PRELIMINARY First Edition Nov 12, 2001 Final Revision ****** LCD Module Technical Specification O PTREX T-51638D084-FW-A-AA Checked by (Quality Assurance Div.) Checked by (Design Engineering Div.) Prepared by (Production Div.) Table of Contents 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Overview .................................................................................................................................................. 2 Absolute Maximum Ratings ........................................................................................................ 3 Electrical Characteristics .............................................................................................................. 3 Interface Pin Connection .............................................................................................................. 5 Interface Timing ................................................................................................................................. 6 Block Diagram ....................................................................................................................................... 9 Mechanical Specification............................................................................................................... 10 Optical Characteristics ................................................................................................................ 12 Reliability Test Condition.......................................................................................................... 14 Handling Precautions for TFT-LCD Module ................................................................. 15 Revision History Rev. Date T-51638D084-FW-A-AA Page Comment OPTREX CORPORATION Page 1/17 PRELIMINARY 1. OVERVIEW T-51638D084-FW-A-AA is 8.4" color TFT-LCD (Thin Film Transistor Liquid Crystal Display) module composed of LCD panel, driver ICs, control circuit, and backlight unit. By applying 6 bit digital data, 640 480, 262,144-color images are displayed on the 8.4" diagonal screen. Input power voltage is single 3.3V for LCD driving. Inverter for backlight is not included in this module. General specifications are summarized in the following table: ITEM SPECIFICATION 170.9(H) 128.2 (V) (8.4-inch diagonal) Display Area (mm) Number of Dots 640 x 3 (H) x 480 (V) Pixel Pitch (mm) 0.267 (H) x 0.267 (V) Color Pixel Arrangement RGB vertical stripe Display Mode Normally white Number of Colors 262,144 Contrast ratio 450 Optimum Viewing Angle(Contrast ratio) 6 o'clock Brightness (cd/m2) 400 Module Size (mm) 199.5 (W) x 149.0 (H) x 11.5 (D) Module Mass (g) Backlight Unit Surface Treatment 380(Typ) CCFL, 2-tubes, replaceable Anti-glare and hard-coating 3H Characteristic value without any note is typical value. The LCD product described in this specification is designed and manufactured for the standard use in OA equipment and consumer products, such as computers, communication equipment, industrial robots, AV equipment and so on. Do not use the LCD product for the equipment that require the extreme high level of reliability, such as aerospace applications, submarine cables, nuclear power control systems and medical or other equipment for life support. Optrex assumes no responsibility for any damage resulting from the use of the LCD product in disregard of the conditions and handling precautions in this specification. If customers intend to use the LCD product for the above items or other no standard items, please contact our sales persons in advance. T-51638D084-FW-A-AA OPTREX CORPORATION Page 2/17 PRELIMINARY 2. ABSOLUTE MAXIMUM RATINGS ITEM SYMBOL MIN. MAX. UNIT Power Supply Voltage for LCD VCC 0 4.0 V Logic Input Voltage VI 0 6.0 V Lamp Voltage VL 0 1500 Vrms Lamp Current IL 0 8.0 mArms Lamp Frequency FL -- 80 kHz Operation Temperature *1) Top 0 50 C Storage Temperature *1) Tstg -20 60 C [Note] *1) Top,Tstg 40C : 85%RH max. without condensation Top,Tstg > 40C : Absolute humidity shall be less than the value of condensation. 