SIMATIC Process Control System PCS 7 Released Modules (V7.1 SP3) ET 200M 1 Gateway 2 ET 200iS 3 ET 200iSP 4 ET 200S 5 ET 200X 6 ET 200pro 7 Repeater 8 Network Components 9 Catalog Overview 05/2011 A5E02124692-03 PC 10 PCS 7 11 S7-300 12 S7-400 13 Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. CAUTION without a safety alert symbol, indicates that property damage can result if proper precautions are not taken. NOTICE indicates that an unintended result or situation can occur if the corresponding information is not taken into account. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation for the specific task, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be adhered to. The information in the relevant documentation must be observed. Trademarks All names identified by (R) are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Industry Sector Postfach 48 48 90026 NURNBERG GERMANY 04/2011 Copyright (c) Siemens AG 2011. Technical data subject to change SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version Short Description W Properties C R T ET 200M ET200M-IM 153-1 IM IM 153-1, bus interface module for S7-300 SMs, FM 350 to FM 352, FM355, CP 341, module replacement in RUN IM 153-1, bus interface module for S7-300 SMs, extended environmental conditions 6ES7 153-1AA02-0XB0 ET200M-IM 153-1, 6ES7 153-1AA82-0XB0 extended environmental conditions ET200M-IM 153-1 6ES7 153-1AA03-0XB0 ET200M-IM 153-2 6ES7 153-2AA02-0XB0 ET200M-IM 153-2 6ES7 153-2BA00-0XB0 V3.x ET200M-IM 153-2 6ES7 153-2BA01-0XB0 V4.x ET200M-IM 153-2 6ES7 153-2BA81-0XB0 V4.x ET200M-IM 153-2 6ES7 153-2BA02-0XB0 V5.x ET200M-IM 153-2 6ES7 153-2BA82-0XB0 V5.x ET200M-IM 153-2 FO 6ES7 153-2AB01-0XB0 ET200M-IM 153-2 FO 6ES7 153-2BB00-0XB0 Partition Bus Module Bus Module Bus Module Bus module 6ES7 195-1KA00-0XA0 6ES7 195-7HA00-0XA0 6ES7 195-7HB00-0XA0 6ES7 195-7HC00-0XA0 6ES7392-1AN00-0AA0 Bus module 6ES7392-1BN00-0AA0 BM IM/IM 6ES7 195-7HD00-0XA0 BM IM/IM 6ES7 195-7HD10-0XA0 F Partition bus module 6ES7 195-7HG00-0XA0 IM 153-1, bus interface module for S7-300 SMs, FM 350 to FM 352, FM355, CP 341, module replacement in RUN IM 153-1, bus interface module for S7-300 SMs, extended environmental conditions IM 153-2, bus interface module for S7-300 SMs, FMs (except FM356-4), module replacement in RUN IM 153-2, bus interface module for S7-300 SMs, FMs (except FM356-4), module replacement in RUN IM 153-2, bus interface module for S7-300 SMs, FMs (except FM356-4), module replacement in RUN, extension of process control functions. IM 153-2, bus interface module for S7-300 SMs, FMs (without FM356-4), module replacement in RUN, extension of process control functions IM 153-2 Outdoor; bus interface module for S7-300 SMs, FMs (without FM356-4), module replacement in RUN, extension of process control functions IM 153-2, bus interface module for S7-300 SMs, FMs (except FM356-4), module replacement in RUN, extension of process control functions, supports operation of up to 12 I/O modules IM 153-2 Outdoor, bus interface module for S7-300 SMs, FMs (except FM356-4), module replacement in RUN, extension of process control functions, supports operation of up to 12 I/O modules IM 153-2 with FOC hardware, bus interface module for S7-300 SMs and FMs (without FM356-4), module replacement in RUN IM 153-2, bus interface module for S7-300 SMs, FMs (except FM356-4), module replacement in RUN, extension of process control functions. Accessories Ex partition for ET 200M Active bus module for ET200M IM153; PS/IM Active bus module for ET200M IM153; 2x40mm Active bus module for ET200M IM153; 1x80mm Active bus module for ET200M IM153 for 64-channel Dx-modules Active bus module for ET200M IM153 for 64-channel Dx-modules Active bus module ET200M IM 153; IM/IM for redundant IM operation Active bus module ET200M IM 153; IM/IM for redundant IM operation Fail-safe partition bus module for ET200M F Partition bus module 6ES7 195-7KF00-0XA0 Fail-safe partition bus module for ET200M ET200M-IM 153-1, 6ES7 153-1AA83-0XB0 extended environmental conditions ET200M-IM 153-2 6ES7 153-2AA01-0XB0 V3.x X X 08/00 X X 10/05 X X X X 11/03 X X 04/00 X X 06/04 X S X X S X X S X X S X X S X X X X S 07/06 01/03 X 07/04 Refer to the manual "SIMATIC Distributed I/O Device ET 200M" for information about valid combinations of interfaces, bus modules and of available functions. Properties: W = Module wizard: C = CiR support: R = Redundant I/O: T = Type discontinued: X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; X = Supported A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 3 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version Short Description W Properties C R T Gateway PA Couplers DP/PA coupler DP/PA coupler not Ex, outdoor, 400 mA DP/PA coupler not Ex, outdoor, 400 mA DP/PA coupler not Ex, outdoor, 1000 mA, 31 V DP/PA Coupler DP/PA Coupler DP/PA Coupler DP/PA Coupler 6ES7 157-0AC00-0XA0 6ES7 157-0AC80-0XA0 6ES7 157-0AC81-0XA0 6ES7 157-0AC82-0XA0 DP/PA Coupler DP/PA Coupler DP/PA Coupler 6ES7 157-0AC83-0XA0 6ES7 157-0AD00-0XA0 6ES7 157-0AD80-0XA0 DP/PA Coupler Ex 6ES7 157-0AD81-0XA0 DP/PA Coupler Ex 6ES7 157-0AD82-0XA0 BM DP/PA Coupler 6ES7 195-7HF80-0XA0 Bus module for the DP/PA coupler (double width) BM DP/PA Coupler 6ES7 195-7HG80-0XA0 Bus module for redundant DP/PA coupler Active Field Distributor 6ES7 157-0AF81-0XA0 Active Field Splitter 6ES7 157-0AF82-0XA0 IM157 6ES7 157-0AA80-0XA0 IM157 6ES7 157-0AA81-0XA0 IM157 6ES7 157-0AA82-0XA0 V4.x SIMATIC DP, ACTIVE FIELD DISTRIBUTOR AFD FOR PROFIBUS PA RING RED. SIMATIC DP, ACTIVE FIELD DISTRIBUTOR AFS FOR PROFIBUS PA COUPLER RED. DP Link IM157, Interface module for PROFIBUS-PA; extended temperature range -25 C to +60 C IM157-2, Interface module for PROFIBUS PA, extended temperature range-25 C to +60 C DP/PA link, DPV1 to DP and PA, module replacement in RUN, reporting function, FW update via bus, extension of process control functions. IM 153-2 CU 6ES7 153-2BA01-0XB0 V4.x IM 153-2 CU Outdoor 6ES7 153-2BA81-0XB0 IM 153-2 CU 04/00 05/04 04/05 DP/PA coupler not Ex, outdoor, redundancy DP/PA coupler, Ex(i) DP/PA coupler, Ex(ib), extended environmental conditions DP/PA coupler, extended environmental conditions (ia), FM approval DP/PA coupler, extended environmental conditions (ia), FM approval, Dust approval A 07/01 12/03 05/04 X X 06/00 X X 12/03 X S DP/PA Link, DPV1 to DP and PA, module replacement in RUN, reporting function, FW update via bus, extension of process control functions X S V4.x DP/PA Link Outdoor, DPV1 to DP and PA, module replacement in RUN, reporting function, FW update via bus, extension of process control functions X S 6ES7 153-2BA02-0XB0 V5.x X S IM 153-2 CU Outdoor 6ES7 153-2BA82-0XB0 V5.x DP/PA-Link, DPV1 to DP and PA, module replacement in RUN, reporting function, FW update via bus, extension of process control functions DP/PA-Link Outdoor, DPV1 to DP and PA, module replacement in RUN, reporting function, FW update via bus, extension of process control functions, supports operation of up to 12 I/O modules X S Bus module BM IM/IM 6ES7 195-7HE80-0XA0 6ES7 195-7HD10-0XA0 BM IM/IM 6ES7 195-7HD80-0XA0 Y Coupler 6ES7 654-0YK00-0AB0 Bus Module RS485 Repeater 6ES7 654-7HY00-0XA0 6ES7 972-0AA01-0XA0 Y Coupler 6ES7 197-1LB00-0XA0 Bus module for IM157 Bus module IM157 / IM 153-2; IM / IM for redundant IM operation; Bus module IM157 / IM 153-2; IM / IM for redundant IM operation; extended temperature range Y Coupler Y coupler; Y switch for connecting single-channel I/O to the H system, simple switch Bus module for Y switch RS485 REPEATER FOR THE CONNECTION OF PROFIBUS/MPI BUS SYSTEMS, MAX. 31 NODES. MAX. BAUD RATE 12 MBIT/S, DEGREE OF PROTECTION IP20 Y coupler; Y switch for connecting a single-channel I/O to the H system, simple interface with integrated RS485 REPEATER Refer to the manual SIMATIC Bus Coupling DP/PA Link and Y link for information on valid combinations of interfaces, couplers, bus modules and on available functions. Properties: W = Module wizard: C = CiR support: R = Redundant I/O: T = Type discontinued: X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; X = Supported A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 4 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version Short Description W 6GK1 503-2CA00 V4.x PROFIBUS OLM P12 6GK1 503-3CA00 V4.x SIMATIC NET, PB OLM/P12 V4.0 OPTICAL LINK MODULE W. 1 RS485 AND 2 PLASTIC-FOCINTERFACE (4 BFOC-SOCKETS), WITH SIGNAL. CONTACT AND MEASURING OUTPUT, 4 BFOCCONNECTORS INCLUDED PROFIBUS OLM G11 6GK1 503-2CB00 V4.x SIMATIC NET, PB OLM/G11 V4.0 OPTICAL LINK MODULE W. 1 RS485 AND 1 GLASS-FOCINTERFACE (2 BFOC-SOCKETS); WITH SIGNAL. CONTACT AND MEASURING OUTPUT PROFIBUS OLM G12 6GK1 503-3CB00 V4.x PROFIBUS OLM G12EEC 6GK1 503-3CD00 V4.x SIMATIC NET, PROFIBUS OLM/G12 V4.0 OPTICAL LINK MODULE W. 1 RS485 AND 2 GLASS-FOCINTERFACES (4 BFOC-SOCKETS) FOR STANDARD DISTANCES UP TO 2850 M, WITH WITH SIGNAL. CONTACT AND MEASURING OUTPUT SIMATIC NET, PB OLM/G12-EEC V4.0 OPTICAL LINK MODULE W. 1 RS485 AND 2 GLASS-FOCINTERFACES (4 BFOC-SOCKETS) FOR EXTENDED TEMPERATURE RANGE -20..+60 DGR PROFIBUS OLM G111300 6GK1 503-2CC00 V4.x SIMATIC NET,PB OLM/G11-1300V4.0 OPTICAL LINK MODULE W. 1 RS485 AND 1 GLASS-FOCINTERFACE (2 BFOC-SOCKETS),1300NM WAVE LENGTH FOR GREAT DISTANCES WITH SIGNAL. CONTACT AND MEASURING OUTPUT PROFIBUS OLM G121300 6GK1 503-3CC00 V4.x SIMATIC NET, PB OLM/G12-1300 V4.0 OPTICAL LINK MODULE W. 1 RS485 AND 2 GLASS-FOCINTERFACES (4 BFOC-SOCKETS),1300NM WAVE LENGTH FOR GREAT DISTANCES WITH SIGNAL. CONTACT AND MEASURING OUTPUT R = Redundant I/O: T = Type discontinued: T OLM SIMATIC NET, PB OLM/P11 V4.0 OPTICAL LINK MODULE W. 1 RS485 AND 1 PLASTIC-FOCINTERFACE (2 BFOC-SOCKETS), WITH SIGNAL. CONTACT AND MEASURING OUTPUT, 2 BFOCCONNECTORS INCLUDED PROFIBUS OLM P11 Properties: W = Module wizard: C = CiR support: Properties C R X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; X = Supported A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 5 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version Short Description W Properties C R T ET 200iS AI Analog input module AI 2xI, 2-wire-MU (0..20 mA / 12 bits + sign, 4..20 mA/ 12 bits) 2 AI 2 WIRE 6ES7 134-5RB00-0AB0 2 AI 4 WIRE 6ES7 134-5RB50-0AB0 2 AI TC 6ES7 134-5SB00-0AB0 2 AI RTD 6ES7 134-5SB50-0AB0 2 AI 2 WIRE HART 6ES7 134-5TB00-0AB0 Analog input module AI2x4..20mA, with HART communication for the connection of 2-wire MU X 2 AI 4 WIRE HART 6ES7 134-5TB50-0AB0 Analog input module 2AI 4..20 mA, with HART communication for the connection of 4-wire MU X 2 AO 0/4-20mA 6ES7 135-5RB00-0AB0 2 AO HART 6ES7 135-5TB00-0AB0 4 DI NAMUR 6ES7 131-5RD00-0AB0 2 DO 6ES7 132-5SB00-0AB0 ET200iS-IM151-2 6ES7 151-2AA00-0AB0 PS 6ES7 138-5EA00-0AA0 TM-E30S-44iS 6ES7 193-5CB00-0AA0 TM-E30C-44iS 6ES7 193-5CB10-0AA0 TM-PS-iS TM-IM-iS 6ES7 193-5DA00-0AA0 6ES7 193-5DB00-0AA0 Analog input module AI 2xI, 4-wire-MU (0..20mA / 12 bits, 4..20 mA/ 12bit) Analog input module AI 2xTC / 15 bits + sign, standard, thermocouples: E, N, J, K, L, S, R, B, T, U Analog input module AI 2xRTD / 15 bits + sign, Standard, R: 600 ohms; RTD: Pt100, Ni100 AO Analog output module 2AO 0..20 mA / 12 bits + sign, 4..20mA/ 12 bits) Analog output module 2AO 4..20 mA, with HART communication DI Digital input module 4DI NAMUR DO Digital output module 2DO 25 VDC/25 mA IM Interface module for ET 200iS electronic modules for intrinsically safe PROFIBUS-DP PS Power supply for ET 200iS TM Terminal module for EMs, 4 terminal strips, screw terminals Terminal module for EMs, 4 terminal strips, springloaded terminals Terminal module for PS Terminal module for IM 151-2 X X X X X X X X X X X M X M X X X X M M M ET 200iSP 4 AI I 2WIRE HART 6ES7 134-7TD00-0AB0 4 AI I 4WIRE HART 6ES7 134-7TD50-0AB0 4 AI TC 4 AI RTD 4 AI RTD 4 F-AI 4x0/4...20mA, HART 6ES7 134-7SD00-0AB0 6ES7 134-7SD50-0AB0 6ES7 134-7SD51-0AB0 6ES7 138-7FA00-0AB0 Properties: W = Module wizard: C = CiR support: R = Redundant I/O: T = Type discontinued: AI Analog input module, 4AI 4..20 mA, with HART communication for the connection of 2-wire MU Analog input module 4AI 4..20 mA, with HART communication for the connection of 4-wire MU Analog input module AI 4xTC Analog input module AI 4xRTD Analog input module AI 4xRTD Analog input module F-AI 4x0/4...20mA, HART, safety-oriented, Ex i X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; X = Supported A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 6 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version Short Description W Properties C R T ET 200iSP 4 AO I HART 6ES7 135-7TD00-0AB0 8 DI NAMUR 8 F-DI NAMUR 6ES7 131-7RF00-0AB0 6ES7 138-7FN00-0AB0 4 DO DC23.1V/20mA 6ES7 132-7RD00-0AB0 4 DO DC23.1V/20mA Shutdown "H" 4 DO DC17.4V/27mA 6ES7 132-7RD01-0AB0 4 DO DC17.4V/27mA Shutdown "H" 4 DO DC17.4V/40mA 6ES7 132-7RD11-0AB0 ET200iSP-IM152-1 6ES7 152-1AA00-0AB0 ET200iSP-IM152-1 6ES7 152-1AA00-0AB0 PS DC 24V PS DC 24V PS AC 120/230V 6ES7 138-7EA00-0AA0 6ES7 138-7EA01-0AA0 6ES7 138-7EC00-0AA0 EM Standby module 6ES7 138-7AA00-0AA0 Watchdog module 6ES7 138-7BB00-0AB0 RS 485-IS Coupler 6ES7972-0AC80-0XA0 TM-EM/EM 60 S TM-EM/EM 60 C TM-EM relays C TM-IM/EM 60 S TM-IM/EM 60 C TM-IM/IM TM-PS-A TM-PS-B TM-PS-A TM-PS-B 6ES7 193-7CA00-0AA0 6ES7 193-7CA10-0AA0 6ES7193-7CB00-0AA0 6ES7 193-7AA00-0AA0 6ES7 193-7AA10-0AA0 6ES7 193-7AB00-0AA0 6ES7 193-7DA00-0AA0 6ES7 193-7DB00-0AA0 6ES7 193-7DA10-0AA0 6ES7 193-7DB10-0AA0 T = Type discontinued: Digital output module 4DO 17.4 VDC/27 mA Shutdown "H" Digital output module 4DO 17.4 VDC/40 mA 6ES7 132-7RD20-0AB0 6ES7 132-7HB00-0AB0 6ES7 138-7FD00-0AB0 R = Redundant I/O: Digital output module 4DO 23.1 VDC/20 mA Shutdown "H" Digital output module 4DO 17.4 VDC/27 mA 6ES7 132-7RD10-0AB0 4 DO DC17.4V/40mA Shutdown "H" 4 DO DC17.4V/40mA Shutdown "H" 4 DO DC23.1V/20mA Shutdown "L" 4 DO DC17.4V/27mA Shutdown "L" 4 DO DC17.4V/40mA Shutdown "L" 4 DO DC17.4V/40mA Shutdown "L" 4 DO DC25.5V/22mA Shutdown "L" 2 DO relays UC60V/2A 4 F-DO 4x17,4V/40mA Properties: W = Module wizard: C = CiR support: AO Analog input module 4AO 4..20 mA, with HART communication DI Digital input module 8DI NAMUR Digital input module, F-DI 8 NAMUR, safety-oriented, Ex i