E2CA E2CA Special-Purpose Proximity Sensor E2CA Threaded Cylindrical Inductive Sensor with Separate Amplifier Provides Precision Linear Analog Output and a Discrimination Output Linear 4 to 20 mA output for target to sensor distance Position measurements accurate to 0.0006 mm with 0.05% full scale resolution Adjustable setpoint controls switching output rated 100 mA is NO/NC selectable Amplifier has power ON, target detected, and discrimination output indicators AC amplifier has universal voltage rating 90 to 264 VAC Sensing Supply voltage Output 90 to 264 VAC, 50/60 Hz amplifier or 10 to 30 VDC amplifier DC amplifier rated 10 to 30 VDC Sensors available in standard 8, 12, 18, 30 mm sizes with sensing distances up to 10 mm 1.5, 2, 5, 10 mm 4 to 20 mA 100 mA, 40 VDC Ordering Information SENSOR Sensor type Shielded 3 m (9.8 ft) cable E2CA-X1R5A E2CA-X2A E2CA-X5A E2CA-X10A 5 m (16.4 ft) cable E2CA-X1R5A-5M E2CA-X2A-5M E2CA-X5A-5M E2CA-X10A-5M Size M8 M12 M18 M30 Nominal sensing distance 0.3 to 1.5 mm (0.01 to 0.06 in) 0.4 to 2.0 mm (0.02 to 0.08 in) 1 to 5 mm (0.04 to 0.20 in) 2 to 10 mm (0.08 to 0.39 in) Part number AMPLIFIER Required sensor Part number E2CA-X1R5A/-5M E2CA-X2A/-5M E2CA-X5A/-5M E2CA-X10A/-5M AC power supply E2CA-AN4C E2CA-AN4D E2CA-AN4E E2CA-AN4F DC power supply E2CA-AL4C E2CA-AL4D E2CA-AL4E E2CA-AL4F Outputs Linear output, 4 to 20 mA; Switching output, selectable NO or NC transistor ACCESSORIES Description Mounting brackets for sensors Sockets for amplifiers Part number Fits M8 size sensors Y92E-B8 Fits M12 size sensors Y92E-B12 Fits M18 size sensors Y92E-B18 Fits M30 size sensors Y92E-B30 Combination bottom surface and track mounting socket with screw terminals P2CF-11 Back mounting socket with screw terminals for panel mount applications P3GA-11 Circuit board socket with solder terminals PL-11 (This table continues on the following page.) 69 E2CA E2CA Specifications Table -- continued from previous page Description Part number Panel mounting adapter for amplifier Y92F-30 Protective covers for amplifier Y92A-48 Mounting track Hard plastic cover protects amplifiers from dust, dirt and water drip Soft plastic cover protects amplifier from dust, dirt and water drip Y92A-48D DIN rail, 50 cm (1.64 ft) length PFP-50N DIN rail, 1 m (3.28 ft) length PFP-100N End plate PFP-M Spacer PFP-S REPLACEMENT PARTS Description Part number Mounting hardware includes one pair of metal nuts and washers Fits M8 size sensors (supplied with each sensor) M8-MHWS Fits M12 size sensors (supplied with each sensor) M12-MHWS Fits M18 size sensors (supplied with each sensor) M18-MHWS Fits M30 size sensors (supplied with each sensor) M30-MHWS Specifications SENSOR Part number E2CA-X1R5A/-5M Sensor type Inductive Body Size Type M8 E2CA-X2A/-5M E2CA-X5A/-5M E2CA-X10A/-5M M12 M18 M30 E2CA-AL4D or E2CA-AN4D E2CA-AL4E or E2CA-AN4E E2CA-AL4F or E2CA-AN4F Shielded Required amplifier E2CA-AL4C or E2CA-AN4C Detectable object type Metallic objects Effective maximum sensing distance (with standard target) 1.5 mm (0.06 in) 2 mm (0.08 in) 5 mm (0.20 in) 10 mm (0.39 in) Usable sensing range (with standard target) 0.3 to 1.5 mm (0.01 to 0.06 in) 0.4 to 2.0 mm (0.02 to 0.08 in) 1 to 5 mm (0.04 to 0.20 in) 2 to 10 mm (0.08 to 0.39 in) Standard target size (mild steel, L x W x H) 8 x 8 x 1 mm (0.32 x 0.32 x 0.04 in) 12 x 12 x 1 mm (0.47 x 0.47 x 0.04 in) 18 x 18 x 1 mm (0.71 x 0.71 x 0.04 in) 30 x 30 x 1 mm (1.18 x 1.18 x 0.04 in) 5 kHz 3 kHz Two lock washers and M18 nuts included. Bracket Y92E-B18 optional. Two lock washers and M30 nuts included. Bracket Y92E-B30 optional. Response frequency 