85%RH at 40C without 3. ELECTRICAL CHARACTERISTICS Ambient Temperature Ta = (1) TFT- LCD 25C ITEM SYMBOL MIN. TYP. MAX. UNIT Remarks Power Supply Voltages for LCD VCC 3.0 3.3 3.6 Power Supply Currents for LCD ICC -- (240) (400) Permissive input ripple Voltage VRP -- -- 100 Logic Input Voltage High VIH 2.4 -- 5.5 V VCC=MAX Low VIL 0 -- 0.8 V VCC=MIN Note A) (See next page) Note B) mA (See next page) mVp-p VCC=+3.3V V (2) Backlight Ta = 25C ITEM SYMBOL MIN. TYP. MAX. UNIT Remarks Lamp Voltage VL -- 450 -- Vrms IL = 6.0 mArms Lamp Current IL -- 6.0 -- mArms *1) Lamp Frequency FL 30 -- 60 kHz *2) Starting Lamp Voltage VS 670 -- -- Vrms Lamp Life Time LT 50000 -- -- h *1) Lamp Current measurement method (The current meter is inserted in low voltage line.) CTL LCD Module A CTH CTL Inverter A Power Supply CTH T-51638D084-FW-A-AA OPTREX CORPORATION Page 3/17 PRELIMINARY *2) Lamp frequency of inverter may produce interference with horizontal synchronous frequency, and this may cause horizontal beat on the display. Therefore, please adjust lamp frequency, and keep inverter as far from module as possible or use electronic shielding between inverter and module to avoid the interference. [Note] A) Power and signals sequence: t1 10 ms 400 ms t5 0 < t2 50 ms 200 ms t6 0 < t3 50 ms 0 t7 0 t4 50 ms VCC 3.0 V 3.0 V data 2.2 V 0.5 V 0.5 V t1 t3 t4 t2 t5 VL t6 t7 Data: RGB DATA, DCLK, HD, VD, DENA , VCC-dip conditions: 1) When 2.4 V VCC < 3.0 V, td 10 ms 2) When VCC < 2.4 V VCC-dip conditions should also follow the power and signals sequence. 3.0 V 2.4 V VCC td B) Typical current condition: 64- gray- bar-pattern 480 line mode VCC = +3.3 V, fH=31.5 kHz, fV=60 Hz, fCLK= 25 MHz T-51638D084-FW-A-AA OPTREX CORPORATION Page 4/17 PRELIMINARY 4. INTERFACE PIN CONNECTION CN 1(INTERFACE SIGNAL) Used connector: DF9B-31P-1V(Hirose) Corresponding connector: DF9B-31S-1V(Hirose) Pin No. Symbol Function 1 GND 2 DCLK Clock signal for sampling catch data signal 3 HD Horizontal sync signal 4 VD Vertical sync signal 5 GND 6 R0 Red data signal(LSB) 7 R1 Red data signal 8 R2 Red data signal 9 R3 Red data signal 10 R4 Red data signal 11 R5 Red data signal(MSB) 12 GND 13 G0 Green data signal(LSB) 14 G1 Green data signal 15 G2 Green data signal 16 G3 Green data signal 17 G4 Green data signal 18 G5 Green data signal(MSB) 19 GND 20 B0 Blue data signal(LSB) 21 B1 Blue data signal 22 B2 Blue data signal 23 B3 Blue data signal 24 B4 Blue data signal 25 B5 Blue data signal(MSB) 26 GND 27 DENA Data enable signal(to settle the viewing area) 28 VCC 3.3 V Power Supply 29 VCC 3.3 V Power Supply 30 TEST This pin should be open. Test signal output for only internal test use. 31 REV Reverse scan control. L = Normal, H = Reverse *) The shielding case is connected with GND CN 2 , CN 3 (BACKLIGHT) Backlight-side connector: BHR-02(8.0)VS-1N(JST) Inverter-side connector: SM02(8.0)B-BHS(JST) Pin No. Symbol Function 1 CTH VBLHHigh Voltage 3 CTL VBLLLow Voltage [Note] VBLH-VBLL = VL T-51638D084-FW-A-AA OPTREX CORPORATION Page 5/17 PRELIMINARY 5. INTERFACE TIMING (1) Timing Specifications ITEM DCLK SYMBOL MIN. TYP. MAX. UNIT Frequency fCLK 20 25 30 MHz Period tCLK 33.3 40 50 ns Low Width tWCL 10 -- -- ns High Width tWCH 10 -- -- ns tDS 5 -- -- ns tDH 5 -- -- ns Horizontal Active Time tHA 640 640 640 tCLK Horizontal Front Porch tHFP 0 16 -- tCLK Horizontal Back Porch tHBP 7 144 -- tCLK Vertical Active Time tVA 480 480 480 tH Vertical Front Porch tVFP 1 10 -- tH Vertical Back Porch tVBP 8 35 -- tH Frequency fH 27 31.5 38 kHz Period tH 26.3 31.7 37.0 ms Low Width tWHL 5 96 -- tCLK Frequency fV 55 60 70 Hz Period tV 14.2 16.7 18.2 ms tWVL 2 2 -- tH DATA Set up time (R,G,B,DENA, Hold time HD, VD) DENA HD VD Low Width [Note] 1) DATA is latched at fall edge of DCLK in this timing specification. 