G6A-BS BABT Approved Relay BABT Approved Relay Meeting the Requirements of EN41003:1993 as endorsed, formerly BS6301:1989 Amendment 5 for Supplementary Isolation BABT BABT Approved No. CR/0098. Height of only 8mm from PCB. Wide switching load - 10A to 2A. Fully sealed construction. Ordering Information Single-side Stable Type Model Classification G6A-234P-BS Note: Contact Form - DPDT Contact Type - Bifurcated crossbar Contact Material - AgPd+Au clad Structure - Plastic sealed When ordering, add the rated coil voltage to the model number. Example: G6A-234P-BS 12 VDC Rated coil voltage Specifications Coil Ratings General purpose, DPDT Relays Rated voltage (VDC) 3 4.5 5 6 9 12 24 48 Rated current (mA) 93.8 62.5 56.2 46.5 31.1 23.3 11.7 7.0 Coil resistance () 32 72 89 129 289 514 2,057 6,882 Coil inductance Armature OFF 0.07 0.16 0.2 0.29 0.63 1.1 4.5 13.7 (H) (ref. value) 0.065 0.14 0.18 0.26 0.57 1.06 4.1 12.5 Armature ON Must operate voltage 70% max. of rated voltage Must release voltage 10% min. of rated voltage Max. voltage 150% of rated voltage at 23_C, 150% at 70_C Power consumption Approx. 280 mW Approx. 330 mW Contact Ratings Item G6A-234P-BS Load Resistive load (cos = 1) Inductive load (cos = 0.4; L/R = 7 ms) Rated load 0.3 A at 125 VAC; 1 A at 30 VDC 0.2 A at 125 VAC; 0.5 A at 30 VDC Contact material AgPd (Au-clad) Rated carry current 3A Max. switching voltage 250 VAC, 220 VDC Max. switching current DC: 2A; AC: 2 A DC: 1 A; AC: 1 A Max. switching capacity 125 VA, 60 W 62.5 VA, 30 W Min. permissible load 0.01 mA at 10 mVDC G6A-BS G6A-BS Characteristics (at Ambient Temperature 23_C) Contact resistance 50 m max. Operate (set) time 5 ms max. Release (reset) time 3 ms max. Max. operating frequency Mechanical: 36,000 operations/hr Electrical: 1,800 operations/hr (under rated load) Insulation resistance 1,000 M min. (at 500 VDC) Dielectric withstand voltage 1,000 VAC, 50/60 Hz for 1 min between open contacts 2,000 VAC, 50/60 Hz for 1 min between coil and contacts Impulse withstand voltage 1,500 V 10 x 160 s (conforms to FCC Part 68) Vibration resistance Destruction: 10 to 55 Hz, 5-mm double amplitude Malfunction: 10 to 55 Hz, 3.3-mm double amplitude Shock resistance Destruction: 1,000 m/s2 (approx. 100G) Malfunction: DPDT: 500 m/s2 (approx. 50G) Life expectancy Mechanical: 100,000,000 operations min. (at 36,000 operations/hr) Electrical: 500,000 operations min. (at 1,800 operations/hr) Ambient temperature Operating: -40_C to 70_C (with no icing) Storage: -40_C to 70_C (with no icing) Ambient humidity Operating: 45% to 85% Weight DPDT: Approx. 3.5 g Note: The data shown above are initial values. Dimensions Note: 1. Orientation marks are indicated as follows: (20)* 20.2 max. Mounting Holes (Bottom View) Tolerance: +0.1 Terminal Arrangement/ Internal Connections (Bottom View) G6A-234P-BS (9.9)* 10.1 max. 7.62 1+ 0.64 (8.2)* 8.4 max. 3.16 16 - 8 4 6 13 11 5.08 5.08 (1.2) (1.2) 7.62 9 (1.2) 0.3 0.6 (1.2) 7.62 Eight, 1.0-dia. holes