MANUAL MOTOR STARTERS
MAGNETIC CONTACTORS
USEH530a
Advanced Motor Protection and ControlFuji DUO series
Fuji's new motor control system for the international market.
Manual Motor Starters that provide
optimal protection by integrating the
functions of a molded case circuit
breaker and thermal overload relay
into a highly compact unit.
DUO SERIES
Manual motor starters (MMS)
Contactors and thermal overload relays
SC-M series
SC-E series TK-E series
Provide the ability to configure
combination starters for
compact, reliable motor
protection by combining a
manual motor starter and a
magnetic contactor.
Combination starters
Compact magnetic contactors and small
capacity motor control for 3 to 5HP,
480VAC.
The DUO series adds a new family of compact, high-performance combination starters to manual motor starters BM3
series, magnetic contactors SC-M and SC-E series and thermal overload relays TK-E series to form a complete line-up
of motor control products.
ULTIMATE COST SAVING SOLUTION
Responding to today's market needs, Fuji DUO series was designed to provide various distinctive features.
Rated current: 0.16 to 32A, 10 to 63A
Short circuit current rating : 22, 50kA 480VAC
Width: 45mm, 55mm
Rated capacity: AC-3 3 to 5HP, 480VAC
Width: 45mm
Magnetic contactors and thermal
overload relays featuring terminals with
finger protection for 5 to 100HP.
Rated capacity: AC-3 5 to 100HP
Width: 43,54,67mm (5 to 50HP)
88,100,115mm (60 to 100HP)
BM3 series
FUJI meets emerging needs with a new form of motor protection.
RESPONSE TO THE INTERNATIONAL MARKET SAFETY AND ECOLOGICAL CONSIDERATION
1
•The number of components like Circuit
Breakers can be reduced. (See page 4 to 7
for detail.)
•Combination starters combined with manual
motor starters and contactors, provides 52%
reduction for monting space and 90% reduction
for wiring work to make a control panel.
•Short-circuit protective coordination
between protective devices and the
equipment to be protected.
•Conformance to UL including Type E, Type F,
CSA, IEC and other international standards.
•Application of international standards in
safety features such as terminals with
finger protection.
•Use of recycled materials to help conserve
the environment and save resources.
2
Manual motor starters BM3 series
Conforming to international standards and combining compactness with high breaking performance,
this versatile series features leading-edge motor protection.
Magnetic contactors SC-M and SC-E series
A full line-up consisting of the mini-contactor SC-M series for 3 to 5HP, 480VAC use and the SC-E series
for 5 to 100HP 480VAC use.
Circuit breaker functions
• Short-circuit protection
• Overcurrent protection
• Line protection
Thermal overload relay functions
• Overload protection
• Phase-loss protection
• Rated current adjustment
Ambient temperature compensation
Manual motor starter advantages
Compactness
Reduction in wiring work
Standards
Approved
Ecological design
Mounting space: MCCB + Thermal overload relay: 100%
MMS: 43% (57% reduction)
MCCB + Contactor + Thermal overload relay: 100%
MMS + Contactor: 50% (50% reduction)
• IEC 60947-1, 60947-2, 60947-4-1, UL 508, CSA C22.2 No.14
• cUL (File No. E163944, E211710), TÜV (R205062B)
• Recyclable thermoplastic resin used in plastic parts
• Indication of materials used
• Cadmium-free contacts
Molded case circuit breaker and thermal overload relay functions integrated into a highly compact unit.
• Finger protection standard • Lug terminal
SC-M series SC-E series
SC-M01, M02 SC-E02 to E05 SC-E1 to E2S SC-E3, E4
45mm
54mm
67mm
43mm
3
52% reduction
Space-saving, reliable motor protection achieved by combining a manual motor starter and magnetic contactor.
Contactor
Thermal overload relay
• Overload protection
• Phase-loss protection
Motor
Motor
MCCB MCCB
Combination starter
(MMS+Contactor)
• Short-circuit protection
• Overload protection
• Phase-loss protection
MCCB
• Short-circuit protection
Wiring work
+
Mounting space
90% reduction
Conventional system New system using an MMS
For control panel
For control panel
MMS
BM3R series
Contactor
Link module Link module
Base
plate
Contactor
SC-M series
MMS
Contactor
SC-E series
MMS
BM3V series
Combination starters can be easily configured with a manual motor starter, magnetic contactor and other parts.
Combination of manual motor starters and magnetic contactors
A line-up that aims to set a new world standard for compactness, high performance,
and utility in combination starters.
4
Motor
MMS
MCCB
Branch Circuit
Protection Devices
(Fuses or Circuit Breakers)
Motor
MMS
MCCB
Branch Circuit
Protection Devices
(Fuses or Circuit Breakers)
MCCB
Branch Circuit
Protection Devices
(Fuses or Circuit
Breakers)
Standard circuit Group Installation circuit
Fuji proposes ultimate cost saving solution with DUO series
Fuji Manual Motor Starter (MMS) intends to apply for manual motor starting application.
As UL listed manual motor controller per UL508, they provide overload protection but are required to be installed
with short circuit protection devices (Fuses or Circuit Breakers) on the upstream.
However, according to National Electrical Code (NEC), you can save the cost of short circuit protection devices
and can make a smaller panel using DUO series.
The following are case studies for the cost saving use of Fuji DUO series.
Case study 1 : Group Motor Installation
Per NEC430-52 and -53, the combination with a specific rated Fuse or Circuit Breaker allows several motors in a circuit
composition.
Fuji MMS are cUL listed per group installation regulations of NEC.
Two or more motors can be connected to one branch circuit when the MMS is used with a specific current rated branch circuit
protection device (see remarks below).
The advantages of Group Installation are as follows.
- The number of components like Circuit Breakers can be reduced
- The wire size can be reduced by 1/3 - 1/10 under certain conditions
- The area inside the control panel can be minimized
Remarks :
Per NEC regulations, to connect several motors on one branch circuit protection device, note the following conditions (A) or (B)
or (C) and condition (D) listed NEC article 430.53 must be complied.
(A) : Not over 1 horsepower
(B) : If smallest rated motor protected
(C) : Other group installation
(D) : Single motor taps.
For complete details, please refer to NEC book.
45
Case study 2 : Self-Protected Combination Motor Controller / TYPE E and TYPE F
Fuji MMS are cUL listed as a Self-Protected Combination Controller such as Type E and Type F.
To apply MMS as Self-Protected Combination Controller, MMS must be attached to short circuit alarm contact block (BZ0TKUAB).
32A frame type, BM3R series must also be attached to the line side terminal cover (BZ0TCRE) because the Self-Protected
Combination Controller has the clearance and creepage distance requirements as UL489 regulation.
(63A frame type, BM3V series complies with their regulation without terminal cover.)
(1) Combination motor controller, Type E, when only MMS is used.
(Manual Self-Protected Combination Motor Controller according to UL508)
(2) Combination motor controller, Type F, when MMS is used with Fuji SC-E, SC-M contactor.
(Manual Self-Protected Combination Motor Controller + Magnetic contactor according to UL508)
The advantage of a Self-Protected Combination Motor Controller is that it can replace a UL489 Circuit Breaker.
This means that in a motor branch circuit, the UL489 Circuit Breaker upstream can be eliminated.
MMS has a trip function like a Circuit Breaker for the purpose of protection against short-circuit.
Therefore, the number of components can be reduced and will result in saving more space than the ordinary Group Installation.
* The self-protected combination motor controller can be used as branch circuit protection in Motor Circuit only.
They cannot be applied to any other loads such as resistance load.
Group Installation circuit
Motor
MMS
MCCB
Branch Circuit
Protection
Devices
(Fuses or Circuit
Breakers)
Branch Circuit
Protection
Devices
(Fuses or Circuit
Breakers)
Motor
MMS
MCCB
MCCB
Branch Circuit
Protection
Devices
(Fuses or Circuit
Breakers)
Requirements for Type E construction
- Terminal cover (BZ0TCRE) except for BM3V series.
- Short-circuit alarm contact block (BZ0TKUAB) for all MMS.
Example of Type E application
Application as Type E Controller
6
Requirements for Type F construction
- Must be used with contactor for motor control fuction.
- Terminal cover (BZ0TCRE) except for BM3V series.
- Short-circuit alarm contact block (BZ0TKUAB) for all MMS.
Group Installation circuit
Motor
MMS
+ CTT
MCCB
Branch Circuit
Protection
Devices
(Fuses or Circuit
Breakers)
Branch Circuit
Protection
Devices
(Fuses or Circuit
Breakers)
Motor
MMS
+ CTT
MCCB
MCCB
Branch Circuit
Protection
Devices
(Fuses or Circuit
Breakers)
Example of Type F application
Application as Type F Controller
47
Traditional
motor circuit
MMS application Type E, Type F application
Case study 3 : Motor Disconnecting Means
Per NEC 430.102, a disconnecting means must be applied to each controller.
Fuji MMS are also cUL listed as "Suitable as Motor disconnect" and can be applied as a Motor disconnect.
The advantage of using MMS for disconnect means :
- An extra component will not be needed because the MMS has a dual function, which will lead to smaller space requirement
and less components.
A A A
CC
B
D
E
A: Motor Feeder short-
circuit and ground-
fault protection
B: Motor disconnecting
means
C: Motor branch-circuit
short-circuit and
ground-fault
protection
D: Motor controller
E: Motor overload
protection
8
CONTENTS
Contactors SC-M and SC-E series
General information
Quick reference guide
Ordering information and Characteristics
Optional accessories
Dimensions
Instructions
......................................................................
...................................................................
.......................................
.....................................................................
...................................................................................
...................................................................................
Thermal overload relays TK-E series
Quick reference guide and Ordering information
Characteristics
Optional accessories
Dimensions
Instructions
............................
..............................................................................
.....................................................................
...................................................................................
...................................................................................
Combination Starters
Quick reference guide
Optional accessories
...................................................................
.....................................................................
Dimensions ...................................................................................
List price
For BM3 Series Manual Motor Starters
For BM3 Series Manual Motor Starters accessories
For SC-M and SC-E series Contactors and
TK-E series Overload Relay and accessories
..........................................
.......................
............................
For Combination Starters accessories ...........................................
Appendix
Appendix 1 : Construction of combination motor controllers
Appendix 2 : Short circuit coordination comparison
............
........................
Terms and conditions of sale ....................................
Manual Motor Starters
..............................................................................
.......................................
.....................................................................
...................................................................................
...................................................................................
............................................................................
....................................................................................
Quick reference guide
Type E ratings
Ordering information and Characteristics
Optional accessories
Dimensions
Instructions
Busbar systems
Enclosures
................................................................... 9
13
14
15
21
25
26
29
31
32
35
37
40
48
49
50
51
52
54
55
58
60
72
73
75
77
78
78
81
Page
32A Frame types and ratings
Available Not available
Standard breaking capacity
Adjustable thermal-magnetic trip type BM3RSB-
KK01-317
Number of poles 3
Handle type Rocker
Rated current Ie (A) 0.16 to 32
Rated operational voltage Ue (V) 200 to 690
Rated frequency (Hz) 50/60
Rated insulation voltage Ui (V) 690
Rated impulse withstand voltage Uimp (kV) 6
Utilization IEC 60947-2 Circuit breaker Cat. A
category IEC 60947-4-1 Motor starter AC-3
Trip class IEC 60947-4-1 10
Instantaneous trip characteristic 13 le max.
Power loss (total of 3-pole) 7W: In=0.16 to 25A 8.5W: In=32A
Mechanical durability (operations) 100,000: In=0.16 to 25A 70,000: In=32A
Electrical durability (operations) 100,000: In=0.16 to 25A 70,000: In=32A
Max. operations per hour (motor start-up) 25
Phase-loss protection Provided
Trip indicator Provided
Test trip function Provided
Adjustable current range
UL/CSA 3phase HP rating (HP) *2Instantaneous UL/CSA Short circuit
Maximum listed branch
trip current (A) current rating (kA) *3circuit protection *3
Code
*1
Ie: Min.–Max.
(A)
240VAC 480VAC 600VAC Fuse or MCCB (A)
P16 0.1–0.16
In accordance with
Motor full load current
P25 0.16–0.25
P40 0.25–0.4
P63 0.4–0.63
001 0.63–1 .
1P6 1–1.6
2P5 1.6–2.5
004 2.5–4 .
6P3 4–6.3
010 6.3–10
013 9–13
016 11–16
020 14–20
025 19–25
032 24–32
Dimensions (mm) W X H X D 45 X 90 X 66
Mass (g) 350
Optional Auxiliary contact block
accessory Alarm contact block
Auxiliary and alarm contact block
Short-circuit alarm contact block
Shunt trip device
Undervoltage trip device
External operating handle
Standard IEC 60947-1, 60947-2, 60947-4-1, UL 508, CSA C22.2 No.14
2.1 100 50 10 500
3.3 100 50 10 500
5.2 100 50 10 500
8.2 100 50 10 500
1/2 13 100 50 10 500
3/4 3/4 20.8 100 50 10 500
1/2  1/2 1 1-1/2 32.5 100 50 10 500
3/4  3/4 2 3 52 100 50 10 500
1  1-1/2 3 5 81.9 100 50 10 500
2 3 5 7-1/2 130 100 22 10 500
3 3 7-1/2 10 169 100 22 10 500
3 5 10 10 208 100 22 10 500
5 5 10 15 260 50 22 10 500
7-1/2 7-1/2 15 20 325 50 22 10 500
10 10 20 30 416 50 22 10 500
200-
208VAC
220-
240VAC
440-
480VAC
550-
600VAC
Notes: *1 Replace the mark in the part number by current range codes.
*2 The BM3RSB is cUL listed as HP rated motor controllers.
*3 The BM3RSB is cUL listed for group Installation as per NEC430-53(C).
9
Manual Motor Starters
Quick reference guide
32A Frame types and ratings
Available Not available
High breaking capacity
Adjustable thermal-magnetic trip type BM3RHB-
Number of poles 3
Handle type Rotary
Rated current Ie (A) 0.16 to 32
Rated operational voltage Ue (V) 200 to 690
Rated frequency (Hz) 50/60
Rated insulation voltage Ui (V) 690
Rated impulse withstand voltage Uimp (kV) 6
Utilization IEC 60947-2 Circuit breaker Cat. A
category IEC 60947-4-1 Motor starter AC-3
Trip class IEC 60947-4-1 10
Instantaneous trip characteristic 13 le max.
Power loss (total of 3-pole) 7W: In=0.16 to 25A 8.5W: In=32A
Mechanical durability (operations) 100,000: In=0.16 to 25A 70,000: In=32A
Electrical durability (operations) 100,000: In=0.16 to 25A 70,000: In=32A
Max. operations per hour (motor start-up) 25
Phase-loss protection Provided
Trip indicator Provided
Test trip function Provided
UL/CSA 3phase HP rating (HP) *2Instantaneous UL/CSA Short circuit
Maximum listed branch
trip current (A) current rating (kA) *3circuit protection *3
240VAC 480VAC 600VAC Fuse or MCCB (A)
.
.
Dimensions (mm) W X H X D 45 X 90 X 79
Mass (g) 370
Optional Auxiliary contact block
accessory Alarm contact block
Auxiliary and alarm contact block
Short-circuit alarm contact block
Shunt trip device
Undervoltage trip device
External operating handle
Standard IEC 60947-1, 60947-2, 60947-4-1, UL 508, CSA C22.2 No.14
AF01-42
10
Manual Motor Starters
Quick reference guide
In accordance with
Motor full load current
2.1 100 50 10 500
3.3 100 50 10 500
5.2 100 50 10 500
8.2 100 50 10 500
1/2 13 100 50 10 500
3/4 3/4 20.8 100 50 10 500
1/2  1/2 1 1-1/2 32.5 100 50 10 500
3/4  3/4 2 3 52 100 50 10 500
1  1-1/2 3 5 81.9 100 50 10 500
2 3 5 7-1/2 130 100 50 10 500
3 3 7-1/2 10 169 100 50 10 500
3 5 10 10 208 100 50 10 500
5 5 10 15 260 100 50 10 500
7-1/2 7-1/2 15 20 325 100 50 10 500
10 10 20 30 416 100 50 10 500
200-
208VAC
220-
240VAC
440-
480VAC
550-
600VAC
Adjustable current range
Code
*1
Ie: Min.–Max.
(A)
P16 0.1–0.16
P25 0.16–0.25
P40 0.25–0.4
P63 0.4–0.63
001 0.63–1
1P6 1–1.6
2P5 1.6–2.5
004 2.5–4
6P3 4–6.3
010 6.3–10
013 9–13
016 11–16
020 14–20
025 19–25
032 24–32
Notes: *1 Replace the mark in the part number by current range codes.
*2 The BM3RHB is cUL listed as HP rated motor controllers.
*3 The BM3RHB is cUL listed for group Installation as per NEC430-53(C).
63A Frame types and ratings
Available Not available
Standard breaking capacity
Adjustable thermal-magnetic trip type BM3VSB-
AF01-47
Number of poles 3
Handle type
Rated current Ie (A)
Rated operational voltage Ue (V)
Rated frequency (Hz)
Rated insulation voltage Ui (V)
Rated impulse withstand voltage Uimp (kV)
Utilization IEC 60947-2 Circuit breaker
category IEC 60947-4-1 Motor starter
Trip class IEC 60947-4-1
Instantaneous trip characteristic
Power loss (total of 3-pole)
Mechanical durability (operations)
Electrical durability (operations)
Max. operations per hour (motor start-up)
Phase-loss protection
Trip indicator
Test trip function
UL/CSA 3phase HP rating (HP) *2Instantaneous UL/CSA Short circuit
Maximum listed branch
trip current (A) current rating (kA) *3circuit protection *3
240VAC 480VAC 600VAC Fuse or MCCB (A)
Dimensions (mm) W X H X D 55 X 110 X 96
Mass (g) 780
Optional Auxiliary contact block
accessory Alarm contact block
Auxiliary and alarm contact block
Short-circuit alarm contact block
Shunt trip device
Undervoltage trip device
External operating handle
Standard IEC 60947-1, 60947-2, 60947-4-1, UL 508, CSA C22.2 No.14
Rotary
10 to 63
200 to 690
50/60
1000
8
Cat. A
AC-3
10
13 x le max.
11W: In=10 to 32A 15W: In=40 to 50A 17W: In=63A
50,000
25,000
25
Provided
Provided
Provided
2 3 5 7-1/2 130 100 22 10 600
3 3 7-1/2 10 169 100 22 10 600
3 5 10 10 208 100 22 10 600
5 5 10 15 260 100 22 10 600
7-1/2 7-1/2 15 20 325 100 22 10 600
10 10 20 30 416 100 22 10 600
10 10 30 30 520 100 22 10 600
15 15 30 40 650 100 22 10 600
20 20 40 60 819 100 22 10 600
200-
208VAC
220-
240VAC
440-
480VAC
550-
600VAC
11
Manual Motor Starters
Quick reference guide
Code
*1
Ie: Min.–Max.
(A)
010 6.3–10
013 9–13
016 11–16
020 14–20
025 19-25
032
040
050
063
24-32
28-40
35-50
45-63
Adjustable current range
Notes: *1 Replace the mark in the part number by current range codes.
*2 The BM3VSB is cUL listed as HP rated motor controllers.
*3 The BM3VSB is cUL listed for group Installation as per NEC430-53(C).
63A Frame types and ratings
Available Not available
High breaking capacity
Adjustable thermal-magnetic trip type BM3VHB-
AF01-43
Number of poles 3
Handle type
Rated current Ie (A)
Rated operational voltage Ue (V)
Rated frequency (Hz)
Rated insulation voltage Ui (V)
Rated impulse withstand voltage Uimp (kV)
Utilization IEC 60947-2 Circuit breaker
category IEC 60947-4-1 Motor starter
Trip class IEC 60947-4-1
Instantaneous trip characteristic
Power loss (total of 3-pole)
Mechanical durability (operations)
Electrical durability (operations)
Max. operations per hour (motor start-up)
Phase-loss protection
Trip indicator
Test trip function
Adjustable current range
UL/CSA 3phase HP rating (HP) *2Instantaneous UL/CSA Short circuit
Maximum listed branch
trip current (A) current rating (kA) *3circuit protection *3
Code
*1
Ie: Min.–Max.
(A)
240VAC 480VAC 600VAC Fuse or MCCB (A)
010 6.3–10
013 9–13
016 11–16
020 14–20
025 19-25
032
040
050
063
24-32
28-40
35-50
45-63
Dimensions (mm) W X H X D 55 X 110 X 96
Mass (g) 780
Optional Auxiliary contact block
accessory Alarm contact block
Auxiliary and alarm contact block
Short-circuit alarm contact block
Shunt trip device
Undervoltage trip device
External operating handle
Standard IEC 60947-1, 60947-2, 60947-4-1, UL 508, CSA C22.2 No.14
Rotary
10 to 63
200 to 690
50/60
1000
8
Cat. A
AC-3
10
13 x le max.
11W: In=10 to 32A 15W: In=40 to 50A 17W: In=63A
50,000
25,000
25
Provided
Provided
Provided
2 3 5 7-1/2 130 100 50 10 600
3 3 7-1/2 10 169 100 50 10 600
3 5 10 10 208 100 50 10 600
5 5 10 15 260 100 50 10 600
7-1/2 7-1/2 15 20 325 100 50 10 600
10 10 20 30 416 100 50 10 600
10 10 30 30 520 100 50 10 600
15 15 30 40 650 100 50 10 600
20 20 40 60 819 100 50 10 600
200-
208VAC
220-
240VAC
440-
480VAC
550-
600VAC
12
Manual Motor Starters
Quick reference guide
Adjustable current range
Notes: *1 Replace the mark in the part number by current range codes.
*2 The BM3VHB is cUL listed as HP rated motor controllers.
*3 The BM3VHB is cUL listed for group Installation as per NEC430-53(C).
13
Manual Motor Starters
Manual motor starters
Code Ie; Min-Max.
(A)
P16
P25
P40
P63
001
1P6
2P5
004
6P3
010
013
016
020
025
032
0.1-0.16
0.16-0.25
0.25-0.4
0.4-0.63
0.63-1.0
1-1.6
1.6-2.5
2.5-4
4-6.3
6.3-10
9-13
11-16
14-20
19-25
24-32a
Rated capacity (HP)
220-240V AC
1/2
3/4
1-1/2
3
3
5
5
7-1/2
10
Rated capacity (HP)
440-480V AC
3/4
1
2
3
5
7-1/2
10
10
15
20
up to 240V AC
100
100
100
100
100
100
100
100
100
100
100
100
100
50
50
up to 480/277V AC
50
50
50
50
50
50
50
50
50
22
22
22
22
22
22
3 phase motor Short circuit rating(kA)
BM3RSB (Type E ratings)
To make an application for use with Type E controller, you need to prepare BZ0TCRE and BZ0TKUAB accessories for BM3RSB separately.
Type E ratings
In accordance with Motor full load current
Manual motor starters
Code Ie; Min-Max.