2) Polarities of HD and VD are negative in this specification. 3) DENA (Data Enable) should always be positive polarity as shown in the timing specification. 4) DCLK should appear during all invalid period, and HD should appear during invalid period of frame cycle. T-51638D084-FW-A-AA OPTREX CORPORATION Page 6/17 PRELIMINARY (2) Timing Chart a. Pixel Timing Chart tCLK tWCH tWCL DCLK 2.0V 0.8V tD tD DATA(R,G,B), DENA, HD, VD 2.0V V0.8V V b. Horizontal Timing Chart DCLK First Data DATA (R,G,B) 1 Invalid Data 2 3 639 640 Invalid Data Last Data tHFP tHBP tHA DENA tH=1/fH tWHL HD c. Vertical Timing Chart HD Invalid Data LINE DATA tVFP tVBP 1 2 3 479 480 Invalid Data tVA DENA tV=1/fV tWVL VD T-51638D084-FW-A-AA OPTREX CORPORATION Page 7/17 PRELIMINARY (3) Color Data Assignment R DATA COLOR INPUT DATA R5 R4 R3 R2 G DATA R1 MSB R0 G5 G4 G3 G2 B DATA G1 LSB MSB G0 B5 B4 B3 B2 B1 LSB MSB B0 LSB BLACK 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 RED(63) 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 GREEN(63) 0 0 0 0 0 0 1 1 1 1 1 1 0 0 0 0 0 0 BASIC BLUE(63) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 COLOR CYAN 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 MAGENTA 1 1 1 1 1 1 0 0 0 0 0 0 1 1 1 1 1 1 YELLOW 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 WHITE 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 RED(0) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 RED (1) 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 RED(2) 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 RED (62) 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 RED(63) 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 GREEN(0) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 GREEN (1) 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 GREEN(2) 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 GREN(62) 0 0 0 0 0 0 1 1 1 1 1 0 0 0 0 0 0 0 GREEN(63) 0 0 0 0 0 0 1 1 1 1 1 1 0 0 0 0 0 0 BLUE(0) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 BLUE(1) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 BLUE(2) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 BLUE(62) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 0 BLUE(63) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 RED GREEN BLUE [Note] 1) Definition of gray scale Color (n) ---n indicates gray scale level. Higher n means brighter level. 2) Data T-51638D084-FW-A-AA OPTREX CORPORATION Page 8/17 PRELIMINARY 1:High, 0: Low 6. BLOCK DIAGRAM BACKLIGHT CN2 S2 S1 Timing Converter G1 Driver(gate) I/F Connector CN1 Power S1920 Driver(source) Timing signal Display data G2 TFT-LCD G480 Power Supply Circuit BACKLIGHT CN3 BACKLIGHT CCFL CN2,CN3 1 3 T-51638D084-FW-A-AA OPTREX CORPORATION Page 9/17 PRELIMINARY 7. MECHANICAL SPECIFICATIONS (1) Front Side Tolerance is 0.5mm unless noted. T-51638D084-FW-A-AA OPTREX CORPORATION Page 10/17 PRELIMINARY (2) Rear Side Tolerance is 0.5mm unless noted. [Note] We recommend you referring to the detailed drawing for your design. Please contact our company sales representative when you need the detailed drawing. T-51638D084-FW-A-AA OPTREX CORPORATION Page 11/17 PRELIMINARY 8. OPTICAL CHARACTERISTICS Ta = 25C, VCC = 3.3 V, Input Signals: Typ. Values shown in Section 5 ITEM SYMBOL CONDITION MIN. TYP. MAX. UNIT Remark s -- 450 -- -- *1)*3) CR q = f = 0 Luminance Lw q = f = 0 -- 400 -- cd/m Response Time tr q = f = 0 -- 10 -- ms *3)*4) tf q = f = 0 -- 25 -- ms *3)*4) CR 10 -- -65~65 -- *3) *3) -- *3) Contrast Ratio Viewing Horizontal f Angle Vertical q -- -60~50 -- Rx -- (0.546) -- Ry -- (0.320) -- Gx -- (0.313) -- -- (0.519) -- Bx -- (0.142) -- By -- (0.134) -- Wx -- (0.313) -- Wy -- (0.324) -- Red Color Green Coordinates Gy Blue White q = f = 0 2 *2)*3) [Note] These items are measured using CS1000(MINOLTA) for color coordinates, and CS1000 or BM5A(TOPCON) for