SMSC EMC2302 DATASHEET Revision 1.3 (05-18-1 1)
Datasheet
PRODUCT FEATURES
EMC2302
Dual RPM-Based PWM Fan Controller
General Description
The EMC2302 is an SMBus compliant fan controller with
up to two independently controlled PWM fan drivers.
Each fan driver is controlled by a programmable
frequency PWM driver and Fan Speed Control algorithm
that operates in either a closed loop fashion or as a
directly PWM-controlled device.
The closed loop Fan Speed Control algorithm (FSC) has
the capability to detect aging fans and alert the system.
It will likewise detect stalled or locked fans and trigger
an interrupt.
Additionally, the EMC2302 offers a clock output so that
multiple devices may be chained and slaved to the
same clock source for optimal performance in large
distributed systems.
Applications
Servers
Projectors
Industrial and Networking Equipment
Notebook Computers
Features
Two Programmable Fan Control circuits (EMC2302)
4-wire fan compatible
High speed PWM (26 kHz)
Low speed PWM (9.5Hz - 2240 Hz)
Optional detection of aging fans
Fan Spin Up Control and Ramp Rate Control
Alert on Fan Stall
Watchdog Timer
RPM-based fan control algorithm
0.5% accuracy from 500 RPM to 16k RPM (external
crystal oscillator)
1% accuracy from 500 RPM to 16k RPM (internal clock)
SMBus 2.0 Compliant
SMBus Alert compatible
CLK Pin can provide a clock source output
Available in a 10-pin MSOP Lead-free RoHS
Compliant package
Block Diagram
SMBus
Slave
Protocol
PWM
Drivers
SMCLK
SMDATA
Tachometer
Limit
Registers
Tach
Measurement
CLK
ALERT#
Fan Speed Control Algorithm
Fan Speed Control Algorithm
TACH1
TACH2
PWM1
PWM2
Order Number(s):
This product meets the halogen maximum concentration values per IEC61249-2-21
For RoHS compliance and environmental information, please visit www.smsc.com/rohs
ORDERING NUMBER PACKAGE FEATURES
EMC2302-1-AIZL-TR 10-pin MSOP (Lead-free
RoHS compliant) Two RPM-based fan speed control
algorithms. SMBus address 0101_110(r/w)
EMC2302-2-AIZL-TR 10-pin MSOP (Lead-free
RoHS compliant) Two RPM-based fan speed control
algorithms. SMBus address 0101_111(r/w)
Dual RPM-Based PWM Fan Controller
Datasheet
Revision 1.3 (05-18-11) 2 SMSC EMC2302
DATASHEET
80 ARKAY DRIVE, HAUPPAUGE, NY 11788 (631) 435-6000 or 1 (800) 443-SEMI
Copyright © 2011 SMSC or its subsidiaries. All rights reserved.
Circuit diagrams and other informa tion relating to SMSC products are included as a means of illustrating typical applications. Consequently, complete information sufficient for
construction purposes is not necessarily given. Although the information has been checked and is believed to be accurate, no responsibility is assumed for in accuracies. SMSC
reserves the right to make changes to specifications and product descriptions at any time without notice. Contact your local SMSC sales office to obtain the latest specifications
before placing your product order. The provision of this information does not convey to the purchaser of the described semiconductor devices any licenses under any patent
rights or other intellectual property rights of SMSC or others. All sales are expressly conditional on your agreement to the terms and conditions of the most recently dated
version of SMSC's standard Terms of Sale Agreement dated before the date of your order (the "Terms of Sale Agreement"). The product may contain design defects or errors
known as anomalies which may cause the product's functions to deviate from published specifications. Anomaly sheets are available upon request. SMSC products are not
designed, intended, authorized or warranted for use in any life support or other application where product failure could cause or contribute to personal injury or severe property
damage. Any and all such uses without prior written approval of an Officer of SMSC and further testing and/or modification will be fully at the risk of the customer. Copies of
this document or other SMSC literature, as well as the Terms of Sale Agreement, may be obtained by visiting SMSC’s website at http://www.smsc.com. SMSC is a registered
trademark of Standard Microsystems Corporation (“SMSC”). Product names and company names are the trademarks of their respective holders.
SMSC DISCLAIMS AND EXCLUDES ANY AND ALL WARRANTIES, INCLUDING WITHOUT LIMITATION ANY AND ALL IMPLIED WARRANTIES OF MERCHAN TABILITY,
FITNESS FOR A PARTICULAR PURPOSE, TITLE , AND AGAINST INFRINGEMENT AND THE LIKE, AND ANY AND ALL WARRANTIES ARISING FROM ANY COURSE
OF DEALING OR USAGE OF TRADE. IN NO EVENT SHALL SMSC BE LIABLE FOR ANY DIRECT, INCIDENTAL, INDIRECT, SPECIAL, PUNITIVE, OR CONSEQUENTIAL
DAMAGES; OR FOR LOST DATA, PROFITS , SAVINGS OR REVENUES OF ANY KIND; REGARDLESS OF THE FORM OF ACTION, WHETHER BASED ON CONTRACT;
TORT; NEGLIGENCE OF SMSC OR OTHERS ; STRICT LIABILITY; BREACH OF WARRANTY; OR OTHERWISE; WHETHER OR NOT ANY REMEDY OF BUYER IS HELD
TO HAVE FAILED OF ITS ESSENTIAL PURPOSE, AND WHETHER OR NOT SMSC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE S.
Dual RPM-Based PWM Fan Controller
Datasheet
SMSC EMC2302 3 Revision 1.3 (05-18-11)
DATASHEET
Table of Contents
Chapter 1 Pin Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Chapter 2 Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.1 Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.2 SMBus Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Chapter 3 Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.1 System Management Bus Interface Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.1.1 SMBus Start Bit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.1.2 SMBus Address and RD / WR Bit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.1.3 SMBus Data Bytes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.1.4 SMBus ACK and NACK Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.1.5 SMBus Stop Bit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.1.6 SMBus Time-out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.1.7 SMBus and I2C Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.2 SMBus Protocols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.2.1 Write Byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.2.2 Read Byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.2.3 Send Byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.2.4 Receive Byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.2.5 Block Write Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.2.6 Block Read Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.2.7 Alert Response Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Chapter 4 Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
4.1 Fan Control Modes of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
4.2 PWM Fan Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.3 RPM-based Fan Speed Control Algorithm (FSC). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.3.1 Programming the RPM-based Fan Speed Control Algorithm . . . . . . . . . . . . . . . . . . . . . 18
4.4 Tachometer Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4.4.1 Stalled Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4.4.2 Aging Fan or Invalid Drive Detection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4.5 CLK Pin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4.5.1 External Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4.5.2 Internal Clock. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4.6 Spin Up Routine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4.7 Ramp Rate Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4.8 Watchdog Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
4.8.1 Power Up Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
4.8.2 Continuous Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Chapter 5 Register Set. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
5.1 Register Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
5.1.1 Lock Entries. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
5.2 Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
5.3 Fan Status Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
5.3.1 Fan Status - 24h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
5.3.2 Fan Stall Status - 25h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
5.3.3 Fan Spin Status - 26h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
5.3.4 Fan Drive Fail Status - 27h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Dual RPM-Based PWM Fan Controller
Datasheet
Revision 1.3 (05-18-11) 4 SMSC EMC2302
DATASHEET
5.4 Fan Interrupt Enable Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
5.5 PWM Configuration Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
5.5.1 PWM Polarity Config - 2Ah . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
5.5.2 PWM Output Config - 2Bh. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
5.6 PWM Base Frequency Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
5.7 Fan Setting Registers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
5.8 PWM Divide Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
5.9 Fan Configuration 1 Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
5.10 Fan Configuration 2 Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
5.11 Gain Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
5.12 Fan Spin Up Configuration Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
5.13 Fan Max Step Registers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
5.14 Fan Minimum Drive Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
5.15 Valid TACH Count Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
5.16 Fan Drive Fail Band Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
5.17 TACH Target Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
5.18 TACH Reading Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
5.19 Software Lock Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
5.20 Product ID Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
5.21 Manufacturer ID Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
5.22 Revision Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Chapter 6 Typical Operating Curves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Chapter 7 Package Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
7.1 EMC2302 Package Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
7.2 Package Markings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Chapter 8 Datasheet Revision History. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Dual RPM-Based PWM Fan Controller
Datasheet
SMSC EMC2302 5 Revision 1.3 (05-18-11)
DATASHEET
List of Figures
Figure 1.1 EMC2302 Pin Diagram (10-Pin MSOP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Figure 3.1 SMBus Timing Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Figure 4.1 System Diagram of EMC2302 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Figure 4.2 Spin Up Routine. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Figure 4.3 Ramp Rate Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Figure 7.1 EMC2302 Package Drawing - 10-Pin MSOP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Figure 7.2 EMC2302 Package Markings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Dual RPM-Based PWM Fan Controller
Datasheet
Revision 1.3 (05-18-11) 6 SMSC EMC2302
DATASHEET
List of Tables
Table 1.1 Pin Description for EMC2302 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Table 1.2 Pin Types. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Table 2.1 Absolute Maximum Ratings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Table 2.2 Electrical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Table 2.3 SMBus Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Table 3.1 Protocol Format. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Table 3.2 Write Byte Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Table 3.3 Read Byte Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Table 3.4 Send Byte Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Table 3.5 Receive Byte Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Table 3.6 Block Write Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Table 3.7 Block Read Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Table 3.8 Alert Response Address Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Table 4.1 Fan Controls Active for Operating Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Table 5.1 EMC2302 Register Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Table 5.2 Configuration Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Table 5.3 Fan Status Registers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Table 5.4 Fan Interrupt Enable Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Table 5.5 PWM Configuration Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Table 5.6 PWM Base Frequency Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Table 5.7 PWM_BASEx[1:0] Bit Decode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Table 5.8 Fan Driver Setting Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Table 5.9 PWM Divide Registers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Table 5.10 Fan Configuration 1 Registers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Table 5.11 Range Decode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Table 5.12 Minimum Edges for Fan Rotation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Table 5.13 Update Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Table 5.14 Fan Configuration 2 Registers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Table 5.15 Derivative Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Table 5.16 Error Range Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Table 5.17 Gain Registers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Table 5.18 Gain Decode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Table 5.19 Fan Spin Up Configuration Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Table 5.20 DRIVE_FAIL_CNT[1:0] Bit Decode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Table 5.21 Spin Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Table 5.22 Spin Time. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Table 5.23 Fan Max Step Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Table 5.24 Minimum Fan Drive Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Table 5.25 Valid TACH Count Registers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Table 5.26 Fan Drive Fail Band Registers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Table 5.27 TACH Target Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Table 5.28 TACH Reading Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Table 5.29 Software Lock Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Table 5.30 Product ID Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Table 5.31 Manufacturer ID Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Table 5.32 Revision Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Table 8.1 Customer Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Dual RPM-Based PWM Fan Controller
Datasheet
SMSC EMC2302 7 Revision 1.3 (05-18-11)
DATASHEET
Chapter 1 Pin Description
Figure 1.1 EMC2302 Pin Diagram (10-Pin MSOP)
Table 1.1 Pin Description for EMC2302
PIN NUMBER PIN NAME PIN FUNCTION PIN TYPE
1SMDATA
SMBus data input/output - requires
external pull-up resistor DIOD (5V)
2SMCLK
SMBus clock input - requires external
pull-up resistor DI (5V)
3 VDD Power Supply Power
4 GND Ground Power
5PWM1
Push-Pull PWM output driver for Fan 1 DO
Open Drain PWM output driver for Fan 1 OD (5V)
6TACH1
Open drain tachometer input for Fan 1-
requires pull-up resistor DI (5V)
7PWM2
Push-Pull PWM output driver for Fan 2 DO
Open Drain PWM output driver for Fan 2 OD (5V)
8TACH2
Open drain tachometer input for Fan 2 -
requires pull-up resistor DI (5V)
EMC2302
10-MSOP
1
2
3
10
9
8
VDD
SMCLK
PWM1
SMDATA
CLK
GND
TACH1
PWM2
TACH2
ALERT#
4
5
7
6
Dual RPM-Based PWM Fan Controller
Datasheet
Revision 1.3 (05-18-11) 8 SMSC EMC2302
DATASHEET
The pin types are described in detail below. All pins labeled with (5V) are 5V tolerant.
