ms
max.
12 pts. 5A 25 mA, 24
VDC min. 160 mA max. C200H-OD211
16 pts. 0.3 A/pt.
4.8 A/12 pts
1
.
4
V
m
a
x
.
16 pts. 8A 35 mA, 24
VDC min. 180 mA max. C200H-OD212
12 pts. 5to24VDC 0.3 A/pt. 10 mA,
5VDC 1.5
ms
max.
2ms
max. 12 pts. None 5to
24 VDC 10 mA max. C200H-OD217
16 pts. 24 VDC
+10%/--15% 1 A/pt.
4 A/16 pts. Residual
voltage:
0.8 V max.
0.1
ms
max.
0.3
ms
max.
16 pts. 35 mA, 24
VDC min. 160 mA max. C200H-OD21A
Note: Do not exceed the load current of 8 A per common. No more than 8 outputs can be turned ON simultaneously.
25
DISCRETE I/O MODULES
OUTPUT MODULE SPECIFICATIONS
Output Module Circuit Configuration
Relay Output:
OC221, OC222, OC223, OC224, OC225
Triac Output: OA223, OA224 Transistor Output: OD411/OD211
Transistor Output: OD213/OD212 Transistor Output (Source Type): OD214
Use either + or -- VDC
Internal circuits Internal circuits
Internal circuits
Internal circuits
Internal circuits
L
X
L
L
LL
COM
OUT
OUT
OA224: no fuse blowout detector
COM
OUT
COM
+V
Fuse blowout
detector
Fuse blowout
detector
OUT
COM
+V
Fuse blowout
detector
OUT
COM
+V
“F”
LED
OD211: no fuse blowout detector
24 VDC
Internal circuits
L
OUT
COM 5to
24 VDC
Output
indicator LED
Transistor Output (Protective Circuit for Load
Short-circuit): OD216/OD217
Output indicator
LED
Output indicator
LED
Source
driver
++
+
++
+
Alarm output LED
Reset switch
OD212: No fuse blowout detector
+
L
250 VAC max.
“F”
LED
Fuse
“F”
LED
Fuse
Fuse
Output indicator
LED
Transistor Output (Source Type with Protective
Circuit for Load Short-circuit): OD21A
Triac Output: OA222V, OA121-E
L
Internal circuits
L
+
24 VDC
OUT00
OUT15
ALARM
COM
+VRESET
LED
Internal circuits
L
COM
OUT
OA222V: no fuse blowout detector
Fuse blowout
detector
Note: Fuse blowout detection circuit: The F indicator is lit and the 08 bit turns ON. The 08 to 15 bits cannot be used as ordinary IR bits.
C200H-B7Al1
(16 Input Points)
C200H-B7AO1
(16 Output Points)
C200H-B7A02
(32 Output Points)
C200H-B7A12
(32 Input Points)
C200H-B7A21
(16 Input and
16 Output Points)
C200H-B7A22
(32 Input and
32 Output Points)
26
SPECIAL I/O MODULES
B7A INTERFACE MODULES
The C200H-B7A Interface Modules reduce wiring from 16 input
devices or 16 output devices to a few wires. The B7A allows
you to remotely connect I/O that would have required direct con-
nection to the PLC. You save control panel space, wiring time,
and man-hours required for installation. These modules can be
used with the full range of B7A input and output blocks for 16
I/O. The modules require a power supply, as do the terminal
blocks.
Features
ConnectdirectlytotheB7AI/Oblocksusingatwo-conductor
wire
Transmission distance up to 500 m max.
27
SPECIAL I/O MODULES
B7A INTERFACE MODULES
System Configuration
C200HX/HG/HE
B7A Link Terminals
Input
Output
Input
Output
OutputInput
Input Input Output Output
B7A input 32 pts./output 32 pts.
B7A input 16 pts./output 16 pts.
B7A output 32 pts.
B7A input 32 pts.
Note: Refer to the
B7A Link Terminals Datasheet
(Q101)
for more details.
28
SPECIAL I/O MODULES
B7A INTERFACE MODULE
Performance Specifications
PART NUMBER C200H-B7AI1 C200H-B7AO1 C200H-B7A12 C200H-B7A02 C200H-B7A21 C200H-B7A22
B7A INTERFACE MODULES GROUP-2 B7A INTERFACE MODULES
I/O points 16 points or 15
points and 1 error
input
16 output points 32 input points or
30 input points and 2
error inputs
32 output points 16 output points and
16 input points or
15 input points + 1
error input
32 output points and
32 input points or
30 input points + 2
error inputs
Transmission distance 500 m max. if power is supplied to the
Interface Module and B7A Link Terminal
separately.
100 m max. if power is supplied to the
Interface Module and B7A Link Terminal
from a single power supply.
Standard:
500 m max. using separate power supplies.
100 m max. using a common power supply.
High-speed:
100 m max. using separate power supplies.
50 m max. using a common power supply.
If shielded cable is not used, the maximum transmission distance is 10 m regardless of
whether a common or separate power supplies are used.
Transmission delay 19.2 ms typical, 31 ms max. Standard: 19.2 ms typical, 31 ms max.
High-speed: 3 ms typical, 5 ms max. (see note 1)
Internal current
consumption 5 VDC, 100 mA max.
External power supply
(
t
2
)
12 to 24 VDC ±10%
E
t
e
r
n
a
l
o
w
e
r
s
u
l
y
(see note 2) 0.01 A min. 0.03 A min. 0.05 A min. 0.06 A min. 0.05 A min. 0.08 A min.
Weight 200 g max. 300 g max.
Word allocations Same as I/O Modules (in order mounted). The words allocated to Group-2 B7A Interface Modules are determined by I/O number set on
the Modules. Words 030 to 049 allocated according to I/O number setting. Modules with 32
I/O points are allocated two words; Modules with 64 I/O points are allocated four words.
Note: 1. The transmission delay is changed by using the DIP switch.
2. The value of the external power supply does not include the value required by the B7A Link Terminal.
Connectable B7A Link Terminals
Input Terminals
TYPE TRANSMISSION DELAY PART NUMBER
Screw terminals Standard (19.2 ms) B7A-T6
1
S
r
e
w
t
e
r
m
i
n
a
l
s
S
a
n
d
a
r
d
(
1
9
.
2
m
s
)
B7AS-T6
1
High-speed (3 ms) B7A-T6
6
H
i
g
h
s
e
e
d
(
3
m
s
)
B7AS-T6
6
Modular Standard (19.2 ms) B7A-T6D2
M
o
d
u
l
a
r
High-speed (3 ms) B7A-T6D7
PLC connectors Standard (19.2 ms) B7A-T
E3
P
C
c
o
n
n
e
c
t
o
r
s
High-speed (3 ms) B7A-T
E8
Output Terminals
TYPE TRANSMISSION DELAY PART NUMBER
Screw terminals Standard (19.2 ms) B7A-R6

1
S
r
e
w
t
e
r
m
i
n
a
l
s
S
a
n
d
a
r
d
(
1
9
.
2
m
s
)
B7AS-R6

1
High-speed (3 ms) B7A-R6

6
H
i
g
h
s
e
e
d
(
3
m
s
)
B7AS-R6

6
Modular Standard (19.2 ms) B7A-R6A52
M
o
d
u
l
a
r
High-speed (3 ms) B7A-R6A57
PLC connectors Standard (19.2 ms) B7A-R
A
3
P
C
c
o
n
n
e
c
t
o
r
s
High-speed (3 ms) B7A-R
A
8
C200H-ID216
(32 DC input pts.) C200H-ID217
(64 DC input pts.)
29
SPECIAL I/O MODULES
HIGH-DENSITY INPUT MODULE SPECIFICATIONS (GROUP-2)
The High-density Input Modules let you pack more input points
into a single I/O slot for greater space savings. These modules
do not use standard I/O points. Thus, they increase the overall
I/O capacity. They provide 32 or 64 discrete input points. The
modules can be used with Omron’s Terminal Blocks, reducing
wiring between control panels, as well as within control panels.
Features
Easy cable connection to Omron’s XW2B-
Terminal
Blocks using XW2Z-
Connecting Cable. Refer to the
Standard Parts
section for detailed ordering information.
Up to ten 64-point modules or 32-point modules per PLC
Note: The ambient temperature affects the number of points that can
be ON simultaneously.
Specifications
PART NUMBER C200H-ID216 C200H-ID217
Number of inputs 32 points 64 points
Rated input voltage 24 VDC +10%/--15%
Input current 4.1 mA typical at 24 VDC
Input impedance 5.6 k
ON voltage 14.4 VDC min.
OFF voltage 5.0 VDC max.
Input ON delay 1.0 ms max.
Input OFF delay 1.0 ms max.
Isolation Photocoupler
Input indicator LED
External connections Connector
Number of circuits (see
note) 32 points with one
common 64 points with two
commons
Internal power consump-
tion 100 mA max. at
5VDC 120 mA max. at 5
VDC
Weight 180 g max. 250 g max.
Manual W302
Circuit Configuration
COM
IN00
IN07
IN08
IN15
to
to
COM
A/B
COM
IN00
to
IN07
COM
IN08
to
IN15
COM
IN00
to
IN07
IN08
to
IN15
1000 PF
Input indicator
A
B
CN1/CN2
5.6K
680
B
1000 PFA
CN1
Input indicator
SW
CN2
Internal circuits
Internal circuitsDisplay switch
ID217
ID111: 820 2.7 k
ID217: 680 5.6 k
AB
ID216
Note: 1. The polarity of the input power supply source can be positive or negative provided that the
polarity of each common is the same.
2. Although each COM is internally connected, wire them all.
3. The mountable number of High-density I/O Modules varies with the CPU. No High-density
I/O Module can be mounted to the Slave Rack.
C200H-OD218
(32 DC output pts.) C200H-OD219
(64 DC output pts.)
30
SPECIAL I/O MODULES
HIGH-DENSITY OUTPUT MODULE SPECIFICATIONS (GROUP-2)
Using the High-density Output Modules, you pack more output
points into a single I/O slot for greater space savings. These
modules increase the overall I/O capacity, while not using stan-
dard I/O points. They provide 32 or 64 discrete output points.
The modules can be used with Omron’s Terminal Blocks and
Cables, reducing wring between control panels, as well as with-
in control panels.
Features
EasycableconnectiontoOmron’sXW2B-
TerminalBlocks
using XW2Z-
Connecting Cable. Refer to the
Standard
Parts
section for detailed ordering information.
Up to ten 64-point modules or 32-point modules per PLC
Specifications
PART NUMBER C200H-OD218 C200H-OD219
Number of outputs 32 points 64 points
Max. switching capacity 16 mA at 4.5 V to 100 mA at 26.4 V
Leakage current 0.1 mA max.
Residual voltage 0.8 V max.
Input ON delay 0.1 ms max.
Input OFF delay 0.4 ms max.
Output indicator LED
External connections Connector
Number of circuits 32 points with one
common 64 points with two
commons
Fuse (see note) 3.5 A (one/common)
External power supply 110 mA (3.4 mA per ON
pt)min.at5to24VDC
±10%
220 mA (3.4 mA per ON
pt) min. at 5 to 24 VDC
±10%
Internal power
consumption 180 mA max. at 5 VDC 260 mA max. at 5 VDC
Manual W302
Note: The fuse is not user replaceable.
Circuit Configuration
OD218 OD219
Fuse
3.5A
4.5 to 26.4 VDC
OUT00
to
OUT07
4.5 to 26.4 VDC
OUT08
to
OUT15
COM
COM
4.5 to 26.4 VDC
OUT00
to
OUT07
COM
4.5 to 26.4 VDC
OUT08
to
OUT15
COM
A
B
Fuse
4.5 to 26.4 VDC
OUT00
to
OUT07
4.5 to 26.4 VDC
OUT08
to
OUT15
COM
COM
CN1
CN2
SW
CN1/
CN2
Output in-
dicator
F indicator
Output in-
dicator
Output in-
dicator
F indicator
Internal circuits
Fuse
break
detec
tor
Internal circuits
Display
switch/
fuse
break
detector
Note: ThenumberofGroup-2High-densityOut-
put Modules is limited by the CPU model.
TheycannotbeusedwiththeSlaveRack.
C200H-TM001
C4K-CN223
(2 m)
External adjustments
mounted as required by
application.
C200HX/HG/HE
System Configuration
31
SPECIAL I/O MODULES
ANALOG TIMER MODULE
The Analog Timer Module lets the user fine-tune timer values
manually, without going into the PLC program. Adjustments can
be made from the front part of the module or from remote loca-
tions (using a special cable and external variable resistors).The
module has four independently set and monitored timers that
each have variable ranges. The user may select, by DIP switch,
for each point to use front panel variable resistor or external
variable resistors. Through internal bit allocation, each timer can
be started and paused, allowing for them to be used as cumula-
tive timers.
Features
Four front panel variable resistors are used to set the
timers
Connecting Cable No. C4K-CN233 available for external
variable resistors
Indicators show operation and time-up status
Cumulative timer available using pause bits
Timer values may be adjusted without program changes
Specifications
PART NUMBER C200H-TM001
Timing method CR oscillator
No.oftimers 4
Setting ranges 0.1to1.0s,1to10s,10to60s,1to10min
Operation Controllable from PLC program. Usable as accumulating
timer.
External adjustment Via C4K-CN223 (2 m) connector to 20-kresistor
Manual W302
C200HS-INT01
32
SPECIAL I/O MODULES
INTERRUPT INPUT MODULE
The Interrupt Input Module allows real world discrete inputs to
interrupt the scan of the main ladder logic program and execute
specific interrupt ladder logic. For systems requiring immediate
response and fast throughput from field input signals, the Inter-
rupt Input Module can provide fast sub-scan execution and re-
sponse times. The Module can be configured to provide im-
mediate interrupts and scheduled interrupts which repeat
execution on a preset time base. Interrupts can also be confi-
gured to interrupt currently executing interrupt logic.
Features
Using input interrupts, the Interrupt Input Module
temporarily interrupts the main program to execute
interrupt subroutines
High-speed immediate or scheduled logic execution
Provides sub-scan response to field input signals
Ladder instructions control and monitor interrupt inputs
Specifications
PART NUMBER C200HS-INT01
Rated Input Voltage 12 to 24 VDC +10%/--15%
Input Impedance 2K
Input Current 10 mA typical (24 VDC)
ON Voltage 10.2 VDC min.
OFF Voltage 3.0 VDC max.
ON Response Time 0.2 ms max.
OFF Response Time 0.5 ms max.
No. of Circuits 1 (8 points/common)
Internal Current Consumption 20 mA, 5 VDC max.
Weight 200 g max.
Manual W302
Note: The Interrupt Input Module must be mounted on the CPU Rack. Only two
Interrupt Input Modules can be mounted per CPU Rack.
IR 00400
IR 00401
IR 00402
IR 00407
SBN 000
SBN 001
SBN 002
SBN 007
ON Input
The above application shows input bits IR 00400 through IR 00407
assigned to subroutines 00 to 07. For example, when the input for IR
00400 goes ON, normal program execution is interrupted and the
subroutine between SBN 000 and RET is executed. If required, out-
puts can be refreshed immediately by programming the I/O RE-
FRESH instruction within the subroutine.
Circuit Configuration
Interrupt Input Operation
IN
IN
COM
Internal
Circuit
12 to 24 VDC
2k
0.01
µF
Input indicator
1.8
k
The polarity of the input power supply source can be positive or
negative provided that the polarity of each common is the same.
Note: IftheInterruptInputModuleismountedonanExpansionI/ORack,
the interrupt function cannot be used, and the Interrupt Input Mod-
ule will betreated as an ordinary8-point Input Module. Interrupt In-
put Modules cannot be used on Slave Racks.
END(01)
IORF(97)
003
003
SBN(92) 00
RET(93)
Normal
program
area
Interrupt
subroutine
program
area
Only the word 003 output processed in the interrupt
subroutine program is immediately refreshed.
33
SPECIAL I/O MODULES
INTERRUPT INPUT MODULE
C200H-ID215 (DC input)
C200H-ID501 (TTL input)
34
SPECIAL I/O MODULES
HIGH-DENSITY INPUT MODULE
The High-density Input Modules let you pack more input points
into a single I/O slot for greater space savings. Functioning as
as Special I/O modules, they do not use standard I/O points.
Thus, they increase the overall I/O capacity. They provide 32
discrete input points with selectable response times of 2.5 ms or
15 ms. For even shorter signals, 8 inputs can be designated as
quick-response inputs, to receive selectable 1 ms or 4 ms sig-
nals. The modules can also be used with Omron’s Terminal
Blocks, reducing wiring between control panels as well as within
control panels.
Features
8 quick-response inputs available to receive short signals
EasycableconnectiontoOmron’sXW2B-
TerminalBlocks
using XW2Z-
Connecting Cable. Refer to the
Standard
Parts
section for detailed ordering information.
Selectable input response time
LED indicator
Provides a photocoupler for isolation
Specifications
PART NUMBER C200H-ID215 C200H-ID501
MODULE NAME DC INPUT MODULE TTL INPUT MODULE
No. of inputs 32
Input voltage and input current 24 VDC ±10%/--15%
4.1 mA, 24 VDC 5VDC±10%;
3.5mA,5VDC
Operating voltages ON: 14.4 VDC min.
OFF: 5.0 VDC max. ON: 3.0 VDC min.
OFF: 1.0 VDC max.
Output response times ON: 2.5/1.5 ms (selectable)
OFF: 2.5/15 ms (selectable)
Inputs per common 8 pts (4 circuits)
Internal current consumption 130 mA max. (5VDC)
Manual W302
Note: High-densityModulesareequippedwithquick-responsefunctionsandhave
Special I/O functions. When mounting these models to a SYSMAC BUS
Slave, the Remote I/O Master must be the C200H-RM001-PV1 or C200H-
RM201.
35
SPECIAL I/O MODULES
HIGH-DENSITY INPUT MODULE
Circuit Configuration
DC Input: ID215
COM
1000 pF
IN
620
Internal circuits
24 VDC
5.6 k
++
TTL Input: ID501
Connect to either + or -- terminal on DC power supply.
COM
2.4 k
1.1 k
5VDC
IN
Internal circuits
++
The I/O Refresh instruction, IORF(97), can be used with
the quick-response input function to read the input status
held in the quick-response input buffer whenever needed
in a program.
00000
When 00000 is ON, all words from St
to E will be refreshed.
St
E
IORF(97)
St and E would be 101 for Unit #0,
making bits IR 10108 to IR 10115
quick-response input bits.
Machine Number Setting and Input Bit No.
When set to machine No.: n (0 to 9), words [100+10n+1]
can be used as input bits. Input bits 08 to 15 of word 1n1
can be used as quick-response
inputs.
Machine No.
setting
switch
Example: When set to 8,
input bits 18108 to 18115
become quick-response
inputs.
I/O Refresh Instruction
Quick-response Input Operation and Timing
With quick-response input function these High-density I/O
Modules can read short-pulse input signals, such as those from
photomicrosensors.
With standard I/O Modules, an input must be ON during the I/O
refresh period for it to be read into the PLC. Input signals
shorter than the cycle time can be missed, unless they happen
to occur during the I/O refresh.
The quick-response input buffer (on our High-density and
Mixed I/O Module) is used to hold input signals as short as
1 ms or 4 ms (selectable) allowing them to be read into the IR
area during the next I/O refresh. (Any pulse that is equal to or
longer than the minimum time setting affects the program during
the
next
program execution.)
The quick-response input function is available on input points
number 08 to 15 on CN2.
C200H-OD215
(32 transistor output pts.)
C200H-OD501
(32 TTL output pts.)
36
SPECIAL I/O MODULES
HIGH-DENSITY OUTPUT MODULE
The High-density Output Modules let you pack more output
points into a single I/O slot for greater space savings. Treated
as Special I/O modules, they do not use standard I/O points.
Thus, they increase the overall I/O capacity. In static high-densi-
ty mode, they provide 32 discrete output points. In this mode,
the modules can also be used with Omron’s Terminal Blocks,
reducing wiring between control panels as well as within control
panels. In dynamic multiplex mode, the modules provide 128
dynamic output points. In this mode they can be used with nu-
meric displays, etc.
Features
Provide 32 outputs per module in static mode
EasycableconnectiontoOmron’sXW2B-
TerminalBlocks
using XW2Z-
Connecting Cable. Refer to the
Standard
Parts
section for detailed ordering information.
Provide interface to numeric displays, etc. in dynamic mode
Specifications
PART NUMBER C200H-OD215 C200H-OD501
MODULE NAME TRANSISTOR OUTPUT TTL OUTPUT
No. of outputs 32
Rated load voltage 5 to 24 VDC +10%/--15% 5VDC±10%;
Max. load current 16 mA at 4.5 V to
100 mA at 26.4 V/pt.
800 mA/8 pts. 3.2 A/32
pts.
35 mA/pt. 280 mA/8 pts.
1.12 A/32 pts.
Outputs per common 8pts
Output response times ON: 0.2 ms max.
OFF: 0.6 ms max. ON: 0.2 ms max.
OFF: 0.3 ms max.
External connection connector
Residual voltage 0.7 V max. 0.4 V max.
Leakage current 0.1 mA max
External power supply 90 mA, 5 to 24 VDC min. 39 mA, 5 VDC min.
Internal power consumption 220 mA max.
Manual W302
Note: When mounting these models to a Slave Rack, the Remote I/I Master must
be the C200H-RM001-PV1 or C200H-RM201.
37
SPECIAL I/O MODULES
HIGH-DENSITY OUTPUT MODULE
With dynamic outputs, data signals DATA0 to DATA15 are
combined with strobe signals STB0 to STB15 to reduce
wiring and greatly increase output capacity. The output
device must be able to receive dynamic signals.
M7F C200HX/HG/HE
Servodriver Servomotor
Position Control Module
C200H-NC111/NC112
Dynamic Output Mode for Digital Displays
Transistor Output: OD215/TTL Output: OD501
Internal circuits
L
Fuse
OUT
V
R1 V
OD501: 4.7 k5VDC
OD215: None 5 to 24 VDC
R3
+
Common
Circuit Configuration
C200H-MD215/MD115
(16 DC input/16 transistor output pts.)
C200H-MD501
(16 TTL input/16 TTL output pts.)
38
SPECIAL I/O MODULES
MIXED I/O MODULE
The high-density/multiplex mixed Input/Output modules let you
pack more I/O points into a single I/O slot for greater space sav-
ings. Treated as Special I/O modules, they do not use standard
I/O points. Thus, they increase the overall I/O capacity.
In static high-density mode, they provide 16 discrete input
points and 16 discrete output points with selectable input
response times of 2.5 ms or 15 ms. For even shorter input
signals, 8 inputs can be designated as quick-response inputs, to
receive selectable 1 ms or 4 ms signals. In this mode, the
modules can also be used with Omron’s Terminal Blocks,
reducing wiring between control panels as well as within control
panels.
In dynamic multiplex input mode, the modules provide 128
dynamic input points. In this mode they can be used with
keyboards, thumbwheel switches, etc.
Features
Provide 16 inputs and 16 outputs per module in static mode;
128 inputs in dynamic mode
EasycableconnectiontoOmron’sXW2B-
TerminalBlocks
using XW2Z-
Connecting Cable. Refer to the
Standard
Parts
section for detailed ordering information.
Selectable input response time
Up to 10 Special I/O modules per PLC
Provide interface to keyboards, thumbwheel switches, etc. in
dynamic mode
Specifications
MODULE NAME TTL INPUT/OUTPUT MODULE DC INPUT/TRANSISTOR OUTPUT MODULE
PART NUMBER C200H-MD501 C200H-MD215 C200H-MD115
Inputs No. of inputs 16 pts
Input voltage and current 5VDC±10%, 3.5 mA (5 VDC) 24 VDC +10%--15%, 4.1 mA
(24 VDC) 12 VDC +10%--15%, 4.1 mA typical
(12 VDC)
Operating voltages ON: 3.0 V min., OFF: 1.0 V max. ON: 14.4 V min., OFF: 5.0 V max. ON: 8.0 V min., OFF: 3.0 V max.
Input response times ON/OFF: 2.5 ms/15 ms (selectable)
Isolations Photocoupler
Inputs per common 8pts
Outputs No. of outputs 16 pts
Rated load voltage 5VDC 5to24VDC 12 VDC
Max. load current 35 mA/pt, 280 mA/8 pts 100 mA/pt, 800 mA/8 pts 100 mA/pt, 800 mA/8 pts
Residual voltage 0.4 V max. 0.7 V max.
Output response times ON: 0.2 ms max., OFF: 0.3 ms max. ON: 0.2 ms max., OFF: 0.6 ms max.
Leakage current 0.1 mA max.
Outputs per common 8pts
Fuse Present (replacement not possible)
External connection Connector
Internal current consumption (5 VDC) 180 mA max.
Manual W302
Note: When mounting any of the above models to a Slave Rack, the Remote I/O Master must be the C200H-RM001-PV1 or C200H-RM201.
MD501/MD215/MD115
Internal circuits
OUT
L
COM
IN
COM
V1
V2
R1
R3R2
Fuse
C
+
++
STB0
(CN1 A1) DC B A
DATA0 (CN2 A1)
DATA1 (CN2 A2)
DATA2 (CN2 A3)
DATA3 (CN2 A4)
Wd 1n0
Wd 1n1
Wd 1n2
Wd 1n7
to
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
ABCD
39
SPECIAL I/O MODULES
MIXED I/O MODULE
Circuit Configuration
Dynamic Input Mode Operation and Timing
With dynamic inputs, data signals DATA0 to DATA15 are com-
bined with strobe signals STB0 to STB15 to reduce wiring and
greatly increase input capacity. For example, when STB0 is ON,
as shown to the right, data would be read from DATA0 to
DATA3, and the status of switches A through D would be re-
flected in bits 00 through 03 of word 1n0, where n is the Special
I/O Module’s unit number.
R1R2R3C V1V2
MD501 4.7 k1.1 k2.4 kNone 5VDC 5VDC
MD215 None 5.6 k620 1000 pF 5to
24 VDC 24 VDC
MD115 None 2.7 k620 1000 pF 5to
24 VDC 12 VDC
C200H-AD001
C200H-AD002
Flow
Pressure
Temperature
Current
Voltage
Analog input
Transducer
C200HX/HG/HE
Analog signals, such as voltages and currents, are received
from various sensors through the maximum of 8 inputs
(AD002) and converted into 12-bit binary data.
External input signal range can be freely set to cope with
diverse needs.
Built-in functions included: the scaling function, mean func-
tion, peak hold function, square-root extraction function, and
more.
System Configuration
40
SPECIAL I/O MODULES
ANALOG INPUT MODULES
Analog Input Modules accept a variety of analog signals from
external devices, including both voltage and current ranges.
Both Modules provide 12-bit resolutions and fast access to the
PLC.
Features
Cost-effective single-slot modules available with 4 or 8
analog inputs
12-bit resolution
Selectable ranges include 1 to 5 V, 0 to 10 V, and 4 to 20 mA
Specifications
PART NUMBER C200H-AD001 C200H-AD002
Input points 4 8
Voltage input 1to5Vor0to10V 1to5V,0to10V,or
--10 to 10 V
Current
input 4to20mA
External
input imped- Voltage
input 1M
min.
i
n
u
t
i
m
e
d
ance Current
input 250
Resolution Voltage 1/4,000 FS
Current
Total preci-
sion 25°C
77.0°F±0.5% FS Voltage: ±0.25% FS
Current: ±0.4% FS
0°to
55°C
(32°to
131°F)
±1.0% FS Voltage: ±0.6% FS
Current: ±0.8% FS
Conversion speed 2.5 ms max./pt
Converted data 12-bit binary 12-bit binary or 4-digit
BCD code (selectable)
Maximum in-
put signals Voltage
input ±15 V max.
u
t
s
i
g
n
a
l
s
Current
input ±30 mA max.
I/O words required 10 (Special I/O area)
External connections Terminal block Connector
Current consumption 550 mA max., 5 VDC 450 mA max., 5 VDC
Weight 450 g max. 290 g max.
Manual W127 W229
C200H-DA001
C200H-DA002
M
Servomotor driver
Inverter
Recorder
Analog output
C200HX/HG/HE
System Configuration
Converts 12-bit binary data into analog signals (voltage or current) for
output to external devices.
Output signal range can be freely set to cope with diverse needs.
Built-in functions such as the output limit, upper- and lower-limit
alarm, and pulse output functions make the C200HX/HG/HE even
more powerful.
41
SPECIAL I/O MODULES
ANALOG OUTPUT MODULES
Analog Output Module provides an interface to a variety of ex-
ternal analog devices that accept voltage and current ranges,
including servo controllers, recorders, and analog gauges.
Features
Cost-effective single-slot module offers two or four analog
outputs
12-bit resolution
Selectable ranges include 1 to 5 V, 0 to 10 V, -10 to +10 V,
and4to20mA
Specifications
PART NUMBER C200H-DA001 C200H-DA002
Output points 2 4
Voltage output 1to5Vor0to10V --10 to 10 V
Current
output 4to20mA
Resolution Voltage 1/4,095 FS 1/8,190 FS
Current 1/4,095 FS
Total preci-
sion 25°C
77.0°F±0.5% FS Voltage: ±0.3% FS
Current: ±0.5% FS
0°to
55°C
(32°to
131°F)
±1.0% FS Voltage: ±0.5% FS
Current: ±1.0% FS
Conversion speed 2.5 ms max./pt
External output imped-
ance 0.5 min.
Maximum
external out-
put current
Voltage
output 15 mA 10 mA
Current
output ---
Allowable
load resis-
tance of ex-
ternal output
Voltage
output ---
Current
output 400 350
Converted data 12-bit binary Voltage code bit + 12-bit
binary
Current code bit + 12-bit
binary
I/O words required 10 (Special I/O area)
External connections Terminal block Connector
Current consumption 650 mA max., 5 VDC 600 mA max., 5 VDC
Weight 450 g max. 320 g max.
Manual W127 W260
C200H-TS001
C200H-TS101
42
SPECIAL I/O MODULES
TEMPERATURE SENSOR MODULES
Monitor up to 4 temperature sensor inputs directly from the PLC
rack. Choose thermocouple inputs (types J and K), or platinum
RTD inputs. Each module offers multiple ranges and a choice of
Fahrenheit or Celsius scaling.
Features
Available for thermocouple types J and K, or platinum RTD
temperature sensors
Selectable number of inputs
Wide range of temperature settings
Specifications
PART NUMBER C200H-TS001 C200H-TS101
TYPE THERMOCOUPLE PLATINUM
RESISTANCE
THERMOMETER
Temperature
sensor Thermocouples: K (CA),
J (IC) (selectable) RTD
(JPt 100 )
Input points 4 points/Unit max. (1, 2, or 4 points can be selected)
Converted data ±(1% FS + 1°C) max.
Total precision 4.8 s max. when 4 points/Unit is set
2.4 s max. when 2 points/Unit is set
1.2 s max. when 1 points/Unit is set
PLC fetch time Conversion cycle + PLC1 cycle time (5 s max.)
Insulation Between points: Uninsulated
Between input terminal and PLC signal: Insulated with a
photocoupler
I/O words required 10 (Special I/O area)
Current
consumption 450 mA max., 5 VDC
Weight 400 g max.
Manual W124
43
SPECIAL I/O MODULES
TEMPERATURE SENSOR MODULES
Temperature Sensor Modules
C200H-TS001/TS002/TS101/TS102
High-density
Output Module
M7F
G79-
C
Connecting
Cable
(1-to-1)
C200HX/HG/HE
A
B
B
+
--
System Configuration
C200H-TS001/TS002
Thermocouple Input C200H-TS101/TS102
Platinum Resistance
Thermometer Input
Input 1
Input 2
Input 3
Input 4
Input 1
Input 2
Input 3
Input 4
B0
B1
B4
B5
B6
B7
B8
B3
A1
A2
A3
A4
A5
A6
A7
A8
B2
R0
A0
+
--
+
--
+
--
+
-- B9
B0
B1
B8
B3
B4
B5
B6
B7
A1
A2
A3
A4
A5
A6
A7
A8
B9
B2
A0
AB
B
AB
B
AB
B
AB
B
Note: A cold junction compensating circuit, whose precision
is adjusted together with the Module, is provided be-
tween the B4 and B5 terminals of the C200H-TS001
(for thermocouple).
External Connections
Temperature Ranges
C200H-TS001
00 01 02 05 06 07 08 03 04 09 10 11 12 13 14
1,600
1,000
800
600
500
0
50
80
100
150
200
300
400
Unit
Measure-
ment
ranges
Temp, spec code
(2-digit BCD)
Measuring
element Thermocouple
K (CA) Chromel/Alumel J (IC) Iron/Constantan
°C
15 16 17 18 21 22 23 19 20 24 25
500
400
300
--50
--20
0
50
80
100
150
200
Unit
Measure-
ment
ranges
Temp, spec code
(2-digit BCD)
Measuring
element Platinum Resistance thermometer
Pt 100
°F°C°C°F
C200H-TS101
Note: Use the IR bit for setting the temperature range. (Common settings for 4 inputs.)
C200H-TC00
C200H-TC10
C200H-DSC01
Data Setting
Console
44
SPECIAL I/O MODULES
TEMPERATURE CONTROL MODULES
Omron puts accurate temperature control right in the rack to
make advanced PID control with auto-tuning readily accessible.
Eliminates a need for stand-alone controllers with networks.
Display and set parameters with the C200H-DSC01 Data Set-
ting Console. Details on the Data Setting Console are provided
later in this section.
Features
Auto-tuning of PID constants
The temperature controller accepts inputs from a
thermocouple or platinum resistance thermometer. The
module is switch-selectable offering ten different sensor
types.
Transistor, voltage, or current output can be selected as the
control output.
High speed and high accuracy temperature control is
performed with a sampling period of 500 ms and with an
indication accuracy of ±0.5%.
Eight data values such as main set value, alarm set value,
and input shift range can be preset in one data bank and a
maximum of eight data banks can be preset with each bank
preset for a different purpose. It is possible to change the
banks during operation.
Alarm outputs can be selected out of ten modes, such as an
upper limit, lower limit, and upper/lower limit.
The heater current is monitored by the high-precision current
transformer (CT) capable of detecting in 0.1 A units. Through
the use of heater burnout detection, heater burnout can be
quickly detected.
Data input and process value monitoring -- using the Data
Setting Console.
Specifications
PART NUMBER C200H-TC00
C200H-TC10
Current transformer detection current 0.1 to 49.9 A (with a heater burnout detecting current difference of 2.5 A min.), indication accuracy: ±0.5% FS, ±1 digit max.
Input points (no. of loops) Two points (two loops, each of which consists of a temperature sensor and CT)
Temperature control mode PID, ON/OFF (selectable with a switch on the rear panel) (advanced PID with auto-tuning)
Preset memory bank items (8 max.) Main set value, alarm set value, input shift range, proportional band, integral time, derivative time, sensitivity adjustment, etc.
Setting/Indication accuracy ±0.5% of set (designated) value or ±2°C whichever larger, ±1
digit max. ±0.5% of set (designated) value or ±1°C whichever larger, ±1
digit max.
Proportional band 0.0°to 999.9°C/°F (in units of 0.1°C/°F)
Integral (reset) time 0 to 9,999 s (in units of 1 s)
Derivative (rate) time 0 to 9,999 s (in units of 1 s)
Control period 1to99s(inunitsof1s)
Sampling period 500 ms
Input shift range --99.9°to 999.9°C/°F (in units of 0.1°C/°F)
Alarm output mode Selectable from no alarm function, upper alarm, lower alarm, upper/lower alarm, upper-/lower-range alarm, upper/lower alarm
with standby sequence, upper alarm with standby sequence, lower alarm with standby sequence, absolute-value upper alarm,
or absolute-value lower alarm.
No. of banks 8 banks
Internal current consumption 5 VDC, 0.33 A max. (supplied from the Backplane)
External supply voltage 24 VDC +10%/--15%, 200 mA min.
Weight 360 g max.
Manual W225
System Configuration
Temperature Control
Module
Temperature
sensor
CT
Temperature
sensor
CT
Loop 1
Loop 2
C200H-DSC01
Data Setting
Console
Relay box
for heater
control
C200HX/HG/HE
45
SPECIAL I/O MODULES
TEMPERATURE CONTROL MODULES
CONTROL OUTPUT SENSOR PART NUMBER
Transistor output Thermocouple: R, S, K(CA), J(IC),
T
(
C
C
)
E
(
C
R
C
)
B
N
L
(
I
C
)
U
(
C
C
)
C200H-TC001
Voltage output
T
h
e
r
m
o
c
o
u
l
e
:
R
,
S
,
K
(
C
A
)
,
J
(
I
C
)
,
T(CC), E(CRC), B, N, L(IC), U(CC) C200H-TC002
Current output C200H-TC003
Transistor output Platinum resistance thermometer:
J
P
t
1
0
0
P
t
1
0
0
C200H-TC101
Voltage output
P
a
t
i
n
u
m
r
e
s
i
s
t
a
n
c
e
t
h
e
r
m
o
m
e
t
e
r
:
JPt100, Pt100 C200H-TC102
Current output C200H-TC103
C200H-TV00
C200H-TV10
C200H-DSC01
Data Setting Console
46
SPECIAL I/O MODULES
HEAT/COOL TEMPERATURE CONTROL MODULES
Omron puts accurate heat/cool control right in the rack to make
advanced PID control with auto-tuning directly accessible on the
PLC rack. For applications requiring tight process control, such
as plastic extruders. Display and set parameters with the
C200H-DSC01 Data Setting Console.
Features
For stable temperature control, use advanced PID and an
auto-tuning feature. ON/OFF control can also be selected.
Dedicated Module available for each Temperature Sensor.
Two types of Temperature Control Module are available,
depending on the thermocouple or platinum resistance
thermometer temperature sensor used.
Comprehensive output specifications -- three types are
available: C200H-TV