(A)
P16
P25
P40
P63
001
1P6
2P5
004
6P3
010
013
016
020
025
032
0.1-0.16
0.16-0.25
0.25-0.4
0.4-0.63
0.63-1.0
1-1.6
1.6-2.5
2.5-4
4-6.3
6.3-10
9-13
11-16
14-20
19-25
24-32
Rated capacity (HP)
220-240V AC
1/2
3/4
1-1/2
3
3
5
5
7-1/2
10
Rated capacity (HP)
440-480V AC
3/4
1
2
3
5
7-1/2
10
10
15
20
up to 240V AC
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
up to 480/277V AC
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
3 phase motor Short circuit rating(kA)
BM3RHB (Type E ratings)
To make an application for use with Type E controller, you need to prepare BZ0TCRE and BZ0TKUAB accessories for BM3RHB separately.
In accordance with Motor full load current
Manual motor starters
Code Ie; Min-Max.
(A)
010
013
016
020
025
032
040
050
063
6.3-10
9-13
11-16
14-20
19-25
24-32
28-40
35-50
45-63
Rated capacity (HP)
220-240V AC
3
3
5
5
7-1/2
10
10
15
20
Rated capacity (HP)
440-480V AC
5
7-1/2
10
10
15
20
30
30
40
up to 240V AC
100
100
100
100
100
100
100
100
100
up to 480/277V AC
22
22
22
22
22
22
22
22
22
3 phase motor Short circuit rating(kA)
BM3VSB (Type E ratings)
To make an application for use with Type E controller, you need to prepare BZ0TKUAB accessories for BM3VSB separately.
Manual motor starters
Code Ie; Min-Max.
(A)
010
013
016
020
025
032
040
050
063
6.3-10
9-13
11-16
14-20
19-25
24-32
28-40
35-50
45-63
Rated capacity (HP)
220-240V AC
3
3
5
5
7-1/2
10
10
15
20
Rated capacity (HP)
440-480V AC
5
7-1/2
10
10
15
20
30
30
40
up to 240V AC
100
100
100
100
100
100
100
100
100
up to 480/277V AC
50
50
50
50
50
50
50
50
50
3 phase motor Short circuit rating(kA)
BM3VHB (Type E ratings)
To make an application for use with Type E controller, you need to prepare BZ0TKUAB accessories for BM3VHB separately.
BM3 V H B - 063
Product category
Frame size
R: 32A Frame 45mm wide
V: 63A Frame 55mm wide
Rated current code (see page 9 to 12)
Operating characteristic
B: Adjustable thermal-magnetic trip
Breaking capacity
S: Standard breaking capacity
H: High breaking capacity
Ordering information
Specify the following:
1. Part number
2. Accessories if required
Manual Motor Starters
BM3RSB, RHB BM3VSB, VHB
Characteristic curves
110 100
Multiple of rated current (A)
Operating time (s)
0.001
0.01
0.1
1
10
100
1000
10000
3-phase cold start
3-phase hot start
Instantaneous trip
1100 to 1560% of
max. setting current
110 100
Multiple of rated current (A)
Operating time (s)
0.001
0.01
0.1
1
10
100
1000
10000
3-phase cold start
3-phase hot start
Instantaneous trip
1100 to 1560% of
max. setting current
Ordering information and Characteristics
14
Manual Motor Starters
Description Starter Mounting Contact Part number Mass
type arrangement (g)
BM3R Front 1NO BZ0WIA 9
BM3V 1NC BZ0WIB
Left side 2NO BZ0WUAAL 45
1NO+1NC BZ0WUABL
2NC BZ0WUBBL
Right side
2NO BZ0WUAAR 45
1NO+1NC BZ0WUABR
2NC BZ0WUBBR
Features
All accessories can be used with BM3R (45mm wide) and
BM3V (55mm wide) frames.
Accessories are easily mounted.
Internal auxiliary contact blocks and alarm contact blocks
can be mounted on front side.
External auxiliary contact blocks can be mounted on either
the right or left side.
These blocks are linked to the ON/OFF operation of
the MMS. Up to two contact blocks can be mounted
to the right/left front, and up to two contact blocks can
be mounted to the right/left sides.
Shunt trip and undervoltage trip devices are available in a
wide range of operating voltages.
Standard and emergency external handles are available.
IP20 terminal cover prevents accidental contact to
electrically charged parts.
Part number and ratings
Auxiliary contact blocks (W)
AF01-60L
AF01-59, 01-58
Description Starter Mounting Contact Part number Mass
type arrangement (g)
BM3R Front 1NO BZ0KIA 9
BM3V 1NC BZ0KIB
AF01-60R
Alarm contact blocks (K)
This block operates when the MMS trips due to
overload, phase-loss, or short-circuit. It is not linked
to the ON/OFF operation of the MMS.
Note: Operation can be checked with the test trip function.
(Right
side only)
Aux. contact block Alarm contact block
AF01-76
Aux. contact blocks
Aux. and alarm contact block
Short-circuit alarm contact block
Aux. contact blocks
Shunt-trip device
Undervoltage trip device
Optional accessories
15
16
Manual Motor Starters
Description Starter Mounting Contact Part number Mass
type arrangement (g)
BM3R Left 1NO (Aux.)+ BZ0WKUAA 45
BM3V 1NO (Alarm)
1NC (Aux.)+ BZ0WKUBA
1NO (Alarm)
1NO (Aux.)+ BZ0WKUAB
1NC (Alarm)
1NC (Aux.)+ BZ0WKUBB
1NC (Alarm)
• This contact block combines auxiliary contact and alarm
contact that operate in the event of an overload, phase loss,
or short-circuit. Alarm contact is not linked to the ON/OFF
operation of the MMS.
An alarm is displayed in the contact block’s indicator when
the alarm contact operates.
Note: Operation can be checked with the test trip function.
Auxiliary and alarm contact blocks (WK)
AF01-57
Description Starter Mounting Contact Part number Mass
type arrangement (g)
BM3R Left 1NO+1NC BZ0TKUAB 45
BM3V
The contacts operate only when the MMS has tripped due to
a short-circuit.
When these contacts operate, the blue reset button extends
out, and a trip indication is displayed.
The power to the MMS can be turned ON after pressing the
reset button.
Note: Operation can be checked with the test trip function.
Be sure to press the reset button before mounting to the MMS.
Short-circuit alarm contact block (KI)
AF01-56
Description Starter Mounting Coil voltage Part number Mass
type (g)
BM3R Right 24VAC 50/60Hz BZ0FAZU 115
BM3V 48VAC 60Hz BZ0FBZU
48VAC 50Hz/60VAC 60Hz BZ0FCZU
100VAC 50Hz/100–110VAC 60Hz BZ0F1ZU
110–127VAC 50Hz/120VAC 60Hz BZ0FDZU
200VAC 50Hz/200–220VAC 60Hz BZ0FEZU
220–230VAC 50Hz/240–260VAC 60Hz BZ0FFZU
240VAC 50Hz/277VAC 60Hz BZ0FGZU
380–400VAC 50Hz/400–440VAC 60Hz BZ0FHZU
415–440VAC 50Hz/460–480VAC 60Hz BZ0F4ZU
500VAC 50Hz/600VAC 60Hz BZ0FJZU
24–60V DC * BZ0FKZUD
110-240V DC * BZ0FLZUD
AF01-55
Shunt trip devices (F)
This device is used to remotely trip the MMS.
Notes:
This device cannot be used together with an
undervoltage trip device.
When the MMS has been tripped with the shunt
trip device, press the reset button before turning
ON the power.
Note: * The time rating of coil is 5s.
Description Starter Mounting Coil voltage Part number Mass
type (g)
BM3R Right 24VAC 50Hz BZ0RAZ1U 115
BM3V 24VAC 60Hz BZ0RAZ2U
48VAC 50Hz BZ0RBZ1U
48VAC 60Hz BZ0RBZU
100VAC 50Hz/100–110VAC 60Hz BZ0R1ZU
110–127VAC 50Hz/120VAC 60Hz BZ0RDZU
200VAC 50Hz/200–220VAC 60Hz BZ0REZU
220–230VAC 50Hz/240–260VAC 60Hz BZ0RFZU
240VAC 50Hz/277VAC 60Hz BZ0RGZU
380–400VAC 50Hz/400–440VAC 60Hz BZ0RHZU
415–440VAC 50Hz/460–480VAC 60Hz BZ0R4ZU
500VAC 50Hz/600VAC 60Hz BZ0RJZU
R types
This device automatically trips the MMS
when the control circuit voltage drops below
the specified value.
Notes:
This device cannot be used together with a shunt
trip device.
When the MMS has been tripped with the
undervoltage trip device, press the reset button
before turning ON the power.
AF01-54
Undervoltage trip devices (R)
Optional accessories
17
Manual Motor Starters
Description Starter Part number Mass
type (g)
BM3R BZ0SET 2.0
BM3V BZ0TCV 0.6
Others
Push-in lug
Terminal cover for IP20 Prevents accidental contact to charged parts.
6 pcs/pack
Used for screw mounting.
10 pcs/pack
Description Starter Handle type Part number Mass
type (g)
BM3RH Standard BZ0VBBL 160
(black)
Emergency BZ0VYRL 160
(red/yellow)
BM3V Standard BZ0VBBM 160
(black)
Emergency BZ0VYRM 160
(red/yellow)
Used to operate an MMS installed inside a panel, from the
outside of the panel.
Equipped with an interlock mechanism that prevents someone
from mistakenly opening the panel door when the MMS is in the
ON state.
The shaft can be cut to match the distance between the MMS
and the panel door.
Door interlock function • OFF lock function
Can be locked OFF with up to three padlocks.
Note: Padlocks not included.
Release screw allows the door to be opened with the handle in
the ON position.
IP54 enclosure
External operating handles
KK02-306
KK02-305
Description Starter Part number Mass
type (g)
BM3R BZ0TCRE 30
Used for making Type E or Type F condition
Line side terminal cover
BM3R BZ0CFG 1.4
BM3V
Used to cover the open space if an internally
mounted accessory should become unnecessary.
Mounts
10 pcs/pack
to either the left-front or right-front position.
Dummy cover
KK02-39
Optional accessories
18
Manual Motor Starters
Accessory type
Part number
Auxiliary contact Auxiliary contact Alarm contact Aux. and alarm Short-circuit alarm
block/front block/side block contact block contact block
BZ0WI BZ0WU BZ0KI BZ0WKU BZ0TKUAB
Standard IEC 60947-5-1, UL 508
Rated operational current 48V
.
AC AC-15 5 6 5 6 6
(A) 125V AC 3 4 3 4 4
230V AC 1.5 41.5 4 4
400V AC 2.2 2.2 2.2
500V AC 1.5 1.5 1.5
690V AC 0.6 0.6 0.6
48V
.
DC DC-13 1.38 51.38 5 5
110V
.
DC 0.55 1.3 0.55 1.3 1.3
220V
.
DC 0.27 0.5 0.27 0.5 0.5
Contact rating code UL 508 B300 A600 B300 A600 A600
Q300 P300 Q300 P300 P300
Min. voltage and current 17V 5mA
Ratings of accessories
Accessory type Shunt trip device Undervoltage device
BZ0F BZ0R
Standard IEC 60947-1, UL 508
Rated insulation voltage IEC 60947 690
(V AC) UL 508 600
No. of ON-OFF operations 5000
Operating time (ms) 20
Power consumption Inrush (VA/W)
21/12
Sealed (VA/W) 8/1.2
Voltage range Tripping voltage (V) 0.7 to 1.1Ue 0.35 to 0.7Ue
Closing voltage (V) 0.85 to 1.1Ue
Time rating of coil (s) AC: Continuous AC: Continuous
DC: 5
Part number
Optional accessories
Note: Ue: Rated Voltage
19
Manual Motor Starters
Available accessory configuration
External
device
(Right)
External
device
(Left)
Internal device
MMS
W
W
W2
W2
(Left)
W2
(Right)
KW+W W+K
W2W
W2W W2K W2WW W2WK
W2 W2W
W2W W2K W2WW W2WK W2 W2W
W2W W2K W2WW W2WK
W2F
W2R
W2WF
W2WF W2KF W2WWF W2WKF
W2WR
W2WR W2KR W2WWR W2WKR
WKF WKWF
WKWF WKKF WKWWF WKWKF
WKR WKWR
WKWR WKKR WKWWR WKWKR
WK WKW
WKW WKK WKWW WKWK
KI KIW
KIW KIK KIWW KIWK
FWF
WF KF WF
WF KF
WWF WKF
RWR
WR KR WWR WKR
KIF KIWF KIKF KIWWF KIWKF
KIWF
KIR KIWR KIKR KIWWR KIWKR
KIWR
W2W2 W2W2W W2W2K W2W2WW W2W2WK
W2W2W
W2W2 W2W2W W2W2K W2W2WW W2W2WK
W2W2W
W
W
W2
KW+W W+K
W2W
W2W W2K W2WW W2WK
W2F
W2R
W2WF
W2WF W2KF W2WWF W2WKF
W2WR
W2WR W2KR W2WWR W2WKR
WKF WKWF
WKWF WKKF WKWWF WKWKF
WKR WKWR
WKWR WKKR WKWWR WKWKR
WK WKW
WKW WKK WKWW WKWK
KI KIW
KIW KIK KIWW KIWK
FWWF WKF
RWR
WR KR WWR WKR
KIF KIWF KIKF KIWWF KIWKF
KIWF
KIR KIWR KIKR KIWWR KIWKR
KIWR
W2W2 W2W2W W2W2K W2W2WW W2W2WK
W2W2W
W2W2 W2W2W W2W2K W2W2WW W2W2WK
W2W2W
Adj. thermal-magnetic trip type MMS
Internal accessory
External accessory
BM3RSB, BM3RHB BM3VSB, BM3VHB
WK
(Left)
KI
(Left)
F
(Right)
R
(Right)
W2 (Left)+F
W2 (Left)+R
WK+F
WK+R
KI+F
KI+R
W2 (Left)+
W2 (Left)
W2 (Left)+
W2 (Right)
Shunt trip device (F) Undervoltage trip device (R)
Internal devices
Auxiliary contact block (W) Alarm contact block (K)
External devices
Auxiliary contact (W2) Short-circuit alarm contact block (KI)
Auxiliary and alarm contact block (WK)
Optional accessories
20
Manual Motor Starters
Available accessory configuration (continued)
Internal accessory
External accessory
Adj. thermal-magnetic trip type MMS
Shunt trip device (F) Undervoltage trip device (R)
Internal devices
Auxiliary contact block (W) Alarm contact block (K)
External devices
Auxiliary contact (W2) Short-circuit alarm contact block (KI)
Auxiliary and alarm contact block (WK)
W
WKW+W W+K W
WKW+W W+K
W2W2
W2 (Right)+
W2 (Right)
W2 (Left)+
WK
W2W2W
W2W2W W2W2K W2W2WW W2W2WK
W2W2F
W2W2R
W2W2WF
W2W2WF W2W2KF W2W2WWF W2W2WKF
W2W2WR
W2W2WR W2W2KR W2W2WWR W2W2WKR
W2WKF W2WKWF
W2WKWF W2WKKF W2WKWWF W2WKWKF
W2WKR W2WKWR
W2WKWR W2WKKR W2WKWWR W2WKWKR
W2WK W2WKW
W2WKW W2WKK W2WKWW W2WKWK
W2WK W2WKW
W2WKW W2WKK W2WKWW W2WKWK
W2KI
W2KIW
W2KIW W2KIK W2KIWW W2KIWK
W2KIW
W2KIW W2KIK W2KIWW W2KIWK
W2KI
KIWK KIWKW
KIWKW KIWKK KIWKWW KIWKWK
W2KIF W2KIWF W2KIKF W2KIWWF W2KIWKF
W2KIWF
W2KIR W2KIWR W2KIKR W2KIWWR W2KIWKR
W2KIWR
KIWKF KIWKWF KIWKKF KIWKWWF KIWKWKF
KIWKWF
KIWKR KIWKWR KIWKKR KIWKWWR KIWKWKR
KIWKWR
W2W2 W2W2W
W2W2W W2W2K W2W2WW W2W2WK
W2W2F
W2W2R
W2W2WF
W2W2WF W2W2KF W2W2WWF W2W2WKF
W2W2WR
W2W2WR W2W2KR W2W2WWR W2W2WKR
W2WKF W2WKWF
W2WKWF W2WKKF W2WKWWF W2WKWKF
W2WKR W2WKWR
W2WKWR W2WKKR W2WKWWR W2WKWKR
W2WK W2WKW
W2WKW W2WKK W2WKWW W2WKWK
W2WK W2WKW
W2WKW W2WKK W2WKWW W2WKWK
W2KI
W2KIW
W2KIW W2KIK W2KIWW W2KIWK
W2KIW
W2KIW W2KIK W2KIWW W2KIWK
W2KI
KIWK KIWKW
KIWKW KIWKK KIWKWW KIWKWK
W2KIF W2KIWF W2KIKF W2KIWWF W2KIWKF
W2KIWF
W2KIR W2KIWR W2KIKR W2KIWWR W2KIWKR
W2KIWR
KIWKF KIWKWF KIWKKF KIWKWWF KIWKWKF
KIWKWF
KIWKR KIWKWR KIWKKR KIWKWWR KIWKWKR
KIWKWR
BM3RSB, BM3RHB BM3VSB, BM3VHB
W2 (Right)+
WK
W2 (Left)+
KI
W2 (Right)+
KI
KI+WK
W2 (Left)+
W2 (Left)+F
W2 (Left)+
W2 (Left)+R
W2 (Left)+
WK+F
W2 (Left)+
WK+R
W2 (Left)+
KI+F
W2 (Left)+
KI+R
KI+WK+F
KI+WK+R
External
device
(Right)
External
device
(Left)
Internal device
MMS
Optional accessories
21
Auxiliary contact blocks, side mounting
BZ0WU
18.7
M3.5
70.4
53.6
47.2
90
45
66
48.7
35.7
2.8
2.3
9
Auxiliary and alarm contact blocks
BZ0WKU
35.7
18.7
M3.5
70.4
53.6
45
47.2
90
66
48.7
Indication
window
2.8
9
2.3
Dimensions, mm
Rotary handle types BM3RHB
91
ø5
27
27
45
75.3 3.7
45
14.3 14.3
M4
5.5
90
75
45
3.3
95
14.3
105
For mounting
screw
35mm top hat rail
Hight 15mm
Rocker handle types BM3RSB
45
14.3
13
5.5
14.3
ø5
90
75
45
13.5
6
95
105
14.3
M4
35mm DIN rail
Hight 15mm
45
27
27
71
62.3 3.7
27
For mounting
screw
Rotary handle types BM3VSB, BM3VHB
92.3
107.8
88.3
4.281.3
55
16.5
110
84
3.3
45
4.5
5
66
120
16.5
M6
ø5
5.5
42
33.8
33.8
35mm DIN rail
Hight 15mm
Accessories
Auxiliary contact blocks, front mounting
BZ0WI
M3.5
9
21.5 10.5
16.7
38.8
8.518.9
Alarm contact blocks, front mounting
BZ0KI
M3.5
9
21.5 10.5
8.518.9
1
16.7
38.8
Manual Motor Starters
Dimensions
22
Accessories
Short-circuit alarm contact block
BZ0TKUAB
35.7
66
48.7
18.7
M3.5
Reset button
2.8
96
70.4
53.6
47.2
90
45
2.3
MMS with accessories
BM3RSB + BZ0 BZ0TCRE
Type E construction
BM3RSB BM3RHB
81
90
45
95
10.5
45 18 71
45
62.3 3.7
99
BM3RHB + BZ0
81
45 18
91
62.3
45
75.3 3.7
9
90
45
95
10.5
9
Shunt trip devices BZ0F
Undervoltage trip devices BZ0R
2.3
70.4
47.2
45
90
M3.5
66
48.7
18.7 5.2
18
2.8
BM3V B + BZ0
91
55 1818
43
99
110
45
90
120
92.3
107.8 4.2
79.3
62
13.3
Manual Motor Starters
Dimensions
Dimensions, mm
MMS
BM3RSB
Line side terminal cover
BZ0TCRE
Short-circuit alarm
contact block
BZ0TKUAB
Mass (g)
425
MMS
BM3RHB
Line side terminal cover
BZ0TCRE
Short-circuit alarm
contact block
BZ0TKUAB
Mass (g)
445
47.3
45
68.3
53
15
3.7
62.3
71
13
ø
5
For mounting screw
45
95
9
49.3
58.3
5.5
27
47.5
13.5
45
6
47.3
91
75.3
45
68.3
53
3.7
62.3
15
ø
5
For mounting screw
45
5.5
3.3
95
49.3
58.3
47.5
45
9
10.8
35.5
8
10.5
5.4 13
55.5
45
L1
1L2
35L3
3-ø7.5
23
Type X min. X max.
BZ0VBBL, BZ0VYRL 139 ±2 289 ±2
BZ0VBBM, BZ0VYRM 156 ±2 306 ±2
Panel
66
66
3.3
5.5
45
Mounting screw
Shaft
Top of handle
Panel thickness 1.5 to 5
X
of handle
C
L
of MMS
C
L
of
MMS
C
L
of
handle
C
L
Min. 75
Door hinge
Max. 68
Type
BM3RH
BM3V
A
48.5
58.5
4-ø3.5
ø5
ø28
C
L
C
L
52.6
52.6
Locked
of
handle
C
L
of
handle
C
L
A
External operation handle BZ0V
Panel drilling
Manual Motor Starters
Dimensions
Dimensions, mm
85.3
79.3
62
15
13.3
107.8
92.3
88.3
81.3
78.6
4.2
110
66
45
120
47.3
90
3.3
5.5
955
Type E construction
BM3VSB, BM3VHB
MMS
BM3VSB,VHB
Line side terminal cover
-
Short-circuit alarm
contact block
BZ0TKUAB
Mass (g)
825
24
Wiring diagrams
• MMS
L1
1
L2
3
L3
T1 T2 T3
5
2 4 6
• Auxiliary contact blocks
Front mounting
BZ0WIA BZ0WIB
11(21)
12(22)
13(23)
14(24)
• Alarm contact blocks
Front mounting
BZ0KIBBZ0KIA
25
26
27
28
Undervoltage trip devices
BZ0R
D1
D2
U<
• Short-circuit alarm contact blocks
BZ0TKUAB
85
87
88
86
• Shunt trip devices
BZ0F C1
C2
53(153)
63(163)
54(154)
64(164)
BZ0WUAAL BZ0WUABL BZ0WUBBL
BZ0WUAAR BZ0WUABR BZ0WUBBR
43(143)
33(133)
34(134)
44(144)
43(143)
31(131)
32(132)
44(144)
41(141)
32(132)
42(142)
31(131)
51(151)
63(163)
52(152)
64(164)
51(151)
61(161)
52(152)
62(162)
Side mounting • Auxiliary and alarm contact blocks
BZ0WKUAB
75
73
74
76
BZ0WKUBB
75
71
72
76
BZ0WKUBA
77
71
72
78
BZ0WKUAA
77
73
74
78
Manual Motor Starters
Dimensions
25
Standard operating conditions
Ambient Operating: –5 to +55 C
temperature Storage: –40 to +65 C
Humidity 45 to 85%RH
Altitude 2000m or lower
Atmosphere No excessive dust, smoke, corrosive gases, flammable
gases, steam or salt.