APPLICATION NOTE: For the 5V tolerant pi ns that have a pull-up resistor, the voltage difference between VDD and
the 5V tolerant pad must never be more than 3.6V.
9CLK
Clock input for tachometer measurement DI (5V)
Push Pull Clock output to other fan
controllers to synchronize Fan Speed
Control DO
10 ALERT# Active low interrupt - requires external
pull-up resistor. OD (5V)
Table 1.2 Pin Types
PIN TYPE DESCRIPTION
Power This pin is used to supply power or ground to the device.
DI Digital Input - this pin is used a s a digital input. This pin is
5V tolerant.
DO Push / Pull Digital Output - this pin is used as a digital
output. It can both source and sink current.
DIOD Digital Input / Open Drain Output this pin is used as a
digital I/O. When it is used as an output, it is open drain
and requires a pull-up resistor. This pin is 5V tolerant.
OD Open Drain Digital Output - this pin is used as a digital
output. It is open drain and re quires a pull-up resistor. This
pin is 5V tolerant.
Table 1.1 Pin Description fo r EMC2302 (continue d)
PIN NUMBER PIN NAME PIN FUNCTION PIN TYPE
Dual RPM-Based PWM Fan Controller
Datasheet
SMSC EMC2302 9 Revision 1.3 (05-18-11)
DATASHEET
Chapter 2 Electrical Specifications
Note: Stresses above those listed could cause permanent damage to the device. This is a stress
rating only and functional operation of the device at any other condition above those indicated
in the operation sections of this specification is not implied.
Note 2.1 For the 5V tolerant pins that have a pull-up resistor, the pull-up voltage must not exceed
3.6V when the EMC2302 is unpowered.
2.1 Electrical Specifications
Table 2.1 Absolute Maximum Ratings
Voltage on 5V tolerant pins (V5VT_pin)-0.3 to 5.5 V
Voltage on 5V tolerant pins (|V5VT_pin - VDD|) (see Note 2.1)0 to 3.6 V
Voltage on VDD pin -0.3 to 4 V
Voltage on any other pin to GND -0.3 to VDD + 0.3 V
Package Thermal Restance - Junction to Ambient (θJA) 132 °C/W
Operating Ambient Temperature Range -40 to 125 °C
Storage Temperature Range -55 to 150 °C
ESD Rating, All Pins, HBM 2000 V
Table 2.2 Electrical Specifications
VDD = 3V to 3.6V, TA = -40°C to 125°C, all Typical values at TA = 27°C unless otherwise noted.
CHARACTERISTIC SYMBOL MIN TYP MAX UNIT CONDITIONS
DC Power
Supply Voltage VDD 33.33.6V
Supply Current IDD 400 550 uA
PWM Fan Driver
PWM Resolution PWM 256 Steps
PWM Duty Cycle DUTY 0 100 %
RPM-based Fan Controller
Tachometer Range TACH 480 16000 RPM
Tachometer Setting
Accuracy ΔTACH ±0.5 ±1 % External oscillator 32.768kHz
ΔTACH ±1 ±2 % Internal Oscillator
Input High Voltage VIH 2.0 V
Dual RPM-Based PWM Fan Controller
Datasheet
Revision 1.3 (05-18-11) 10 SMSC EMC2302
DATASHEET
Note 2.2 All voltages are relative to ground.
2.2 SMBus Electrical Specifications
Input Low Voltage VIL 0.8 V
Output High Voltage VOH VDD -
0.4 V8 mA current drive
Output Low Voltage VOL 0.4 V 8 mA current sink
Leakage current ILEAK ±5 uA ALERT# pin
Powered and unpowered
0°C < TA < 85°C
pull-up voltage < 3.6V
Table 2.3 SMBus Electrical Specifications
VDD= 3V to 3.6V, TA = -40°C to 125°C Typical values are at TA = 27°C unless otherwise noted.
CHARACTERISTIC SYMBOL MIN TYP MAX UNITS CONDITIONS
SMBus Interface
Input High Voltage VIH 2.0 V
Input Low Voltage VIL 0.8 V
Output High Voltage VOH VDD
- 0.4 V
Output Low Voltage VOL 0.4 V 4 mA current sink
Input High/Low Current IIH / IIL ±5 uA Powered and unpowered
0°C < TA < 85°C
Input Capacitance CIN 5pF
SMBus Timing
Clock Frequency fSMB 10 400 kHz
Spike Suppression tSP 50 ns
Bus free time Start to
Stop tBUF 1.3 us
Setup Time: Start tSU:STA 0.6 us
Setup Time: Stop tSU:STP 0.6 us
Data Hold Time tHD:DAT 0us
Data Setup Time tSU:DAT 0.6 us
Table 2.2 Electrical Specifications (continued)
VDD = 3V to 3.6V, TA = -40°C to 125°C, all Typical values at TA = 27°C unless otherwise noted.
CHARACTERISTIC SYMBOL MIN TYP MAX UNIT CONDITIONS
Dual RPM-Based PWM Fan Controller
Datasheet
SMSC EMC2302 11 Revision 1.3 (05-18-11)
DATASHEET
Clock Low Period tLOW 1.3 us
Clock High Period tHIGH 0.6 us
Clock/Data Fall time tFALL 300 ns Min = 20+0.1CLOAD ns
Clock/Data Rise time tRISE 300 ns Min = 20+0.1CLOAD ns
Capacitive Load CLOAD 400 pF per bus line
Table 2.3 SMBus Electrical Specifications (continu ed)
VDD= 3V to 3.6V, TA = -40°C to 125°C Typical values are at TA = 27°C unless otherwise noted.
CHARACTERISTIC SYMBOL MIN TYP MAX UNITS CONDITIONS
Dual RPM-Based PWM Fan Controller
Datasheet
Revision 1.3 (05-18-11) 12 SMSC EMC2302
DATASHEET
Chapter 3 Communications
3.1 System Management Bus Interface Protocol
The EMC2302 communicates with a host controller, such as an SMSC SIO, through the SMBus. The
SMBus is a two-wire serial communication protocol between a computer host and its peripheral
devices. A detailed timi ng diagram is shown in Figure 3.1. Stretching of the SMCLK signal is supported;
however, the EMC2302 will not stretch the clock signal.
3.1.1 SMBus Start Bit
The SMBus Start bit is defined as a transition of the SMBus Data line from a logic ‘1’ state to a logic
‘0’ state while the SMBus Clock line is in a logic ‘1’ state.
3.1.2 SMBus Address and RD / WR Bit
The SMBus Address Byte consists of the 7-bit client address followed by a RD / WR indicator bit. If
this RD / WR bit is a logic ‘0’, then the SMBus Ho st is writing data to the client device. If this RD / WR
bit is a logic ‘1’, then the SMBus Host is reading data from the client device.
The EMC2302-1 SMBus address is set at 0101_110(r/w)b.
The EMC2302-2 SMBus address is set at 0101_111(r/w)b.
3.1.3 SMBus Data Bytes
All SMBus Data bytes are sent most significant bit first and composed of 8-bits of information.
3.1.4 SMBus ACK and NACK Bits
The SMBus client will acknowledge all data bytes that it receives (as well as the client address if it
matches and the ARA addre ss if the ALERT# pin is asserted). Th is is done by the client device pulli ng
the SMBus Data line low after the 8th bit of each byte that is transmitted.
The Host will NACK (not acknowledge) the data received from the client by holding the SMBus data
line high after the 8th data bit has been sent.
Figure 3.1 SMBus Timing Diagram
SMDATA
SMCLK
TLOW
TRISE
THIGH
TFALL
TBUF
THD:STA
PSS - Start Condition P - Stop Condition
THD:DAT TSU:DAT TSU:STA
THD:STA
P
TSU:STO
S
Dual RPM-Based PWM Fan Controller
Datasheet
SMSC EMC2302 13 Revision 1.3 (05-18-11)
DATASHEET
3.1.5 SMBus Stop Bit
The SMBus Stop bit is defined as a transition of the SMBus Data line from a logic ‘0’ state to a logic
‘1’ state while the SMBus clock line is in a logic ‘1’ state. When the EMC2302 detects an SMBus Stop
bit has been communicating with the SMBus protocol, it will reset its client interface and prepare to
receive further communications.
3.1.6 SMBus Time-out
The EMC2302 includes an SMBus timeout feature. Following a 30ms period of inactivity on the
SMBus, the device will time-out and reset the SMBus interface.
The SMBus timeout feature is disabled by default and can be enabled via clearing the DIS_TO bit in
the Configuration register (20h).
3.1.7 SMBus and I2C Compliance
The major difference between SMBus and I2C devices is highlighted here. For complete compliance
information refer to the SMBus 2.0 specification.
1. Minimum frequency for SMBus communications is 10kHz (I2C has no minimum frequency).
2. The slave protocol will reset if the clock is held low for longer than 30ms (I2C has no timeout).
3. The slave protocol will reset if both the clock and data lines are held high for longer than 150us.
4. I2C devices do not suppo rt the Ale rt Respon se Addre ss functionality (wh ich is op ti onal for SMBus).
5. The Block Read and Block Write protocols are only compliant with I2C data formatting. They do
not support SMBus formatting for Block Read and Block Write protocols.