1 for transistor output,
C200H-TV

2 for voltage output, and C200H-TV

3for
current output.
Two Heat/Cool Control loops with a single module
Heater burnout can be quickly detected -- a minimum current
difference of 2.5 A and a heater burnout detection setting
range of 0.1 to 49.9 A allows for the rapid correction.
Eight banks of data settings, such as set point (SP) and
alarm set values, can be preset in eight data banks for easy
selection.
Data Input and Display -- The C200H-DSC01 Data Setting
Console (sold separately) is used to input data and display
process values (PV) and set values (SV). The easy-to-read
display can be panel-mounted.
Data reading/writing User Program of the C200HX/HG/HE
allows reading or writing of various data.
Specifications
PART NUMBER C200H-TV00
C200H-TV10
Current transformer detection
current 0.1 to 49.9 A (with a heater burnout detecting current difference of 2.5 A min.), indication accuracy: ±0.5% FS, ±1 digit max.
Input points (no. of loops) Two points (two loops, each of which consists of a temperature sensor and CT)
Temperature control mode PID, ON/OFF (selectable with a switch on the rear panel) (advanced PID with auto-tuning)
No. of banks 8 banks
Setting/Indication accuracy (see
note) ±0.5% of set (designated) value or ±2°C whichever larger, ±1
digit max. ±0.5% of set (designated) value or ±1°C whichever larger, ±1
digit max.
Hysteresis 0.0°to 999.9°C/°F (in units of 0.1°C/°F)
Proportional band 0.0°to 999.9°C/°F (in units of 0.1°C/°F)
Integral (reset) time 0 to 9,999 s (in units of 1 s)
Derivative (rate) time 0 to 9,999 s (in units of 1 s)
Control period 1to99s(inunitsof1s)
Sampling period 500 ms
Input shift range --99.9°to 999.9°C/°F (in units of 0.1°C/°F)
Internal current consumption 5 VDC, 0.33 A max. (supplied from the Backplane)
External supply voltage 24 VDC +10%/--15%, 200 mA min.
Weight 360 g max.
Manual W240
Note: Theindication accuracyofthermocouplesRandS atatemperatureof200°Cmax.,that of thermocouples K andTata temperature of --100°Cmax., andthatofthermo-
couple U are all ±4°C, ±1 digit max. The indication accuracy of thermocouple B at temperature of 400°C or below is not guaranteed.
Heat/Cool
Temperature
Control Module
Temperature
sensor
CT
Temperature
sensor
CT
Loop 1
Loop 2
C200H-DSC01
Data Setting
Console
Relay box
for heater
and coolant
control
C200HX/HG/HE
System Configuration
47
SPECIAL I/O MODULES
HEAT/COOL TEMPERATURE CONTROL MODULES
CONTROL OUTPUT SENSOR PART NUMBER
Transistor output Thermocouple: R, S, K,
J
T
E
B
N
L
U
C200H-TV001
Voltage output
T
h
e
r
m
o
c
o
u
l
e
:
R
,
S
,
K
,
J, T, E, B, N, L, U C200H-TV002
Current output C200H-TV003
Transistor output Platinum resistance
t
h
t
J
P
t
1
0
0
C200H-TV101
Voltage output
P
a
t
i
n
u
m
r
e
s
i
s
t
a
n
c
e
thermometer: JPt100,
P
1
0
0
C200H-TV102
Current output
P
1
0
0
C200H-TV103
C200H-DSC01
Data Setting Console
C200H-PID0
48
SPECIAL I/O MODULES
PID CONTROL MODULES
This module provides two independent PID loops for process
control right on the PLC rack. Based on Omron’s E5EX-LA
process controller, the C200H-PID0
accepts both current and
voltage analog inputs for pressure, flow and other measure-
ments. The module can be programmed and controlled from the
PLC or from the optional Data Setting Console. (Details on the
Data Setting console are found later in this section.)
Features
Advanced PID -- stable PID control using advanced PID and
an auto-tuning feature. ON/OFF control can also be selected.
High-speed sampling period of 100 ms -- a sampling period of
100 ms is achieved with two loops, enabling high-speed PID
control.
Input noise reduction with digital filter -- mitigation of sudden
input fluctuations makes the PID Control Module effective in
quick-response systems.
Three types of output specification versions are available:
C200H-PID01 for transistor output, C200H-PID02 for voltage
output, and C200H-PID03 for current output.
Eight banks of data settings -- eight data values, including set
point (SP) and alarm set values, can be preset in eight data
banks for easy selection.
Data input and display using Data Setting Console to input
data and display process values (PV) and set values (SV).
Easy-to-read display can be panel-mounted.
Data reading/writing -- the user program of the
C200HX/HG/HE allows reading or writing of various data.
Specifications
PART NUMBER C200H-PID0
Input signal range 4to20mA,1to5V,0to5V,0to10V
Input points (no. of loops) Two points (two loops, each of which consists of a voltage and a current)
Control mode PID, ON/OFF (selectable with a switch on the rear panel) (advanced PID control with auto-tuning)
No. of banks 8 banks
Setting/Indication accuracy ±0.5% FS ±1 digit max. The SV and displayed value match. There is no relative error.
Hysteresis 0.0 to 100.0% FS (in units of 0.1% FS)
Proportional band 0.0 to 999.9 (in units of 0.1)
Integral (reset) time 0 to 9,999 s (in units of 1 s)
Derivative (rate) time 0 to 9,999 s (in units of 1 s)
Control period 1to99s(inunitsof1s)
Sampling period 100 ms
Input shift range --999 to 9,999 (decimal point position is designated by a parameter setting)
Internal current consumption 5 VDC, 0.33 A max. (supplied from the Backplane)
External supply voltage 24 VDC +10%/--15%, 200 mA min.
Weight 360 g max.
Manual W241
PID Control Module
Flow sensor
CT
Flow sensor
CT
Loop 1
Loop 2
C200H-DSC01
Data Setting
Console
Relay box for
valve control
C200HX/HG/HE
System Configuration
49
SPECIAL I/O MODULES
PID CONTROL MODULE
OUTPUT PART NUMBER
Transistor output (open collector) C200H-PID01
Voltage output C200H-PID02
Current output C200H-PID03
C200H-DSC01
50
SPECIAL I/O MODULES
DATA SETTING CONSOLE
The C200H-DSC01 Data Setting Console mounts on the front
panel to display data and provide operator interface for a rack-
mounted Temperature Controller Module, Cam Positioner Mod-
ule and PID Modules. You will need one Data Setting Console
to monitor each Module. Included with the C200H-DSC01 are
mounting brackets, panel decals for modules to identify the
modules and a temperature unit label.
Features
Fits 1/8 DIN cutouts
2 m or 4 m cable
Change set values, parameters
Monitor present value, set value and memory bank number
as well as output status
Specifications
PART NUMBER C200H-DSC01
Size 1/8 DIN (48 x 96 mm)
Applicable
modules C200H-TC

C200H-TV

C200H-PID

C200H-CP114
Display data Set value, present value, bank number, auto-tuning, heater burnout
alarm, mode, bank, step, cam number, ON/OFF, run, alarm 1 and 2
Connecting
cables 2 m: C200H-CN225
4 m: C200H-CN425
Enclosure
rating IP20 (For NEMA 4 rating, use a Y29-49N cover.)
C200H-FZ001
51
SPECIAL I/O MODULE
FUZZY LOGIC MODULE
The Fuzzy Coprocessor Module allows state-of-the-art fuzzy
logic inference processing to be closely integrated with Omron’s
C200HαPLCs. In addition to normal ladder logic control, the
PLC CPU enables pre-processing and post-processing of fuzzy
I/O, which is provided by standard Analog I/O Modules, and/or
internal registers in the PLC CPU, using intelligent I/O READ
and WRITE instructions in ladder logic.
Fuzzy control is best applied to applications that rely heavily on
human control and input such as control for overhead cranes,
flow control, and temperature control.
Features
Up to 8 inputs, 4 outputs
Up to 128 rules
User-definable membership functions
PLC provides pre-processing and post-processing of fuzzy
I/O
The C200HX/HG/HE can handle jobs that used to require
highly-experienced operators.
Specifications
PART NUMBER C200H-FZ001
Fuzzy logic I/O capacity 8 inputs and 4 outputs
F
u
z
z
y
l
o
g
i
c
processor Rule format 8 condition and 2 conclusion parts max.
Rule capacity 128 rules max.
Logic process Forward logic
Logic rule MAX--MIN logical product
Number of labels 7max.
Final calculation Each output can be set independently for calculation by center of gravity, leftmost maximum, or rightmost
maximum method.
Rule with no grade Can be set to retain the previous value or take a preset value.
Membership
functions Condition Defined by up to 4 end points. Grade (height) at the end points must be either 0 or 1 (0 or 4095). Resolution is
4095 by 4095.
f
u
n
c
t
i
o
n
s
Conclusion Only the horizontal position is set. Height is fixed at 4095. Resolution is 4095 by 4095.
I/O words Inputs 8 words max. Each input is allocated one word.12 bits of the word are used, so the range is 000 to FFF (0 to
4095 decimal).
Outputs 4 words max. Each output is allocated one word.12 bits of the word are used, so the range is 000 to FFF (0 to
4095 decimal).
Peripheral device
i
t
i
Communications Half duplex
P
r
i
h
e
r
a
l
d
e
v
i
c
e
communications Synchronization Start-stop synchronization
Baud rate 300, 600, 1200, 2400, 4800, 9600, or 19200 (set on DIP switch 2)
Transmission distance 15 m max.
Interface RS-232C port
Communications protocol Special procedure (1:N)
Processing time 6 ms max. for Unit, 3 to 4 times the cycle time for system.
Self-diagnostics Program check A “memory error” will be generated if an error occurs during the program check.
Data retained in a power interruption Rules and membership functions are retained.
Internal current consumption 5 VDC, 0.3 A max. (Supplied from the Backplane.)
Weight 400 g max.
Manual W208
Analog Output Module
Analog Input Module
Fuzzy Logic Module
Analog inputs
Analog outputs RS-232C cable
(to 9-pin connector)
C200HX/HG/HE
IBM PC/AT or compatible
Fuzzy Support
Software
C500-SU981-E
To 25-pin connector
52
SPECIAL I/O MODULES
FUZZY LOGIC MODULE
System Configuration
C200H-MC221
53
SPECIAL I/O MODULES
DUAL-AXIS MOTION CONTROL MODULE
The dual-axis motion controllers are compatible with servo
drivers that accept analog inputs for a complete motion control
system. Programs are stored internally in the module and can
be selected and monitored from the extensive memory interface
available in the PLC.
The Motion Control Support Software (MCSS) provides the pro-
gram editing, downloading, diagnostic, and on-line monitoring
capability to reduce engineering, debugging, and start-up time.
(Order separately.)
Features
Dual-axis semi-closed loop servo control for simple servo
positioning applications
Internal program storage for fast selection and execution
of motion profiles
Extensive control and monitoring interface reduces
maintenance and debugging
G Code Programming Language subset reduces program
development time
A maximum of 100 programs can be registered
A maximum of eight modules can be mounted to a single
C200HX/HG/HE PLC to control a maximum of 16 axes.
MC Program Edit Menu
MC Parameter Edit Menu
The functions of the MC Module are set with the MC
Support Software.
The MC Support Software has well-constructed menu
functions, making it possible to use the MC Module easily.
The function groups of the MC Module are classified with
the system setup menu and the itemized functions of the
MC Module are classified with the main menus.
These are the main menus of the MC Support Software:
MC Program Edit Menu
MC Parameter Edit Menu
Position Data Edit Menu
MC Monitoring Menu
Write Sophisticated Programs Easily --
with G-language Programming and MC Support Software.
54
SPECIAL I/O MODULES
MOTION CONTROL MODULE
Specifications
PART NUMBER C200H-MC221
Number of I/O words 20 (2 slots)
External connecting devices IBM PC/AT or compatible, Teaching Box, and MPG (manual pulse generator)
Controlled driver Servodrivers that can handle analog inputs
Control Control method Semi-closed loop using incremental encoder (speed command voltage output)
C
o
n
t
r
o
l
Number of controlled axes 2 axes max.
Number of simultaneously con-
trolled axes 2 axes max.
PTP (independent) control Execution by independent programs, operation modes for each axis
Positioning Linear interpolation 2 axes max.
P
s
i
t
i
o
n
i
n
g
Circular interpolation 2axesmax.onaplane
Interrupt inching Inching on an axis with interrupt input to the axis.
Speed control Speed control of up to 2 axes. From 1 to 1,000,000 ppc in single-pulse increments (after quadruplication), if
pulses are used as the unit of control.
Control unit Minimum unit settings 1, 0.1, 0.01, 0.001, 0.0001 (the unit conversion function is not available.)
C
o
n
t
r
o
l
u
n
i
t
Units mm, inch, degree, pulse
Max. command value --39,999,999 to +39,999,999
Acceleration//Deceleration curve Trapezoid or S curve
Acceleration/Deceleration time 0 to 9,998 ms in 2-ms units can be set independently for acceleration and deceleration.
Feed operations Rapid feed speed Example: 36.86 m/min. Conditions
Encoder resolution: 2,048 p/r
Interpolation feed speed Example: 36.86 m/min.
E
c
o
d
e
r
r
e
s
o
l
u
t
i
o
n
:
2
,
0
4
8
/
r
Motor speed: 4,500 r/m
Control unit: 0.001 mm/pulse
Rapid feed override 0 to 100% Setting unit: 0.1%
Interpolation feed override 0 to 199%
S
t
t
i
n
g
u
n
i
t
:
0
.
1
%
Jog feed override 0 to 100%
Task program
t
Number of tasks 2 max. (program execution units)
T
a
s
k
r
o
g
r
a
m
management Number of programs The maximum number of programs differs according to the number of tasks (e.g., 100 programs are con-
trolled if 1 task is used and 50 programs are controlled if 2 tasks are used).
Task program
management Program capacity The maximum number of program blocks varies with the number of tasks (e.g., 800 program blocks are
controlled if 1 tasks is used and 400 program blocks are controlled if 2 tasks are used).
m
a
n
a
g
e
m
e
n
t
Position data capacity 2,000 max. when only 1 axis is used.
Number of registers 32 (mainly used to specify position data numbers)
Sub-program nesting 5 levels max.
Auxiliary function M code 0 to 999
Internal current consumption 0.65 A (0.85 A with Teaching Box connected) at 5 VDC
0.2 A at 24 VDC
Weight 500 g max.
Manual W314, W315, W256
Servomotor
Analog Input
Servodriver
Manual Pulse
Generator
(MPG)
C200HX/HG/HE/HS/S PLC
C200H-MC221
MC Module
Terminal Block
Conversion Unit
External input (dedicated cable) Teaching
Console
MC Support Software (IBM
PC/AT or compatible)
2 Axes
CCW limit input
CW limit input
Origin proximity input
Emergency stop input
2 general-
purpose
inputs
55
SPECIAL I/O MODULES
MOTION CONTROL MODULE
System Configuration
C200H-NC211
C200H-NC112
56
SPECIAL I/O MODULES
POSITION CONTROL MODULE
Position control modules provide either a step and direction
pulse train or CW/CCW pulse trains to control a single- or dual-
axis stepper or servo motor driver. Interface signals include CW
and CCW limits, origin approach, origin stop, emergency stop,
and interrupt signals. Automatic backlash and origin offset func-
tions are now included for precise positioning requirements.
Move parameters can be set up in either ladder logic, or by con-
necting the hand-held programming console and are stored in
battery-backed memory. Extensive diagnostics are also avail-
able to the PLC for quick error detection and troubleshooting.
Features
Pulse output for stepper motor or servo motor driver
Origin and backlash compensation for precision positioning
Teach mode or storage of calculated movement parameters
Internal diagnostics
External signal interface for CW, CCW, origin, emergency
stop, mode, and interrupt
Parameters, speeds, and positions set in CPU DM area
Linear interpolation capability on C200H-NC211
Additional Functions -- C200H-NC211 Only
Simultaneous two-axis control is possible with single-axis
independent control and two-axis linear interpolation.
Position data or speed data can be changed or transferred
from the PLC to the NC211 while the positioning operation is
stopped.
Speed can be changed using the speed coefficient, even
during positioning operation.
Up to 53 positions can be set on both axes.
Specifications
PART NUMBERS C200H-NC211 C200H-NC112
Axes controlled 2 axes/Module 1 axes/Module
Control system Automatic trapezoidal acceleration/deceleration
Position Data --8,388,607 to 8,388,606 pulses
Data capacity 53/axis 20
Speed Data 1 to 250,000 pps
Data capacity 15
Speed adjustment rate 2 to 2,000 pps/1 ms
Origin search Origin proximity None/NO/NC
When provided, H/L level selection is available.
Origin signal Rise or fall selection
Origin compensation 0to±9,999 pulses
Origin search speed High speed, proximity speed setting available
Backlash compensation 0 to 9,999 pulses
Manual operation High-speed jog, low-speed jog, inching
I/O words required 20 (Special I/O area) 10 (Special I/O area)
Internal current consumption 5VDC,0.5Amax. 5 VDC, 0.2 A max.
Weight 500 g max. 400 g max.
Manual W166 W128
57
SPECIAL I/O MODULES
POSITION CONTROL MODULE
Connection Example -- Servo Motor for the Pulse-train Input
C200H-NC211
Position Control Module
C200HX/HG/HE
AC Servo
Driver
Input
Module
XW2Z-

