Machine Safety Switches (R) SI-LM40 Series Limit Switch Style with In-Line Actuator Features * Positive opening safety contacts (IEC 60947-5-1) (not dependent upon springs) * Standard limit switch metal housing (EN 50041) *Choose either of two stainless steel actuator types: - Rigid in-line - Flexible in-line * Protective Earth Terminal (IEC 60947-1) NOTE: This symbol for a positive-opening safety contact (IEC 60947-5-1) is used in the switching diagrams to identify the point in actuator travel where the normally closed safety contact is fully open. Models Contact Configuration (Actuator Engaged) SI-LM40MKHE SI-QM-SSA Straight, Rigid, In-Line SI-LM40MKHFE SI-QM-SMFA Right-angle, Flexible, In-Line SI-LM40MKHF SI-QM-SSA Straight, Rigid, In-Line SI-LM40MKHFF SI-QM-SMFA Right-angle, Flexible, In-Line Engaged SI-LM40KHD with Metal Housing 11 12 11 23 24 23 12 24 0 (0) 9 (0.35) 10 (0.39) 11 (0.43) Disengaged 40 (1.58) mm (in) Safety Monitor SI-LM40MKHFD SI-QM-SMFA Right-angle, Flexible, In-Line (Actuator Removed) Engaged SI-LM40KHE with Metal Housing 11 12 11 12 21 22 21 22 Disengaged Engaged SI-LM40KHF with Metal Housing 15 16 40 (1.58) mm (in) 25 26 25 26 34 33 34 Disengaged Feb07/06 2013 0 (0) 10.5 (0.39) 11 (0.43) 12 (0.47) 16 33 A kit contains an interlock and actuator. Individual interlock bodies or actuators are for replacement purposes only. See page 7 and the Warning on page 8. Printed in USA 15 0 (0) 11 (0.43) 14 (0.55) Safety Safety SI-QM-SSA Straight, Rigid, In-Line Switching Diagram Safety Safety Monitor SI-LM40MKHD Contact Configuration 11-12 23-24 Interlock Body 11-12 21-22 Actuator Type 15-16 25-26 33-34 Kit Model Contacts: Open 41 (1.62) mm (in) Closed Transition P/N 49372 rev. D E Machine Safety Switch - SI-LM40 Series Limit Switch Style Important Information Regarding the Use of Safety Switches In the United States, the functions that Banner safety switches are intended to perform are regulated by the Occupational Safety and Health Administration (OSHA). Whether or not any particular safety switch installation meets all applicable OSHA requirements depends upon factors that are beyond the control of Banner Engineering Corp. These factors include the details of how the safety switches are applied, installed, wired, operated, and maintained. Banner Engineering Corp. has attempted to provide complete application, installation, operation, and maintenance instructions. This information is found in the instruction manual packaged with each safety switch. In addition, we suggest that any questions regarding the use or installation of safety switches be directed to the factory applications department at the telephone numbers or address shown below. Banner Engineering Corp. recommends that safety switches be applied according to the guidelines set forth in international (ISO/IEC) standards listed below. Specifically, Banner Engineering Corp. recommends application of these safety switches in a configuration which meets safety category 4, per ISO 13849 (EN954-1). In addition, the user of Banner safety switches has the responsibility to ensure that all local, state, and national laws, rules, codes, and regulations relating to the use of Banner safety switches in any particular application are satisfied. Extreme care is urged that all legal requirements have been met and that all installations and maintenance instructions are followed. Toll Free: Email: Address: Application Assistance 1-888-3-SENSOR (1-888-373-6767) sensors@bannerengineering.com 9714 Tenth Avenue North Minneapolis, MN 55441 U.S. Regulations Applicable to Use of Banner Safety Switches OSHA Code of Federal Regulations: Title 29, Parts 1900 to 1910 Available from: Superintendent of Documents Government Printing Office P.O. Box 371954 Pittsburgh, PA 15250-7954 Tel: 202-512-1800 U.S. Standards Applicable to Use of Banner Safety Switches ANSI B11 "Standards for Construction, Care, and Use of Machine Tools" Available from: Safety Director AMT--The Association for Manufacturing Technology 7901 Westpark Drive McLean, VA 22102 Tel: 703-893-2900 Applicable European and International Standards ISO/TR 12100-1 "Safety of Machinery--Basic Concepts, General Principles for Design" (EN292-18-2) ISO 13852 (EN 294) "Safety of Machinery--Safety Distances to Prevent Danger Zones Being Reached by the Upper Limbs" ISO 13853 (EN 811) "Safety of Machinery--Safety