3.2 SMBus Protocols
The EMC2302 is SMBus 2.0 compatible and supports Send Byte, Read Byte, Receive Byte and Write
Byte as valid protocols as shown below. It will respond to the Alert Response Address protocol but is
not in full compliance.
All of the below protocols use the conven tion in Table 3.1. When readi ng the protocol blocks, the value
of YYYY_YYYb should be replaced with the respective SMBus addresses.
3.2.1 Write Byte
The Write Byte is used to write one byte of data to the registers as shown below Table 3.2.
Table 3.1 Protocol Format
DATA SENT
TO DEVICE DAT A SENT TO
THE HOST
# of bits sent # of bits sent
Table 3.2 Write Byte Protocol
START SLAVE
ADDRESS WR ACK REGISTER
ADDRESS ACK REGISTER
DATA ACK STOP
1 -> 0 YYYY_YYYb 0 0 XXh 0 XXh 0 0 -> 1
Dual RPM-Based PWM Fan Controller
Datasheet
Revision 1.3 (05-18-11) 14 SMSC EMC2302
DATASHEET
3.2.2 Read Byte
The Read Byte protocol is used to read one byte of data from the registers as shown in Table 3.3.
3.2.3 Send Byte
The Send Byte protocol is used to set the internal address register pointer to the correct address
location. No data is transferred during the Send Byte protocol as shown in Table 3.4.
3.2.4 Receive Byte
The Receive Byte protocol is used to read data from a register when the internal register address
pointer is known to be at the right location (e.g. set via Send Byte). This is used for consecutive reads
of the same register as shown in Table 3.5.
3.2.5 Block Write Protocol
The Block Write is used to write multiple data bytes to a group of contiguous registers as shown in
Table 3.6. It is an extension of the Write Byte Protocol.
Table 3.3 Read Byte Protocol
START SLAVE
ADDRESS WR ACK Register
Address ACK START Slave
Address RD ACK Register
Data NACK STOP
1 -> 0 YYYY_YYYb 0 0 XXh 0 0 -> 1 Y YYY_YYYb 1 0 XXh 1 0 -> 1
Table 3.4 Send Byte Protocol
START SLAVE
ADDRESS WR ACK REGISTER
ADDRESS ACK STOP
1 -> 0 YYYY_YYYb 0 0 XXh 0 0 -> 1
Table 3.5 Receive Byte Protocol
START SLAVE
ADDRESS RD ACK REGISTER DATA NACK STOP
1 -> 0 YYYY_YYYb 1 0 XXh 1 0 -> 1
Table 3.6 Block Write Protocol
START SLAVE
ADDRESS WR ACK REGISTER
ADDRESS ACK REGISTER
DATA ACK
1 ->0 YYYY_YYYb 0 0 XXh 0 XXh 0
REGISTER
DATA ACK REGISTER
DATA ACK . . . REGISTER
DATA ACK STOP
XXh 0 XXh 0 . . . XXh 0 0 -> 1
Dual RPM-Based PWM Fan Controller
Datasheet
SMSC EMC2302 15 Revision 1.3 (05-18-11)
DATASHEET
3.2.6 Block Read Protocol
The Block Read is used to read multiple data bytes from a group of contiguous registers as shown in
Table 3.7. It is an extension of the Read Byte Protocol.
3.2.7 Alert Response Address
The ALERT# output can be used as a processor interrupt or as an SMBus Alert when configured to
operate as an interrupt.
When it detects that the ALERT# pin is asserted, the host will send th e Alert Response Address (ARA)
to the general address of 0001_100xb. All devices with active interrupts will respond with their client
address as shown in Table 3.8.
The EMC2302 will respond to the ARA in the following way if the ALERT# pin is asserted.
1. Send Slave Address and verify that full slave address was sent (i.e. the SMBus communication
from the device was not prematurely stopped due to a bus contention event).
2. Set the MASK bit to clear the ALERT# pin.
Table 3.7 Block Read Protocol
START SLAVE
ADDRESS WR ACK REGISTER
ADDRESS ACK START SLAVE
ADDRESS RD ACK REGISTER
DATA
1->0 YYYY_YYYb 0 0 XXh 0 1 ->0 YYYY_YYYb 1 0 XXh
ACK REGISTER
DATA ACK REGISTER
DATA ACK REGISTER
DATA ACK . . . REGISTER
DATA NACK STOP
0 XXh 0 XXh 0 XXh 0 . . . XXh 1 0 -> 1
Table 3.8 Alert Response Address Protocol
START
ALERT
RESPONSE
ADDRESS RD ACK DEVICE
ADDRESS NACK STOP
1 -> 0 0001_100b 1 0 YYYY_YYYb 1 0 -> 1
Dual RPM-Based PWM Fan Controller
Datasheet
Revision 1.3 (05-18-11) 16 SMSC EMC2302
DATASHEET
Chapter 4 Product Description
The EMC2302 is an SMBus compliant fan controller with two programmable frequency PWM fan
drivers. The fan drivers can be operated using two modes: the RPM-based Fan Speed Control
Algorithm or the direct fan drive setting.
Figure 4.1 shows a system diagram of the EMC2302.
4.1 Fan Control Modes of Operation
The EMC2302 has two modes of o peration for e ach fan driver. Each mode of operation u ses the Ramp
Rate control and Spin Up Routine.
1. Direct Setting Mode - in this mode of operation, the user directly controls the fan drive setting.
Updating the Fan D river Setting Register (see Section 5.7) will instantly update the PWM fan drive.
Ramp Rate control is optional and enabled via the EN_RRC bits.
Whenever the Direct Setting Mode is enab led, the current drive will be changed to what was
last written into the Fan Driver Setting Register.
2. Fan Speed Control Mode (FSC) - in this mode of operation, the user determines a target
tachometer count and the PWM drive setting is aut omatically updated to ac hieve this target speed.
The algorithm uses the Spin Up Routine and has user definable ramp rate controls.
This mode is enabled setting the EN_ALGO bit in the Fan Configuration Register.
Figure 4.1 System Diagram of EMC2302
EMC2302
SMCLK
SMDATA
ALERT#
VDD
3.3V
MCU
TACH1 tachometer
PWM1 Drive
Circuit
TACH2 tachometer
PWM2 Drive
Circuit
32.768KH z Clock
Input or Output CLK
GND
Dual RPM-Based PWM Fan Controller
Datasheet
SMSC EMC2302 17 Revision 1.3 (05-18-11)
DATASHEET
4.2 PWM Fan Driver
The EMC2302 supports 2 PWM output drivers. Each output driver can be configu red to operate as an
open-drain (default) or push-pull driver and each driver can be configured with normal or inverse
polarity. Additionally, the PWM frequencies are independently programmable with ranges from 9.5Hz
to 26kHz in four programmable frequency bands.
4.3 RPM-based Fan Speed Control Algorithm (FSC)
The EMC2302 includes 2 RPM-based Fan Speed Control Algorithms. Each algorithm operates
independently an d controls a separate fan driver. Each algorithm is controlled manually (by setting the
target fan speed).
This fan control algorithm uses Proportional, Integral, and Derivative terms to automatically approach
and maintain the system’s desired fan speed to an accuracy directly proportional to the accuracy of
the clock source.
The desired tachometer count is set by the user inputting the desired number of 32.768kHz cycles that
occur per fan revolution. This is done by manually setting the TACH Target Register. The user may
change the target count at any time. Th e user may also set the target count to FFh in order to disable
the fan driver for lower current operation.
For example, if a desired RPM rate for a 2-pole fan is 3000 RPMs, then the user would input the
hexidecimal equivalent of 1296 (51h in the TACH Target Register ). This numb er represents the number
of 32.768KHz cycles that would occur during the time it takes the fan to complete a single revolution
when it is spinning at 3000RPMs.
Table 4.1 Fan Controls Active for Operating Mode
DIRECT SETTING MODE FSC MODE
Fan Driver Setting (read / write) Fan Driver Setting (read only)
EDGES[1:0] EDGES[1:0]
(Fan Configuration)
- RANGE[1:0]
(Fan Configuration)
UPDATE[2:0]
(Fan Configuration) UPDATE[2:0]
(Fan Configuration)
LEVEL
(Spin Up Configuration) LEVEL
(Spin Up Configuration)
SPINUP_TIME[1:0]
(Spin Up Configuration) SPINUP_TIME[1:0]
(Spin Up Configuration)
Fan Step Fan Step
- Fan Minimum Drive
Valid TACH Count Valid TACH Count
- TACH Target (read / write)
TACH Reading TACH Reading
- DRIVE_FAIL_CNT[1:0] and Drive Band Fail Registers
Dual RPM-Based PWM Fan Controller
Datasheet
Revision 1.3 (05-18-11) 18 SMSC EMC2302
DATASHEET
The EMC2302’s RPM-based Fan Speed Control Algorithm has programmable configuration settings
for parameters such as ramp-rate control and spin up conditions. The fan driver automatically detects
and attempts to alleviate a stalled/stuck fan condition while also asserting the ALERT# pin. The
EMC2302 works with fans that operate up to 16,000 RPMs and provide a valid tachometer signal.
The fan controller will function either with an externally supplied 32.768kHz clock source or with it’s
own internal 32kHz oscillator de pending on the required accuracy. The EMC2302 offers a clock output
that enables additional devices to be slaved to the same clock source.
4.3.1 Programming the RPM-based Fan Speed Control Algorithm
The RPM-based Fan Speed Control Algorithm is disabled upon device power up. The following
registers control the algorithm. The EMC2302 fan control registers are pre-loaded with defaults that
will work for a wide variety of fans so only the TACH Target Register is required to set a fan speed.
The other fan control registers can be used to fine-tune the algorithm behavior based on application
requirements.
Note that steps 1 - 6 are optional and need only be performed if the default settings do not provide
the desired fan response.
1. Set the Spin Up Configuration Register to the Spin Up Level and Spin Time desired.
2. Set the Fan Step Register to the desired step size.
3. Set the Fan Minimum Drive Register to the minimum drive value that will maintain fan operation.
4. Set the Update Time and Edges options in the Fan Configuration Register.
5. Set the Valid TACH Count Register to the highest tach count that indicates the fan is spinning.
Refer to AN17.4 RPM to TACH Counts Conversion for examples and tables for supported RPM
ranges (500, 1k, 2k, 4k).
6. Set the TACH Target Register to the desired tachometer count.
7. Enable the RPM-based Fan Speed Control Algorithm by setting the EN_ALGO bit.
4.4 Tachometer Measurement
The tachometer measurement circuitry is used in conjunction with the RPM-based Fan Speed Control
Algorithm to update the fan driver output. Additionally, it can be used in Direct Setting mode as a
diagnostic for host based fan control.