10 kHz Indicators Not provided Materials Housing Nickel-plated brass Sensing face Plastic, acrylonitoryl butadiene styrene Cable sheath Plastic, polyethylene Mounting Two lock washers and M8 nuts included. Bracket Y92E-B8 optional. Connections Prewired 2-conductor shielded cable: 3 m (9.8 ft) length (E2CA-XA) 5 m (16.4 ft) length (E2CA-XA-5M) Weight with cable 40 g (1.4 oz.) Enclosure ratings Approvals UL 70 60 g (2.1 oz.) 140 g (5.0 oz.) 160 g (5.7 oz.) -- NEMA 1, 4, 6, 12, 13 IEC 144 IP67 UL -- CSA Two lock washers and M12 nuts included. Bracket Y92E-B12 optional. -- Ambient operating temperature -25 to 70C (-13 to 158 F) -10 to 55C (14 to 131F) Vibration 10 to 55 Hz, 1.5 mm (0.06 in) double amplitude 10 to 25 Hz, 2 mm (0.08 in) double amplitude Shock Approx. 50 G Approx. 10 G E2CA E2CA AMPLIFIER Part number Supply voltage E2CA-A4C AC types E2CA-A4D E2CA-A4E E2CA-A4F E2CA-X5A E2CA-X10A 5 kHz 3 kHz 90 to 264 VAC, 50/60 Hz (E2CA-AN4) DC types 10 to 30 VDC (E2CA-AL4) AC types Current consumption DC types 60 mA max. (E2CA-AN4) 70 mA max. (E2CA-AL4) Required sensor E2CA-X1R5A Linear Output range output Resolution characteristics Linearity 4 to 20 mA 0.05% to full scale 2.0% of full scale 1.5% of full scale Response frequency Adjustment E2CA-X2A 10 kHz 2.0% of full scale 4 mA Adjustment to 4 mA at 20% of effective maximum detecting distance 20 mA Adjustment to 20 mA at effective maximum detecting distance Switching Operation mode output Detecting distance characteristics sensitivity NO or NC, switch selectable Adjustable (within sensor's "Usable Detecting Range") Differential travel Fixed, 1 to 5% of detecting distance Control Type output Max. load Transistor, SPST 100 mA, 40 VDC Max. on-state 2 VDC voltage drop Circuit protection Response frequency 3 kHz Switching output short-circuit Not provided DC power supply reverse polarity Provided Weld-field immunity Not provided RFI immunity Indicators Materials 1.5 kHz 1 kHz Not provided Power ON (POWER), Linear Range (SPAN), and Switching Output ON (OPER) Housing Plastic Mounting Requires P2CF-11, P3GA-11 or PL11 sockets (not included); order separately from Accessories. Adapter Y92F-30 for panel mounting the amplifier (optional); order separately from Accessories. Connections Plated steel screw terminals (P2CF-11 and P3GA-11 sockets); Solder terminals (PL11 socket) Weight without AC types socket DC types 250 g (8.8 oz.) Enclosure ratings Approvals 120 g (4.2 oz.) UL -- NEMA 1 IEC 144 IP40 UL -- CSA -- Ambient operating temperature -10 to 55C (-14 to 131F) Vibration 10 to 25 Hz, 2 mm (0.08 in) double amplitude Shock Approx. 10 G 71 E2CA E2CA Nomenclature AMPLIFIER POWER indicator (Red LED) Illuminates when energized Mode selector switch Selector switch for cable length compensation SENSITIVITY adjustment Adjusts the target setpoint distance for switching output OPER. indicator (Red LED) Illuminates when the target is present within the range from the minimum sensing distance to the target setpoint distance SPAN indicator (Green LED) Indicates the linear area of the output current Linear output current adjustment (20 mA) Linear output current adjustment (4 mA) Operation FUNCTION -- AMPLIFIER Classification O U T P U T I N D I C A T O R S A D J U S T M E N T S Function Linear output An analog 4 to 20 mA output signal proportional to the distance from the target to the face of the sensor within the range of the 4 mA linear setpoint to the 20 mA setpoint. Switching output A 100 mA, 40 VDC rated transistor output (separate power source required) adjustable within the range of the 4 mA linear setpoint and 20 mA