Distances to Prevent Danger Zones Being Reached by the Lower Limbs" ISO 13849 (EN 954-1) "Safety of Machinery--Safety Related Parts of Control Systems" ISO 13855 (EN 999) "Safety of Machinery--The Positioning of Protective Equipment in Respect to Approach Speeds of Parts of the Human Body" ISO 14119 (EN 1088) "Safety of Machinery--Interlocking Devices Associated with Guards--Principles for Design and Selection" IEC/EN 60204-1 "Safety of Machinery--Electrical Equipment of Machines" IEC/EN 60947-5-1 "Low Voltage Switchgear--Electromechanical Control Circuit Devices" Available from: P/N 49372 rev. ED Global Engineering Documents 15 Inverness Way East Englewood, CO 80112-5704 Phone: 1-800-854-7179 Fax: 303-397-2740 Banner Engineering Corp. * Minneapolis, MN U.S.A. www.bannerengineering.com * Tel: 763.544.3164 Machine Safety Switch - SI-LM40 Series Limit Switch Style Mechanical Installation Round (5 mm) holes for permanent installation (2X) Remove to access wiring chamber (2X) Slotted holes for initial alignment only (2X) Figure 1. Features The actuator head may be rotated, if desired, to any of four positions, in 90 increments. To reposition the actuator head, unscrew the four mounting bolts, turn the head to the desired position, and re-tighten the bolts (see Figure 2). All mounting hardware is supplied by the user. The fasteners must be of sufficient strength to guard against incidental breakage. Use of permanent fasteners or locking hardware is recommended to prevent loosening or displacement of the actuator and switch body. The mounting holes in the switch body accept M5 (#10) screws. There are four holes on a standard limit switch mounting pattern of 30 x 60 millimeters. The two mounting holes on the actuator are spaced 20 millimeters apart. The grommet and sleeve design allows a small amount of movement (i.e., misalignment) when the actuator engages the switch body. The sleeves accept M4.5 (#8) screws. Position the switch, with its actuator fully engaged, in the mounting location and mark the mounting holes. Fasten the switch body and the actuator in place. The non-adjustable (rigid) in-line actuators includes floating sleeves in the mounting holes to allow some forgiveness for switch-to-actuator alignment. Take care to not over-tighten the actuator fasteners so as to allow this movement. After the mounting hardware is secure, check the actuator/switch engagement for misalignment and binding. IMPORTANT: A safety switch must be installed in a manner which discourages tampering or defeat. Mount switches to prevent bypassing of the switching function at the terminal chamber. A switch and its actuator must never be used as a mechanical stop. Overtravel may cause damage to switch. 90 Figure 2. Actuator head may be rotated in 90 increments. WARNING ... It must not be possible for personnel to reach any hazard point through an opened guard (or any opening) before hazardous machine motion has completely stopped. Please reference OSHA CFR 1910.217 and ANSI B11 standards (see page 2) for information on determining safety distances and safe opening sizes for your guarding devices. Banner Engineering Corp. * Minneapolis, MN U.S.A. www.bannerengineering.com * Tel: 763.544.3164 E P/N 49372 rev. D Machine Safety Switch - SI-LM40 Series Limit Switch Style Electrical Installation CAUTION . . . Electrical Installation Access to the Wiring Chamber Two safety switches must be used for each interlock guard to achieve control reliability or Safety Category 4 (per ISO 13849-1, EN 954-1) of a machine stop circuit. Use of only one safety switch per interlock guard is not recommended. The wiring chamber is accessed via a cover plate. The metal switch body uses two screws to hold the cover plate on. A conduit adapter is supplied to convert the M20 x 1.5 thread to 1/2"-14 NPT. An accessory cable gland which fits the M20 x 1.5 thread is available (see page 7). Connection to a Machine Two types of contacts are offered. The NC contact is the safety contact, which is closed (i.e., it conducts) when the actuator is engaged. The NO contact is considered a monitoring contact, which should not be used for safety switching. As illustrated in Figure 3, a normally closed safety contact (i.e., a safety contact that is closed when the actuator is engaged) from each of two safety switches per interlock guard must connect to a 2-channel safety