This method monitors the TACHx signal in real time. It constantly updates the tachometer
measurement by reporting the numb er of clocks between a user programmed number of e dges on the
TACHx signal (see Table 5.12).
The tachometer measurement provides fast response times for the RPM-based Fan Speed Control
Algorithm and the data is presented as a count value that represents the fan RPM period.
APPLICATION NOTE: The tachometer measurement method works independently of the drive settings. If the
device is put into Direct Setting and the fan drive is set at a level that is lower than the fan
can operate (including zero drive), then the tachometer measurement may signal a Stalled
Fan condition and assert an interrupt.
4.4.1 Stalled Fan
A Stalled fan is detected if the tach counter exceeds the user-programmab le Valid TACH Count setting.
If a stall is detected, the device will flag the fan as stalled and trigger an interrupt.
If the RPM-based Fan Speed Control Algorithm is enabled, the algorithm will automatically attempt to
restart the fan until it detects a valid tachometer level or is disabled.
Dual RPM-Based PWM Fan Controller
Datasheet
SMSC EMC2302 19 Revision 1.3 (05-18-11)
DATASHEET
The FAN_STALL Status bit indicates that a stalled fan was detected. This bit is checked conditionally
depending on the mode of operation.
Whenever the Direct Setting Mode or the Spin Up Routine is enabled, the FAN_STALL interrupt
will be masked for the duration of the programme d Spin Up Time (see Table 5.22) to allow the fan
to reach a valid speed without generating unnecessary interrupts.
In Direct Setting Mode, whenever the TACH Reading Register value exceeds the Valid TACH Count
Register setting, the FAN_STALL status bit will be set.
When using the RPM-based Fan Speed Control Algorithm, the stalled fan condition is checked
whenever the Update Time is met and the fan drive setting is updated. It is no t a conti nuous check.
4.4.2 Aging Fan or Invalid Drive Detection
This is useful to detect aging fan conditions (where the fan’s natural maximum speed degrades over
time) or a speed setting that is faster than the fan is capable of. The EMC2302 contains circuitry that
detects that the programmed fan speed can be reached by the fan. If the target fan speed cannot be
reached within a user defined band of tach counts at maximum drive, the DRIVE_FAIL status bits are
set and the ALERT# pin is asserted.
4.5 CLK Pin
The CLK pin has multiple functionality as determined by the settings of the Configuration register.
4.5.1 External Clock
The EMC2302 allows the user to choose between supplying an external 32.768kHz clock or use of
the internal 32kH z oscillator to measure the tachomet er signal. This clock source is used by the RPM-
based Fan Speed Control Algorithm to calculate the current fan speed. This fan controller accuracy is
directly proportional to the accuracy of the clock source.
When this function is used, the external clock is driven into the device via the CLK pin.
4.5.2 Internal Clock
Alternately, the EMC2302 may be configured to use its internal clock as a clock output to drive other
fan driver devices. When configured to operate in this mode, the device uses its internal clock for
tachometer reading and drives the CLK pin using a push-pull driver.
4.6 Spin Up Routine
The EMC2302 also contains programmable circuitry to control the spin up behavior of the fan driver
to ensure proper fan operation.
The Spin Up Routine is initiated in Direct Setting mode when the setting value changes from 00h to
anything else.
When the Fan Speed Control Algorithm is enabled , the Spin Up Routine is initi ated under the following
conditions:
1. The TACH Target Register value changes fro m a value of FFh to a value that is less than the Valid
TACH Count (see Section 5.15).
2. The RPM-based Fan Speed Control Algorithm’s measured TACH Reading Register value is greater
than the Valid TACH Count setting.
Dual RPM-Based PWM Fan Controller
Datasheet
Revision 1.3 (05-18-11) 20 SMSC EMC2302
DATASHEET
When the Spin Up Routine is operating, the fan driver is set to full scale (optional) for one quarter of
the total user defined spin up time. For the remaining spin up time, the fan driver output is set at a
user defined level (30% through 65% drive).
After the Spin Up Routine has finished, the EMC2302 measures the TACHx signal. If the measured
TACH Reading Register value is higher than the Valid TACH Count Register setting, the FAN_SPIN
status bit is set and the Spin Up Routine will automatically attempt to restart the fan.
Figure 4.2 shows an example of the Spin Up Routine in response to a programmed fan speed change
based on the first condition above.
4.7 Ramp Rate Control
The Fan Driver can be configured with automatic ramp rate control. Ramp rate control is accomplish ed
by adjusting the drive output settings based on the Maximum Fan Step Register settings and the
Update Time settings.
If the RPM-based Fan Speed Control Algorithm is used, then this ramp rate control is automatically
used. The user programs a maximum step size for the fan drive setting and an update time. The
update time varies from 100ms to 1.6s while the fan drive maximum step can vary from 1 count to 31
counts.
When a new fan drive setti ng is entered, the delta from the next fan drive setting and th e previous fan
drive setting is determined. If this delta is greater than the Max Step settin gs, then the fan drive setting
is incrementally adjusted every 100ms to 1.6s as determined by the Update Time until the target fan
drive setting is reached. See Figure 4.3.
Figure 4.2 Spin Up Routine
100%
(optional)
30% through 65%
Algorithm controlled drive
Fan Step
Spin Up Time
¼ o f S p in U p T ime
Update Time
Target Count
Changed Target Count
Reached
New Target Count
Prev Target
Count = FFh
Check TA CH
Dual RPM-Based PWM Fan Controller
Datasheet
SMSC EMC2302 21 Revision 1.3 (05-18-11)
DATASHEET
4.8 Watchdog Timer
The EMC2302 contains an internal Watchdog Timer for all fan drivers. The Watchdog timer monitors
the SMBus traffic for signs of activity and works in two different modes based upon device operation.
These modes are Power Up Operation and Continuous Operation as described below.
For either mode of operation, if four (4) seconds elapse without activity detected by the host, then the
watchdog will be triggered and the following will occur:
1. The WATCH status bit will be set.
2. The fan driver will be set to full scale drive. It will remain at full scale drive until it is disabled.
3. The ALERT# pin is asserted.
APPLICATION NOTE: When the Watchdog timer is activated, the Fan Speed Control Algorithm is automatically
disabled. Disabling the Watchdog will not automatically set the fan drive nor re-activate the
Fan Speed Control Algorithm. This must be done manually.
4.8.1 Power Up Operation
The Watchdog Timer only starts immediately after power-up. Once it has been triggered or deactivated,
it will not restart although it can be configured to operate in Continu ous operation. W hile the Watchdog
timer is active, the device will not check for a Stalled Fan condition.
Figure 4.3 Ramp Rate Control
Previous
Setting
Next Desired
Setting
Max
Step
Max
Step
Update
Time Update
Time
Setting Changed
Dual RPM-Based PWM Fan Controller
Datasheet
Revision 1.3 (05-18-11) 22 SMSC EMC2302
DATASHEET
In the Power Up Operation, the Watchdog Timer is disabled by any of the following actions:
1. Writing the Fan Setting Register will disable the Watchdog Timer.
2. Enabling the RPM-based Fan Speed Control Algorith m by setting the EN_ALGO bi t will disable the
Watchdog Timer. The fan dr iver will be set based on the RPM-based Fan Speed Control Algo rithm.
Writing any other configuration registers will not disable the Watchdog Timer upon power up.
4.8.2 Continuous Operation
When configured to operate in Continuous Operation, the Watchdog timer will start immediately. The
timer will be reset by any access (read or write) to the SMBu s register set. The four second Watchdog
timer will restart upon completion of SMBus activity.
Dual RPM-Based PWM Fan Controller
Datasheet
SMSC EMC2302 23 Revision 1.3 (05-18-11)
DATASHEET
Chapter 5 Register Set
5.1 Register Map
The following registers are accessible through the SMBus Interface. All register bits marked as ‘-’ will
always read ‘0’. A write to these bits will have no effect.
Tab le 5.1 EMC2302 Register Set
ADDR R/W REGISTER
NAME FUNCTION DEFAULT
VALUE LOCK PAGE
Configuration and control
20h R/W Configuration Configures the clocking and watchdog
functionality 40h SWL Page 25
24h R-C Fan Status Stores the status bits for the RPM-
based Fan Speed Control Algorithm 00h No Page 26
25h R-C Fan Stall Status Stores status bits associated with a
stalled fan 00h No Page 26
26h R-C Fan Spin Status Stores status bits associated with a
spin-up failure 00h No Page 26
27h R-C Drive Fail Status Stores status bits associated with drive
failure 00h No Page 26
29h R/W Fan Interrupt
Enable Register Controls the masking of interrupts on all
fan related channels 00h No Page 27
2Ah R/W PWM Polarity
Config Configures Polarity of all PWM drivers 00h No Page 28
2Bh R/W PWM Output
Config Configures Outpu t type of PWM drivers 00h No Page 28
2Dh R/W PWM Base
Frequency Selects the base frequency for PWM
output 2 00h No Page 28
Fan 1 Control Registers
30h R/W Fan 1 Setting
Always displays the most recent fan
driver input setting for Fan 1. If the
RPM-based Fan Speed Control
Algorithm is disabled, allows direct user
control of the fan driver.
00h No Page 29
31h R/W PWM 1 Divide Stores the divide ratio to set the
frequency for Fan 1 01h No Page 30
32h R/W Fan 1
Configuration 1 Sets configuration values for the RPM-
based Fan Speed Control Algorithm for
the Fan 1 driver 2Bh No Page 30
33h R/W Fan 1
Configuration 2 Sets additional configurati on values for
the Fan 1 driver 28h SWL Page 32
Dual RPM-Based PWM Fan Controller
Datasheet
Revision 1.3 (05-18-11) 24 SMSC EMC2302
DATASHEET
35h R/W Gain 1 Holds the ga in terms used by the RPM-
based Fan Speed Control Algorithm for
the Fan 1 driver 2Ah SWL Page 33
36h R/W Fan 1 Spin Up
Configuration Sets the configuration values for Spin
Up Routine of the Fan 1 driver 19h SWL Page 34
37h R/W Fan 1 Max Step Sets the maximum change per update
for the Fan 1 driver 10h SWL Page 35
38h R/W Fan 1 Minimum
Drive Sets the minimum drive value for the
Fan 1 driver 66h
(40%) SWL Page 36
39h R/W Fan 1 Valid TACH
Count Holds the tachometer reading that
indicates Fan 1 is spinning properly F5h SWL Page 36
3Ah R/W Fan 1 Drive Fail
Band Low Byte Store s the number of Tach cou nts used
to determine how the actual fan speed
must match the target fan spee d at full
scale drive
00h SWL Page 37
3Bh R/W Fan 1 Drive Fail
Band High Byte 00h SWL
3Ch R/W TACH 1 Target
Low Byte Holds the target tachometer reading low
byte for Fan 1 F8h No Page 37
3Dh R/W TACH 1 Target
High Byte Holds the target tachometer reading
high byte for Fan 1 FFh No Page 37
3Eh R TACH 1 Rea ding
High Byte Holds the tachometer reading high byte
for Fan 1 FFh No Page 38
3Fh R TACH 1 Reading
Low Byte Holds the tachometer reading low byte
for Fan 1 F8h No Page 38
Fan 2 Control Registers
40h R/W Fan 2 Setting
Always displays the most recent fan
driver input setting for Fan 2. If the
RPM-based Fan Speed Control
Algorithm is disabled, allows direct user
control of the fan driver.