Vibration 10 to 55Hz 15m/s2
Shock 50m/s2
Type Rated operational Min. distance to grounded
voltage Ue metal (mm)
(V) A, B C, D
BM3RS Up to 460 15 20
500 15 30
Up to 690 40 40
BM3RH Up to 500 15 30
Up to 690 40 50
BM3V Up to 500 15 40
Up to 690 40 50
Mountings
Rail mounting
The MMS can be mounted to a 35mm DIN rail. Secure the
rail with screws at mounting pitch of less than 400mm for the
BM3R type and less than 300mm for the BM3V type.
Applicable rail:
Use a 15mm-high TH35-15 (FUJI model TH35-15AL) rail
conforming to EN-50022 and IEC715.
The standard rail mounting direction is horizontal. When using
the MMS on a vertically mounted rail, use FUJI end clamp kits.
Mounting Removing
15mm
35mm wide rail
Snap
1
1
2
ø5mm or less
Screw mounting
The separately sold push-in lug (BZ0SET) is required for
screw mounting the BM3R frame. The BM3V frame can be
screw mounted directly to the panel.
BM3RSB BM3VSB
BM3RHB BM3VHB
M4
M4
M4
M4
Push-in lug
BZ0SET
Mounting angle
180 180
30
90
When frames are mounted side-by-
side, operating conditions such as a
high ambient temperature or using
the maximum setting for continuous
current may cause slight changes in
operating characteristics due to
temperature rises.
Under such conditions, it is
recommended that the frames be
separated by at least 5mm.
Type BM3R BM3V BZ0
Accessories
Solid wire (mm) ø1.6 to 2.6 ø1.6 to 2.6 ø1 to 1.6
Stranded Single-wire 1 to 10 1 to 25 0.5 to 2.5
wire (mm2)2-wire 1 to 6 1 to 16 0.5 to 2.5
AWG Single-wire 18 to 8 18 to 4 18 to 14
2-wire 18 to 10 18 to 4 18 to 14
Sheath stripping Approx.10 Approx.13 Approx.10
length (mm)
Terminal screw Pan head Pan head Pan head
screw (PZ2) screw (PZ2) screw (PZ2)
M4 M6 M3.5
Tightening torque 2 4 0.8
(N·m)
Arc space
The arc space required when mounting is shown in the table
below.
Wirings
While pressing the wire with a screwdriver, tighten the screw
to the specified tightening torque.
No sudden temperature
changes resulting in
condensation or icing.
No abnormal shock or
vibration
Note: There is no need for a crimp terminal or any other terminal on the end of
the connection wire.
C
A
D
B
Grounded metal
Manual Motor Starters
Instructions
26
Description Used with Specification Part number Mass (g)
Busbar BM3R Continuous current: 2-BM3R, modular space: 45mm BZ0BR02A 30
64A max. 3-BM3R, modular space: 45mm BZ0BR03A 50
Pin connection 4-BM3R, modular space: 45mm BZ0BR04A 70
5-BM3R, modular space: 45mm BZ0BR05A 90
BM3R+1-external 2-BM3R, modular space: 54mm BZ0BR12A 30
accessory, 9mm wide 3-BM3R, modular space: 54mm BZ0BR13A 55
4-BM3R, modular space: 54mm BZ0BR14A 80
5-BM3R, modular space: 54mm BZ0BR15A 105
BM3R+2-external Continuous current: 2-BM3R, modular space: 63mm BZ0BR22A 45
accessory, 9mm wide 64A max. 4-BM3R, modular space: 63mm BZ0BR24A 100
or Fork connection
BM3R+1-external
accessory, 18mm wide
BM3V Continuous current: 2-BM3V, modular space: 55mm BZ0BV02A 140
126A max. 3-BM3V, modular space: 55mm BZ0BV03A 240
Pin connection 4-BM3V, modular space: 55mm BZ0BV04A 340
BM3V+1-external 2-BM3V, modular space: 64mm BZ0BV12A 150
accessory, 9mm wide 3-BM3V, modular space: 64mm BZ0BV13A 270
4-BM3V, modular space: 64mm BZ0BV14A 380
BM3V+2-external 2-BM3V, modular space: 73mm BZ0BV22A 165
accessory, 9mm wide 4-BM3V, modular space: 73mm BZ0BV24A 425
or
BM3V+1-external
accessory, 18mm wide
3-phase feed-in terminal BM3R Continuous current: 64A max. BZ0BFRA 40
Applicable cable size: 25mm2 max.
BM3V Continuous current: 126A max. BZ0BFVA 170
Applicable cable size: 50mm2 max.
BZ0BR For pin connection BZ0BCRA 10
For fork connection BZ0BCRB 5
BZ0BV For pin connection BZ0BCVA 5
Features
The busbar system reduces wiring time and saves
floorspace.
The busbar makes it easy to power from 2 to 5 manual motor
starters – with no wiring needed.
The 3-phase feed-in terminals are used to connect the wire
for the power supply circuit.
The busbar cover guards against accidental contact with non-
connected busbar terminals (charged parts).
<Note>
If using BZ0TCRE terminal cover with BM3R series MMS, the busbar
system can not be used.
Busbar cover
Busbar
3-phase feed-in
terminals
Manual motor
starter
Connecting
module
Contactor
Reverse connection kit
KK02-159
Part number and ratings
AF01-70R
AF01-70L
KK02-164
Busbar cover
Manual Motor Starters
Busbar system
27
Dimensions, mm
For BM3R
BZ0BR0 Without external accessory
80
125
170
215
12
2
12.5
13
27.5
2 4
45
1414
13.5
BZ0BR02A: 80mm
BZ0BR03A: 125mm
BZ0BR04A: 170mm
BZ0BR05A: 215mm
BZ0BR1 With 1-external accessory
12
13
2
12.5
14 14
54
27.5
13.5
197
143
89
2 4
251
BZ0BR12A: 89mm
BZ0BR13A: 143mm
BZ0BR14A: 197mm
BZ0BR15A: 251mm
BZ0BR2 With 2-external accessory, 9mm wide
With 1-external accessory, 18mm wide
14 14
4.5
2
18
63
235
109
19
32.5
1.5
11
BZ0BR22A: 109mm
BZ0BR24A: 235mm
For BM3V
BZ0BV0 Without external accessory
17 17
42.5
205
23
97
151
16 20
24
30
33
5
55
BZ0BV02A: 97mm
BZ0BV03A: 151mm
BZ0BV04A: 205mm
BZ0BV1 With 1-external accessory, 9mm wide
4
16
17 17
2.5
64
23
232
106
169
20
24
30
33
5
BZ0BV12A: 106mm
BZ0BV13A: 169mm
BZ0BV14A: 232mm
BZ0BV2 With 2-external accessory, 9mm wide
With 1-external accessory, 18mm wide
4
23
260
73
16
17 17
2.5
20
24
30
33
5
116
BZ0BV22A: 116mm
BZ0BV24A: 260mm
Manual Motor Starters
Busbar system
28
BZ0BFVA
(10-4 AWG)
29
17
717 17 6
17 17
54
48.5
4
M4
10-50mm
2
2
Hexagon socket head bolt
54
Dimensions, mm
3-phase feed-in terminals
BZ0BFRA
27
24
38.5
1.5
14.514.5
314.5 14.5 3.8
1.9
25
13.5 5
6.5
M4
44.5
6-25mm2
(10-4 AWG)
Manual Motor Starters
Busbar system
29
Features
Accommodates a variety of manual motor starters
(BM3RSB-P16 to 025). Put the manual motor starter inside
an enclosure for use in harsh environments. Surface
mounting and flush mounting types available.
IP41 and IP55 enclosure protection degree available.
Manual motor starters (BM3RSB-P16 to 025) equipped with
internal accessories and the following external accessories
can be used inside an enclosure.
Left side: One auxiliary contact block (W) or one auxiliary
and alarm contact block (WK)
Right side:
A wide variety of enclosure accessories are available.
Padlocking device, emergency mushroom head pushbutton,
conversion kit, and indicator lamps.
One shunt trip device (F) or one undervoltage trip
device (R)
Part number and ratings
Enclosures for BM3RSB-P16 to 025
Mounting Specification
Part number
Mass (g)
Surface IP41 BZ0CSLA 320
IP55 (with conversion kit) BZ0CSLB 340
Flush IP41 BZ0CFLA 240
IP55 (with conversion kit) BZ0CFLB 260
Accessories for enclosures
Description Specification Part number Mass (g)
Padlocking device OFF locking possible using up to three padlocks with a 5 to 8mm shackle diameter. BZ0CKA 90
Emergency pushbutton Momentary BZ0CPM 55
Push-lock turn reset BZ0CPL 55
Key operated BZ0CPK 90
Conversion kit Converts IP41 to IP55 BZ0CCA 25
Adaptor set For BM3RS + undervoltage trip device with auxiliary contact. BZ0CUA 20
Neutral connector Used inside the enclosure for neutral and ground connection. BZ0CNA 10
Indication lamp Green, 100–120V AC BZ0CLGA 15
Green, 200–240V AC BZ0CLGB 15
Green, 380–440V AC BZ0CLGC 15
Green, 480–500V AC BZ0CLGD 15
Green, 500–600V AC BZ0CLGE 15
Red, 100–120V AC BZ0CLRA 15
Red, 200–240V AC BZ0CLRB 15
Red, 380–440V AC BZ0CLRC 15
Red, 480–500V AC BZ0CLRD 15
Red, 500–600V AC BZ0CLRE 15
White, 100–120V AC BZ0CLCA 15
White, 200–240V AC BZ0CLCB 15
White, 380–440V AC BZ0CLCC 15
White, 480–500V AC BZ0CLCD 15
White, 500–600V AC BZ0CLCE 15
Surface mounting
enclosure
Flush mounting
enclosures
Padlocking device
Emergency pushbuttons
Adaptor set
Neutral connector Conversion kits
IP41 to IP55
Indication lamps
Notes: The padlocking device cannot be used together with the emergency pushbutton or undervoltage trip device with auxiliary contact.
The emergency pushbutton cannot be used together with the undervoltage trip device with auxiliary contact.
Manual Motor Starters
Enclosures
30
Dimensions, mm
Surface mounting
For without accessory
ø4.5
ø4.5
145
20.4
45
1.5 150 2.2
ø2
1
98
69 28 1.6
18.8
85
155
7.852
For with padlocking device
17.8
ø8.5
150
155
167.5
11.5
Non locked OFF locked
Padlocks
with max. 8mm dia.
11.5
20.4
45
18.8
52
85
ø4.5
145
11.8
2.2
150
12.5
69 28
113
98
1.5
1
82
ø4.5
1.6
ø2
For with emergency pushbutton
Push-locked
20
20
39
19
Non locked
26
26
45
25
X dimensions
Momentary
Push-lock turn reset
With key
Without key
X
ø4.5
ø4.5
30 69
2.2
150
128
145
155
13.552
20.4
45
85
98 1.6
18.8
18
ø2
1.5
Flush mounting
For without accessory
82.5
125*
81.5*
15.6
115
96.5
139
Max. 6
Min. 1.5
18.8
7.852
82–84
R3 max.
126–128
Panel cutting
For with padlocking device
ø8.5
OFF lockedNon locked
23 162
82
125*
81.5*
30.5
15.6
82.5
115
12.5
139
7.852
96.5
18.8
Max. 6
Min. 1.5
11.5 11.5
Padlocks
with
max. 8mm
dia. 82–84
R3 max.
126–128
Panel cutting
For with emergency pushbutton
18 81.5*
40.1
18.8
15.6
30
X
13.552
139
115
125*
Max. 6
Min. 1.5
82.5
96.5
Push-locked
20
20
39
19
Non locked
26
26
45
25
X dimensions
Momentary
Push-lock turn reset
With key
Without key
82–84
R3 max.
126–128
Panel cutting
Manual Motor Starters
Dimensions
31
Contactors SC-M and SC-E series
3 to 100HP at 480V AC
The SC-M and SC-E series further enhance the high reliability of the SC series
with full conformance to International standards.
International standardization
IEC 60947-4-1, EN 60947-4-1, VDE 0660
UL
[Approved cUL (File No. E42419, E44592),
TÜV (R2018010, R2150072, R50013402)]
508, CSA C 22.2, JIS C 8201-4-1
Compactness
SC-M01, M02: 45mm wide
SC-E02 to E05: 43mm wide, SC-E1 to E2S: 54mm wide
SC-E3,
SC-E6: 100mm wide, SC-E7: 115mm wide
E4: 67mm wide, SC-E5: 88mm wide
Reducing mounting area
Safety
Terminals with finger-touch protection (DIN 57106/
VDE 0106 Teil100)
Utility
Box lug terminal construction
Long electrical life
Reduction of wiring work
Ecology
Reducing power consumption
Recycled thermoplastic resin used for plastic parts.
The names of materials are indicated on all major
parts to facilitate their recycling.
In addition to the five basic concepts of the existing SC series
magnetic contactors and motor starters — international
standardization, compactness, safety, utility, and ecology
the SC-M and SC-E series take the line-up to the next step in
utility with a new finger protection terminal and box lug
terminal construction.
48
56
45mm 54mm
96
90
67mm
111
112
100mm
138
169
SC-M series SC-E series
SC-M01, M02 SC-E1 to E2S SC-E3, E4 SC-E6 with SUPER
magnet
General information
I
n
t
e
r
n
a
t
i
o
n
a
l
s
t
a
n
d
a
r
d
i
z
a
t
i
o
n
F
i
n
g
e
r
p
r
o
t
e
c
t
i
o
n
t
e
r
m
i
n
a
l
B
o
x
l
u
g
t
e
r
m
i
n
a
l
c
o
n
s
t
r
u
c
t
i
on
Compactness
Compactness
Ecology
Ecology
Safety
Safety Utility
Utility
32
Contactors SC-M and SC-E series
R
Quick reference guide
R
Contactor SC-M01 SC-M02 SC-E02 SC-E03 SC-E04 SC-E05 SC-E1
SC-M01/G SC-M02/G SC-E02/G SC-E03/G SC-E04/G SC-E05/G SC-E1/G
KK02-292 KK02-292 AF01-12 AF01-11 AF01-10 KK01-105 AF01-8
Rating of 3-phase motor
AC operating
DC operating
(HP)
200V 1-1/2 3 2 3 5 5 7 1/2
1-1/2 3 2 3 5 7 1/2 10
3 5 5 7 1/2 10 15 25
3 5 5 7 1/2 10 15 25
220-240V
400-480V
550-600V
Rated operational current (A)
200V
220-240V
400-480V
550-600V
6.9 11 7.8 11 17.5 17.5 25.3
6 9.6 6.8 9.6 15.2 22 28
4.8 7.6 7.6 11 14 21 34
3.9 6.1 6.1 9 11 17 27
Rated thermal current AC-1 (A) 20 20 20 20 25 32 50
Auxiliary contact 1NO, 1NC 1NO, 1NC
Dimensions AC operated 45 48 56 43 80 81 54 90 96
W H D (mm) DC operated 45 48 68 43 80 108 54 90 121.5
Standard IEC 60947-1, EN 60947-4-1, VDE 0660, UL 508, CSA C22.2
Thermal overload relay TK-E02 TK-E02 TK-E02 TK-E02 TK-E2
KK01-86 KK01-86 KK01-86 KK01-86 KK01-88
Ampere setting range (A) 0.1–0.15 0.1–0.15 0.1–0.15 0.1–0.15 4–6
0.13–0.2 0.13–0.2 0.13–0.2 0.13–0.2 5–8
0.15–0.24 0.15–0.24 0.15–0.24 0.15–0.24 6–9
0.2–0.3 0.2–0.3 0.2–0.3 0.2–0.3 7–11
0.24–0.36 0.24–0.36 0.24–0.36 0.24–0.36 9–13
0.3–0.45 0.3–0.45 0.3–0.45 0.3–0.45 12–18
0.36–0.54 0.36–0.54 0.36–0.54 0.36–0.54 18–26
0.48–0.72 0.48–0.72 0.48–0.72 0.48–0.72 24–36
0.64–0.96 0.64–0.96 0.64–0.96 0.64–0.96
0.8–1.2 0.8–1.2 0.8–1.2 0.8–1.2
0.95–1.45 0.95–1.45 0.95–1.45 0.95–1.45
1.4–2.2 1.4–2.2 1.4–2.2 1.4–2.2
1.7–2.6 1.7–2.6 1.7–2.6 1.7–2.6
2.2–3.4 2.2–3.4 2.2–3.4 2.2–3.4
2.8–4.2 2.8–4.2 2.8–4.2 2.8–4.2
4–6 4–6 4–6 4–6
5–8 5–8 5–8 5–8
6–9 6–9 6–9 6–9
7–11 7–11 7–11 7–11
9–13 9–13 9–13
12–18 12–18
16–22
20–25
Dimensions W H D (mm) 53 60.5 80.5 54 78.5 97
Standard IEC 60947-1, EN 60947-4-1, VDE 0660, UL 508, CSA C22.2
33
Contactors SC-M and SC-E series
Contactors SC-E2 SC-E2S SC-E3 SC-E4 SC-E5 SC-E6 SC-E7
SC-E2/G SC-E2S/G SC-E3/G SC-E4/G
AF01-7 AF01-6 AF01-5 AF01-4 AF01-3 AF01-2 AF01-1
Rating of 3-phase motor (HP)
200V 10 15 20 25 30 40 50
15 20 25 30 30 40 50
30 30 50 50 60 75 100
30 30 50 50 75 100 125
Rated operational current (A)
200V
220-240V
220-240V
400-480V
400-480V
550-600V
550-600V
32.2 48.3 63.1 78.2 92 119.6 149.5
42 54 68 80 80 104 130
40 40 65 65 77 96 124
32 32 52 52 77 99 125
Rated thermal current AC-1 (A) 60 65 100 105 150 150 200
Auxiliary contact 2NO+2NC 2NO+2NC 2NO+2NC
Dimensions AC operated 54 90 96 67 112 111 88 155 132
100 169 138 115 175 140
W H D (mm) DC operated 54 90 121.5 67 112 130
Standard IEC 60947-1, EN 60947-4-1, VDE 0660, UL 508, CSA C22.2
Thermal overload relay TK-E2 TK-E2 TK-E3 TK-E3 TK-E5 TK-E6 TK-E6
KK01-88 KK01-88 KK01-87 KK01-87 KK01-85 KK01-84 KK01-84
Ampere setting range (A) 4–6 4–6 7–11 7–11 18–26 45–65 45–65
5–8 5–8 9–13 9–13 24–36 53–80 53–80
6–9 6–9 12–18 12–18 28–40 65–95 65–95
7–11 7–11 18–26 18–26 34–50 85–125 85–125
9–13 9–13 24–36 24–36 45–65 110–160
12–18 12–18 28–40 28–40 65–95
18–26 18–26 34–50 34–50 85–105
24–36 24–36 45–65 45–65
32–42 32–42 48–68 48–68
40–50 64–80
44–54
Dimensions W H D (mm) 54 78.5 97 68 89.5 107.5
76.5 105 106
100 122 123
Standard IEC 60947-1, EN 60947-4-1, VDE 0660, UL 508, CSA C22.2
R
Quick reference guide
R
AC operating
DC operating
34
Contactors SC-M and SC-E series
Code Coil operating voltage and frequency
24VAC 24V AC 50Hz / 24–26V AC 60Hz
48VAC 48V AC 50Hz / 48–52V AC 60Hz
100VAC 100V AC 50Hz / 100–110V AC 60Hz
110VAC 100–110V AC 50Hz / 110–120V AC 60Hz
120VAC 110–120V AC 50Hz / 120–130V AC 60Hz
200VAC 200V AC 50Hz / 200–220V AC 60Hz
220VAC 200–220V AC 50Hz / 220–240V AC 60Hz
400VAC 380–400V AC 50Hz / 400–440V AC 60Hz
440VAC 415–440V AC 50Hz / 440–480V AC 60Hz
500VAC 480–500V AC 50Hz / 500–550V AC 60Hz
Super Magnet Coil, SC-E5 to SC-E7
Code Coil operating voltage and frequency
24V 24–25V AC 50/60Hz, 24V DC
48V 48–50V AC 50/60Hz, 48V DC
100V 100–127V AC 50/60Hz, 100–120V DC
200V 200–250V AC 50/60Hz, 200–240V DC
400V 380–450V AC 50/60Hz
500V 460–575V AC 50/60Hz
Available coil
AC coil, SC-M01 to SC-M02 and SC-E02 to SC-E4
Code Coil operating voltage
12VDC 12V DC
24VDC 24V DC
48VDC 48V DC
100VDC 100V DC
110VDC 110V DC
200VDC 200V DC
DC coil, SC-M01/G to SC-M02/G and SC-E02/G to SC-E4/G
DC operation
Frame size Power consumption (VA) Power loss (W) Pick-up voltage (V) *1Drop-out voltage (V) *1Operating time (ms)
Inrush Sealed Coil ON Coil OFF
50/60 Hz 50/60 Hz 50Hz 60Hz Contact ON
Contact OFF
M01, M02 32/36 6/6 1.5 1.6 0.8–1.1 X US 0.35–0.55 X US 7–12 6–13
90/95 9/9 2.7 2.8 0.85–1.1 X US 0.2–0.75 X US 9–20 5–16
120/135 12.7/12.4 3.6 3.8 0.85–1.1 X US 0.2–0.75 X US 10–17 6–13
180/190 13.3/13.4 4.5 5 0.85–1.1 X US 0.2–0.75 X US 10–18 8–18
80/95 4/4.6 3.2 3.6 0.85–1.1 X US 0.2–0.75 X US 39–45 27–33
190/230 4.9/5.8 3.4 3.7 0.8–1.1 X US 0.1–0.65 X US 31–37 30–36
E02 to E05
E1 to E2S
E3, E4
E5
E6, E7
Coil characteristics
AC operation
Frame size Power consumption (VA) Time constant (ms) Pick-up voltage (V) *1Drop-out voltage (V) *1Operating time (ms)
Inrush Sealed Coil ON Coil OFF
Contact ON
Contact OFF
M01/G, M02/G 0.8–1.1 X US 0.2–0.4 X US 24–27 5–8
0.85–1.1 X US 0.1–0.75 X US 45–49 10–26
0.85–1.1 X US 0.1–0.75 X US 40–50 8–17
0.85–1.1 X US 0.1–0.75 X US 60–70 14–21
0.85–1.1 X US 0.1–0.75 X US 35–41 26–32
0.8–1.1 X US 0.1–0.65 X US 28–34 27–33
E02/G to E05/G
E1/G to E2S/G
E3/G, E4/G
E5
E6, E7
Quick reference guide
Note: *1 US: Rated coil voltage
Note: *1 US: Rated coil voltage
3
7
9
12
20
225
3
7
9
12
2.8
3.2
35
50
60
70
1
1
Frame size Rated insulation Rated thermal Making and breaking current (A)
voltage (V) current (A) AC (rating code A600) DC (rating code Q300)
Voltage Making Breaking Voltage Making Breaking
M01, M02
M01/G, M02/G
600 16
120V
240V
480V
600V
60
30
15
12
6
3
1.5
1.2
125V
250V
301-600V
0.55
0.27
0.1
0.55
0.27
0.1
E02 to E4, E02/G to E4/G
E5 to E7 600 10 120V
240V
480V
600V
60
30
15
12
6
3
1.5
1.2
125
250V
0.55
0.27
0.55
0.27
Auxiliary contact ratings for UL and CSA
35
Contactors SC-M and SC-E series
Ordering information and Characteristics
Ordering information
Specify the following :
1. Part number
2. Operating coil voltage code
3. Auxiliary contact arrangement (SC-M series only)
-SC-E 24VAC
Operating coil voltage code
(see page 34)
• AC-1 duty / 380 to 440 V AC / SC-M
10
100
20
30
50
1000
200
300
500
10000
2000
3000
5000
1 2 3 20 30 50 100 5 10
SC-M01
SC-M02
Breaking current (A)
Make / Break operations ( 10
3
)
• AC-3 duty / 380 to 440 V AC / SC-M
10
100
20
30
50
1000
200
300
500
10000
2000
3000
5000
1 2 3 20 30 50 100 5 6A 9A 10
SC-M01
SC-M02
Breaking current (A)
Make / Break operations ( 10
3
)
Electrical durability
