SPECIFICATION CONTROL DRAWING Page
2 of 2
Revision
B
SCD
400R0111
TABLE II. PERFORMANCE DETAILS
PART NUMBER
1/
BEND TESTING
MANDREL DIAMETER
(inch) (mm) (± 3%) WEIGHT
(lb) (kg) (± 3%)
ACCELERATED
AGING COLD
BEND ACCELERATED
AGING COLD
BEND
400R0111-26-* .500 (12.7) .500 (12.7) .250 (.113) .500 (.227)
400R0111-24-* .500 (12.7) .500 (12.7) .375 (.170) .500 (.227)
400R0111-22-* .750 (19.1) .750 (19.1) .375 (.170) 1.00 (.454)
400R0111-20-* .750 (19.1) .750 (19.1) .375 (.170) 1.00 (.454)
400R0111-18-* 1.00 (25.4) 1.00 (25.4) .500 (.227) 1.00 (.454)
400R0111-16-* 1.00 (25.4) 1.00 (25.4) .500 (.227) 1.00 (.454)
400R0111-14-* 1.50 (38.1) 1.50 (38.1) 1.00 (.454) 3.00 (1.36)
400R0111-12-* 2.00 (50.8) 2.00 (50.8) 1.00 (.454) 3.00 (1.36)
400R0111-10-* 2.50 (63.5) 2.50 (63.5) 1.00 (.454) 3.00 (1.36)
WIRE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 125°C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
ACCELERATED AGING: 300 ± 2°C for 6 hours
Identification legibility, 225 ± 2°C for 6 hours
BLOCKING: 150 ± 2°C for 24 hours
COLOR: White preferred
FLAMMABILITY: Char Length, 5 ft. (1.5 m) (maximum)
HUMIDITY RESISTANCE: Insulation Resistance,
5000 megohms for 1000 ft. (1524 megohms for 1 km) (minimum)
INSULATION ELONGATION AND TENSILE STRENGTH:
Primary Insulation,
Elongation, 150% (minimum)
Tensile Strength, 2500 lbf/in2 (17.2 MPa) (minimum)
INSULATION FLAWS:
Primary Insulation,
Spark Test, 1.5 kV (rms)
Impulse Dielectric Test, 6.0 kV (peak)
Finished Wire,
Spark Test, 3.0 kV (rms) at 3 kHz
Impulse Dielectric Test, 8.0 kV (peak)
INSULATION RESISTANCE:
5000 megohms for 1000 ft. (1524 megohms for 1 km) (minimum)
LOW TEMPERATURE-COLD BEND: -65 ± 2°C for 4 hours
SHRINKAGE: 300 ± 2°C, 0.125 in. (3.18 mm) (maximum) in 12 inches (305 mm)
SMOKE RELEASE:
Peak Smoke Release Rate, 0.40 m2/s (maximum)
Total Smoke Release, 150 m2 (maximum)
SMOKE TEST: D4, 50 (maximum); Dm, 300 (maximum)
TOXICITY: HCN: 100 ppm (maximum) SO2: 100 ppm (maximum)
CO: 3500 ppm (maximum) HF: 100 ppm (maximum)
NO: 100 ppm (maximum) HCI: 500 ppm (maximum)
VOLTAGE WITHSTAND (Post Environmental): 2500 volts (rms), 60 Hz, 5 minutes
1/ PART NUMBER:
The "*" in the part numbers in Tables I and II shall be replaced by a color code
designator.
Example: AWG 20, white: 400R0111-20-9
AWG 20, white with a black stripe: 400R0111-20-90
PRODUCT IDENTIFICATION:
Outer surface of wire shall be marked in contrasting color as follows:
"RAYCHEM 400R0111-xx - 600V Yr of Mfg" (xx = applicable AWG size)
1/ See footer section on page 1