00h No Page 29
41h R/W PWM 2 Divide Stores the divide ratio to set the
frequency for Fan 2 01h No Page 30
42h R/W Fan 2
Configuration1 Sets configuration values for the RPM-
based Fan Speed Control Algorithm for
Fan 2 2Bh No Page 30
43h R/W Fan 2
Configuration 2 Sets additional configurati on values for
the Fan 2 driver 28h SWL Page 32
45h R/W Gain 2 Holds the ga in terms used by the RPM-
based Fan Speed Control Algorithm for
Fan 2 2Ah SWL Page 33
46h R/W Fan 2 Spin Up
Configuration Sets the configuration values for Spin
Up Routine of the Fan 2 driver 19h SWL Page 34
47h R/W Fan 2 Max Step Sets the maximum change per update
for Fan 2 10h SWL Page 35
Table 5.1 EMC2302 Register Set (continued)
ADDR R/W REGISTER
NAME FUNCTION DEFAULT
VALUE LOCK PAGE
Dual RPM-Based PWM Fan Controller
Datasheet
SMSC EMC2302 25 Revision 1.3 (05-18-11)
DATASHEET
During Power-On-Reset (POR), the default val ues are stored in the registers. A POR is initiated when
power is first applied to the part and the voltage on the VDD supply surpasses the POR level as
specified in the electrical characteristics. Any reads to undefined registers will return 00h. Writes to
undefined registers will not have an effect.
5.1.1 Lock Entries
The Lock Column describes the locking mechanism, if any, used for individual registers. All SWL
registers are Software Locked and therefore made read-only when the LOCK bit is set.
5.2 Configuration Register
48h R/W Fan 2 Minimum
Drive Sets the minimum drive value for the
Fan 2 driver 66h
(40%) SWL Page 36
49h R/W Fan 2 Valid TACH
Count Holds the tachometer reading that
indicates Fan 2 is spinning properly F5h SWL Page 36
4Ah R/W Fan 2 Drive Fail
Band Low Byte Store s the number of Tach cou nts used
to determine how the actual fan speed
must match the target fan spee d at full
scale drive
00h SWL Page 37
4Bh R/W Fan 2 Drive Fail
Band High Byte 00h SWL
4Ch R/W TACH 2 Target
Low Byte Holds the target tachometer setting low
byte for Fan 2 F8h No Page 37
4Dh R/W TACH 2 Target
High Byte Holds the target tachometer setting high
byte for Fan 2 FFh No Page 37
4Eh R TACH 2 Rea ding
High Byte Holds the tachometer reading high byte
for Fan 2 FFh No Page 38
4Fh R TACH 2 Reading
Low Byte Holds the tachometer reading low byte
for Fan 2 F8h No Page 38
Lock Register
EF R/W Software Lock Locks all SWL registers 00h SWL Page 39
Revision Registers
FDh R Product ID Stores the unique Product ID 36h No Page 39
FEh R Manufacturer ID Stores the Manufacturer ID 5Dh No Page 40
FFh R Revision Revision 80h No Page 40
Table 5.2 Configuration Register
ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT
20h R/W Configuration MASK DIS_TO WD_EN - - - DR_EXT_
CLK USE_
EXT_
CLK 40h
Table 5.1 EMC2302 Register Set (continued)
ADDR R/W REGISTER
NAME FUNCTION DEFAULT
VALUE LOCK PAGE
Dual RPM-Based PWM Fan Controller
Datasheet
Revision 1.3 (05-18-11) 26 SMSC EMC2302
DATASHEET
The Configuration Register controls the basic functionality of the EMC2302. The bits are described
below. The Configuration Register is software locked.
Bit 7 - MASK - Blocks the ALERT# pin from being asserted.
‘0’ (default) - The ALERT# pin is unmasked. If any bit in the status registers is set, the ALERT#
pin will be asserted (unless individually masked via the Fan Interrupt Enable Register).
‘1’ - The ALERT# pin is masked and will not be asserted.
Bit 6 - DIS_TO - Disables the SMBus timeout function for the SMBus client (if enabled).
‘0’ - The SMBus timeout function is enabled.
‘1’ (default) - The SMBus timeout function is disabled allowing the device to be fully I2C complia nt.
Bit 5 - WD_EN - Enables the Watchdog timer (see Section 4.8) to operate in Continuous Mode.
‘0’ (default) - The Watchdog timer does not operate continuously. It will function upon power up and
at no other time (see Section 4.8.1).
‘1’ - The Watchdog timer operates continuously as described in Section 4.8.2.
Bit 1 - DR_EXT_CLK - Enables the internal tachometer clock to be driven out on the CLK pin so that
multiple devices can be synced to the same source.
‘0’ (default) - The CLK pin acts as a clock input.
‘1’ - The CLK pin acts as a clock output and is a push-pull driver.
Bit 0 - USE_EXT_CLK - Enables the EMC2302 to use a clock present on the CLK pin as the
tachometer clock. If the DR_EXT_CLK bit is set, then this bit is ignored and the device will use the
internal oscillator.
‘0’ (default) - The EMC2302 will use its internal oscillator for all Tachometer measurements.
‘1’ - The EMC2302 will use the oscillator presented on the CLK pin for all Tachometer
measurements.
5.3 Fan Status Registers
The Fan Status registers contain the status bits associated with each fan driver.
5.3.1 Fan Status - 24h
The Fan Status register indicates that one or both of the fan drivers has stalled or failed or that the
Watchdog Timer has expired (see Section 4.8).
Table 5.3 Fan Status Registers
ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT
24h R-C Fan Status WATCH - - - - DRIVE_
FAIL FAN_
SPIN FAN_
STALL 00h
25h R-C Fan Stall
Status - - - - - -
FAN2_
STALL FAN1_
STALL 00h
26h R-C Fan Spin
Status - - - - - -
FAN2_
SPIN FAN1_
SPIN 00h
27h R-C Fan Drive
Fail Status ----- -
DRIVE_
FAIL2 DRIVE_
FAIL1 00h
Dual RPM-Based PWM Fan Controller
Datasheet
SMSC EMC2302 27 Revision 1.3 (05-18-11)
DATASHEET
Bit 7 - WATCH - Indicates that the Watchdog Timer has expired. When set, each fan is driven to 100%
duty cycle and will remain at 100% duty cycle until they are programmed. This bit is cleared when it
is read.
Bit 2 - DRIVE_FAIL - Indicates that one or both fan drivers cannot meet the programmed fan speed
at maximum PWM duty cycle. This bit is set when any bit in the Fan Drive Fail Status register is set
and cleared when all bits in the Fan Drive Fail Status register are cleared.
Bit 1 - FAN_SPIN - Indicates that one or both fan drivers cannot spin up. This bit is set when any bit
in the Fan Spin Status register is set and cleared when all of the bits in the Fan Spin Status register
are cleared.
Bit 0 - FAN_STALL - Indicates that one or both fan drivers have stalled. This bit is set when any bit in
the Fan Stall Status register is set and cleared when all of the bits in the Fan Stall Status register are
cleared.
5.3.2 Fan Stall Status - 25h
The Fan Stall Status register indicates which fan driver has detected a stalled condition (see
Section 4.4.1). All bits are cleared upon a read if the error condition has been removed.
Bit 1 - FAN2_STALL - Indicates that Fan 2 has stalled.
Bit 0 - FAN1_STALL - Indicates that Fan 1 has stalled.
5.3.3 Fan Spin Status - 26h
The Fan Spin Status register indicates which fan driver has failed to spin-up (see Section 4.6). All bits
are cleared upon a read if the error condition has been removed.
Bit 1 - FAN2_SPIN - Indicates that Fan 2 has failed to spin up.
Bit 0 - FAN_SPIN - Indicates that Fan 1 has failed to spin up.
5.3.4 Fan Drive Fail Status - 27h
The Fan Drive Fail Status register indicates which fan driver cannot drive to the programmed speed
even at 100% duty cycle (see Section 4.4.2 and Section 5.12). All bits are cleared upon a read if the
error condition has been removed.
Bit 1 - DRIVE_FAIL2 - Indicates that Fan 2 cannot reach its programmed fan speed even at 100% duty
cycle. This may be due to an aging fan or invalid programming.
Bit 0 - DRIVE_FAIL1 - Indicates that Fan 1 cannot reach its programmed fan speed even at 100% duty
cycle. This may be due to an aging fan or invalid programming.
5.4 Fan Interrupt Enable Register
The Fan Interrupt Enable controls the masking for each Fan channel. When a channel is enabled, it
will cause the ALERT# pin to be asserted when an error condition is detected.
Table 5.4 Fan Interrup t Enable Register
ADDRR/WREGISTERB7B6B5B4 B3 B2 B1B0DEFAULT
29h R/W Fan
Interrupt
Enable ---- - -
FAN2_
INT_EN FAN1_
INT_EN 00h
Dual RPM-Based PWM Fan Controller
Datasheet
Revision 1.3 (05-18-11) 28 SMSC EMC2302
DATASHEET
Bit 1 - FAN2_INT_EN - Allows Fan 2 to assert the ALERT# pin if an error is detected.
Bit 0 - FAN1_INT_EN - Allows Fan 1 to assert the ALERT# pin if an error condition is detected.
‘0’ (default) - An error condition on Fan X will not cause the ALERT# pin to be asserted, however
the status registers will be updated normally.
‘1’ - An error condition (Stall, Spin Up, Drive Fail) on Fan X will cause the ALERT# pin to be
asserted.
5.5 PWM Configuration Registers
The PWM Config registers control the output type and polarity of all PWM outputs.
5.5.1 PWM Polarity Config - 2Ah
Bit 1 - POLARITY2 - Determines the polarity of PWM 2.
Bit 0 - POLARITY1 - Determines the polarity of PWM 1.
‘0’ (default) - the Polarity o f the PWM driver is normal. A drive setting of 00h will cause the ou tput
to be set at 0% duty cycle and a drive setting of FFh will cause the output to be set at 100% duty
cycle.
