SPECIFICATION
ORDERNO.
SAFETY MODEL NO.
DCVOLTAGE Note.2
RATEDCURRENT
CURRENTRANGE
RATEDPOWER (max.)
RIPPLE&NOISE(max.) Note.3
OUTPUT
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
ACCURRENT
INPUT
ENVIRONMENT
INRUSHCURRENT(max.)
LEAKAGECURRENT(max.)
SAFETY STANDARDS
SAFETY &
EMC
(Note.6)
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
5V
GS40A05
GS40A05-P1J GS40A07-P1J GS40A09-P1J GS40A12-P1J GS40A15-P1J GS40A18-P1J GS40A24-P1J GS40A48-P1J
7.5V
GS40A07
9V
GS40A09
12V
GS40A12
15V
GS40A15
18V
GS40A18
24V
GS40A24
48V
GS40A48
100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 180mVp-p 240mVp-p
VOLTAGETOLERANCE Note.4
LINEREGULATION Note.5
LOADREGULATION
5.0% 5.0% 5.0% 3.0% 3.0% 3.0% 2.5% 2.5%
1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0%
5.0% 5.0% 5.0% 3.0% 3.0% 3.0% 2.5% 2.5%
90~264VAC135~370VDC
47~63Hz
81% 85.5%
7.88~10.13V
85%
9.45~12.15V
89%
12.6~16.2V
89.5%
15.75~20.25V
90%
18.9~24.8V
91%
25.2~32.4V
92.5%
50.4~64.8V
1A /115VAC0.5A /230VAC
60A /230VAC
0.75mA /240VAC
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
711Khrsmin.MIL-HDBK-217F(25 )
0~+50 (Refertooutputloadderatingcurve)
20%~90%RHnon-condensing
-20~+85 ,10~95%RH
0.03%/ (0~50 )
10~500Hz,2G10min./1cycle,periodfor60min. eachalongX, Y,Zaxes
125*50*31.5mm(L*W*H)
0.31Kg;50pcs/16.5Kg/1.13CUFT
CONNECTOR
PLUG
CABLE
Standardtype forstock thertypeavailablebycustomerrequestedP1J:2.1 *5.5 *11mm,tuningforktype,centerpositive ;O
Seepage2 thertypeavailablebycustomerrequested;O
1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
7. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
40WAC-DCSingleOutputDesktop GS40 series
Features :
CompliancetoEN61000-3-2,3,GB17625.1
CompliancetoEN61000-4-2,3,4,5,6,8,11,lightindustrylevel,criteria A
HARMONICCURRENT
EMSIMMUNITY
EMICONDUCTION&RADIATION
OVERLOAD
OVERVOLTAGE
105~140% ratedoutputpower
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
5.25~6.75V
5A 5.34A 4.45A 3.34A 2.67A 2.22A 1.67A 0.84A
0~5A 0~5.34A 0~4.45A 0~2.67A 0~2.22A 0~1.67A
0~0.84A
25W 40W 40W 40W
0~3.34A
40W 40W 40W 40W
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
UL60950-1, TUVEN60950-1,BSMICNS14336,CCCGB4943approved
CompliancetoEN55022classB,FCCPART 15/CISPR22classB,CNS13438classB,GB9254classB
Universal AC input / Full range
No load power consumption<0.3W
Energy star(CEC) level compliant
Energy star(CEC) draft V2.0 level (12V~48V)
3 pole AC inlet IEC320-C14
Class power ( with earth pin)
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
LED indicator for power on
Approvals: UL / CUL / TUV / BSMI / CCC / CB / FCC / CE
2 years warranty
600ms,30ms/230VAC600ms,30ms/115VACatfullload
50ms/230VAC15ms/115VACatfullload
TUV
Rheinland
Pro duc tSafe ty
geprUfre
Sicherheit
SETUP,RISETIME Note.7
HOLDUP TIME (Typ.)
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG /25 /70%RH
:100MOhms/500VDC
MeanWell Direct