others under the dark room condition (no ambient light) after more than 30 minutes from turning on the lamp unless noted. Condition: IL = 6.0 mArms, FL = 50kHz *1) Definition of Contrast Ratio CR=ON (White) Luminance / OFF(Black) Luminance: average of 5 points *2) Definition of Luminance Lw= ON (White) Luminance: average of 5 points (1,1) 120 160 320 480 1 2 5 240 3 4 360 (640,480) MEASUREMENT POINT T-51638D084-FW-A-AA OPTREX CORPORATION Page 12/17 PRELIMINARY *3) Definition of Viewing Angle( q , f) *4) Definition of Response Time White 90% 90% Luminance 10% Black 10% tr T-51638D084-FW-A-AA OPTREX CORPORATION tf Page 13/17 PRELIMINARY 9. RELIABILITY TEST CONDITION (1) Temperature and Humidity TEST ITEM CONDITIONS HIGH TEMPERATURE HIGH HUMIDITY OPERATION 40C, 90%RH, 240 h HIGH TEMPERATURE STORAGE 60C, 96 h LOW TEMPERATURE STORAGE -20C, 96 h THERMAL SHOCK(NON-OPERATION) BETWEEN -20C (1h) and 60C(1h), 5 CYCLES (2) Shock & Vibration ITEM CONDITIONS Shock level: 1470m/s2 (150G) SHOCK Waveform: half sinusoidal wave, 2ms (NON-OPERATION) Number of shocks: one shock input in each direction of three mutually perpendicular axis for a total of six shock inputs Vibration level: 9.8m/s2 (1.0G)(Zero to Peak) Waveform: sinusoidal VIBRATION Frequency range: 5 to 500Hz (NON-OPERATION) Frequency sweep rate: 0.5 octave /min Duration: one sweep from 5 to 500 Hz in each of three mutually perpendicular axis(each x,y,z axis: 1 hour, total 3 hours) (3) Judgment standard The judgment of the above tests should be made as follow: Pass: Normal display image with no obvious non-uniformity and no line defect. Partial transformation of the module parts should be ignored. Fail: No display image, obvious non-uniformity, or line defects. T-51638D084-FW-A-AA OPTREX CORPORATION Page 14/17 PRELIMINARY 10. HANDLING PRECAUTIONS FOR TFT-LCD MODULE Please pay attention to the followings in handling TFT-LCD products; (1) ASSEMBLY PRECAUTION a. Please use the mounting hole on the module in installing and do not bending or wrenching LCD in assembling. And please do not drop, bend or twist LCD module in handling. b. Please design display housing in accordance with the following guide lines. (a) Housing case must be designed carefully so as not to put stresses on LCD all sides and not to wrench module. The stresses may cause non-uniformity even if there is no nonuniformity statically. (b) Keep sufficient clearance between LCD module back surface and housing when the LCD module is mounted. Approximately 1.0mm of the clearance in the design is recommended taking into account the tolerance of LCD module thickness and mounting structure height on the housing. (c) When some parts, such as, FPC cable and ferrite plate, are installed underneath the LCD module, still sufficient clearance is required, such as 0.5mm. This clearance is, especially, to be reconsidered when the additional parts are implemented for EMI countermeasure. (d) Design the inverter location and connector position carefully so as not to give stress to lamp cable, or not to interface the LCD module by the lamp cable. (e) Keep sufficient clearance between LCD module and the others parts, such as inverter and speaker so as not to interface the LCD module. Approximately 1.0mm of the clearance in the design is recommended. c. Please do not push or scratch LCD panel surface with anything hard. And do not soil LCD panel surface by touching with bare hands. (Polarizer film, surface of LCD panel is easy to be flawed.) d. Please do not press any parts on the rear side such as source TCP, gate TCP, control circuit board and FPCs during handling LCD module. If pressing rear part is unavoidable, handle the LCD module with care not to damage them. e. Please wipe off LCD panel surface with absorbent cotton or soft cloth in case of it being soiled. f. Please wipe off drops of adhesives like saliva and water on LCD panel