‘1’ - The Polarity of the PWM driver is inverted. A drive setting of 00h will cause the output to be
set at 100% duty cycle and a drive setting of FFh will cause the output to be set at 0% duty cycle.
5.5.2 PWM Output Config - 2Bh
Bit 1 - PWM2_OT - Determines the output type of PWM 2 driver.
Bit 0 - PWM1_OT - Determines the output type of the PWM 1 driver.
‘0’ (default) - The PWM 1 output is configured as an open drain output.
‘1’ - The PWM 1 output is configured as a push-pull output.
5.6 PWM Base Frequency Register
Table 5.5 PWM Configuration Registers
ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT
2Ah R/W PWM Polarity
Config --- - - -
POLARITY
2POLARITY
100h
2Bh R/W PWM Output
Config - - - - - - PWM2_OT PWM1_OT 00h
Table 5.6 PWM Base Frequency Register
ADDRR/WREGISTERB7B6B5B4B3B2B1B0DEFAULT
2Dh R/W PWM Base
Frequency ----
PWM_
BASE
2_1
PWM_
BASE
2_0
PWM_
BASE
1_1
PWM_
BASE
1_0 00h
Dual RPM-Based PWM Fan Controller
Datasheet
SMSC EMC2302 29 Revision 1.3 (05-18-11)
DATASHEET
The PWM Base Frequency register determines the base frequency that is used with the PWM Divide
register to determine the final PWM fre quency. Each PW M frequency is set by the base frequency and
its respective divide ratio (see Section 5.8).
Controls the base frequency of PWM drivers 1-3 2
Bits 3-2 - PWM_BASE2[1:0] - Determines the base frequency of the PWM2 driver.
Bits 1-0 - PWM_BASE1[1:0] - Determines the base frequency of the PWM1 driver.
5.7 Fan Setting Registers
The Fan Setting reg ister always disp lays the current setting of the respective fan dri ver. Reading from
any of the registers will report the current fan speed setting of the appropriate fan driver regardless of
the operating mode. Therefore it is possible that reading from this register will not report data that was
previously written into this register.
While the RPM-based Fan Speed Control Algorithm is active, the register is read only. Writing to the
register will have no effect and the data will not be stored.
The contents of the register represent the we ighting of each bit in determining the final output voltage.
The output drive for a PWM output is given by Equation [1].
Table 5.7 PWM_BASEx[1:0] Bit Decode
PWM_BASEX[1:0]
BASE FREQUENCY10
0 0 26.00kHz (default)
0 1 19.531kHz
1 0 4,882Hz
1 1 2,441Hz
Table 5.8 Fan Driver Setting Registers
ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT
30h R/W Fan 1 Setting 128 64 32 16 8 4 2 1 00h
40h R/W Fan 2 Setting 128 64 32 16 8 4 2 1 00h
[1]
Drive VALUE
255
---------------------
⎝⎠
⎛⎞
100%×=
Dual RPM-Based PWM Fan Controller
Datasheet
Revision 1.3 (05-18-11) 30 SMSC EMC2302
DATASHEET
5.8 PWM Divide Registers
The PWM Divide registers determine the final frequency of the respective PWM F an Driver. Each driver
base frequency is divided by the value of the respective PWM Divide Register to determine the final
frequency. The duty cycle settings are not affected by these settings, only the final frequency of the
PWM driver. A value of 00h will be decoded as 01h.
5.9 Fan Configuration 1 Registers
The Fan Configur ation 1 registers control the gen eral operation of the RPM-based Fan Speed Control
Algorithm used for the respective Fan Driver.
Bit 7 - EN_ALGOx - enables the RPM-based Fan Speed Control Algorithm.
‘0’ - (default) the control circuitry is disabled and the fan driver output is determined by the Fan
Driver Setting Register.
‘1’ - the control circuitry is enabled and the Fan Driver output will be automatically updated to
maintain the programmed fan speed as indicated by the TACH Target Register.
Bits 6- 5 - RANGEx[1:0] - Adjusts the range of reported and programmed tachometer reading values.
The RANGE bits determine the weighting of all TACH values (including the Valid TACH Count, TACH
Target, and TACH reading) as shown in Table 5.11.
Table 5 .9 PWM Divide Registers
ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT
31h R/W Fan 1 Divide 128 64 32 16 8 4 2 1 01h
41h R/W Fan 2 Divide 128 64 32 16 8 4 2 1 01h
Table 5.10 Fan Configuration 1 Registers
ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT
32h R/W Fan 1
Configuration 1 EN_
ALGO1 RANGE1[1:0] EDGES1[1:0] UPDATE1[2:0] 2Bh
42h R/W Fan 2
Configuration 1 EN_
ALGO2 RANGE2[1:0] EDGES2[1:0] UPDATE2[2:0] 2Bh
Table 5.11 Range Decode
RANGEX[1:0] REPORTED MINIMUM
RPM TACH COUNT
MULTIPLIER10
005001
0 1 1000 (default) 2
1 0 2000 4
1 1 4000 8
Dual RPM-Based PWM Fan Controller
Datasheet
SMSC EMC2302 31 Revision 1.3 (05-18-11)
DATASHEET
Bits 4-3 - EDGESx[1:0] - determines the minimum number of edges that must be detected on the
TACHx signal to determine a single rotation. A typical fan measured 5 edges (for a 2-pole fan). For
more accurate tachometer measurement, the min imum number of edges measured may be increased.
Increasing the number of edges measured with respect to the number of poles of the fan will cause
the TACH Reading registers to indicate a fan speed that is higher or lower than the actual speed. In
order for the FSC Algorithm to operate correctly, the TACH Target must be updated by the user to
accommodate this shift. The Effective Tach Mu ltiplier shown in Table 5.12 is used as a direct multiplier
term that is applied to the Actual RPM to achieve the Reported RPM. It should only be applied if the
number of edges measured does not match the number of edges expected based on the number of
poles of the fan (which is fixed for any given fan).
Contact SMSC for recommended settings when using fans with more or less than 2 poles.
Bit 2-0 - UPDATEx[2:0] - determines the base time between fan driver updates. The Update Time,
along with the Fan Step Register, is used to control the ramp rate of the drive response to provide a
cleaner transition of the actual fan operation as the desired fan speed changes. The Update Time is
set as shown in Table 5.13.
Table 5.12 Minimum Edges for Fan Rotation
EDGESX[1:0] MINIMUM TACH
EDGES NUMBER OF FAN POLES
EFFECTIVE TACH
MULTIPLIER (BASED ON 2
POLE FANS)10
0 0 3 1 pole 0.5
0 1 5 2 poles (default) 1
1 0 7 3 poles 1.5
1 1 9 4 poles 2
Table 5.13 Update Time
UPDATEX[2:0]
UPDATE TIME 21 0
00 0 100ms
00 1 200ms
01 0 300ms
0 1 1 400ms (default)
10 0 500ms
10 1 800ms
1 1 0 1200ms
1 1 1 1600ms
Dual RPM-Based PWM Fan Controller
Datasheet
Revision 1.3 (05-18-11) 32 SMSC EMC2302
DATASHEET
5.10 Fan Configuration 2 Registers
The Fan Configuration 2 register control the tachometer measurement and advanced features of the
RPM-based Fan Speed Control Algorithm.
Bit 6 - EN_RRCx - Enables ramp rate control when the corresponding fan driver is operated in the
Direct Setting Mode.
‘0’ (default) - Ramp rate control is disabled. When the fan driver is operating in Direct Setting mode,
the fan setting will instantly transition to the next programmed setting.
‘1’ - Ramp rate control is enabl ed. When the fan driver is opera ting in Direct Setting mode, the fan
drive setting will follow the ramp rate controls as determined by the Fan Step and Update Time
settings. The maximum fan drive setting step is capped at the Fan Step setting and is updated
based on the Update Time as given by Table 5.13.
Bit 5 - GLITCH_ENx - Disables the low pass glitch filter that removes high frequency noise injected
on the TACHx pin.
‘0’ - The glitch filter is disabled.
‘1’ (default) - The glitch filter is enabled.
Bits 4 - 3 - DER_OPTx[1:0] - Control some of the advanced options that affect the derivative portion
of the RPM-based Fan Speed Control Algorithm as shown in Table 5.15.
Table 5.14 Fan Configuration 2 Registers
ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT
33h R/W Fan 1
Configuration 2 -EN_
RRC1 GLITCH_
EN1 DER_OPT1 [1:0] ERR_RNG1[1:0] - 28h
43h R/W Fan 2
Configuration 2 -EN_
RRC2 GLITCH_
EN2 DER_OPT2 [1:0] ERR_RNG2[1:0] - 28h
Table 5.15 Derivative Options
DER_OPTX[1:0]
OPERATION10
0 0 No derivative options used
01
Basic derivative. The derivative of the error from
the current drive setting and the target is added
to the iterative Fan Drive Register setting (in
addition to proportional and integral terms)
(default)
10
Step derivative. The derivative of the error from
the current drive setting and the target is added
to the iterative Fan Drive Register setting and is
not capped by the Fan Step Register.
11
Both the basic deri vative and the step derivative
are used effectively causing the derivative term to
have double the effect of the derivative term.
Dual RPM-Based PWM Fan Controller
Datasheet
SMSC EMC2302 33 Revision 1.3 (05-18-11)
DATASHEET
Bit 2 - 1 - ERR_RNGx[1:0] - Control some of the advanced options that affect the error window. When
the measured fan spe ed is within the programmed error windo w around the target speed, then the fan
drive setting is not updated. The algorithm will continue to monitor the fan speed and calculate
necessary drive setting changes based on the error; however, these changes are ignored.
5.11 Gain Registers
The Gain registers store the gain terms used by the proportional and integral portions of each of the
RPM-based Fan Speed Control Algorithms. These gain terms are used as the KD, KI, and KP gain
terms in a classic PID control solution.
Bits 5 - 4 - GAINDX[1:0] - Controls the derivative gain term used by the FSC algorithm as shown in
Table 5.18.
Bits 3-2 - GAINIX[1:0] - Controls the integral gain term used by the FSC algorithm as shown in
Table 5.18.
Bits 1-0 - GAINP[1:0] - Controls the proportional gain term used by the FSC algorithm as shown in
Table 5.18.
Table 5.16 Error Range Options
ERR_RNGX[1:0]
OPERATION10
0 0 0 RPM (default)
0 1 50 RPM
1 0 100 RPM
1 1 200 RPM
Table 5.17 Gain Registers
ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT
35h R/W Gain 1
Register - - GAIND1[1:0] GAINI1[1:0] GAINP1[1:0] 2Ah
45h R/W Gain 2
Register - - GAIND2[1:0] GAINI2[1:0] GAINP2[1:0] 2Ah
Table 5.18 Gain Decode
GAIND OR GAINP OR GAINI [1:0]
RESPECTIVE GAIN FACTOR10
00 1x
01 2x
1 0 4x (default)
Dual RPM-Based PWM Fan Controller
Datasheet
Revision 1.3 (05-18-11) 34 SMSC EMC2302
DATASHEET
5.12 Fan Spin Up Configuration Registers
The Fan Spin Up Configuration registers control the settings of Spin Up Routine. The Fan Spin Up
Configuration registers are software locked.