DO Digital output module 4DO 23.1 VDC/20 mA 6ES7 132-7RD21-0AB0 6ES7 132-7RD22-0AB0 6ES7 132-7GD00-0AB0 6ES7 132-7GD10-0AB0 6ES7 132-7GD20-0AB0 6ES7 132-7GD21-0AB0 6ES7 132-7GD30-0AB0 V2.0. Digital output module 4DO 17.4 VDC/40 mA Shutdown "H" Digital output module 4DO 17.4 VDC/40 mA Shutdown "H" Digital output module 4DO 23.1 VDC/20 mA Shutdown "L" Digital output module 4DO 17.4 VDC/27 mA Shutdown "L" Digital output module 4DO 17.4 VDC/40 mA Shutdown "L" Digital output module 4DO 17.4 VDC/40 mA Shutdown "L" Digital output module 4DO 25.5 VDC/22 mA Shutdown "L" Digital output module DO 2 x relay UC60V/2A Digital output module, F-DO 4x17,4V/40mA, P switching, safety-oriented, Ex i IM Interface module for ET 200iSP electronic modules for intrinsically safe PROFIBUS DP Interface module for ET 200iSP Electronic module for intrinsically safe PROFIBUS DP, redundant operation in H systems supported PS Power supply module for ET 200iSP Power supply module for ET 200iSP Power supply module for ET 200iSP EM Standby module for unused slots Watchdog Special module for station monitoring Coupler Fieldbus coupler for interfacing PROFIBUS DP and RS 485-IS, for controlling intrinsically safe Profibus nodes. Installation in Zone 2 is possible. Extended temperature range. Protection class IP20 TM Terminal module for 2 EMs, screw terminals Terminal module for 2 EMs, spring-loaded terminals Terminal module EM relays, screw terminals Terminal module for IM/EM, screw terminals Terminal module for IM/EM, spring-loaded terminals Terminal module for redundant IM Terminal module for power supply Terminal module for redundant power supply Terminal module for power supply Terminal module for redundant power supply X M X X M X M X M X M X M X M X M X M X M X M X M X M X M X X M X S X S 10/06 10/06 10/06 07/06 X M X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; X = Supported A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 7 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version Short Description W Properties C R T ET 200S 6ES7 134-4JB00-0AB0 AI Analog input module AI 2xV (+/-5 V, 1V to 5 V, +/-10 V) / 13 bits, standard Analog input module AI 2xV (+/-5 V, 1V to 5 V, +/-10 V) / 13 bits, standard Analog input module AI 2xI, 2-wire MU (4..20 mA) / 13 bits, standard Analog input module AI 2xI, 2-wire MU (4..20 mA) / 13 bits, standard Analog input module AI 2xI, 4-wire MU (+/-20 mA, 4..20 mA) / 13 bits, standard Analog input module AI 2xI, 4-wire MU (+/-20 mA, 4..20 mA) / 13 bits, standard Analog input module AI 2xTC / 15 bits, standard X 2 AI I TC 6ES7 134-4JB01-0AB0 Analog input module AI 2xTC / 15 bits, standard X 2 AI I RTD 6ES7 134-4JB50-0AB0 Analog input module AI 2xRTD / 15 bits, standard X 2 AI I RTD 6ES7 134-4JB51-0AB0 Analog input module AI 2xRTD / 15 bits, standard X 2 AI V 6ES7 134-4LB00-0AB0 X 2 AI V 6ES7 134-4LB02-0AB0 2 AI I 6ES7 134-4MB00-0AB0 2 AI I 6ES7 134-4MB02-0AB0 2 AI I TC High Feature 2 AI I TC High Feature 2 AI I RTD High Feature 2 AI I RTD High Feature 6ES7 134-4NB00-0AB0 Analog input module AI 2xV (+/-5 V, 1V to 5 V, +/- 10 V) / 15 bits, high resolution Analog input module AI 2xV (+/-5 V, 1V to 5 V, +/- 10 V) / 15 bits, high resolution Analog input module AI 2xI (+/-20 mA, 4..20 mA) / 15 bits, high resolution Analog input module AI 2xI (+/-20 mA, 4..20 mA) / 15 bits, high resolution 2 AI I TC High Feature; analog input module AI 2xTC 15 bits, high feature 2 AI I TC High Feature; analog input module AI 2xTC / 15 bits, high feature 2 AI I RTD High Feature; analog input module AI 2xRTD / 15 bits, high feature 2 AI I RTD High Feature; analog input module AI 2xRTD / 15 bits, high feature AO Analog output module AO 2xV (1 V to 5 V / 12 bits, +/10 V / 13 bits), standard Analog output module AO 2xV (1 V to 5 V / 12 bits, +/10 V / 13 bits), standard Analog output module AO 2xI (+/-20 mA, 4..20 mA) / 13 bits, standard Analog output module AO 2xI (+/-20 mA, 4..20 mA) / 13 bits, standard Analog output module AO 2xV (1 V to 5 V, +/-10 V) / 15 bits, high resolution Analog output module AO 2xV (1 V to 5 V, +/- 10V) / 15 bits, high resolution, isochronous mode supported. 2 AI V 6ES7 134-4FB00-0AB0 2 AI V 6ES7 134-4FB01-0AB0 2 AI I 2DMU 6ES7 134-4GB00-0AB0 2 AI I 2DMU 6ES7 134-4GB01-0AB0 2 AI I 4DMU 6ES7 134-4GB10-0AB0 2 AI I 4DMU 6ES7 134-4GB11-0AB0 2 AI I TC 6ES7 134-4NB01-0AB0 6ES7 134-4NB50-0AB0 6ES7 134-4NB51-0AB0 1) 1) 1) X 07/05 X X 04/05 X X 05/05 X 06/06 X X 06/06 X X 09/05 X X 11/05 X 2 AO V 6ES7 135-4FB00-0AB0 2 AO V 6ES7 135-4FB01-0AB0 2 AO I 6ES7 135-4GB00-0AB0 2 AO I 6ES7 135-4GB01-0AB0 2 AO V 6ES7 135-4LB00-0AB0 2 AO V 6ES7 135-4LB01-0AB0 2 AO V 6ES7 135-4LB02-0AB0 Analog output module AO 2xV (1 V to 5 V, +/-10V) / 15 bits, high resolution, isochronous mode supported. X 2 AO I 6ES7 135-4MB00-0AB0 X 08/03 2 AO I 6ES7 135-4MB01-0AB0 Analog output module AO 2xI (+/-20 mA, 4..20 mA) / 15 bits, high resolution Analog output module AO 2xI (+/-20 mA, 4..20 mA) / 15 bits, high resolution, isochronous mode supported. X 06/06 2 AO I 6ES7 135-4MB02-0AB0 Properties: W = Module wizard: C = CiR support: R = Redundant I/O: T = Type discontinued: Analog output module AO 2xI (+/-20 mA, 4..20 mA) / 15 bits, high resolution, isochronous mode supported. X 05/05 X X 05/05 X X 08/03 X 06/06 X X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; X = Supported A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 8 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version Short Description W DI 2 DI DC24V; digital input module 2DI 24 VDC, standard 2 DI DC24V; digital input module 2DI 24 VDC, standard 4 DI DC24V; digital input module 4DI 24 VDC, standard 4 DI DC24V; digital input module 4DI 24 VDC, standard Digital input module 2DI 24 VDC, High Feature; with diagnostics function Digital input module 2DI 24 VDC, High Feature; with diagnostics function Digital input module 4DI 24 VDC, High Feature; with diagnostics function Digital input module 4DI 24 VDC, High Feature; with diagnostics function Digital input module 8DI 24 VDC, supports isochronous mode 4DI; digital input module 4 DI 24 V UC to 48V UC, High Feature; with diagnostics function 4DI; digital input module 4 DI 24 V UC to 48V UC, High Feature; with diagnostics function Properties C R 2 DI DC24V 6ES7 131-4BB00-0AA0 2 DI DC24V 6ES7 131-4BB01-0AA0 4 DI DC24V 6ES7 131-4BD00-0AA0 4 DI DC24V 6ES7 131-4BD01-0AA0 2 DI DC24V High Feature 2 DI DC24V High Feature 4 DI DC24V High Feature 4 DI DC24V High Feature 8 DI DC24V High Speed 6ES7 131-4BB00-0AB0 6ES7 131-4BF00-0AA0 4DI 6ES7 131-4CD00-0AB0 4 DI UC 24..48V HF 6ES7 131-4CD02-0AB0 2 DI AC 120V 6ES7 131-4EB00-0AB0 2 DI AC 120V, digital input module 2DI 120 VAC X 2 DI AC 230V 6ES7 131-4FB00-0AB0 2 DI AC 230V; digital input module 2DI 120 VAC X 4 DI NAMUR 6ES7 131-4RD00-0AB0 4 DI NAMUR; with diagnostics function X 4 DI NAMUR 6ES7 131-4RD02-0AB0 4 DI DC 24V NAMUR; with diagnostics function X 4/8 F-DI DC 24V 6ES7 138-4FA00-0AB0 X 06/04 4/8 F-DI DC 24V 6ES7 138-4FA01-0AB0 X 10/05 4/8 F-DI DC 24V 6ES7 138-4FA02-0AB0 X 01/07 4/8 F-DI DC 24V 6ES7 138-4FA03-0AB0 4/8 F-DI DC 24V 6ES7 138-4FA04-0AB0 8 DI DC 24V; digital input module 4/8DI 24 VDC, 8 DI safety-oriented SIL-2 or 4 DI safety-oriented SIL-3, with diagnostics function 8 DI DC 24V; digital input module 4/8DI 24 VDC, 8 DI safety-oriented SIL-2 or 4 DI safety-oriented SIL-3, with diagnostics function 8 DI DC 24V; digital input module 4/8DI 24 VDC, 8 DI safety-oriented SIL-2 or 4 DI safety-oriented SIL-3, with diagnostics function 8 DI DC 24V; digital input module 4/8DI 24 VDC, 8 DI safety-oriented SIL-2 or 4 DI safety-oriented SIL-3, with diagnostics function 8 DI DC 24V; digital input module 4/8DI 24 VDC, 8 DI safety-oriented SIL-2 or 4 DI safety-oriented SIL-3, with diagnostics function Properties: W = Module wizard: C = CiR support: R = Redundant I/O: T = Type discontinued: 6ES7 131-4BB01-0AB0 6ES7 131-4BD00-0AB0 6ES7 131-4BD01-0AB0 X T 04/05 X X 04/05 X X 06/05 X X 05/05 X X X X 10/10 X X X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; X = Supported A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 9 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB 2 DO DC24V/0.5A 6ES7 132-4BB00-0AA0 2 DO DC24V/0.5A 6ES7 132-4BB01-0AA0 2 DO DC24V/2A 6ES7 132-4BB30-0AA0 2 DO DC24V/2A 6ES7 132-4BB31-0AA0 2 DO DC24V/0.5A High Feature 2 DO DC24V/0.5A High Feature 2 DO DC24V/2A High Feature 2 DO DC24V/2A High Feature 4 DO DC24V/0.5A 6ES7 132-4BB00-0AB0 6ES7 132-4BB01-0AB0 6ES7 132-4BB30-0AB0 6ES7 132-4BB31-0AB0 6ES7 132-4BD00-0AA0 FW Version Short Description W DO 2DO DC24V/0.5 A; digital output module 2DO 24 VDC/0.5 A, standard 2 DO DC24V/0.5A; digital output module 2DO 24 VDC/0.5 A, standard 2 DO DC24V/2A; digital output module 2DO 24 VDC/2 A, standard 2 DO DC24V/2A; digital output module 2DO 24 VDC/2 A, standard Digital output module 2DO 24 VDC/0.5 A, High Feature, with diagnostics function Digital output module 2DO 24 VDC/0.5 A, High Feature, with diagnostics function Digital output module 2DO 24 VDC/2 A, High Feature, with diagnostics function Digital output module 2DO 24 VDC/2 A, High Feature, with diagnostics function 4 DO DC24V/0.5A; digital output module 4DO 24 VDC/0.5 A, standard 4 DO DC24V/0.5A; digital output module 4DO 24 VDC/0.5 A, High Feature, with diagnostics function X X X X X 4 DO DC24V/0.5A 6ES7 132-4BD02-0AA0 4 DO DC24V/2A 6ES7 132-4BD30-0AA0 4 DO DC24V/2A High Feature 6ES7 132-4BD30-0AB0 4 DO DC24V/2A 6ES7 132-4BD31-0AA0 4 DO DC24V/2A 6ES7 132-4BD32-0AA0 8 DO DC24V/0.5A High Speed 6ES7 132-4BF00-0AA0 8 DO DC24V/0.5A High Feature 6ES7 132-4BF00-0AB0 8 DO DC24V/0.5A; digital output module DO 8xDC24V/0.5A, supports isochronous mode, High Feature, with diagnostics function X 2 DO AC 120/230V/ 1A 6ES7 132-4FB00-0AB0 2 DO AC 120/230V/ 1A; digital output module 2DO 120 VAC/230 VAC, 1 A 2 DO AC 120/230V/ 1A; digital output module 2DO 120 VAC/230 VAC, 1 A 2 DO Rel. 24..230V/5A; digital output module 2xRel. UC 24 V to 230 V/5 A 2 DO Rel. 24..230V/5A; digital output module 2xrel. UC 24 V to 230 V/5 A 2 DO Rel. 24..230V/5A; digital output module 2xRel. design C, UC 24 V to 230 V/5 A 2 DO Rel. 24..230V/5A; digital output module 2xRel. design C, UC 24 V to 230 V/5 A 4 DO DC 24V/2A; digital output module 4DO 24 VDC/2 A, safety-oriented up to SIL-3, with diagnostics function, PM switching 4 DO DC 24V/2A; digital output module 4DO 24 VDC/2 A, safety-oriented up to SIL-3, with diagnostics function, PM switching 4 DO DC 24V/2A; digital output module 4DO 24 VDC/2 A, safety-oriented up to SIL-3, with diagnostics function, PM switching 4 DO DC 24V/2A; digital output module DO 4xDC24V/2A, safety-oriented up to SIL-3, with diagnostics function, PM switching FM Counter module, 24 V/100 kHz for single, infinite and periodic counting, supports isochronous mode; (only counting mode and measuring mode are permitted in PCS 7) X 2 DO Rel. 24..230V/5A 6ES7 132-4HB01-0AB0 2 DO Rel. 24..230V/5A 6ES7 132-4HB10-0AB0 2 DO Rel. 24..230V/5A 6ES7 132-4HB12-0AB0 4 DO DC 24V/2A 6ES7 138-4FB00-0AB0 4 DO DC 24V/2A 6ES7 138-4FB01-0AB0 4 DO DC 24V/2A 6ES7 138-4FB02-0AB0 4 DO DC 24V/2A 6ES7 138-4FB03-0AB0 Counter module, 24 V/100 kHz 6ES7138-4DA04-0AB0 Properties: W = Module wizard: C = CiR support: R = Redundant I/O: 09/05 07/05 X 6ES7 132-4BD01-0AA0 6ES7 132-4HB00-0AB0 04/05 X 4 DO DC24V/0.5A 2 DO Rel. 24..230V/5A 04/05 X 6ES7 132-4BD00-0AB0 2 DO AC 120/230V/ 1A 6ES7 132-4FB01-0AB0 T X 4 DO DC24V/0.5A High Feature 4 DO DC24V/0.5A; digital output module 4DO 24 VDC/0.5 A, standard 4 DO DC24V/0.5A; digital output module DO 4xDC24V/0.5A, standard 4 DO DC24V/2A; digital output module 4DO 24 VDC/2 A, standard 4 DO DC24V/2A; digital output module 4DO 24 VDC/2 A, High Feature, with diagnostics function 4 DO DC24V/2A; digital output module 4DO 24 VDC/2 A, standard 4 DO DC24V/2A; digital output module 4DO 24 VDC/2 A, standard 8 DO DC24V/0.5A; digital output module DO 8xDC24V/0.5A, supports isochronous mode Properties C R 05/05 X X X X 04/05 X X 05/07 X X 01/07 X X 04/05 X X X X 06/04 X 10/05 X X X X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; X = Supported A = Redundant connection possible M = module-specific; C = channel-specific Page 10 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version Short Description W Properties C R T IM151-1 6ES7 151-1BA00-0AB0 IM Interface module IM151-1 for ET 200S, High Feature X X 10/05 IM151-1 6ES7 151-1BA01-0AB0 Interface module IM151-1 for ET 200S, high feature X X 03/07 IM151-1 6ES7 151-1BA02-0AB0 Interface module IM151-1 for ET 200S, high feature X X PM-E DC24V 6ES7 138-4CA00-0AA0 PM-E DC24V 6ES7 138-4CA01-0AA0 PM-E DC24V HF 6ES7 138-4CA60-0AB0 PM-E DC24V/ AC120/230V PM-E DC24V..48/ AC24..230V PM-E F pm DC24V 6ES7 138-4CB10-0AB0 6ES7 138-4CF00-0AB0 PM-E F pm DC24V 6ES7 138-4CF01-0AB0 PM-E F pm DC24V 6ES7 138-4CB11-0AB0 PM Power module PM-E, 24 VDC, with diagnostics function Power module PM-E, 24 VDC, with diagnostics function Power module PM-E, 24 VDC, with diagnostics function, high feature PM-E DC24V/ AC120/230V; with diagnostics function and fuse PM-E DC24..48V/ AC24..230V; with diagnostics function and fuse Power module PM-E, 24 VDC, safety-oriented with 2DO 24 VDC PM potential with diagnostics function X 04/05 X X X 11/06 X X 06/04 Power module PM-E, 24 VDC, safety oriented with 2DO 24 V PM switching; with diagnostics function X 10/05 6ES7 138-4CF02-0AB0 Power module PM-E, 24 VDC, safety-oriented, with 2DO 24 V PM switching; with diagnostics function X PM-E F pm DC24V 6ES7 138-4CF03-0AB0 Power module PM-E, 24 VDC, safety-oriented, with 2 DO 24V PM switching; with diagnostics function X PM-E DC24V 6ES7 138-4CF42-0AB0 Power module PM-E, 24 VDC, safety-oriented, PP switching; with diagnostics function X PM-D DC24V 3RK1 903-0BA00 PM-D DC24V; power module; PM-D; 2x24 VDC X PM-D F1 SIGUARD 3RK1 903-1BA00 X PM-D F2 SIGUARD 3RK1 903-1BB00 PM-D F1 SIGUARD; power module; EMERGENCY STOP; monitored start; 2 channels PM-D F2 SIGUARD; power module; protective door; auto start; 2 channel PM-D F4 SIGUARD 3RK1 903-1BC00 PM-D F3 SIGUARD 3RK1 903-1BD00 PM-D F5 SIGUARD 3RK1 903-1BE00 PM-X SIGUARD 3RK1 903-1CB00 PM-D F PROFIsafe 3RK1 903-3BA00 PM-D F PROFIsafe 3RK1 