AIM & THURLBY THANDAR INSTRUMENTS
TGR1040 & 2050
1GHz and 2GHz synthesised RF signal generators
high stability and low phase noise
TGR2050 - FREQUENCY
Frequency Range: 150kHz to 2000MHz
Setting Resolution: 10Hz by direct keyboard entry, or in user-set incre-
ments of 10Hz to 999·99999MHz.
Display Resolution: 10Hz.
Frequency Accuracy: See Frequency Reference specifications.
Phase Noise: -116dBc/Hz at 25kHz offset, 500MHz carrier.
Residual FM:
(FM Off)
Equivalent peak deviation in a 300Hz to 3·4kHz band-
width: 12Hz at 500MHz carrier.
TGR2050 - REFERENCE FREQUENCY
Options: Internal or External (via rear panel BNC).
Internal Accuracy: < ± 1 ppm over temperature range 15°C to 30°C
(< ± 2 ppm over temperature range 5°C to 40°C).
Internal Stability: < ± 1 ppm per year.
Internal Ref. Out: 10MHz from 50W, amplitude 2V pk-pk into 50W.
External Ref In: 10MHz into 50W, amplitude 2V pk-pk to 5V pk-pk.
TGR2050 - OUTPUT LEVEL
Output Level Range: –127dBm to +7dBm (0·1µV to 500mV into 50W),
–127dBm to +1dBm in AM mode.
Setting Resolution: 0·1dB (or 0·01µV to 1mV) by direct keyboard entry, or
in user-set increments of 0·1dB to 100dB (or 0·01µV
to 100mV).
Accuracy: Better than ± 2dBm.
Harmonics: <-25dBc @ +7dBm.
Sub-Harmonics: < 1000MHz - None; > 1000MHz - <-25dBc at +7dBm.
Non-Harmonic Spurii: <–60dBc at >62.5MHz, <–50dBc at <62.5MHz,
Carrier Leakage: <0.5uV generated into a 50Wload by a 2 turn 25mm
loop, at a distance of 25mm from the generator with
the output set to <-10dBm into a 50Wsealed load.
Output Type: Output impedance 50W, Type N connector.
Reverse Protection: 50V DC, up to 25W from 50Wsource, LED indication.
Output Switch: RF OUT on-off switch with LED showing ON status.
TGR2050 - MODULATION
Modulation Source
Type: Internal from built-in sine wave generator, or external
from front panel BNC.
Internal: 400Hz or 1kHz sine, signal also available as an out-
put.
External: Calibrated for 1V rms sine, input impedance 600W.
Frequency Modulation
Max Peak Deviation: See Table.
Setting Resolution: 0.5 kHz.
Deviation Accuracy: <±10% ±0.5kHz for 1kHz Internal
or 1kHz / 1Vrms External Modulation.
External Modulation: 100Hz - 300kHz (±2dB relative to 1kHz).
Distortion: < 2% @ 1kHz modulation, max. deviation
(300-3.4kHz bandwidth).
Phase Modulation
Max Peak Deviation: See Table.
Setting Resolution: 0.05 rads for <10.0rads deviation,
0.1 rads for >10.0rads deviation.
Deviation Accuracy: <±10% ±0.05rads for 1kHz Internal
or 1kHz / 1Vrms External Modulation.
External Modulation: 100Hz - 10kHz (±2dB relative to 1kHz).
Distortion: < 2% @ 1kHz modulation, max. deviation
(300-3.4kHz bandwidth).
Max. Peak Deviation versus Carrier Frequency
Frequency Mod. Phase Modulation
1000MHz - 2000MHz 800kHz 80.0 rads
500MHz - 1000MHz 400kHz 40.0 rads
250MHz - 500MHz 200kHz 20.0 rads
125MHz - 250MHz 100kHz 10.0 rads
62.5MHz - 125MHz 50kHz 5.0 rads
150kHz - 62.5MHz 100kHz 10.0 rads
Amplitude Modulation
Max Mod. Depth: 100%, useability decreasing to 90% at 2GHz.
Setting Resolution: 0.5%.
