Document 134 50/60 Hz Current Sensor CS60-010 The CS60 series is designed to measure current from 5 to 100 Arms. Applications include sensing branch circuit overload and detecting load drop or shutdown. The sensor functions as the encapsulated secondary of a current transformer, while the conductor carrying the current to be measured serves as the "one turn primary." Sensitivity may be enhanced by increasing primary turns. These parts are mountable on printed circuits and have a third terminal added for mechanical stability. Samples of these and other current sensors are available for evaluation. To request samples, contact Coilcraft or visit www.coilcraft.com. Typical Response Part number Sensed current (Irms) Vout tolerance CS60-050L CS60-075L CS60-100L 5-50 A rms 5-75 A rms 5-100 A rms 10% 10% 10% (For sensed current below 10 A rms, see CS60-010 data sheet) 1. Ambient temperature range -40C to +85C. 2. Electrical specifications at 25C. VOUT (mVolts rms) Weight 13.8 - 15.4 g Terminations Tin-silver over copper Packaging 30 per tray 0.350 min 8,89 Parts manufactured prior to February, 2012 may be marked differently. CS60-0xxL 1.25 max 31,75 Part number Internal code XXXXY Current (A rms) Typical Circuit 0.600 0.010 15,24 0,254 0.040 0.002 dia 1,02 0,05 0.250 0.010 6,35 0,254 0.150 0.030 3,81 0,762 Irms 1 4 1 4 2 (N.C.) 220 2 (N.C.) Vout rms 1.10 max 27,94 US +1-847-639-6400 sales@coilcraft.com UK +44-1236-730595 sales@coilcraft-europe.com Taiwan +886-2-2264 3646 sales@coilcraft.com.tw China +86-21-6218 8074 sales@coilcraft.com.cn Singapore + 65-6484 8412 sales@coilcraft.com.sg 0.750 max 19,05 Dimensions are in Document 134 inches mm Revised 08/22/16 (c) Coilcraft Inc. 2016 This product may not be used in medical or high risk applications without prior Coilcraft approval. Specification subject to change without notice. Please check web site for latest information. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Coilcraft: CS60-100L CS60-050L CS60-075L