-SC-M 01 24VAC - 1NO/G
Aux. contact arrangement
1NO or 1NC required
Operating coil voltage code
(see page 34)
Product
category
Product
category
Frame size
AC coil operating: None
DC coil operating: /G
/G
AC coil operating: None
DC coil operating: /G
-02
Frame size
36
Contactors SC-M and SC-E series
Electrical durability
• AC-3 duty / SC-E1 to SC-E7
10 20 30 200 300 500 1000 2000 3000 5000 10000
10050
10
100
20
30
50
1000
200
300
500
10000
2000
3000
5000
SC-E1
SC-E2
SC-E2S
32A
40A
50A
65A
80A
105A
150A
10
100
20
30
50
1000
200
300
500
10000
2000
3000
5000
200 - 240V 380 - 440V
125A
SC-E7
SC-E3
SC-E4
SC-E5
SC-E6
Breaking current (A)
Make/break operations ( 10
3
)
• AC-1 duty / SC-E02 to SC-E7
32A
20A
60A
100A
150A
50A
25A
65A
105A
200A
100
1000
200
300
500
10000
2000
3000
5000
100
1000
200
300
500
2000
3000
5000
200 - 240V
1 2 3
SC-E02
SC-E03
SC-E05
SC-E04
SC-E1
SC-E2
SC-E2S
380 - 440V
SC-E3
SC-E4
SC-E5
SC-E6
SC-E7
20 30 50 100 200 300 500 1000
105
10000
Breaking current (A)
Make/break operations ( 10
3
)
Ordering information and Characteristics
• AC-3 duty / SC-E02 to SC-E05
1 2 3 20 30 50 100 200 300 500 1000
105
10
100
20
30
50
1000
200
300
500
10000
2000
3000
5000
Breaking current (A)
SC-E02
SC-E05
SC-E04
SC-E03
9A
12A
18A
25A
10
100
20
30
50
1000
200
300
500
10000
2000
3000
5000
200 - 240V 380 - 440V
Make/break operations ( 10
3
)
37
• Auxliary contact blocks with terminal covers
Applicable contactor Mounting No. of contacts Contact arrangement Part number
SC-M01, M02
SC-M01/G, M02/G
Front mounting 4
2
1
4
2
2
2
4NO
3NO+1NC
2NO+2NC
1NO+3NC
4NC
2NO
1NO+1NC
2NC
1NO
1NC
4NO
3NO+1NC
2NO+2NC
2NO
1NO+1NC
2NC
1NO+1NC
1NO+1NC
SZ-MA40
SZ-MA31
SZ-MA22
SZ-MA13
SZ-MA04
SZ-MA20
SZ-MA11
SZ-MA02
SZ-MAS10
SZ-MAS01
SZ-A40/T
SZ-A31/T
SZ-A22/T
SZ-A20/T
SZ-A11/T
SZ-A02/T
SZ-AS1/T
SZ-AS2/T
SC-E02 to E4
SC-E02/G to E4/G
Side mounting
Front mounting
Side mounting
Side mounting
SC-E5, E6, E7
Main circuit surge suppression units
Applicable Mounting Rated voltage CR constant Applicable Part
number
contactor and frequency 3-phase motor
SC-E02 to E05
SC-E02/G to E05/G
SC-M01, M02,
M01/G, M02/G
Front mounting 250V AC
50/60Hz
C=0.22 F 200–240V
AC SZ-ZM1E
Side mounting R=100 1-1/2–5HP SZ-ZM2E
SC-E1 to E4
SC-E1/G to E4/G
Front mounting 250V AC
50/60Hz
C=0.33 F 200–240V AC SZ-ZM3E
Side mounting R=47 1-1/2–30HP SZ-ZM4E
Coil surge suppression units
Applicable
contactor
Operating Device Operation Part
number
coil voltage indicator
SC-M01, M02
SC-M01/G,M02/G
12–60VAC
72–250VAC
6–250V DC
24–48V AC/DC
100–250V AC/DC
380–440V AC/DC
24–48V AC/DC
100–250V AC/DC
24–48V AC/DC
100–250V AC/DC
380–440V AC/DC
24–48V AC/DC
100–250V AC/DC
24–48V AC/DC
100–250V AC/DC
24–48V AC/DC
100–250V AC/DC
24–48V AC/DC
100–250V AC/DC
CR
Diode
Varistor
SZ-MZ1
SZ-MZ2
SZ-MZ3
SZ-Z1
SZ-Z2
SZ-Z3
SZ-Z6
SZ-Z7
SZ-Z31
SZ-Z32
SZ-Z33
SZ-Z4
SZ-Z5
SZ-Z8
SZ-Z9
SZ-Z34
SZ-Z35
SZ-Z36
SZ-Z37
SC-E02 to E05 SC-E02/G to E05/G
Red LED
Red LED
SC-E02 to E05 SC-E02/G to E05/G
SC-E1 to E4 SC-E1/G to E4/G
CR
SC-E02 to E05 SC-E02/G to E05/G
SC-E02/G to E05/G Red LED
Red LED
SC-E02 to E05
SC-E1 to E4
SC-E1/G to E4/G
Main circuit surge suppression units
Contact ratings
Based on UL and CSA
Rated thermal current (A) Making and breaking current (A)
AC (rating code A600) DC (rating code Q300)
Volts Making
Breaking
Volts Making
Breaking
10 120V 60 6 125V 0.55 0.55
240V 30 3 250V 0.27 0.27
480V 15 1.5
600V 12 1.2
SZ-A11/T
AF88-080
SZ-A22/T
KK02-081
Front mounting
Side mounting
SZ-AS1/T
SZ-AS2/T
Side mounting
SZ-ZM4E
Front mounting
SZ-ZM1E
CR
SZ-Z4
Coil surge suppression unit
AF88-766
KK01-090
KK02-079
KK02-077
Contactors SC-M and SC-E series
Optional accessories
• Power Connection kit for reversing for SC-M and SC-E contactor
Description Applicable contactor Part number
Line side and load side wire kits
Line side wire kit
Load side wire kit
Load side wire kit for the contactor
to be connected with overload relay.
Line side wire kit
Load side wire kit
Load side wire kit for the contactor
to be connected with overload relay.
Line side wire kit
Load side wire kit
Load side wire kit for the contactor
to be connected with overload relay.
SC-M01, M02, M01/G, M02/G
SC-E02 to E05
SC-E02/G to E05/G
SC-E1 to E2S,
SC-E1/G to E2S/G,
SC-E3,E4
SC-E3/G,E4/G
Mass (g)
4.2
19
17
13
48
42
31
162
138
110
SZ-MRWC
SZ-ERW1/A
SZ-ERW1/B
SZ-ERW1/D
SZ-ERW2/A
SZ-ERW2/B
SZ-ERW2/D
SZ-ERW3/A
SZ-ERW3/B
SZ-ERW3/D
• Mechanical interlock unit
• Preparing to make a reversing contactors and motor starters.
Description Applicable contactor Part number
SC-M01, M02, M01/G, M02/G
SC-E02 to E4
SC-E02/G to E4/G
<For SC-M contactor>
1. SC-M_ x 2
2. SZ-MRWC x 1
3. SZ-MRM x 1
<For SC-E contactor>
1. SC-E_ x 2
2. SZ-ERW_/A x 1
3. SZ-ERW_/B x 1
4. SZ-RM x 1
5. SZ-_A/T x 2
<For SC-E motor starters>
1. SC-E_ x 2
2. TK-E_ X1
3. SZ-ERW_/A x 1
4. SZ-ERW_/D x 1
5. SZ-RM x 1
6. SZ-_A/T x 2
Mass (g)
3
27
SZ-MRM
SZ-RM
Contactors SC-M and SC-E series
Optional accessories
AF01-33
KK03-047
KK03-48
AF00-85
Power Connection kit for reversing for
SC-M and SC-E contactor
Mechanical interlock unit
Example of connecting, SC-E reversing motor starterExample of connecting, SC-M reversing contactor
97 95
9698
2/T1
4/T2 6/T3
83
8472
71
84
83
72
71
54
53
A2
A1
6/T3 4/T2
2/T1
53
1/L1
3/L2 5/L3
61
A1
A2
6254
1/L1
3/L2 5/L3
61
62
6/T3 4/T2
2/T1
97 95
9698
2/T1
4/T2 6/T3
54
6/T3 4/T2
2/T1
6254 62
6/T3 4/T2
2/T1
53
A2
A1
53
1/L1
3/L2 5/L3
61
A1
A2
1/L1
3/L2 5/L3
61
2/T1
4/T2 6/T3
6252 62
A2
A1
61
5/L3 3/L2
1/L1
51
2/T1
4/T2 6/T3
52
61
5/L3 3/L2
1/L1
A1
A2
51
97 95
9698
2/T1
4/T2 6/T3
97 95
9698
2/T1
4/T2 6/T3
2/T1
4/T2 6/T3
6254 62
2/T1
4/T2 6/T3
5474 84 74 84
61
5/L3 3/L2
1/L1
A2
A1 A1
A2
53 73 83
61
5/L3 3/L2
1/L1
53 73 83
AUX.2P (1NC) x~2
AUX.4P (3NO) x~2
AUX.2P (1NO) x~2
AUX.4P (2NO+1NC) x~2
38
1 3 5 1 3 5
L1 L2 L5
T1 T2 T3
2 4 6
T122 22T2 T3
2 4 6
L1 L2 L5 21 A1A1
K2 K1
A2 A2
21
39
Contactors SC-M and SC-E series
Contactor
part number
AC coil
part number
Super magnet coil
part number
SC-E02 to E05 4NC0H-#MC N/A
Replacement coils
Replacement coil for SC-M series is not available
Replacement coil for SC-E series, AC coil is available, DC coil is not available
Contactor
part number
SC-E1, E2 and E2S
SC-E3 and E4
SC-E5
SC-E6 and E7
SZ-GM/N1-#
SZ-GM/N2S-#
N/A
N/A
N/A
N/A
SZ-GS/N5-#
SZ-GS/N6-#
Optional accessories
AC coil part number
(Chart 1)
Super magnet coil
part number (Chart 2)
Code letter #
Chart 1 : AC coil
24
48
100
110
120
200
220
400
440
500
24-26V
48-52V
100-110V
110-120V
120-130V
200-220V
220-240V
400-440V
440-480V
550-600
24V
48V
100V
100-110V
110-120V
200V
200-220V
380-400V
415-440V
500-550V
AC coil 60Hz AC coil 50Hz
Code letter #
E
F
A
1
G
B
2
C
4
5
24-26V
48-52V
100-110V
110-120V
120-130V
200-220V
220-240V
400-440V
440-480V
550-600
24V
48V
100V
100-110V
110-120V
200V
200-220V
380-400V
415-440V
500-550V
AC coil 60Hz AC coil 50Hz
Code letter #
Chart 2 : Super magnet coil
24
48
100
200
400
500
24-25V
48-50V
100-127V
200-250V
380-450V
460-575V
24V
48V
100-120V
200-240V
N/A
N/A
AC coil 50/60Hz DC
Replace the # symbol with the desired code, shown in the charts below.
Replace the # symbol with the desired code, shown in the chart below.
40
Contactors SC-M and SC-E series
Dimensions, mm
• Non-reversing AC operated
SC-M01, SC-M02
1NO
1NC
1/L1 3/L2 5/L3 13
1/L1 3/L2 5/L3 21
2/T1 4/T2 6/T3 14
2/T1 4/T2 6/T3 22
A1
A2
A1
A2
Mounting hole
2-M4
Use the two mounting holes on a diagonal
line 1 or 2 to mount a contactor.
2
1
56
7.5
7.6 8.8
48
24.3
45
(9.8)*
2
(9.8)*
2
5
4
42.3
Coil terminal
M3.5
Panel drilling
Aux.terminal
M3.5
Main terminal
M3.5
(37.5)*
1
35
40
67(Mounting rail height 15)
Mass: 0.17kg
*
1
Front mounting aux. contact block
*
2
Side mounting aux. contact block
Aux. contact
Wiring diagrams
• Non-reversing DC operated
SC-M01/G, SC-M02/G
Mounting hole
2-M4
Panel drilling
Coil terminal
M3.5
Aux.terminal
M3.5
Main terminal
M3.5
Mass: 0.23kg
*
1
Front mounting aux. contact block
*
2
Side mounting aux. contact block
1NO
1NC
1/L1 3/L2 5/L3 13 A1
A2
2/T1 4/T2 6/T3 14
1/L1 3/L2 5/L3 21
2/T1 4/T2 6/T3 22
A1
A2
2
1
68
7.5
7.6 8.8
48
24.3
45
(9.8)*
2
(9.8)*
2
5
4
79(Mounting rail height 15)
54.3
(37.5)*
1
35
40
Use the two mounting holes on a diagonal
line 1 or 2 to mount a contactor.
Aux. contact
• Auxiliary contact blocks Front mounting
SZ-MA40, MA31, MA22, MA13, MA04
45
32.5
37.5
10.8
7.6
Aux.terminal
M3.5
Mass: 40g
SZ-MA20, MA11, MA02
45
32.5
37.5
10.8
7.6
M3.5
Aux. terminal
Mass: 30g
53 63 73 83
54 64 74 84
53 61 73 83
54 62 74 84
53 61 71 83
54 62 72 84
53 61 71 81
54 62 72 82
51 61 71 81
52 62 72 82
4NO
4NC
3NO+1NC
1NO+3NC
2NO+2NC
53 63
54 64
53 61
54 62
51 61
52 62
2NO 1NO+1NC
2NC
Dimensions
41
Contactors SC-M and SC-E series
Dimensions, mm
Aux. contact blocks (Side mounting)
SZ-MAS10, MAS01
46
7.6
9.8 45 9.8
24.3
56 Aux. terminal
M3.5
Mass: 18g
Coil sur
Power Connection kit for reversing for SC-M Mechanical interlock unit
ge suppression unit
SZ-MZ1, MZ2, MZ3
21.5
9
17.5
77.5 (SC-M01, M02)
89.5 (SC-M01/G, M02/G)
Mass: 5g
Standard operating conditions
Ambient
temperature
Humidity
Altitude
Atmosphere
Vibration
Shock
Mounting
Mounting
angle
Standard
Operating: –5 to 55˚C
No sudden temperature changes resulting in
condensation or icing (The average temperature over
a 24-hour period must not exceed 35˚C)
Storage:
–40 to 65˚C
45 to 85%RH
2000m or lower
No excessive dust, smoke, corrosive gases,
flammable gases, steam, or salt.
10 to 55Hz 15m/s2
50m/s2
Screw mounting, 35mm-wide top hat rail (DIN)
IEC 60947-4-1, EN 60947-4-1, VDE 0660
JIS C 8201-4-1, JEM 1038
UL 508, CSA C22.2
3
3
30˚
30˚
Wiring diagrams
Aux. contact
63
64
61
62
53
54
51
52
• Mounted on the right side
1NO 1NC
• Mounted on the left side
1NO 1NC
Internal circuit
Line side Load side
A1
A2
+A1
-A2
• Built-in CR • Built-in diode
Wiring
Terminal screw
Connectable wire size
Applicable round crimp terminal
Tightening torque
M3.5
1.25 to 2mm
2
(ø1.2 to 2mm)
7.5mm (R2-3.5)
0.8 to 1.0N·m
Dimensions
3
1
2
1
2 3
5.7
19.5
5.7 17.6 2.7
9.5
13 6.8
13.8
83.220.3
27.6
27.6
18.5
83.2
42
Contactors SC-M and SC-E series
Dimensions, mm
Non-reversing AC operated
SC-E02, E03, E04, E05
Panel drilling
34
13
60
(48 to)52
35
18.5(to 20.5)
14.5
43
80
49 20
(28)
8.5
61
81
91
(68)
10.5
*
1
Mounting hole
2-M4
(Rail height 15)
*
2
*
1
*
2Main
terminal M4
Coil terminal
M3.5
2
1
Mass: 0.33kg
SC-E1, E2, E2S
106 (Rail height 15)
18.5
90
(28)
65.5
96
80
45(38 to 46)
45
75
16.5
57
54
10.5
9.5
5
(79)
2
2
1
Panel drilling
Mounting hole
2-M4
Main
terminal
Coil terminal
M3.5
*
1
*
1
*
2
*
2
Mass : 0.58kg
SC-E3, E4
90 13
72.5
20.5
77
19.5
112
(28)
10.5 67
(55 to)60
(54 to)60
121 (Rail height 15)
111
2.5
(91)
2
1
Panel drilling
Mounting hole
2-M4
Main
terminal
Coil terminal
M3.5
*2
*2*1
*1
Mass: 1.1kg
SC-E5
75
77
32.7 70
132
88
32
155
13.5
129
(111)
4Auxiliary
terminal
M3.5
Panel drilling
Mounting hole
2-M4
Main
terminal
Coil terminal
M3.5
*1
Mass: 2.0kg
*1 Side mounting aux. contact block
*2 Front mounting aux. contact block
Wiring diagrams
*
1
*
1
6/T3 4/T2 2/T1
53 61 1/L1 3/L2 5/L3 83 71
A1 A2
72846254
*
1
In case of aux. contact 2NO+2NC
*
1
In case of aux. contact 2NO+2NC
*
1
*
1
6/T3 4/T2 2/T1
53 61 1/L1 3/L2 5/L3 83 71
A1 A2
72846254
*
1
In case of aux. contact 2NO+2NC
*
1
*
1
6/T3 4/T2 2/T1
53 61 1/L1 3/L2 5/L3 83 71
A1 A2
72846254
*
1
In case of aux. contact 4NO+4NC
6/T3 4/T2 2/T1
*
1
53 61 13 21 1/L1 3/L2 5/L3 43 31 83 71 A1 A2
7284324422146254
*
1
Use the two mounting holes on a diagonal line
or to mount contactor
: 35 60 : 35 (48 to) 52
Use the two mounting holes on a diagonal line
or to mount contactor
: 45 75 : 45 (38 to 46) 80
Use the two mounting holes on a diagonal line
or to mount contactor
: (55 to) 60 90 : (54 to) 60 90
Dimensions
43
Dimensions, mm
Non-reversing AC operated
SC-E6
(80 to)90
110
32
169
143 13.5
100
38.8
138
77 (123)
4Auxiliary
terminal
M3.5
Panel drilling
Mounting hole
2-M5
Main
terminal
Coil terminal
M3.5
*1
Mass: 2.6kg
SC-E7
35
140
38.8
76.8
146 14.5
175
(138)
115 (80 to)90
110
Auxiliary
terminal
M3.5
Panel drilling
Mounting hole
2-M5
Main
terminal
Coil terminal
M3.5
*1
Mass: 2.9kg
Non-reversing DC operated
SC-E02/G, E03/G, E04/G, E05/G
Panel drilling
Mounting hole
2-M4
Main
terminal
M4
Coil terminal
M3.5
*
1
*
1
*
2
*
2
(28)
8.5 88108
118 (Rail height 15)
13
43
80
49 20
(68)
10.5
34
60
(48 to)52
35
18.5(to 20.5)
14.5
2
1
Mass: 0.59kg
SC-E1/G, E2/G, E2S/G
130 (Rail height 15)
18.5
90
(28)
16.5
57
10.5
121.5
91
254
(79)
5
9.5
75
45
45(38 to 46)
80
1
2
Panel drilling
Mounting hole
2-M4
Main
terminal
Coil terminal
M3.5
*
2
*
2
*
1
*
1
Mass: 0.79kg
*1 Side mounting aux. contact block
*2 Front mounting aux. contact block
Wiring diagrams
*
1
In case of aux. contact 4NO+4NC
6/T3 4/T2 2/T1
*
1
53 61 13 21 1/L1 3/L2 5/L3 43 31 83 71 A1 A2
7284324422146254
*
1
*
1
In case of aux. contact 4NO+4NC
6/T3 4/T2 2/T1
*
1
53 61 13 21 1/L1 3/L2 5/L3 43 31 83 71 A1 A2
7284324422146254
*
1
*
1
*
1
6/T3 4/T2 2/T1
53 61 1/L1 3/L2 5/L3 83 71
A1 A2
72846254
*
1
In case of aux. contact 2NO+2NC
*
1
In case of aux. contact 2NO+2NC
*
1
*
1
6/T3 4/T2 2/T1
53 61 1/L1 3/L2 5/L3 83 71
A1 A2
72846254
Use the two mounting holes on a diagonal line
or to mount contactor
: 35 60 : 35 (48 to) 52
Use the two mounting holes on a diagonal line
or to mount contactor
: 45 75 : 45 (38 to 46) 80
Contactors SC-M and SC-E series
Dimensions
44
Contactors SC-M and SC-E series
Dimensions, mm
Non-reversing DC operated
SC-E3/G, E4/G
20.5
77
19.5
112
(28)
91.5
130
140 (Rail height 15)
10.5 2.5 67
(91) (54 to)60
(55 to)60
13
90
1
2
Panel drilling
Mounting hole
2-M4
Coil terminal
M3.5
*
2
*
2
*
1
*
1
Mass: 1.4kg
Main
terminal
Auxiliary contact blocks Front mounting
SZ-A40/T, A31/T, A22/T, A20/T, A11/T, A02/T for SC-E02 to E4
5 25 43
10
11
7.7
10
24
7.7
49
M3.5 M3.5
28
49
28
Approx
3
AC
Approx
3
B
Contactor with aux. contact block
A
B
SZ-A40/T, A31/T, A22/T Mass: 36g
SZ-A20/T, A11/T, A02/T Mass: 20g
Auxiliary contact blocks Side mounting
SZ-AS1/T, for SC-E02 to E4
28
43
59.5
7.7
12 7.5
45
M3.5
A
B
C
12 12D
Contactor with aux. contact block
Mass: 28g
SZ-AS2/T, for SC-E5 to E7
C12 12
A
B
64.5
12
7.7
M3.5
28
47
7
47.5
Contactor with aux. contact block
D
Mass: 40g
Type
SC-E02, E03, E04, E05
SC-E1, E2, E2S
SC-E3, E4
A
43
54
67
B
80
90
112
C
109
124
139
Type
SC-E02, E03, E04, E05
SC-E1, E2, E2S
SC-E3, E4
A
67
78
91
B
80
90
112
C
81
96
111
D
43
54
67
Type
SC-E5
SC-E6
SC-E7
A
112
124
139
B
155
169
175
C
132
138
140
D
88
100
115
Wiring diagrams
53 63 73 83
54 64 74 84
53 61 73 83
54 62 74 84
53 61 71 83
54 62 72 84
4NO
3NO+1NC
2NO+2NC
53 63
54 64
53 61
54 62
51 61
52 62
2NO
1NO+1NC
2NC
1NO+1NC
1NO+1NC
53 61
54 62
71 83
72 84
Mounted on right side
Mounted on left side
53 61
54 62
71 83
72 84
Mounted on right side
Mounted on left side
Use the two mounting holes on a diagonal line
or to mount contactor
: (55 to) 60 90 : (54 to) 60 90
*
1
In case of aux. contact 2NO+2NC
*
1
*
1
6/T3 4/T2 2/T1
53 61 1/L1 3/L2 5/L3 83 71
A1 A2
72846254
*1 Side mounting aux. contact block
*2 Front mounting aux. contact block
Dimensions
45
Contactors SC-M and SC-E series
Dimensions, mm
• Main circuit surge suppression units
Type
SC-E02+SZ-ZM1E
SC-E03
SC-E04
SC-E05
SC-E1+SZ-ZM3E
SC-E2
SC-E2S
SC-E3+SZ-ZM3E
SC-E4
A
43
54
67
B
80
90
112
C
121
136
151
34 4.5
43
45
27
34 4.5
43
45
27
A
B
C Min.5
45
34
SZ-ZM3E
SZ-ZM1E Contactor with surge suppression unit
Mass: 60g
6022
37
39
6022
37
39
C A
B
22
39
D
Type
SC-E02+SZ-ZM2E
SC-E03
SC-E04
SC-E05
SC-E1
SC-E2+SZ-ZM2E
SC-E2S
SC-E3+SZ-ZM2E
SC-E4
A
65
76
89
B
80
90
112
C
81
96
111
D
43.5
49
55.5
SZ-ZM4E
SZ-ZM2E
Contactor with surge suppression unit
Mass: 60g
Connection diagram
5
3
1
6
4
2
Contactor
Thermal overload relay
M
Motor
W
V
U
Main circuit surge suppression unit
Coil surge suppression units
SZ-Z1, Z2, Z3, Z4, Z5
27 10
14
15
26
Mass: 14g
SC-E02 to E05 + SZ-Z1 to Z3
(Built-in varistor)
SC-E02 to E05 + SZ-Z4, Z5
(Built-in CR)
C
R
SZ-Z6, Z7, Z8, Z9
27 10
14
LED LED 35
15
Mass: 16g
SC-E02 to E05 + SZ-Z6, Z7
(Built-in varistor with operating indicator)
R
SC-E02 to E05 + SZ-Z8, Z9
(Built-in CR with operating indicator)
R2
R1
C
SZ-Z31, Z32, Z33, Z34, Z35, Z36, Z37
30
37
12.526
13.5
Mass: 15g
SC-E1 to E4 + SZ-Z31 to Z33
(Built-in varistor)
SC-E1 to E4 + SZ-Z34, Z35
(Built-in CR)
SC-E1/G to E4/G + SZ-Z36, Z37
(Built-in CR)
C
R
Dimensions
46
Contactors SC-M and SC-E series
Dimensions, mm
Power connection kit for reversing for SC-E
SZ-ERW1/A
SZ-ERW1/D
SZ-ERW2/A
SZ-ERW2/D
SZ-ERW2/B
SZ-ERW1/B
Dimensions
About 27
About 22
About 86
82
56
30
82
56
30
18.5
5
17.5
16
86
18.5
17.5
86
82
56
30
916
About 18.5
About 31
18 26
30
2.5
3
100
67
34
100
67
34
About 42
About 31
1
About 22
8 92
About 22
1 8 59
5.517
30.5 106
30.5
10.517
30
2.5
3
106
2/T1 - 6/T3
4/T2 - 4/T2
6/T3 - 2/T1
47
Dimensions, mm
Power connection kit for reversing for SC-E
SZ-ERW3/A SZ-ERW3/B
Contactors SC-M and SC-E series
Dimensions
SZ-ERW3/D
6.5
39
80
121
121
80
39
About 38.5
About 25.5
About 25.5
35.5
35
About 28 About 28
10 29
10 70
10 111
About
22.5
2.5
2.5
2.5
9.520
34
20
6.5
34.5
4
17
130.5
2/T1 - 6/T3
4/T2 - 4/T2
6/T3 - 2/T1
4
48
Contactors SC-M and SC-E series
Standard operating conditions
The magnetic contactors are manufactured for use in the
standard operating conditions given in the table at the right.