Deviation Accuracy: <±(5% setting +1%) for 1kHz Internal
or 1kHz / 1Vrms External Modulation, <70% depth.
External Modulation: 50Hz - 200kHz (±1dB relative to 1kHz).
Distortion: 150kHz to 1GHz - <3% @ 30%, <5% @ 70%
1GHz to 2GHz - <5% @ 30%, <10% @ 70%
@ 1kHz modulation, max. deviation (300-3.4kHz
bandwidth).
TGR1040/2050 - BUS INTERFACES
Full remote control facilities are available through both RS232 and GPIB in-
terfaces (RS232 included on both units, GPIB included on TGR2050 and
optional on TGR1040).
RS232: Variable Baud rate, 19200 Baud maximum, 9-pin
D-connector. Fully compatible with TTi ARC (Address-
able RS232 Chain) system.
GPIB (IEEE-488): Conforming with IEEE488·1 and IEEE488·2.
TGR1040/2050 - GENERAL SPECIFICATIONS
General
Display: 20 character x 4 row backlit alphanumeric LCD
Data Entry: Keyboard selection of frequency, amplitude, etc.;
value entry direct by numeric keys or by rotary control.
Stored Settings: Up to 9 complete instrument set-ups may be stored
and recalled from battery-backed memory.
Mechanical
Size: 130mm (3U) H; 212mm (half-rack) W; 330mm D.
Weight: 4·6 kg. (10 lb)
Power Requirements
100V or 110V - 120V or 220V - 240V, all ±10% 50/60Hz,
adjustable internally; 30VA max. Installation Category II.
Temperature & Environmental
Operating Range: +5°C to 40°C, 20-80% RH.
Storage Range: –20°C to + 60°C.
Environmental: Indoor use at altitudes up to 2000m,
Pollution Degree 2.
Safety & EMC
Safety: Complies with EN61010-1.
EMC: Complies with EN61326.
MODEL RANGE
Models Available: TGR1040 (includes RS-232 interface).
TGR1040GP (includes RS-232 and GPIB interfaces).
TGR2050 (includes RS-232 and GPIB interfaces).
Options: 19 inch rack mounting kit.
Specifications apply after 30 minute warm-up, ambient 5°C to 40°C
wide amplitude range and low leakage
flexible signal modulation capabilities
82100-0092 Iss. 2A
TGR Series low-cost synthesised RF generators TGR2050 - 150kHz to 2000MHz
TGR1040 - 10MHz to 1000MHz
Overview
The TGR series are low cost, synthesised RF signal genera-
tors that incorporate the essential features required for most
development, test and service work; namely high frequency
accuracy and stability, wide dynamic range, low phase noise
and leakage, and flexible modulation capabilities.
The TGR2050 covers from 150kHz up to 2GHz and incorporates
AM, FM and Phase modulation (internal and external).
The wide frequency range and comprehensive modulation ca-
pabilities make it suitable for most tasks within the 2GHz spec-
trum.
The TGR1040 has a more restricted frequency range of 10MHz
to 1GHz and incorporates FM modulation only (internal and ex-
ternal). It retains the high stability and wide amplitude range of
the 2050 making it suitable for many task including FM radio re-
ceiver sensitivity measurements, system gain measurements,
receiver tuning & alignment, oscillator substitutions, EMC/an-
tenna/field strength measurements and as a signal source for
many other RF circuit and system development tasks.
Both instruments can be operated using either numeric or rotary
controls, and can be remotely controlled via either an RS-232 in-
terface or GPIB interface. Nine memories are provided for user
set-ups.
Lower cost through innovative design
The TGR series sets a new price standard for high performance
RF generators. Advanced design techniques utilising the latest
component technologies have made this possible.
The low cost makes it possible for every engineer involved in RF
design, manufacture or testing to have a generator of their own.
High Precision and Stability
The TGR series uses a fully synthesised source locked to a tem-
perature compensated crystal oscillator. This provides excellent
signal frequency stability against temperature and ageing. The
TGR2050 adds the further capability of locking to an external
10MHz source.
The frequency can be set to a resolution of 10Hz across the
whole frequency range (1kHz resolution on TGR1040).