Bit 7 - 6 - DRIVE_FAIL_CNTx[1:0] - Determines how many update cycles are used for the Drive Fail
detection function as shown in Table 5.20. This circuitry determines whether the fan can be driven to
the desired tach target.
Bit 5 - NOKICKx - Determines if the Spin Up Routine will drive the fan to 100% duty cycle for 1/4 of
the programmed spin up time before driving it at the programmed level.
‘0’ (default) - The Spin Up Routine w ill drive the fa n driver to 100% for 1/4 o f the programmed spi n
up time before reverting to the programmed spin level.
‘1’ - The Spin Up Routine will not drive the fan driver to 100%. It will set the drive at the
programmed spin level for the entire duration of the programmed spin up time.
Bits 4 - 2 - SPIN_LVLx[2:0] - Determines the final drive level that is used by the Spin Up Routine as
shown in Table 5.21.
11 8x
Table 5.19 Fan Spin Up Configuration Registers
ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT
36h R/W Fan 1 Spin Up
Configuration DRIVE_FAIL_
CNT1 [1:0] NOKICK1 SPIN_LVL1[2:0] SPINUP_TIME
1 [1:0] 19h
46h R/W Fan 2 Spin up
Configuration DRIVE_FAIL_
CNT2 [1:0] NOKICK2 SPIN_LVL2[2:0] SPINUP_TIME
2 [1:0] 19h
Table 5.20 DRIVE_FAIL_CNT[1:0] Bit Decode
DRIVE_FAIL_CNTX[1:0]
NUMBER OF UPDATE PERIODS10
0 0 Disabled - the Drive Fail detecti on circuitry is disabled (default)
01
16 - the Drive Fail detection circuitry will count for 16 update
periods
10
32 - the Drive Fail detection circuitry will count for 32 update
periods
11
64 - the Drive Fail detection circuitry will count for 64 update
periods
Table 5.18 Gain Decode (continued)
GAIND OR GAINP OR GAINI [1:0]
RESPECTIVE GAIN FACTOR10
Dual RPM-Based PWM Fan Controller
Datasheet
SMSC EMC2302 35 Revision 1.3 (05-18-11)
DATASHEET
Bit 1 -0 - SPINUP_TIMEx[1:0] - determines the maximum Spin Time that the Spin Up Routine will run
for (see Section 4.6). If a valid tachometer measurement is not detected before the Spin Time has
elapsed, an interrupt will be generated. When the RPM-based Fan Speed Control Algorithm is active,
the fan driver will attempt to re-start the fan immediately after the end of the last spin up attempt.
The Spin Time is set as shown in Table 5.22.
5.13 Fan Max Step Registers
Table 5.21 Spin Level
SPIN_LVLX[2:0]
SPIN UP DRIVE LEVEL210
0 0 0 30%
0 0 1 35%
0 1 0 40%
0 1 1 45%
1 0 0 50%
1 0 1 55%
1 1 0 60% (default)
1 1 1 65%
Table 5.22 Spin Time
SPINUP_TIMEX[1:0]
TO TA L SP I N U P TI M E10
0 0 250 ms
0 1 500 ms (default)
1 0 1 sec
1 1 2 sec
Table 5.23 Fan Max Step Registers
ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT
37h R/W Fan 1 Max
Step - - 32 16 8 4 2 1 10h
47h R/W Fan 2 Max
Step - - 32 16 8 4 2 1 10h
Dual RPM-Based PWM Fan Controller
Datasheet
Revision 1.3 (05-18-11) 36 SMSC EMC2302
DATASHEET
The Fan Max Step registers, along with the Update Time, control the ramp rate of the fan driver
response calculated by the RPM-based Fan Speed Control Algorithm. The value of the register
represents the maximum step size each fan driver will take between update times (see Section 5.9).
When the FSC algorithm is enabled, Ramp Rate control is automatically used. When the FSC is not
active, then Ramp Rate control can be enabled by asserting the EN_RRC bit (see Section 5.10).
APPLICATION NOTE: The UPDATE bits and Fan Step Register settings operate independently of the RPM-based
Fan Speed Control Algorithm and will always limit the fan drive setting. That is, if the
programmed fan drive setting (either as determined by the RPM-based Fan Speed Control
Algorithm or by manual settings) exceeds the current fan drive setting by greater than the
Fan Step Register setting, the EMC2302 will limit the fan drive change to the value of the
Fan Step Register. It will use the Update Time to determine how often to update the drive
settings.
APPLICATION NOTE: If the Fan Speed Control Algorithm is used, the default settings in the Fan Configuration 2
Register will cause the maximum fan step settings to be ignored.
The Fan Max Step registers are software locked.
5.14 Fan Minimum Drive Registers
The Fan Minimum Drive registers store the minimum drive setting for each RPM-based Fan Speed
Control Algorith m. The RPM-based Fan Speed Control Algorithm wil l not drive the fan at a level lower
than the minimum drive unless the target Fan Speed is set at FFh (see Section 5.17).
During normal operation, if the fan stops for any reason (including low drive), the RPM-based Fan
Speed Control Algorithm will attempt to restart the fan. Setting the Fan Minimum Drive Register to a
setting that will maintain fan operation is a useful way to avoid potential fan oscillations as the control
circuitry attempts to drive it at a level that cannot support fan operation.
The Fan Minimum Drive Registers are software locked.
5.15 Valid TACH Count Registers
Table 5.24 Minimum Fan Drive Registers
ADDRR/WREGISTERB7B6B5B4B3B2B1B0DEFAULT
38h R/W Fan 1
Minimum
Drive 128643216 8 4 2 1 66h
(40%)
48h R/W Fan 2
Minimum
Drive 128643216 8 4 2 1 66h
(40%)
Table 5.25 Valid TACH Count Registers
ADDRR/WREGISTERB7B6B5B4B3B2B1B0DEFAULT
39h R/W Valid T ACH
Count 1 4096 2048 1024 512 256 128 64 32 F5h
49h R/W Valid T ACH
Count 2 4096 2048 1024 512 256 128 64 32 F5h
Dual RPM-Based PWM Fan Controller
Datasheet
SMSC EMC2302 37 Revision 1.3 (05-18-11)
DATASHEET
The Valid TACH Count registers store the maximum TACH Reading Register value to indicate that
each fan is spinning properly. The value is referenced at the end of the Spin Up Routine to determine
if the fan has started operating and d ecide if th e device needs to retry. See Equation [2] in Section 5.18
for translating the count to an RPM.
If the TACH Reading Register value exceeds the Valid TACH Count Register (indicating that the Fan
RPM is below the threshold set by this count), then a stalled fan is detected. In this condition, the
algorithm will automatically begin its Spin Up Routine.
If a TACH Target setting is set above the Valid TACH Count setting, then that setting will be ignored
and the algorithm will use the current fan drive setting.
The Valid TACH Count registers are software locked.
5.16 Fan Drive Fail Band Registers
The Fan Drive Fail Band Registers store the number of tach counts used by the Fan Drive Fail
detection circuitry. This circuitry is activated when the fan drive setting high byte is at FFh. When it is
enabled, the actual measured fan speed is compared against the target fan speed. These registers
are only used when the FSC is active.
This circuitry is used to indicate that the target fan speed at full drive is higher than the fan is actually
capable of reaching. If the measured fan speed does not exceed the target fan speed minus the Fan
Drive Fail Band Register settings for a period of time longer than set by the DRIVE_FAIL_CNTx[1:0]
bits, then the DRIVE_FAIL status bit will be set and an interrupt generated.
5.17 TACH Target Registers
Table 5.26 Fan Drive Fail Band Registers
ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT
3Ah R/W Fan 1 Drive
Fail Band
Low Byte 16 8 4 2 1 - - - 00h
3Bh R/W Fan 1 Drive
Fail Band
High Byte 4096 2048 1024 512 256 128 64 32 00h
4Ah R/W Fan 2 Drive
Fail Band
Low Byte 16 8 4 2 1 - - - 00h
4Bh R/W Fan 2 Drive
Fall Band
High Byte 4096 2048 1024 512 256 128 64 32 00h
Table 5.27 TACH Target Registers
ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT
3Ch R/W TACH Target
1 Low Byte 168421- - - F8h
3Dh R/W TACH Target
1 High Byte 4096 2048 1024 512 256 128 64 32 FFh
Dual RPM-Based PWM Fan Controller
Datasheet
Revision 1.3 (05-18-11) 38 SMSC EMC2302
DATASHEET
The TACH Target Registers hold the target tachometer value that is maintained by the RPM-based
Fan Speed Control Algorithm.
The value in the TACH Target Registers will always reflect the current TACH Target value.
If one of the algorithms is enabled, setting the TACH Target Register to FFh will disable the fan driver
(set the fan drive setting to 0%). Setting the TACH Target to any other value (from a setting of FFh)
will cause the algorithm to invoke the Spin Up Routine after which it will function normally.
The Tach Target is not applied until the high byte is written. Once the high byte is written, the current
value of both high and low bytes will be used as the next Tach target.
5.18 TACH Reading Registers
The TACH Reading Registers’ contents describe the current tachometer reading for each of the fans.
By default, the data represents the fan speed as the number of 32kHz clock periods that occur for a
single revolution of the fan.
Equation [2] sho ws the detailed conversion from TACH measurement (COUNT) to RPM while Equation
[3] shows the simplified translation of TACH Reading Register count to RPM assuming a 2-pole fan,
measuring 5 edges, with a frequency of 32.768kHz. T hese equ ations ar e solved and tabulated for ease
of use in AN17.4 RPM to TACH Counts Conversion.
Whenever the high byte register is read, the corresponding low byte data will be loaded to internal
shadow registers so that when the low byte is read, the data will always coincide with the previously
read high byte.
4Ch R TACH Target
2 Low Byte 168421- - - F8h
4Dh R/W TACH Target
2 High Byte 4096 2048 1024 512 256 128 64 32 FFh
Table 5.28 TACH Reading Registers
ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT
3Eh R Fan 1 TACH 4096 2048 1024 512 256 128 64 32 FFh
3Fh R Fan 1 TACH
Low Byte 168421- - - F8h
4Eh R Fan 2 TACH 4096 2048 1024 512 256 128 64 32 FFh
4Fh R Fan 2 TACH
Low Byte 168421- - - F8h
Table 5.27 TACH Target Registers (continued)
ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT
Dual RPM-Based PWM Fan Controller
Datasheet
SMSC EMC2302 39 Revision 1.3 (05-18-11)
DATASHEET
5.19 Software Lock Register
The Software Lock Register controls the software locking of critical registers. This register is software
locked.