Consult FUJI before using the magnetic contactors in different
conditions.
Wirings
• Connection wires and terminal processing
Be sure to perform wiring correctly with reference to the
connections diagram. Main terminals for models SC-E02 to
SC-E7 are wired using solid wires or stranded wires.
Stranded wires or flexible stranded wires can be connected
by twisting them together, crimping a sleeve (ferrule) onto
them before connecting.
Tightening torque
If wires are not tightened sufficiently, they may become hot or
come loose and result in a fire, short-circuit, electric shock, or
some other potentially dangerous situation. Be sure to tighten
the wires to the torques specified in the tables below.
Connectable wire sizes, tightening tools, tightening torques
Main circuit
Contactor type
Solid wire
(mm
2
)
Stranded wire
(mm
2
)
AWG
Sheath stripping length
(mm)
Terminal screw size
Tool
Tightening torque (N·m)
One
Two
One
Two
One
Two
SC-E02
SC-E02/G
0.75 to 4
1 to 4
0.75 to 4
1 to 4
12 max.
12 max.
M4
+
Phillips screwdriver, H-type, No. 2
(ISO 8764)
Flat-blade screwdriver, 1 5.5 L-type, B
(ISO 2830)
1.2 to 1.5
SC-E03
SC-E03/G
SC-E04
SC-E04/G
0.75 to 6
1.5 to 6
0.75 to 6
1.5 to 6
10 max.
10 max.
SC-E05
SC-E05/G
11
SC-E7
4 to 120
2.5 to 95
4 to 95
12 to 250MCM
28.5
4 to 120
2.5 to 95
4 to 95
12 to 250MCM
28.5
4 to 120
2.5 to 95
4 to 95
12 to 250MCM
10
Contactor type SC-E1, E2, E2S
0.75 to 35
0.75 to 25
0.75 to 25
18 to 2
15
0.75 to 25
0.75 to 16
0.75 to 16
18 to 3
12.5
0.75 to 25
0.75 to 16
0.75 to 16
18 to 3
+
Phillips screwdriver, H-type, No. 2
(ISO 8764)
Flat-blade screwdriver, 1 5.5 L-type, B
(ISO 2830)
2.5
1
SC-E3, E4
1.5 to 70
1.5 to 50
1.5 to 50
16 to 2/0
19.5
1.5 to 50
1.5 to 35
1.5 to 35
16 to 1/0
16
1.5 to 50
1.5 to 35
1.5 to 35
16 to 1/0
Hex. wrench 4 (ISO 2936)
8
2
Tool
Tightening torque (N·m)
Self-locking torque (N·m) *
2
SC-E5,
SC-E1/G, E2/G, E2S/G SC-E3/G,
E4/G
E6
4 to 70
2.5 to 50
4 to 50
12 to 2/0
26.5
4 to 70
2.5 to 50
4 to 50
12 to 2/0
26.5
4 to 70
2.5 to 50
4 to 50
12 to 2/0
Top-only
connection
Bottom-only
connection
Top/bottom
connection
Solid or stranded wire (mm
2
) *
1
Flexible stranded wire with sleeve (mm
2
) *
1
Flexible stranded wire without sleeve (mm
2
)
*
1
AWG
Solid or stripping length (mm)
Single stranded wire (mm
2
) *
1
Flexible stranded wire with sleeve (mm
2
) *
1
Flexible stranded wire without sleeve (mm
2
)
*
1
AWG
Sheath stripping length (mm)
Solid or stranded wire (mm
2
) *
1
Flexible stranded wire
with sleeve (mm
2
) *
1
Flexible stranded wire
without sleeve (mm
2
) *
1
AWG
Top/bottom
Top/bottom
Top/bottom
Top/bottom
Operating:
No sudden temperature changes resulting in
condensation or icing (The average temperature over
a 24-hour period must not e
Storage:
45 to 85%RH
2000m or lower
No excessive dust, smoke, corrosive gases,
flammable gases, steam, or salt
10 to 55Hz 15m/s
2
50m/s
2
Screw mounting, 35mm DIN rail mounting
(SC-E02 to SC-E4)
IEC 60947-4-1, EN 60947-4-1, VDE 0660
JIS C 8201-4-1, JEM 1038
UL 508, CSA C22.2
Ambient
temperature
Humidity
Altitude
Atmosphere
Vibration
Shock
Mounting
Mounting
angle
Standard
Notes: *1Stranded wire (0 to 25mm2) consists of 7 wires or less.
Stranded wire (35 to 120mm2) consists of 19 wires or less.
Flexible stranded wire consists of more number wires than the above.
*2The tightening bolt must be loosened in order to insert the wire. However, stop
loosening the bolt when the anti-drop attachment on the bottom of the bolt
reaches the top edge of the terminal. If a torque exceeding that given in the
table is applied in this state, the retaining bracket may come loose.
Control circuit
Instructions
49
Thermal overload relays TK-E series
TK-E series with open-phase protection device
Features
This relay protects motor windings from burning due to
overloads, locked rotor current, or open-phases.
Maintenance and inspection safety has been improved by
employing a finger protection mechanism to cover exposed
terminals (conforms to DIN 57106, VDE 0106 Teil 100).
A high-precision scale for the current adjustment dial enables
easy and exact current setting.
The operating status can be visually checked with ease.
The relays can be manually tripped. A trip-free mechanism is
also provided.
Base unit can be added to enable separate-mounting types
of the TK-E02, E2, and E3 models.
TK-E02 TK-E6
AF01-86 AF01-84
Ampere ranges
TK-E02
0.1–0.15
0.13–0.2
0.15–0.24
0.2–0.3
0.24–0.36
0.36–0.54
0.48–0.72
0.64–0.96
0.8–1.2
0.95–1.45
1.4–2.2
1.7–2.6
2.2–3.4
2.8–4.2
4–6
5–8
6–9
7–11
9–13
12–18
16–22
20–25
4–6
5–8
6–9
7–11
9–13
12–18
18–26
24–36
32–42
40–50
44–54
7–11
9–13
12–18
18–26
24–36
28–40
34–50
45–65
48–68
64–80
18–26
24–36
28–40
34–50
45–65
65–95
85–105
45–65
53–80
65–95
85–125
110–160
TK-E3TK-E2 TK-E5 TK-E6, E6H *
Thermal overload relay type
Part number and specification
Applicable contactor Part
number
Aux.
contact
Trip category No. of heater Power consumption Provided functions
(JIS) elements per pole
SC-E02 to E05, E02/G to E05/G
SC-E1 to E2S, E1/G to E2S/G
SC-E3, E4, E3/G, E4/G
SC-E5
SC-E6, E7
Note: Separerate mounting type is available for TK-E6. The part number is TK-E6H.
TK-E02
TK-E2
TK-E3
TK-E5
TK-E6
1NO+1NC 10A 3 2.2VA
3.8VA
6.6VA
6.6VA
8.0VA
Overload, phase-loss protection
Ambient temperature compensation
Manual or auto reset selectable
Manual trip mechanism
Trip indicator
Standards
IEC 60947-4-1, EN60947-4-1
VDE 0660, JIS C 8201-4-1
UL 508, CSA C22.2
Ordering information
Specify the following:
1. Part number
2. Ampere range
Note: * Applicable only for separate-mounting type. Not applicable for use in combination with a magnetic contactor.
-TK-E 02 0.1–0.15
Ampere range
Product
category
Frame size
Quick reference guide and Ordering information
50
Auxiliary contact ratings
• Based on UL and CSA
Part number Rated insulation Rated thermal Making and breaking current (A)
voltage (V) current (A) AC (rating code B600) DC (rating code R300)
Voltage (V) Making (A) Breaking (A)
TK-E02
TK-E2, E3
TK-E5
TK-E6
600 5 120
240
480
600
30
15
7.5
6
3
1.5
0.75
0.6
Voltage (V) Making (A) Breaking (A)
120
250
0.22
0.11
0.22
0.11
Operating characteristics (mean value)
TK-E02
TK-E2 to E6, E6H
Second Minute
Reference temperature: 20
Multiple of setting value
1
0.8
0.6
0.4
0.3
10
8
6
4
3
2
40
30
20
60
2
3
5
8
10
20
30
50
80
0.8 1 1.5 2 3 4 5 6 7 8 9 10 15
Overcurrent (cold start)
Open-phase
(cold start)
Overcurrent (hot start)
x Ie (A)
Operating time
Second Minute
Reference temperature: 20
Multiple of setting value
1
0.8
0.6
0.4
0.3
10
8
6
4
3
2
40
30
20
60
2
3
5
8
10
20
30
50
80
0.8 1 1.5 2 3 4 5 6 7 8 9 10 15
Overcurrent (cold start)
Open-phase
(cold start)
Overcurrent (hot start)
x Ie (A)
Operating time
Thermal overload relays TK-E series
Characteristics
51
Optional accessories for TK-E series
Base units for separate mounting
The base unit modifies thermal overload relays to separate
mounting that can be mounted to 35mm-wide IEC top hat rail
or secured with screws.
Applicable thermal overload relay Type
TK-E02 SZ-HCE
TK-E2 SZ-HDE
TK-E3 SZ-HEE
Trip indicator
Reports any tripping action at a thermal overload relay through
its LED display.
Applicable thermal Rated voltage Type
overload relay
TK-E02 100–110V AC, 50/60Hz SZ-L100
200–220V AC, 50/60Hz SZ-L200
TK-E2 to TK-E6 100–110V AC, 50/60Hz SZ-L100N2
200–220V AC, 50/60Hz SZ-L200N2
Reset release button
Reset a thermal overload relay from the rear side of the board
or a distant location.
Applicable thermal Load length Type
overload relay (mm)
TK-E02 300 SZ-R1
500 SZ-R2
700 SZ-R3
TK-E2 to TK-E6 300 SZ-R4
500 SZ-R5
700 SZ-R6
Base unit
SZ-HDE
Trip indicator
SZ-L200N2
KK01-108 AF00-291
Reset release button
SZ-R1
Dial cover
SZ-DA
AF88-585 AF88-1056
• Dial cover
Protects the setting current value of a thermal overload relay
from being changed unintentionally.
Applicable thermal overload relay Type
TK-E02 to TK-E6 SZ-DA
Thermal overload relays TK-E series
Optional accessories
52
TK-E5 On-contactor mounting only
67
83
9.8
3232
29
4.9
20.5 20.5
13.5
10.4
68
50
59
101 5
3.7
76.5
115
105
106
106.5
235
Main terminal
Mounting
hole
2-M4
Aux.
terminal
M3.5(NO)
Aux.
terminal
M3.5(NO)
(Resetting
stroke: 4mm)
Reset button
Mass: 0.37kg
TK-E6 On-contactor mounting only
Aux.
terminal
M3.5(NO)
Reset button
(Resetting
stroke: 4mm)
Aux.
terminal
M3.5(NO)
Main
terminal
107.5
77.5
4.9
32 32
9.8
43
60
100
15
32
32 18
118
74
5
A
C
B
122
D
35
Mass: 0.71kg
TK-E6H For separate mounting only
24
8.5
45.5 14.4
60
75.5
22.4
32 32
105
15 35
32 32 18
100
74
118 5 Main
terminal
Aux.
terminal
M3.5(NO)
Mounting hole
2-M5
Aux.
terminal
M3.5(NO)
Reset button
(Resetting stroke: 4mm)
11
Mass: 0.82kg
Wiring diagrams
3-heater element
(NO) (NC)
(NO) (NC)
97 95
98 96 2/T1 4/T2 6/T3
Dimensions, mm
TK-E02
28 10 13 7.7
14
14
37
46.5
53
26.5
A
B
C
77 3
D
M3.5(NC)
Aux.
terminal
Main
terminal
M4
(Resetting
stroke: 3mm)
Reset button
M3.5(NO)
Aux. terminal
Mass: 0.13kg
TK-E2
Aux.
terminal
M3.5(NC)
Main
terminal
Reset button
(Resetting
stroke: 4mm)
M3.5(NO)
A
C
B
592
50.5
16.5 16.5
7.8
67.5
53
16.5
4.9
10.5
54
7.3
16.5
78.5
27.5
D
Aux.
terminal
Mass: 0.25kg
TK-E3
29
20.5 20.5 13.5
68
10.4
4.9
76
60
20.5
9.8
20.5
55.5
97.5 5
A
B
C
D
89.5
Aux.
terminal
M3.5(NO)
Reset button
Main
terminal
Aux.
terminal
M3.5(NO)
(Resetting
stroke: 4mm)
Mass: 0.34kg
D
149
149
Contactor
SC-E1 to E2S
SC-E1/G to E2S/G
A
97
B
123
C
63.5
63.5
D
180
180
Contactor
SC-E3, E4
SC-E3/, E4/G
A
107.5
B
126.5
C
79.5
79.5
C
266.5
274
Contactor
SC-E6
SC-E7
A
123
123
B
124
129
D
45
50
Contactor
SC-E02 to 05
SC-E02/G to 05/G
A
80.5
B
107.5
C
49
49
D
127.5
127.5
Thermal overload relays TK-E series
Dimensions
53
Dimensions, mm
• Base units for separate mounting
SZ-HCE
Mounting
hole
2-M4
Main
terminal
M4
7
67.5
7
84
35
3
813 13
10
5
60
53
51
8
5.5
72
83
47
35
Mass: 55g
SZ-HDE
Main
terminal
Mounting
hole
2-M4
61
14.2 4.5
90
99
7
7.3
16.5 16.510.5
54
40
54
8.5 75.5
99
8.5
100.5
59
5
Mass: 0.1kg
SZ-HEE
Main
terminal
Mounting
hole
2-M4
68
5
100
109.5
10.4
20.5 20.513.5
9
68
50
68
8.5 78
104
8.5
106
64
5
16
Mass: 0.15kg
Trip indicators
SZ-L100, L200
11
3.5
26
Approx.440
8 3
Approx.140
SZ-L100N2, L200N2
Approx.450
8
11
26
Approx.250
• Reset release button
SZ-R1, R2, R3
12 8
Locking nut
M10
Reset
button
L 23.5
6.5
Panel drilling 10.5 to 11
9
Type
SZ-R1
SZ-R2
SZ-R3
L
300
500
700
SZ-R4, R5, R6
8
6.5
16
12
Locking nut
M10
Reset
button
L
9
Type
SZ-R4
SZ-R5
SZ-R6
L
300
500
700
Panel drilling 10.5 to 11
• Dial cover
SZ-DA
2
14
Thermal overload relays TK-E series
Dimensions
54
Standard operating conditions
The thermal overload relays are manufactured for use in the
standard operating conditions given in the table at the right.
Consult FUJI before using the thermal overload in different
conditions.
Wiring
• Connection wires and terminal processing
Be sure to perform wiring correctly referring to the
connection diagram. Main terminals for models TK-E02 to
TK-E6 are wired using solid wires or stranded wires.
Stranded wires or flexible stranded wires can be connected
by twisting them together crimping a sleeve (ferrule) onto
them before connecting.
Tightening torque
If wires are not tightened sufficiently, they may become hot or
come loose and result in a fire, short-circuit, electric shock, or
some other potentially dangerous situation. Be sure to tighten
the wires to the torques specified in the tables below.
Wire sizes, tightening tools, tightening torques
Main circuit
Thermal overload relay type
Base unit type
Solid wire
(mm
2
)
Stranded wire
(mm
2
)
AWG
Sheath stripping length
(mm)
Terminal screw size
Tool
Tightening torque [N·m(lb·in)]
TK-E02
SZ-HCE
0.75 to 4
1 to 4
0.75 to 4
1 to 4
12 max.
12 max.
M4
+
Phillips screwdriver, H-type, No. 2
(ISO 8764)
Flat-blade screwdriver, 1 5.5 L-type, B
(ISO 2830)
1.2 to 1.5 (11 to 13)
One
Two
One
Two
One
Two
11
Operating: –5 to 55˚C
No sudden temperature changes resulting in
condensation or icing (The average temperature over
a 24-hour period must not exceed 35˚C)
Storage:
–40 to 65˚C
45 to 85%RH
No excessive dust, smoke, corrosive gases,
flammable gases, steam, or salt
10 to 55Hz 15m/s2
50m/s2
Ambient
temperature
Humidity
Atmosphere
Vibration
Shock
Control circuit
Single stranded 
wire (mm
2
)
AWG
Sheath stripping length
(mm)
Fork terminal
Terminal screw size
Tool
Tightening torque [N·m(lb·in)]
0.75 to 2.5 (ø1 to ø1.6)
0.75 to 2.5
18 to 14
18 to 14
Max. 7.7mm wide (R2-3.5)
M3.5
Phillips screwdriver, H-type, No. 2
(ISO 8764)
Flat-blade screwdriver, 1 5.5 L-type, B
(ISO 2830)
0.8 to 1 (7 to 9)
One
Two
One
Two
10
Thermal overload relay type
Base unit type
Single stranded wire (mm
2
) *
1
Flexible stranded wire with sleeve (mm
2
) *
1
Flexible stranded wire without sleeve (mm
2
)
AWG
TK-E2
SZ-HDE
0.75 to 16
0.75 to 16
0.75 to 16
6 max.
18
+
Phillips screwdriver, H-type, No. 2
(ISO 8764)
Flat-blade screwdriver, 1 5.5 L-type, B
(ISO 2830)
2.5
TK-E3
SZ-HEE
1.5 to 35
1.5 to 35
1.5 to 35
2 max.
21
Hex. wrench 4 (ISO 2936)
6
TK-E5
TK-E6, E6H
16 to 70
16 to 70
16 to 70
00 max.
23
10
Sheath stripping length (mm)
Tool
Tightening torque (N·m)
Notes: *1Stranded wire (0 to 25mm2) consists of 7 wires or less.
Stranded wire (35 to 120mm2) consists of 19 wires or less.
Flexible stranded wire consists of more number wires than the above.
Thermal overload relays TK-E series
Instructions
55
Combination Starters
KK02-162 KK02-152
Features
The user can assemble a combination starter by combining a
BM3 series manual motor starter and an SC series magnetic
contactor according to the load motor capacity.
The manual motor starter provides overload, phase-loss, and
short-circuit protections for the motor circuit, and
incorporates a dial for flexible adjustment to match the total
load current of the motor.
The magnetic contactor allows remote ON/OFF operation of
the motor circuit with high frequency, and features a electrical
durability of one million operations.