Frequency steps can be set to any value and stepping can be
done with up/down keys or the rotary encoder.
The frequency stepping system makes operations such as pre-
cise amplitude response characterisation particularly easy.
Wide Amplitude Range & Low Leakage
The TGR series provides an amplitude range of –127dBm to
+7dBm (0·1µV to 500mV into 50W). Setting resolution is 0.1dBm
or 0.01µV.
Output level steps can be set anywhere between 0·1dBm and
100dBm (or 0·01µV to 100mV depending on the entry mode).
Stepping the level is useful for quick assessment of circuit linear-
ity and dynamic range for instance.
The advanced attenuator design provide excellent flatness over
the whole frequency range.
Meticulous internal screening provides very low output leakage
enabling accurate low level measurements in sensitive circuits
such as receivers.
Ease of use
The TGR series incorporates a simple and straightforward user
interface.
The back-lit four line display shows all the major signal parame-
ters simultaneously. Data can be entered numerically using0-9
keys or can be incremented/decremented using up/down keys or
the rotary encoder. Both frequency and output level can be ad-
justed in steps of user programmed size.
Output level can be set either in dBm or linear units of µV or mV.
A single button press will translate from one to the other.
The TGR series can store nine full instrument set-ups in
non-volatile memory. This allows repetitive testing procedures
to be undertaken quickly and accurately.
Full remote control
The TGR series provides full remote control facilities for all its
functions using both RS-232 and GPIB (IEEE-488.2) interfaces.
(GPIB is an option for the TGR1040).
Technical Specifications
TGR1040 - FREQUENCY
Frequency Range: 10MHz to 1000MHz
Setting Resolution: 1kHz by direct keyboard entry, or in user-set incre-
ments of 1kHz to 999·999MHz.
Display Resolution: 1kHz
Accuracy: < ± 1 ppm over temperature range 15°C to 30°C
< ± 2 ppm over temperature range 5°C to 40°C.
Stability: < ± 1ppm/year ageing.
Phase Noise: -110dBc/Hz at 25kHz offset, 500MHz carrier.
Residual FM:
(FM Off)
Equivalent peak deviation in a 300Hz to 3·4kHz
bandwidth: 17Hz at 500MHz carrier.
TGR1040 - OUTPUT LEVEL
Output Level Range: –127dBm to +7dBm (0·1µV to 500mV into 50W).
Setting Resolution: 0·1dB (or 0·01µV to 1mV) by direct keyboard entry,
or in user-set increments of 0·1dB to 100dB (or
0·01µV to 100mV).
Accuracy: Better than ± 2dBm, except for output levels
<-70dBm at 500 -1000 MHz, ± 3dBm.
Harmonics: Typically <-25dBc, maximum –20dBc, any carrier fre-
quency, output level <0dBm.
Non-Harmonic Spurii: <–60dBc at >8kHz offset.
Carrier Leakage: <0.5uV generated into a 50Wload by a 2 turn 25mm
loop, at a distance of 25mm from the generator with
the output set to <-10dBm into a 50Wsealed load.
Output Type: Output impedance 50W, Type N connector, Reverse
protection 50V DC.
Output Switch: RF OUT on-off switch with LED showing ON status.
TGR1040 - FM MODULATION
Peak Deviation: 0·5kHz to 100kHz.
Setting Resolultion: 0·5kHz .
Modulation Frequency: Internal 1kHz; External 300Hz to 50kHz
Deviation Accuracy: <±10% of setting ±0.5kHz, excluding residual FM,
for 1kHz modulation, internal or 1Vrms external.
External Modulation
Frequency Response: ± 1dB from 300Hz to 50kHz relative to 1kHz.
Distortion: <2% total harmonic distortion at 1kHz modulating fre-
quency, 100kHz deviation and 500MHz carrier.
Input Type: BNC connector, input impedance 100kW
TGR1040 - FURTHER SPECIFICATIONS
Specifications for Bus Interfaces, Power Requirement, Mechanical Details
etc. are given on the rear page.
Comprehensive Modulation
The TGR2050 offers AM, FM and Phase modulation using either
an internal or external source.