module or safety interface in order to achieve a control reliable interface to the master stop control elements of a machine. Examples of appropriate safety modules include 2-channel emergency stop (E-stop) safety modules and gate monitor safety modules. In addition, normally-closed safety contacts from each of the two safety switches should be connected to the two separate inputs of a 2-channel safety module or safety interface, as illustrated in Figure 6. This is required to provide monitoring for safety switch contact failure, and to provide the necessary reset routine, as required by IEC 60204-1 and NFPA 79 machine safety standards. Two functions of the safety module or safety interface are: 1. to provide a means of monitoring the contacts of both safety switches for contact failure, and to prevent the machine from restarting if either switch fails; and WARNING . . . Series 2. to provide a reset routine after closing the guard and returning the safety switch contacts to their closed position. This prevents the controlled machinery from restarting by simply reinserting the safety switch actuators. This necessary reset function is required by ANSI B11 and NFPA 79 machine safety standards. Use only a positively driven, normally closed safety contact from each switch for connection to the safety module. The normally open contact may be used for control functions that are not safety-related. A typical use is to communicate with a process controller. Refer to the installation instructions provided with the safety modules for more information regarding the interface of the safety module to the machine stop control elements. Safety Switch #1 Safety Switch #2 11/15 12/16 11/15 12/16 Input Channel #1 Input Channel #2 2-channel Safety Module (2-channel E-stop Module 2-channel Gate Monitor Module, etc.) Connection of Safety Interlock Switches Monitoring multiple guards with a series connection of multiple safety interlock switches is not a Safety Category 4 Application (per ISO 13849-1, EN 954-1). A single failure may be masked or not detected at all. When such a configuration is used, procedures must be performed regularly to verify proper operation of each switch. Single gate or guard NOTE: Refer to the installation instructions provided with the safety module for information regarding the interface of the safety module to the machine stop control elements. Figure 3. Connect two redundant safety switches per interlock guard to an appropriate 2-channel input safety module. P/N 49372 rev. DE Banner Engineering Corp. * Minneapolis, MN U.S.A. www.bannerengineering.com * Tel: 763.544.3164 Machine Safety Switch - SI-LM40 Series Limit Switch Style Periodic Checks Safety switches should be checked at each shift change or machine setup by a designated person (see below) for: 1. Breakage of the switch body or actuator, 2. Good alignment and full engagement of the actuator with the receptor, 3. Confirmation that the safety switch is not being used as an end stop, 4. Loosening of the switch or actuator mounting hardware, and 5. Verification that it is not possible to reach any hazard point through an opened guard (or any opening) before hazardous machine motion has completely stopped. In addition, a qualified person should check for the following on a periodic schedule, determined by the user, based upon the severity of the operating environment and the frequency of switch actuations: 1. Check the wiring chamber for signs of contamination. 2. Check the contacts for signs of deterioration or damage. 3. Inspect the electrical wiring for continuity and damage. 4. Verify that wiring conforms to the instructions on page 4 of this data sheet. A designated person is identified in writing by the employer as being appropriately trained to perform a specified checkout procedure. A qualified person possesses a recognized degree or certificate or has extensive knowledge, training, and experience to be able to solve problems relating to the safety switch installation. Repairs o not attempt any repairs to the switch. It contains no field-replaceable D components. Return the switch to the factory for warranty repair or replacement. If it ever becomes necessary to return a switch to the factory, please do the following: 1. Contact the Banner applications engineering department at the number or address listed on the back cover. They will attempt to troubleshoot the system from your description of the problem. If they conclude that a component is defective, they will issue an RMA (Return Merchandise Authorization) number for your paperwork, and give you the proper shipping address. 