The manual motor starter and magnetic contactor are
connected via link module and mounted to a base plate. BM3RSB-010 + SC-M02 BM3VHB-050 + SC-E2S
Combinations meeting for North American market
• BM3RSB, BM3RHB (General)
Quick reference guide
220-240V AC 440-480V AC
-
-
-
-
-
-
1/2
3/4
1-1/2
-
3
5
5
7-1/2
10
-
-
-
-
-
-
2.2
3.2
6
-
9.6
15.2
15.2
22
28
-
-
-
-
-
3/4
1
2
3
5
7-1/2
10
10
15
20
-
-
-
-
-
1.6
2.1
3.4
4.8
7.6
11
14
14
21
27
BM3RSB-P16
BM3RSB-P25
BM3RSB-P40
BM3RSB-P63
BM3RSB-001
BM3RSB-1P6
BM3RSB-2P5
BM3RSB-004
BM3RSB-6P3
BM3RSB-010
BM3RSB-013
BM3RSB-016
BM3RSB-020
BM3RSB-025
BM3RSB-032
BM3RHB-P16
BM3RHB-P25
BM3RHB-P40
BM3RHB-P63
BM3RHB-001
BM3RHB-1P6
BM3RHB-2P5
BM3RHB-004
BM3RHB-6P3
BM3RHB-010
BM3RHB-013
BM3RHB-016
BM3RHB-020
BM3RHB-025
BM3RHB-032
BZ0LRC09AA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRC09AA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRC09AA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRC09AA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRC09AA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRC09AA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRC09AA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRC09AA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRC09AA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRC09AA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRE32AA
BZ0LRE32GA
-
BZ0BPRE22A
BZ0BPRE22A
-
BZ0BPRE22A
BZ0BPRE22A
-
BZ0BPRE22A
BZ0BPRE22A
-
BZ0BPRE22A
BZ0BPRE22A
-
BZ0BPRE22A
BZ0BPRE22A
-
BZ0BPRE22A
BZ0BPRE22A
-
BZ0BPRE22A
BZ0BPRE22A
-
BZ0BPRE22A
BZ0BPRE22A
-
BZ0BPRE22A
BZ0BPRE22A
-
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE32A
BZ0BPRE32A
SC-M01, M01/G
SC-E02
SC-E02/G
SC-M01, M01/G
SC-E02
SC-E02/G
SC-M01, M01/G
SC-E02
SC-E02/G
SC-M01, M01/G
SC-E02
SC-E02/G
SC-M01, M01/G
SC-E02
SC-E02/G
SC-M01, M01/G
SC-E02
SC-E02/G
SC-M01, M01/G
SC-E02
SC-E02/G
SC-M01, M01/G
SC-E02
SC-E02/G
SC-M01, M01/G
SC-E02
SC-E02/G
SC-M02, M02/G
SC-E02
SC-E02/G
SC-E03
SC-E03/G
SC-E04
SC-E04/G
SC-E04
SC-E04/G
SC-E05
SC-E05/G
SC-E1
SC-E1/G
MMS part number Contactor 
part number
Link module Base plate
HP rating
(HP)
Rated
current (A)
HP rating
(HP)
Rated
current (A)
Part number
0.1-0.16
0.16-0.25
0.25-0.4
0.4-0.63
0.63-1
1-1.6
1.6-2.5
2.5-4
4-6.3
6.3-10
10-13
11-16
14-20
18-25
24-32
Current
range (A)
56
Combination Starter
• BM3RSB, BM3RHB (Type F coordination)
To make an application for Type F condition, You need to prepare BZ0TCRE and BZ0TKUAB accessories separately.
Quick reference guide
220-240V AC 440-480V AC
-
-
-
-
-
-
1/2
3/4
1-1/2
-
3
-
5
5
7-1/2
10
-
-
-
-
-
-
2.2
3.2
6
-
9.6
-
15.2
15.2
22
28
-
-
-
-
-
3/4
1
2
3
5
-
7-1/2
10
10
15
20
-
-
-
-
-
1.6
2.1
3.4
4.8
7.6
-
11
14
14
21
27
BM3RSB-P16
BM3RSB-P25
BM3RSB-P40
BM3RSB-P63
BM3RSB-001
BM3RSB-1P6
BM3RSB-2P5
BM3RSB-004
BM3RSB-6P3
BM3RSB-010
BM3RSB-010
BM3RSB-013
BM3RSB-016
BM3RSB-020
BM3RSB-025
BM3RSB-032
BM3RHB-P16
BM3RHB-P25
BM3RHB-P40
BM3RHB-P63
BM3RHB-001
BM3RHB-1P6
BM3RHB-2P5
BM3RHB-004
BM3RHB-6P3
BM3RHB-010
BM3RHB-010
BM3RHB-013
BM3RHB-016
BM3RHB-020
BM3RHB-025
BM3RHB-032
BZ0LRC09AA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRC09AA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRC09AA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRC09AA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRC09AA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRC09AA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRC09AA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRC09AA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRC09AA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRC09AA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRC09AA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRE32AA
BZ0LRE32GA
-
BZ0BPRE22A
BZ0BPRE22A
-
BZ0BPRE22A
BZ0BPRE22A
-
BZ0BPRE22A
BZ0BPRE22A
-
BZ0BPRE22A
BZ0BPRE22A
-
BZ0BPRE22A
BZ0BPRE22A
-
BZ0BPRE22A
BZ0BPRE22A
-
BZ0BPRE22A
BZ0BPRE22A
-
BZ0BPRE22A
BZ0BPRE22A
-
BZ0BPRE22A
BZ0BPRE22A
-
BZ0BPRE22A
BZ0BPRE22A
-
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE32A
BZ0BPRE32A
65
65
65
65
65
65
50
50
50
25
25
25
25
25
25
25
65
65
65
65
65
65
65
65
65
65
65
65
65
65
50
50
SC-M01, M01/G
SC-E02
SC-E02/G
SC-M01, M01/G
SC-E02
SC-E02/G
SC-M01, M01/G
SC-E02
SC-E02/G
SC-M01, M01/G
SC-E02
SC-E02/G
SC-M01, M01/G
SC-E02
SC-E02/G
SC-M01, M01/G
SC-E02
SC-E02/G
SC-M01, M01/G
SC-E02
SC-E02/G
SC-M01, M01/G
SC-E02
SC-E02/G
SC-M01, M01/G
SC-E02
SC-E02/G
SC-M02, M02/G
SC-E02
SC-E02/G
SC-M02, M02/G
SC-E03
SC-E03/G
SC-E03
SC-E03/G
SC-E04
SC-E04/G
SC-E04
SC-E04/G
SC-E05
SC-E05/G
SC-E1
SC-E1/G
MMS part number Contactor 
part number
Link module
Short-circuit ratings at
480Y/277 AC (kA)
Base plate
HP rating
(HP)
Rated
current (A)
HP rating
(HP)
Rated
current (A)
Part number
0.1-0.16
0.16-0.25
0.25-0.4
0.4-0.63
0.63-1
1-1.6
1.6-2.5
2.5-4
4-6.3
6.3-10
6.3-10
10-13
11-16
14-20
18-25
24-32
Current
range (A)
for BM3RSB for BM3RHB
57
• BM3VSB, BM3VHB (General)
Combination Starter
Quick reference guide
• BM3VSB, BM3VHB (Type F coordination)
220-240V AC 440-480V AC
3
3
5
5
7-1/2
10
10
15
20
9.6
9.6
15.2
15.2
22
28
28
42
54
5
7-1/2
10
10
15
20
30
30
40
7.6
11
14
14
21
27
40
40
52
BM3VSB-010
BM3VSB-013
BM3VSB-016
BM3VSB-020
BM3VSB-025
BM3VSB-032
BM3VSB-040
BM3VSB-050
BM3VSB-063
BM3VHB-010
BM3VHB-013
BM3VHB-016
BM3VHB-020
BM3VHB-025
BM3VHB-032
BM3VHB-040
BM3VHB-050
BM3VHB-063
BZ0LVE51AA
BZ0LVE51GA
BZ0LVE51AA
BZ0LVE51GA
BZ0LVE51AA
BZ0LVE51GA
BZ0LVE51AA
BZ0LVE51GA
BZ0LVE51AA
BZ0LVE51GA
BZ0LVE51AA
BZ0LVE51GA
BZ0LVE51AA
BZ0LVE51GA
BZ0LVE51AA
BZ0LVE51GA
BZ0LVE65AA
BZ0LVE65GA
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE65A
BZ0BPVE65A
SC-E1
SC-E1/G
SC-E1
SC-E1/G
SC-E1
SC-E1/G
SC-E1
SC-E1/G
SC-E1
SC-E1/G
SC-E1
SC-E1/G
SC-E2
SC-E2/G
SC-E2S
SC-E2S/G
SC-E3
SC-E3/G
MMS part number Contactor 
part number
Link module Base plate
HP rating
(HP)
Rated
current (A)
HP rating
(HP)
Rated
current (A)
Part number
6.3-10
10-13
11-16
14-20
18-25
24-32
28-40
35-50
45-63
Current
range (A)
To make an application for Type F condition, You need to prepare BZ0TKUAB accessories separately.
220-240V AC 440-480V AC
3
3
5
5
7-1/2
10
10
15
20
9.6
9.6
15.2
15.2
22
28
28
42
54
5
7-1/2
10
10
15
20
30
30
40
7.6
11
14
14
21
27
40
40
52
BM3VSB-010
BM3VSB-013
BM3VSB-016
BM3VSB-020
BM3VSB-025
BM3VSB-032
BM3VSB-040
BM3VSB-050
BM3VSB-063
BM3VHB-010
BM3VHB-013
BM3VHB-016
BM3VHB-020
BM3VHB-025
BM3VHB-032
BM3VHB-040
BM3VHB-050
BM3VHB-063
BZ0LVE51AA
BZ0LVE51GA
BZ0LVE51AA
BZ0LVE51GA
BZ0LVE51AA
BZ0LVE51GA
BZ0LVE51AA
BZ0LVE51GA
BZ0LVE51AA
BZ0LVE51GA
BZ0LVE51AA
BZ0LVE51GA
BZ0LVE51AA
BZ0LVE51GA
BZ0LVE51AA
BZ0LVE51GA
BZ0LVE65AA
BZ0LVE65GA
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE65A
BZ0BPVE65A
25
25
25
25
25
25
25
25
25
65
65
65
65
65
65
65
65
65
SC-E1
SC-E1/G
SC-E1
SC-E1/G
SC-E1
SC-E1/G
SC-E1
SC-E1/G
SC-E1
SC-E1/G
SC-E1
SC-E1/G
SC-E2
SC-E2/G
SC-E2S
SC-E2S/G
SC-E3
SC-E3/G
MMS part number Contactor 
part number
Link module
Short-circuit ratings at
480Y/277 AC (kA)
Base plate
HP rating
(HP)
Rated
current (A)
HP rating
(HP)
Rated
current (A)
Part number
6.3-10
10-13
11-16
14-20
18-25
24-32
28-40
35-50
45-63
Current
range (A)
for BM3VSB for BM3VHB
58
Combination Starters
Optional accessories
• Link modules
Applicable
MMS
BM3R
BM3V
Applicable magnetic contactor
SC-M01, M02
SC-M01/G, M02/G
SC-E02, E03, E04, E05
SC-E02/G, E03/G, E04/G, E05/G
SC-E1
SC-E1/G
SC-E1, E2, E2S
SC-E1/G, E2/G, E2S/G
SC-E3
SC-E3/G
Operating
coil
AC
DC
AC
DC
AC
DC
AC
DC
AC
DC
Mass
(g)
25
25
25
35
45
60
45
60
65
80
Type
BZ0LRC09AA
BZ0LRC09AA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRE32AA
BZ0LRE32GA
BZ0LVE51AA
BZ0LVE51GA
BZ0LVE65AA
BZ0LVE65GA
(No.KK01-153)
The link module connects the
manual motor starter and
magnetic contactor electrically and
mechanically.
Description
MMS
BM3RSB
Link module
Contactor
SC-M01, M02
Combination
starter
MMS
BM3RSB
Link module
Contactor
SC-E02 to E05
Combination
starter
Base plate
MMS
BM3RHB
Link module
Contactor
SC-E04, E05
Combination
starter
Base plate
• Base plates
Applicable
MMS
BM3R
BM3V
Applicable magnetic contactor
SC-E02, E03, E04, E05
SC-E02/G, E03/G, E04/G, E05/G
SC-E1
SC-E1/G
SC-E1, E2, E2S
SC-E1/G, E2/G, E2S/G
SC-E3
SC-E3/G
Operating
coil
AC
DC
AC
DC
AC
DC
AC
DC
Mass
(g)
100
100
160
160
160
160
195
195
Type
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE32A
BZ0BPRE32A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE65A
BZ0BPVE65A
(No.KK01-155)
The base plate is a plastic plate to
which the combination starter is
mounted. The base plate can then
be mounted to a panel with screws
or to a DIN rail.
Description
Combination starter configurations
• BM3RSB+SC-M01, M02 • BM3RSB+SC-E02 to E05 • BM3RHB+SC-E04, E05
Optional accessories
59
• BM3RHB+SC-E1 • BM3VHB+SC-E1 to E2S • BM3VHB+SC-E3
Base plate
MMS
BM3RHB
Link module
Contactor
SC-E1
Combination
starter
MMS
BM3VHB
Link module
Contactor
SC-E1 to E2S
Combination
starter
Base plate
MMS
BM3VHB
Link module
Contactor
SC-E3
Combination
starter
Base plate
Notes for mounting an MMS and contactor
When the manual motor starter and magnetic contactor are
configured as a combination starter, the nameplate ends up
facing the wrong direction because the coil terminal of the
magnetic contactor faces downward. Use the following
procedure to turn the nameplate upside down.
For SC-E02 to SC-E05 magnetic contactors
• Insert a flat-blade screwdriver between the arc-chamber of
the S phase or V phase and the terminal screw, and lift the
arc-chamber to remove it.
After removing the cover, turn the cover 180 degrees (top to
bottom), then re-mount it onto the magnetic contactor.
Align the cover with the top and bottom terminals and press
it on firmly by hand.
For SC-E1 to SC-E3 magnetic contactors
• Use a Phillips screwdriver to remove the two screws
securing the front and back bodies.
• Remove the front body and turn it 180 degrees (top to
bottom), then re-mount it with the screws.
• Make sure that no foreign matter enters the interior of the
magnetic contactor during this removal and re-mounting
procedure.
Coil terminal
Combination Starters
Optional accessories
60
Combination Starters
Dimensions, mm
• Base plates
BZ0BPRE22A
Base plate
type
BZ0BPRE32A
Applicable type
MMS
BM3RSB
BM3RHB
Contactor
SC-E1, E1/G
Mounting hole
3-M4
55
39 (to 48)
8
8
5
235
247
8
8
40125
102.5
4.5
25
1 35mm wide rail (hight 15mm) x 2
2 75mm wide rail (hight 25mm) x 1
Base plate
type
BZ0BPVE65A
Applicable type
MMS
BM3VSB
BM3VHB
Contactor
SC-E3, E3/G
66
260
270
5
9
9
48 (to 56)
40
125
102.5
8
Mounting hole
3-M4
4
25
1 35mm wide rail (hight 15mm) x 2
2 75mm wide rail (hight 25mm) x 1
Base plate
type
BZ0BPVE51A
Applicable type
MMS
BM3VSB
BM3VHB
Contactor
SC-E1, E2, E2S,
E1/G, E2/G, E2S/G
88
40
125
102.5
8
247
235 5
8
39 (to 48)
55 Mounting hole
3-M4
4.5
25
1 35mm wide rail (hight 15mm) x 2
2 75mm wide rail (hight 25mm) x 1
BZ0BPRE32A
BZ0BPVE65A
Base plate
type
BZ0BPRE22A
Applicable type
MMS
BM3RSB
BM3RHB
Contactor
SC-E02, E03, E04, E05
E02/G, E03/G, E04/G, E05/G
Mounting hole
3-M4
195
205
45
5
40125
7
(26 to)30
5
7
2
21.3
1 35mm wide rail (hight 15mm) x 2
BZ0BPVE51A
Dimensions
61
Dimensions, mm
• Combination
BM3RSB + SC-M01, M02
+ SC-M01/G, SC-M02/G
MMS
BM3RSB
Contactors
SC-E02/G, E03/G, E04/G, E05/G
Link module
BZ0LRE22GA
Base plate
BZ0BPRE22A
Mass (g)
1,065
14.3
6
17.6
5
5
(26 to)30
52
138.8
40125
162.8
109.3
129.3
Mounting
hole
3-M4
13
70
87.3
96.2
13.5
45
55.2
27
13
195
205
5
45
7
7
5.5
1 35mm wide rail (hight 15mm) x 2
BM3RSB + SC-E02/G to E05/G
MMS
BM3RSB
Contactors
SC-E02, E03, E04, E05
Link module
BZ0LRE22AA
Base plate
BZ0BPRE22A
Mass (g)
820
14.3
6
17.6
5
5
(26 to)30
52
111.8
40125
162.8
82.3
102.3
Mounting
hole
3-M4
13
70
87.3
96.2
13.5
45
55.2
27
13
195
205
5
45
7
7
5.5
1 35mm wide rail (hight 15mm) x 2
BM3RSB + SC-E02 to E05
MMS
BM3RSB
Contactors
SC-M01, M02
SC-M01/G, SC-M02/G
Link module
BZ0LRC09AA
BZ0LRC09AA
Mass(g)
540
600
47.5
71
45
62.3
27
3.7
15
54.3
68
8.8
45
14.3 7.15
157.8
156.7 5.1
6
13.53
45
47.5
Mounting hole
3-M4
135
35
27
13
5.5
10
Combination Starters
Dimensions
62
Combination Starters
MMS
BM3RHB
Contactors
SC-E02/G, E03/G, E04/G, E05/G
Link module
BZ0LRE22GA
Base plate
BZ0BPRE22A
Mass (g)
1,085
14.3
17.6
5
5
(26 to)30
52
138.8
40125
162.8
109.3
129.3
Mounting
hole
3-M4
13
70
100.3
3.3
45
55.2
5.5
195
205
5
45
7
7
1 35mm wide rail (hight 15mm) x 2
115.8
BM3RHB + SC-E02/G to E05/G
MMS
BM3RHB
Contactors
SC-E02, E03, E04, E05
Link module
BZ0LRE22AA
Base plate
BZ0BPRE22A
Mass (g)
840
14.3
17.6
5
5
7
(26 to)30
52
111.8
40125
162.8
82.3
102.3
Mounting
hole
3-M4
13
70
100.3
3.3
45
55.2
5.5
195
205
5
45
7
1 35mm wide rail (hight 15mm) x 2
115.8
BM3RHB + SC-E02 to E05
14.3
13.5
45
70
27
13
5.5
32.4
55
8
39 (to 48)
5
235
247
816.5
185.1
Mounting
hole
3-M4
MMS
BM3RSB
Contactors
SC-E1/G
Link module
BZ0LRE32GA
Base plate
BZ0BPRE32A
Mass (g)
1,360
74.5
91.8
100.7
8
8
116
56.5
40125
102.5
162.8
146.5 1 35mm wide rail (hight 15mm) x 2
2 75mm wide rail (hight 25mm) x 1
BM3RSB + SC-E1/G
Dimensions, mm
• Combination
BM3RSB + SC-E1
Mounting
hole
3-M4 14.3
6
13.5
45
70
27
13
5.5
32.4
55
8
39 (to 48)
5
235
247
816.5
185.1
MMS
BM3RSB
Contactors
SC-E1
Link module
BZ0LRE32AA
Base plate
BZ0BPRE32A
Mass (g)
1,135
74.5
91.8
100.7
8
8
90.5
56.5
40125
102.5
137.5
121
1 35mm wide rail (hight 15mm) x 2
2 75mm wide rail (hight 25mm) x 1
Dimensions
63
Combination Starters
BM3RHB + SC-E1/G
BM3V B + SC-E1, E2, E2S
MMS
BM3VSB
BM3VHB
Contactors
SC-E1, E2, E2S
Link module
BZ0LVE51AA
Base plate
BZ0BPVE51A
Mass (g)
1,580
189.5
90.5
40
125
102.5
137.5
63
121
117.5
121.5
137
28
16.5
5.5
3.3
45
66
70
Mounting
hole
3-M4
55
16.5
8 39 (to 48)
235
247
8
88
5
1 35mm wide rail (hight 15mm) x 2
2 75mm wide rail (hight 25mm) x 1
MMS
BM3VSB
BM3VHB
Contactors
SC-E1/G, E2/G, E2S/G
Link module
BZ0LVE51GA
Base plate
BZ0BPVE51A
Mass (g)
1,810
189.5
116
40
125
102.5
162.8
63
146.5
117.5
121.5
137
28
16.5
5.5
3.3
45
66
70
Mounting
hole
3-M4
55
16.5
8 39 (to 48)
235
247
8
88
5
1 35mm wide rail (hight 15mm) x 2
2 75mm wide rail (hight 25mm) x 1
55
839 (to 48)
14.3
22.5
5.5
16.5
8
Mounting
hole
3-M4
70
45
3.3
32.4
5
185.1
235
247
MMS
BM3RHB
Contactors
SC-E1/G
Link module
BZ0LRE32GA
Base plate
BZ0BPRE32A
Mass (g)
1,380
74.5
104.8
120.3
8
8
116
56.5
40125
102.5
162.8
146.5
1
35mm wide rail (hight 15mm) x 2
2
75mm wide rail (hight 25mm) x 1
BM3V B + SC-E1/G, E2/G, E2S/G
Dimensions, mm
• Combination
BM3RHB + SC-E1
MMS
BM3RHB
Contactors
SC-E1
Link module
BZ0LRE32AA
Base plate
BZ0BPRE32A
Mass (g)
1,155
74.5
104.8
8
8
90.5
56.5
40125
102.5
137.5
121
120.3
55
839 (to 48)
14.3
22.5
5.5
16.5
8
Mounting
hole
3-M4
70
45
3.3
32.4
5
185.1
235
247
1 35mm wide rail (hight 15mm) x 2
2 75mm wide rail (hight 25mm) x 1
Dimensions
64
Combination Starters
Dimensions, mm
• Combination
BM3V B + SC-E3
MMS
BM3VSB
BM3VHB
Contactors
SC-E3/G
Link module
BZ0LVE65GA
Base plate
BZ0BPVE65A
Mass (g)
2,400
66
260
270
9
67 (SC-E3/G)
20.5
8
215.5
40125
102.5
116.5
171.2
155
117.5
63
8
121.5
137
Mounting
hole
3-M4 48 (to 56)
9
16.5
28
11
3.3
45
66 70
5
1 35mm wide rail (hight 15mm) x 2
2 75mm wide rail (hight 25mm) x 1
BM3V B + SC-E3/G
MMS
BM3VSB
BM3VHB
Contactors
SC-E3
Link module
BZ0LVE65AA
Base plate
BZ0BPVE65A
Mass (g)
2,080
66
260
270
9
67 (SC-E3)
20.5
8
215.5
40125
102.5
97.5
152.2
136
117.5
63
8
121.5
137
Mounting
hole
3-M4 48 (to 56)
9
16.5
28
11
3.3
45
66
70
5
1 35mm wide rail (hight 15mm) x 2
2 75mm wide rail (hight 25mm) x 1
Dimensions
Combination Starters
Dimensions, mm
• Type F combination
BM3RSB + SC-E02 to E05
MMS
BM3RSB
Contactors
SC-E02, E03, E04, E05
Link module
BZ0LRE22AA
Line side terminal cover Short-circuit alarm contact block
BZ0TCRE BZ0TKUAB
Base plate
BZ0BPRE22A
Mass (g)
895
35mm wide rail (hight 15mm) x 2
Dimensions
Mounting
hole
3-M4
204
208
4
49.3
58.3
5.5
1
2
13.5
4
93.3
78
7
70
3.340125
82.3
102.3
87.3
96.2
111.8
47.3
BM3RSB + SC-M01, M02, M01/G, M02/G
MMS
BM3RSB
BM3RSB
Contactors
SC-M01, M02
SC-M01/G, M02/G
Link module
BZ0LRC09AA
BZ0LRC09AA
Line side terminal cover Short-circuit alarm contact block
BZ0TCRE
BZ0TCRE
BZ0TKUAB
BZ0TKUAB
Base plate
-
-
Mass (g)
615
675
167.6
68
54.3
45
47.3
9
49.3
58.3
45
68.3
53
15
5.5
13
2
13.5
6
45
3.7
62.3
71
Mounting
hole
3-M4
65
66
Combination Starters
Dimensions, mm
• Type F combination
Dimensions
BM3RSB + SC-E1
MMS
BM3RSB
Contactors
SC-E1
Link module
BZ0LRE32AA
Line side terminal cover Short-circuit alarm contact block
BZ0TCRE BZ0TKUAB
Base plate
BZ0BPRE32A
Mass (g)
1,230
1 35mm wide rail (hight 15mm) x 2
2 75mm wide rail (hight 25mm) x 1
47.3
97.8
82.5
74.5
100.7
91.8
40125
8
8
90.5
137.5
121
(Mountinng Rail Width75)
102.5
5.5
13
27
70
13.5
6
58.3
247
232 45
459
55
Mounting
hole
3-M4
BM3RSB + SC-E02/G to E05/G
MMS
BM3RSB
Contactors
SC-E02/G, E03/G, E04/G, E05/G
Link module