Wide modulation range and low distortion make the TGR2050
suitable for most modulated signal test procedures.
The TGR1040 provides FM modulation only using either an in-
ternally generated modulator signal or an external signal in the
range 300Hz to 50kHz.
This wide bandwidth allows for audio band demodulator testing
as well as LF digital modulation.
TGR Series
u
Setability of 10Hz at up to 2GHz (TGR2050)
u
Accuracy better than 1 ppm over 15oC to 30oC
u
Ageing better than 1 ppm over one year
u
External frequency locking (TGR2050)
u
Low phase noise and low leakage
u
Amplitude range of -127dBm to +7dBm
u
Amplitude entry in dBm or µV / mV
u
Amplitude setability of 0.1dBm or 0.01µV
u
FM, Phase and AM modulation (TGR2050)
u
Direct numeric entry or rotary control with user
setable frequency/amplitude increments
u
Non-volatile storage for 9 generator set-ups
u
Full remote control via RS-232 or GPIB
u
Unmatched price/performance ratio
TGR Series low-cost synthesised RF generators TGR2050 - 150kHz to 2000MHz
TGR1040 - 10MHz to 1000MHz
Overview
The TGR series are low cost, synthesised RF signal genera-
tors that incorporate the essential features required for most
development, test and service work; namely high frequency
accuracy and stability, wide dynamic range, low phase noise
and leakage, and flexible modulation capabilities.
The TGR2050 covers from 150kHz up to 2GHz and incorporates
AM, FM and Phase modulation (internal and external).
The wide frequency range and comprehensive modulation ca-
pabilities make it suitable for most tasks within the 2GHz spec-
trum.
The TGR1040 has a more restricted frequency range of 10MHz
to 1GHz and incorporates FM modulation only (internal and ex-
ternal). It retains the high stability and wide amplitude range of
the 2050 making it suitable for many task including FM radio re-
ceiver sensitivity measurements, system gain measurements,
receiver tuning & alignment, oscillator substitutions, EMC/an-
tenna/field strength measurements and as a signal source for
many other RF circuit and system development tasks.
Both instruments can be operated using either numeric or rotary
controls, and can be remotely controlled via either an RS-232 in-
terface or GPIB interface. Nine memories are provided for user
set-ups.
Lower cost through innovative design
The TGR series sets a new price standard for high performance
RF generators. Advanced design techniques utilising the latest
component technologies have made this possible.
The low cost makes it possible for every engineer involved in RF
design, manufacture or testing to have a generator of their own.
High Precision and Stability
The TGR series uses a fully synthesised source locked to a tem-
perature compensated crystal oscillator. This provides excellent
signal frequency stability against temperature and ageing. The
TGR2050 adds the further capability of locking to an external
10MHz source.
The frequency can be set to a resolution of 10Hz across the
whole frequency range (1kHz resolution on TGR1040).
Frequency steps can be set to any value and stepping can be
done with up/down keys or the rotary encoder.
The frequency stepping system makes operations such as pre-
cise amplitude response characterisation particularly easy.
Wide Amplitude Range & Low Leakage
The TGR series provides an amplitude range of –127dBm to
+7dBm (0·1µV to 500mV into 50W). Setting resolution is 0.1dBm
or 0.01µV.
Output level steps can be set anywhere between 0·1dBm and
100dBm (or 0·01µV to 100mV depending on the entry mode).
Stepping the level is useful for quick assessment of circuit linear-
ity and dynamic range for instance.
The advanced attenuator design provide excellent flatness over
the whole frequency range.
Meticulous internal screening provides very low output leakage
enabling accurate low level measurements in sensitive circuits
such as receivers.
Ease of use
The TGR series incorporates a simple and straightforward user
interface.
The back-lit four line display shows all the major signal parame-
ters simultaneously. Data can be entered numerically using0-9
keys or can be incremented/decremented using up/down keys or
the rotary encoder. Both frequency and output level can be ad-
justed in steps of user programmed size.
Output level can be set either in dBm or linear units of µV or mV.
A single button press will translate from one to the other.