903-3BA01 Power module PROFIsafe; PM-D F PROFIsafe; for 6 switching modules; safety-oriented X PM-D F PROFIsafe 3RK1 903-3BA02 Power module PROFIsafe; PM-D F PROFIsafe; for 6 switching modules; safety-oriented X F-CM 3RK1 903-3CA00 Contact Multiplier F-CM; extension to PM-D F PROFIsafe; contact multiplier X PM-D F X1 3RK1 903-3DA00 Power/extension module PM-D F X1; overvoltage protection, for the input of external emergency OFF signals; for 6 switching modules X Properties: W = Module wizard: C = CiR support: R = Redundant I/O: T = Type discontinued: PM-D F4 SIGUARD; power module; expansion to F1/2 for further potential group PM-D F3 SIGUARD; power module; expansion to F1/2 for further potential group; time delay PM-D F5 SIGUARD; power module; expansion to PM D F1 up to PM-D F4, contact replicator PM-X, connection module for power supply contactor; external safety circuits Power module PROFIsafe; PM-D F PROFIsafe; for 6 switching modules; safety-oriented X X X X X X X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; X = Supported A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 11 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version Short Description W 6ES7 193-4CAx0-0AA0 TM-E15x24-A1 6ES7 193-4CAx0-0AA0 Terminal module for electronic modules; AUX busbar to next potential group on left; terminal connection to AUX1 potential TM-E15x24-01 6ES7 193-4CBx0-0AA0 Terminal module for electronic modules; AUX busbar to next potential group on left; no terminal connection to AUX1 potential TM-E15x23-01 6ES7 193-4CBx0-0AA0 Terminal module for electronic modules; AUX busbar to next potential group on left; no terminal connection to AUX1 potential TM-E15x24-AT 6ES7 193-4CLx0-0AA0 Terminal module for electronic modules 2 AI TC HF; AUX busbar to next potential group on left; no terminal connection to AUX1 potential TM-E30x46-A1 6ES7 193-4CFx0-0AA0 Terminal module for electronic modules; AUX busbar to next potential group on left; terminal connection to AUX1 potential TM-E30x44-01 6ES7 193-4CGx0-0AA0 TM-P15x23-A1 6ES7 193-4CCx0-0AA0 Terminal module for electronic modules; AUX busbar to next potential group on left; no terminal connection to AUX1 potential Terminal module for power modules; AUX busbar to next potential group on left; terminal connection to AUX1 potential TM-P15x23-A0 6ES7 193-4CDx0-0AA0 Terminal module for power modules; interrupted AUX rail to next potential group on left; terminal connection to AUX1 potential TM-P15x22-01 6ES7 193-4CEx0-0AA0 Terminal module for power modules; AUX busbar to next potential group on left; no terminal connection to AUX1 potential TM-P30x44-A0 6ES7 193-4CKx0-0AA0 TM-P15S27-01 3RK1 903-0AA00 TM-PF30S47-B1 3RK1 903-1AA00 TM-PF30S47-B0 3RK1 903-1AA10 TM-PF30S47-C1 3RK1 903-1AC00 TM-PF30S47-C0 3RK1 903-1AC10 TM-PF30S47-D0 3RK1 903-1AD10 TM-X15 S27-01 3RK1 903-1AB00 TM-PF30S47-F1 3RK1 903-3AA00 TM-FCM30S47-E0 3RK1 903-3AB10 TM-PFX30S47-G1 3RK1 903-3AE00 Terminal module for fail-safe power modules PM-E F; interrupted AUX busbar to next potential group on left; terminal connection to AUX1 potential Terminal module for power module PM-D with protective cover Terminal module SIGUARD PM-D F 1.2 for potential group, supply voltage U1 and U2, sensor connector Terminal module SIGUARD PM-D F 1.2 for potential subgroup, sensor connector Terminal module SIGUARD PM-D F 3.4 for potential group, supply voltage U2 Terminal module SIGUARD PM-D F 3.4 for potential subgroup, supply voltage U2 Terminal module SIGUARD PM-D F 5 for contact multiplier Terminal module for connection module PM-X connection unit for power supply relay Terminal module for fail-safe power modules PM-D F; AUX busbar to next potential group on left; no terminal connection to AUX1 potential Terminal module for F-CM; with U1 loop Terminal module for PM-D F X1; for potential group; no U1 supply voltage from left TM-PFX30S47-G0 3RK1 903-3AE10 R = Redundant I/O: T = Type discontinued: T TM Terminal module for electronic modules; AUX busbar to next potential group on left; terminal connection to AUX1 potential TM-E15x26-A1 Properties: W = Module wizard: C = CiR support: Properties C R Terminal module for PM-D F X1; for potential group; U1 supply voltage from left X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; X = Supported A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 12 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version Short Description W Motor Starter DS1e-x 0.3 - 3 A; direct starter; mechanical switching; electronic overload protection; no fuse protection up to 1.1 KW/400 V; 0.30 A to 3.00 A. Options: brake control module, control module; High Feature DS1e-x 0.3 - 3 A High Feature 3RK1 301-0AB10-0AA2 DS1e-x 0.3 - 3 A High Feature 3RK1 301-0AB10-0AA3 DS1e-x 0.3 - 3 A; direct starter; mechanical switching; electronic overload protection; no fuse protection up to 1.1 KW/400V; 0.30 A to 3.00 A. Options: brake control module, control module; switch ES; High Feature X DS1e-x 0.3 - 3 A High Feature 3RK1 301-0AB10-0AA4 DS1e-x 0.3 - 3 A; direct starter; mechanical switching; electronic overload protection; no fuse protection; to 1.1 KW/400 V; 0.30 A to 3.00 A. Options: brake control module, control module; switch ES; High Feature; programmable power switch message X DS1e-x 2.4 - 8 A High Feature 3RK1 301-0BB10-0AA2 DS1e-x 2.4 - 8 A; direct starter; mechanical switching; electronic overload protection; no fuse protection up to 3.0 KW/400 V; 2.40 A to 8.00 A. Options: brake control module, control module; High Feature X DS1e-x 2.4 - 8 A High Feature 3RK1 301-0BB10-0AA3 DS1e-x 2.4 A to 8 A; direct starter; mechanical switching; electronic overload protection; no fuse protection up to 3.0 KW/400 V; 2.40 A to 8.00 A. Options: brake control module, control module; High Feature X DS1e-x 2.4 - 8 A High Feature 3RK1 301-0BB10-0AA4 DS1e-x 2.4 - 8 A; direct starter; mechanical switching; electronic overload protection; no fuse protection; to 3.0 KW/400 V; 2.40 A to 8.00 A. Options: brake control module, control module; switch ES; High Feature; programmable power switch message X DS1e-x 2.4 - 16 A High Feature 3RK1 301-0CB10-0AA2 X DS1e-x 2.4 - 16 A High Feature 3RK1 301-0CB10-0AA3 DS1e-x 2.4 - 16 A High Feature 3RK1 301-0CB10-0AA4 DS1e-x 2.4 - 16 A; direct starter; mechanical switching; electronic overload protection; no fuse protection; to 7.5 KW/400 V; 2.40 A to 16 A. Options: brake control module, control module; switch ES; High Feature DS1e-x 2.4 - 16 A; direct starter; mechanical switching; electronic overload protection; no fuse protection; to 7.5 KW/400 V; 2.40 A to 16 A. Options: brake control module, control module; switch ES; High Feature DS1e-x 2.4 - 16 A; direct starter; mechanical switching; electronic overload protection; no fuse protection; to 7.5 KW/400 V; 2.40 A to 16 A. Options: brake control module, control module; switch ES; High Feature; programmable power switch message DSS1e-x 0.3 - 3 A High Feature 3RK1 301-0AB20-0AA2 DSS1e-x 0.3 - 3 A; direct soft starter; mechanical switching; electronic overload protection; no fuse protection up; to 1.1 KW/400 V; 0.30 A to 3.00 A. Options: brake control module, control module; switch ES; High Feature X DSS1e-x 0.3 - 3 A High Feature 3RK1 301-0AB20-0AA3 DSS1e-x 0.3 - 3 A; direct soft starter; mechanical switching; electronic overload protection; no fuse protection up; to 1.1 KW/400 V; 0.30 A to 3.00 A. Options: brake control module, control module; switch ES; High Feature X DSS1e-x 0.3 - 3 A High Feature 3RK1 301-0AB20-0AA4 DSS1e-x 0.3 - 3 A; direct starter; mechanical switching; electronic overload protection; no fuse protection; to 1.1 KW/400 V; 0.30 A to 3.00 A. Options: brake control module, control module; switch ES; High Feature X Properties: W = Module wizard: C = CiR support: R = Redundant I/O: T = Type discontinued: Properties C R X T 05/04 05/04 05/04 X X 05/04 X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; X = Supported A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 13 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version Short Description W Motor Starter DSS1e-x 2.4 - 8 A; direct starter; mechanical switching; electronic overload protection; no fuse protection; to 3.0 KW/400 V; 2..40 A to 8.00 A; Option: brake control module, control module; High Feature Properties C R T DSS1e-x 2.4 - 8 A High Feature 3RK1 301-0BB20-0AA2 DSS1e-x 2.4 - 8 A High Feature 3RK1 301-0BB20-0AA3 DSS1e-x 2.4 - 8 A; direct starter; mechanical switching; electronic overload protection; no fuse protection; to 3.0 KW/400 V; 2.40 A to 8.00 A; Option: brake control module, control module; switch ES; High Feature X DSS1e-x 2.4 - 8 A High Feature 3RK1 301-0BB20-0AA4 DSS1e-x 2.4 - 8 A; direct starter; mechanical switching; electronic overload protection; no fuse protection; to 3.0 KW/400 V; 2.40 A to 8.00 A. Options: brake control module, control module; switch ES; High Feature X DSS1e-x 2.4 - 16 A High 3RK1 301-0CB20-0AA2 Feature DSS1e-x 2.4 - 16 A; direct starter; mechanical switching; electronic overload protection; no fuse protection up to 7.5 KW/400 V; 2.40 A to 16 A. Options: brake control module, control module; High Feature X 05/04 DSS1e-x 2.4 - 16 A High 3RK1 301-0CB20-0AA3 Feature DSS1e-x 2.4 - 16 A; direct starter; mechanical switching; electronic overload protection; no fuse protection up to 7.5 KW/400 V; 2.40 A to 16 A. Options: brake control module, control module; High Feature DSS1e-x 2.4 - 16 A; direct starter; mechanical switching; electronic overload protection; no fuse protection; to 7.5 KW/400 V; 2.40 A to 16 A. Options: brake control module, control module; switch ES; High Feature 05/04 DSS1e-x 2.4 - 16 A High 3RK1 301-0CB20-0AA4 Feature X RS1e-x (0.3 - 3A) High Feature 3RK1 301-0AB10-1AA2 RS1e-x (0.3 - 3A) High Feature; reversing starter; mechanical switching; electronic overload protection; no fuse protection; to 1.1 KW/400 V; 0.30 A to 3.00 A. Options: brake control module, Control Module; High Feature X RS1e-x (0.3 - 3A) High Feature 3RK1 301-0AB10-1AA3 RS1e-x (0.3 - 3A) High Feature; reversing starter; mechanical switching; electronic overload protection; no fuse protection; to 1.1 KW/400 V; 0.30 A to 3.00 A. Options: brake control module, Control Module; High Feature X RS1e-x (0.3 - 3A) High Feature 3RK1 301-0AB10-1AA4 X RS1e-x (2.4 - 8A) High Feature 3RK1 301-0BB10-1AA2 RS1e-x (0.3 - 3A) High Feature; reversing starter; mechanical switching; electronic overload protection; no fuse protection; to 1.1 KW/400 V; 0.30 A to 3.00 A. Options: brake control module, control module; switch ES; High Feature; programmable power switch message RS1e-x (2.4 - 8A) High Feature; reversing starter; mechanical switching; electronic overload protection; no fuse protection; to 3.0 KW/400 V; 2.40 A to 8.00 A. Options: brake control module, control module; High Feature RS1e-x (2.4 - 8A) High Feature 3RK1 301-0BB10-1AA3 RS1e-x (2.4 - 8A) High Feature; reversing starter; mechanical switching; electronic overload protection; no fuse protection; to 3.0 KW/400 V; 2.40 A to 8.00 A. Options: brake control module, control module; High Feature X RS1e-x (2.4 - 8A) High Feature 3RK1 301-0BB10-1AA4 RS1e-x (2.4 - 8A) High Feature; reversing starter; mechanical switching; electronic overload protection; no fuse protection; to 3.0 KW/400 V; 2.40 A to 8.00 A. Options: brake control module, control module; switch ES; High Feature; programmable power switch message X Properties: W = Module wizard: C = CiR support: R = Redundant I/O: T = Type discontinued: X 05/04 05/04 X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; X = Supported A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 14 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB RS1e-x (2.4 - 16A) High 3RK1 301-0CB10-1AA2 Feature FW Version Short Description W Motor Starter RS1e-x (2.4 - 16A) High Feature; reversing starter; mechanical switching; electronic overload protection; no fuse protection; to 7.5 KW/400 V; 2.40 A to 16 A. Options: brake control module, control module; High Feature X RS1e-x (2.4 - 16A) High 3RK1 301-0CB10-1AA3 Feature RS1e-x (2.4 - 16A) High Feature; reversing starter; mechanical switching; electronic overload protection; no fuse protection; to 7.5 KW/400 V; 2.40 A to 16 A. Options: brake control module, control module; High Feature X RS1e-x (2.4 - 16A) High 3RK1 301-0CB10-1AA4 Feature RS1e-x (2.4 - 16A) High Feature; reversing starter; mechanical switching; electronic overload protection; no fuse protection; to 7.5 KW/400 V; 2.40 A to 16 A. Options: brake control module, control module; switch ES; High Feature; programmable power switch message F-Motor starter X F-DS1e-x 0.3 - 3 A High 3RK1 301-0AB13-0AA2 Feature F-DS1e-x 0.3 - 3 A High Feature; safe direct starter; mechanical switching; electronic overload protection; no fuse protection; to 1.1 KW/400 V; 0.30 A to 3.00 A. Options: brake control module, control module; High Feature; for PM-D F PROFIsafe X F-DS1e-x 0.3 - 3 A High 3RK1 301-0AB13-0AA4 Feature F-DS1e-x 0.3 - 3 A High Feature; safe direct starter; mechanical switching; electronic overload protection; no fuse protection; to 1.1 KW/400 V; 0.30 A to 3.00 A. Options: brake control module, control module; High Feature; for PM-D F PROFIsafe; programmable power switch message F-DS1e-x 2.4 - 8 A High Feature; safe direct starter; mechanical switching; electronic overload protection; no fuse protection; to 3.0 KW/400 V; 2.40 A to 8.00 A. Options: brake control module, control module; High Feature; for PM-D F PROFIsafe X F-DS1e-x 2.4 - 8 A High 3RK1 301-0BB13-0AA2 Feature F-DS1e-x 2.4 - 8 A High 3RK1 301-0BB13-0AA4 Feature F-DS1e-x 2.4 - 16 A High 3RK1 301-0CB13-0AA2 Feature Properties: W = Module wizard: C = CiR support: R = Redundant I/O: T = Type discontinued: Properties C R T 05/04 X F-DS1e-x 2.4 - 8 A High Feature; safe direct starter; X mechanical switching; electronic overload protection; no fuse protection; to 3.0 KW/400 V; 2.40 A to 8.00 A. Options: brake control module, control module; High Feature; for PM-D F PROFIsafe; programmable power switch message F-DS1e-x 2.4 - 16 A High Feature; safer direct starter; X mechanical switching; electronic overload