E3M-V E3M-V
Precautions
JSAFETY
Observe the following precautions to ensure safety.
•Do not use the Sensor in locations subject to flammable or
explosive gases.
•Do not use the Sensor in water or conductive solution.
•Do not disassemble, repair, or modify the Sensor.
•Use the Sensor under proper power supply specifications
such as the use of AC or DC power supply.
•Do not apply any voltage or current exceeding the rated level.
•Be careful with the power supply polarities and wire correctly.
•Connect the loads correctly.
•Do not short-circuit both ends of loads.
JINSTALLATION AND USE
Power Reset Time
Since the E3M-V is ready to detect objects from 100 ms max.
after the E3M-V is turned ON, operate the remaining devices
100 ms after the Sensor is turned ON. If power is supplied to the
E3M-V and the load independently, be sure to turn on the E3M-V
first.
Power OFF
The E3M-V may output a single pulse when the control power
supply is turned OFF. If the E3M-V is connected to a timer or
counter to which power is supplied from an independent power
supply, the E3M-V will be more likely to output a single pulse
when the control power supply is turned OFF. For this reason,
supply power to the timer or counter from the same power supply
for the E3M-V.
Power Supply Type
Supply voltage ripple must not exceed rated percentage.
Power Supply Connection
Be sure to ground the FG (frame ground) and G (ground)
terminals if a switching regulator is connected to the E3M-V to
avoid malfunction due to the switching noise of the switching
regulator.
JWIRING
Cable
•The cable can be extended up to 100 m provided that the
thickness of the cable is 0.3 mm2minimum.
•The cable must not be bent repeatedly.
•Do not pull cables with pulling forces exceeding 50N
(11.24 lb).
High-tension Lines
To avoid damage and malfunctioning due to induction noise, wire
sensor power lines in a separate conduit from any power lines or
high tension lines.
JMOUNTING
Screw Tightening
Make sure that the casing is tightened to a maximum torque of
1.2 N Sm.
Mounting Direction
When Sensors are mounted to face each other, make sure to
adjust the optical axes to avoid mutual interference.
JEEPROM WRITE ERROR
An EEPROM error may result if power supply to the Sensor fails
or the Sensor is influenced by static noise, and the threshold
level indicators will flash. Perform the teaching and threshold
level setting of the E3M-V again.
JM12 METAL CONNECTOR
•Turn off the E3M-V before connecting or disconnecting the
metal connector.
•Make sure to hold the connector cover when connecting or
disconnecting the metal connector.
•Tighten the metal connector securely by hand. To avoid dam-
age, do not use any tool, such as pliers.
•If the metal connector is not tightened securely, it may be
disconnected by vibration, and the proper degree of protec-
tion of the E3M-V may not be maintained.
Cat. No. CEDSAX4 11/01 Specifications subject to change without notice. Printed in U.S.A.
OMRONELECTRONICSLLC
One EastCommerceDrive
Schaumburg, IL 60173
NOTE:DIMENSIONS SHOWN AREINMILLIMETERS.To convertmillimeterstoinches divideby 25.4.
1-800-55-OMRON
OMRON CANADA, INC.
885 MilnerAvenue
Scarborough,OntarioM1B5V8
416-286-6465
R
OMRONON--LINE
Global-- http://www.omron.com
USA -- http://www.omron.com/oei
Canada -- http://www.omron.com/oci