The TGR series can store nine full instrument set-ups in
non-volatile memory. This allows repetitive testing procedures
to be undertaken quickly and accurately.
Full remote control
The TGR series provides full remote control facilities for all its
functions using both RS-232 and GPIB (IEEE-488.2) interfaces.
(GPIB is an option for the TGR1040).
Technical Specifications
TGR1040 - FREQUENCY
Frequency Range: 10MHz to 1000MHz
Setting Resolution: 1kHz by direct keyboard entry, or in user-set incre-
ments of 1kHz to 999·999MHz.
Display Resolution: 1kHz
Accuracy: < ± 1 ppm over temperature range 15°C to 30°C
< ± 2 ppm over temperature range 5°C to 40°C.
Stability: < ± 1ppm/year ageing.
Phase Noise: -110dBc/Hz at 25kHz offset, 500MHz carrier.
Residual FM:
(FM Off)
Equivalent peak deviation in a 300Hz to 3·4kHz
bandwidth: 17Hz at 500MHz carrier.
TGR1040 - OUTPUT LEVEL
Output Level Range: –127dBm to +7dBm (0·1µV to 500mV into 50W).
Setting Resolution: 0·1dB (or 0·01µV to 1mV) by direct keyboard entry,
or in user-set increments of 0·1dB to 100dB (or
0·01µV to 100mV).
Accuracy: Better than ± 2dBm, except for output levels
<-70dBm at 500 -1000 MHz, ± 3dBm.
Harmonics: Typically <-25dBc, maximum –20dBc, any carrier fre-
quency, output level <0dBm.
Non-Harmonic Spurii: <–60dBc at >8kHz offset.
Carrier Leakage: <0.5uV generated into a 50Wload by a 2 turn 25mm
loop, at a distance of 25mm from the generator with
the output set to <-10dBm into a 50Wsealed load.
Output Type: Output impedance 50W, Type N connector, Reverse
protection 50V DC.
Output Switch: RF OUT on-off switch with LED showing ON status.
TGR1040 - FM MODULATION
Peak Deviation: 0·5kHz to 100kHz.
Setting Resolultion: 0·5kHz .
Modulation Frequency: Internal 1kHz; External 300Hz to 50kHz
Deviation Accuracy: <±10% of setting ±0.5kHz, excluding residual FM,
for 1kHz modulation, internal or 1Vrms external.
External Modulation
Frequency Response: ± 1dB from 300Hz to 50kHz relative to 1kHz.
Distortion: <2% total harmonic distortion at 1kHz modulating fre-
quency, 100kHz deviation and 500MHz carrier.
Input Type: BNC connector, input impedance 100kW
TGR1040 - FURTHER SPECIFICATIONS
Specifications for Bus Interfaces, Power Requirement, Mechanical Details
etc. are given on the rear page.
Comprehensive Modulation
The TGR2050 offers AM, FM and Phase modulation using either
an internal or external source.
Wide modulation range and low distortion make the TGR2050
suitable for most modulated signal test procedures.
The TGR1040 provides FM modulation only using either an in-
ternally generated modulator signal or an external signal in the
range 300Hz to 50kHz.
This wide bandwidth allows for audio band demodulator testing
as well as LF digital modulation.
TGR Series
u
Setability of 10Hz at up to 2GHz (TGR2050)
u
Accuracy better than 1 ppm over 15oC to 30oC
u
Ageing better than 1 ppm over one year
u
External frequency locking (TGR2050)
u
Low phase noise and low leakage
u
Amplitude range of -127dBm to +7dBm
u
Amplitude entry in dBm or µV / mV
u
Amplitude setability of 0.1dBm or 0.01µV
u
FM, Phase and AM modulation (TGR2050)
u
Direct numeric entry or rotary control with user
setable frequency/amplitude increments
u
Non-volatile storage for 9 generator set-ups
u
Full remote control via RS-232 or GPIB
u
Unmatched price/performance ratio
Technical Specifications (continued)
Designed and built in Europe by:
Thurlby Thandar Instruments Ltd. operates a policy of continuous development and
reserves the right to alter specifications without prior notice.
Thurlby Thandar Instruments Ltd.