linear setpoint. Power ON Red LED illuminated when amplifier is connected to power source and energized. Operation Red LED illuminated when the target is present within the range from the minimum sensing distance to the target setpoint distance. Span Green LED illuminated when the target is present within the range of the 4 mA linear setpoint and the 20 mA linear setpoint. Cable length selector switch Set to the length of cable (3 or 5 meters) supplied on the sensor head. 4 mA linear adjustment Used to set the analog output at 4 mA when the target is at 20% of the rated sensing distance. Adjustment method 1. 20 mA linear adjustment Used to set the analog output at 20 mA when the target is at 100% of the rated sensing distance. Adjustment method 1. Sensitivity Used to set the target distance that turns on the switching output. Mode selector switch Determines the logic of the switching output circuit. In the NO position, the target turns on when the target is present between the minimum sensing distance and the target setpoint distance. In the NC position, the switching output turns on when the target is beyond the target setpoint distance. TIMING CHART 100% rated distance Distance of target Target setpoint distance 20% rated distance Linear output 20 mA 4 mA SPAN indicator Mode selector * NO position Switching output Operator indicator * NC position Switching output Operator indicator 72 E2CA E2CA LINEAR OUTPUT ADJUSTMENTS Linearity Adjustment Method 2 Choose one of the two adjustment methods for setting the LINEARITY adjuster. Adjustment of the 4 mA and 20 mA LINEARITY adjusters must be performed with the standard target at positions of 20% and 100% of the rated detecting distance away from the sensor. 1. Set the standard target at 20% of the rated detecting distance away from the sensor. Linearity Adjustment Method 1 1. Connect an ammeter across terminals 1 and 2. The illustration shows the sensor connected to an amplifier through socket P2CF-11. 2. Turn the 4 mA LINEARITY adjuster counterclockwise so that the SPAN indicator remains OFF. Then slowly turn the adjuster clockwise until the indicator illuminates. Stop turning the adjuster at the position where the SPAN indicator illuminates. 3. Set the standard target at the rated detecting distance away from the sensor. 2. Place the standard target at 20% of the rated detecting distance away from the sensor unit. 3. Turn the 4 mA LINEARITY adjuster slowly clockwise (to increase the output current) or counterclockwise (to decrease the output current). Set the adjuster to a position that reads 4 mA output on the ammeter. 4. Slowly turn the 20 mA LINEARITY adjuster clockwise until the SPAN indicator goes OFF. Then turn the adjuster counterclockwise until the indicator illuminates. Stop turning the adjuster when the SPAN indicator illuminates. SENSITIVITY ADJUSTMENTS Place the standard target at the specified position. If the target moves in parallel with the surface of the sensor unit, make the adjustment after determining the position using the following procedure. 4. Place the standard target at the rated detecting distance. 1. Adjust the linear output according to Adjustment Method 1 or 2. 5. Turn the 20 mA LINEARITY adjuster slowly clockwise (to increase the output current) or counterclockwise (to decrease the output current). Set the adjuster to a position that reads 20 mA output on the ammeter. 