J-A2
Connecting Cable
for the C200H-
NC211
XW2B-40J6-2 Connector/Terminal
Conversion Unit for the C200H-
NC211
AC Servo Driver
AC
Servomotor AC Servomotor
C200H-CT021
C200H-CT001-V1
C200H-CT002
58
SPECIAL I/O MODULES
HIGH-SPEED COUNTER MODULE
The high-speed counter modules provide an interface for ap-
plications where the counting speed exceeds the PLC’s proces-
sing speed. Typical applications include frequency inputs, rotary
encoder interface, position control, cut to length, and motion
control. Built-in I/O and front panel indicators on the module
allow for faster throughput and easy visual monitoring of module
status. Interface signals include count inputs, integral outputs,
and external resets.
Features
Two counters count input signals at a high speed of 75 kcps
max. (C200H-CT021) from Incremental Rotary Encoders or
other sources.
Seven counting modes for varied applications:
Simple counter mode counts input pulses (available with
the C200H-CT021 only)
Drum operations linear mode, circular mode
Preset counter operations -- preset mode
Counting operations -- gate mode (normal and
cumulative), latch mode, sampling mode
Three input modes available: differential phases, up/down
inputs, pulse and direction inputs
Provided with multiplication function (x2/x4) for differential
phase input
Count values can be set in either BCD or HEX
Note: A maximum of 16 C200H-CT021 Modules can be
mounted to a single C200HX-CPU5
-E, C200HX-
CPU6
-E, C200HG-CPU5
-E, or C200HG-CPU6
-E
CPU.
Rotary Encoder (E6A, etc)
Sensor input switch, etc.
C200HX/HG/HE
C200H-CT0

High-speed Counter Module
59
SPECIAL I/O MODULES
HIGH-SPEED COUNTER MODULE
Specifications
PART NUMBER C200H-CT001-V1 C200H-CT002 C200H-CT021
Number of axes 1 axis/Module 2 axes/Module
Operating modes 6 7
Count input Input signal Encoder inputs A, B Counter 1 inputs A, B
Counter 2 inputs A, B
Signal level 5, 12, or 24 VDC (selected
when wiring) RS-422 line driver
(Am26LS31-compatible) 12 or 24 VDC (selected when wiring)
RS-422 line driver (Am26LS31-compatible)
Input modes Differential, up/down, pulse and direction
Counting speed
(see note) 50 kcps 75 kcps
Other Input multiplier (x2 or x4) available for differential inputs
External input Input signal Counter input Z Counter 1: input Z
Counter 2: input Z
Signal level External control inputs IN1 and IN2 Counter 1:
external control inputs IN1 and IN2
Counter 2:
external control inputs IN1 and IN2
5, 12, or 24 VDC (selected
when wiring) RS-422 line driver
(Am26LS31-compatible) 12 or 24 VDC (selected when wiring)
RS-422 line driver (Am26LS31-compatible)
Input signal Control inputs IN1, IN2
Signal level 5, 12, or 24 VDC (selected when wiring) 12 or 24 VDC (selected when wiring)
External output Output External outputs 0 to 7 (8 points)
Output level External output power supply: 5 to 24 VDC
Switching capacity: 16 to 80 mA
I/O words required 10 (Special I/O area)
Internal current consumption 5 VDC, 0.3 A max. 5 VDC, 0.4 A max.
Weight 400 g max. 305 g max.
Manuals W141 W141 W311
Note: Affected by the differential phase pulse input.
System Configuration
A High-speed Counter Module counts input signals from
incremental rotary encoders or other sources.
C200H-CP114 C200H-DSC01
Data Setting Console
60
SPECIAL I/O MODULES
CAM POSITIONER MODULE
The Cam Positioner Module simulates a rotating mechanical
cam, drum sequencer, or programmable limit switch in a PLC
I/O module. The module provides a resolver interface and uses
the Data Setting Console for displaying values.
Features
The cam outputs can be set at 16 external outputs and 32
internal outputs with a total of 48 points. The internal outputs
can be taken directly into the C200HX/HG/HE, reducing
wiring inside the control panel.
The ON/OFF data for the maximum of seven points can be
set for one cam. Data can be registered in one bank. To
facilitate easy set-up changes during operation, a maximum
of eight banks is available for data setting.
The Data Setting Console allows easy monitoring of cam
data settings, present cam angles, or resolver rpm.
To provide an optimum output, use the adjustable operation
function to make fine adjustments of the ON/OFF data.
Data on operating conditions -- such as the present cam
angle, cam outputs for 48 points, resolver rpm, and resolver
status -- can be constantly monitored from the
C200HX/HG/HE side.
Using origin compensation, the machine origin and the
resolver origin can be easily matched.
The resolver rpm can be converted into an actual production
quantity by using the scaling function.
Specifications
PART NUMBER C200H-CP114
Output points 48 points (16 external output points, 32 internal output points)
External outputs NPN transistor open collector (with photo-coupler insulation)
Switching capacity: 100 mA at 24 VDC
Simultaneous ON points: 8 points max.
Resolver cable length 100 m max.
Resolver response rpm 800 rpm max.
Resolver response speed 200 µs (at a sampling frequency of 5 kHz)
Resolver resolution 1°
Program memory EEPROM (8 banks)
Origin compensation 1°or 359°(The present angle needs to be compensated to 0°)
Internal current consumption 5 VDC, 0.3 A max. (Supplied from the Backplane.)
External power supply 24 VDC +10%/--15%,2Amin.
Weight 350 g max.
Manual W224
Cam Positioner Module
C200H-DSC01
Data Setting Console
Solenoid,
DC Input
Module, etc.
3F88L-RS17/17T
3F88L-RS15/15W
Resolver
C200HX/HG/HE
61
SPECIAL I/O MODULES
CAM POSITIONER MODULE
System Configuration
C200H-ASC02
Two RS-232C Ports
Bidirectional serial interface to
Computers
Printers
Bar code readers
PLCs
Other ASCII devices
62
SPECIAL I/O MODULE
ASCII/BASIC MODULE
The ASCII/BASIC Module provides a 24-Kbyte programmable
coprocessor module that operates independently of the PLC.
Two built-in RS-232C ports provide easy interface to a variety of
external devices including other manufacturers’ PLCs, computer
terminals, operator stations, bar code readers, and any other
device utilizing a serial interface. The module is programmable
in either BASIC or Assembly providing a platform for complex
calculations and algorithms at the PLC level. This includes PID,
gas flow calculations and complex math and string manipulation
functions. Communications can be initiated by either the module
or the PLC.
Features
24-Kb, battery-backed RAM and 24-Kb EEPROM
programmable in BASIC or Assembly languages
Special commands to initiate communication with the PLC
Two RS-232C ports, 19,200 baud maximum speed
Built-in clock/calendar including year, month, day, date, hour,
minute, second (accurate to 30 seconds/year)
Specifications
PART NUMBER C200H-ASC02
Baud rate Port 1: 300 to 9,600 bps
Port 2: 300 to 19,200 bps
Transmission distance 15 m max.
Memory capacity BASIC program area:
24K bytes (RAM)
BASIC program storage area: 24K bytes (EEPROM)
Transmission capacity 255 words max. at 20 words per cycle
Diagnostic functions CPU watchdog timer, battery voltage drop
Battery life 5 years at 25°C(77
°F) The life of the battery is shortened if the Module is used at higher temperatures.
I/O words required 10 (Special I/O area)
Internal current consumption 5 VDC, 0.2 A max.
Weight 400 g max.
Manual W165
C200HX/HG/HE
Keyboard Printer
Computer
Port 1 (RS-232C) (RS-232C) Port 1/Port 2
Bar-code reader
NT-series
Programmable
Terminal
(I/O)(Programming)
Modem
ASCII/BASIC Module
63
SPECIAL I/O MODULES
ASCII/BASIC MODULE
System Configuration
C200H-OV001
Input Devices
Computer
Microphone
Tape recorder
Output Devices
Computer
Printer
Speaker
64
SPECIAL I/O MODULES
VOICE MODULE
Use the Voice Module for operator interface messages. Record
up to 60 voice messages on site, or use a tape recorder and
transfer the messages to the module. Messages can also be
uploaded or downloaded through the RS-232C port on the front
panel. The built-in speaker enables immediate message verifi-
cation. Message length and sound quality are selectable.
Microphone jack enables live message broadcast
Flexible message length
Messages can be interrupted to start another message
Messages can be recorded in phrase and word combination
formats
Upload or download messages through the RS-232C port on
the front panel
Specifications
PART NUMBER C200H-OV001
Voice synthesis method Adaptive differential pulse-coded modulation (ADPCM)
Message Recording time 32, 48, or 64 s (switch selectable)
Capacity
(sentences
and phrases)
60 max.
Message input (switch-selectable) MIC IN Microphone input: Unbalanced dynamic microphone (600 )
M
e
s
s
a
g
e
i
n
u
t
(
s
w
i
t
c
h
s
e
l
e
c
t
a
b
l
e
)
LINE IN Tape input: Input impedance: 50 k, unbalanced; Maximum input voltage: 3.3 V
Message output (switch-selectable) SPEAKER
OUT Built-in amplifier output: 0.14 W (8 speaker)
LINE OUT External amplifier output: 600 unbalanced transformer output
Maximum output voltage: 0.5 V rms (effective value)
Both balanced and unbalanced external amplifiers can be connected.
Built-in monitor speaker Diameter 27 mm, 0.1 W (8 )
Input frequency 32-second recordings: 8 kHz
48-second recordings: 5.3 kHz
64-second recordings: 4 kHz
Output frequency characteristics 32-second recordings: 100 Hz to 3.2 kHz
48/64-second recordings: 100 Hz to 2.2 kHz
Low-pass filter (LPF) selector function (see note) Cutoff frequency: 3.2 kHz for 32-second recordings, 2.2 kHz for 48/64-second recordings
Message memory 128K bytes RAM (battery powered)
External communication function
(for saving recorded messages) RS-232C (Baud rate: 19,200/9,600/4,800/2,400 bps. XON/XOFF: yes/no, CTS/RTS: yes/no)
Self-diagnosis function CPU watchdog timer, LOW battery voltage detection
Battery life 5 years at 25°C (battery life is shorter for higher temperatures)
I/O words required 10 (Special I/O area)
Internal current consumption 5VDC,0.3Amax.
Weight 400 g max.
Manual W172
Note: TherecordingtimeoftheVoiceModuleisvariedbychangingtheunit’sinputfrequency.Forimprovedsoundquality,thecutofffrequencyofthelow-passfilterisautomat-
icallychangedtoalowerfrequencywhentherecording timeisincreasedfrom32to either48or64seconds. (Theoutput frequency isset to100 Hzto2.2kHz when the
recording time is set to 48 or 64 seconds.)
Microphone
(dynamic, 600 )
Cassette tape recorder
(50 k, 3.3 V max., audio use)
Voice Input
Voice Module
C200HX/HG/HE
Module’s internal
amplifier output
Speaker
(8 , commercially
available)
LINE OUT
(600 )
External amplifier Speaker
Voice Output
65
SPECIAL I/O MODULES
VOICE MODULE
System Configuration
C200H-IDS01-V1
(electromagnetic, for short distances)
C200H-IDS21
(microwave, for long distances)
66
SPECIAL I/O MODULES
RFID SENSOR MODULE
The RFID Modules provide a direct interface to Omron’s V600
and V620 C200H RFID Sensor Read/Write Heads. The module
acts as the controller for Read/Write Heads that exchange data
with data carriers using RF technology. Applications include
conveyor and pallet storage, product labeling, warehousing ap-
plications, and more. Up to 8 Kb of data can be stored on a
single data carrier. The interface modules provide a quick and
easy interface to the production line PLC using ladder diagram
programming.
Features
Provide flexibility in handling individual workpieces or pallets
by reading product specifications can be read from ID data
carriers (tags)
Allows up-to-date access information on inventory and
material flow
System consists of an ID controller or SYSMAC C200H-IDS
Module, Read/Write (R/W) heads, and data carriers (tags)
Three Read/Write ranges available
Direct monitoring from the C200H-IDS Module with hand-held
programming console
Specifications
PART NUMBER C200H-IDS01-V1 AND C200H-IDS21
Communication control procedure Interactive
Number of R/W Heads (antennas)
connected One per RFID Sensor Module
Data Carrier (DC) 2K-byte SRAM (with replaceable battery), 8K-SRAM (with built-in battery)
256-byte EEPROM
Data Carrier memory format 8-bit format
Commands The following seven commands are used:
Read, Write, Auto Read, Auto Write, Clear-all, Auto Read/Write Abort, and Data Management (C200H-IDS01-V1 only)
Data transferrable per instruction Up to 512 words (1024 bytes) can be transferred at 20 words/scan.
Diagnostic functions CPU watchdog timer
Communication errors -- Data Carrier Missing
Sixcommunicationerrorsidentifythecausesoferrorsthathave occurredduringcommunicationbetweenthe DataCarrier
and the RFID Sensor Module
Error Log
The Error Log function allows communication errors to be displayed in statistical form or in order of occurrence. Error
information is retained by the back-up capacitor.
Monitoring functions The following monitoring functions are available when the RFID Sensor Module is connected to a Hand-held
Programming Console. Use the keyboard sheet provided with the RFID Sensor Module. (Cable length: 4 m max.)
Read (1 byte)
Stepwise Write (1 byte)
Continuous Write
Test
Error Log
Memory backup Error information is backed up by a capacitor for 15 days (at 25°C).
I/O words required 5 (Special I/O area)
Internal current consumption 5 VDC, 0.25 A max.
26 VDC, 0.12 A max. (to drive Read/Write Head or R/W Antenna) See note.
Weight 400 g max.
Manual W153
Note: The Read/Write Head (or Antenna) is supplied 26 VDC. Refer to the
C200H PLC Installation Guides (W111 and W218)
for information on system design.
V600-D

Data Carrier (DC)
V600 Read/Write (R/W)
Head (Antenna)
Data can be read from
or written to a moving DC.
C200H-IDS01-V1
RFID Sensor Module
C200H-PRO27-E
Programming Console
Tests data transmission
and reads out error mes-
sages.
C200HX/HG/HE
C200H-CN422 (4 m)
C200H-CN222 (2 m)
Connecting Cable
Special keysheet for
RFID Sensor Module
Further details on RFID components can be found in Catalog Q80-E3-
.
67
SPECIAL I/O MODULE
RFID SENSOR MODULE
System Configuration
68
COMMUNICATIONS
COMMUNICATIONS 69
Overview 70
Communication Modules 72
Fiber-optic Cable and Connections 89
69
70
COMMUNICATIONS
OVERVIEW
Plant-wide Information Management and
Control Networks
Omron’s advanced plant-wide information management network
capabilities let you harness the power of valuable manufacturing
and production data stored throughout your plant and turn it into
a competitive advantage. Omron’s ethernet connectivity allows
customers to interface PLCs with higher level business
computing systems and other PLCs via Ethernet. To link your
supervisory computers and factory controllers in a seamless,
high-speed, high-capacity network, use Omron’s fiber-optic
based SYSMAC NET communications network. Twin fiber-optic
cables, automatic loopback, and a token ring configuration
provide a reliable, deterministic interface to a variety of
information systems. SYSMAC NET’s fast, 2 Mbps transmission
speed and 2 Kb message size moves large amounts of data
quickly.
Distributed Control Networks
By more tightly integrating their control systems, many
manufacturers have been able to increase productivity and
manufacturing flexibility. Omron’s SYSMAC LINK distributed
control network provides a high speed (2 Mbps) link for
exchanging critical production data between supervisory
computers and programmable controllers in real time.
The token bus peer-to-peer network uses noise resistant
fiber-optic or low cost co-axial cable media for reliable,
deterministic communications. A special data link feature
provides an easy to set up, shared memory system for even
tighter integration between multiple controls and computers.
Operator Interface Terminals on Networks
Omron’s Host Link serial network provides an ideal interface for
today’s data-hungry data acquisition and control software, or
local operator interface. Multiple Operator Interface Terminals
can be connected to a PLC using the Host Link module.
Drivers for this openly available protocol have been developed
for all major third-party operator interface and control software
packages and operator interface devices.
Device-level Networking
Omron offers several options for the networking to factory floor
devices. Omron’s DeviceNet products are compatible with the
DeviceNet specification and provide a variety of distributed I/O
solutions. DeviceNet is an open communications protocol that
allows several vendors’ products to exist on a single network,
giving the customer a wide variety of options to choose from.
Omron’s SYSMAC Bus remote I/O systems significantly lower
wiring and maintenance costs. The SYSMAC Bus remote I/O
connects CPUs and distant I/O using low-cost twisted pair
wiring or fiber-optic cables.
Ethernet
C200H
C2000H
MMI computer
Bridge
MMI computer CV1000
C500 Remote
Rack
Remote
I/O Block
C200H Remote
Rack
C200H Remote
Rack C500 Remote
Rack
SYSMAC BUS Wired System
SYSMAC BUS Fiber-optic System
Fiber-optic
Remote I/O
Block
Line Server
CV1000
CV 500
PLANT INFORMATION SYSTEM
CV/CVM1
MMI computer
SYSMAC LINK
PLANTWIDE INFORMATION
SYSMAC NET
DISTRIBUTED CONTROL
C200HX/HG/HE
Slave
I/O Blocks
Branching
CQM1-DRT21
Trunk line Dedicated
cable
Manifold
Valve Block I/O Control
Station
Device-
Link Cable
RS-232C
Interface Bar Code
Reader
Third-party Products
C200HX/HG/HE
DeviceNet System
Master
C200HX/HG/HE
71
COMMUNICATIONS
OVERVIEW
C200HW-PCU01-E
PC Card Module
Bus Connection Unit
C200HW-CE011
(for 1 Module)
C200HW-CE012
(for 2 Modules)
C200HW-PCS01-E
Ethernet Set
(setup utility driver provided)
Communications Board
C200HW-COM01
C200HW-COM04-E
(with RS-232C port)
72
COMMUNICATIONS MODULES
PC CARD MODULES
Connect to ethernet networks with ease and exchange data files
using PCMCIA cards. The PC Card Module provides two
PCMCIA interface slots. Two type-I or type-II cards or one
type-III PCMCIA card can be installed. Using the C200HW-
PCU01-E, C200Hαmemory contents may be written to memory
cards as files, to exchange production data between PLCs and
PCs. Using the C200HW-PCS01-E with an Ethernet-compatible
PCMCIA card, data may be exchanged using FINS protocol via
UDP/IP.
Features
Data storage and ease of production stage change with Memory
Cards.
A standard SRAM or FLASH card inserted into the slot is
used as file storage
Data can be loaded and saved between the PLC and
memory cards using CMCR (CARD MACRO) instructions
Data written with the PC Card Module to memory cards is
read with the IBM PC/AT or compatible and vice versa
Connects to Office Networks with Ethernet Cards
A standard Ethernet Card can be inserted into the slot and,
using the RS-232C port on the front panel, can be set to
allow connection of the C200HX/HG/HE PLC with the
Ethernet
Data is loaded and saved between the CPU and host
computer by using OMRON’s unique FINS (Factory
Intelligent Network Service) commands. In addition, the PC
Card Module allows the PLC to execute the SEND/RECV
instruction to communicate with the host computer or other
PLCs.
PC Card Module Specifications
PART NUMBER C200HW-PCU01-E
CPU i80386-SX25 MHz
Memory 1 MB DRAM
ROM 512 KB (for BIOS, DOS, and system file storage)
FLASH ROM 1 MB (for BIOS, DOS, and system file storage)
Serial port RS-232C x 1 (for terminal connection setup)
PC card interface PCMCIA 2.1 (3.3-V type is not supported.)
Type