protection; no fuse protection; to 7.5 KW/400 V; 2.40 A to 16 A. Options: brake control module, control module; High Feature; for PM-D F PROFIsafe X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; X = Supported A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 15 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB F-DS1e-x 2.4 - 16 A High 3RK1 301-0CB13-0AA4 Feature FW Version Short Description W F-Motor starter F-DS1e-x 2.4 - 16 A High Feature; safe direct starter; mechanical switching; electronic overload protection; no fuse protection; to 7.5 KW/400 V; 2.40 A to 16 A. Options: brake control module, control module; High Feature; for PM-D F PROFIsafe; programmable power switch message F-RS1e-x 0.3 - 3 A High Feature; safe reversing starter; mechanical switching; electronic overload protection; no fuse protection; to 1.1 KW/400 V; 0.30 A to 3.00 A; Option: brake control module, control module; High Feature; for PM-D F PROFIsafe X F-RS1e-x 0.3 - 3 A High 3RK1 301-0AB13-1AA4 Feature F-RS1e-x 0.3 - 3 A High Feature; safe reversing starter; mechanical switching; electronic overload protection; no fuse protection; to 1.1 KW/400 V; 0.30 A to 3.00 A. Options: brake control module, control module; High Feature; for PM-D F PROFIsafe; programmable power switch message X F-RS1e-x 2.4 - 8 A High 3RK1 301-0BB13-1AA2 Feature F-RS1e-x 2.4 - 8 A High Feature; safe reversing starter; mechanical switching; electronic overload protection; no fuse protection, to 3.0 KW/400 V; 2.40 A to 8.00 A. Options: brake control module, control module; High Feature; for PM-D F PROFIsafe X F-RS1e-x 2.4 - 8 A High 3RK1 301-0BB13-1AA4 Feature F-RS1e-x 2.4 - 8 A High Feature; safe reversing starter; mechanical switching; electronic overload protection; no fuse protection; to 3.0 KW/400 V; 2.40 A to 8.00 A. Options: brake control module, control module; High Feature; for PM-D F PROFIsafe; programmable power switch message X F-RS1e-x 2.4 - 16 A High 3RK1 301-0CB13-1AA2 Feature F-RS1e-x 2.4 - 16 A High Feature; safe reversing starter; mechanical switching; electronic overload protection; no fuse protection; to 7.5 KW/400 V; 2.40 A to 16 A. Options: brake control module, control module; High Feature; for PM-D F PROFIsafe X F-RS1e-x 2.4 - 16 A High 3RK1 301-0CB13-1AA4 Feature F-RS1e-x 2.4 - 16 A High Feature; safe reversing starter; mechanical switching; electronic overload protection; no fuse protection; to 7.5 KW/400 V; 2.40 A to 16 A. Options: brake control module, control module; High Feature; for PM-D F PROFIsafe; programmable power switch message X T = Type discontinued: T X F-RS1e-x 0.3 - 3 A High 3RK1 301-0AB13-1AA2 Feature Properties: W = Module wizard: C = CiR support: Properties C R X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; at specified date Page 16 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version Short Description W Motor Starter Accessories xB3 DC24V/4A; brake control module 24 VDC / 4 A, 2DI 24 VDC Local Control xB4 DC500V/0.7A; brake control module 500 VC / 0.7A, 2DI 24 VDC Local Control TM Motor Starter Terminal module for DS1e-x and DSS1e-x motor starter, power supply bus, with caps xB3 DC24V/4A 3RK1 903-0CE00 xB4 DC500V/0.7A 3RK1 903-0CF00 TM-DS65-S32-01 FS L 3RK1 903-0AK00 TM-DS65-S31-01 S 3RK1 903-0AK10 Terminal module for DS1e-x and DSS1e-x motor starter, looped power supply bus TM-RS130-S32-01 FS L 3RK1 903-0AL00 Terminal module for RS1e-x motor starter, power supply bus, with caps TM-RS130-S31-01 S TM-FDS65-S32-01 FS L 3RK1 903-0AL10 Terminal module for RS1e-x motor starter, with energy bus pass-through Terminal module for fail-safe DS1e-x motor starter, power supply bus, with caps TM-FDS65-S32-01 FS L 3RK1 903-3AC00 Terminal module for fail-safe DS1e-x motor starter, power supply bus, with caps TM-FDS65-S31-01 S TM-FDS65-S31-01 S TM-FRS130-S32-01 FS L 3RK1 903-0AC10 Terminal module for fail-safe DS1e-x motor starter, looped power supply bus Terminal module for fail-safe DS1e-x motor starter, looped power supply bus Terminal module for fail-safe RS1e-x motor starter, power supply bus, with caps TM-FRS130-S32-01 FS L 3RK1 903-3AD00 Terminal module for fail-safe RS1e-x motor starter, power supply bus, with caps TM-FRS130-S31-01 S TM-FRS130-S31-01 S TM-xB215 S24-01 3RK1 903-0AD10 Terminal module for fail-safe RS1e-x motor starter, looped power supply bus Terminal module for fail-safe RS1e-x motor starter, looped power supply bus Terminal module for brake control module xB3, xB4 Properties: W = Module wizard: C = CiR support: R = Redundant I/O: T = Type discontinued: 3RK1 903-0AC00 3RK1 903-3AC10 3RK1 903-0AD00 3RK1 903-3AD10 3RK1 903-0AG01 Properties C R T X X X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; X = Supported A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 17 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version Short Description W Properties C R T ET 200X ET 200X EM 144 AI 2x U 6ES7 144-1FB31-0XB0 ET 200X EM 144 AI2x I 6ES7 144-1GB31-0XB0 ET 200X EM 144 AI 2x I 6ES7 144-1GB41-0XB0 ET 200X EM 144 AI 2x RTD 6ES7 144-1JB31-0XB0 ET 200X EM 145 AO 2x 6ES7 145-1FB31-0XB0 U ET 200X EM 145 AO 2x I 6ES7 145-1GB31-0XB0 ET 200X BM 141 DI 8xDC24V 6ES7 141-1BF11-0XB0 ET 200X BM 142 DO 4xDC24V/2A 6ES7 142-1BD21-0XB0 ET 200X EM 141 DI 8xDC24V ET 200X EM 141 DI 8xDC24V 6ES7 141-1BF30-0XA0 ET 200X EM 142 DO 4xDC24V/2A ET 200X EM 142 DO 8xDC24V/1.3A ET 200X PM 148 6ES7 141-1BF40-0XA0 6ES7 142-1BD40-0XB0 6ES7 142-1BF30-0XA0 6ES7 148-1CA00-0XB0 ET 200X EM 148-P; DO 6ES7 148-1EH01-0XA0 16xP/CPV10 ET 200X EM 148-P; DO 6ES7 148-1EH11-0XA0 16xP/CPV14 Properties: W = Module wizard: C = CiR support: R = Redundant I/O: T = Type discontinued: AI Expansion module AI 2x U (+/-10V), Diagnostics X Expansion module AI 2x I (+/-20mA, 4-20mA, 4-wire measuring transducer), Diagnostics Expansion module AI 2x I (4-20mA, 2-wire measuring transducer), Diagnostics Expansion module AI 2x RTD (Pt100), Diagnostics X AO Expansion module AO 2x U (+/-10V), Diagnostics X Expansion module AO 2x I (+/-20mA, 4-20mA), Diagnostics BM_DI ET 200X BM 141 DI 8xDC24V; Basic module ET 200X- DI 8xDC24V, expandable with analog EMs BM_DO ET 200X BM 142 4DO 24 VDC/2A; basic module ET 200X, 4DO 24 VDC/2A, expandable with analog EMs DI ET 200X EM 141 DI 8xDC24V; expansion module DI 8xDC24V ET 200X EM 141 DI 8xDC24V; expansion module ET 200X DI 8xDC24V DO ET 200X EM 142 4DO 24 VDC/2A; expansion module 4DO 24 VDC/2A, diagnostics ET 200X EM 142 8DO 24 VDC/1.3A; expansion module ET 200X 8DO 24 VDC/1.3A PM SIMATIC DP, power module PM 148 FOR ET 200X, 4 DO 24 VDC/2A with load voltage supply, diagnostics by channels Valve ET 200X EM 148-P; DO 16xP/CPV10; Expansion module DO16xP (coupling module for valve block CPV10) ET 200X EM 148-P; DO 16xP/CPV14; Expansion module DO16xP (coupling module for valve block CPV14) X X X X X 05/03 X X 11/02 X X X X X X X X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; X = Supported A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 18 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version Short Description W Properties C R T ET 200pro ET 200PRO EM 144 AI 4 x U ET 200PRO EM 144 AI 4 x I ET 200PRO EM 144 AI 4 x RTD 6ES7 144-4FF00-0AB0 6ES7 144-4GF00-0AB0 6ES7 144-4JF00-0AB0 AI Analog input module 4 AI U; 10V, 5V, 1...5V, 0...10V Analog input module 4 AI I; 20mA, 0...20mA, 4...20mA Analog input module 4 AI RTD; ET 200PRO EM 141 DI 8xDC 24V 6ES7 141-4BF00-0AB0 AO Analog output module 4 AO U; 10V, 1...5V, 0...10V Analog output module 4 AO I; 20mA, 0...20mA, 4...20mA DI Digital input module 8 DI DC24V; High Feature ET 200PRO EM 142 DO 4xDC 24V/2A 6ES7 142-4BD00-0AB0 DO Digital output module 4 DO DC24V 2A; High Feature ET 200PRO EM 148 F-DI 8/16xDC 24V 6ES7 148-4FA00-0AB0 ET 200PRO EM 148 F-DI 4/8xDC 24V F-DO 4xDC24V/2A 6ES7 148-4FC00-0AB0 ET 200PRO IM154-2 DP HF 6ES7 154-2AA00-0AB0 ET 200PRO IM154-2 DP HF 6ES7 154-2AA01-0AB0 ET 200PRO PM-E DC24V 6ES7 148-4CA00-0AA0 CM IM DP ECOFAST CM IM DP Direct CM IM DP M12 / 7/8" CM PM ECOFAST CM PM Direct CM PM 7/8" CM IO 4 x M12 CM IO 8 x M12 CM 12xM12 for 4/8 F-DI/4 F-DO CM 16xM12 for 8/16 F-DI 6ES7 194-4AA00-0AA0 6ES7 194-4AC00-0AA0 6ES7 194-4AD00-0AA0 6ES7 194-4BA00-0AA0 6ES7 194-4BC00-0AA0 6ES7 194-4BD00-0AA0 6ES7 194-4CA00-0AA0 6ES7 194-4CB00-0AA0 6ES7 194-4DC00-0AA0 ET 200PRO EM 145 AO 4 x U ET 200PRO EM 145 AO 4 x I 6ES7 145-4FF00-0AB0 6ES7 145-4GF00-0AB0 6ES7 194-4DD00-0AA0 F-DI Digital input module DI 8/16xDC24V, PROFIsafe V2, safety-oriented F-DI/DO Digital I/O module DI 4/8 / 4DO 24 VDC/2A, PROFIsafe V2, safety-oriented IM SIMATIC DP, PROFIBUS DP INTERFACE MODULE IM154-2 HIGH FEATURE FOR ET 200PRO INCLUDING TERMINATING MODULE SIMATIC DP, PROFIBUS DP INTERFACE MODULE IM154-2 HIGH FEATURE FOR ET 200PRO INCLUDING TERMINATING MODULE PM PM-E DC24V X X X X X X X X X X X X X X Connection modules Connection module CM for IM ECOFAST CU DP Connection module CM for IM DP Direct Connection module CM for IM DP M12 / 7/8" Connection module CM for PM ECOFAST Connection module CM for PM direct Connection module CM for PM 7/8" Connection module CM for IO 4xM12 Connection module CM for IO 8xM12 Connection module CM for F-DI/DO-EM 4/8 F-DI/4 F-DO DC24V/2A Connection module CM for F-DI EM 8/16 F-DI DC24V/2A Repeater Diagnostic Repeater 6ES7 972-0AB00-0XA0 Diagnostic Repeater 6ES7 972-0AB01-0XA0 Properties: W = Module wizard: C = CiR support: R = Redundant I/O: T = Type discontinued: Diagnostic Repeater Diagnostic repeater for wire diagnostics on the PROFIBUS DP (RS485), IP20, up to 12 Mbit/s IP20, up to 12 Mbit/s, DPV0 slave Diagnostic repeater for wire diagnostics on PROFIBUS-DP (RS485), IP20, up to 12 Mbit/s, DPV1 slave X X X X 02/03 X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; X = Supported A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 19 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version Short Description W Properties C R T Network Components Ethernet SIMATIC NET, OLM F. INDUSTRIAL ETHERNET, OPTICAL LINK MODULE WITH 3 ITP- A. 2 FOC PORTS, REDUNDANT VOLTAGE SUPPLY, sIGNALING CONTACT IE OLM 6GK1 102-4AA00 IE OSM TP22 6GK1 105-2AE00 Industrial Ethernet OSM TP22 Optical Switch Module, 2 FOC ports 100 Mbit/s, 2 RJ45 ports 10/100 Mbit/s and 4 digital inputs; redundant 24 VDC supply, signaling contact; network management IE OSM ITP62 6GK1 105-2AA10 SIMATIC NET, OSM TP62 OPTICAL SWITCH MODULE WITH 2 FOC PORTS 100 MBIT/S U. 6 RJ45-PORTS 10/100 MBIT/S, REDUNDANT 24 VDC POWER SUPPLY, SIGNALING CONTACT, INTEGRATED REDUNDANCY MANAGER IE OSM TP62 6GK1 105-2AB10 SIMATIC NET, OSM ITP62 OPTICAL SWITCH MODULE with 2 FOC PORTS 100 MBIT/S AND 6 ITP PORTS 10/100 MBIT/S, REDUNDANT 24 VDC POWER SUPPLY, SIGNALING CONTACT, INTEGRATED REDUNDANCY MANAGER IE OSM ITP62-LD 6GK1 105-2AC10 SIMATIC NET, OSM ITP62-LD OPTICAL SWITCH MODULE WITH 2 FOC PORTS 100 MBIT/S LONG DISTANCE (FOC up to 18 KM) AND 6 ITP PORTS 10/100 MBIT/S, REDUNDANT 24 VDC POWER SUPPLY, SIGNALING CONTACT, INTEGRATED REDUNDANCY MANAGER IE OSM ITP53 6GK1 105-2AD10 SIMATIC NET, OSM ITP53 OPTICAL SWITCH MODULE WITH 3 FOC PORTS 100 MBIT/S U. 5 ITP PORTS 10/100 MBIT/S, REDUNDANT 24 VDC SUPPLY, SIGNALING CONTACT, INTEGRATED REDUNDANCY MANAGER IE ESM ITP80 6GK1 105-3AA10 IE ESM TP80 6GK1 105-3AB10 IE OSM BC08 6GK1 105-4AA00 SIMATIC NET, ESM ITP80 ELECTRICAL SWITCH MODULE WITH 8 ITP-PORTS 10/100 MBIT/S, REDUNDANT 24 VDC SUPPLY, SIGNALING CONTACT, INTEGRATED REDUNDANCY MANAGER SIMATIC NET, ESM TP80 ELECTRICAL SWITCH MODULE WITH 8 RJ45 PORTS 10/100 MBIT/S, REDUNDANT 24 VDC SUPPLY, SIGNALING CONTACT, INTEGRATED REDUNDANCY MANAGER Industrial Ethernet OSM BC08 Optical Switch Module, 8 FOC ports 100 Mbit/s and 8 digital inputs; redundan 24 VDC supply, signaling contact; network management SCALANCE X414-3E 6GK5 414-3FC00-2AA2 SCALANCE X408-2 6GK5 408-2FD00-2AA2 Properties: W = Module wizard: C = CiR support: R = Redundant I/O: T = Type discontinued: 10/05 MODULAR INDUSTRIAL ETHERNET SWITCH, 2 X 10/100/1000 MBIT/S AND 12 X 10/100 MBIT/S RJ45 PORTS, 1 X GIGAGBIT AND 2 X 100 MBIT MEDIA MODULE SLOTS, EXTENDED INTERFACE, INTEGRATED REDUNDANCY MANAGER, OFFICE FEATURES (RSTP, VLAN,..) NETWORK MANAGEMENT, C-PLUG IN SCOPE OF DELIVERY MODULAR INDUSTRIAL ETHERNET SWITCH, 4 X 10/100/1000 MBIT/S AND 4 X 10/100 MBIT/S RJ45 PORTS, 2 X GIGAGBIT/FAST ETHERNET MEDIA MODULE SLOTS, INTEGRATED REDUNDANCY MANAGER, OFFICE FEATURES (RSTP, VLAN,..) NETWORK MANAGEMENT, C-PLUG IN SCOPE OF DELIVERY X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; X = Supported A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 20 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version Short Description W 6GK5 491-2AB00-8AA2 Media module MM492-2 6GK5 492-2AL00-8AA2 1000Base-SX Ethernet media module for SCALENCE X414-3E Extender module EM495-8 Extender module EM496-4 IE Media converter SCALANCE X101-1 6GK5 495-8BA00-8AA2 IE Media converter SCALANCE X101-1LD 6GK5 101-1BC00-2AA3 SCALANCE X208 6GK5 208-0BA00-2AA3 SCALANCE X204-2 6GK5 204-2BB03-2AA3 Extender module EM495-8 with 8 x 10/100 Mbit/s TP Ports Extender module EM496-4 with 4 slots for 100 Mbit/s media modules Industrial Ethernet media converter SCALANCE X101 1 for converting RJ45 TP to Multimode FOC (BFOC) with 100 Mbit/s; 1 x 10/100 Mbit/s RJ45 port and 1 x 100 Mbit/s Multimode BFOC; redundant 24 VDC supply, signaling contact Industrial Ethernet Media converter SCALANCE X101 1LD for converting RJ45 TP to Single mode FOC (BFOC) with 100 Mbit/s; 1 x 10/100 Mbit/s RJ45 port und 1 x 100 Mbit/s Single mode BFOC; redundant 24 VDC supply and signaling contact Managed Industrial Ethernet Switch with 8 RJ45 Ports 10/100 MBit/s for the set up of the Industrial Ethernet line- star-, or ring topologies Managed Industrial Ethernet Switch with 4 RJ45 Ports 10/100 MBit/s and 2 BFOC Ports for the set up of the Industrial Ethernet line- star-, or ring topologies SCALANCE X204 IRT 6GK5 204-0BA00-2BA3 SCALANCE X202-2 IRT 6GK5202-2BB00-2BA3 SCALANCE X206-1LD 6GK5206-1BC10-2AA3 SCALANCE X212-2 6GK5212-2BB00-2AA3 SCALANCE X212-2LD 6GK5212-2BC00-2AA3 SCALANCE X216 6GK5216-0BA00-2AA3 SCALANCE X224 6GK5224-0BA00-2AA3 SCALANCE X202-2P IRT 6GK5 202-2BH00-2BA3 SCALANCE X201-3P IRT 6GK5 201-3BH00-2BA3 SCALANCE