2. Calculate detecting distance X using the following formula: S X= S = setting distance 0.8 3. Adjust the distance between the sensor and the object to be detected to distance X. 6. To fine tune the adjustment accuracy of the output current, repeat the adjustment steps for 4 mA and 20 mA LINEARITY adjusters. Slowly turn the SENSITIVITY adjuster clockwise (toward HIGH) and stop turning when the OPER. indicator illuminates. Move the target to confirm that the OPER. indicator illuminates when the object to be detected is at the specified position and that the indicator goes OFF when the target is moved away from that position. If the target moves in parallel with the surface of the sensor unit, place the sensor at distance S. 73 E2CA E2CA SELECTOR SWITCHES Selection of Operation Modes Compensation for Different Cable Lengths OUTPUT NO NC The output transistor turns ON when the target is detected. OUTPUT The output transistor turns ON when the target is not being detected. NO NC Set the CABLE selector switch to the required position according to the length of the sensor cable being used: 3 m (9.8 ft) or 5 m (16.4 ft). CABLE 3m 5m CABLE 3m 5m To use sensors with 3 m (9.8 ft) cable length. To use sensors with 5 m (16.4 ft) cable length. Dimensions Unit: mm (inch) SENSORS M8 Size E2CA-X1R5A, E2CA-X1R5A-5M 13 (0.51) across flats M12 Size E2CA-X2A, E2CA-X2A-5M 18 (0.71) 18 (0.71) 17 (0.67) across flats 8.5 (0.33) dia. 12.5 (0.49) dia. M30 Size E2CA-X10A, E2CA-X10A-5M M18 Size E2CA-X5A, E2CA-X5A-5M 24 (0.94) across flats 36 (1.42) across flats 30 (1.18) 27 (1.06) 18.5 (0.73) dia. 30.5 (1.20) dia. AMPLIFIERS E2CA-AL4, E2CA-AN4 48 (1.89) 93.7 (3.69) 72.5 (2.85) 44.8 (1.76) 74 15 (0.59) 40 (1.57) 37 (1.46) E2CA E2CA SOCKETS FOR AMPLIFIERS P2CF-11 Track-Mount Socket with Screw Terminals Terminal Arrangement (top view) 35.4 (1.39) 70 (2.76) max. Mounting Holes 40 0.2 (1.57 0.008) Note: The socket can be mounted on DIN rail track or surface mounted using two through holes. 50 (1.97) max. 31 (1.22) max. P3GA-11 Back-Mounting Socket with Screw Terminals Terminal Arrangement (bottom view) 26.6 45 (1.05) (1.77) 45 (1.77) PL11 Circuit Board Socket with Solder Terminals 3.5 (0.14) Terminal Arrangement (bottom view) 30 (1.18) dia. 51 40 (2.01) (1.57) max. Mounting Holes 31 (1.22) dia. hole 40 0.3 (1.57 0.01) 35 (1.38) max. MOUNTING TRACK AND ACCESSORIES PFP-100N/PFP-50N DIN Rail Track PFP-M End Plate PFP-S Spacer Y92A-48, Y92A-48D OPTIONAL PROTECTIVE COVERS FOR AMPLIFIERS Hard plastic cover Y92-48 and soft plastic cover Y92A-48D snap onto the front of the amplifier to protect it from dust, dirt and water drip. The Y92A-48 hard plastic cover projects 4 mm from the front of the amplifier. Y92A-48D soft plastic cover fits snugly over the front. 75 E2CA E2CA Y92F-30 OPTIONAL PANEL MOUNTING ADAPTER FOR AMPLIFIERS Panel cutout 45 +0.5 -0 (1.77 +0.02 ) -0 58 (2.28) 45 +0.5 -0 (1.77 +0.02 ) -0 48 (1.89) Note: Recommended panel thickness is 1 to 3.2 mm. 100.4 (3.95) OPTIONAL MOUNTING BRACKETS FOR SENSORS Part number Drawing dimension Y92E-B8 180.2 10 max. A B C D 18 8 dia. E F Applicable sensor models 28 max. M4 x 20 E2CA-X1R5A, bolt E2CA-X1R5A-5M Y92E-B12 240.2 12.5 max. 20 12 dia. 37 max. M4 x 25 E2CA-X2A, bolt E2CA-X2A-5M Y92E-B18 320.2 17 max. 30 18 dia. 47 max. M5 x 32 E2CA-X5A, bolt E2CA-X5A-5M Y92E-B30 450.2 17 max. 50 30 dia. 60 max. M5 x 50 E2CA-X10A, bolt E2CA-X10A-5M Engineering Data OPERATING DISTANCE VS. OUTPUT CURRENT 76 M8 Size Sensor E2CA-X1R5A M12 Size Sensor E2CA-X2A M18 Size Sensor E2CA-X5A M30 Size Sensor E2CA-X10A E2CA E2CA DETECTING DISTANCE VS. LINEARITY (SQUARE AND RECTANGULAR OBJECTS) M8 Size Sensor E2CA-X1R5A M12 Size Sensor E2CA-X2A M18 Size Sensor E2CA-X5A M30 Size Sensor E2CA-X10A DETECTING DISTANCE VS. LINEARITY (CYLINDRICAL OBJECTS) M8 Size Sensor E2CA-X1R5A M12 