System User Guide ............................ 2
MFX-2200
Fume Extraction System
www.okinternational.com
OMFX2200 Nov05.doc
2
System User Guide
Safety Warnings ..................................................2
Items supplied .....................................................3
Description ..........................................................3
Installation ...........................................................4
Operation ............................................................4
Maintenance........................................................5
Digital Control......................................................6
Troubleshooting...................................................8
Technical Data.....................................................9
Part Numbers ....................................................10
Warranty ...........................................................10
Contact Information............................................11
Safety Warnings
For safe and successful operation of this equipment, please read this user guide
completely. If the instructions stated herein are not observed or followed, the
manufacturer cannot assume responsibility for any harm or damage to the operator or
equipment. Please retain this manual for future reference.
Always disconnect the power supply before servicing the equipment.
Do not operate this equipment without filter inserts as contaminants in the extracted air
will damage the blower. Use only filters recommended or supplied by OK International.
The MFX-2200 is designed for the removal of fumes and gases only. Consult your
company’s Safety Department when using this equipment for filtering of flammable
gases to ensure that the equipment is adequate for your application. This equipment is
not explosion safe and can only be used for the extraction of vapors that have a
concentration level well below the lower explosive limit.
This equipment is equipped with “automatic reset overload protection” that may restart
the equipment automatically after an overload shutdown.
This equipment is to be repaired only by an authorized OK International Service
Representative while it is under warranty.
OMFX2200 Nov05.doc
3
Items supplied
1 - Filter unit with filters installed
1 - Power cord (110VAC or 230VAC)
1 - User Guide
Description
Parts and Functions
(1) Control panel (with On / Off switch)
(2) Power inlet and circuit breaker
(3) Air inlet - port sizes vary by model number.
(4) Filters
(5) Air outlet
Model Variations
Model Number
Power Supply
Filtration
Control Panel
MFX-2200C-A
MFX-2200C-D
MFX-2200G-A
MFX-2200G-D
110 V, 50/60 Hz
110 V, 50/60 Hz
110 V, 50/60 Hz
110 V, 50/60 Hz
Pre – HEPA - Gas
Pre – HEPA - Gas
Pre – Gas
Pre – Gas
Analog
Digital
Analog
Digital
MFX-2206C-A
MFX-2206C-D
MFX-2206G-A
MFX-2206G-D
230 V, 50 Hz
230 V, 50 Hz
230 V, 50 Hz
230 V, 50 Hz
Pre – HEPA - Gas
Pre – HEPA - Gas
Pre – Gas
Pre – Gas
Analog
Digital
Analog
Digital
Models with Pre / HEPA / Gas filtration:
Supplied with a Pre-filter (1) and a Combination-
filter (HEPA / Gas) (2) - these models are designed
for the removal of solder, laser-, and other fumes
which have a high particulate content.
Models with Pre / Gas filtration:
Supplied with a Pre-filter (1), a high capacity Gas-
filter (2) and an After-filter (3) - these models are
designed for the absorption of gases and the
removal of odors.
For use on “flammable” gases refer to “Safety Warnings” above.
2
1
2
3
3
4
2
5
1
OMFX2200 Nov05.doc
4
Installation
Set-Up
Position equipment in the work area and make sure there is ample access to
the unit for filter maintenance.
Connect extraction hoses to the air inlets.
Connect the power cord to the equipment and to a grounded wall socket.
Follow operating and maintenance procedures stated in this user guide.
Operation
Do not operate the equipment without installing filters. Unfiltered air
contaminants may damage motor bearings and other components. Use only factory
recommended filters.
Models with Analog Control
Toggle switch (1) to turn the unit
ON / OFF
Monitor the gauge (2) for filter
condition
Models with Digital Control
Display Functions:
(1) Start / Stop
(2) Operation Indicator Light
o Green: Unit is on. No alert.
o Blinking Green – Orange: Pre-
Alarm is On
o Blinking Green – Red: Alarm is
On
o Blinking Red: Pump is OFF /
Alarm is On / Auto-shut-down
is ON.
(3) Particulate Filter Condition – blockage in %
(4) Exhaust Air Temperature
(5) Setup Button
(6) Time to Service
(7) Actual Run Time
(8) Particulate Filter Condition – Bar Graph
(9) Quick View Button of Set Parameters
All alarms are “visual”. No acoustical alarms. In an alarm condition one or several
LCDs (3) (4) (6) or (7) will be blinking to indicate which alarm flag is ON.