X200-4P IRT SCALANCE X308-2 6GK5 200-4AH00-2BA3 6GK5308-2FL00-2AA3 SCALANCE X308-2LD 6GK5308-2FM00-2AA3 SCALANCE X310 6GK5310-0FA00-2AA3 Properties: W = Module wizard: C = CiR support: R = Redundant I/O: T = Type discontinued: 6GK5 101-1BB00-2AA3 T Ethernet 100Base-FX Ethernet media module for SCALENCE X414-3E Media module MM491-2 6GK5 496-4MA00-8AA2 Properties C R Managed Industrial Ethernet IRT Switch with 4 x RJ45 ports 10/100 MBit/s for the set up of the Industrial Ethernet line- star-, or ring topologies Managed Industrial Ethernet Switch with 2 x RJ45 ports 10/100 MBit/s and two BFOC ports for the set up of the Industrial Ethernet line- star-, or ring topologies Managed Industrial Ethernet Switch, 6 X 10/100 Mbit/s RJ45 ports 1 X 100 Mbit/s Single mode BFOC SCALANCE X212-2, Managed Industrial Ethernet Switch, 12 X 10/100 Mbit/s RJ45 ports 2 X 100 Mbit/s Multimode BFOC SCALANCE X212-2LD, Managed Industrial Ethernet Switch, 12 X 10/100 MBIT/S RJ45 ports 2 X 100 MBIT/S Single mode BFOC Managed Industrial Ethernet Switch, 16 X 10/100 Mbit/s RJ45 ports Managed Industrial Ethernet Switch, 24 X 10/100 MBIT/S RJ45 ports SCALANCE X202-2P IRT 2 x 10/100 Mbit/s RJ45 ports, 2 x 100 Mbit/s POF/PCF SC RJ ports SCALANCE X201-3P IRT 1 x 10/100 Mbit/s RJ45 port, 3 x 100 Mbit/s POF/PCF SC RJ ports SCALANCE X200-4P IRT 4 x 100 Mbit/s POF/PCF SC RJ ports Managed Plus Industrial Ethernet Switch, 2 X 1000 Mbit/s MM SC 1 X 10/100/1000 Mbit/s and 7 X 10/100 Mbit/s RJ45 ports Managed Plus Industrial Ethernet Switch, 2 X 1000 Mbit/s SM SC 1 X 10/100/1000 Mbit/s and 7 X 10/100 Mbit/s RJ45 ports Managed Plus Industrial Ethernet Switch, 3 X 10/100/1000 Mbit/s and 7 X 10/100 Mbit/s RJ45 ports X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; X = Supported A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 21 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version Short Description W 6GK5 788-1ST00-2AA6 SCALANCE W7882PRO 6GK5788-2ST00-2AA6 SCALANCE W788-2PRO Industrial WLAN DUAL ACCESS POINT SCALANCE W7461PRO 6GK5 746-1ST00-2AA6 SCALANCE W746-1 PRO Industrial WLAN CLIENT MODULE SCALANCE W7441PRO 6GK5 744-1ST00-2AA6 SCALANCE W744-1 PRO Industrial WLAN CLIENT MODULE SCALANCE S602 6GK5 602-0BA00-2AA3 SCALANCE S602 Industrial Security Module, access security by means of Stateful Inspection Firewall SCALANCE S612 6GK5 612-0BA00-2AA3 SCALANCE S612 Industrial Security Module, access security by means of Stateful Inspection Firewall for up to 32 devices per VPN tunnel (simultaneously up to 64 VPN tunnels) SCALANCE S613 6GK5 613-0BA00-2AA3 SCALANCE S613 Industrial Security Module, access security by means of Stateful Inspection Firewall for up to 64 devices per VPN tunnel (simultaneously up to 128 VPN tunnels); suitable for extended temperature range from -20 C to +70 C R = Redundant I/O: T = Type discontinued: T Ethernet SCALANCE W788-1PRO Industrial WLAN ACCESS POINT SCALANCE W7881PRO Properties: W = Module wizard: C = CiR support: Properties C R X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; X = Supported A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 22 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version Short Description W Properties C R T PC Controller CPU 416-2 PCI as expansion card for PCs; supports constant bus cycle time and isochronous mode; routing; firmware V3.4 CPU 416-2 PCI as expansion card for PCs; supports constant bus cycle time and isochronous mode; routing; firmware V4.0 CP Ethernet SIMATIC NET CP 1613 Industrial Ethernet, ISO, TCP/IP, S7 Connections, PG functions, PCI-Bus SIMATIC NET CP 1613 Industrial Ethernet, ISO, TCP/IP, S7 Connections, PG functions, PCI bus SIMATIC NET CP 1613 Industrial Ethernet, ISO, TCP/IP, S7 Connections, PG functions, PCI Express bus CP 1512; SIMATIC NET CP1512 Industrial Ethernet, ISO, TCP/IP, S7 Connections, PG functions, PCMCIA, only for use with PCS7 ES ! CPU 416-2 PCI 6ES7 616-2QL00-0AB4 V3.4 CPU 416-2 PCI 6ES7 616-2QL10-0AB4 V4.0 CP 1613 6GK1 161-3AA00 CP 1613 A2 6GK1 161-3AA01 CP 1623 6GK1 162-3AA00 CP 1512 6GK1 151-2AA00 CP 1612 6GK1 161-2AA00 CP 1612; SIMATIC NET CP 1612 Industrial Ethernet, ISO, TCP/IP, S7 Connections, PG functions, PCI-Bus Server adapter network card PCI A5E01605513 Server adapter network card for BCE, replacement part for redundant terminal bus INTEL PCI network adapter for Industrial Ethernet (10/100/1000 Mbit/s), with RJ45 connector Desktop adapter network A5E00718412 card PCI Desktop adapter network card for BCE, replacement part for redundant terminal bus INTEL PCI network adapter for Industrial Ethernet (10/100/1000 Mbit/s), with RJ45 connector Server adapter network card PCI Express A5E01579487 Server adapter network card for BCE, replacement part for redundant terminal bus INTEL PCI Express network adapter for Industrial Ethernet (10/100/1000 Mbit/s), with RJ45 connector Desktop adapter network A5E01579552 card PCI Express Desktop adapter network card for BCE, replacement part for redundant terminal bus INTEL PCI Express network adapter for Industrial Ethernet (10/100/1000 Mbit/s), with RJ45 connector CP 5611 6GK1 561-1AA00 CP 5611 A2 6GK1 561-1AA01 CP 5613 6GK1 561-3AA00 CP 5613 A2 6GK1 561-3AA01 CP 7515 6GK1 751-5AA00 Properties: W = Module wizard: C = CiR support: R = Redundant I/O: T = Type discontinued: CP-Profibus SIMATIC NET CP 5611 PROFIBUS, PCI bus, only for use with SIMATIC PDM! SIMATIC NET CP 5611 A2 PROFIBUS, PCI Bus V2.2, only for use with SIMATIC PDM! SIMATIC NET CP 5613 PROFIBUS, PCI Bus, DP master for DP-V0 /-V1 SIMATIC NET CP 5613 A2 PROFIBUS, PCI Bus V2.2, DP master for DP-V0 /-V1 CP - IWLAN SIMATIC NET CP 7515 Industrial WLAN PCMCIA X X X 07/05 X X 01/06 X X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; X = Supported A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 23 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version Short Description W Properties C R T PCS 7 2XV9 450-1AR13 2XV9 450-1AR14 DCFRS for Windows 95/NT, DCF 77 receiver for time synchronization within Europe, incl. mounting kit 2XV9 450-1AR24 SICLOCK TM time transmitter, complete package GPS, 24 VDC to 110 VDC, for synchronizing nodes on Industrial Ethernet 2XV9 450-1AR25 SICLOCK TM time transmitter, complete GPS package GPS, 90V DC/AC to 240 VDC/AC, for synchronizing nodes on Industrial Ethernet 2XV9 450-1AR26 SICLOCK TM time transmitter, complete package DCF77, 24 VDC to 110 VDC, for synchronizing nodes on Industrial Ethernet 2XV9 450-1AR27 SICLOCK TM time transmitter, DCF77, 90VAC/DC to 240 VDC/AC, for synchronizing nodes on Industrial Ethernet 3P7217B00APF01 MicroLaser 170, high-speed laser printer (monochrome) with Centronics interface and optional network adapter, 12 MB RAM 3P74C4B00APQ01 MicroLaser C4, high-resolution color laser printer, with network capability, 24 MB RAM, with network adapter GNC: Signal module, PCI card for installation in OS or ES stations (horn) 6DS1 916-8RR Properties: W = Module wizard: C = CiR support: R = Redundant I/O: T = Type discontinued: Partner Modules WinGPS for Windows 95/NT, GPS receiver for worldwide time synchronization, incl. mounting kit 6DS1 916-8AA Signal module, ISA card for installation in OS or ES stations (horn) 6ES7 652-0XX01-1XC0 External chip card reader, V.24 interface, PS/2 power supply module with 1.8 m cable, operating instructions, software for User Administrator and process control; required for all OS stations 6ES7652-0XX02-1XC0 Smart card reader V2.0, desktop version, USB port 6ES7 652-0XX02-1XE0 6ES7 652-0XX02-1XE1 6ES7 652-0XX03-1XE0 6ES7 652-0XX03-1XE1 G200 MMS Multi-VGA graphic adapter "2 screens" G200 MMS Multi-VGA graphic adapter "4 screens" G450 MMS Multi-VGA graphic adapter "2 screens" G450 MMS Multi-VGA graphic adapter "4 screens" 10/04 10/04 X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; X = Supported A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 24 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version Short Description W Properties C R T S7-300 CP - PtP CP341 RS232, communication processor, RS232 port, reloadable drivers CP341 RS232, communication processor, RS232 port, reloadable drivers. Now with 4 Kbyte message frame length, 115 Kbaud data rate and printer driver CP341-1A 6ES7 341-1AH01-0AE0 CP341-1A 6ES7 341-1AH02-0AE0 CP341-1B 6ES7 341-1BH01-0AE0 CP341-1B 6ES7 341-1BH02-0AE0 CP341-1C 6ES7 341-1CH01-0AE0 CP341-1C 6ES7 341-1CH02-0AE0 CP342-2 AS-I 6GK7 342-2AH00-0XA0 1) CP342-2 AS-I 6GK7 342-2AH01-0XA0 1) CP343-2 AS-i 6GK7 343-2AH00-0XA0 1) FM350-1 COUNTER 6ES7 350-1AH03-0AE0 V1.0.2 FM350-2 COUNTER CP341 TTY, communication processor TTY interface, reloadable drivers CP341 TTY, communication processor TTY interface, reloadable drivers. Now with 4 Kbyte message frame length, 115 Kbaud data rate and printer driver CP341 RS422, com. processor, RS422 port, reloadable drivers CP341 RS422, com. processor, RS422 port, reloadable drivers. Now with 4 Kbyte message frame length, 115 Kbaud data rate and printer driver X M X M X M X M X M X M CP-AS-i SIMATIC NET CP 342-2, for connecting an S7-300 to an AS interface SIMATIC NET CP 342-2, for connecting an S7-300 to an AS interface Basic module for connecting an AS interface. Supports AS-i A/B slaves and AS-i 7.3/7.4 analog slaves M 12/08 12/08 12/08 07/00 M M FM Counter module, single-channel, also for configuration X with active bus modules, supports isochronous mode M 6ES7 350-2AH00-0AE0 Counter module, 8 channels X M FM350-2 COUNTER 6ES7 350-2AH01-0AE0 Counter module, 8 channels X M FM355 C PID Control 6ES7 355-0VH10-0AE0 X M FM355 S PID Control 6ES7 355-1VH10-0AE0 X M FM355-2 C 6ES7 355-2CH00-0AE0 X M FM355-2 S 6ES7 355-2SH00-0AE0 X M PS307 2A PS307 2A PS307 5A PS307 5A PS307 10 A PS307 10 A 6ES7 307-1BA00-0AA0 6ES7 305-1BA80-0AA0 6ES7 307-1EA00-0AA0 6ES7 307-1EA80-0AA0 6ES7 307-1KA00-0AA0 6ES7 307-1KA01-0AA0 Control module, 4 channels (continuous count) 4AI+8DI+4AO, V2.0 Control module, 4 channels (step and pulse mode) 4AI+8DI+8DO, V2.0 FM355-2 C; control module, 4 channels, temperature controller FM355-2 S; control module, 4 channels, temperature controller PS Load power supply 120/230 VAC:24 VDC/2 A Load power supply 120/230 VAC:24 VDC/2 A Load power supply 120/230 VAC:24 VDC/5 A Load power supply 120/230 VAC:24 VDC/5 A Load power supply 120/230 VAC:24 VDC/10 A Load power supply 120/230 VAC:24 VDC/10 A 10/08 04/03 1) Automatic integration in PCS 7 only by means of the "Programming instructions for driver blocks V6.0". New AS-i modules can be used as substitution module in PCS7. Properties: W = Module wizard: C = CiR support: R = Redundant I/O: T = Type discontinued: X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; X = Supported A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 25 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB SM 321 DI 16x24VDC 6ES7 321-1BH01-0AA0 SM 321 DI 16x24VDC 6ES7 321-1BH02-0AA0 SM321 DI 16xDC24V 6ES7 321-1BH10-0AA0 SM321 DI16x24VDC 6ES7 321-1BH50-0AA0 SM321 DI 16xDC24V 6ES7 321-1BH81-0AA0 SM 321 DI 16x24VDC 6ES7 321-1BH82-0AA0 SM321 DI32x24VDC 6ES7 321-1BL00-0AA0 SM321 DI 32xDC24V SM321 DI 64xDC24V SM321 DI 16xAC/DC24..48V SM321 DI 16xDC48..120V SM321 DI 16xDC48..120V SM321 DI 16xAC120V SM321 DI 32xAC120V SM321 DI8x230VAC 6ES7 321-1BL80-0AA0 SM 321 DI 8xAC120/230V SM 321 DI 8x120/230VAC SM321 DI16x120V/230VAC SM321 DI 16x24VDC, Interrupt SM321 DI 16xDC24V, Alarm SM 321 DI 16x24VDC, Interrupt 6ES7 321-1BP00-0AA0 6ES7 321-1CH00-0AA0 6ES7 321-1CH20-0AA0 6ES7 321-1CH80-0AA0 6ES7 321-1EH01-0AA0 6ES7 321-1EL00-0AA0 6ES7 321-1FF01-0AA0 6ES7 321-1FF10-0AA0 6ES7 321-1FF81-0AA0 6ES7 321-1FH00-0AA0 6ES7 321-7BH00-0AB0 6ES7 321-7BH01-0AB0 6ES7 321-7BH80-0AB0 SM321 DI4xNAMUR, Ex 6ES7 321-7RD00-0AB0 SM 321, DI 16xNAMUR Properties: W = Module wizard: C = CiR support: R = Redundant I/O: T = Type discontinued: 6ES7 321-7TH00-0AB0 FW Version Short Description W SM - DI Digital input module DI 16x24VDC, rooting in groups of 16 Digital input module DI 16x24VDC, rooting in groups of 16 Digital input module DI 16xDC24V, rooting in groups of 16, High Speed, supports isochronous mode Digital input module DI 16x24VDC, rooting in groups of 16, M-reading SM321; Digital input module DI 16xDC24V, extended environmental conditions SM321; Digital input module DI 16x24VDC, extended environmental conditions Digital input module DI 32x24VDC, rooting in groups of 32 Digital input module DI 32xDC24V, rooting in groups of 32 SM321; digital input module DI 64xDC24V, rooting in groups of 16, P- or M-reading Digital input module DI 16xAC/DC24..48V, rooting in groups of 1 Digital input module DI 16xDC48..120V, rooting in groups of 8 Digital input module DI 16xDC48..120V, rooting in groups of 8, environmental conditions Digital input module DI 16x120VAC, rooting in groups of 4 DI 32xAC 120V, 32Pt 120VAC Input - IEC Type II - 8 Pts/Comm Digital input module DI 8x120...230VAC, rooting in groups of 2 Digital input module DI8xAC ISO, single-channel rooting SM 321 DI 8xAC120/230V Digital input module DI 8x120/230VAC, extended environmental conditions SM321 DI16x120/230VAC; digital input module DI 16xAC120V /230V, rooting in groups of 4 Digital input module DI 16xDC24V, with hardware and diagnostic interrupt, rooting in groups of 16 Digital input module DI 16xDC24V, with hardware and diagnostic interrupt, rooting in groups of 16, supports isochronous mode Digital input module DI 16x24VDC, with hardware and diagnostic interrupt, rooting in groups of 16, extended environmental conditions Digital input module DI 4xNamur, with hardware and diagnostic interrupt, single-channel rooting, [EEx ib] Digital input module DI 16xNAMUR,with diagnostics function and quality code Properties C R T X M 10/04 X M X M X M X M 10/00 X M 11/03 X M X M X M X M X M X M 11/03 X M 09/01 X M X M X M X M X M X O M X O G X O X O C X O C M M 11/03 M 11/03 X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; X = Supported A = Redundant connection possible M = module-specific; G = group-specific; C = channel-specific (Please refer to the System Manual "SIMATIC Fault-tolerant Systems S7-400H") at specified date Page 26 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name SM322 DO8x24VDC/2A SM322 DO16x24VDC/0.5A