Glebe Road, Huntingdon. Cambs. PE29 7DR United Kingdom (UK)
Tel: +44 (0)1480 412451 Fax: +44 (0)1480 450409
Email: info@aimtti.com Web: www.aimtti.com
AIM & THURLBY THANDAR INSTRUMENTS
TGR1040 & 2050
1GHz and 2GHz synthesised RF signal generators
high stability and low phase noise
TGR2050 - FREQUENCY
Frequency Range: 150kHz to 2000MHz
Setting Resolution: 10Hz by direct keyboard entry, or in user-set incre-
ments of 10Hz to 999·99999MHz.
Display Resolution: 10Hz.
Frequency Accuracy: See Frequency Reference specifications.
Phase Noise: -116dBc/Hz at 25kHz offset, 500MHz carrier.
Residual FM:
(FM Off)
Equivalent peak deviation in a 300Hz to 3·4kHz band-
width: 12Hz at 500MHz carrier.
TGR2050 - REFERENCE FREQUENCY
Options: Internal or External (via rear panel BNC).
Internal Accuracy: < ± 1 ppm over temperature range 15°C to 30°C
(< ± 2 ppm over temperature range 5°C to 40°C).
Internal Stability: < ± 1 ppm per year.
Internal Ref. Out: 10MHz from 50W, amplitude 2V pk-pk into 50W.
External Ref In: 10MHz into 50W, amplitude 2V pk-pk to 5V pk-pk.
TGR2050 - OUTPUT LEVEL
Output Level Range: –127dBm to +7dBm (0·1µV to 500mV into 50W),
–127dBm to +1dBm in AM mode.
Setting Resolution: 0·1dB (or 0·01µV to 1mV) by direct keyboard entry, or
in user-set increments of 0·1dB to 100dB (or 0·01µV
to 100mV).
Accuracy: Better than ± 2dBm.
Harmonics: <-25dBc @ +7dBm.
Sub-Harmonics: < 1000MHz - None; > 1000MHz - <-25dBc at +7dBm.
Non-Harmonic Spurii: <–60dBc at >62.5MHz, <–50dBc at <62.5MHz,
Carrier Leakage: <0.5uV generated into a 50Wload by a 2 turn 25mm
loop, at a distance of 25mm from the generator with
the output set to <-10dBm into a 50Wsealed load.
Output Type: Output impedance 50W, Type N connector.
Reverse Protection: 50V DC, up to 25W from 50Wsource, LED indication.
Output Switch: RF OUT on-off switch with LED showing ON status.
TGR2050 - MODULATION
Modulation Source
Type: Internal from built-in sine wave generator, or external
from front panel BNC.
Internal: 400Hz or 1kHz sine, signal also available as an out-
put.
External: Calibrated for 1V rms sine, input impedance 600W.
Frequency Modulation
Max Peak Deviation: See Table.
Setting Resolution: 0.5 kHz.
Deviation Accuracy: <±10% ±0.5kHz for 1kHz Internal
or 1kHz / 1Vrms External Modulation.
External Modulation: 100Hz - 300kHz (±2dB relative to 1kHz).
Distortion: < 2% @ 1kHz modulation, max. deviation
(300-3.4kHz bandwidth).
Phase Modulation
Max Peak Deviation: See Table.
Setting Resolution: 0.05 rads for <10.0rads deviation,
0.1 rads for >10.0rads deviation.
Deviation Accuracy: <±10% ±0.05rads for 1kHz Internal
or 1kHz / 1Vrms External Modulation.
External Modulation: 100Hz - 10kHz (±2dB relative to 1kHz).
Distortion: < 2% @ 1kHz modulation, max. deviation
(300-3.4kHz bandwidth).
Max. Peak Deviation versus Carrier Frequency
Frequency Mod. Phase Modulation
1000MHz - 2000MHz 800kHz 80.0 rads
500MHz - 1000MHz 400kHz 40.0 rads
250MHz - 500MHz 200kHz 20.0 rads
125MHz - 250MHz 100kHz 10.0 rads
62.5MHz - 125MHz 50kHz 5.0 rads
150kHz - 62.5MHz 100kHz 10.0 rads
Amplitude Modulation
Max Mod. Depth: 100%, useability decreasing to 90% at 2GHz.