x 2 slots or type

x1slot
Indicators RUN, ERR, PC card access, and PC card formatting
Power supply 5 VDC (supplied by the Power Supply Unit)
Dimensions 34.5 x 130 x 125 (W x H x D)
Weight 400 g max.
Note: I80386 is a registered trademark of Intel Corp. Ethernet is a registered trade-
mark of Xerox, Corp.
73
COMMUNICATIONS MODULES
PC CARD MODULE
System Configuration
Data Storage and Easy Production Stage Changes using Memory Cards
C200HX/HG/HE PC Card Module
Memory card
Communications Board
IBM PC/AT or
compatible
Peripheral
devices
such as
Tempera-
ture Control-
ler, etc.
Connects to OA Networks using Ethernet Cards
Host computer
Ethernet
CV-series PLC
CV500-ETN01 Ethernet Module
C200HX/HG/HE
Ethernet Set and PC Card Module
Production order
data
Production order
data
Recommended Memory Cards
MANUFACTURER PRODUCT
SunDisk compatibles SDP5100A (FLASH PACKER series)
Intel IMC001FLKA (FLASH Card)
Note: OMRON does not guarantee the performance of the above memory cards
although OMRON has confirmed that the above memory cards are suitable
for the PC Card Module.
Recommended Ethernet Cards
MANUFACTURER PRODUCT
Kingston Technology KNE-PCM/T
Others ODI SPEC3 Compatible
74
COMMUNICATIONS MODULES
PC CARD MODULE
Possible Configurations When Installing PC Card Modules
C200HW-CE011
Bus Connection Unit
(for 1 Module)
C200HE-CPU32-E/42-E
C200HG-CPU33-E/43-E/53-E/63-E
C200HX-CPU34-E/44-E/54-E/64-E
CPU
C200HW-COM01/04-E
Communications Board
C200HW-
PCU01--E PC
Card Module
C200HW-PCS01-E
Ethernet Set
C200HW-CE012
Bus Connection Unit
(for 2 Modules)
C200HE-CPU32-E/42-E
C200HG-CPU33-E/43-E/53-E/63-E
C200HX-CPU34-E/44-E/54-E/64-E
CPU
C200HW-COM01/04-E
Communications Board
C200HW-PCU01-E
PC Card Module
C200HW-PCS01-E
Ethernet Set C200HW-
SLK13/23/14/24
SYSMAC LINK
Module
Mounting with the SYSMAC LINK Module
Standard Mounting -- for PC Card Module
C200HS-SNT32
Optional Power Supply Module
C200H-APS01 (for 1 Module
C200H-APS02 (for 2 Modules)
(Optional Power Supply Adapter
required)
Power Supply Connecting Cable
C200H-CN001
(for 1 Module)
C200H-CN002
(for 2 Modules)
Bus Connection Unit
C200HW-CE001
(for 1 Module)
C200HW-CE002
(for 2 Modules)
Communications Board
C200HW-COM01
C200HW-COM04-E
(w/RS-232C port)
75
COMMUNICATIONS MODULES
SYSMAC NET LINK MODULE
SYSMAC NET is a fiber-optic token ring network designed to
transfer large amounts of data between the PLC and IBM PC/AT
Compatible, VME computers, and any ASCII RS-232C devices.
Fiber-optic transmission media provides reliable long distance
communications in harsh environments. Automatic loop-back,
extensive diagnostics, and network utility software provide add-
ed reliability and ease of configuration. The C200HS-SNT32
SYSMAC Module is easily integrated to the C200HαCPU. The
Module connects to the CPU through one of the C200HW-
COM01/COM04-E Communications Boards with a C200HW-
CE001/CE002 Bus Connector.
Features
Achieves high-speed and long-distance communications
through Fiber-optic Cables -- N:N token ring
communications method is available. Transmission is
possible with a node separation of 1 km and a data
transmission rate of 2M bits/s. Transmission up to 3 km is
possible when a long-distance repeater is connected.
Large-scale FA Network configuration -- Up to 126 NSB,
NSU, and SYSMAC NET Link Modules can be connected.
Connect the PLC to a factory computer or host computer
network.
Improved redundancy capabilities -- The automatic
loop-back and node separation test facilitate the taking of
prompt countermeasures when any abnormality occurs.
Easy data links between PLCs -- The built-in application
software allows easy data links between PLCs.
Compatible with H-PCF Fiber-optic Cables -- Possible to
use not only the conventional PCF fiber optic cables but
also H-PCF (hard-clad fiber) Cables. Since solderless
optical connectors can be used, connections on-site have
become easier. (For detailed specifications and ordering
procedures for H-PCF Cables, contact your OMRON
representative.)
Optional Power Supply Module
The SYSMAC Net Module is designed to receive back-up power
supply from the Optional Power Supply Module. Should any
failure of the SYSMAC Net Module occur, the node bypass
function will activate to prevent shutdown of the entire network.
Communication Specifications
ITEM DESCRIPTION
Communications method N:N token ring
Transmission method Manchester code, base band
Data transmission rate 2M bps
Transmission paths 2-conductor fiber optic cable (plastic-clad, crystal
core; core dia.: 200 µm)
Number of nodes 126 max.
Node separation 1kmmax.
Message length 2K bytes max.
Send buffer capacity 1 message
Receive buffer capacity 15 messages
Redundancy functions Automatic loopback
Node bypass
Self-diagnosis function (by test mode function)
Error detection CRC-CCIT
generating function = X16+X12+X5+1
76
COMMUNICATIONS MODULES
SYSMAC NET LINK MODULE
Network Configuration
The SYSMAC NET consists of one line server and a combination of 126 NSB, NSU, and SYSMAC NET Link Modules max.
Central
Power
Supply
IBM PC/AT
or compat-
ible
IBM PC/AT
or compat-
ible
IBM
PC/AT
or
com-
patible
NSB NSB
NSB
Host
computer
RS-232C RS-232C
ASCII
Module C-series
PLC
Line server NSU
Normal loop
Back loop
SYSMAC NETSYSMAC NET Bridge
Power Supply
Adapter
SYSMAC
NET Link
Module
SYSMAC
NET Link
Module
C200HX
/HG/HE C500
C1000H
C2000H
Optical fiber
cable
(2-core)
NSB: Network Service Board
NSU: Network Service Module
Bridge: Used for connecting two networks. Up to 20 bridges can be connected in one network provided that it is treatedas one node.
SYSMACNETLinkModule:Treatedasonenode.(Itdoesn’tfunctionasabridge.WhenusedtogetherwiththeSYSMACLINKModule,
only a total of two Modules can be connected.)
Specifications
PART NUMBER C200HS-SNT32
Transmission direction 1:1 Data send/receive
1:N Data send only (no response)
Broadcasting data transfer:
N:126 max.
Data length 1,000 words max. (2,000 bytes)
Only in the same area
Send/Receive data
to/from PLC The command/response format data for data send or that for
data receive are sent/received if SEND(90) or RECV(98)
has been executed by the program instruction.
Send/Receive data
to/from Module other than
PLC
Command/Response by data send or data receive
Watchdog timer response 1 s (default) or watchdog timer setting value (10 min, 55.35
smax.)
Internal current
consumption 1Amax.
Weight 400 g max.
Manual W114
77
COMMUNICATIONS MODULES
SYSMAC NET LINK MODULE
Possible Configurations When Installing SYSMAC NET Link Modules
The following are the possible configurations for installing a
SYSMAC NET Module on a C200HαCPU Rack.
C200H-APS01
Power Supply Adapter
(for 1 Module) C200HS-SNT32
SYSMAC NET Link Module
C200HW-CE001
Bus Connection Unit (for 1 Module)
C200HE-CPU32-E/42-E
C200HG-CPU33-E/43-E/53-E/63-E
C200HX-CPU34-E/44-E/54-E/64-E
CPU
C200HW-COM01/04-E
Communications Board
One Module Mounted
C200H-APS02
Power Supply Adapter
(for 2 Modules) C200HS-SNT32
SYSMAC NET
Link Module
C200HW-CE002
Bus Connection Unit (for 2 Modules)
C200HE-CPU32-E/42-E
C200HG-CPU33-E/43-E/53-E/63-E
C200HX-CPU34-E/44-E/54-E/64-E
CPU
C200HW-COM01/04-E
Communications Board
Two Modules Mounted
C200H-APS01
Power Supply Adapter
(for 1 Module)
C200HS-SNT32
SYSMAC NET
Link Module
C200HW-CE002
Bus Connection Unit (for 2 Modules)
C200HS-
SLK13/23/14/24
SYSMAC LINK
Module
C200HE-CPU32-E/42-E
C200HG-CPU33-E/43-E/53-E/63-E
C200HX-CPU34-E/44-E/54-E/64-E
CPU
C200HW-COM01/04-E
Communications Board
With SYSMAC LINK Module
Note: UptotwoSYSMACLINKModulesandtheSYSMACNETLinkModulecanbemountedtotheleft
of the CPU.
C200H-APS03
Optional Power Supply Module
Bus Connection Unit
C200HW-CE001
(for 1 Module)
C200HW-CE002
(for 2 Modules)
Communications Board
C200HW-COM01
C200HW-COM04-E
(w/RS-232C port)
C200HW-SLK23/24
(Coaxial cable) C200HW-SLK13/14
(Fiber-optic)
78
COMMUNICATIONS MODULES
SYSMAC LINK MODULES
SYSMAC LINK is a fiber-optic token ring network designed to
transfer large amounts of control data in real-time between
PLCs. Both coaxial and fiber-optic medias may be used.
The C200HαSYSMAC Link Modules are easily integrated to
the C200HαCPU. The Modules connect to the CPU through
one of the C200HW-COM01/COM04-E Communications
Boards with a C200HW-CE001/CE002 Bus Connector.
Features
Maximum of 62 SYSMAC LINK Modules -- Up to 62
SYSMAC LINK Modules can be connected in one network. In
addition, two SYSMAC LINK Modules can be mounted on
one PLC, allowing multi-level system configuration.
Data Modules -- The data link capacity is as large as 2,966
words. High-speed and large-capacity data communications
are possible using the LR area and DM area.
Flexible Data Link configuration -- Since an optimum data link
table can be created for each node (Machine No.) using the
SYSMAC Support or SYSWIN, the data link area can be
used effectively.
Event communications -- using the SEND and RECV
instructions, up to 256 words of data can be sent or received
for any node in the network.
Remote programming or monitoring using the SYSMAC
Support Software -- Programs can be transferred to any
SYSMAC Module within the network and various monitoring
operations can be performed for that Module.
Built-in LSI exclusively for communications -- The built-in LSI
allows setting of the communication time period between
SYSMAC Modules. The control station is automatically
switched when any trouble occurs in the data link control
station, assuring a highly reliable data link system.
Optional Power Supply Module
The SYSMAC Link Modules are designed to receive back-up
power supply from the Optional Power Supply Module. Should
any failure of the SYSMAC Link Module occur, the node bypass
function will activate to prevent shutdown of the entire network.
Note: Mount the SYSMAC LINK Module to the left of the CPU.
The SYSMAC LINK Module cannot be used with the
C200HE-CPU11-E.
79
COMMUNICATIONS MODULES
SYSMAC LINK MODULES
Specifications
PART NUMBER C200HW-SLK23/24 (COAXIAL) C200HW-SLK13/14 (FIBER OPTIC)
Communications method N:N token ring
Transmission method Manchester code, base band
Transmission path Bus Daisy chain
Data transmission rate 2M bps
Transmission media Coaxial cable (5C-2V) Hard-plastic-clad quartz optical fiber
cable
Node separation 1kmmax. 10 km max. (800 m max. between
nodes)
Message length 512 bytes max. (256 words)
Connectors BNC (F Adapter) Full, half-lock press-in connector
Link functions Data link, data read/write service
Data link words C200HW-SLK13/23: 918 words max.
C200HW-SLK14/24: 2,966 words max.
Send buffer capacity 1 message
Receive buffer capacity 2 messages
RAS functions Automatic polling unit backup, self-diagnostics (internode echo tests), failed
node bypass (optical systems only), watchdog timer, error (CRC-CCITT)
detection = X16+X12+X5+1
Current consumption 0.8 A max.
Weight 400 g max. 500 g max.
Manual W174
System Configuration
C200HX/HG/HE CVM1 CV500/CV1000/CV2000
IBM PC/AT or
compatible
SYSMAC LINK Support Board
3G8F5-SLK21-E
Up to 62 nodes separated by a total of 1 km max
C1000H-TER01
Termination Resistance
is necessary
C1000H-TER01
Termination Resistance
is necessary
Coaxial Cable System
80
COMMUNICATIONS MODULES
SYSMAC LINK MODULES
C200HX/HG/HE
CVM1 CV500/CV1000/CV2000
Up to 62 nodes separated by a total of 10 km max.
with 800 m max between nodes
Uninterruptible Power
S
y
stem
(
see note 3
)
C200H-APS03 Backup
Power Supply Module
(see note 1)
C1000H-APS01 Backup
Power Supply Module
IBM PC/AT or
compatible
SYSMAC LINK
Support Board
3G8F5-SLK21-E
Backup Power Supply
(
see note 2
)
Fiber-optic System
Note: 1. TheBackupPowerSupply isprovidedwithPowerSupplyCables(C200H-CN111,C1000H-CN111forone Module). WhensupplyingpowertotwoModulessimulta-
neously, order the C200H-CN211 Cable for one Module.
2. The Backup Power Supply Module for a PLC is different in shape from that for a IBM PC/AT or compatible. Be sure to use an appropriate Power Supply.
3. The Backup Power Supply must be separated from the main power supply line to the PLC.
Possible Configurations When Installing SYSMAC Link Modules
One Module Mounted
C200HW-SLK13/23/14/24
SYSMAC LINK Module
C200HE-CPU32-E/42-E
C200HG-CPU33-E/43-E/53-E/63-E
C200HX-CPU34-E/44-E/54-E/64-E
CPU
C200HW-CE001
Bus Connection Units
(for 1 Module)
C200HW-COM01/04-E
Communications Board
Two Modules Mounted
C200HE-CPU32-E/42-E
C200HG-CPU33-E/43-E/53-E/63-E
C200HX-CPU34-E/44-E/54-E/64-E
CPU
C200HW-CE002
Bus Connection Unit
(for 2 Modules)
C200HW-SLK13/23/14/24
SYSMAC LINK Modules
C200HW-COM01/04-E
Communications Board
C200HW-DRM21
81
COMMUNICATIONS MODULES
DEVICENET SCANNER MODULE
The DeviceNet Scanner Module for the C200Hαallows open
communication over DeviceNet networks with Omron and other
vendors’ I/O products. DeviceNet’s open communications proto-
col allows the greatest flexibility in design of distributed I/O,
while at the same time reducing installation costs.
Features
Dedicated cable saves wiring effort -- two nodes are
connected through a single dedicated cable, greatly
reducing installation costs
Allows T-type bifurcation, branching, and multi-drop wiring.
Connects to 50 slaves max. for 1,600-point I/O control
possible with the C200HX-, C200HG-, and C200HE-series
Master
Network length of 500 meters max. -- possible with a
speed of 125K bps
Communication at 500K bps max. -- possible with a
network length of 100 m max.
Conforms to DeviceNet specifications
DeviceNet Communications Specifications
The communications specifications of the DeviceNet Master Module
conform to the DeviceNet communications protocol.
ITEM SPECIFICATIONS
Baud rate 500K, 250K, or 125K bps (selectable)
Communications
distance Communications
speed (K bps) Max.
network
length (m)
Branch
length (m) Total branch
length (m)
500 100 max. 6max. 39 max.
250 250 max. 78 max.
125 500 max. 156 max.
Error control CRC, node address multiple check, and scan list collation
Cable Dedicated cable
Specifications
PART NUMBER C200HW-DRM21
Available PLC C200HX/HG/HE
Max. No. of
connecting PLCs 1
Mounting position Mounted to the CPU or Expansion I/O Rack. (Cannot be
mounted to the Slave Rack)
Max. no. of I/O
points 1,600
Max. no. of
connecting slaves 50
Manual W267
82
COMMUNICATIONS MODULES
DEVICENET SCANNER MODULE
System Configuration Example
Master
Slave
C200HX/HG/HE
DRT1-1016X
DRT1-0016X
Sensor Terminal
(8 sensor input
points)
Analog Output
Terminal
(2 output points)
Analog Input
Terminal
(4 or 2 input points)
Remote I/O Terminal
(8 or 16 input and
8 or 16 output points)
Remote Adapter
(16 input and 16
output points)
Branching
T-type bifurcation T-type bifurcation
T-type Bifurcation
Tap
I/O Block
CQM1-DRT21
(16 inputs, 16 outputs)
Trunk line
Other companies’ products Dedicated cable
Manifold Valve Block I/O Control Station
DeviceLink Cable
RS-232C Interface Bar Code Reader
T-type Bifurcation Tap
(with termination
resistor)
T-type Bifurcation
Tap
DRT1-HD16s
DRT1-ND16X DRT1-DA02 DRT1-AD04 DRT1-1D08/16
DRT1-OD08/16
SYSMAC CQM1
(800 inputs/800 outputs)
Fiber-optic Master
C200H-RM001-PV1 Wired Master
C200H-RM201
83
COMMUNICATIONS MODULES
REMOTE I/O MASTER MODULES
The SYSMAC BUS Remote I/O system is ideal for distribution
of I/O and other devices at long distances from the CPU. Multi-
ple remote I/O systems can be connected to a single CPU al-
lowing maximum configuration flexibility.
A SYSMAC BUS Remote I/O system consists of a Remote
Master and one or more Remote Slave modules. Both small
and large rack-style I/O can be mixed in the same remote I/O
system. Remote terminal blocks allow for distribution of 8- and
16-point I/O blocks in a wired remote I/O system. Stand-alone
fiber-optic I/O modules allow distribution of 8-point I/O blocks in
a fiber-optic remote I/O system. I/O Link modules allow connec-
tion of a PLC to a fiber-optic remote I/O system. Special link
adapters are available for extended distances and mixing media
types.
Features
High-speed distribution with twisted pair wiring (saving
both wiring efforts and time) or select fiber-optic cable
versions
Variety of I/O styles and types in a given remote I/O
system
RS-485 communications at 187.5 Kbps
Connect C200H I/O, C500 I/O, G7 remote I/O terminals,
programmable terminals
Note: Remote I/O Master Module cannot be used with a DeviceNet Master Module.
Available Remote I/O Slaves
MODULE WORDS
ALLOCATED MAX. IN FIBER-OPTIC SYSTEMS MAX. IN WIRED SYSTEMS
Remote I/O Slave Modules C200H Slave
Racks IR 050 to IR 099 5 (any Expansion I/O Racks connected to Slave Racks must be counted as one additional Slave
each)
C500 Slave
Racks 2 (If C200H and C500 Slave Racks are both used under the same Master, compute the total for
C200H Slaves, counting each C500 Slave as two C200H Slaves.)
Fiber-optic I/O Module IR 200 to IR 231 32 Cannot connect.
Programmable Terminals Cannot connect. 8 (4 words allocated to each) (See
n
o
t
e
)
I/O Terminals 32 (1 word allocated to each)
(
note)
Remote Interfaces 32 (1 word allocated to each)
CQM1 I/O links created to C200H 8 (4 words allocated to each)
Note: When using the above Modules in combination, be careful not to allocate the same words.
84
COMMUNICATIONS MODULES
REMOTE I/O MASTER MODULES
I/O Links to the CQM1
C200HX/HG/HE with
C200H-RM201 Master CQM1 with I/O Link Module
(CQM1-LK501)
Setto#0at IR 200/201 Output IR 001/002 The CQM1 allocates I/O
w
o
r
d
s
a
c
c
o
r
d
i
n
g
t
o
t
h
e
s
l
o
t
t
h
e
S
e
t
t
o
#
0
a
t
the CQM1 IR 202/203 Input IR 100/101 wor
d
s accor
d
i
ng to t
h
es
l
ot t
h
e
I/O Link Module is mounted to.
System Configuration
Wired Remote I/O System
C200H-RM001-PV1
Fiber-optic Remote
I/O Master Module
Slave Rack
C200H-RT001-P/RT002-P
Remote I/O Slave Module
C500 Slave Rack
C500-RT001/002-(P)V1
Remote I/O Slave Module
I/O Link Module
Fiber-optic I/O
Module Repeater
Module Fiber-optic I/O
Module
Terminator
C200H-RM201
Wired Remote I/O
Master Module
Slave Rack
C500 Slave Rack
C500-RT201
Remote I/O Slave Module
G7TC I/O Block
G71 I/O Interface
G72C I/O Terminal
Fiber-
optic
Cable
Twisted-pair
cable
5Slave
Racks max.,
C500 Slave
Rack
counted as 2.
5Slave
Racks max.,
C500 Slave
Rack
counted as 2.
64 Modules (32 words) max.; Repeater
Module not counted and required for
more than 32 Modules.
32 Module
(32 words) max.
C200H-RT201/RT202 Remote
I/O Slave Module
To other Slaves (PTs, I/O Link Modules, etc.)
C200H-BC