SM322 DO 16xDC24V/0.5A MLFB 6ES7 322-1BF01-0AA0 6ES7 322-1BH01-0AA0 6ES7 322-1BH10-0AA0 SM 322 DO 6ES7 322-1BH81-0AA0 16x24VDC/0.5A SM322 6ES7 322-1BL00-0AA0 DO32x24VDC/0.5A SM322 6ES7 322-1BP00-0AA0 DO 64xDC24V/0.3A SM322 6ES7 322-1BP50-0AA0 DO 64xDC24V/0.3A SM322 6ES7 322-1CF00-0AA0 DO 8xDC48..120V/1.5A SM322 6ES7 322-1CF80-0AA0 DO8x48..120VDC/1.5A SM322 6ES7 322-1EH01-0AA0 DO16x120VAC/0.5A SM322 6ES7 322-1EL00-0AA0 DO 32xAC120V/1A SM322 DO8x230VAC/2A 6ES7 322-1FF01-0AA0 SM 322 DO 6ES7 322-1FF81-0AA0 8x120/230VAC/1A SM322 6ES7 322-1FH00-0AA0 DO16x120V/230VAC/0.5 A SM322 6ES7 322-1FL00-0AA0 DO 32xAC120V/230V/1A SM322 DO8xRel. 230VAC SM 322 DO 8xRel. 230VAC/5A SM322 DO 8xRel. AC 24V/5A 6ES7 322-1HF01-0AA0 6ES7 322-1HF10-0AA0 6ES7 322-1HF20-0AA0 SM322 DO 8xRel. 230VAC /5A 6ES7 322-1HF80-0AA0 SM322 DO16xRel. 120VAC SM322 DO16xRel. 120/230VAC SM322 DO 8xAC120/230V/2A 6ES7 322-1HH00-0AA0 6ES7 322-1HH01-0AA0 6ES7 322-5FF00-0AB0 SM322 6ES7 322-5GH00-0AB0 DO 16xUC24/48V SM322 6ES7 322-5HF00-0AB0 DO 8xRel AC230V SM322 6ES7 322-5RD00-0AB0 DO 4xDC15V/20mA, Ex SM322 DO 4x24VDC/10mA, Ex SM322 DO8x24VDC/0.5A SM 322 DO 8x24VDC/0.5A 6ES7 322-5SD00-0AB0 SM 322, DO 16x24VDC/0.5A SM322 DO 16xDC24V/0.5A SM322 DO 16xDC24V/0.5A 6ES7 322-8BH00-0AB0 Properties: W = Module wizard: C = CiR support: R = Redundant I/O: T = Type discontinued: 6ES7 322-8BF00-0AB0 6ES7 322-8BF80-0AB0 6ES7 322-8BH01-0AB0 6ES7 322-8BH10-0AB0 FW Version Short Description W SM - DO Digital output module 8DO 24 VDC/2 A, rooting in groups of 4 Digital output module 16DO 24 VDC/0.5 A, rooting in groups of 8 Digital output module 16DO 24 VDC/0.5 A, rooting in groups of 8, High Speed, supports isochronous mode Digital output module 16DO 24 VDC/0.5 A, extended environmental conditions Digital output module 32DO 24 VDC/0.5 A, rooting in groups of 8 Digital output module DO 64xDC24V/0.3A, rooting in groups of 16, P-switching Digital output module DO 64xDC24V/0.3A, rooting in groups of 16, M-switching Digital output module 8DO 48..120 VDC/1.5 A, rooting in groups of 4 Digital output module 8DO 48..120 VDC/1.5 A, rooting in groups of 4, extended environmental conditions Digital output module DO 16x120VAC/0.5A, rooting in groups of 8 Digital output module 32DO 120V AC/1 A, rooting in groups of 8 Digital output module 8DO 120...230VAC/1 A, rooting in groups of 4, Si. Digital output module 8DO 120/230 VAC/1 A, extended environmental conditions Digital output module 16DO 120/230 VAC/0.5 A, rooting in groups of 8 Properties C R T X M X M X M X M X M X M X M X M X M 11/03 X M 01/02 X M 10/04 X M X M X M Digital output module 32DO 120-230V AC/1 A, rooting in groups of 8 X M Digital output module DO 8xREL 24 VDC/2 A, 230V AC/2 A, rooting in groups of 2 Digital output module DO 8xREL 230 VAC, 5 A, single-channel rooting Digital output module DO 8xREL 24 VDC/5 A, 230 VAC/5 A, single-channel rooting, with overvoltage protection element SM 322 DO 8xRel. AC 230V/5A; Digital output module DO 8xREL. 230V AC, 5A, single-channel rooting, extended environmental conditions Digital output module DO 16xREL 24 VDC/2 A, 120V/2 A, rooting in groups of 16 Digital output module DO 16xREL 24 VDC/2 A, 120V/2 A, 230 V/?A, rooting in groups of 16 SM322; Digital output module DO DO8xAC120/230V, with value substitution X M X M X M 07/02 X M 11/03 X M 07/02 X M X O X M X O Digital output module DO 4xDC15V/20mA, diagnostic interrupt, single-channel rooting, [EEx ib] X O Digital output module 4DO 24 VDC/10 mA, diagnostic interrupt, single-channel rooting, [EEx ib] Digital output module 8DO 24 VDC/0.5 A, diagnostic interrupt, rooting in groups of 8 Digital output module 8DO 24 VDC/0.5 A, with diagnostics function, extended environmental conditions Digital output module, 16DO 24 VDC/0.5 A, with diagnostics function Digital output module, 16DO 24 VDC/0.5 A, with diagnostics function Digital output module, 16DO 24 VDC/0.5 A, with diagnostics function X O C X O M X O X O M X O M X O M Digital output module DO 16xUC24/48V diagnostic interrupt, single-channel rooting, Digital output module DO 8xAC230V, x A M 11/03 M M 10/03 11/03 12/03 X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; X = Supported A = Redundant connection possible M = module-specific; G = group-specific; C = channel-specific (Please refer to the System Manual "SIMATIC Fault-tolerant Systems S7-400H") at specified date Page 27 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version Short Description W SM323 6ES7 323-1BH01-0AA0 DI 8/DO 8 x DC24V/0.5A SM - DI/DO SM 323 DI 8/8DO 24 VDC/0.5A; digital I/O module 8DI /8DO 24 VDC/0.5A, SM323 6ES7 323-1BH81-0AA0 DI 8/DO 8 x DC24V/0.5A SM 323 DI 8/8DO 24 VDC/0.5A; digital I/O module, 8DI/8DO 24 VDC/0.5A, outdoor SM 326, DI 24x24VDC 6ES7 326-1BK00-0AB0 SM - DI - F SM 326 F, 24DI 24 VDC, safety-oriented SM326 DI 24xDC24V SM326 DI 24xDC24V SM 326, DI 8xNAMUR, Ex(i) 6ES7 326-1BK01-0AB0 SM 326, DO 10x24VDC/2A SM326 DO 10xDC24V/2A SM326 DO 10xDC24V/2A SM 326F DO 8xDC24V/2A SM 326F DO 8xDC24V/2A Properties: W = Module wizard: C = CiR support: R = Redundant I/O: T = Type discontinued: Properties C R X M X M X OS C 04/06 X OS C 09/09 11/03 X OS C 6ES7 326-1RF00-0AB0 SM 326 F, 24DI 24 VDC, safety oriented, with diagnostic interrupt SM 326 F, 24DI 24 VDC, safety oriented, with diagnostic interrupt SM 326 F, 8DI NAMUR, Ex(i), safety-oriented X OS C 6ES7 326-2BF00-0AB0 SM - DO - F SM326 F, 10DO 24 VDC/2 A, safety oriented X OS C X OS C X OS C 6ES7 326-1BK02-0AB0 6ES7 326-2BF01-0AB0 6ES7 326-2BF10-0AB0 6ES7 326-2BF40-0AB0 6ES7 326-2BF41-0AB0 SM 326F, 10DO 24 VDC/2A, P switching, safetyoriented, with diagnostic interrupt SM 326F, 10DO 24 VDC/2A, P switching, safetyoriented, with diagnostic interrupt, Profibus DP and PROFInet with PROFIsafe V2 SM 326F, 8DO 24 VDC/2A, P-M switching, safetyoriented, with diagnostic interrupt SM 326F, 8DO 24 VDC/2A, P-M switching, safetyoriented, with diagnostic interrupt T X 04/03 09/09 X X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; OS = In standard mode only X = Supported A = Redundant connection possible M = module-specific; G = group-specific; C = channel-specific (Please refer to the System Manual "SIMATIC Fault-tolerant Systems S7-400H") at specified date Page 28 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version Short Description W Properties C R T SM 331 AI 8x13 bits 6ES7 331-1KF00-0AB0 SM - AI Analog input module AI 8x13 bits X O SM331 AI 8x13Bit SM331 AI 8x14Bit 6ES7 331-1KF01-0AB0 Analog input module AI 8x13 bits X O 6ES7 331-7HF01-0AB0 Analog input module AI 8x14 bits, high-speed module, supports isochronous mode X O SM331 AI2x12 bits 6ES7 331-7KB01-0AB0 Analog input module AI 2x12...14 bits X O SM331 AI2x12 bits 6ES7 331-7KB02-0AB0 Analog input module AI 2x12...14 bits X O SM 331 AI 2x12 bits 6ES7 331-7KB81-0AB0 X O 05/01 SM331 AI2x12 bits 6ES7 331-7KB82-0AB0 Analog input module AI 2x12...14 bits, extended environmental conditions Analog input module AI 2x12...14 bits, Outdoor X O 11/03 SM331 AI8x12 bits 6ES7 331-7KF01-0AB0 Analog input module AI 8x12...14 bits X O 02/05 SM331 AI8x12 bits 6ES7 331-7KF02-0AB0 Analog input module AI 8x12...14 bits X O M SM331 AI8x16 bits 6ES7 331-7NF00-0AB0 O C SM331 AI8x16 bits 6ES7 331-7NF10-0AB0 O C SM331 AI 6xTC 6ES7 331-7PE10-0AB0 Analog input module; AI8x16 bits; 1 V to 5 V, +/- 5 V, X +/- 10 V; 0..20 mA, 4..20 mA, +/- 20 mA SM331 AI8x16Bit; Analog input module; AI8x16 bits; X 1 V to 5 V, +/- 5 V, +/- 10 V; 0..20 mA, 4..20 mA, +/20 mA Analog input module AI6xTC, 16 bits, ISO, suitable for X channel-selective redundancy O C SM331 AI8xRTD 6ES7 331-7PF00-0AB0 SM331 AI 8xRTD 6ES7 331-7PF01-0AB0 SM331 AI8xTC 6ES7 331-7PF10-0AB0 SM331 AI 8xTC 6ES7 331-7PF11-0AB0 SM331 AI4x0/4...20mA, Ex SM331 AI8xTC/4xRTD, Ex SM 331 AI2x0/4...20mA HART, EX 6ES7 331-7RD00-0AB0 SM 331 AI8x0/4...20mA HART SM331 AI 8x0/4...20mA HART, Properties: W = Module wizard: C = CiR support: R = Redundant I/O: T = Type discontinued: 6ES7 331-7SF00-0AB0 Analog input module AI8xRTD, 16 bits (internal 24 bits according to the Sigma-Delta process); RTD: Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, Cu10 Analog input module. AI8xRTD, 16 bits (internal. 24 bits according to the Sigma-Delta process); RTD: Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, Cu10 Analog input module AI8xTC, 16 bits (internal 24 bits according to the Sigma-Delta process); thermocouples: B, E, J, K, L, N, R, S, T Analog input module. AI8xTC, 16 bits (internal 24 bits according to the Sigma-Delta process); thermocouples: B, E, J, K, L, N, R, S, T Analog input module AI 4x0/4...20mA, 15 bits, [EEx ib] Analog input module AI 8xTC/4xRTD, 15 bits, [EEx ib] X O X O X O X O X O X O 6ES7 331-7TB00-0AB0 Analog input module AI2x0/4...20mA, with HART communication, [EEx ib] X O 6ES7 331-7TF00-0AB0 Analog input module AI8x0/4...20mA, +/-20mA with HART communication Analog input module AI8x0/4...20mA,+/-20mA with HART communication X O X O 6ES7 331-7TF01-0AB0 10/03 10/04 04/05 07/05 C C X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; OS = In standard mode only X = Supported A = Redundant connection possible M = module-specific; G = group-specific; C = channel-specific (Please refer to the System Manual "SIMATIC Fault-tolerant Systems S7-400H") at specified date Page 29 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB SM332 AO2x12 bits 6ES7 332-5HB01-0AB0 SM 332 AO 2x12 bits 6ES7 332-5HB81-0AB0 SM332 AO4x12 bits 6ES7 332-5HD01-0AB0 FW Version Short Description W SM - AO Analog output module AO 2x12 bits Analog output module AO 2x12...14 bits, extended environmental conditions Analog output module AO 4x11...12 bits Properties C R X O X O X O C X O C X O C X O T 11/03 SM332 6ES7 332-5HF00-0AB0 AO 8x12Bit SM332 AO4x0/4...20mA, 6ES7 332-5RD00-0AB0 Ex SM 332, AO2x0/4...20mA 6ES7 332-5TB00-0AB0 HART, EX Analog output module AO 4x0/4...20mA, 15 bits, [EEx ib] Analog output module AO2x0/4...20mA, with HART communication, [EEx ib] SM332 SM332, analog output module; 4x16 bits X O 10/04 SM332, analog output module; 4x16 bits supports isochronous mode SM332, analog output module; 4x16 bits supports isochronous mode Analog output module 8x16Bit, 0/4..20mA, with HART communication Analog output module 8x16Bit, 0/4..20mA, with HART communication SM - AI - F Analog input module AI 6x13 bits, safety-oriented up to SIL-3, with diagnostics function Analog input module AI 6x0/4...20mA HART, PROFIsafe V2, safety-oriented, with diagnostics interrupt, with HART communication, FW update, redundancy X O 01/05 X O X O X O C X OS C X OS C 6ES7 332-7ND00-0AB0 SM332 6ES7 332-7ND01-0AB0 AO 4x16 bits SM332 6ES7 332-7ND02-0AB0 AO 4x16 bits SM332 6ES7 332-8TF00-0AB0 AO 8x0/4...20mA HART SM332 6ES7 332-8TF01-0AB0 AO 8x0/4...20mA HART SM 336, AI 6x13 bits 6ES7 336-1HE00-0AB0 SM336 AI 6 HART 6ES7 336-4GE00-0AB0 Properties: W = Module wizard: C = CiR support: R = Redundant I/O: T = Type discontinued: X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; OS = In standard mode only X = Supported A = Redundant connection possible M = module-specific; G = group-specific; C = channel-specific (Please refer to the System Manual "SIMATIC Fault-tolerant Systems S7-400H") at specified date Page 30 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version Short Description W T SM - MTA MTA 16 channels DI; 24 VDC for 6ES7321-7BH01-0AB0 (as of E version 02) MTA 16 channels DI Standard 6ES7650-1AC10-3XX0 MTA 16 channels DI Standard 6ES7650-1AC11-3XX0 MTA 16 channels DI; 24 VDC for 6ES7321-7BH01-0AB0 (as of E version 2) MTA 8 channels AI Standard 6ES7650-1AA50-2XX0 MTA 8 channels AI; 1-5 V / 0/4-20 mA; for 6ES7331-7NF00-0AB0 (as of E version 05) MTA 8 channels AI Standard 6ES7650-1AA51-2XX0 MTA 8 channels AI; 1-5 V / 0/4-20 mA; for 6ES7331-7NF00-0AB0 (as of E version 5) MTA 8 channels AI HART Standard MTA 8 channels AO Standard 6ES7650-1AA61-2XX0 MTA 8 channels AI; 0/4-20 mA; for 6ES7 331-7TF01-0AB0 6ES7650-1AB50-2XX0 MTA 8 channels AO; 4-20 mA; for 6ES7332-5HF00-0AB0 (as of E version 03) MTA 8 channels AO Standard 6ES7650-1AB51-2XX0 MTA 8 channels AO; 4-20 mA; for 6ES7332-5HF00-0AB0 (as of E version 3) MTA 8 channels AO HART Standard MTA 8 channels TC Standard 6ES7650-1AB61-2XX0 MTA 8 channels AO; 0/4-20 mA; for 6ES7332-8TF01-0AB0 6ES7650-1AF50-2XX0 MTA 8 channels TC; for 6ES7331-7PF10-0AB0 (as of E version 04) and 6ES7 331-7PF11-0AB0 MTA 8 channels TC Standard 6ES7650-1AF51-2XX0 MTA 8 channels TC; for 6ES7331-7PF10-0AB0 (as of E version 4) and 6ES7 331-7PF11-0AB0 MTA 8 channels RTD Standard 6ES7650-1AG50-2XX0 MTA 8 channels RTD; for 6ES7331-7PF00-0AB0 (as of E version 08) and 6ES7331-7PF01-0AB0 MTA 8 channels RTD Standard 6ES7650-1AG51-2XX0 MTA 8 channels RTD; for 6ES7331-7PF00-0AB0 (as of E version 8) and 6ES7331-7PF01-0AB0 MTA 24 channels F-DI (fail-safe) 6ES7650-1AK10-7XX0 MTA 24 channels F-DI (fail-safe) 6ES7650-1AK11-7XX0 MTA 10 channels F-DO (fail-safe) 6ES7650-1AL10-6XX0 MTA 24 channels F-DI; 24 VDC; for 6ES7326-1BK00-0AB0 and 6ES7326-1BK01-0AB0 (as of E revision 1) MTA 24 channels F-DI; 24 VDC; for 6ES7326-1BK00-0AB0 and 6ES7326-1BK01-0AB0 (as of E version 1) MTA 10 channels F-DO; 24 VDC/2 A; for 6ES7326-2BF01-0AB0 (as of E version 02) MTA 10 channels F-DO (fail-safe) 6ES7650-1AL11-6XX0 MTA 10 channels F-DO; 24 VDC / 2A; for 6ES7326-2BF01-0AB0 (as of E version 2) MTA 16 channels DO (relays) 6ES7650-1AM30-3XX0 MTA 16 channels relays DO; 120-230 VAC, 5 A; 24 V DC,5 A; 6ES7322-8BH01-0AB0 (as of E version 1) MTA 10 channels DO (relays) 6ES7650-1AM30-6XX0 MTA 10 channels relay DO; 110-220 VAC/5 A; 24 VDC/5 A; for 6ES7326-2BF01-0AB0 (as of E version 02) MTA 10 channels F-DO (fail-safe, relays) 6ES7650-1AM31-6XX0 MTA 10 channels F-DO; relays 120-230 VAC, 5 A; 24 VDC,5 A; for 6ES7326-2BF01-0AB0 (as of E version 2) MTA 6 channels F-AI (fail-safe) 6ES7650-1AH50-5XX0 MTA 6 channels F-AI; 4-20 mA; for 6ES7336-1HE00-0AB0 (as of E version 06) MTA 6 channels F-AI (fail-safe) 6ES7650-1AH51-5XX0 MTA 6 channels F-AI; 4-20 mA; for 6ES7336-1HE00-0AB0 (as of E version 6) MTA 6 channels F-AI (fail-safe) 6ES7650-1AH61-5XX0 MTA 6 channels F-AI; 4-20 mA; for 6ES7336-1HE00-0AB0 (as of E version 6) for 6ES7336-4GE00-0AB0 