Setting Resolution: 0.5%.
Deviation Accuracy: <±(5% setting +1%) for 1kHz Internal
or 1kHz / 1Vrms External Modulation, <70% depth.
External Modulation: 50Hz - 200kHz (±1dB relative to 1kHz).
Distortion: 150kHz to 1GHz - <3% @ 30%, <5% @ 70%
1GHz to 2GHz - <5% @ 30%, <10% @ 70%
@ 1kHz modulation, max. deviation (300-3.4kHz
bandwidth).
TGR1040/2050 - BUS INTERFACES
Full remote control facilities are available through both RS232 and GPIB in-
terfaces (RS232 included on both units, GPIB included on TGR2050 and
optional on TGR1040).
RS232: Variable Baud rate, 19200 Baud maximum, 9-pin
D-connector. Fully compatible with TTi ARC (Address-
able RS232 Chain) system.
GPIB (IEEE-488): Conforming with IEEE488·1 and IEEE488·2.
TGR1040/2050 - GENERAL SPECIFICATIONS
General
Display: 20 character x 4 row backlit alphanumeric LCD
Data Entry: Keyboard selection of frequency, amplitude, etc.;
value entry direct by numeric keys or by rotary control.
Stored Settings: Up to 9 complete instrument set-ups may be stored
and recalled from battery-backed memory.
Mechanical
Size: 130mm (3U) H; 212mm (half-rack) W; 330mm D.
Weight: 4·6 kg. (10 lb)
Power Requirements
100V or 110V - 120V or 220V - 240V, all ±10% 50/60Hz,
adjustable internally; 30VA max. Installation Category II.
Temperature & Environmental
Operating Range: +5°C to 40°C, 20-80% RH.
Storage Range: –20°C to + 60°C.
Environmental: Indoor use at altitudes up to 2000m,
Pollution Degree 2.
Safety & EMC
Safety: Complies with EN61010-1.
EMC: Complies with EN61326.
MODEL RANGE
Models Available: TGR1040 (includes RS-232 interface).
TGR1040GP (includes RS-232 and GPIB interfaces).
TGR2050 (includes RS-232 and GPIB interfaces).
Options: 19 inch rack mounting kit.
Specifications apply after 30 minute warm-up, ambient 5°C to 40°C
wide amplitude range and low leakage
flexible signal modulation capabilities
82100-0092 Iss. 2A
Thurlby Thandar Instruments Ltd.
Glebe Road, Huntingdon, Cambridgeshire PE29 7DR England (United Kingdom)
Tel: +44 (0)1480 412451 Fax: +44 (0)1480 450409
Email: info@aimtti.com Web: www.aimtti.com
Designed and built in Europe by:
Company name and product brands
Thurlby Thandar Instruments Ltd. (TTi) is one of Europe’s leading
manufacturers of test and measurement instruments.
Products have been sold under two brand names:
TTi and Aim.
In the future, however, the full product range will be branded Aim-TTi.
This changeover will be gradual and many products will continue to carry
the TTi or Aim brands for some time to come.
Web Addresses (URLs)
The preferred URL for obtaining information concerning Aim-TTi products
is:
www.aimtti.com (international customers)
Customers in the UK should use the URL:
www.aimtti.co.uk
Customers in the USA should use the URL:
www.aimtti.us
Note that previous URLs such as www.tti-test.com will continue to operate
for the time being.
Product Summary
Laboratory Power Supplies
Bench and system power supplies from 30 watts up to
1200 watts using linear, mixed-mode and PowerFlex
regulation technologies.
Waveform Generators
Analog and digital (DDS) function generators, true
arbitrary generators, arbitrary/function generators and
pulse generators.
Precision Measurement Instruments
Benchtop DMMs, frequency counters, component
measurement instruments (LCR), electronic dc loads,
current probes.
RF and EMC Test Equipment
Spectrum analyzers, signal generators, frequency counters,
power meters, emc measurement instruments.