surface immediately. They might damage to cause panel surface variation and color change. g. Please do not take a LCD module to pieces and reconstruct it. Resolving and reconstructing modules may cause them not to work well. h. Please do not touch metal frames with bare hands and soiled gloves. A color change of the metal frames can happen during a long preservation of soiled LCD modules. i. Please pay attention to handling lead wire of backlight so that it is not tugged in connecting with inverter. T-51638D084-FW-A-AA OPTREX CORPORATION Page 15/17 PRELIMINARY j. Be sure to connect the cables and the connectors correctly. k. Please connect the metal frame of LCD module to GND in order to minimize the effect of external noise and EMI. (2) OPERATING PRECAUTIONS a. Please be sure to turn off the power supply before connecting and disconnecting signal input cable. b. Please do not change variable resistance settings in LCD module. They are adjusted to the most suitable value. If they are changed, it might happen LCD does not satisfy the characteristics specification. c. LCD backlight takes longer time to become stable of radiation characteristics in low temperature than in room temperature. d. A condensation might happen on the surface and inside of LCD module in case of sudden change of ambient temperature. e. Please pay attention not to display the same pattern for very long time. Image might stick on LCD. Even if image sticking happens, it may disappear as the operation time proceeds. f. Please obey the same safe instructions as ones being prepared for ordinary electronic products. (3) PRECAUTIONS WITH ELECTROSTATICS a. This LCD module use CMOS-IC on circuit board and TFT-LCD panel, and so it is easy to be affected by electrostatics. Please be careful with electrostatics by the way of your body connecting to the ground and so on. b. Please remove protection film very slowly from the surface of LCD module to prevent from electrostatics occurrence. (4) STORAGE PRECAUTIONS a. Please do not leave the LCDs in the environment of high humidity and high temperature such as 60C90%RH. b. Please do not leave the LCDs in the environment of low temperature; below -20C. (5) SAFETY PRECAUTIONS a. When you waste damaged or unnecessary LCDs, it is recommended to crush LCDs into pieces and wash them off with solvents such as acetone and ethanol, which should later be burned. b. If any liquid leaks out of a damaged glass cell and comes in contact with the hands, wash off thoroughly with soap and water. c. Be sure to turn off the power supply when inserting or disconnecting the cable. T-51638D084-FW-A-AA OPTREX CORPORATION Page 16/17 PRELIMINARY d. Inverter should be designed carefully so as not to keep working in case of detecting over current or open circuit on the lamp. (6) OTHERS a. A strong incident light into LCD panel might cause display characteristics changing inferior because of polarizer film, color filter, and other materials becoming inferior. Please do not expose LCD module direct sunlight and strong UV rays. b. Please pay attention to a panel side of LCD module not to contact with other materials in preserving it alone. c. For the packaging box, please pay attention to the followings; (a) Packaging box and inner case for LCD are designed to protect the LCDs from the damage or scratching during transportation. Please do not open except picking LCDs up from the box. (b) Please do not pile them up more than 6 boxes. (They are not designed so.) And please do not turn over. (c) Please handle packaging box with care not to give them sudden shock and vibrations. And also please do not throw them up. (d) Packaging box and inner case for LCDs are made of cardboard. So please pay attention not to get them wet. (Such like keeping them in high humidity or wet place can occur getting them wet.) T-51638D084-FW-A-AA OPTREX CORPORATION Page 17/17