Properties: R = Redundant I/O: Properties C R X = Supported A = Redundant connection possible M = module-specific; C = channel-specific Page 31 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB Redundant Power 6ES7650-1BA01-0XX0 Monitor Redundant Power 6ES7650-1BA02-0XX0 Monitor 5.6 V Zehner diode board 6ES7650-1BB51-0XX0 6.2 V Zehner diode board 6ES7650-1BC51-0XX0 FET switch adapter Properties: R = Redundant I/O: 6ES7650-1BD51-0XX0 FW Version Short Description W Properties C R T SM - MTA Redundant Power Monitor Redundant Power Monitor 5.6 V Zehner diode daughter board for F-AI MTA 6.2 V Zehner diode daughter board for F-AI MTA FET switch adapter X = Supported A = Redundant connection possible M = module-specific; C = channel-specific Page 32 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version Short Description W Properties C R T S7-400 CP - Ethernet S7 CP for Industrial Ethernet with SEND-RECEIVE interface, S7 communication S7 CP for Industrial Ethernet with SEND-RECEIVE interface, S7 communication, routing, module replacement without programming device S7 CP for Industrial Ethernet with TCP/IP, with SENDRECEIVE interface, S7 Communication, routing, module replacement without programming device CP 443-1 6GK7 443-1BX00-0XE0 CP 443-1 ISO 6GK7 443-1BX01-0XE0 CP 443-1 TCP 6GK7 443-1EX01-0XE0 CP 443-1 6GK7 443-1EX02-0XE0 V5.2 CP 443-1 6GK7 443-1EX10-0XE0 V1.0 CP 443-1 6GK7 443-1EX10-0XE0 CP 443-1 02/03 02/03 02/03 S7 CP for Industrial Ethernet ISO and TCP/IP with SEND-RECEIVE and FETCH-WRITE interface, long data, UDP, TCP, S7 functions, routing, module replacement without programming device S7 CP for Industrial Ethernet ISO and TCP/IP with SEND-RECEIVE and FETCH-WRITE interface, long data, UDP, TCP, S7 functions, routing, module replacement without programming device, 10/100 Mbit Fast Send/Receive 02/03 V2.x S7 CP for Industrial Ethernet ISO and TCP/IP with SEND-RECEIVE- and FETCH-WRITE interface, long data, UDP, TCP, S7 functions, routing, module replacement without programming device, 10/100 Mbit Fast Send/Receive 01/01 6GK7 443-1EX11-0XE0 V1.1 CP 443-1 6GK7 443-1EX11-0XE0 V2.x CP 443-1 6GK7 443-1EX20-0XE0 V2.x S7 CP for Industrial Ethernet ISO and TCP/IP with SEND-RECEIVE and FETCH-WRITE interface, long data, UDP, TCP, S7 functions, routing, module replacement without programming device, 10/100 Mbit S7 CP for Industrial Ethernet ISO and TCP/IP with SEND-RECEIVE- and FETCH-WRITE interface, long data, UDP, TCP, S7 functions, routing, module replacement without programming device, 10/100 Mbit, NTP, static MAC address. S7 CP for Industrial Ethernet ISO and TCP/IP with SEND-RECEIVE and FETCH-WRITE interface, long data, UDP, TCP, S7 functions, routing, module replacement without programming device, 10/100 Mbit, NTP, static MAC address, 2-port switch CP 443-5 Extended 6GK7 443-5DX01-0XE0 CP 443-5 Extended 6GK7 443-5DX02-0XE0 V3.x CP 443-5 Extended 6GK7 443-5DX03-0XE0 V4.x CP 443-5 Extended 6GK7 443-5DX03-0XE0 V5.x CP 443-5 Extended 6GK7 443-5DX04-0XE0 V6.x Properties: W = Module wizard: C = CiR support: R = Redundant I/O: T = Type discontinued: 01/01 CP - Profibus CP for Profibus with PROFIBUS DP, SENDRECEIVE interface, FMS and S7 Communication; Sync/Freeze PROFIBUS CP: DP master with Sync/Freeze and redundancy, slave-cross traffic, constant bus cycle time, SEND-RECEIVE interface, S7 functions, time-of day, PG routing, data set routing, firmware V3.3 PROFIBUS CP: DP master with Sync/Freeze and X redundancy, direct data exchange, constant bus cycle time, SEND-RECEIVE interface, S7 functions, time synchronization, routing, data set routing, DPV1, firmware V4.0 PROFIBUS CP: DP master with Sync/Freeze and X redundancy, direct data exchange, constant bus cycle time, SEND-RECEIVE interface, S7 functions, time synchronization, data set routing, DPV1, CIR, firmware V5.x PROFIBUS CP: DP master with Sync/Freeze and X redundancy, direct data exchange, constant bus cycle time, SEND-RECEIVE interface, S7 functions, time synchronization, data set routing, DPV1, CIR, firmware V6.x 10/01 08/01 05/05 X 05/05 X X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; X = Supported A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 33 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FM458-1 DP 6DD1607-0AA2 EXM 438-1 6DD1607-0CA1 EXM 448-2 6DD1607-0EA2 FW Version V2.x Short Description W Properties C R T FM Application module for SIMATIC S7-400: designed to realise high performant and free configurable control tasks. 1DP-connection, 60MB user program memory, OEM Knowhow protection I/O expansion module for FM458 Communication expansion module for FM458 1) CPU before 04/99 (up to PCS7 V4.02) S7 CPU; work memory 384K; 0.1 ms/kA; 8K DI/O; 32 connections; MPI and PROFIBUS DP connection CPU 414-2 DP 6ES7 414-2XJ00-0AB0 CPU 414-2 DP 6ES7 414-2XJ01-0AB0 S7 CPU; work memory 384K; 0.1 ms/kA; 8K DI/O; 32 connections; MPI and PROFIBUS DP connection 03/00 CPU 416-2 DP 6ES7 416-2XK00-0AB0 04/98 CPU 416-2 DP 6ES7 416-2XK01-0AB0 CPU 416-2 DP 6ES7 416-2XL00-0AB0 CPU 416-2 DP 6ES7 416-2XL01-0AB0 S7 CPU; work memory 0.8 MB; 0.08 ms/kA; 16K DI/O; 64 connections; MPI and PROFIBUS DP connection S7 CPU; work memory 0.8 MB; 0.08 ms/kA; 16K DI/O; 64 connections; MPI and PROFIBUS DP connection S7 CPU; work memory 1.6 MB; 0.08 ms/kA; 16K DI/O; 64 connections; MPI and PROFIBUS DP connection S7 CPU; work memory 1.6 MB; 0.08 ms/kA; 16K DI/O; 64 connections; MPI and PROFIBUS DP connection 1) 04/98 02/01 05/98 02/01 The CPUs of this generation are only supported by the driver concept up to PCS7 V4.02 An upgrade of the driver concept as of PCS7 V5.0 is not possible. Properties: W = Module wizard: C = CiR support: R = Redundant I/O: T = Type discontinued: X = Supported X = Supported X = Supported; A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 34 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version Short Description W Properties C R T 1) CPU as of 04/99 (as of PCS7 V5.0) V1.1 S7 CPU; work memory 384K code and 384K data; 0.1 ms/kA; 8K DI/O; 32 connections; 2*DP/MPI and 1 receptacle for IF submodules; constant bus cycle time CPU 414-3 6ES7 414-3XJ00-0AB0 CPU 414-3 6ES7 414-3XJ00-0AB0 V1.2 S7 CPU; work memory 384K code and 384K data; 0.1 ms/kA; 8K DI/O; 32 connections; 2*DP/MPI and 1 receptacle for IF submodules; constant bus cycle time, cross-traffic; routing CPU 414-3 6ES7 414-3XJ00-0AB0 CPU 414-3 X 01/05 X 01/05 V3.0 Work memory 384K code and 384K data; 0.1 ms/kA; X 8K DI/O; 32 connections; 2*DP/MPI and 1 receptacle for intelligent submodules; direct data exchange, constant bus cycle time; routing; DPV1; firmware V3.0 01/05 6ES7 414-3XJ00-0AB0 V3.1 Work memory 384K code and 384K data; 0.1 ms/kA; 8K DI/O; 32 connections 2*DP/MPI and 1 receptacle for I submodules; direct data exchange, constant bus cycle time; routing; DPV1; firmware V3.1 X CPU 416-2 6ES7 416-2XK02-0AB0 V1.1 S7 CPU; work memory 0.8 MB code and 0.8 MB data; 0.08 ms/kA; 16K DI/O; 64 connections; 2*DP/MPI; constant bus cycle time X 01/05 CPU 416-2 6ES7 416-2XK02-0AB0 V1.2 S7 CPU; work memory 0.8 MB code and 0.8 MB data; 0.08 ms/kA; 16K DI/O; 64 connections; 2*DP/MPI; constant bus cycle time, cross-traffic; routing X 01/05 CPU 416-2 6ES7 416-2XK02-0AB0 V3.0 Work memory 0.8 MB code and 0.8 MB data; 0.08 ms/kA; 16K DI/O; 64 connections; 2*DP/MPI; direct data exchange, constant bus cycle time; routing; DPV1; firmware V3.0 X 01/05 CPU 416-2 6ES7 416-2XK02-0AB0 V3.1 Work memory 0.8 MB code and 0.8 MB data; 0.08 ms/kA; 16K DI/O; 64 connections; 2*DP/MPI; direct data exchange, constant bus cycle time; routing; DPV1; firmware V3.1 X CPU 416-3 6ES7 416-3XL00-0AB0 V1.1 S7 CPU; work memory 1.6 MB code and 1.6MB data; 0.08 ms/kA; 16KB DI/O; 64 connections; 2*DP/MPI and 1 receptacle for IF submodules; constant bus cycle time X 01/05 CPU 416-3 6ES7 416-3XL00-0AB0 V1.2 S7 CPU; work memory 1.6 MB code and 1.6MB data; 0.08 ms/kA; 16K DI/O; 64 connections; 2*DP/MPI and 1 receptacle for IF submodules; constant bus cycle time, cross traffic; routing X 01/05 CPU 416-3 6ES7 416-3XL00-0AB0 V3.0 Work memory 1.6 MB code and 1.6 MB data; 0.08 X ms/kA; 16K DI/O; 64 connections; 2*DP/MPI and 1 receptacle for IF submodules; direct data exchange, constant bus cycle time; routing; DPV1; firmware V3.0 01/05 CPU 416-3 CPU 416-3 V3.1 Work memory 1.6 MB code and 1.6 MB data; 0.08 X ms/kA; 16K DI/O; 64 connections; 2*DP/MPI and 1 receptacle for IF submodules; direct data exchange, constant bus cycle time; routing; DPV1; firmware V3.1 1) X X X 01/05 01/05 01/05 The new driver concept (PCS7 V5.2) is only supported by the CPUs with the FW V3.0 or higher Properties: W = Module wizard: C = CiR support: R = Redundant I/O: T = Type discontinued: X = Supported X = Supported XE = Standalone only; X = Supported A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 35 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version Short Description W Properties C R T 1) CPU as of 04/99 (as of PCS7 V5.0) V1.1 S7 CPU; work memory 2 MB code and 2 MB data, (expandable up to 20 MB); 0.1 ms/kA; 16K DI/O; 64 connections; 2*DP/MPI and 2 slots for IF submodules; receive functionality for cross-traffic; constant bus cycle time; routing; firmware V1.1 V1.2.0 S7 CPU; work memory 2 MB code and 2 MB data, (expandable up to 20 MB); 0.1 ms/kA; 16K DI/O; 64 connections; 2*DP/MPI and 2 slots for IF submodules; constant bus cycle time/cross-traffic; routing V3.0 Work memory 2 MB code and 2 MB data, (expandable up to 20 MB); 0.1 ms/kA; 16K DI/O; 64 connections; 2*DP/MPI and 2 slots for IF submodules; receive functionality for direct data exchange, constant bus cycle time, routing, DPV1, firmware V3.0 V3.1 Work memory 2 MB code and 2 MB data, (expandable up to 20 MB); 0.1 ms/kA; 16K DI/O; 64 connections; 2*DP/MPI and 2 slots for IF submodules; receive functionality for direct data exchange, constant bus cycle time, routing, DPV1, firmware V3.1 V2.1.1 Redundant CPU with fails-safe functionality, work V2.1.2 memory 384K code and 384K data; 0.1 ms/kA; 8K DI/O; 32 connections; 2*DP/MPI and 2 slots for HSync submodules CPU 417-4 6ES7 417-4XL00-0AB0 CPU 417-4 6ES7 417-4XL00-0AB0 CPU 417-4 6ES7 417-4XL00-0AB0 CPU 417-4 6ES7 417-4XL00-0AB0 CPU 414-4H 6ES7 414-4HJ00-0AB0 CPU 414-4H 6ES7 414-4HJ00-0AB0 V3.0 CPU 414-4H 6ES7 414-4HJ00-0AB0 CPU 417-4H X 01/05 X 01/05 X 01/05 X X 01/05 X 01/06 Redundant CPU with fail-safe functionality, work memory 384K code and 384K data; 0.1 ms/kA; 8 K DI/O; 32 connections; 2*DP/MPI and 2 slots for HSync submodules, direct data exchange, DPV1; firmware V3.0 X 01/06 V3.1 Redundant CPU with fails-safe functionality, work memory 384K code and 384K data; 0.1 ms/kA; 8K DI/O; 32 connections; 2*DP/MPI and 2 slots for HSync submodules, direct data exchange, DPV1; firmware V3.1 X 6ES7 417-4HL00-0AB0 V2.0 V2.1.x Redundant CPU; work memory 2 MB code and 2 MB data; (expandable up to 20 MB); 0.1 ms/kA; 16K DI/O; 64 connections; 2*DP/MPI and 2 slots for IF submodules, routing, firmware V2.0 X 09/00 CPU 417-4H 6ES7 417-4HL01-0AB0 V2.1 Redundant, work memory 2 MB code and 2 MB data; (expandable up to 20 MB); 0.1 ms/kA; 16K DI/O; 64 connections; 2*DP/MPI and 2 slots for H-Sync submodules, routing, firmware V2.1 X 01/06 CPU 417-4H 6ES7 417-4HL01-0AB0 V2.1.1 V2.1.2 Redundant, work memory 2 MB code and 2 MB data; (expandable up to 20 MB); 0.1 ms/kA; 16K DI/O; 64 connections; 2*DP/MPI and 2 slots for H-Sync submodules, routing, firmware V2.1 X 01/06 CPU 417-4H 6ES7 417-4HL01-0AB0 V3.0 Redundant CPU, fails-safe functionality, work memory 2 MB code and 2 MB data; (expandable up to 20 MB); 0.1 ms/kA; 16K DI/O; 64 connections; 2*DP/MPI and 2 slots for H-Sync submodules, direct data exchange, routing, DPV1, firmware V3.0 X 01/06 CPU 417-4H 6ES7 417-4HL01-0AB0 V3.1 Redundant CPU with fails-safe functionality, work memory 2 MB code and 2 MB data; (expandable up to 20 MB); 0.1 ms/kA; 16K DI/O; 64 connections; 2*DP/MPI and 2 slots for H-Sync submodules, direct data exchange, routing, DPV1, firmware V3.1 X 1) X X 01/06 01/06 The new driver concept (PCS7 V5.2) is only supported by the CPUs with the FW V3.0 or higher Properties: W = Module wizard: C = CiR support: R = Redundant I/O: T = Type discontinued: X = Supported X = Supported X = Supported; A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 36 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version Short Description W CPU as of 08/04 (as of PCS7 V6.1) V4.x S7 CPU; work memory 0.7 MB code and 0.7 MB data; 0.06 ms/kAW; 8K DI/O; 32 connections; 1*DP/MPI, 1*DP and 1slot for IF submodules; send and receive functionality for direct data exchange; constant bus cycle time and isochronous mode; routing; firmware V4.0 CPU 414-3 6ES7 414-3XJ04-0AB0 CPU 416-2 6ES7 416-2XK04-0AB0 V4.x CPU 416-3 6ES7 416-3XL04-0AB0 CPU 417-4 Properties C R T X X 03/07 S7 CPU; work memory 1.4 MB code and 1.4 MB data; 0.04 ms/kAW; 16K DI/O; 64 connections; 1*DP/MPI and 1*DP; send and receive functionality for direct data exchange; constant bus cycle time and isochronous mode; routing; firmware V4.0 X X 03/07 V4.x S7 CPU; work memory 2.8 MB code and 2.8 MB data; 0.04 ms/kAW; 16K DI/O; 64 connections; 1*DP/MPI, 1*DP and 1 slot for IF submodules; send and receive functionality for direct data exchange; constant bus cycle time and isochronous mode; routing; firmware V4.0 X X 03/07 6ES7 417-4XL04-0AB0 V4.x S7 CPU; work memory 10 MB code and 10 MB data; 0.03 ms/kAW; 16K DI/O; 64 connections; 1*DP/MPI, 1*DP and 2 slots for IF submodules; send and receive functionality for direct data exchange; constant bus cycle time and isochronous mode; routing; firmware V4.0 X X 03/07 CPU 414-4H 6ES7 414-4HJ04-0AB0 V4.x S7 CPU; supports redundant and fail-safe mode, work memory 0.7 MB code and 0.7 MB data; 0.08 ms/kAW; 8K DI/O; 32 connections; 1*DP/MPI, 1*DP and 2 slots for H-Sync submodules; firmware V4.0 X X 01/10 CPU 417-4H 6ES7 417-4HL04-0AB0 V4.x S7 CPU; supports redundant and fail-safe mode; work memory 10 MB code and 10 MB data; 0.03 ms/kAW; 16K DI/O; 64 connections; 1*DP/MPI, 1*DP und 2 slots for H-Sync submodules; firmware V4.0 X X 01/10 Properties: W = Module wizard: C = CiR support: X = Supported X = Supported R = Redundant I/O: T = Type discontinued: X = Supported; A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 37 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version 6ES7 414-3XM05-0AB0 CPU 414-3 DP 6ES7 414-3XM05-0AB0 V5.1 .. V5.3 CPU 414-3 PN/DP 6ES7 414-3EM05-0AB0 V5.0 CPU 414-3 PN/DP 6ES7 414-3EM05-0AB0 V5.1 .. V5.3 CPU 416-2 DP 6ES7 416-2XN05-0AB0 CPU 416-2 DP 6ES7 416-2XN05-0AB0 Properties: W = Module wizard: C = CiR support: X = Supported X = Supported T = Type discontinued: W CPU as of 12/06 (as of PCS7 V7.0) V5.0 S7 CPU; work memory 1.4 MB code and 1.4 MB data; 0.045 ms/kAW; 8K DI/O; 32 connections; 1*DP/MPI, 1*DP and 1 slot for IF modules; supports redundant and fail-safe mode for direct data communication; constant bus cycle time and isochronous mode; routing; firmware V5.0 CPU 414-3 DP R = Redundant I/O: Short Description Properties C R X X X X X X S7 CPU; work memory 1.4 MB code and 1.4 MB data; 0.045 ms/kAW; 8K DI/O; 32 connections; 1*DP/MPI, 1*PN and 1 slot for IF modules; send and receive functionality for direct data communication; constant bus cycle time and isochronous mode; routing; integrated data record gateway; firmware V5.1 .. V5.3 X X V5.0 S7 CPU; work memory 2.8 MB code and 2.8 MB data; 0.030 ms/kAW; 16K DI/O; 64 connections; 1*DP/MPI and 1*DP; send and receive functionality for direct data communication; constant bus cycle time and isochronous mode; routing; firmware V5.0 X X V5.1 .. V5.3 S7 CPU; work memory 2.8 MB code and 2.8 MB data; 0.030 ms/kAW; 16K DI/O; 64 connections; 1*DP/MPI and 1*DP; send and receive functionality for direct data communication; constant bus cycle time and isochronous mode; routing; integrated data record gateway; firmware V5.1 .. V5.3 X X S7 CPU; work memory 1.4 MB code and 1.4 MB data; 0.045 ms/kAW; 8K DI/O; 32 connections; 1*DP/MPI, 1*DP and 1 slot for IF modules; send and receive functionality for direct data communication; constant bus cycle time and isochronous mode; routing; integrated data record gateway; firmware V5.1 .. V5.3 S7 CPU; work memory 1.4 MB code and 1.4 MB data; 0.045 ms/kAW; 8K DI/O; 32 connections; 1*DP/MPI, 1*PN and 1 slot for IF module; send and receive functionality for direct data communication; constant bus cycle time and isochronous mode; routing; firmware V5.0 T X = Supported; A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 38 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version 6ES7 416-3XR05-0AB0 CPU 416-3 DP 6ES7 416-3XR05-0AB0 CPU 416-3 PN/DP 6ES7 416-3ER05-0AB0 CPU 416-3 PN/DP 6ES7 416-3ER05-0AB0 CPU 417-4 DP 6ES7 417-4XT05-0AB0 V5.0 CPU 417-4 DP 6ES7 417-4XT05-0AB0 V5.1 .. V5.3 CPU 414-3 PN/DP 6ES7 414-3EM06-0AB0 CPU 416-3 PN/DP 6ES7 416-3ES06-0AB0 Properties: W = Module wizard: C = CiR support: X = Supported X = Supported T = Type discontinued: W CPU as of 12/06 (as of PCS7 V7.0) V5.0 S7 CPU; work memory 5.6 MB code and 5.6 MB data; 0.030 ms/kAW; 16K DI/O; 64 connections; 1*DP/MPI, 1*DP and 1 slot for IF module; send and receive functionality for direct data communication; constant bus cycle time and isochronous mode; routing; firmware V5.0 V5.1 .. S7 CPU; V5.3 work memory 5.6 MB code and 5.6 MB data; 0.030 ms/kAW; 16K DI/O; 64 connections; 1*DP/MPI, 1*DP and 1 slot for IF modules; send and receive functionality for direct data communication; constant bus cycle time and isochronous mode; routing; firmware V5.1 .. V5.3 V5.0 S7 CPU; work memory 5.6 MB code and 5.6 MB data; 0.030 ms/kAW; 16K DI/O; 64 connections; 1*DP/MPI, 1*PN and 1 slot for IF module; send and receive functionality for direct data communication; constant bus cycle time and isochronous mode; routing; ; firmware V5.0 V5.1 .. S7 CPU; V5.3 work memory 5.6 MB code and 5.6 MB data; 0.030 ms/kAW; 16K DI/O; 64 connections; 1*DP/MPI, 1*PN and 1 slot for IF modules; send and receive functionality for direct data communication; constant bus cycle time and isochronous mode; routing; firmware V5.1 .. V5.3 CPU 416-3 DP R = Redundant I/O: Short Description Properties C R X X X X X X X X S7 CPU; work memory 15 MB code and 15 MB data; 0.018 ms/kAW; 16K DI/O; 64 connections; 1*DP/MPI, 1*DP and 2 slots for IF modules; send and receive functionality for direct data communication; constant bus cycle time and isochronous mode; routing; firmware V5.0 X X S7 CPU; work memory 15 MB code and 15 MB data; 0.018 ms/kAW; 16K DI/O; 64 connections; 1*DP/MPI, 1*DP and 2 slots for IF modules; send and receive functionality for direct data communication; constant bus cycle time and isochronous mode; routing; firmware V5.1 .. V5.3 X X X X X X CPU as of 08/10 (as of PCS7 V7.1.2) V6.x S7 CPU; work memory 2,0 MB code and 2,0 MB data; 0.045 ms/kAW; 8K DI/O; 64 connections; 1*DP/MPI, 1*PN and 1 slot for IF module; send and receive functionality for direct data communication; constant bus cycle time and isochronous mode; routing; firmware V6.x V6.x S7 CPU; work memory 8,0 MB code and 8,0 MB data; 0.030 ms/kAW; 16K DI/O; 96 connections; 1*DP/MPI, 1*PN and 1 slot for IF modules; send and receive functionality for direct data communication; constant bus cycle time and isochronous mode; routing; firmware V6.x T X = Supported; A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 39 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version 6ES7 412-3HJ14-0AB0 CPU 414-4H 6ES7 414-4HM14-0AB0 V4.5 CPU 417-4H 6ES7 417-4HT14-0AB0 V4.5 Properties: W = Module wizard: C = CiR support: X = Supported X = Supported T = Type discontinued: W CPU as of 09/07(as of PCS7 V7.0.1) V4.5 S7 CPU; Supports redundant and fail-safe mode; work memory 0.5 MB code und 0.25 MB data; 0.075 ms/kAW; 8K DI/O; 16 connections; 1*DP/MPI, 1*DP and 2 slots for H-Sync modules; firmware V4.5 CPU 412-3H R = Redundant I/O: Short Description Properties C R X X S7 CPU; Supports redundant and fail-safe mode; work memory 1.4 MB code and 1.4 MB data; 0.045 ms/kAW; 8K DI/O; 32 connections; 1*DP/MPI, 1*DP and 2 slots for H-Sync modules; firmware V4.5 X X S7 CPU; Supports redundant and fail-safe mode; work memory 15MB code und 15MB data; 0.018 ms/kAW; 16KB DI/O; 64 connections; 1*DP/MPI, 1*DP and 2 slots for H-Sync modules; firmware V4.5 X X T X = Supported; A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 40 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version Short Description W IM Send IM, 3m, without voltage transmission, with communication bus Send IM for central coupling up to 3 m, no 5 V signal transmission, with communication bus IM 460-0 6ES7 460-0AA00-0AB0 IM 460-0 6ES7 460-0AA01-0AB0 IM 460-1 6ES7 460-1BA00-0AB0 IM 460-1 6ES7 460-1BA01-0AB0 IM 460-3 6ES7 460-3AA00-0AB0 IM 460-3 6ES7 460-3AA01-0AB0 IM 460-4 6ES7 460-4AA01-0AB0 IM 461-0 6ES7 461-0AA00-0AA0 IM 461-0 6ES7 461-0AA01-0AA0 Receive IM for central coupling up to 3m, voltage signal transmission, with communication bus IM 461-1 6ES7 461-1BA00-0AA0 Receive IM, 1.5 m, with 5 V signal transmission, no communication bus IM 461-1 6ES7 461-1BA01-0AA0 Receive IM for central coupling up to 1.5 m, with voltage signal transmission, no communication bus IM 461-3 6ES7 461-3AA00-0AA0 IM 461-3 6ES7 461-3AA01-0AA0 IM 461-4 6ES7 461-4AA01-0AA0 IM 463-2 6ES7 463-2AA00-0AA0 Receive IM, 100 m, no voltage signal transmission, with communication bus Receive IM, 100 m, no voltage signal transmission, with communication bus Receive IM, 600 m, no voltage signal transmission, with communication bus Send IM, 600 m, for interconnection S5-EG with IM314 Properties: W = Module wizard: C = CiR support: R = Redundant I/O: T = Type discontinued: Properties C R T 12/01 Send IM, 1.5 m, with voltage signal transmission, no communication bus Send IM for central coupling up to 1.5m; with voltage signal transmission, without communication bus 12/01 Send IM, 100 m, no voltage signal transmission, with communication bus Send IM, 100 m, no voltage signal transmission, with communication bus Send IM, 600 m, voltage signal transmission, no communication bus Receive IM for central coupling up to 3 m, voltage signal transmission, with communication bus 12/01 12/01 12/01 12/01 X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; X = Supported A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 41 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB FW Version Short Description W PS 405 10 A PS 405 10 A 6ES7 405-0KA00-0AA0 6ES7 405-0KA01-0AA0 PS Power supply 24 VDC/10 A PS 405, 24 VDC/10 A standard PS PS 405 10 A 6ES7 405-0KA02-0AA0 PS 405, 24 VDC/10 A, ATEX approval PS 405 20 A 6ES7 405-0RA01-0AA0 PS 405, 24 VDC/20 A, standard PS PS 405 20 A 6ES7 405-0RA02-0AA0 PS 405, 24 VDC/20 A, standard PS, ATEX approval PS 405 10 A 6ES7 405-0KR00-0AA0 PS 405, 24 VDC/10 A, redundant PS PS 405 10 A 6ES7 405-0KR02-0AA0 PS 407 10 A PS 407 10 A 6ES7 407-0KA00-0AA0 6ES7 407-0KA01-0AA0 PS 405, 24 VDC/10 A, redundant PS, ATEX approved Power supply 120/230 VAC/10 A PS 407, 120/230 VAC / 10 A, standard PS PS 407 10 A 6ES7 407-0KA02-0AA0 PS 407, 120/230 VAC / 10 A, standard PS PS 407 20 A 6ES7 407-0RA01-0AA0 PS 407, 120/230 VAC / 20 A, standard PS PS 407 20 A 6ES7 407-0RA02-0AA0 PS 407, 120/230 VAC / 20 A, standard PS PS 407 10 A 6ES7 407-0KR00-0AA0 PS 407, 120/230 VAC / 10 A, redundant PS PS 407 10 A 6ES7 407-0KR02-0AA0 PS 407, 120/230 VAC / 10 A, redundant PS UR2 6ES7 400-1JA00-0AA0 Racks Universal rack, 9 slots, not suitable for redundant power supply modules UR2 6ES7 400-1JA01-0AA0 UR2; universal rack, 9 slots UR2ALU 6ES7 400-1JA11-0AA0 UR1 6ES7 400-1TA00-0AA0 UR2; universal aluminum rack, 9 slots Universal rack, 18 slots, not suitable for redundant power supply modules UR1 6ES7 400-1TA01-0AA0 UR1; universal rack, 18 slots UR1ALU 6ES7 400-1TA11-0AA0 UR2-H 6ES7 400-2JA00-0AA0 UR2ALU-H 6ES7 400-2JA10-0AA0 UR1; universal aluminum rack, 18 slots Central rack, 18 slots, 2 segments (9+9), preferably used for H systems Central aluminum rack, 18 slots, 2 segments (9+9), preferably used for H systems Properties: W = Module wizard: C = CiR support: R = Redundant I/O: T = Type discontinued: Properties C R T 02/01 03/05 03/99 01/98 08/98 X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; X = Supported A = Redundant connection possible M = module-specific; C = channel-specific at specified date Page 42 of 43 Release 01.04.2011 A5E02124692-03 SIMATIC PCS 7 - Released Modules Product Name MLFB SM421 DI32x24VDC 6ES7 421-1BL00-0AA0 SM421 DI32x24VDC 6ES7 421-1BL01-0AA0 SM421 DI32x120VAC 6ES7 421-1EL00-0AA0 SM421 DI16x120/230VUC SM421 DI16x120/230VUC 6ES7 421-1FH00-0AA0 6ES7 421-1FH20-0AA0 SM421 DI16x24VDC 6ES7 421-7BH00-0AB0 SM421 DI 16xDC 24V 6ES7 421-7BH01-0AB0 SM421 DI16x24/60VUC 6ES7 421-7DH00-0AB0 interrupt SM421 DI16x120VAC 6ES7 421-5EH00-0AA0 SM422 DO16x24VDC/2A SM422 DO16x24VDC/2A SM422 DO32x24VDC/0.5A SM422 DO8x 120/230VAC/5A SM422 DO16x120/230VAC/2A SM422 DO16x 230VAC/5A Relays SM422 DO32x 24VDC/0.5A 6ES7 422-1BH10-0AA0 6ES7 422-1BH11-0AA0 6ES7 422-1BL00-0AA0 6ES7 422-1FF00-0AA0 6ES7 422-1FH00-0AA0 6ES7 422-1HH00-0AA0 6ES7 422-7BL00-0AB0 SM422 DO16x 6ES7 422-5EH00-0AB0 120VAC/2A SM422 6ES7 422-5EH10-0AB0 DO16x 20-125VDC/1.5A SM431 AI16x13 bits 6ES7 431-0HH00-0AB0 SM431 AI8 x 13 bits 6ES7 431-1KF00-0AB0 SM431 AI8 x 14 bits 6ES7 431-1KF10-0AB0 SM431 AI8 x 14 bits 6ES7 431-1KF20-0AB0 SM431 AI16 x 16 bits 6ES7 431-7QH00-0AB0 SM431 AI8 x 16 bits 6ES7 431-7KF00-0AB0 SM431 AI8 x 16 bits 6ES7 431-7KF10-0AB0 SM432 AO8 x 13 bits 6ES7 432-1HF00-0AB0 Properties: W = Module wizard: C = CiR support: R = Redundant I/O: T = Type discontinued: FW Version Short Description W SM - DI Digital input module; 32 DI, 24 VDC, rooting in groups of 32 Digital input module; 32 DI, 24 VDC, rooting in groups of 32 Digital input module; 32 DI, 120 V UC, rooting in groups of 8 Digital input module; 16 DI, 120/230 V UC, rooting in groups of 4 Digital input module; 16 DI, 120/230 V UC, rooting in groups of 4, input characteristic to IEC 1131, type 2 Digital input module; 16 DI, 24VDC, single-channel rooting, process and diagnostic interrupt, substitute values can be assigned as parameters Digital input module; 16 DI, DC 24 V, rooting in groups of 8, process and diagnostic interrupt, substitute values can be assigned as parameters Digital input module; 16 DI, 24...60 V UC, singlechannel rooting, process and diagnostic interrupt Digital input module; 16 DI, 120 VAC, single-channel rooting, input characteristic to IEC 1131, type 2 SM - DO Digital output module; 16 DO 24 VDC/2 A, rooting in groups of 8 Digital output module; 16 DO 24 VDC/2 A, rooting in groups of 8 Digital output module; 32 DO 24 VDC/0.5 A, rooting in groups of 32 Digital output module; 8DO 120/230 VAC/5 A, singlechannel rooting Digital output module; 16 DO 120/230 VAC/2 A, rooting in groups of 4 Digital output module; DO 16xrel., 230 VAC/60 VDC/5 A, rooting in groups of 4 Digital output module; 32 DO, 24 VDC/0.5 A, rooting in groups of 8, diagnostics, programmable substitute values Digital output module 16 DO, 120 VAC/2 A, diagnostics Digital output module 16 DO, 20-125 VDC/1.5 A, diagnostics, rooting in groups of 8 SM - AI Analog input module; AI 16x13 bits, integration time 16.7/20 ms Analog input module AI 8x12+1 bits, integration time 16.7/20 ms Analog input module AI 8x13+1 bits, integration time 16.7/2 0ms; linearization (RTD/TC) Analog input module AI 8x13+1 bits, conversion time 10 s Analog input module AI 16x15+1 bits, integration time 16.7/20 ms; linearization (RTD/TC), diagnostics Analog input module "TC/U" 8 channels, isolated per channel Analog input module "RTD" 16 bits, 8 channels SM - AO Analog output module AO 8x13 bits, conversion time 420 s, 0 V to 10 V/0..20 mA Properties C R X T 10/04 X X X 08/02 X X 10/04 X X X 10/04 X 10/04 X X X 10/04 X X X X 10/04 X 10/04 X X X X X X X X X = Supported X = Station insertion/removal by means of CiR is supported; S = Station can be reprogrammed in "online" mode; M = Module insertion/removal by means of CiR is supported; O = Module can be reprogrammed in "online" mode; X = Supported A = Redundant connection possible T = TIA release only M = module-specific; C = channel-specific at specified date Notice: The SIPLUS versions of the modules contained in this document are also released for PCS7. Page 43 of 43 Release 01.04.2011 A5E02124692-03