1-V2
Backplane C200H-BC

1-V2
Backplane
(Calculate one
C500 Module as
two C200HX/
HG/HE Mod-
ules)
(Maximum of two Modules can be
mounted.) (Maximum of two Modules can be
mounted.)
(Calculate one
C500 Module
as two C200HX/
HG/HE Modules)
Fiber-optic Remote I/O System
C200H-LK101-PV1
Host Link Module
(Fiber-optic)
C200H-LK202-V1
Host Link Module
(RS-422)
C200H-LK201-V1
Host Link Module
(RS-232C)
85
COMMUNICATIONS MODULES
HOST LINK MODULES
Host Link allows any computer or other communications de-
vices to communicate with one (RS-232C), or several (RS-422)
Omron PLCs. Multiple system levels can be connected to the
same PLC with up to 32 PLCs connected to one computer. Om-
ron’s Host Link protocol is well defined and available for custom
software driver development and operator interface connection
to Omron PLCs. Most major operator interface companies have
Host Link interfaces and drivers available. Host Link systems
allow SYSWIN Programming Software or SSS to program and
monitor any PLC in the system.
When configuring a Host Link system:
The computer must have one serial port available
If a fiber-optic, or RS-422 Host Link module is used, Link
Adapters must be included in the system
Features
The Host Link protocol is common to all Omron PLCs, including
the CPM1, CQM1, C200H, C200HS, C200HE, C200HG,
C200HX, C1000H, C2000H, and CV-series PLCs.
Connect up to 32 PLCs to a single host computer
Use twisted pair or fiber-optic transmission media
On the Host Link Module side:
IR area can be read or written
Programs can be uploaded or downloaded
Up to two Host Link Modules can be connected to a CPU
or Expansion I/O Module. RS-232C, RS-422, and
plastic-clad fiber-optic are available
Host Link Modules can be used in combination
(multi-drop) with other C-series Modules
Host Link Modules can be connected to the Operator
Interface Terminal
86
COMMUNICATIONS MODULES
HOST LINK MODULES
System Configuration
Multilevel Host Link System
The following example illustrates the use of the
C200H-LK101-PV1 (fiber-optic) with two personal computers for
system monitoring and data loading.
3G2A9-AL004-PE
Link Adapter Host computer
(IBM PC/AT or
compatible) for
system monitoring
Host computer
(IBM PC/AT or
compatible) for
data management
Two
Host Link
Modules
Host Link Module RS-232C
RS-232C
Fiber-optic Cable
3G2A9-AL004-PE
Link Adapter
Fiber-optic Cable
Fiber-optic Cable
Host Link System with SYSMAC Support Software
or SYSWIN
Various functions, such as offline programming or online
monitoring, can be developed by connecting to the IBM PC/AT
or compatible with the use of SYSMAC Support Software or
SYSWIN.
3G2A9-AL004
Link Adapter
Host computer (IBM PC/
AT or compatible) with the
C500-ZL3AT1-E SYSMAC
Support Software, or
SYSWIN
C200H-LK202-V1
(as an example)
RS-232C
RS-422
C200H-LK401
PC Link Module
87
COMMUNICATIONS MODULES
PC LINK MODULES
PC Link is a peer-to-peer communication system allowing high-
speed transfer of data between PLCs over long distances. Both
small and large rack PLCs can be connected to the same sys-
tem. Standard Link Adapters are available for fiber-optic media
and longer transmission distances. No special programming is
required to transfer data, and multi-level systems can be con-
nected to a single PLC.
Features
High-speed data transfer between up to 32 PLCs
No special programming required
Multi-level capability
Specifications
PART NUMBER C200H-LK401
Communication method 2-conductor, half duplex
Synchronization HDLC
Transmission speed 128K bps
Transmission method Broadcasting
Transmission distance 500 m (total cable length in system without optical links, including branch lines)
Max. no. of PLC Link
M
d
l
S
t
PLC of polling unit Single-level Multilevel
M
a
x
.
n
o
.
o
f
P
L
C
L
i
n
k
Modules per System
(see note) C200HX/HG/HE, C1000H, or
C2000H 32 16
Transmission LR bits No. of PC Link Modules 23to4 5to8 9to16 17 to 32
T
r
a
n
s
m
i
s
s
i
o
n
L
R
b
i
t
s
C200HX/HG/HE,
C1000H, or C2000H 512 256 128 64 32
Transmission time 35 ms max. (for 128 bits with 8 PLC Link Modules)
Diagnostic functions CPU watchdog timer, CRC transmission error check
Interface RS-485
Cable used Shielded twisted pair
Manual W135
Note: Use a 3G2A5-LK009-V1 PLC Link Module when connecting to the C1000H(F) or C2000H.
88
COMMUNICATIONS MODULES
PC LINK MODULES
PC link
PLC
PC link
PLC
PC link
PLC
PC link
PLC
PC link
PLC
PC link
PLC
PC link
PLC
PC link
PLC
PLC link
PC link
PLC
PC link
PLC
PC link
PLC
PC link
PLC
PC link
PC link
PLC
PC link
PLC
PC link
PLC
PC link
PLC
PLC link
PC link
PLC
PC link
PLC
PC link
PLC
PC link
PLC
Use a Link Adapter.
Use RS-232C, RS-422, or fiber-optic
cable depending on application.
PC Link System Hierarchy Multi-level System (4 Levels Max.)
Level 1
Level 2
Level 3
Level 4
Usage of Link Relay Area
PLC #0
LR area
Machine #1
data input area
Own area becomes the write area
(send) for the other machine.
For example, when inputting data
5232 into LR 00 of machine #0, the
data 5232 is output to the LR 00 of
machines #1 to #n.
Write
(Send)
Read
(Receive)
Own LR
Other
machine’s LR Own LR
Other
machine’s LR
Machine #2
data input area
Machine #n
data input area
Own area
PLC #1
LR area
Own area
Machine #2
data input area
Machine #n
data input area
Machine #0
data input area
PLC #2
LR area
Machine #1
data input area
Own area
Machine #n
data input area
Machine #0
data input area
PLC #3
LR area
Machine #1
data input area
Machine #2
data input area
Own area
Machine #0
data input area
Write
(Send)
Read
(Receive)
Application Example
C200HX/HG/HE
CPU Rack
C200HX/HG/HE
Expansion I/O Rack
PC Link -- offering high-speed peer-to-peer
communications between PLCs.
Up to two PC Link Modules can be connected to the
C200HX/HG/HE CPU C200H--LK401or Expansion I/O
Module.
The PC Link Module is included in the connectable
number of Special I/O Modules (10 Modules max.).
Although this requires Machine No. setting, it doesn’t
occupy the IR area or DM area.
Using the split processing of the PC Link Module, PC
Link service can be divided into two, four, or eight
parts, preventing any increase in the cycle time.
89
COMMUNICATIONS
FIBER-OPTIC CABLE AND CONNECTIONS
Omron pioneered the use of fiber-optics for factory floor com-
munications in 1985 by introducing standard fiber-optic inter-
faces for Remote I/O and all Omron industrial communications
networks. Fiber-optic communications offer distinct advantages
over conventional wiring, including electrical noise immunity and
increased transmission distances.
Recent developments in fiber-optic and communications
technology have provided a variety of cost-effective and
easy-to-install solutions. Simple field termination, lower cable
costs and a variety of fiber-optic cable types allow the effective
use of fiber-optic communications in most industrial
applications.
Omron offers a variety of standard direct-connect fiber-optic
modules for fiber-optic communications. Two types of modules
are available: -P suffix types are for use with APF, HPCF and
PCF Cable types. Non -P suffix types are for use with HPCF
and PCF Cable types. Both of these module types accept the
fiber-optic cable directly. No adapter is needed.
All Plastic Fiber (APF)
All Plastic Fiber is ideal for short transmission distances up to 20
meters in remote I/O, or Host Link communications. Field
termination requires no special tools or skills. APF requires the
use of -P modules. The connectors used with APF are the
3G5A2 connectors.
APF
Hard Plastic-clad Fiber (HPCF)
Hard Plastic-clad Fiber has a 200 micron core cable for
maximum distances of up to 200 meters without repeaters. It is
available in both a zipcord style and a reinforced plastic-jacketed
style with stress relief for pulling through conduit. A termination
tool kit is required for field terminations. Bulk cable lengths up to
1 km are available. The connectors used with HPCF are the
S3200 connectors.
HPCF Zipcord
HPCF Reinforced
90
COMMUNICATIONS
FIBER-OPTIC CABLE AND CONNECTIONS
PCF Indoor
PCF Indoor/Outdoor
Plastic-clad Fiber (PCF)
Plastic-clad Fiber is a high performance fiber allowing maximum
distances of up to 800 meters (0.5 mile) without repeaters.
Pre-terminated lengths from 0.1 to 800 meters are available.
Connector bodies can be easily removed for running cable
through ducts, then re-assembled.
All Glass Crystal Fiber (AGF)
Special cable and configurations are available for longer
distance requirements, up to 3 km. The maximum transmission
distance with each type of fiber-optic cable is determined by the
kind of Remote I/O or Host Link modules used. These modules
either have a -P or no -P in the part number. The table below
shows maximum transmission distances. Longer distances are
possible using standard repeaters.
System Compatibility
The following table shows which Fiber-optic Cable can be used
with each system. The table also shows the maximum length of
each Cable.
FIBER-OPTIC CABLE APF HPCF PCF
SYSMAC BUS with -P modules 20 m
(65 ft.) 100 m
(328 ft.) 200 m
(656 ft.)
SYSMAC BUS with non -P modules 200 m
(656 ft.) 800 m
(0.5 mile)
SYSMAC WAY with -P modules
(C-series only) 20 m
(65 ft.) 100 m
(328 ft.) 200 m
(656 ft.)
SYSMAC WAY with non -P modules
(C-series only) 200 m
(656 ft.) 800 m
(0.5 mile)
SYSMAC NET 800 m
(0.5 mile) 1000 m
(0.62 mile)
A Part Number Summary of Fiber-optic
Cable and Connectors
Refer to the Standard Parts section of this catalog for an
inclusive list of Fiber-optic Connectors and Fiber-optic Cable in
three basic types (offering numerous selections within each
type).
PROGRAMMING
PROGRAMMING 91
Programming Software
SSS and SYSWIN 92
Protocol Support Software 94
Programming Peripherals and Cables 97
Programming Instructions 99
91
Overview of Software Options
C200HαCPUs can be programmed using Omron’s SYSWIN
Programming Software. SYSWIN is a Microsoft
Windows-based programming and documentation
application. SYSWIN provides you with an easy and intuitive
graphical user interface designed for use with all of Omron’s
C and CV series PLCs. SYSWIN also offers a
comprehensive range of functions for the PLC programmer,
from program editing to full symbolic and network debugging.
C200HαCPUscanalsobeprogrammedusing
Omron’s SSS DOS programming packages.
92
PROGRAMMING SOFTWARE
SYSWIN OR SSS
System Information
PLCS SUPPORTED CPM1, C**K, C**H, CQM1, C200H, C200HS, C500,
C1000H, C2000H, C200HE, C200HG, C200HX,
CVM1+EV
Communications SYSMAC NET, SYSMAC LINK, HOST LINK
Computer requirements 486DX2/50
RAM Capacity 2 or 4 MB RAM minimum
Free disk space 8Mb of free hard disk space
Floppy disk drive 3.5” double density
Communication port 1 or 2, with RS--232C port or RS--422
Video Color VGA or better
Save time with Easy and Intuitive Programming
SYSWIN provides you with fast and easy programming
operations. With simple point and click editing, creating ladder
logic is a snap. Not sure about which function to use? SYSWIN
provides you with a quick categorization of PLC functions and
extensive on-line help. First time users will find it easy to learn
while working with Omron’s PLCs and Software.
Powerful Editing
Extensive editing features of SYSWIN lets you create and
modify programs quickly and easily. Cut and paste library
functions let you take advantage of your existing code. In
addition, you can easily find and replace program addresses
and documentation throughout your program.
93
PROGRAMMING SOFTWARE
SYSWIN OR SSS
Documentation
Need to document your program? SYSWIN gives you lots of
room for commenting addresses (30 characters), networks, and
blocks of programs (up to 32K per). In addition, managing your
documentation is easy using the Address Symbol Editor. With
the Address Symbol editor you get all of our internal relays
already documented as well as a summary of all addresses
used in the program and documentation. Simply select a new
address for your program and choose from the documentation.
In addition you can sort your documentation by address or
symbol.
Extensive Monitoring Tools
SYSWIN programming software let’s you monitor bit status,
specified I/O status, word content, or Data memory on-line. With
the
Data Display
, monitoring large areas of memory is made
easy. Different areas of memory can be monitored
simultaneously -- as well as in different data formats, such as
hex, decimal, binary, ASCII, and floating point.
Powerful Cross Reference
SYSWIN’s address cross referencer is great tool for debugging
your program. With a simple point and click you can view all
your addresses, location and usage while also viewing ladder
logic. Then simply click on any address and your ladder logic
automatically moves to the location of address.
94
PROGRAMMING SOFTWARE
PROTOCOL SUPPORT SOFTWARE
Overview
The C200HW-COM04-E, C200HW-COM05-E, and
C200HW-COM06-E Communication Boards have a protocol
macro capability. The Protocol Support Software makes it
possible to customize communication sequences by using the
protocol macro. The Protocol Support Software supports seven
types of standard communications sequences -- to either
customize or use as they are.
The conversational-type menu of the Protocol Support
Software allows communication sequences to be
registered easily.
The Protocol Support Software allows a maximum of
1,000 communication sequences to be registered, each
having 16 steps max.
Each of the registered communication sequences can
include data for the transmission method, link word,
monitor period, and response advice method to be used
with the registered communication sequence. X-ON and
X-OFF flow control, RS and CS flow, modem control,
delimiter control and the contention method are supported
by the Protocol Support Software.
Each of the steps can include data for the repetition
number, a communication command, communication
message, reception matrix, the next process to be
executed, and the error processing command to be
executed if the step has an execution error.
Any destination address or communications data set with
the Protocol Support Software can include variable N,
wildcard, and word call settings. Whenever a step is
repeated, the value of variable N in the step will increase
by one. Because of this, a message can be transmitted to
more than one address continuously, or the table data
stored in any word can be transmitted continuously.
The Protocol Support Software automatically allows
transmission of any communication message with an error
check code, such as SUN, LRC, or CRC, and data for the
length of the communication message. At the destination
address of the communication message, the Protocol
Support Software allows the checking of the
communication message according to the error check
code and the data for the length of the communication
message so the destination address can receive the
communication message correctly.
The process can be defined with an END, GOTO, NEXT, or
ABORT that is executed right after each step is executed
with or without any error.
A maximum of 15 types of expected reception messages
can be set with a reception matrix. Each of the expected
reception messages can include data that determines the
next process to be executed and the error processing
command to be executed if there is a message reception
error.
Note: Refer to the
Protocol Support Software Operation Manual (W305)
for details.
C200HX/HG/HE
C200HW-ZW3AT1-E
Protocol Support Software
RS-232C
Standard measuring devices,
components, and personal
computers
Asynchronous (start-stop synchronization) communication
Visual Inspection
System
Intelligent Signal Processor
Temperature
Controller
Bar code reader
ID Controller
Laser micrometer
Modem
Starts pro-
cessing
Protocol
macro
executed
Sequence no. for port
specification + communica-
tions sequence no.
No.offirstwordof
output data
No.offirstwordof
input data
PMCR
Port
specification 2
Port
specification 1
Port B
Port A
Communications
sequence 000
to
Communications
sequence 999
Communications
sequence 000
to
Communications
sequence 999
Step 0
to
Step 15
Step 0
to
Step 15
Step 0
to
Step 15
Step 0
to
Step 15
Port B: 28912
Port A: 28908
95
PROGRAMMING SOFTWARE
PROTOCOL SUPPORT SOFTWARE
System Settings
Set communication conditions according to the application when
using the protocol macro for communication. The standard
communication conditions are shown here.
ITEM SPECIFICATIONS
No.ofstartbits 1
Data length 7bits
Parity Even
No.ofstopbits 2
Baud rate 9,600 bps
System Configuration
Using the protocol macro, you can customize communications
sequences for a variety of communications devices that use
RS-232C, RS-422, or RS-485 lines. Refer to the following
system configuration.
Configuration of Communication Sequences
-- A maximum of
1,000 communications sequences (i.e., communications
sequences 0 to 999) can be registered, each consisting of 16
steps max.
96
PROGRAMMING SOFTWARE
PROTOCOL SUPPORT SOFTWARE
E5AJ Temperature Controller Connection Example
Connections C200HX
Port A RS-422
AL001 RS-422 RS-422 RS-422
RS-422 RS-422 RS-422
#0 #1 #2 #3
E5AJ-A2H02 E5AJ-A2H02 E5AJ-A2H02 E5AJ-A2H02
Program Example
@PMCR
#1205
DM0506
DM1000
Start
condition PMCR
execute flag Port A specification with communications sequence 205
Setting Units and Values
DM word
DM 0506
DM 0507
DM 0508
Set data
0003
0003
0085
Meaning
No. of words for transmission data
Unit no.
Target value (85°C)
End Code:
This communications sequence is set to any word because there is
no reception data for the communications sequence.
In this example, the E5AJ is set to a target value.
C200HX/HG/HE
Mounted
directly
RS-232C
port
Host Link Module
C200H-LK201-V1
CONNECTING
CABLES
Peripheral
port
C200H-CN222/422
(2 m/4 m)
Programming Console
Connecting Cable Connecting Cable
IBM PC/AT or Compatible SYSMAC
Support Software
C500-ZL3AT1-EV1.2
C200H-PRO27-E CQM1-PRO01-E
SUPPORT
SOFTWARE
PERIPHERAL
DEVICE
Programming Console for C200H Programming Console
Connecting CableConnecting Cable
CQM1-CIF02
SYSWIN
SYSWINHL-V3.1
C200HS-CN220-EU
C200HS-CN229-EU
C500-CN221-EU
C500-CN222-EU
97
PROGRAMMING PERIPHERALS AND CABLES
OVERVIEW
These are the devices available for programming and diagnostics.
CQM1-CIF02
Connecting Cable
C200H-PRO27-E
Programming
Console
CQM1-PRO01-E
Programming Console
C200HS-CN220-EU
C200HS-CN229-EU
C500-CN221-EU
C500-CN222-EU
Connecting Cable
C200H-CN222/422
Programming Console
Connecting Cable
(2 m/4 m)
98
PROGRAMMING PERIPHERALS AND CABLES
OVERVIEW
Programming Consoles
There are two programming consoles that can be used with the
C200HX/C200HG/C200HE: The C200H-PRO27-E and the
CQM1-PRO01-E. The programming console is a complete on-
line and off-line programming and monitoring hand-held con-
sole. In addition to programming and monitoring with the pro-
gramming console, users can verify programs, compare and
create I/O tables, monitor multiple I/O, force set/reset bits, and
choose from run, monitor, debug or program modes.
The C200H-PRO27-E Programming Console connects to the
C200HX/C200HG/C200HE CPU peripheral port with
C200H-CN222 or C200H-CN422 Connecting Cable (cable
purchased separately).
The CQM1-PRO01-E Programming Console comes with a 2 m
connecting cable which connects to the C200HX, C200HG, or
C200HE CPU peripheral port.
Connecting Cables
There are several cables which allow you to connect a PC to
the C200HX/HG/HE for programming and monitoring, using
SYSWIN or SSS. The C200HS-CN220-EU (9-pin RS-232C) and
the C200HS-CN229-EU (25-pin RS-232C) cables connect a PC
to a built-in RS-232C port of the C200HX/HG/HE CPU. The
C500-CN221-EU (9-pin RS-232C) and C500-CN222-EU (25-pin
RS-232C) cables connect a PC to a rack-mounted
C200H-LK201-V1.
99
PROGRAMMING INSTRUCTIONS
GENERAL INFORMATION AND BASIC INSTRUCTIONS
General Information
Aninstructionmarkedwith“@”canbeusedasadifferentiatedinstructionthatwillbeexecutedonly
once each time the instruction executing condition is turned ON.
An instruction marked with
is an expansion instruction. These instructions must be assigned
function codes before they can be used.
An instruction marked with
is an expansion instruction. The assigned function code is the
default for the C200HX/HG/HE PLC.
Basic Instructions
NAME MNEMONIC SYMBOL FUNCTION
LOAD
LD BDefines the statusof bit B as theexecutionconditionfor
subsequent operations in the instruction line.
LOAD NOT
LD NOT BDefines the status of the inverse of bit B as the execu-
tion condition for subsequent operations in the instruc-
tion line.
AND
AND BLogically ANDs the status of the designated bit with the
current execution condition.
AND NOT
AND NOT BLogically ANDs the inverse of the designated bit with
the current execution condition.
OR
OR BLogically ORs the status of the designated bit with the
current execution condition.
OR NOT
OR NOT BLogically ORs the inverse of the designated bit with the
execution condition.
AND LOAD
AND LD LogicallyANDs theresultantexecutionconditionsofthe
preceding logic blocks.
OR LOAD
OR LD Logically ORs the resultant execution conditions of the
preceding logic blocks.
OUTPUT
OUT BTurns ON B for an ON execution condition; turns OFF
B for an OFF execution condition.
OUTPUT NOT
OUT NOT BTurns OFF B for an ON execution condition; turns ON
B for an OFF execution condition.
SET
SET SET B Turns the operand bit OFF when the execution condi-
tionis ON,anddoesnotaffectthestatus oftheoperand
bit when the execution condition is OFF.
RESET
RSET RST B Turns theoperand bit ON whenthe execution condition
is ON, and does not affect the status of the operand bit
when the execution condition is OFF.
An instruction markedwith @” can be used as adifferentiated instruction that will be executed onlyonce each time the instruction
executing condition is turned ON.
Aninstructionmarkedwith
isanexpansion instruction.Theseinstructionsmustbeassignedfunctioncodesbefore they can be
used.
Aninstructionmarkedwith
is anexpansion instruction. The assignedfunction code isthe default for theC200HX/HG/HE PLC.
100
PROGRAMMING INSTRUCTIONS
BASIC INSTRUCTIONS (CONTINUED)
NAME MNEMONIC SYMBOL FUNCTION
COUNTER
CNT CNT N
SV
CP
R
A decrementing counter. SV: 0 to 9999; CP: count
pulse; R: reset input. The TC bit is entered as a con-
stant.
REVERSIBLE COUNTER
CNTR (12) II
DI
RN
SV
CNTR(12)
Increases ordecreasesthePVby onewheneverthein-
crement input (II) or decrement input (DI) signals, re-
spectively, go from OFF to ON. SV: 0 to 9999; R: reset
input.
TIMER
TIM TIM N
SV
ON-delay (decrementing) timer operation. Set value:
000.0 to 999.9 s.
TOTALIZING TIMER
TTIM(87)
TTIM(87)
N
SV
RB
Creates a totalizing timer.
HIGH- SPEED TIMER
TIMH(15) TIMH(15) N
SV
A high-speed, ON-delay (decrementing) timer. SV:
00.02 to 99.99 s. The TC bit is entered as a constant.
END
END(01) END(01) Required at the end of each program. Instructions lo-
cated after END(01) will not be executed.
INTERLOCK
IL(02)
INTERLOCK CLEAR
ILC(03)
IL(02)
ILC(03)
Createsinterlocksusedtocontrolexecutionofprogram
sections. The entire section is reset when execution is
completed.
JUMP
JMP(04)
JUMP END
JME(05)
N
JMP(04)
JME(05) N
JUMP transfer program execution to the JUMP END
with the same number.
KEEP
KEEP(11) S
KEEP(11)
B
R
Defines abit(B) as alatch, controlledbytheset(S) and
reset (R) inputs.
NO OPERATION
NOP(00) None Nothing is executed and program operation moves to
the next instruction.
DIFFERENTIATE UP
DIFU(13) DIFU(13) BDIFU(13) turns ON the designated bit (B) for one cycle
onreceptionoftheleading(rising)edge oftheinput sig-
nal.
DIFFERENTIATE DOWN
DIFD(14) DIFD(14) BDIFD(14) turns ON the bit for one cycle on reception of
the trailing (falling) edge.
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with
is an expansion instruction. These instructions must be assigned function codes before they can be used.
An instruction marked with
is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
101
PROGRAMMING INSTRUCTIONS
DATA CONVERSION INSTRUCTIONS
NAME MNEMONIC SYMBOL FUNCTION
BCD-TO- BINARY
(@)BIN(23) BIN(23)
S
R
Converts 4-digit, BCD data in source word (S) into
16-bit binary data, andoutputs converted datato result
word (R).
S
x100
x101
x102
x103
x160
x161
x162
x163
(BCD) (BIN)
R
DOUBLE BCD-TO-DOUBLE
BINARY (@)BINL(58) BINL(58)
S
R
Converts the BCD value of the two source words (S:
starting word) into binary and outputs the converted
data to the two result words (R: starting word).
S
S+1
R
R+1
BINARY-TO- BCD
(@)BCD(24) BCD(24)
S
R
Converts binary data in source word (S) into BCD, and
outputs converted data to result word (R).
x160
x161
x162
x163
x101
x102
x103
SR
(BIN) (BCD)
x100
DOUBLE BINARY-TO-DOUBLE
BCD
(@)BCDL(59)
BCDL(59)
S
R
Converts the binary value of the two source words (S:
startingword)intoeightdigitsofBCDdata,andoutputs
the converted data to the two result words.
S
S+1
R
R+1
BIT COUNTER
(@)BCNT(67)
BCNT(67)
N
SB
R
Counts the number of ON bits in one or more words.
An instruction markedwith @” can be used as adifferentiated instruction that will be executed onlyonce each time the instruction
executing condition is turned ON.
Aninstructionmarkedwith
isanexpansion instruction.Theseinstructionsmustbeassignedfunctioncodesbefore they can be
used.
Aninstructionmarkedwith
is anexpansion instruction. The assignedfunction code isthe default for theC200HX/HG/HE PLC.
102
PROGRAMMING INSTRUCTIONS
DATA CONVERSION INSTRUCTIONS (CONTINUED)
NAME MNEMONIC SYMBOL FUNCTION
4-TO-16 DECODER
(@)MLPX(76) MLPX(76)
S
Di
R
Converts up to four hexadecimal digits in the source
word (S), into decimal values from 0 to 15, and turns
ON the corresponding bit(s) in the result word(s) (R).
S0toF
R
0015
16-TO-4 ENCODER
(@)DMPX(77) DMPX(77)
S
R
Di
Determines the position of the leftmost ON bit in the
source word(s) (starting word: S) and turns ON the cor-
responding bit(s) in the specified digit of the result word
(R).
S15 00
0toF
R
7-SEGMENT DECODER
(@)SDEC(78) SDEC(78)
S
Di
D
Converts hexadecimalvaluesfromthesourceword(S)
into 7-segment display data. Results are placed in con-
secutive half-words, starting at the first destination
word (D)
S
D0toF
ASCII CONVERT
(@)ASC(86) ASC(86)
S
Di
D
Converts hexadecimal digits from the source word (S)
into 8-bit ASCII values, starting at leftmost or rightmost
half of the starting destination word (D).
S
D8-bit
data
0toF
15 08 07 00
2’S COMPLEMENT
(@)NEG
NEG(--)
S
R
---
Converts the four-digit hexadecimal content of the
source word to its 2’s complement and outputs the re-
sult to R.
DOUBLE 2’S COMPLEMENT
(@)NEGL
NEGL(--)
S
R
---
Converts the eight-digit hexadecimal content of the
source words to its 2’s complement and outputs the re-
sult to R and R+1.
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with
is an expansion instruction. These instructions must be assigned function codes before they can be used.
An instruction marked with
is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
103
PROGRAMMING INSTRUCTIONS
DATA CONVERSION INSTRUCTIONS (CONTINUED)
NAME MNEMONIC SYMBOL FUNCTION
ASCII-TO-HEXADECIMAL
(@)HEX
HEX(--)
S
Di
D
Converts ASCII data to hexadecimal data.
0
1
2
3
D
Di: 0011
S
1st byte
2nd byte
LINE
(@)LINE(63) LINE(63)
S
C
D
Fetchesdatafromthesamenumberedbit(C)in16con-
secutive words (where S is the address of the first
source word), and creates a 4-digit word with them.
S
S+1
S+15
0
1
0
0
1
0
00
01
15
Bit C D
LINE-TO- COLUMN
(@)COLM(64)
COLM(64)
S
D
C
Places bit data from the source word(S), consecutively
into the samenumbered bits of the16 consecutive des-
tination words.
D
D+1
D+15
1
1
0
1
1
0
00
01
15
Bit CS
HOURS-TO- SECONDS
(@)SEC(65)
SEC(65)
S
R
------
Converts a time given in hours/minutes/seconds (S
and S+1) to an equivalent time in seconds only (R and
R+1).
SECONDS- TO-HOURS
(@)HMS(66)
HMS(66)
S
R
------
Converts a time given in seconds (S and S+1) to an
equivalent time in hours/minutes/seconds (R and
R+1).
ARITHMETIC PROCESS
(@)APR(69)
APR(69)
C
S
D
Calculatesthecosine, orsineofthegivendegreevalue,
or determines the y-coordinate of the given x value in a
previously established line graph.
An instruction markedwith @” can be used as adifferentiated instruction that will be executed onlyonce each time the instruction
executing condition is turned ON.
Aninstructionmarkedwith
isanexpansion instruction.Theseinstructionsmustbeassignedfunctioncodesbefore they can be
used.
Aninstructionmarkedwith
is anexpansion instruction. The assignedfunction code isthe default for theC200HX/HG/HE PLC.
104
PROGRAMMING INSTRUCTIONS
SPECIAL PROCESSING INSTRUCTIONS
NAME MNEMONIC SYMBOL FUNCTION
TRACE MEMORY SAMPLING
TRSM(45) TRSM(45) Initiates data tracing.
DISPLAY MESSAGE
(@)MSG(46) MSG(46)
FM
Displays eight words of ASCII code, starting from FM,
on the Programming Console or GPC.
FM
FM+ 7
CD
AB
DP
ABCD........DP
LONG MESSAGE
(@)LMSG(47)
LMSG(47)
S
D
------
Outputs a 32-character message to either a Program-
ming Console, or a device connected via the RS-232C
interface.Theoutputmessagemust beinASCII begin-
ning at address S.
SCALING
(@)SCL
SCL(--)
S
P1
R
Performs a scaling conversion on the calculated value.
DATA SEARCH
(@)SRCH
SRCH(--)
N
R1
C
Searches the specified range of memory for the speci-
fied data. Outputs the word address(es) of words in the
range that contain the data.
FIND MAXIMUM
(@)MAX
MAX(--)
C
R1
D
Finds the maximum value in specified data area and
outputs that value to another word.
FIND MINIMUM
(@)MIN
MIN(--)
C
R1
D
Findstheminimumvalueinspecifieddataareaandout-
puts that value to another word.
SUM
(@)SUM
SUM(--)
C
R1
D
Computes the sum of the contents of the words in the
specified range of memory.
MSB LSB
R112
R1+1 3 4
R1+2 5 6
R1+3 7 8
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with
is an expansion instruction. These instructions must be assigned function codes before they can be used.
An instruction marked with
is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
105
PROGRAMMING INSTRUCTIONS
SPECIAL PROCESSING INSTRUCTIONS (CONTINUED)
NAME MNEMONIC SYMBOL FUNCTION
FRAME CHECKSUM
(@)FCS
FCS(--)
C
R1
D
Checks for errors in data transmitted by a
Host Link command.
MSB LSB
R112
R1+1 3 4
R1+2 5 6
R1+3 7 8
AVERAGE VALUE
(@)AVG
AVG(--)
S
N
D
Adds the specified number of hexadecimal words and
computes the mean value. Rounds off to 4 digits past
the decimal point.
FAILURE POINT DETECTION
FPD
FPD(--)
C
T
D
Finds errors within an instruction block.
PID CONTROL
PID
PID(--)
S
C
D
PID control is performed according to the operand and
PID parameters that are preset.
An instruction markedwith @” can be used as adifferentiated instruction that will be executed onlyonce each time the instruction
executing condition is turned ON.
Aninstructionmarkedwith
isanexpansion instruction.Theseinstructionsmustbeassignedfunctioncodesbefore they can be
used.
Aninstructionmarkedwith
is anexpansion instruction. The assignedfunction code isthe default for theC200HX/HG/HE PLC.
106
PROGRAMMING INSTRUCTIONS
DATA SHIFTING INSTRUCTIONS
NAME MNEMONIC SYMBOL FUNCTION
SHIFT REGISTER
SFT(10) I
P
R
SFT(10)
St
E
Creates a bit shift register for data from the starting
word (St) through to the ending word (E).
ESt
15 15
00
IN
00
REVERSIBLE SHIFT
REGISTER
(@)SFTR(84)
SFTR(84)
C
St
E
Shifts bits in the specified words either left or right.
Starting (St) and ending words (E) must be specified.
CY
ESt
15
00
CY
E
IN
S
tIN
00 15 00
15 00 15
ASYNCHRONOUS SHIFT REG-
ISTER
(@)ASFT(17)
ASFT(17)
E
St
C
Creates and controls a reversible non-synchronous
word shift register between St and E. Exchanges the
contentofawordcontainingzerowiththecontentofei-
ther the preceding or following word, depending on the
shift direction.
WORD SHIFT
(@)WSFT(16) WSFT(16)
E
St
The data in the words from the starting word (St)
through to the ending word (E), is shifted left in word
units, writing all zeros into the starting word.
ARITHMETIC SHIFT LEFT
(@)ASL(25) ASL(25)
Wd Each bit within a single word ofdata (Wd)is shifted one
bittotheleft,withzerowrittentobit00andbit15moving
to CY.
Wd
15 00
CY 0
ARITHMETIC SHIFT RIGHT
(@)ASR(26) ASR(26)
Wd Each bit within a single word of data (Wd) is shifted one
bit to the right, with zero written to bit 15andbit 00 mov-
ingtoCY.
0Wd CY
15 00
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with
is an expansion instruction. These instructions must be assigned function codes before they can be used.
An instruction marked with
is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
107
PROGRAMMING INSTRUCTIONS
DATA SHIFTING INSTRUCTIONS (CONTINUED)
NAME MNEMONIC SYMBOL FUNCTION
ROTATE LEFT
(@)ROL(27) ROL(27)
Wd
Each bit within a single word of data (Wd)is moved one
bit to the left, with bit 15 moving to carry (CY), and CY
moving to bit 00.
15 00
CY
Wd
ROTATE RIGHT
(@)ROR(28) ROR(28)
Wd
15 00
CY Wd
Each bit within a single word of data (Wd) is moved one
bit to the right, with bit 00 moving to carry (CY), and CY
moving to bit 15.
ONE DIGIT SHIFT LEFT
(@)SLD(74) SLD(74)
St
E
Shifts all data, between the starting word (St) and end-
ing word (E), one digit (four bits) to the left, writing zero
into the rightmost digit of the starting word.
E
St
St + 1
0
ONE DIGIT SHIFT RIGHT
(@)SRD(75) SRD(75)
E
St
St 0
Shifts all data, between starting word (St) and ending
word(E),onedigit(fourbits)totheright,writingzerointo
the leftmost digit of the ending word.
E
E--1
An instruction markedwith @” can be used as adifferentiated instruction that will be executed onlyonce each time the instruction
executing condition is turned ON.
Aninstructionmarkedwith
isanexpansion instruction.Theseinstructionsmustbeassignedfunctioncodesbefore they can be
used.
Aninstructionmarkedwith
is anexpansion instruction. The assignedfunction code isthe default for theC200HX/HG/HE PLC.
108
PROGRAMMING INSTRUCTIONS
BCD ARITHMETIC INSTRUCTIONS
NAME MNEMONIC SYMBOL FUNCTION
BCD ADD
(@)ADD(30) ADD(30)
Au
Ad
RCY
Adds two 4-digit BCD values (Au and Ad) and content
ofCY,andoutputstheresult to thespecifiedresultword
(R).
Au + Ad + RCY
DOUBLE BCD ADD
(@)ADDL(54) ADDL(54)
Au
Ad
R
Adds two 8-digit values (2 words each) and the content
of CY, and outputs the result.
Au+ 1
+Ad+ 1
+
CY R+ 1
CY
Au
Ad
R
BCD SUBTRACT
(@)SUB(31) SUB(31)
Mi
Su
R
Subtracts both the 4-digit BCD subtrahend (Su) and
content of CY, from the 4-digit BCD minuend (Mi) and
outputs the result to the specified result word (R).
CYMi -- Su -- R CY
DOUBLE BCD SUBTRACT
(@)SUBL(55) SUBL(55)
Mi
Su
R
Subtractsboththe8-digitBCDsubtrahendandthecon-
tent of CY from an 8-digit BCD minuend, and outputs
the result.
Mi + 1 Mi
-- Su + 1 Su
--
CY R + 1 R
CY
BCD MULTIPLY
(@)MUL(32) MUL(32)
Md
R
Mr
Multiplies the 4-digit BCD multiplicand (Md) and 4-digit
BCD multiplier (Mr), and outputs the result to the speci-
fied result words (R and R + 1).
Md x Mr R+1 R
DOUBLE BCD MULTIPLY
(@)MULL(56) MULL(56)
Md
Mr
R
Multiplies the 8-digit BCD multiplicand and 8-digit BCD
multiplier, and outputs the result.
Md+ 1 Md
Mr+ 1 Md
R+3 R+2 R+1 R
X
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with
is an expansion instruction. These instructions must be assigned function codes before they can be used.
An instruction marked with
is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
109
PROGRAMMING INSTRUCTIONS
BCD ARITHMETIC INSTRUCTIONS (CONTINUED)
NAME MNEMONIC SYMBOL FUNCTION
BCD DIVIDE
(@)DIV(33)
R
DIV(33)
Dd
Dr
Divides the 4-digit BCD dividend (Dd) by the 4-digit
BCD divisor (Dr), and outputs the result to the specified
resultwords.Rreceives thequotient;R+1receives the
remainder.
R+1 R
Dd ÷Dr
DOUBLE BCD DIVIDE
(@)DIVL(57) DIVL(57)
Dd
Dr
R
Divides the 8-digit BCDdividendby an 8-digit BCD divi-
sor, and outputs the result.
Dd + 1 Dd
Dr + 1 Dr
R+1 R
R+3 R+2
Quotient
Remainder
÷
SET CARRY
(@)STC(40) STC(40) Sets the Carry Flag (i.e., turns CY ON).
CLEAR CARRY
(@)CLC(41) CLC(41) Clears the Carry Flag (i.e, turns CY OFF).
INCREMENT
(@)INC(38) INC(38)
Wd
Increments the value of a 4-digit BCD word (Wd) by
one, without affecting carry (CY).
DECREMENT
(@)DEC(39) DEC(39)
Wd Decrements the value of a 4-digit BCD word by 1, with-
out affecting carry (CY).
SQUARE ROOT
(@)ROOT(72) ROOT(72)
Sq
R
Computes the square root of an 8-digit BCD value (Sq
andSq+1)andoutputsthetruncated4-digit,integerre-
sult to the specified result word (R).
Sq+1 Sq
R
FLOATING POINT
DIVIDE
(@)FDIV(79)
FDIV(79)
Dd
Dr
R
Divides one floating point value by anotherand outputs
a floating point result.
÷
Dd+ 1 Dd
Dr+ 1 Dr
R+1 R
An instruction markedwith @” can be used as adifferentiated instruction that will be executed onlyonce each time the instruction
executing condition is turned ON.
Aninstructionmarkedwith
isanexpansion instruction.Theseinstructionsmustbeassignedfunctioncodesbefore they can be
used.
Aninstructionmarkedwith
is anexpansion instruction. The assignedfunction code isthe default for theC200HX/HG/HE PLC.
110
PROGRAMMING INSTRUCTIONS
ADVANCED I/O INSTRUCTIONS
NAME MNEMONIC SYMBOL FUNCTION
TEN KEY INPUT
TKY
TKY(--)
IW
D1
D2
Inputs 8 digits of BCD data from a 10-key keypad.
HEXADECIMAL KEY INPUT
HKY
HKY(--)
IW
OW
D
This instruction inputs 8 digits in hexadecimal from a
hexadecimal keyboard.
DIGITAL SWITCH INPUT
DSW
DSW(--)
IW
OW
R
Inputs 4- or 8-digit BCD data from a digital switch.
7-SEGMENT DISPLAY OUTPUT
7SEG
7SEG(--)
S
O
C
Converts 4- or 8-digit BCD data to 7-segment display
format and then outputs the converted data.
MATRIX INPUT
MTR
MTR(--)
IW
OW
D
Inputs data from an 8 input point ×8 output point matrix
and records that data in D to D+3.
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with
is an expansion instruction. These instructions must be assigned function codes before they can be used.
An instruction marked with
is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
111
PROGRAMMING INSTRUCTIONS
SUBROUTINE INSTRUCTIONS
NAME MNEMONIC SYMBOL FUNCTION
SUBROUTINE ENTRY
(@)SBS(91) SBS(91) NCalls subroutine N. Moves program operation to the
specified subroutine.
SUBROUTINE DEFINE
SBN(92) SBN(92) NMarks the start of subroutine N.
SUBROUTINE RETURN
RET(93) RET(93) Marks the end ofa subroutine and returns control to the
main program.
MACRO
(@)MCRO(99) MCRO(99)
N
I1
O1
Calls and executes a subroutine replacing I/O words.
INTERRUPT CONTROL
(@)INT(89)
INT(89)
CC
N
D
Controls scheduled interrupts and interrupts from Inter-
rupt Input Units.
An instruction markedwith @” can be used as adifferentiated instruction that will be executed onlyonce each time the instruction
executing condition is turned ON.
Aninstructionmarkedwith
isanexpansion instruction.Theseinstructionsmustbeassignedfunctioncodesbefore they can be
used.
Aninstructionmarkedwith
is anexpansion instruction. The assignedfunction code isthe default for theC200HX/HG/HE PLC.
112
PROGRAMMING INSTRUCTIONS
DATA COMPARISON INSTRUCTIONS
NAME MNEMONIC SYMBOL FUNCTION
COMPARE
(@)CMP(20) CMP(20)
Cp1
Cp2
Compares the data in two 4-digit hexadecimal words
(Cp1 and Cp2) and outputs result to the GR, EQ, or LE
Flags.
SIGNED BINARY COMPARE
(@)CPS
CPS(--)
Cp1
Cp2
Compares two 16-bit (4-digit) signed binary values and
outputs the result to the GR, EQ, and LE flags.
DOUBLE COMPARE
CMPL(60) CMPL(60)
S1
S2
Compares the 8-digit hexadecimal values in words
S1+1 and S1with the values in S2+1 and S2, and
indicates the result using the GreaterThan, Less Than,
and Equal Flags.
DOUBLE SIGNED BINARY
COMPARE
(@)CPSL
CPSL(--)
Cp1
Cp2
Compares two 32-bit (8-digit) signed binary values and
outputs the result to the GR, EQ, and LE flags.
BLOCK
COMPARE
(@)BCMP(68)
BCMP(68)
S
CB
R
Compares a 1-word binary value (S) with the 16 ranges
given in the comparison table (CB is the starting word of
the comparison block). If the value falls within any of the
ranges, the corresponding bits in the result word (R) will
be set.
S
CB CB+1
CB+2 CB+3
CB+4 CB+5
CB+30 CB+31
1
0
1
0
Lower limit Upper limit
Lower limit SUpper limit 1
Result
TABLE COMPARE
(@)TCMP(85) TCMP(85)
CD
TB
R
Compares a 4-digit hexadecimal value (CD) with val-
ues in table consisting of 16 words. If the value of CD
falls within anyof the comparisonranges, correspond-
ing bits in result word (R) are set.
CD Tb
Tb+1
Tb+13
Tb+14
Tb+15
1: same
0: different
0
1
1
0
1
R
0
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with
is an expansion instruction. These instructions must be assigned function codes before they can be used.
An instruction marked with
is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
113
PROGRAMMING INSTRUCTIONS
DATA COMPARISON INSTRUCTIONS (CONTINUED)
NAME MNEMONIC SYMBOL FUNCTION
MULTI-WORD COMPARE
(@)MCMP(19)
MCMP(19)
D
S2
S1
Compares the data within a block of 16 words of 4-digit
hexadecimal data (S1to S1+15) with that in another
block of 16 words (S2to S2+15) on a word-by-word ba-
sis. If the words arenot the same, the bitcorresponding
to different words turns ON in the result word, D.
AREA RANGE COMPARE
ZCP(88)
ZCP(--)
CD
LL
UL
Comparesawordtoarangedefinedbylowerandupper
limitsandoutputstheresulttotheGR,EQ,andLEflags.
DOUBLE AREA RANGE
COMPARE
ZCPL
ZCPL(--)
CD
LL
UL
Compares an 8-digit value to a range defined by lower
and upper limits and outputs the result to the GR, EQ,
and LE flags.
An instruction markedwith @” can be used as adifferentiated instruction that will be executed onlyonce each time the instruction
executing condition is turned ON.
Aninstructionmarkedwith
isanexpansion instruction.Theseinstructionsmustbeassignedfunctioncodesbefore they can be
used.
Aninstructionmarkedwith
is anexpansion instruction. The assignedfunction code isthe default for theC200HX/HG/HE PLC.
114
PROGRAMMING INSTRUCTIONS
DATA TRANSFER INSTRUCTIONS
NAME MNEMONIC SYMBOL FUNCTION
MOVE
(@)MOV(21) MOV(21)
S
D
Transfers data from source word, (S) to destination
word (D).
MOVE NOT
(@)MVN(22) MVN(22)
S
D
Transfers the inverse of the data in the source word (S)
to destination word (D).
BLOCK TRANSFER
(@)XFER(70) XFER(70)
N
S
D
Moves the content of consecutive source words (S
gives the address of the starting source word) to con-
secutivedestinationwords(D isthestartingdestination
word).
S
S+1
D
D+1
S+N--1 D+N--1
BLOCK SET
(@)BSET(71) BSET(71)
S
St
E
Copiesthecontentof oneword orconstant(S)tosever-
al consecutive words (from the starting word, St,
through to the ending word, E).
SSt
E
MOVE BIT
(@)MOVB(82) MOVB(82)
S
Bi
D
Transfers the designated bit of the source word or con-
stant (S) to the designated bit of the destination word
(D).
S
D
TRANSFER BITS
@XFRB(62)
XFRB(--)
C
S
D
Copies the status of up to 255 specified source bits to
the specified destination bits.
MOVE DIGIT
(@)MOVD(83) MOVD(83)
S
Di
D
Moves hexadecimal content of up to four specified 4-bit
source digit(s) from the source word to the specified
destination digit(s).
S
D
15 00
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with
is an expansion instruction. These instructions must be assigned function codes before they can be used.
An instruction marked with
is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
115
PROGRAMMING INSTRUCTIONS
DATA TRANSFER INSTRUCTIONS (CONTINUED)
NAME MNEMONIC SYMBOL FUNCTION
NETWORK SEND
(@)SEND(90) SEND(90)
S
D
C
Transfers data from n source words (S is the starting
word) to the destination words (D is the first address) in
node N of the specified network (in a SYSMAC LINK or
NET Link System).
NETWORK RECEIVE
(@)RECV(98) RECV(98)
S
D
C
Transfers data from the source words (S is the first
word) from node N of the specified network (in a SYS-
MAC LINK or NET Link System) to the destination
words starting at D.
SINGLE WORD
DISTRIBUTE
(@)DIST(80)
DIST(80)
S
DBs
Of
Moves one word of source data (S) to the destination
given by the destination base word (DBs) plus offset
(Of).
SBase (DBs)
+
Offset (OF)
(S) (DBs + Of)
DATA COLLECT
(@)COLL(81) COLL(81)
SBs
Of
D
Extracts data from the source word and writes it to the
destination word (D).
Base (DBs)
+
Offset (OF)
(SBs+Of) (D)
EXPANSION DM READ
(@)XDMR
XDMR(--)
N
S
D
The contents of the designated number of words of the
fixedexpansionDMdataarereadandoutputtothedes-
tination word on the PLC side.
RECEIVE
(@)RXD
RXD(--)
D
C
N
Receives data via a communications port.
An instruction markedwith @” can be used as adifferentiated instruction that will be executed onlyonce each time the instruction
executing condition is turned ON.
Aninstructionmarkedwith
isanexpansion instruction.Theseinstructionsmustbeassignedfunctioncodesbefore they can be
used.
Aninstructionmarkedwith
is anexpansion instruction. The assignedfunction code isthe default for theC200HX/HG/HE PLC.
116
PROGRAMMING INSTRUCTIONS
DATA TRANSFER INSTRUCTIONS (CONTINUED)
NAME MNEMONIC SYMBOL FUNCTION
TRANSMIT
(@)TXD
TXD(--)
S
C
N
Sends data via a communications port.
EM CONSTANT BLOCK
TRANSFER
(@)XFR2
XFR2
W
S
N
Sends data of more than one word existing in series
from the designated word to the words following the
designatedword.Whenaconstantisdesignatedwhere
the data is sent to or sent from, the EM area is desig-
nated.
EM CONSTANT INTERBANK
BLOCK TRANSFER
(@)BXF2
BXF2
C
S
D
Sends data of more than one word existing in series
from the designated word to the words following the
designated word. If the designated word is in an EM
area, the bank number can be specified.
SETUP CHANGE
(@)STUP
STUP
N
S
Sends the designated word content (for 5 words) to the
system setting area of designated RS-232 port.
EXPANSION DM BANK
CHANGE
(@)EMBC
EMBC
N
Changes the current bank of the Expansion DM.
INDIRECT EXPANSION DM
SETTING
(@)IEMS
IEMS
C
Switches the indirect execution area between DM and
EM. Current bank can be switched when changing to
EM.
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with
is an expansion instruction. These instructions must be assigned function codes before they can be used.
An instruction marked with
is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
117
PROGRAMMING INSTRUCTIONS
LOGIC INSTRUCTIONS
NAME MNEMONIC SYMBOL FUNCTION
LOGICAL AND
(@)ANDW(34) ANDW(34)
I1
I2
R
Logically ANDs two 16-bit input words (I1 and I2) and
sets the bits in the result word (R) if the corresponding
bits in the input words are both ON.
LOGICAL OR
(@)ORW(35) ORW(35)
I1
I2
R
Logically ORs two 16-bit input words (I1 and I2) and
sets the bits in the result word (R) when one or both of
the corresponding bits in the input words is/are ON.
EXCLUSIVE OR
(@)XORW(36) XORW(36)
I1
I2
R
Exclusively ORs two 16-bit input words (I1 and I2) and
setsthebitsintheresultword(R)whenthecorrespond-
ing bits in input words differ in status.
EXCLUSIVE NOR
(@)XNRW(37) I1
I2
R
XNRW(37) Exclusively NORstwo16-bitinputwords (I1andI2)and
setsthebitsintheresultword(R)whenthecorrespond-
ing bits in both input words have the same status.
COMPLEMENT
(@)COM(29) COM(29)
Wd Inverts bit status of one word (Wd) of data, changing 0s
to 1s, and vice versa.
Wd