Bit 0 - LOCK - this bit acts on all registers that are designated SWL. When this bit is set, the locked
registers become read only and cannot be updated.
‘0’ (default) - all SWL registers can be updated normally.
‘1’ - all SWL registers cannot be updated and a hard-reset is required to unlock them.
5.20 Product ID Register
The Product ID Register contains a unique 8-bit word that identifies the product.
where:
[2]
poles = number of poles of the fan
(typically 2)
fTACH = the tachometer
measurement frequency (typically
32.768kHz)
n = number of edges measured
(typically 5 for a 2 pole fan)
m = the multiplier defined by the
RANGE bits [3]
COUNT = TACH Reading Register
value (in decimal)
Tab le 5.29 Software Lock Register
ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT
EFh R/W Software
Lock -------LOCK00h
Table 5.30 Product ID Register
ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT
FDh R Product ID 0 0 1 1 0 1 1 0 36h
RPM 1
poles()
-------------------- n1()
COUNT 1
m
-----
×
----------------------------------fTACH 60×××=
Dual RPM-Based PWM Fan Controller
Datasheet
Revision 1.3 (05-18-11) 40 SMSC EMC2302
DATASHEET
5.21 Manufacturer ID Register
The Manufacturer ID Register contains an 8-bit word that identifies SMSC.
5.22 Revision Register
The Revision Register contains an 8-bit word that identifies the die revision.
Table 5.31 Manufacturer ID Reg iste r
ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT
FEh R Manufacturer ID 0 1 0 1 1 1 0 1 5Dh
Table 5.32 Revision Register
ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT
FFh R Revision 1 0 0 0 0 0 0 0 80h
Dual RPM-Based PWM Fan Controller
Datasheet
SMSC EMC2302 41 Revision 1.3 (05-18-11)
DATASHEET
Chapter 6 Typical Operating Curves
The following Typical Operating Curves are included.
Supply Current vs. Temperature
Supply Current vs. Supply Voltage
Fan TACH Accuracy vs. Temperature
Fan TACH Accuracy vs. Supply Voltage
PWM output frequency vs. Supply Voltage
PWM output frequency vs. Temperature
FSC Operation
Supp ly Current vs. Ambi e nt Temperature
250
300
350
400
450
500
-50 0 50 100 150
Temperature (C)
Supply Current (uA)
Supply Current (uA)
Ambient Temperature (°C)
Supply Current vs. Suppl y Volta ge
250
300
350
400
450
500
2.95 3.05 3.15 3.25 3.35 3.45 3.55 3.65
Supply Voltage (V)
Supply Current (uA)
Supply Current (uA)
Supply Voltage (V)
T achometer Measurement Accuracy vs. Ambient Temperature
-1
-0.8
-0.6
-0.4
-0.2
0
0.2
0.4
0.6
0.8
1
-50 0 50 100 150
Temperautre (C)
Tach Measurement Accuracy (%
Ambient Temperature (°C)
Tach Mea s urement Accura cy (%)
T achometer Measurem ent Accuracy vs. Supply Voltage
-1
-0.8
-0.6
-0.4
-0.2
0
0.2
0.4
0.6
0.8
1
2.95 3.05 3.15 3.25 3.35 3.45 3.55 3.65
Supply Voltage (V)
Tach Measurement Accuracy (%
Tach Measurement Accuracy (%)
Dual RPM-Based PWM Fan Controller
Datasheet
Revision 1.3 (05-18-11) 42 SMSC EMC2302
DATASHEET
PWM Frequency vs. Amb ient Temperature
VDD = 3.3V, Base Frequncy = 26Khz
25000
25200
25400
25600
25800
26000
26200
26400
26600
26800
27000
-50 0 50 100 150
T emper at ure ( C )
Ambient Temperature (°C)
PWM Frequency (Hz)
PWM Frequency vs. Supply Voltage
T A = 25C , Base Frequncy = 26K hz
25000
25200
25400
25600
25800
26000
26200
26400
26600
26800
27000
2.95 3.05 3.15 3.25 3.35 3.45 3.55 3.65
Supply Voltage (V)
PWM Frequency (Hz)
PWM
Output
10x
Zoom on
PWM
Output
Spin Time = 1.0s; Spin Level = 55%; Updated Time = 200ms;
RPM Target from 0 RPM -> 8000 RPM @ time t = 0
FSC Alg o r ith m Spin Up Ro utine
t = 0 Duty Cycle Measured = 53.8%
PWM
Output
10x
Zoom on
PWM
Output
Spin Time = 1.0s; Spin Level = 50%; UpdateTime = 200ms;
RPM Target from 0 RPM -> 8000 RPM @ time t = 0
FSC Algorithm Spin Up Routine – NoKick
t = 0 Duty Cycle Measured = 50%
PWM
Output
10x
Zoom on
PWM
Output
Update Time = 200ms; Max Step = 16 PWM counts
RPM Ta rget from 0 R P M -> 8000 RPM @ time t = 0
FSC Algorithm PWM Ramping
Spin Up Routine Ends – begins normal
operation
Update Time ends, PWM duty cycle changed
Update Time ends, PWM duty
cycle changed
Duty Cycle
Measured
Dual RPM-Based PWM Fan Controller
Datasheet
SMSC EMC2302 43 Revision 1.3 (05-18-11)
DATASHEET
Chapter 7 Package Drawing
7.1 EMC2302 Package Information
Figure 7.1 EMC2302 Package Drawing - 10-Pin MSOP
A
A2
A1
SEATING PLANE
SIDE VIEW
ccc C
GAUGE PLANE
H
3-D VIEW
TOP VIEW
C
3
2
END VIEW
4
35
DETAIL "A"
NOTES:
1. ALL DIM ENSIONS ARE IN MILLIM ETER.
2. TOLERANCE ON THE TRUE POSITION O F EACH LEAD IS ± 0.04 mm AT MAXIMUM MATERIAL
CON DITION.
3. PAC KAGE BODY D IM ENSI O NS "D " AND " E1" D O NOT IN CL UDE MOLD /IN T ERLEA D PROTRU SIONS
OR FLASH. MAXIMUM MOLD PROTR USIONS OR FLASH IS 0.15 mm ( 0.006 INCHES) PER END AND
SIDE. D IM ENSIONS "D" AND "E1" ARE DET ERMINED AT THE OUTERMOST EXTREMES OF THE
PLASTIC BODY, INCLUDING ANY MISMAT CH BETWEEN TOP AN D BOTTOM PLASTIC BODY. THEY
ARE DETERMINED AT DATUM PLANE "H" .
4. D IMENSIONS "b" AND "c" APPLY T O THE FLAT SECTION OF THE LEAD BETWEEN 0.08 mm AND
0.15 mm FROM T HE LEAD TIP.
5. D ETAILS OF T HE PIN 1 IDENTIFIER ARE OPTIONAL, BUT MUST BE LOC ATED WITHIN THE ZONE
INDICATED.
A I NITIA L RELE ASE 3/29/05 S. K.ILI EV
c
SEE D ETA IL " A"
eD
E1 E
P IN 1 IDENTIFIER
AREA (D /2 X E1 /2)
10X b
L
(0.95)
0.25
-
DI M AND TOL P ER ASME Y14.5M - 1994
FINISH
MATERIAL
DECIMAL
X.X
X.XX
X.XXX
80 A R KA Y D RIVE
HAUPPAUGE, NY 11788
USA
AN G U LAR
PRINT W IT H "SCALE TO FIT"
DO NOT S CALE DRA WIN G
CH ECKED
APPR OVED
NAME
DRAWN
DWG NUM BE R
SC ALE
TITLE
DAT E
STD COMPLIANCE
UNLESS OTHE RWIS E SPECIFIE D
DIM ENSI ONS ARE IN MILLIMETERS
AN D TOLERANCES ARE:
THIR D ANG L E PRO J ECTION
REV
SHEET
REVISION DESCRIPTION
REV ISIO N HISTORY
RELEAS ED BYDATE
PACKAG E OUTLINE
10 PIN TSSOP, 3x3 MM BODY, 0.50 MM PITCH
±1 °
-
-
±0.1
±0.05
±0.025
S.K.ILIEV
S.K.ILIEV
S.K.ILIEV
3/29/05
3/29/05
1:1
3/29/05
MO-10-TSSOP-3x3
JEDEC: MO-18 7 1 OF 1
A
C
SEATING PLANE
4
Dual RPM-Based PWM Fan Controller
Datasheet
Revision 1.3 (05-18-11) 44 SMSC EMC2302
DATASHEET
7.2 Package Markings
Figure 7.2 EMC2302 Package Markings
BOTTOM
LINE: 1-T – Device Num ber
LINE: 2-T Version, Revision, Country Code (VRCC)
ALL TOP LINES CENTER
HORIZONTAL ALIGNMENT
PB-FREE/GREEN SYMBOL
(M a tte Sn )
2x 1.5pt
TOP
e3
PIN 1
LINE: 1-B – Date Code (YYWW)
LINE: 2-B – First 3 Digits of Lot Number
3x 1.5pt
PIN 1
LINE: 3-B – Last 4 Digits of Lot Number
23 02
VRCC
YYWW
123
456a
Dual RPM-Based PWM Fan Controller
Datasheet
SMSC EMC2302 45 Revision 1.3 (05-18-11)
DATASHEET
Chapter 8 Datasheet Revision History
Table 8.1 Customer Revision History
REVISION LEVEL & DATE SECTION/FIGURE/ENTRY CORRECTION
Rev. 1.3 (05-18-11) Section 4.8, "Watchdog
Timer" The ALERT# pin is asserted when the watchdog is
triggered.
Section 5.2, "Configuration
Register" Corrected description for MASK bit. Changed “If
any bit in either status register is set, the ALERT#
pins will be asserted (unless individually masked
via the Mask Register)” to “If any bit in the status
registers is set, the ALERT# pin will be asserted
(unless individually masked via the Fan Interrupt
Enable Register)”.
Rev. 1.2 (03-22-10) Table 2.3, "SMBus Electrical
Specifications" Updated SMBus Data Hold Time spec to 0 us
Rev. 1.1 (10-12-09) Table 2.2, "Electrical
Specifications" Tachometer Setting Accuracy max was changed
from +/-3% to +/-2%.
Chapter 6, Typical
Operating Curves Added typical operating curves
Ordering Information Added EMC2302-2 for 2nd SMBus address
Rev. 1.0 (05-15-09) Initial release of datasheet