Size Sensor E2CA-X2A M18 Size Sensor E2CA-X5A 77 E2CA E2CA Installation OUTPUT CIRCUIT DIAGRAM CONNECTIONS BETWEEN SENSOR AND AMPLIFIER Note: The illustrations show the terminal arrangement viewed from the rear of the socket that is coupled to the amplifier. DC Amplifier and Sensor AC Amplifier and Sensor CONNECTION OF LINEAR OUTPUT Note: The illustration shows the linear output connected to a resistive load. * Resistance R when E2CA-AL4 is used: 300 max. at 24 V/150 max. at 12 V Resistance R when E2CA-AN4 is used: 300 max. 78 E2CA E2CA CONNECTION OF SWITCHING OUTPUT A transistorized photocoupler output is used for the switching output of the E2CA-A4 amplifier unit, which offers flexibility for switching different loads and power supply polarity selection. Type of load Direct load drive: Relay or solenoid Solid-state load Sink load (photocoupler) Voltage load (logic circuit) E2CA-A4 amplifiers MOUNTING SENSORS L Effects of Surrounding Metals Shielded E2CA proximity sensors may be mounted flush with a metallic panel. Be sure to provide a minimum distance as shown in the table to prevent the sensor from being affected by metallic objects other than the target. Drawing dimension d (dia.) D m Sensor model E2CA-X1R5A E2CA-X2A mm inch mm inch E2CA-X5A mm inch E2CA-X10A mm inch L 0 0 0 0 0 0 0 0 d (dia.) 8 0.32 12 0.47 18 0.71 30 1.18 D 0 0 0 0 0 0 0 0 m 4.5 0.18 6 0.24 15 0.59 30 1.18 Mutual Interference To prevent mutual interference between two sensors, be sure to space the two sensors at a distance greater than that shown in the table. Drawing dimension Sensor model E2CA-X1R5A E2CA-X2A mm inch mm inch E2CA-X5A mm inch E2CA-X10A mm inch A 20 0.79 30 1.18 50 1.97 100 3.94 B 15 0.59 20 0.79 35 1.38 70 2.76 MOUNTING AMPLIFIERS Tightening Force Track-Mount Installation Using P2CF-11 Socket Do not exceed the maximum torque listed in the table. Sensor model Maximum torque kg-cm The P2CF-11 socket has two hooks that secure the E2CA amplifier to the socket. Be sure to allow at least 20 mm (0.79 in) clearance above and below the socket to gain access and to release the hooks for servicing and maintenance. The P2CF-11 socket may also be used for surface mounting the amplifier using the two through holes. in-lbs E2CA-X1R5A 20 17 E2CA-X2A 60 52 E2CA-X5A 150 130 E2CA-X10A 400 346 79 E2CA E2CA Panel-Mount Installation Using Y92F-30 Adapter and P3GA-11 Socket Insert the E2CA amplifier through the panel cutout. Push the Y92F-30 adapter from the rear of the amplifier as far forward toward the panel as possible. Then tighten the two retaining screws. Wire the P3GA-11 socket, then push it onto the rear of the amplifier. To release the adapter, lift the tab at the rear of the adapter. Several E2CA amplifiers may be panel mounted close together using Y92F-30 adapter as shown here. When mounting two or more amplifiers in a vertical line, arrange the adapters so that their molded tabs are positioned on the right and left sides. When mounting two or more amplifiers in a horizontal line, arrange the adapters so that their molded tabs are positioned on the top and bottom sides. Panel Cutout for Side-by-Side Mounting of Two Amplifiers NOTE: DIMENSIONS ARE SHOWN IN MILLIMETERS. To convert millimeters to inches divide by 25.4. OMRON ELECTRONICS LLC. OMRON ON-LINE OMRON CANADA, INC. One East Commerce Drive Schaumburg, IL 60173 Global - http://www.omron.com USA - http://www.omron.com/oei Canada - http://www.omron.com/oci 885 Milner Avenue Scarborough, Ontario M1B 5V8 1-800-55-OMRON Cat. No. GC MSEN4 80 04/01 Specifications subject to change without notice. 416-286-6465 Printed in the U.S.A.