2. Pack the switch carefully. Damage which occurs in shipping is not covered by warranty. Banner Engineering Corp. * Minneapolis, MN U.S.A. www.bannerengineering.com * Tel: 763.544.3164 E P/N 49372 rev. D Machine Safety Switch - SI-LM40 Series Limit Switch Style Specifications Contact Rating 10A @ 24V ac, 10A @110V ac, 6A @ 230V ac 6A @24V dc 2.5 kV max. transient tolerance NEMA A300 P300 European Rating Utilization categories: AC15 and DC13 40-60 Hz Switches with 1 and 2 contact pairs: Ui = 500V ac Ith = 10A Ue V Ie/AC-15 A Ie/AC-13 A 24 10 6 110 10 1 230 6 0.4 Contact Material Silver-nickel alloy Maximum Switching Speed 50 operations per minute Maximum Actuator Speed 1.5 m/second (5'/second) Minimum Actuator Engagement Radius Rigid actuators: 400 mm (16") Flexible actuators: 150 mm (6") Actuator Extraction Force 10 N (2.2 lbf) Short Circuit Protection 6 amp Slow Blow, 10 amp Fast Blow. Recommended external fusing or overload protection. Mechanical Life 1 million operations Wire Connections Screw terminals with pressure plates accept the following wire sizes - Stranded and solid: 20 AWG (0.5 mm2) to 16 AWG (1.5 mm2) for one wire Stranded: 20 AWG (0.5 mm2) to 18 AWG (1.0 mm2) for two wires Cable Entry M20 x 1.5 threaded entrance. Adapter supplied to convert M20 x 1.5 to 1/2" - 14 NPT threaded entrance Construction Aluminum alloy die-cast housing Environmental Rating IEC IP65 Operating Conditions Temperature: -30 to +80 C (-22 to +176 F) Weight 0.34 kg (0.75 lb) Certifications P/N 49372 rev. DE Banner Engineering Corp. * Minneapolis, MN U.S.A. www.bannerengineering.com * Tel: 763.544.3164 Machine Safety Switch - SI-LM40 Series Limit Switch Style Dimensions Switch Dimensions Actuator Dimensions Model SI-QM-SSA 32.0 mm (1.26") L* 80.0 mm (3.15") 41.3 mm (1.63") 11.6 mm (0.46") 20.0 mm (0.79") 37.2 mm (1.46") 2.0 mm (0.08") 2 x o4.8 mm (0.19") 118.8 mm (4.68") 60.0 mm (2.36") 1/2"-14 NPT Adapter is Supplied 7.5 mm (0.30") 77.5 mm (3.05") 4 x o5.2 mm (0.20") M20 x 1.5 mm (0.06") 15 mm (0.59") 40.0 mm (1.57") 30.0 mm (1.18") 33.0 mm (1.30") Model SI-QM-SMFA Actuator Model SI-QM-SSA 42.0 mm (1.65") SI-QM-SMFA *Length L 81.4 - 89.4 mm (3.20" - 3.52") 82.4 - 90.4 mm (3.24" - 3.56") 29 mm (1.1") 41 mm (1.6") 81 mm (3.2") o 5.5 mm (0.22") CL 40 mm (1.6") 50 mm (2.0") Accessories Cable Glands Size Model Used with Switch Models For Cable Diameters Dimensions 35.5 mm (1.40") M20 x 1.5 Metal SI-QM-CGM20 All 5.0 to 12.0 mm (0.20" to 0.47") 24.0 mm (0.94") M20 x 1.5 Replacement Parts Description Model* Used with Switch Models Thread Conversion Dimensions 23.0 mm (0.91") 1/2"-14 NPT Metal Conduit Adaptor SI-QM-M20 All M20 x 1.5 to 1/2"-14 NPT 1/2"-14 NPT Internal Thread 24.0 mm (0.94") M20 x 1.5 O-ring *NOTE: One conduit adapter is supplied with each switch. Banner Engineering Corp. * Minneapolis, MN U.S.A. www.bannerengineering.com * Tel: 763.544.3164 E P/N 49372 rev. D Machine Safety Switch - SI-LM40 Series Limit Switch Style Accessory Actuators Description Model Used with Switch Models Dimensions 40.0 mm (1.60") 9.6 mm (0.40") Rigid in-line metal actuator used for doors or covers. Slide-bolt design for use in heavy-duty applications where alignment is difficult to maintain. 20.0 mm (0.80") SI-QM-SB All 59.0 mm (2.30") 3.0 mm (0.13") 4x O5.5 mm (0.20") 42.0 mm (1.70") 38.0 mm (1.50") O8 mm hole for locking bolt in the open position 31.0 mm (1.20") 20.0 mm (0.80") 47.0 mm (1.90") 100.0 mm (3.9") 140.0 mm (5.50") WARNING . . . Spare actuators must NEVER be used to bypass or otherwise defeat the protective function of a safety switch. To do so may create an unsafe situation which could lead to serious injury or death. Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. (R) WARRANTY: Banner Engineering Corp. warrants its products to be free from defects for one year. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period. This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either expressed or implied. P/N 49372 rev. D Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN USA 55441 * Phone: 763.544.3164 * www.bannerengineering.com * Email: sensors@bannerengineering.com