An instruction markedwith @” can be used as adifferentiated instruction that will be executed onlyonce each time the instruction
executing condition is turned ON.
Aninstructionmarkedwith
isanexpansion instruction.Theseinstructionsmustbeassignedfunctioncodesbefore they can be
used.
Aninstructionmarkedwith
is anexpansion instruction. The assignedfunction code isthe default for theC200HX/HG/HE PLC.
118
PROGRAMMING INSTRUCTIONS
SYSTEM PROCESSING INSTRUCTIONS
NAME MNEMONIC SYMBOL FUNCTION
FAILURE ALARM
(@)FAL(06) FAL(06)NAssigns a failure alarm code to the given execution
condition. This code is generated as an error code
whenever the instruction is executed.
SEVERE FAILURE ALARM
FALS(07) FALS(07) NAfatalversionofFAL(06).WhenaFALS(07)instruction
is executed the CPU is stopped and the number is gen-
erated as an error code.
CYCLE TIME
(@)SCAN(18)
SCAN(18)
Mi
------
------
Sets the minimum cycle time, Mi, in tenths of millisec-
onds. The possible setting rangeis from 0 to 999.0 ms.
TERMINAL MODE
(@)TERM(48)
TERM(48)
------
------
------
Shifts the Programming Console to TERMINAL mode.
WATCHDOG TIMER
REFRESH
(@)WDT(94)
WDT(94) TSetsthemaximumandminimumlimitsforthewatchdog
timer (normally 0 to 130 ms). New limits:
Maximum time = 130 + (100 x T)
Minimum time = 130 + (100 x (T--1))
I/O REFRESH
(@)IORF(97) IORF(97)
St
E
Can refresh I/O words allocated to CPU or Expansion
I/O Racks and Special I/O Modules.
GROUP-2 HIGH-DENSITY I/O
REFRESH
(@)MPRF(61)
MPRF(61)
St
E
Refreshes I/O words allocated to Group-2High-density
I/O Modules.
INTELLIGENT IO READ
(@)IORD
IORD
C
S
D
Reads data of more than one word from an ASCII
Module, etc.
INTELLIGENT IO WRITE
(@)IORW
IOWR
C
S
D
Writes data of more than one word from a PLC’s CPU
to an ASCII Module.
PROTOCOL MACRO
(@)PMCR
PMCR
C
S
D
By calling the send/receive sequence (protocol data)
registered in the Communication Board connected to a
PLC’s CPU, data can be sent to or received from
another personal computer that has RS-232C.
CARD MACRO
(@)CMCR
CMCR
C
S
D
Reads orwrites files in thememory card of thePC Card
Module.
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with
is an expansion instruction. These instructions must be assigned function codes before they can be used.
An instruction marked with
is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
119
PROGRAMMING INSTRUCTIONS
STEP LADDER INSTRUCTIONS
NAME MNEMONIC SYMBOL FUNCTION
STEP DEFINE
STEP(08) STEP(08) BWhen used with a control bit (B), defines the start of a
newstepandresetsthepreviousstep.Whenusedwith-
out B, it defines the end of step execution.
STEP START
SNXT(09) SNXT(09) BUsedwithacontrolbit(B)toindicatetheendofthestep,
reset the step, and start the next step which has been
defined with the same control bit.
An instruction markedwith @” can be used as adifferentiated instruction that will be executed onlyonce each time the instruction
executing condition is turned ON.
Aninstructionmarkedwith
isanexpansion instruction.Theseinstructionsmustbeassignedfunctioncodesbefore they can be
used.
Aninstructionmarkedwith
is anexpansion instruction. The assignedfunction code isthe default for theC200HX/HG/HE PLC.
120
PROGRAMMING INSTRUCTIONS
BINARY ARITHMETIC INSTRUCTIONS
NAME MNEMONIC SYMBOL FUNCTION
BINARY ADD
(@)ADB(50) ADB(50)
Au
Ad
R
+CY
Adds the 4-digit augend (Au), 4-digit addend (Ad), and
content of CY and outputs the result to the specified re-
sult word (R).
Ad
Au
+
R
CY
DOUBLE BINARY ADD
(@)ADBL
ADBL(--)
Au
Ad
R
Adds two 8-digit binary values (normal or signed data)
and contents of carry, and outputs the result to R and
R+1.
Au + 1 Au
Ad + 1 Ad
R+1 R
CY
CY
+
BINARY SUBTRACT
(@)SBB(51) SBB(51)
Mi
Su
R
Subtracts the 4-digit hexadecimal subtrahend (Su) and
content of carry, from the 4-digit hexadecimal minuend
(Mi), and outputs the result to the specified result word
(R).
Mi
Su
CY
R
CY