BZ0LRE22GA
Line side terminal cover Short-circuit alarm contact block
BZ0TCRE BZ0TKUAB
Base plate
BZ0BPRE22A
Mass (g)
1,160
35mm wide rail (hight 15mm) x 2
96.2
87.3
109.3
129.3
138.8
93.3
78
70
3.340125
47.3
7
7
Mounting
hole
3-M4
13.5
5.5
6
2
1
204
208
9
49.3
58.3
45
45
Combination Starters
Dimensions, mm
• Type F combination
BM3RHB + SC-M01, M02, M01/G, M02/G
Dimensions
Mounting
hole
3-M4
167.6
45
5.5
3.3
9
49.3
58.3
45
47.3
91
75.3
45
68.3
53
15
3.7
62.3
68
54.3
MMS
BM3RHB
BM3RHB
Contactors
SC-M01, M02
SC-M01/G, M02/G
Link module
BZ0LRC09AA
BZ0LRC09AA
Line side terminal cover Short-circuit alarm contact block
BZ0TCRE
BZ0TCRE
BZ0TKUAB
BZ0TKUAB
Base plate
-
-
Mass (g)
635
695
BM3RSB + SC-E1/G
MMS
BM3RSB
Contactors
SC-E1/G
Link module
BZ0LRE32GA
Line side terminal cover Short-circuit alarm contact block
BZ0TCRE BZ0TKUAB
Base plate
BZ0BPRE32A
Mass (g)
1,455
47.3
97.8
82.5
74.5
100.7
91.8
116
162.8
146.5
(Mountinng Rail Width75)
40125
8
8
102.5
1 35mm wide rail (hight 15mm) x 2
2 75mm wide rail (hight 25mm) x 1
5.5
13
27
70
13.5
6
58.3
247
232 45
459
55
Mounting
hole
3-M4
67
68
Combination Starters
Dimensions, mm
• Type F combination
Dimensions
BM3RHB + SC-E02/G to E05/G
MMS
BM3RHB
Contactors
SC-E02/G, E03/G, E04/G, E05/G
Link module
BZ0LRE22GA
Line side terminal cover Short-circuit alarm contact block
BZ0TCRE BZ0TKUAB
Base plate
BZ0BPRE22A
Mass (g)
1,160
35mm wide rail (hight 15mm) x 2
115.8
100.3
87.3
45
5.5
3.3
109.3
129.3
138.8
93.3
78
70
204
208
3.340125
47.3
9
49.3
58.3
45
7
7
Mounting
hole
3-M4
BM3RHB + SC-E02 to E05
MMS
BM3RHB
Contactors
SC-E02, E03, E04, E05
Link module
BZ0LRE22AA
Line side terminal cover Short-circuit alarm contact block
BZ0TCRE BZ0TKUAB
Base plate
BZ0BPRE22A
Mass (g)
915
Mounting
hole
3-M4
35mm wide rail (hight 15mm) x 2
3.3
5.5
115.8
87.3
93.3
78
70
204
208
3.340125
82.3
102.3
111.8
45
47.3
9
49.3
58.3
45
7
7
Combination Starters
Dimensions, mm
• Type F combination
BM3RHB + SC-E1/G
Dimensions
MMS
BM3RHB
Contactors
SC-E1/G
Link module
BZ0LRE32GA
Line side terminal cover Short-circuit alarm contact block
BZ0TCRE BZ0TKUAB
Base plate
BZ0BPRE32A
Mass (g)
1,455
Mounting
hole
3-M4
1 35mm wide rail (hight 15mm) x 2
2 75mm wide rail (hight 25mm) x 1
49.3
120.3
104.8
3.3
5.5
70
58.3
247
232 45
459
47.3
97.8
82.5
74.5
91.8
116
162.8
146.5
(Mountinng Rail Width75)
55
40
125
8
8
102.5
BM3RHB + SC-E1
MMS
BM3RHB
Contactors
SC-E1
Link module
BZ0LRE32AA
Line side terminal cover Short-circuit alarm contact block
BZ0TCRE BZ0TKUAB
Base plate
BZ0BPRE32A
Mass (g)
1,230
Mounting
hole
3-M4
49.3
3.3
5.5
120.3
104.8
70
58.3
247
232 45
459
47.3
97.8
82.5
74.5
91.8
55
40125
8
8
90.5
137.5
121
(Mountinng Rail Width75)
102.5
1 35mm wide rail (hight 15mm) x 2
2 75mm wide rail (hight 25mm) x 1
69
Combination Starters
Dimensions, mm
• Type F combination
Dimensions
MMS
BM3VSB,VHB
Contactors
SC-E1/G,E2/G,E2S/G
Link module
BZ0LVE51GA
Line side terminal cover Short-circuit alarm contact block
- BZ0TKUAB
Base plate
BZ0BPVE51A
Mass (g)
1,855
116
162.8
146.5
(Mountinng Rail Width75)
91.5
108.8
110.8
47.3
40125
102.5
117.5
121.5
137
8
8
120
232
66
45
3.3
90
9
5.5
70
55
247
1 35mm wide rail (hight 15mm) x 2
2 75mm wide rail (hight 25mm) x 1
Mounting
hole
3-M4
MMS
BM3VSB,VHB
Contactors
SC-E1,E2,E2S
Link module
BZ0LVE51AA
Line side terminal cover Short-circuit alarm contact block
- BZ0TKUAB
Base plate
BZ0BPVE51A
Mass (g)
1,625
Mounting
hole
3-M4
1 35mm wide rail (hight 15mm) x 2
2 75mm wide rail (hight 25mm) x 1
120
232
66
45
3.3
90
9
91.5
108.8
110.8
47.3
90.5
40125
102.5
137.5
121
(Mountinng Rail Width75)
117.5
121.5
137
5.5
70
55
247
8
8
70
BM3V B + SC-E1, E2, E2S
BM3V B + SC-E1/G, E2/G, E2S/G
Combination Starters
Dimensions, mm
• Type F combination
Dimensions
MMS
BM3VSB,VHB
Contactors
SC-E3/G
Link module
BZ0LVE65GA
Line side terminal cover Short-circuit alarm contact block
- BZ0TKUAB
Base plate
BZ0BPVE65A
Mass (g)
2,445
Mounting
hole
3-M4
256
66
270
67
11
70
120
66
45
3.3
90
9
1 35mm wide rail (hight 15mm) x 2
2 75mm wide rail (hight 25mm) x 1
(Mountinng Rail Width75)
116.5
171.2
155
47.3
102.5
125 40
8
108.8
110.8
117.5
121.5
137
891.5
MMS
BM3VSB,VHB
Contactors
SC-E3
Link module
BZ0LVE65AA
Line side terminal cover Short-circuit alarm contact block
- BZ0TKUAB
Base plate
BZ0BPVE65A
Mass (g)
2,125
Mounting
hole
3-M4
1 35mm wide rail (hight 15mm) x 2
2 75mm wide rail (hight 25mm) x 1
256
66
270
67
11
70
120
66
45
3.3
90
9
47.3
(Mountinng Rail Width75)
97.5
102.5
125 40
8
152.2
136
91.5
108.8
110.8
117.5
121.5
137
8
71
BM3V B + SC-E3
BM3V B + SC-E3/G
72
List Price for BM3 Series Manual Motor Starters
32A Frame types
Part number
Standard breaking capacity
Discount code List Price
BM3RSB-P16
BM3RSB-P25
BM3RSB-P40
BM3RSB-P63
BM3RSB-001
BM3RSB-1P6
BM3RSB-2P5
BM3RSB-004
BM3RSB-6P3
BM3RSB-010
BM3RSB-013
BM3RSB-016
BM3RSB-020
BM3RSB-025
BM3RSB-032
80.00
80.00
80.00
80.00
80.00
80.00
80.00
80.00
80.00
90.00
90.00
90.00
90.00
100.00
150.00
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
Part number
High breaking capacity
Discount code List Price
BM3RHB-P16
BM3RHB-P25
BM3RHB-P40
BM3RHB-P63
BM3RHB-001
BM3RHB-1P6
BM3RHB-2P5
BM3RHB-004
BM3RHB-6P3
BM3RHB-010
BM3RHB-013
BM3RHB-016
BM3RHB-020
BM3RHB-025
BM3RHB-032
100.00
100.00
100.00
100.00
100.00
100.00
100.00
100.00
100.00
110.00
110.00
110.00
110.00
120.00
170.00
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
63A Frame types
Part number
Standard breaking capacity
Discount code List Price
BM3VSB-010
BM3VSB-013
BM3VSB-016
BM3VSB-020
BM3VSB-025
BM3VSB-032
BM3VSB-040
BM3VSB-050
BM3VSB-063
170.00
170.00
170.00
170.00
190.00
210.00
210.00
230.00
230.00
D14
D14
D14
D14
D14
D14
D14
D14
D14
Part number
High breaking capacity
Discount code List Price
BM3VHB-010
BM3VHB-013
BM3VHB-016
BM3VHB-020
BM3VHB-025
BM3VHB-032
BM3VHB-040
BM3VHB-050
BM3VHB-063
260.00
260.00
260.00
260.00
290.00
310.00
310.00
330.00
330.00
D14
D14
D14
D14
D14
D14
D14
D14
D14
73
List Price for BM3 Series Manual Motor Starters accessories
Part number Description
BZ0WIA
BZ0WIB
BZ0WUAAL
BZ0WUABL
BZ0WUBBL
BZ0WUAAR
BZ0WUABR
BZ0WUBBR
Auxliary contact block (W)
Alarm contact block (K)
Front mounting Auxiliary contact - Internal type 1NO
Front mounting Auxiliary contact - Internal type 1NC
Left side mounting Auxiliary contact - Lateral type 2NO
Left side mounting Auxiliary contact - Lateral type 1NO+1NC
Left side mounting Auxiliary contact - Lateral type 2NC
Right side mounting Auxiliary contact - Lateral type 2NO
Right side mounting Auxiliary contact - Lateral type 1NO+1NC
Right side mounting Auxiliary contact - Lateral type 2NC
Discount code List Price
8.50
8.50
12.00
12.00
12.00
12.00
12.00
12.00
D14
D14
D14
D14
D14
D14
D14
D14
BZ0KIA
BZ0KIB
Front (right side only) mounting Alarm contact - Internal type 1NO
Front (right side only) mounting Alarm contact - Internal type 1NC
9.00
9.00
D14
D14
Auxliary and alarm contact blocks (WK)
BZ0WKUAA
BZ0WKUBA
BZ0WKUAB
BZ0WKUBB
Left side mounting Auxiliary and Alarm contact 1NO(Aux.)+1NO(Alarm)
Left side mounting Auxiliary and Alarm contact 1NC(Aux.)+1NO(Alarm)
Left side mounting Auxiliary and Alarm contact 1NO(Aux.)+1NC(Alarm)
Left side mounting Auxiliary and Alarm contact 1NC(Aux.)+1NC(Alarm)
18.00
18.00
18.00
18.00
D14
D14
D14
D14
Short-circuit alarm contact block (KI)
BZ0TKUAB Left side mounting Short Circuit Alarm contact 1NO+1NC 20.00D14
Shunt trip devices (F)
BZ0FAZU
BZ0FBZU
BZ0FCZU
BZ0F1ZU
BZ0FDZU
BZ0FEZU
BZ0FFZU
BZ0FGZU
BZ0FHZU
BZ0F4ZU
BZ0FJZU
BZ0FKZUD
BZ0FLZUD
Right side mounting Shunt trip / Coil voltage 24VAC 50/60Hz
Right side mounting Shunt trip / Coil voltage 48VAC 60Hz
Right side mounting Shunt trip / Coil voltage 48VAC 50Hz / 60VAC 60Hz
Right side mounting Shunt trip / Coil voltage 100VAC 50Hz / 100-110VAC 60Hz
Right side mounting Shunt trip / Coil voltage 110-127VAC 50Hz / 120VAC 60Hz
Right side mounting Shunt trip / Coil voltage 200VAC 50Hz / 200-220VAC 60Hz
Right side mounting Shunt trip / Coil voltage 220-230VAC 50Hz / 240-260VAC 60Hz
Right side mounting Shunt trip / Coil voltage 240VAC 50Hz / 277VAC 60Hz
Right side mounting Shunt trip / Coil voltage 380-400VAC 50Hz / 400-440VAC 60Hz
Right side mounting Shunt trip / Coil voltage 415-440VAC 50Hz / 460-480VAC 60Hz
Right side mounting Shunt trip / Coil voltage 500VAC 50Hz / 600VAC 60Hz
Right side mounting Shunt trip / Coil voltage 24-60VDC
Right side mounting Shunt trip / Coil voltage 110-240VDC
34.00
34.00
34.00
34.00
34.00
34.00
34.00
34.00
34.00
34.00
34.00
34.00
34.00
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
Undervoltage trip devices (R)
BZ0RAZ1U
BZ0RAZ2U
BZ0RBZ1U
BZ0RBZU
BZ0R1ZU
BZ0RDZU
BZ0REZU
BZ0RFZU
BZ0RGZU
BZ0RHZU
BZ0R4ZU
BZ0RJZU
Right side mounting Undervoltage trip / Coil voltage 24VAC 50Hz
Right side mounting Undervoltage trip / Coil voltage 24VAC 60Hz
Right side mounting Undervoltage trip / Coil voltage 48VAC 50Hz
Right side mounting Undervoltage trip / Coil voltage 48VAC 60Hz
Right side mounting Undervoltage trip / Coil voltage 100VAC 50Hz / 100-110VAC 60Hz
Right side mounting Undervoltage trip / Coil voltage 110-127VAC 50Hz / 120VAC 60Hz
Right side mounting Undervoltage trip / Coil voltage 200VAC 50Hz / 200-220VAC 60Hz
Right side mounting Undervoltage trip / Coil voltage 220-230VAC 50Hz / 240-260VAC 60Hz
Right side mounting Undervoltage trip / Coil voltage 240VAC 50Hz / 277VAC 60Hz
Right side mounting Undervoltage trip / Coil voltage 380-400VAC 50Hz / 400-440VAC 60Hz
Right side mounting Undervoltage trip / Coil voltage 415-440VAC 50Hz / 460-480VAC 60Hz
Right side mounting Undervoltage trip / Coil voltage 500VAC 50Hz / 600VAC 60Hz
34.00
34.00
34.00
34.00
34.00
34.00
34.00
34.00
34.00
34.00
34.00
34.00
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
Line side terminal cover
BZ0TCRE Line side terminal cover for BM3R 18.00D14
External operating handles
BZ0VBBL
BZ0VYRL
BZ0VBBM
BZ0VYRM
External operating handle Standard type (Black) for BM3RH
External operating handle Emergency type (Red / Yellow) for BM3RH
External operating handle Standard type (Black) for BM3V
External operating handle Emergency type (Red / Yellow) for BM3V
40.00
45.00
40.00
45.00
D14
D14
D14
D14
Others
BZ0SET
BZ0TCV
BZ0CFG
Push-in lug for BM3R (10pcs/pack)
IP 20 Terminal cover for BM3V (6pcs/pack)
Dummy cover (10pcs/pack)
8.00
12.00
40.00
D14
D14
D14
74
List Price for BM3 Series Manual Motor Starters accessories
Part number Description
BZ0BR02A
BZ0BR03A
BZ0BR04A
BZ0BR05A
BZ0BR12A
BZ0BR13A
BZ0BR14A
BZ0BR15A
BZ0BR22A
BZ0BR24A
BZ0BV02A
BZ0BV03A
BZ0BV04A
BZ0BV12A
BZ0BV13A
BZ0BV14A
BZ0BV22A
BZ0BV24A
BZ0BFRA
BZ0BFVA
BZ0BCRA
BZ0BCRB
BZ0BCVA
Busbar system
Enclosure
Busbar / 2-BM3R, modular space : 45mm
Busbar / 3-BM3R, modular space : 45mm
Busbar / 4-BM3R, modular space : 45mm
Busbar / 5-BM3R, modular space : 45mm
Busbar / 2-BM3R+1(9mm) external accessory, modular space : 54mm
Busbar / 3-BM3R+1(9mm) external accessory, modular space : 54mm
Busbar / 4-BM3R+1(9mm) external accessory, modular space : 54mm
Busbar / 5-BM3R+1(9mm) external accessory, modular space : 54mm
Busbar / 2-BM3R+1(18mm) or 2(9mm) external accessories, modular space : 63mm
Busbar / 4-BM3R+1(18mm) or 2(9mm) external accessories, modular space : 63mm
Busbar / 2-BM3V, modular space : 55mm
Busbar / 3-BM3V, modular space : 55mm
Busbar / 4-BM3V, modular space : 55mm
Busbar / 2-BM3V+1(9mm) external accessory, modular space : 64mm
Busbar / 3-BM3V+1(9mm) external accessory, modular space : 64mm
Busbar / 4-BM3V+1(9mm) external accessory, modular space : 64mm
Busbar / 2-BM3V+1(18mm) or 2(9mm) external accessories, modular space : 73mm
Busbar / 4-BM3V+1(18mm) or 2(9mm) external accessories, modular space : 73mm
3-phase feed-in terminal for BM3R
3-phase feed-in terminal for BM3V
Busbar cover for BZ0BR (pin connection)
Busbar cover for BZ0BR (fork connection)
Busbar cover for BZ0BV (pin connection)
Discount code List Price
19.00
23.00
27.00
28.00
20.00
24.00
28.00
30.00
44.00
54.00
42.00
53.00
65.00
46.00
59.00
70.00
50.00
78.00
23.00
48.00
6.00
6.00
8.00
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
BZ0CSLA
BZ0CSLB
BZ0CFLA
BZ0CFLB
BZ0CKA
BZ0CPM
BZ0CPL
BZ0CPK
BZ0CCA
BZ0CUA
BZ0CNA
BZ0CLGA
BZ0CLGB
BZ0CLGC
BZ0CLGD
BZ0CLGE
BZ0CLRA
BZ0CLRB
BZ0CLRC
BZ0CLRD
BZ0CLRE
BZ0CLCA
BZ0CLCB
BZ0CLCC
BZ0CLCD
BZ0CLCE
Enclosure Surface mounting type IP41
Enclosure Surface mounting type IP55 with conversion kits
Enclosure Flush mounting type IP41
Enclosure Flush mounting type IP55 with conversion kits
Padlocking device
Emergency pushbutton / Momentary
Emergency pushbutton / Puch-lock turn reset
Emergency pushbutton / Key operated
Conversion kit from IP41 to IP55
Adapter set
Neutral connector
Indication Lamp / Green, 100-120VAC
Indication Lamp / Green, 200-240VAC
Indication Lamp / Green, 380-440VAC
Indication Lamp / Green, 480-500VAC
Indication Lamp / Green, 500-600VAC
Indication Lamp / Red, 100-120VAC
Indication Lamp / Red, 200-240VAC
Indication Lamp / Red, 380-440VAC
Indication Lamp / Red, 480-500VAC
Indication Lamp / Red, 500-600VAC
Indication Lamp / Transparent, 100-120VAC
Indication Lamp / Transparent, 200-240VAC
Indication Lamp / Transparent, 380-440VAC
Indication Lamp / Transparent, 480-500VAC
Indication Lamp / Transparent, 500-600VAC
40.00
57.00
40.00
51.00
30.00
39.00
40.00
82.00
12.00
11.00
4.00
33.00
33.00
33.00
33.00
33.00
33.00
33.00
33.00
33.00
33.00
33.00
33.00
33.00
33.00
33.00
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
75
List Price for SC-E Series Contactors and
TK-E Series Overload Relays and accessories
Contactors Overload Relays
Part number
AC operating coil
List PriceDiscount code
SC-M01
SC-M02
SC-E02
SC-E03
SC-E04
SC-E05
SC-E1
SC-E2
SC-E2S
SC-E3
SC-E4
40.00
40.00
33.00
40.00
54.00
65.00
78.00
108.00
130.00
140.00
160.00
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
Part number
DC operating coil
List PriceDiscount code
SC-M01/G
SC-M02/G
SC-E02/G
SC-E03/G
SC-E04/G
SC-E05/G
SC-E1/G
SC-E2/G
SC-E2S/G
SC-E3/G
SC-E4/G
57.00
57.00
38.00
60.00
80.00
94.00
99.00
130.00
158.00
175.00
200.00
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
Part number
Overload Relays
List PriceDiscount code
-
-
-
-
-
-
TK-E02
TK-E02
TK-E02
TK-E02
TK-E2
TK-E2
TK-E2
TK-E3
TK-E3
42.00
42.00
42.00
42.00
80.00
80.00
80.00
90.00
90.00
D14
D14
D14
D14
D14
D14
D14
D14
D14
SC-E5
SC-E6
SC-E7
Super magnet operating coil
360.00
460.00
535.00
D14
D14
D14
TK-E5
TK-E6
TK-E6
TK-E6H
100.00
148.00
148.00
148.00
D14
D14
D14
D14
List Price for SC-E Series Contactors and TK-E Series Overload Relays
Part number Description
Auxliary contact block
Discount code List Price
SZ-MA40
SZ-MA31
SZ-MA22
SZ-MA13
SZ-MA04
SZ-MA20
SZ-MA11
SZ-MA02
SZ-MAS10
SZ-MAS01
SZ-A40/T
SZ-A31/T
SZ-A22/T
SZ-A20/T
SZ-A11/T
SZ-A02/T
SZ-AS1/T
SZ-AS2/T
Front mounting Auxliary contact block (4NO) for SC-M01(/G), SC-M02(/G)
Front mounting Auxliary contact block (3NO+1NC) for SC-M01(/G), SC-M02(/G)
Front mounting Auxliary contact block (2NO+2NC) for SC-M01(/G), SC-M02(/G)
Front mounting Auxliary contact block (1NO+3NC) for SC-M01(/G), SC-M02(/G)
Front mounting Auxliary contact block (4NC) for SC-M01(/G), SC-M02(/G)
Front mounting Auxliary contact block (2NO) for SC-M01(/G), SC-M02(/G)
Front mounting Auxliary contact block (1NO+1NC) for SC-M01(/G), SC-M02(/G)
Front mounting Auxliary contact block (2NC) for SC-M01(/G), SC-M02(/G)
Side mounting Auxliary contact block (1NO) for SC-M01(/G), SC-M02(/G)
Side mounting Auxliary contact block (1NC) for SC-M01(/G), SC-M02(/G)
Front mounting Auxliary contact block (4NO) for SC-E02(/G) to SC-E4(/G)
Front mounting Auxliary contact block (3NO+1NC) for SC-E02(/G) to SC-E4(/G)
Front mounting Auxliary contact block (2NO+2NC) for SC-E02(/G) to SC-E4(/G)
Front mounting Auxliary contact block (2NO) for SC-E02(/G) to SC-E4(/G)
Front mounting Auxliary contact block (1NO+1NC) for SC-E02(/G) to SC-E4(/G)
Front mounting Auxliary contact block (2NC) for SC-E02(/G) to SC-E4(/G)
Side mounting Auxliary contact block (1NO+1NC) for SC-E02(/G) to SC-E4(/G)
Side mounting Auxliary contact block (1NO+1NC) for SC-E5 to SC-E7
30.00
30.00
30.00
30.00
30.00
25.00
25.00
25.00
15.00
15.00
20.00
20.00
20.00
14.00
14.00
14.00
22.00
22.00
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
Main circuit surge suppression unit
SZ-ZM1E
SZ-ZM2E
SZ-ZM3E
SZ-ZM4E
Front mounting Main circuit surge suppression unit for SC-E02(/G) to SC-E05(/G)
Side mounting Main circuit surge suppression unit for SC-E02(/G) to SC-E05(/G)
Front mounting Main circuit surge suppression unit for SC-E1(/G) to SC-E4(/G)
Side mounting Main circuit surge suppression unit for SC-E1(/G) to SC-E4(/G)
38.00
38.00
40.00
40.00
D14
D14
D14
D14
List Price for SC-E Series Contactors and TK-E Series Overload Relays accessories
76
List Price for SC-E Series Contactors and
