The
LDD
family
of
DC/DC
converters
is
an
optimal
respons
e
to
the
applications
where compa
ctness and high
reliabilit
y are
requested.
All
are isolated and offer a wid
e range of input voltages
.
Simple
but
elegant
look
and
ease
of
ins
tallation
make
them
ideal
for
various industrial applications
.
High efficiency and compact size
Wide Input voltage range
Isolated topology
Overload 150%
Excellent reliability
Industrial machine control
Process control
Energy management
Remote control systems
2
LDD240 Series
tech.support@psbel.com
LDD
24
0-11024
110 VDC (90 -
148
V
DC
)
2.6 A
–
3.6 A
24 VDC
10
A
Technical
parameters
are
typical,
measured
in
laboratory
environment
at
25°C
at
110
V
DC
and
nominal
v
alues,
after
mini
mum
5 minutes of operation.
Input DC Voltage Range
Rated
Operating
110 VDC
90
- 148 VDC
Input
DC
Current
Vin = Min
Vin = Max
3.6 A
2.6 A
Input Overvoltage Protection
Active shutdown
> 150 V
DC
Inrush Peak Current
< 150 A
Internal Protection Fuse
Not user replaceable
Fuse AT 5 A
Recommended External Protection
Use DC rated devices
MCB 6 A C curve
Output Power
240 W
Rated Voltage (Adjustable Voltage Range)
24 VDC (23
–
27.5 VDC)
Continuous Current
10
A
Overload Limit
15
A
Short Circuit Peak Current
21
A
Load Regulation
≤
1.5%
Ripple & Noise
1
≤
50
mVpp
Hold up Time
≥
10
ms
Protections
Overload/short circuit: Hiccup mode
Thermal protection
Output overvoltage
Output Over Voltage Protection
≥
33
VDC
Status Signals
DC OK - green LED
OVERLOAD - red LED
DC OK - dry contact (NO, 24 VDC / 1 A)
Parallel Connection
Possible for power or redundancy (includes
internal ORing circuit)
Efficiency
> 88 %
Dissipated Power
< 31
W
1
Ripple and Noise are measured with 20 MHz bandwidth, probe terminated with a 0.1
μ
F MKP parallel capacitor.
NOTE:
Power rating, losses, efficiency, ripple, thermal behaviour and start-up may change outside of the nominal rated input range.
Contact factory for details.
LDD240 Series
3
Asia-Pacific
+86 755 298 85888
Europe
, Mi
ddle East
+353 61 225 977
North America
+1
408
785 5200
© 2016 Bel Power Solutions & Protection
BCD.00763_AA
Operating Temperature
Overtemperature protection
(Start-up type tested: -
40
°C)
2
- 40 to + 70°C
Storage Temperature
- 40 to + 80°C
Derating
- 3
W/
°C over 50
°C
Humidity
Non-condensing
5
- 95% RH
Life time expectation
At 25°C ambient
64000 h (7.3 years)
Overvoltage Category
Pollution Degree
I (EN50178)
2 (IEC60664-
1)
Protection Class
Class I
Isolation Voltage
Input to Output
Input to Ground
Output to Ground
2.1 kVDC
1.41 kVDC
0.75 kVDC
Safety Standards & Approvals
UL508 (reference)
EN60950 (reference)
EN50178 (reference)
EMC Standards
Emission
EN55022 (CISPR11)
EN55011 (CISPR22)
Class A
Class A
Immunity
EN61000-4-2
EN61000-4-
3
EN61000-4-4
EN61000-4-5
EN61000-4-
11
Level 3
Level 3
Level 2
Level 2
Level 2
Protection Degree
EN60529
IP20
Vibration sinusoidal
IEC 60068-2-6
5-17.8 Hz: ±1.6 mm; 17.8-500 Hz:
2 g 2Hours / axis (X,Y,Z)
Shock
IEC 60068-2-
27
30
g 6
ms, 20 g 11 ms; 3 bumps / direction,
18 bumps total
2
Possible at nominal voltage with load deration.
Weight
800 g
Dimensions
69
x 115 x 110
mm
Mounting Rail
IEC 60715/H15/TH35-7.5(-
15)
Connection Terminals
Screw type pluggable (24 - 12 AWG)
2.5 mm²
Case Material
Aluminum
4
LDD240 Series
tech.support@psbel.com
Figure 1. Mechanical Drawing
1
DC input
2
DC output (Load)
3
Output voltage adjustment
4
Green LED: Output OK
5
Red LED: Overload
6
Diagnostic Output
(dry contacts, NC out OK)
INPUT CONNECTION
OUTPUT CONNECTION
+ = Positive DC
-
= Negative DC
= Earth ground
+ = Positive DC
-
= Negative DC
Signaling:
DC OK (dry contact)
NO
COM
NUCLEAR AND MEDICAL APPLICATIONS
- Products are not designed or intended for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS
- The appearance of products, including safety agency certifications pictured on labels, may change dependin
g on the
date manufactured. Specifications are subject to change without notice.