DOUBLE BINARY SUBTRACT
(@)SBBL
SBBL(--)
Mi
Su
R
Subtracts an 8-digit binary value (normal or signed
data) and contents of carry from another and outputs
the result to R and R+1.
Mi+1 Mi
Su + 1 Su
R+1 R
CY
CY
--
BINARY MULTIPLY
(@)MLB(52) MLB(52)
Md
Mr
R
Multipliesthe4-digithexadecimalmultiplicand(Md)and
4-digit multiplier (Mr), and outputs the 8-digit hexadeci-
mal result to the specified result words (R and R+1).
Md
Mr
R+1
X
R
An instruction marked with “@” can be used as a differentiated instruction that will be executed only once each time the instruction
executing condition is turned ON.
An instruction marked with
is an expansion instruction. These instructions must be assigned function codes before they can be used.
An instruction marked with
is an expansion instruction. The assigned function code is the default for the C200HX/HG/HE PLC.
121
PROGRAMMING INSTRUCTIONS
BINARY ARITHMETIC INSTRUCTIONS (CONTINUED)
NAME MNEMONIC SYMBOL FUNCTION
SIGNED BINARY MULTIPLY
(@)MBS
MBS(--)
Md
Mr
R
Multiplies the signed binary content of two words and
outputs the 8-digit signed binary result to R+1 and R.
Md
Mr
R+1 R
X
DOUBLE SIGNED BINARY
MULTIPLY
(@)MBSL
MBSL(--)
Md
Mr
R
Multiplies two 32-bit (8-digit) signed binary values and
outputs the 16-digit signed binary result to R+3 through
R.
Md + 1 Md
Mr + 1 Mr
R+1 RR+3 R+2
X
BINARY DIVIDE
(@)DVB(53) DVB(53)
Dd
Dr
R
Divides the 4-digit hexadecimal dividend (Dd) by the
4-digit divisor (Dr), and outputs result to the designated
result words ( R and R + 1).
Dd
Dr
R
R+ 1
÷
Quotient
Remainder
SIGNED BINARY DIVIDE
(@)DBS
DBS(--)
Dd
Dr
R
Divides one 16-bit signed binary value by anotherand
outputs the 32-bit signed binary result to R+1 and R.
DdDr
R R+1
Quotient Remainder
DOUBLE SIGNED BINARY
DIVIDE
(@)DBSL
DBSL(--)
Dd
Dr
R
Divides one 32-bit signed binary value by another
and outputs the 64-bit signed binary result to R+3 to
R.
R+1 R
QuotientRemainder
Dd+1 DdDr+1 Dr
R+3 R+2
An instruction markedwith @” can be used as adifferentiated instruction that will be executed onlyonce each time the instruction
executing condition is turned ON.
Aninstructionmarkedwith
isanexpansion instruction.Theseinstructionsmustbeassignedfunctioncodesbefore they can be
used.
Aninstructionmarkedwith
is anexpansion instruction. The assignedfunction code isthe default for theC200HX/HG/HE PLC.
122
STANDARD P ARTS
STANDARD PARTS 123
123
124 U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
CPU RACK
CPU Rack
ITEM DESCRIPTION PART NUMBER STANDARDS
CPUs (All models are provided with
l
k
f
t
i
d
l
t
f
UM DM I/O points RS-232C U, C, N, CE
C
U
s
(
o
d
e
s
a
e
o
d
e
d
clock function and slots for commu-
n
i
c
a
t
i
o
n
s
e
x
c
e
p
t
C
P
U
1
1
-
E
)
3.2K words 4K words 640 No C200HE-CPU11-E
n
i
ca
t
i
ons excep
t
C
P
U
1
1
-
E
.
)
7.2K words 6K words 880 No C200HE-CPU32-E
8K words Yes C200HE-CPU42-E
15.2K words 12K words No C200HG-CPU33-E
Yes C200HG-CPU43-E
1,184 No C200HG-CPU53-E
Yes C200HG-CPU63-E
31.2K words 24K words 880 No C200HX-CPU34-E
Yes C200HX-CPU44-E
1,184 No C200HX-CPU54-E
Yes C200HX-CPU64-E
Power Supply Modules 100 to 120/200 to 240 VAC C200HW-PA204
100 to 120/200 to 240 VAC (with 24-VDC output terminals) C200HW-PA204S
24 VDC C200HW-PD024
CPU I/O Backplanes 3slots C200HW-BC031
5slots C200HW-BC051
8slots C200HW-BC081
10 slots C200HW-BC101
Communication Boards Communications port for SYSMAC LINK and
SYSMAC NET Link Modules C200HW-COM01
RS-232C port C200HW-COM02
RS-422/485 port C200HW-COM03
Communications port for the SYSMAC LINK Module and SYSMAC
NET Link Module and a protocol macro function C200HW-COM04-E
Two RS-232C ports and a protocol macro function C200HW-COM05-E
RS-422/485 port, an RS-232C port, and a protocol macro function C200HW-COM06-E
Memory Cassettes EEPROM 4K words C200HW-ME04K N, CE
y
8K words C200HW-ME08K
16K words C200HW-ME16K N
32K words C200HW-ME32K N, CE
EPROM 16K words/32K words C200HS-MP16K L, CE
Equivalent to 27256, 150 ns, 12.5 V ROM-JD-B CE
Equivalent to 27512, 150 ns, 12.5 V ROM-KD-B
125
U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
EXPANSION
Expansion Rack
ITEM DESCRIPTION PART NUMBER STANDARDS
Power Supply Modules 100 to 120/200 to 240 VAC C200HW-PA204 U, C, N, CE
100 to 120/200 to 240 VAC (with 24-VDC output terminals) C200HW-PA204S
24 VDC C200HW-PD024
Expansion I/O Backplanes 3slots C200HW-BI031
5slots C200HW-BI051
8slots C200HW-BI081
10 slots C200HW-BI0101
I/O Connecting Cables 30 cm The total length of the I/O Connecting Cables
d
i
t
k
t
b
1
2
i
C200H-CN311 ---
/
O
C
o
e
c
g
C
a
b
e
s
70 cm
e
o
a
e
g
o
e
/
O
C
o
e
c
g
C
a
b
e
s
used in a network must be 12 m maximum. C200H-CN711
200 cm C200H-CN221
500 cm C200H-CN521
1,000 cm C200H-CN131
Slave Rack
Slave Racks Remote I/O Slave
M
o
d
u
l
e
s
100 to 120/200 to 240 VAC (switchable) APF/
P
C
F
C200H-RT001-P U, C, N, L
M
o
d
u
l
es 24 VDC
P
C
F
C200H-RT002-P N, L
100 to 120/200 to 240 VAC (switchable) Wired C200H-RT201 U, C, N, L
C200H-RT201-C CE
24 VDC C200H-RT202 N, L, CE
Backplanes 3slots C200H-BC031-V2 U, C, N, L,
C
E
5slots C200H-BC081-V2
C
E
8slots C200H-BC051-V2
10 slots C200H-BC101-V2
I/O Blocks Input Specify either 12 or 24 VDC. G71-IC16 U, C, N, L
Output G71-OD16
I/O
T
i
l
AC input Specify either 100 or 200 VAC. G7TC-IA16
/
O
Terminals DC input Specify either 12 or 24 VDC. G7TC-ID16
Output Specify either 12 or 24 VDC. G7TC-OC16
Link Adapter O/E converter; 1 connector for RS-485, 1 connector each for APF/
PCF B500-AL007-P
126 U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
I/O MODULES
ITEM DESCRIPTION PART NUMBER STANDARDS
Input
Modules AC Input Modules 8pts 100 to 120 VAC C200H-IA121 U, C, N, L
M
o
d
u
l
e
s
16 pts 100 to 120 VAC C200H-IA122 U, C, N, L
8pts 200 to 240 VAC C200H-IA221 U, C, N, L
16 pts 200 to 240 VAC C200H-IA222
DC Input Modules 8pts 12 to 24 VDC C200H-ID211 U, C, N, L, CE
16 pts 24 VDC C200H-ID212
AC/DC Input Modules 8pts 12 to 24 VAC/DC C200H-IM211
16 pts 24 VAC/DC C200H-IM212
Interrupt Input Module
(see note) 8pts 12 to 24 VDC C200HS-INT01 U, C
Output
M
o
d
u
l
e
s
Relay Output Modules 8pts 2 A, 250 VAC/24 VDC (for resistive load) C200H-OC221 U, C, N, L
Modules 12 pts 2 A, 250 VAC/24 VDC (for resistive load) C200H-OC222
5pts 2 A, 250 VAC/24 VDC (for resistive load)
Independent commons C200H-OC223
8pts 2 A, 250 VAC/24 VDC (for resistive load)
Independent commons C200H-OC224
16 pts 2 A, 250 VAC/24 VDC (for resistive load)
(see note) C200H-OC225
Triac Output Modules 8pts 1 A, 120 VAC C200H-OA121-E U, C
8pts 1 A, 200 VAC C200H-OA223 N, L, CE
12 pts 0.3 A, 200 VAC C200H-OA222V CE
Transistor Output
M
o
d
u
l
e
s
8pts 1A,12to48VDC C200H-OD411 U, C, N, L, CE
Modules 12 pts 0.3A,24VDC C200H-OD211
16 pts 0.3 A, 24 VDC (see note) C200H-OD212
8pts 2.1A,24VDC C200H-OD213
8pts 0.8 A, 24 VDC; source type (PNP); w/load short
protection C200H-OD214 U, C, N, L
8pts 0.3 A, 5 to 24 VDC; source type (PNP) C200H-OD216
12 pts 0.3 A, 5 to 24 VDC; source type (PNP) C200H-OD217
16 pts 1 A, 24 VDC; source type (PNP); w/load short
protection C200H-OD21A CE
Analog Timer Module 4timers 0.1to1s/1to10s/10to60s/1minto10min
(switchable) C200H-TM001 U, C
Variable Resistor
Connector Connector w/lead wire (2 m) for 1 external resistor C4K-CN223 ---
B7A Interface Modules 15 or 16
input pts Connects to B7A Link Terminals. Standard trans-
mission delay. C200H-B7AI1 U, C, CE
16 output
pts Connects to B7A Link Terminals. Standard trans-
mission delay. C200H-B7AO1
(see note)
Note: If the Interrupt Input Module is mounted on an Expansion I/O Rack, the interrupt function cannot be used and the Interrupt Input Module will be
treated as an ordinary 8-point Input Module. Moreover, Interrupt Input Modules cannot be used on Slave Racks.
127
U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
SPECIAL I/O MODULES (INCLUDING GROUP 2 I/O)
Group-2 I/O Modules
ITEM DESCRIPTION PART NUMBER STANDARDS
DC Input Modules 32 pts 24 VDC C200H-ID216 U, C, N, L,
C
E
64 pts C200H-ID217 CE
Transistor Output
M
o
d
u
l
e
s
32 pts 16 mA at 4.5 V to 100 mA at 26.4 V C200H-OD218 U, C, N, L
Modules 64 pts C200H-OD219
B7A Interface Modules 32 input pts Connects to B7A Link Terminals. Standard
h
i
h
d
t
i
i
d
l
C200H-B7A12 ---
(GROUP 2 I/O MODULES) 32 output pts or high-speed transmission delay. C200H-B7A02
(
G
R
O
U
P
2
I
/
O
M
O
D
U
L
E
S
)
16 input and 16
output points C200H-B7A21
32 input and 32
output points C200H-B7A22
Special I/O Modules
ITEM DESCRIPTION PART NUMBER STANDARDS
High-density
I
/
O
M
d
l
DC Input Modules 32 pts 5 VDC (TTL inputs); w/high-speed input C200H-ID501 U, C, N, L,
C
E
g
y
I/O Modules
(
s
e
e
n
o
t
e
1
)
32 pts 24 VDC; w/high-speed input C200H-ID215
,
,
,
,
CE
(
see no
t
e
1
)
Transistor Output
Modules 32 pts 0.1 A, 24 VDC (useable as 128-point dynamic
output unit) C200H-OD215
32 pts 35 mA, 5 VDC (TTL outputs) (useable as
128-point dynamic output unit) C200H-OD501
DC Input/Transistor
Output Modules 16 input and
16 output pts 24-VDC inputs; w/high-speed input; 0.1-A,
24-VDC outputs (useable as 128-point dynamic
input unit)
C200H-MD215
16 input and
16 output pts 5-VDC TTL inputs; w/high speed input; 35-mA,
5-VDC TTL outputs (useable as 128-point dy-
namic input unit)
C200H-MD501
16 input and
16 output pts 12-VDC TTL inputs; w/high speed input;
12-VDC TTL outputs (useable as 128-point dy-
namic input unit)
C200H-MD115 N, L
Analog I/O
Modules Analog Input
Modules 4 to 20 mA, 1 to 5/0 to 10 V (switchable); 4 inputs; 12 bits C200H-AD001 U, C, N, L
4 to 20 mA, 1 to 5/0 to 10 V/--10 to 10V (switchable); 8 inputs; 12
bits or BCD C200H-AD002
Analog Output
Modules 4 to 20 mA, 1 to 5/0 to 10 V (switchable); 2 outputs C200H-DA001
4 to 20 mA, --10 to 10 V; 4 outputs C200H--DA002 ---
Fuzzy Logic Module Programmed using the Fuzzy Support Software. C200H-FZ001 N
Fuzzy Support
Software Available on either 3.5” or 5.25” floppy disks. C500-SU981-E ---
Temperature Sensor Module Thermocouple K(CA) or J(IC), switchable; 4 inputs C200H-TS001 U, C
K(CA) or L(Fe-CuNi) DIN standards; 4 inputs C200H-TS002
Pt resistance
t
h
e
r
m
o
m
e
t
e
r
Pt 100 ; 4 inputs C200H-TS101
thermometer Pt 100 ; 4 inputs; DIN and 1989 JIS standards C200H-TS102
128 U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
SPECIAL I/O (CONTINUED)
ITEM DESCRIPTION PART NUMBER STANDARDS
Temperature Control Modules Thermocouple Transistor output C200H-TC001 U, C
Voltage output C200H-TC002
Current output C200H-TC003
Pt resistance
t
h
e
r
m
o
m
e
t
e
r
Transistor output C200H-TC101
t
h
ermome
t
er Voltage output C200H-TC102
Current output C200H-TC103
Heat/Cool
T
e
m
p
e
r
a
t
r
e
C
o
n
t
r
o
l
M
o
d
l
e
s
Thermocouple Transistor output C200H-TV001
Temperature Control Modules Voltage output C200H-TV002
Current output C200H-TV003
Pt resistance
t
h
e
r
m
o
m
e
t
e
r
Transistor output C200H-TV101
t
h
ermome
t
er Voltage output C200H-TV102
Current output C200H-TV103
Cam Positioner Module Detects angles of rotation by means of a resolver and pro-
vides ON and OFF outputs at specified angles. A maximum of
48 cam outputs (16 external outputs and 32 internal outputs) max-
imum are available.
C200H-CP114
Data Setting Console Used to set and monitor data in Temperature Control Modules and
Cam Positioner Modules. C200H-DSC01
Connecting Cables 2m C200H-CN225 ---
g
4m C200H-CN425
PID Control Modules Transistor output; 4 to 20 mA/1 to 5 V/0 to 5V/0 to 10 V inputs
(selectable) C200H-PID01 U, C
Voltage output; 4 to 20 mA/1 to 5 V/0 to 5V/0 to 10 V inputs
(selectable) C200H-PID02
Current output; 4 to 20 mA/1 to 5 V/0 to 5V/0 to 10 V inputs
(selectable) C200H-PID03
Position Control Modules 1axis Pulse output; directly connects to servomotor
driver; compatible with line driver; speeds: 1 to
250,000 pps
C200H-NC112 U, C, CE
2axis Pulse output; speeds: 1 to 250,000 pps, 53 pts
per axis C200H-NC211 U, C
High-speed Counter Modules 1axis Pulse input; counting speed: 50 kcps; 5
VDC/12 VDC/24 VDC C200H-CT001-V1 U, C, CE
1axis Pulse input; counting speed: 75 kcps; RS-422
line driver C200H-CT002
2axis Pulse input; counting speed: 75 kcps; RS-422
line driver C200H-CT021
ASCII/BASIC Modules 24K-byte RAM and 24K-byte EEPROM are built-in. C200H-ASC02 CE
129
U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
SPECIAL I/O (CONTINUED)
ITEM DESCRIPTION PART NUMBER STANDARDS
RFID Sensor Modules Local application, electromagnetic coupling C200H-IDS01-V1 U, C
Remote application; microwave transmissions C200H-IDS21 ---
Read/Write Heads Electromagnetic type V600-H series
Microwave type V620-H series
Data Carriers SRAM type for V600-H series. V600-D

R

EEPROM type for V600-H series. V600-D

P

Voice Module 60 messages max.; message length: 32, 48, or 64 s (switchable) C200H-OV001
Connecting Cable RS-232C C200H-CN224
Motion Control Module G-language programmable 2-axis analog outputs C200H-MC221 ---
MC Support Software IBM PC/AT or compatible CV500-ZN3AT1-E
Connecting cable 3.3 m CQM1-CIF02
Teaching Box --- CVM1-PRS71
Connection cable for
Teaching Box 2 m long CV500-CN224
Memory Pack
(with key sheet)
(see note 2)
--- CVM1-MP701
Terminal Block
Conversion Unit Simplifies wiring for I/O connectors. XW2B-20J6-6
Connecting cable for
Terminal Block Conver-
sion Unit
XW2Z-100J-F1
Note: 1. WhenmountingaHigh-densityI/OModuleasaSpecialI/OModuletoaSlaveRack,theRemoteI/OMastermustbetheC200H-RM001-PV1or
C200H-RM201.
2. The CV-series Programming Console can be used as a Teaching Box by replacing the Memory Pack of the Programming Console.
130 U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
I/O MODULE ACCESSORIES
ITEM DESCRIPTION PART NUMBER
I/O Terminal BLock Cover For 10 pin I/O Terminal Blocks C200H-COV02
/
O
e
a
o
c
C
o
e
For 19 pin I/O Terminal Blocks C200H-COV03
For 5- and 8- point Modules C200H-COV11
Connector 24-pin, solder type, straight C500-CE241
C
o
e
c
o
24-pin, crimp type C500-CE242
24-pin, for ribbon cable C500-CE243
24-pin, solder type, 90°angle C500-CE244
40-pin, solder type, straight C500-CE401
40-pin, crimp type C500-CE402
40-pin, for ribbon cable C500-CE403
40-pin, solder type, 90°angle C500-CE404
RS-232C, 25 pins 0020756-4, RS-232 connector
RS-422, 9 pins 0020757-2, RS-422 connector
Connector Cover RS-232C, 25 pins 0020758-0, RS-232 cover
RS-422, 9 pins 0020759-9, RS-422 cover
131
U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
COMMUNICATION MODULES
ITEM DESCRIPTION PART NUMBER STANDARDS
PC Card Module A memory card suitable for Phoenix PCM+3.2 and one of the following
Bus Connection Units is required. No PC card is provided with the mod-
ule.
C200HW-PCU01-E ---
Ethernet Set A floppy disk containing Ethernet setup utility data is provided. One of
the following Bus Connection Units is required. No PC card is provided
with the Module.
C200HW-PCS01-E
Bus Connection
Units For 1 Module C200HW-CE011
For 2 Modules C200HW-CE012
SYSMAC LINK Module
(coaxial cable) A Bus Connection Unit must be ordered sepa-
rately. Data link table:
918 words C200HW-SLK23 U, C, N
y
Data link table:
2,966 words C200HW-SLK24
Terminator One required for each node at ends of System. C1000H-TER01 ---
Attachment
Stirrup Provided with SYSMAC LINK Module. C200H-TL001
F Adapter To connect network C1000H-CE001
F Adapter Cover To connect network C1000H-COV01
SYSMAC LINK Module
(fiber-optic cable) Connect with H-PCF cable. A Bus Connection
Unit must be ordered separately. Data link table:
918 words C200HW-SLK13 U, C, N
y
Data link table:
2,966 words C200HW-SLK14
Power Supply
Adapter Required when supplying backup power For 1 or 2
Modules C200H-APS03 U, C
Power Cable Connects Power Supply Adapter and SYSMAC NET
L
i
k
M
d
l
For 1 Module C200H-CN111 ---
y
Link Module. For 2 Modules C200H-CN211
SYSMAC LINK Support
Board (coaxial cable) To connect IBM PC/AT or compatible as node in SYSMAC LINK system 3G8F5-SLK21-E
SYSMAC NET LINK
Module A Bus Connection Unit must be ordered separately. C200HS-SNT32
Power Supply
A
d
t
Required when supplying backup power For 1 Module C200H-APS01
o
e
S
u
y
Adapter
e
q
u
e
d
e
s
u
y
g
b
a
c
u
o
e
For 2 Modules C200H-APS02
Power Cable Connects Power Supply Adapter
and SYSMAC NET Link Module. Included with
C200H-APS01 For 1 Module C200H-CN001
Included with
C200H-APS02 For 2 Modules C200H-CN002
Bus Connection Units Connects SYSMAC LINK Module or SYSMAC NET
Link Module to CPU. For 1 Module C200HW-CE001 N
L
i
n
k
M
o
d
u
l
e
t
o
C
P
U
.For 2 Modules C200HW-CE002
Host Link Modules Rack-mounting C200H, C200HS,
C200HE, APF/PCF C200H-LK101-PV1 N, L
C
2
0
0
H
E
,
C200HG,
C200HX RS-422 C200H-LK202-V1 U, C
RS-232C C200H-LK201-V1
DeviceNet Scanner Module Number of I/O points: 1,600 max.
Number of Slave Modules: 50 max. C200HW-DRM21 U, C, N
132 U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
COMMUNICATION MODULES AND SYSMAC NET/SYSMAC LINK
ITEM DESCRIPTION PART NUMBER STANDARDS
PC Link
Module Single level: 32 Modules
Multilevel: 16 Modules RS-485 C200H-LK401 N, L
Remote I/O Master
Modules Up to two per PLC; connectable to up to 5 Slaves per
PLC total APF/PCF C200H-RM001-PV1
Wired C200H-RM201
Remote I/O Slave Modules For reference, see
Slave Racks
on page 125 (also page 84).
Note: Only a single PC Card Module can used with the CPU.
SYSMAC NET/SYSMAC LINK Hardware
ITEM DESCRIPTION PART NUMBER STANDARDS
SYSMAC NET Network Support
Board For IBM PC/AT or compatible S3200-NSB11-E ---
SYSMAC LINK Network Support
Board For IBM PC/AT or compatible, coaxial cable connector 3G8F5-SLK21-E
133
U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
FIBER-OPTIC COMMUNICATION MODULE CONNECTIONS
3GS3200 Connectors (S3200 is the Part No. prefix.)
SYSMAC NET SYSMAC LINK SYSMAC WAY SYSMAC
BUS/2 SYSMAC BUS
C200H COCF2511 COCF2511 COCH82 COCH82
C1000H, C2000H COCH62M COCF2011 COCH82 COCH82
CVM1, CV500, CV1000, CV2000 COCF2011 COCF2011 COCF2011 COCF2011 COCF2011
SYSMAC NET Network Support
Board COCH62M
SYSMAC NET Line Server COCH62M
SYSMAC NET Bridge COCH62M
SYSMAC NET Network Service
Unit COCH62M
SYSMAC NET VME Interface COCH62M
3G5A2 Connectors (-P modules only) 3G5A2 is the Part No. prefix. B500 Part No. prefixes are equivalent to 3G5A2 prefixes.
SYSMAC WAY SYSMAC BUS
C200H CO001, CO002 CO001, CO002
C1000H, C2000H CO001, CO002 CO001, CO002
CVM1, CV500, CV1000, CV2000 CO001, CO002
All Plastic Fiber-optic (APF) Cable
ITEM DESCRIPTION PART NUMBER
Fiber-optic Cable 20 m (65.6 ft.), without connectors B500-PF212
Fiber-optic
C
o
n
n
e
c
t
o
r
s
Brown, for cable 0 to 10 m (0 to 32.8 ft.) long (includes 2) 3G5A2-CO001
b
e
o
c
Connectors Black, for cable 8 to 20 m (0 to 65.6 ft.) long (includes 2) 3G5A2-CO002
Hard Plastic-Clad Fiber-optic (HPCF) Cable
ITEM DESCRIPTION PART NUMBER
Fiber-optic
C
b
l
50 m (164 ft.), without connectors FCS-HCR-LB-501
b
e
o
c
Cable 100 m (328 ft.), without connectors FCS-HCR-LB-102
500 m (0.31 mile), without connectors FCS-HCR-LB-502
1 km (0.62 mile), without connectors FCS-HCR-LB-103
Zipcord style, orange, 50 m (164 ft.), without connectors FCS-HCR-CO-501
Fiber-optic
C
t
SYSMAC BUS or SYSMAC WAY only S3200-COCH82
b
e
o
c
Connectors SYSMAC BUS/2 (all PLCs), SYSMAC LINK (other than C200H) S3200-COCF2011
SYSMAC NET (other than C200H) S3200-COCH62M
SYSMAC NET, LINK (C200H only) S3200-COCF2511
In-line Fiber-optic
C
t
SYSMAC NET In-line male connector S3200-COCF62M
e
b
e
o
c
Connectors SYSMAC NET In-line female connector S3200-COCF62F
SYSMAC LINK In-line adapter S3200-COIAT2000
Termination Kit For HPCF Cable FCS-CAK6230-US
Plastic-Clad Fiber-optic (PCF) Cable
ITEM DESCRIPTION PART NUMBER
Indoor Fiber-optic
C
b
l
10 cm (0.32 ft.), with connectors 3G5A2-OF011
Cable 1 m (3.2 ft.), with connectors 3G5A2-OF101
2 m (6.56 ft.), with connectors 3G5A2-OF201
3 m (9.8 ft.), with connectors 3G5A2-OF301
5 m (16.4 ft.), with connectors 3G5A2-OF501
10 m (32.8 ft.), with connectors 3G5A2-OF111
20 m (65.6 ft.), with connectors 3G5A2-OF211
30 m (98 ft.), with connectors 3G5A2-OF311
50 m (164 ft.), with connectors 3G5A2-OF511
Indoor/Outdoor
F
i
b
t
i
C
b
l
100 m (328 ft.), with connectors 3G5A2-OF002-100M
d
o
o
/
O
u
d
o
o
Fiber-optic Cable 200 m (656 ft.), with connectors 3G5A2-OF002-200M
400 m (0.25 mile), with connectors 3G5A2-OF002-400M
800 m (0.5 mile), with connectors 3G5A2-OF002-800M
134 U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
LINK ADAPTERS
ITEM DESCRIPTION PART NUMBER STANDARDS
Link Adapters 3 RS-422 connectors 3G2A9-AL001 N, L
3 fiber-optic connectors (APF/PCF) 3G2A9-AL002-PE N
3 fiber-optic connectors (PCF) 3G2A9-AL002-E
1 connector for RS-232C; 2 for RS-422 3G2A9-AL003 ---
1 connector each for APF/PCF, RS-422, and RS-232C 3G2A9-AL004-PE N, L
1 connector each for PCF, RS-422, and RS-232C 3G2A9-AL004-E
1 connector each for APF/PCF and APF 3G2A9-AL005-PE ---
1 connector each for PCF and AGF 3G2A9-AL005-E
1 connector for APF/PCF; 2 for AGF 3G2A9-AL006-PE
1 connector for PCF; 2 for AGF 3G2A9-AL006-E
O/E converter; 1 connector for RS-485, 1 connector each for
APF/PCF B500-AL007-P N, L
Used for on-line removal of SYSMAC NET Link Units from
the SYSMAC NET Link System, SYSMAC NET Fiber-optic
Link Adapter (3 connectors for APF/PCF)
B700-AL001 ---
135
U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
PROGRAMMING DEVICES
ITEM DESCRIPTION PART NUMBER STANDARDS
Programming Consoles Provided with a 2-m cable for ladder programming C200H-PRO27-E U, C
One of the following connection cables is required for lad-
der programming. CQM1-PRO01-E
Programming Console
Mounting Bracket Used to attach Hand-held Programming Console to a
panel. C200H-ATT01 ---
Programming Console
C
o
n
n
e
c
t
i
n
g
C
a
b
l
e
s
For C200H-PRO27-E Hand-held
P
r
o
g
r
a
m
m
i
n
g
C
o
n
s
o
l
e
2m C200H-CN222
Connecting Cables Programming Console C200HS-CN222 CE
4m C200H-CN422 ---
C200HS-CN422 CE
Data Setting Console Used for data input and process value display for the
C200H-TC