TK-E Series Overload Relays accessories
Part number Description
SZ-MZ1
SZ-MZ2
SZ-MZ3
SZ-Z1
SZ-Z2
SZ-Z3
SZ-Z6
SZ-Z7
SZ-Z31
SZ-Z32
SZ-Z33
SZ-Z4
SZ-Z5
SZ-Z8
SZ-Z9
SZ-Z34
SZ-Z35
SZ-Z36
SZ-Z37
Coil surge suppression unit
Power connection kit for reversing
Coil surge suppression unit CR type 12-60VAC for SC-M01, SC-M02
Coil surge suppression unit CR type 72-250VAC for SC-M01, SC-M02
Coil surge suppression unit Diode type 6-250VDC for SC-M01/G, SC-M02/G
Coil surge suppression unit Varistor type 24-48VAC/DC for SC-E02(/G) to SC-E05(/G)
Coil surge suppression unit Varistor type 100-250VAC/DC for SC-E02(/G) to SC-E05(/G)
Coil surge suppression unit Varistor type 380-440VAC/DC for SC-E02 to SC-E05
Coil surge suppression unit Varistor type 24-48VAC/DC with LED for SC-E02(/G) to SC-E05(/G)
Coil surge suppression unit Varistor type 100-250VAC/DC with LED for SC-E02(/G) to SC-E05(/G)
Coil surge suppression unit Varistor type 24-48VAC/DC for SC-E1(/G) to SC-E4(/G)
Coil surge suppression unit Varistor type 100-250VAC/DC for SC-E1(/G) to SC-E4(/G)
Coil surge suppression unit Varistor type 380-440VAC/DC for SC-E1 to SC-E4
Coil surge suppression unit CR type 24-48VAC/DC for SC-E02(/G) to SC-E05(/G)
Coil surge suppression unit CR type 100-250VAC/DC for SC-E02(/G) to SC-E05(/G)
Coil surge suppression unit CR type 24-48VAC/DC with LED for SC-E02(/G) to SC-E05(/G)
Coil surge suppression unit CR type 100-250VAC/DC with LED for SC-E02(/G) to SC-E05(/G)
Coil surge suppression unit CR type 24-48VAC/DC for SC-E1 to SC-E4
Coil surge suppression unit CR type 100-250VAC/DC for SC-E1 to SC-E4
Coil surge suppression unit CR type 24-48VAC/DC for SC-E1/G to SC-E4/G
Coil surge suppression unit CR type 100-250VAC/DC for SC-E1/G to SC-E4/G
Discount code List Price
5.00
5.00
5.00
13.00
13.00
13.00
17.00
17.00
22.00
22.00
22.00
13.00
13.00
17.00
17.00
23.00
23.00
23.00
23.00
D14
D14
D14
D1
D1
D1
D1
D1
D1
D1
D1
D1
D1
D1
D1
D1
D1
D1
D1
SZ-MRWC
SZ-ERW1/A
SZ-ERW1/B
SZ-ERW1/D
SZ-ERW2/A
SZ-ERW2/B
SZ-ERW2/D
SZ-ERW3/A
SZ-ERW3/B
SZ-ERW3/D
Power connection kit for reversing line side and load side for SC-M01(/G), SC-M02(/G)
Power connection kit for reversing line side for SC-E02(/G) to SC-E05(/G)
Power connection kit for reversing load side for Reversing Contactor SC-E02(/G) to SC-E05(/G)
Power connection kit for reversing load side for Reversing Motor Starter SC-E02(/G) to SC-E05(/G)
Power connection kit for reversing line side for SC-E1(/G) to SC-E2S(/G)
Power connection kit for reversing load side for Reversing Contactor SC-E1(/G) to SC-E2S(/G)
Power connection kit for reversing load side for Reversing Motor Starter SC-E1(/G) to SC-E2S(/G)
Power connection kit for reversing line side for SC-E3(/G) to SC-E4(/G)
Power connection kit for reversing load side for Reversing Contactor SC-E3(/G) to SC-E4(/G)
Power connection kit for reversing load side for Reversing Motor Starter SC-E3(/G) to SC-E4(/G)
18.00
10.00
10.00
10.00
20.00
20.00
20.00
40.00
40.00
40.00
D14
D14
D14
D14
D14
D14
D14
D14
D14
D14
Mechanical interlock unit
SZ-MRM
SZ-RM
Mechanical interlock unit for SC-M01(/G), SC-M02(/G)
Mechanical interlock unit for SC-E02(/G) to SC-E4(/G)
4.00
20.00
D14
D1
Base unit for separate mounting
SZ-HCE
SZ-HDE
SZ-HEE
Separate mounting base unit for TK-E02
Separate mounting base unit for TK-E2
Separate mounting base unit for TK-E3
10.00
20.00
25.00
D14
D14
D14
Trip indicator
SZ-L100
SZ-L200
SZ-L100N2
SZ-L200N2
Trip indicator 100-110VAC for TK-E02
Trip indicator 200-220VAC for TK-E02
Trip indicator 100-110VAC for TK-E2 to TK-E6
Trip indicator 100-110VAC for TK-E2 to TK-E6
15.00
15.00
15.00
15.00
D1
D1
D1
D1
Reset release button
SZ-R1
SZ-R2
SZ-R3
SZ-R4
SZ-R5
SZ-R6
Reset release button 300mm for TK-E02
Reset release button 500mm for TK-E02
Reset release button 700mm for TK-E02
Reset release button 300mm for TK-E2 to TK-E6
Reset release button 500mm for TK-E2 to TK-E6
Reset release button 700mm for TK-E2 to TK-E6
96.00
112.00
127.00
100.00
120.00
135.00
D1
D1
D1
D1
D1
D1
Dial cover
SZ-DA Dial cover for TK-E02 to TK-E6 2.00D1
List Price for SC-E Series Contactors and TK-E Series Overload Relays accessories
4NC0H-#MC
SZ-GM/N1-#
SZ-GM/N2S-#
SZ-GS/N5-#
SZ-GS/N6-#
Replacement coil
Replacement coil for SC-E02 to SC-E05 (# : operating coil voltage code)
Replacement coil for SC-E1 to SC-E2S (# : operating coil voltage code)
Replacement coil for SC-E3 to SC-E4 (# : operating coil voltage code)
Replacement coil for SC-E5 (# : operating coil voltage code)
Replacement coil for SC-E6 to SC-E7 (# : operating coil voltage code)
30.00
30.00
31.00
250.00
276.00
D1
D1
D1
D1
D1
77
List Price for Combination Starters accessories
Part number Description
BZ0LRC09AA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRE32AA
BZ0LRE32GA
BZ0LVE51AA
BZ0LVE51GA
BZ0LVE65AA
BZ0LVE65GA
Base plates
Link module for BM3R and SC-M01(/G), SC-M02(/G)
Link module for BM3R and SC-E02 to SC-E05
Link module for BM3R and SC-E02/G to SC-E05/G
Link module for BM3R and SC-E1
Link module for BM3R and SC-E1/G
Link module for BM3V and SC-E1 to E2S
Link module for BM3V and SC-E1/G to E2S/G
Link module for BM3V and SC-E3
Link module for BM3V and SC-E3/G
Discount code List Price
15.00
15.00
20.00
18.00
20.00
18.00
22.00
24.00
28.00
D14
D14
D14
D14
D14
D14
D14
D14
D14
BZ0BPRE22A
BZ0BPRE32A
BZ0BPVE51A
BZ0BPVE65A
Base plate for BM3R and SC-E02(/G) to SC-E05(/G)
Base plate for BM3R and SC-E1(/G)
Base plate for BM3V and SC-E1(/G) to SC-E2S(/G)
Base plate for BM3V and SC-E3(/G)
22.00
24.00
26.00
30.00
D14
D14
D14
D14
Appendix 1 : Construction of combination motor controllers
The UL508 standard defines 6 categories depending on the construction type for the combination motor controllers. The type
and component function is shown below.
Fuji MMS is indicated on the label with "Manual Self-Protected Combination Motor Controller" (TYPE E) and "Combination
Motor Controller" (TYPE F).
Type Component
standard
A
B
C
D
E
F
Component
Manual disconnect
Fuse
Magnetic
Overload relay
Manual disconnect
Motor short-circuit Protector
Magnetic
Overload relay
Inverse time Circuit Breaker
Magnetic
Overload relay
Instantaneous Circuit Breaker
Magnetic
Overload relay
Self-Protected control device
Manual Self-protected combination motor controller
Magnetic
UL98,UL1087
UL248
UL508
UL508
UL98,UL1087
UL508
UL508
UL508
UL489
UL508
UL508
UL489
UL508
UL508
UL508
UL508
UL508
Component funciton per NEC
Disconnect
X
X
X
X
X
X
Branch circuit
protection
X
X
X
X
X
X
Motor control
X
X
X
X
X
X
Motor overload
X
X
X
X
X
X
78
Appendix
Appendix 2 : Short circuit coordination comparison
UL508 (Part IV, Combination Motor Controllers) and IEC60947-4-1 are the two major standards concerning the combination of
the MMS and the Contactor. In IEC60947-4-1, it only regulates the short-circuit protective coordination between the Contactor
and the Circuit Breaker. However, in UL508, it takes the combination of the MMS and Contactor as a united component and
requires additional performances besides the short-circuit test.
UL standard is available for another standard related short circuit coordination, that is UL subject 508E.
(IEC type "2" Coordination Short Circuit Tests of Electromagnetic Motor Controllers in accordance with IEC Publication 947-4-1)
UL subject 508E is to certify that the coordination between the MMS and Contactor comply with IEC60947-4-1 type 2
requirements.
Fuji combination Starters are also cUL listed UL subject 508E, which means that it comforms to both UL and IEC regulation for
short-circuit coordination.
Coordination details between MMS and Contactor as UL508 Type F, please see page 56, 57, as UL subject 508E, please see
page 79, 80.
Test
Short-Circuit 
Coordination
Current withstand
Dielectric voltage withstand
Calibration
Temperature
Effective region
UL508
Type F
X
X
X
X
X
North America
IEC60947-4-1
Type 1 Type 2
UL subject 508E
- The contactor may be damaged
- It may not be suitable for further
service without repair or
replacement.
X
-
X
-
-
Europe
- The contactor may be damaged
- It may not be suitable for further
service without repair or
replacement.
X
-
X
X
-
Europe
- No damage except light welding
of the contacts of the contactor.
- It shall be suitable for further use.
X
-
X
X
-
North America
- No damage except light welding
of the contacts of the contactor.
- It shall be suitable for further use.
79
Appendix
• BM3RSB, BM3RHB (UL subject E coordination)
220-240V AC 440-480V AC
-
-
-
-
-
-
1/2
3/4
1-1/2
3
3
5
5
7-1/2
10
-
-
-
-
-
-
2.2
3.2
6
9.6
9.6
15.2
15.2
22
28
-
-
-
-
-
3/4
1
2
3
5
7-1/2
10
10
15
20
-
-
-
-
-
1.6
2.1
3.4
4.8
7.6
11
14
14
21
27
BM3RSB-P16
BM3RSB-P25
BM3RSB-P40
BM3RSB-P63
BM3RSB-001
BM3RSB-1P6
BM3RSB-2P5
BM3RSB-004
BM3RSB-6P3
-
-
-
-
-
-
BM3RHB-P16
BM3RHB-P25
BM3RHB-P40
BM3RHB-P63
BM3RHB-001
BM3RHB-1P6
BM3RHB-2P5
BM3RHB-004
BM3RHB-6P3
BM3RHB-010
BM3RHB-013
BM3RHB-016
BM3RHB-020
BM3RHB-025
BM3RHB-032
BZ0LRC09AA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRC09AA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRC09AA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRC09AA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRC09AA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRC09AA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRC09AA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRE22AA
BZ0LRE22GA
BZ0LRE32AA
BZ0LRE32GA
BZ0LRE32AA
BZ0LRE32GA
-
BZ0BPRE22A
BZ0BPRE22A
-
BZ0BPRE22A
BZ0BPRE22A
-
BZ0BPRE22A
BZ0BPRE22A
-
BZ0BPRE22A
BZ0BPRE22A
-
BZ0BPRE22A
BZ0BPRE22A
-
BZ0BPRE22A
BZ0BPRE22A
-
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE22A
BZ0BPRE32A
BZ0BPRE22A
BZ0BPRE32A
BZ0BPRE22A
50
50
50
50
50
50
50
50
50
-
-
-
-
-
-
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
SC-M01, M01/G
SC-E02
SC-E02/G
SC-M01, M01/G
SC-E02
SC-E02/G
SC-M01, M01/G
SC-E02
SC-E02/G
SC-M01, M01/G
SC-E02
SC-E02/G
SC-M01, M01/G
SC-E02
SC-E02/G
SC-M01, M01/G
SC-E02
SC-E02/G
SC-M01, M01/G
SC-E02
SC-E02/G
SC-E02
SC-E02/G
SC-E04
SC-E04/G
SC-E04
SC-E04/G
SC-E05
SC-E05/G
SC-E05
SC-E05/G
SC-E05
SC-E05/G
SC-E1
SC-E1/G
SC-E1
SC-E1/G
MMS part number Contactor 
part number
Link module
Short-circuit ratings at
480V AC (kA)
Base plate
HP rating
(HP)
Rated
current (A)
HP rating
(HP)
Rated
current (A)
Part number
0.1-0.16
0.16-0.25
0.25-0.4
0.4-0.63
0.63-1
1-1.6
1.6-2.5
2.5-4
4-6.3
6.3-10
10-13
11-16
14-20
18-25
24-32
Current
range (A)
for BM3RSB for BM3RHB
80
Appendix
• BM3VSB, BM3VHB (UL subject E coordination)
220-240V AC 440-480V AC
3
3
5
5
7-1/2
10
10
9.6
9.6
15.2
15.2
22
28
28
5
7-1/2
10
10
15
20
30
7.6
11
14
14
21
27
40
BM3VSB-010
BM3VSB-013
BM3VSB-016
BM3VSB-020
BM3VSB-025
BM3VSB-032
BM3VSB-040
BM3VHB-010
BM3VHB-013
BM3VHB-016
BM3VHB-020
BM3VHB-025
BM3VHB-032
BM3VHB-040
BZ0LVE51AA
BZ0LVE51GA
BZ0LVE51AA
BZ0LVE51GA
BZ0LVE51AA
BZ0LVE51GA
BZ0LVE51AA
BZ0LVE51GA
BZ0LVE51AA
BZ0LVE51GA
BZ0LVE51AA
BZ0LVE51GA
BZ0LVE51AA
BZ0LVE51GA
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
BZ0BPVE51A
25
25
25
25
25
25
25
50
50
50
50
50
50
50
SC-E1
SC-E1/G
SC-E1
SC-E1/G
SC-E1
SC-E1/G
SC-E1
SC-E1/G
SC-E1
SC-E1/G
SC-E1
SC-E1/G
SC-E2
SC-E2/G
MMS part number Contactor 
part number
Link module
Short-circuit ratings at
480V AC (kA)
Base plate
HP rating
(HP)
Rated
current (A)
HP rating
(HP)
Rated
current (A)
Part number
6.3-10
10-13
11-16
14-20
18-25
24-32
28-40
Current
range (A)
for BM3VSB for BM3VHB
81
TERMS AND CONDITIONS OF SALE
Prices
All prices are subject to change without notice. In the
event of a price change, the effective date of the
change will be the date on the new price or discount
schedule sheet.
All quotations made or orders accepted after the
effective date will be based on the new prices.
Quotations
Written quotations are valid for 30 days from its date
unless otherwise stated in the quotation. Verbal
quotations expire the same day they are made.
Taxes
The price does not include any taxes. Buyer shall be
responsible for the payment of all applicable taxes.
Terms of payment
Terms of payment will be listed on the quotations.
Minimum orders
Orders amounting to less than $150.00 net per order
will be charged a $50.00 handling fee.
Delivery
Delivery of products shall be FOB point of origin in the
U.S. Seller shall determine the point of origin of
shipment. All shipping and other charges shall be paid
by Buyer.
Packing
Prices include standard domestic packing. Additional
special packing costs required for export or by Buyer's
request will be charged to Buyer.
Weight and Dimensions
The weight and dimensions of products described in
this catalog are the best information available at the
time of going to press. As Seller follows a policy of
continuous product improvement, design changes may
make this information obsolete. Information in this
catalog is subject to change without notice.
Inspection and acceptance of products
Buyer is responsible for evaluating received products
for final acceptance. All claims for shortage must be
made within thirty (30) days of receipt of products.
Return / Cancellation
No product shall be returned or canceled unless
return/order cancel authorization has been secured
from Seller. All returns/cancellations must comply with
Seller's then current Return / Cancellation policy.
Risk of Loss
Risk of loss or damage to the product shall pass to
Buyer at the FOB point.
Catalog Disclaimer
The information contained in this catalog does not
constitute an express or implied warranty of quality,
any warranty of merchantability of fitness for a
particular purpose is hereby disclaimed.
Since the Buyer's product information, specific use
application, and conditions of use are all outside of
Seller's control, it shall be the responsibility of the
Buyer to determine the suitability of any of the
products mentioned for the Buyer's application.
82
The products identified in this catalog shall be sold pursuant
to the terms and conditions identified in the Conditions of
Sale issued by Fuji Electric with each order confirmation.
Except to the extent otherwise provided for in the
Conditions of Sale issued by Fuji Electric, Fuji Electric
warrants that the Fuji Electric products identified in this
catalog shall be free from significant defects in materials
and workmanship provided the products have not been: (1)
repaired or altered by others than Fuji Electric; (2) subjected
to negligence, accident, misuse, or damage by
circumstances beyond Fuji Electric's control; (3) improperly
operated, maintained or stored; or (4) used in other than
normal use or service. This warranty shall apply only to
defects appearing within one (1) year from the date of
shipment by Fuji Electric, and in such case, only if such
defects are reported to Fuji Electric within thirty (30) days of
discovery by purchaser.
Such notice should be submitted in writing to Fuji Electric at
Park 80 West, Plaza II, Saddle Brook, NJ 07663. The sole and
exclusive remedy with respect to the above warranty
whether such claim is based on warranty, contract,
negligence, strict liability or any other theory, is limited to
the repair or replacement of such product or, at Fuji
Electric's option, reimbursement by Fuji Electric of the
purchase price paid to Fuji Electric for the particular product.
FUJI ELECTRIC DOES NOT MAKE ANY OTHER
REPRESENTATIONS OR WARRANTIES, WHETHER ORAL OR
IN WRITING, EXPRESSED OR IMPLIED, INCLUDING BUT
NOT LIMITED TO ANY WARRANTY REGARDING
MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE.
Except as provided in the Conditions of Sale, no agent or
representative of Fuji Electric is authorized
to modify the
terms of this Warranty in writing or orally.
In no event shall Fuji Electric be liable for special, indirect or
consequential damages, including but not limited to, loss of
use of the product, other equipment, plant, power system,
loss of profits or revenues, cost of capital, or claims against
the purchaser or user by its customers resulting from the
use of information, recommendations and descriptions
contained herein. Purchaser agrees to pass on to its
customers and users, in writing at the time inquiries and
orders are received by buyer, Fuji Electric's warranty as set
forth above.
ONE YEAR LIMITED WARRANTY
INFORMATION IN THIS CATALOG IS SUBJECT TO CHANGE WITHOUT NOTICE.
Printed in USA 2004/5M
FUJI ELECTRIC FA COMPONENTS
& SYSTEMS
Gate City Osaki, East Tower
11-2 Osaki 1-chome
Shinagawa-ku, Tokyo 141-0032, Japan
Phone: Tokyo 3-5435-7136
Fax: Tokyo 3-5435-7457
Website: www.fujielectric.co.jp
FUJI ELECTRIC CORP.
OF AMERICA
Park 80 West Plaza II
Saddle Brook, NJ 07663
Phone: 201-712-0555
Fax: 201-368-8258
Website: www.fujielectric.com
Your local authorized stocking distributor is:
MANUAL MOTOR STARTERS
MAGNETIC CONTACTORS
USEH530a