.C200H-DSC01 ---
Data Setting Console
C
o
n
n
e
c
t
i
n
g
C
a
b
l
e
s
For C200H-DSC01 2m C200H-CN225
C
o
n
n
e
c
t
i
n
g
C
a
b
l
e
s
4m C200H-CN425
Connecting Cable Used to connect an IBM PC/AT or
compatible to the C200HX/HG/HE. 3.3 m CQM1-CIF02
136 U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
OPTIONAL PRODUCTS
ITEM DESCRIPTION PART NUMBER STANDARDS
I/O Module
Cover Cover for 10-pin terminal block C200H-COV11 ---
Terminal Block Covers Short protection for 10-pin terminal block (package of 10 covers); 8 pts C200H-COV02
Short protection for 19-pin terminal block (package of 10 covers); 12 pts C200H-COV03
Connector Cover Protective cover for unused I/O Connecting Cable connectors C500-COV02
Space Module Used for vacant slots C200H-SP001 N, L
Battery Set For C200H or C200HS RAM Memory Unit only C200H-BAT09 ---
Relay 24 VDC G6B-1174P-FD-US
CPU Backplane
I
n
s
u
l
a
t
i
o
n
P
l
a
t
e
s
For 3-slot Backplane C200H-ATT31 ---
Insulation Plates For 5-slot Backplane C200H-ATT51
For 8-slot Backplane C200H-ATT81
For 10-slot Backplane C200H-ATTA1
I/O Backplane
I
n
s
u
l
a
t
i
o
n
P
l
a
t
e
s
For 3-slot Backplane C200HW-ATT32 N
I
nsu
l
at
i
on
P
l
ates For 5-slot Backplane C200HW-ATT52
For 8-slot Backplane C200HW-ATT82
For 10-slot Backplane C200HW-ATTA2 ---
External Connectors Solder terminal; 40p and a Connector Cover C500-CE401
Solderless terminal; 40p and a Connector Cover (Crimp-type) C500-CE402
Pressure welded terminal; 40p C500-CE403
Solder terminal; 40p and a Connector Cover (Horizontal-type) C500-CE404
Crimp-style terminal; 40p and a Connector Cover (Horizontal-type) C500-CE405
137
U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
MOUNTING RAIL AND MOUNTING ACCESSORIES
ITEM DESCRIPTION PART NUMBER STANDARDS
DIN Rail Mounting
Bracket 1 set (2 included) C200H-DIN01 ---
DIN Rails Length: 50 cm; height: 7.3 cm PFP-50N
Length: 1 m; height: 7.3 cm PFP-100N
Length: 1 m; height: 16 mm PFP-100N2
End Plate --- PFP-M
Spacer --- PFP-S
Note: Order DIN Rails, End Plates, and Spacers in units of 10 each.
138 U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
SOFTWARE
SYSMAC Support Software (SSS)
ITEM DESCRIPTION PART NUMBER
SYSMAC Support Software
(for C20, C

P, C

K,
C120, C

H, C200H,
C200HS, C200HE, C200HG,
C200HX, C500, C1000H,
C2000H, CQM1, and CVM1)
3.5”, 2HD for IBM PC/AT compatible C500-ZL3AT1-EV1.2
SYSWIN
ITEM DESCRIPTION PART NUMBER
SYSWIN
(for C20, C

P, C

K,
C120, C

H, C200H,
C200HS, C200HE,
C200HG, C200HX, C500,
C1000H, C2000H, CQM1,
and CVM1)
3.5”, 2HD for IBM PC/AT compatible SYSWINHL-V3.0
Protocol Support Software (PSS)
ITEM DESCRIPTION PART NUMBER
Protocol Support Software 3.5”, 2HD for IBM PC/AT compatible C200HW-ZW3AT1-E
Motion Control Support Software (MCSS) -- for C200H-MC221 Motion Control Module ONLY
ITEM DESCRIPTION PART NUMBER
Motion Control
Support Software 3.5”, 2HD for IBM PC/AT compatible CV500-ZN3AT1-E
139
U: UL, C: CSA, N: NK, L: LLOYD, CE: EC Directives -- See OMRON sales representatives for conditions under which UL,
CSA, NK, LLOYD, and CE standards were met.
MANUALS
PLC Installation, Operation
ITEM DESCRIPTION PART NUMBER
C200HX/C200HG/C200HE PLCs Installation Guide W302
C200HX/C200HG/C200HE PLCs Operation Guide W303
C200HW-COM01-C200HW-COM06-E Operation Guide W304
C200HW-ZW3AT1-E Protocol
Software Operation Guide W305
Special I/O Modules
ITEM DESCRIPTION PART NUMBER
C200H-PCU01/PCS01 PC Card Module W313
C200H-ASC02 ASCII/BASIC Module W165
C200H-AD001, C200H-DA001 Analog I/O Modules W127
C200H-AD002 Analog Input Module W229
C200H-DA002 Analog Output Module W260
C200H-CT001-V1/CT002 High-speed Counter Modules W141
C200H-CT021 High-speed Counter Modules W311
C200H-TS001/TS002 Temperature Sensor Input Modules W124
C200H-TC

Temperature Control Module W225
C200H-TV

Heat/Cool Temperature Control Module W240
C200H-PID

PID Control Module W241
C200H-CP114 Cam Positioner Module W224
C200H-NC111 Position Control Module W137
C200H-NC112 Position Control Module W128
C200H-NC221 Position Control Module W166
C200H-IDS01/IDS21 ID Sensor Module W153
C200H-OV001 Voice Module W172
C200H-MC221 Motion Module W314 / W315 / W256
C200H-FZ001 Fuzzy Logic Module W208
Communications
ITEM DESCRIPTION PART NUMBER
C200HW-SLK

SYSMAC Link Modules W174
C200HS-SNT32 SYSMAC Net Module W114
C200H-LK401 PC Link Module W135
C200H-LK20
Host Link Modules W143
SYSBUS Wired Remote I/O System manual W120
SYSBUS Fiber-Optic Remote I/O System manual W136
DeviceNet System manual W267
Peripheral Devices
ITEM DESCRIPTION PART NUMBER
C200H-DAC01 W173
GPC (Graphics Programming
Console) Operation manual W84
FIT (Factory Intelligent Terminal) Operation manual W150
Printer Interface Module Operation manual W107
PROM Writer Operation Guide Procedures for programming EPROM W155
Floppy Disk Interface Module Procedures for interfacing with floppy disk W119
Programming Software
ITEM DESCRIPTION PART NUMBER
SYSMAC Support Software Programming procedures using SSS W247/W248
SYSWIN Support Software Programming procedures using SYSWIN SYSWIN-EMAN-V

140
COMPLEMENTARY PRODUCTS
COMPLEMENTARY 141
PRODUCTS
Operator Interface Terminals 142
141
MODEL NT11S NT20S NT30 NT30C
DISPLAY
Size 4 line x 20 character 5" diagonal 5.7" diagonal 5.7" diagonal
Type Backlit LCD Backlit STN LCD Bicolor backlit STN LCD 8-color backlit STN LCD
Resolution 160 x 64 pixels 256 x 128 pixels 320 x 240 pixels 320 x 240 pixels
Interface Alphanumeric Touch screen Touch screen Touch screen
Touch cells 72 per screen 192 per screen 192 per screen
FEATURES Large characters Slim profile Bicolor display 8-color display
Contrast control Easy to configure screens Full graphic capabilities Full graphic capabilities
Password protect screens Replaceable backlight Replaceable backlight Replaceable backlight
MEMORY
Type Flash EPROM Flash EPROM Flash EPROM Flash EPROM
Size 32 K 64-92 K 512 K 512 K
Max. # of screens 250 screens 250 screens 2000 screens 2000 screens
GRAPHIC CAPABILITIES
Freeform drawing
Bitmap
Tiling
Bar graph
Line trending
Thumbwheel switch
Text and numeric
Real-Time
Clock
Printer Port
Communication Host Link / NT Link Host Link / NT Link / Host Link / NT Link Host Link / NT Link
C200H Interface
Overall 218W x 113H x 38.2D mm 190W x 110H x 58D mm 195W x 142H x 55.6D mm 195W x 142H x 55.6D mm
Dimensions 8.58W x 4.45H x 1.50D in 7.48W x 4.33H x 2.28D in 7.68W x 5.59H x 2.19D in 7.68W x 5.59H x 2.19D in
ENVIRONMENTAL
Ratings NEMA 4 NEMA 4 NEMA 4 NEMA 4
Approvals UL / CSA UL / CSA UL / CSA UL / CSA
Accessories Backlight Backlight Backlight
Chemical resistant cover Chemical resistant cover Chemical resistant cover
Protective sheet Protective sheet Protective sheet
C200H Interface B7A Interface B7A Interface
OPERATOR INTERFACE TERMINALS
Easy to order, with no complicated configuration (communications and memor y are built-in), the NT Series Ter minals
provide a v ariety of control options. F rom the basic 4 line x 20 char acter , te xt-based NT11S to our g raphic touch screen
models — including the slim NT20S (with a depth of only 54 mm) and the eight-color NT620C — our new line of termi-
nals can be relied on for clear, dependab le data presentation. And with Omron’ s Host Link and NT Link communication
methods, fast response times between terminal and PLC are guaranteed. Direct connection to the C200H backplane is
also available on some models for an even faster response. Combine this with Omron’s NT Support Software and you
get a powerful operator interface that’s easy to read and quick to connect with screens that are simple to create.
142
COMPLEMENTARY PRODUCTS
MODEL NT600S (LCD) NT600S (EL) NT620S NT620C
DISPLAY
Size 9" diagonal 9" diagonal 9" diagonal 9.7" diagonal
Type Backlit STN LCD Electroluminescent Electroluminescent 8-color backlit STN LCD
Resolution 640 x 400 pixels 640 x 400 pixels 640 x 400 pixels 640 x 480 pixels
Interface Touch screen Touch screen Touch screen Touch screen
Touch cells 128 per screen 128 per screen 512 per screen 768 per screen
FEATURES Large screen Clear EL display Clear EL display 8-color display
Slim profile Extra-wide viewing angle Full graphic capabilities Full graphic capabilities
Replaceable backlight Slim profile Extra-wide viewing angle Replaceable backlight
MEMORY
Type Flash EPROM Flash EPROM Flash EPROM Flash EPROM
Size 128 K 128 K 512 K 1 MB
Max. # of screens 500 screens 500 screens 2000 screens 2000 screens
GRAPHIC CAPABILITIES
Freeform drawing
Bitmap
Tiling
Bar graph
Line trending
Thumbwheel switch
Text and numeric
Real-Time
Clock
Printer Port
Communication Host Link / NT Link Host Link / NT Link / Host Link / NT Link Host Link / NT Link
C200H Interface C200H Interface
Overall 275W x 192H x 71D mm 275W x 192H x 71D mm 275W x 192H x 71D mm 275W x 196H x 76.8D mm
Dimensions 10.83W x 7.56H x 2.80D in 10.83W x 7.56H x 2.80D in 10.83W x 7.56H x 2.80D in 10.83W x 7.72H x 3.02D in
ENVIRONMENTAL
Ratings NEMA 4 NEMA 4 NEMA 4 NEMA 4
Approvals UL / CSA UL / CSA UL / CSA UL / CSA
Accessories Backlight Chemical resistant cover Chemical resistant cover Backlight
Chemical resistant cover Protective sheet Protective sheet Chemical resistant cover
Protective sheet C200H Interface Protective sheet
C200H Interface
OPERATOR INTERFACE TERMINALS
143
COMPLEMENTARY PRODUCTS
1:1 NT Link
RS-232C port
Host
15 m max. Operator
Interface
Terminal
Host
Host Link
Module
CPU
RS-422 Cable
500 m max. Operator
Interface
Terminal
Operator
Interface
Terminal
Host
Host Link
Module
CPU
Host Link Cable
Host
I/O Expansion Port
10 m max.
I/O Expansion Cable
Operator
Interface
Terminal
Distance: 15 m max.
144
OPERATOR INTERFACE TERMINAL
COMMUNICATIONS OPTIONS
Direct Access Function greatly reduces programming effort
of the host. The Direct Access Function enables the user to
directly access the relay area and DM area of the Host. Using
this function, the user can greatly reduce the PLC programming
effort that is required for the Operator Interface Terminals. The
C200HX/HG/HE Interface and NT Link are ideal for applications
that require high-speed input operations.
NT Link
Greatly reduces ladder programming required for controlling
the Operator Interface Terminals.
Enables a faster I/O response by using a dedicated
communications protocol.
RS-422 Host Link Connection
Greatly reduces ladder programming required for controlling
the Operator Interface Terminals.
Ideal for a long-distance transmission with 1:1 connection.
RS-232C Host Link Connection
Greatly reduces ladder programming required for controlling
the Operator Interface Terminals.
One of the most popular communications systems.
C200H Backplane Connection
Greatly reduces ladder programming required for controlling
the Operator Interface Terminals.
Directly connects to the I/O expansion port of the
C200HX/HG/HE to achieve faster response and high-speed
display.
No Communications Units are required on the
C200HX/HG/HE side.
145
OPERATOR INTERFACE TERMINAL
COMMUNICATIONS OPTIONS
Communications Methods Applicable to C200HX/HG/HE
Possible to connect to the I/O expansion port
Possible to use from the Communications Module built
into the CPU (see note)
Possible to connect to the Communications Module
PLC DIRECT ACCESS FUNCTION
C
RS-232C
HOST LINK
CONNECTION
C200H
BACKPLANE
CONNECTION
NT LINK RS-422
HOST LINK
CONNECTION
C200HX/HG/HE
/
/
Note: C200HE-CPU42-E, C200HG-CPU43-E/63-E, and C200HX-CPU44-E/64-E allow
connection to the built-in port.
Communications Methods of the NT Series
OPERATOR DIRECT ACCESS FUNCTION
O
O
INTERFACE
TERMINAL RS-232C
HOST LINK
CONNECTION
C200H
BACKPLANE
CONNECTION
NT LINK RS-422
HOST LINK
CONNECTION
NT11S Yes --- Yes Yes
NT20S Yes Yes Yes ---
NT30/C Yes --- Yes Yes
NT600S Yes Yes Yes ---
NT620S/C Yes --- Yes ---
C200H-ID215
C200H-OD215
C200H-MD215
G79 Connecting
Cable
G70A I/O
Block*
G7VC Output Block
C200H-ID216
C200H-ID217
C200H-OD218
C200H-OD219
G79-I or G79-O
Connecting
Cable G70A I/O
Block*
G7VC Output Block
I
II
III
IV
G70A-ZOC16-3
I/O Block with Relays
G79 Connecting
Cable (1:1)
C200H-OD215
C200H-MD215
Connecting to High-density I/O Modules
Connecting to Group-2 I/O Modules
Connecting to I/O Modules Equipped with Connectors
Note: I to IV indicate connector numbers.
146
I/O BLOCKS
I/O Blocks Connect to High-density I/O Modules,
Mixed I/O Modules and Normal I/O Modules
G70A I/O Blocks
G70A I/O Blocks provide16 contact input or 16 contact output
points in a compact package (234 x 75 x 64 mm).
They mount to DIN track to save installation and
maintenance time.
G7VC Output Blocks
G7VC Output Blocks provide 16 output points in a compact
package (192 x 58 x 38.5 mm).
A rotating front cover provides easy access to terminals for
simplified maintenance and increased safety.
C200H-RM201
Remote I/O Master Module
G72C-ID16
G72C-OD16
G72C-VID16
G72C-VOD16
G70A-ZOC16-3
G71-OD16
Valve wiring block
(Not sold by OMRON.)
Note: Ask your OMRON dealer for more information concerning OMRON
I/O Blocks and I/O Terminals.
147
G72C/G72C-V I/O TERMINALS
G72C/G72C-V I/O Terminals In Remote I/O Systems
I/O Terminals are connected as Slaves in Remote I/O Systems
to provide for special wiring needs via wiring blocks.
Compactness in the right shape is provided by a choice
between flat terminals (182 x 85 x 45 mm) and vertical terminals
(202 x 45 x 63 mm).
32-point I/O Modules
with Connectors
(Group-2 Slaves)
64-point I/O Modules
with Connectors
(Group-2 Slaves)
32-point PLC I/O Modules
with Connectors
I/O Modules with
Terminal Blocks
C200H-ID215
C200H-OD215
C200H-MD115
C200H-MD215
C200H-MD501
C200H-ID501
C200H-OD501
XW2Z-

A
Connecting Cable
XW2B-20G
XW2Z-

F
Cable with
Loose Crimp
Connectors
XW2B-20G
XW2B-40G
C200H-ID216
C200H-OD218
C200H-ID217
C200H-OD219
Connection Examples
For 32-point I/O Modules with Connectors:
XW2Z-

A
Note: The G79-
C (Cable for G7TC) cannot be used for the XW2C.
For 32-point I/O Modules with Connectors (Group-2 Slaves) or
For 64-point I/O Modules with Connectors :
XW2Z-

B
For 32-point Input Modules with Connectors (Group-2 Slaves) or
For 64-point Input Modules with Connectors :
XW2Z-

D
Note: The G79-1
C-
(Cable for G7TC) cannot be used for the XW2C.
Cable with Loose Crimp Connectors (20 connections) :
XW2Z-

F
Connecting Cables
148
CONNECTOR TERMINAL CONVERSION UNITS/CABLES
You Can Easily Convert Between Connectors and Terminal Blocks
to Simplify Control Wiring.
XW2B
Only 45 mm wide, the XW2B connects directly to PLC I/O
Modules using special cables to simplify connection.
Snap onto DIN rail or mount with screws.
Easy panel-mounting.
XW2Z
A special cable for easy connection between PLC I/O
Modules and Connector--Terminal Conversion Units
PART NUMBER INDEX
PART NUMBER INDEX 149
149
152
PART NUMBER INDEX
C200H--TS001 42, 43, 127...............
C200H--TS101 42, 43, 127...............
C200H--TV00_ 46, 47, 128...............
C200H--TV10_ 46, 47, 128...............
C200HIA222 23, 126....................
C200HS--CN220--EU 98.................
C200HS--CN222 135....................
C200HS--CN229--EU 98.................
C200HS--CN422 135....................
C200HS--INT01 31, 32, 126..............
C200HS--MP16K 17, 124................
C200HS--SNT32 75, 76, 131..............
C200HW--ATT32 136....................
C200HW--ATT52 136....................
C200HW--ATT82 136....................
C200HW--ATTA2 136...................
C200HW--BC031 19, 124................
C200HW--BC051 19, 124................
C200HW--BC081 19, 124................
C200HW--BC101 19, 124................
C200HW--BI031 19.....................
C200HW--BI051 19.....................
C200HW--BI081 19.....................
C200HW--BI101 19.....................
C200HW--CE001 75, 76, 78, 80, 131......
C200HW--CE002 75, 76, 78, 80, 131......
C200HW--CE011 72, 73, 74, 131..........
C200HW--CE012 72, 73, 74, 131..........
C200HW--COM01 14, 75, 76, 78, 80, 124...
C200HW--COM02 14, 124................
C200HW--COM03 14, 124................
C200HW--COM04--E ....................
14, 75, 76, 78, 80, 124..............
C200HW--COM05--E 14, 124.............
C200HW--COM06--E 14, 124.............
C200HW--DRM21 81, 131................
C200HW--ME04K 17, 124................
C200HW--ME08K 17, 124................
C200HW--ME16K 17, 124................
C200HW--ME32K 17, 124................
C200HW--P___ 17, 124..................
C200HW--PA204 18, 124, 125.............
C200HW--PA204S 18, 124, 125...........
C200HW--PCS01--E 72, 73, 74, 131........
C200HW--PCU01--E 72, 73, 74, 131........
C200HW--PD024 18, 124, 125............
C200HW--SLK13/14 78, 79, 80, 131........
C200HW--SLK23/24 78, 79, 80, 131........
C200HW--ZW3AT1--E 138...............
C500--CE241 130.......................
C500--CE242 130.......................
C500--CE243 130.......................
C500--CE244 130.......................
C500--CE401 130, 136...................
C500--CE402 130, 136...................
C500--CE403 130, 136...................
C500--CE404 130.......................
C500--CE405 136.......................
C500--COV02 136......................
C500--Z3AT1--EV1.2 138................
CQM1--CIF02 98, 129, 135...............
CQM1--PRO01--E 98, 135................
CV500--CN244 129.....................
CV500--ZN3AT1--E 129, 138..............
CVM1--PRS71 129......................
F
FCS-CAK6230-US 133..................
FCS-HCR-_ _ -_ _ _ 133.................
G
G6B--1174P--FD--US 136................
G71--IC16 125.........................
G71--OD16 125........................
G7TC--IA16 125........................
G7TC--ID16 125........................
G7TC--OC16 125.......................
P
PFP--100N 137.........................
PFP--100N2 137........................
PFP--50N 137..........................
PFP--M 137............................
PFP--S 137............................
S
S300--COCH82 133.....................
S3200--COCF2011 133..................
S3200--COCF2511 133..................
S3200--COCF62F 133...................
S3200--COCF62M 133..................
S3200--COCH62M 133..................
S3200--COIAT2000 133.................
S3200--NSB11--E 132...................
SYSWINHL--V3.0 138...................
X
XW2B--20J6--6 129.....................
XW2Z--100J--F1 129....................