Press (1) to turn the equipment ON / OFF
Monitor the following parameters
o LED (2) for any ALERT conditions.
o Particulate filter condition (3) and (8) for any alarm condition
1
2
3
5
6
8
7
9
4
1
2
OMFX2200 Nov05.doc
5
o Temperature (4). Unit will turn off when exceeding 80C or 175F.
o Time to Service. The alarm setting may have been turned ON.
o Actual run time. A specific run time may have been set and the alarm
turned ON.
Press (9) to view programmed settings for (4)Temperature, (6)Time-to-Service
and (7) Run Time.
For additional information and programming steps please refer to Section “Digital
Control” in this manual.
This equipment is equipped with “automatic reset overload protection” that may
restart the equipment automatically after an overload shutdown.
Maintenance
Filter Replacement Timing
Models with Pre / HEPA / Carbon filters
When (a) the gauge needle falls into the red marked field (analog units), or (b) when
the LED of the Bar Graph turns red (digital units), it is time to change filters. Change
pre-filter first. If the needle of the analog gauge remains near to the “red” mark
(analog units), or the LED of the particulate-filter monitor remains orange or red
(digital units), also replace the HEPA filter.
Models with Pre / Gas filters
When odor is noticeable in the exhaust air, change the pre-filter and gas-filter
simultaneously.
Filter Replacement Procedure
Turn equipment off and disconnect the power cord from the wall socket
Unlatch the filter unit lid
Remove the lid
Replace filters
Place lid back on and close the latches
Turn equipment on
Always use new replacement filters from the original manufacturer!
Filter Disposal
Keep “used” filters in disposable bags or closed containers to avoid contamination of
other areas. While the filter material is none-hazardous, the contaminants captured
inside the filter may be hazardous. Please consult the MSDS Sheets for the material
used at your facility and follow the prescribed handling instructions. Follow your local
regulations for disposal of used filters.
OMFX2200 Nov05.doc
6
Digital Control
Features:
Displays all critical system
parameters
Alerts when critical conditions exist
Allows quick-view of programmed
settings
Reset of factory default settings
possible
Programmable auto-shut-down
(ASD) except for temperature
Display Functions
Description
Factory
Default
(1)
Start / Stop
Turns unit On and Off
N/A
(2)
Operation Indicator Light
o Green: Unit is on. No alert.
o Blinking “Green – Orange”:
Pre-Alarm is ON
o Blinking “Green – Red”:
Alarm is On
o Blinking “Red”: Pump is
OFF / Alarm is ON / Auto-
shut-down is ON.
Color of indicator light displays
operating condition of unit. If an
alarm has been triggered, the critical
system parameter will blink on the
display.
N/A
(3)
Particulate Filter Condition
blockage in %
Measures the differential pressure
across the filters and compares the
value against a factory-set value.
Change filters if factory-set value is
reached
ASD =
OFF
(4)
Exhaust Air Temperature
Protects the equipment against
over-heating due to very hot
incoming air. The operation indicator
light (2) will display an ALERT at
70C (158F) and turns unit off, if
temperature exceeds 80C (175F).
ASD = ON
(5)
Setup Button – Used to
program alarm conditions and
values.
Used for programming of Set-
Values and turning Alarm feature
ON/OFF in programming mode.
N/A
(6)
Time to Service
This feature allows scheduling of
mandatory service if required.
When unit is commissioned, the
Time-to-Service is reset to 365
days. Every calendar day (not 24
hrs operating time), the Time-to-
Service is reduced by 1 day.
ASD =
OFF
1
2
3
5
6
8
7
9
4
OMFX2200 Nov05.doc
7
Display Functions
Description
Factory
Default
(7)
Actual Run Time
Displays the accumulated operating
time. Can also be used as an alarm
when setting a specific run time in
Set-Up mode and turning the alarm
feature to ON.
ASD =
OFF
Run time =
99999
(8)
Particulate Filter Condition
Bar Graph
Displays graphically the particulate
filter condition. If filter is in good
condition, the bar graph color is
green. The color changes with
increasing saturation to yellow and
then red.
Change filters when graph turns red.
N/A
(9)
Quick View Button
Displays Settings for
o Particulate filter condition Auto
Shut-Down
o Temperature readings in C or F
and Auto Shut-Down
o Time-to-Service Auto Shut-
Down
o Run Time max. value and Auto
Shut-Down
N/A
ASD = Auto Shut-Down
All alarms are “visual”. No acoustical alarms.
Setup of Parameters
Program Buttons:
(5) Setup
(1) Up
(9) Down
Steps
Description
Action
Enter Setup mode
Press and hold down <Setup>
for 2 seconds.
Select parameter you
wish to change:
Parameters which can be
changed:
(3) % particulate filter
condition
(4) temperature
(6) time-to-service
(7) run time
Press <Setup> repeatedly until
desired parameter display
blinks.
5
1
2
3
5
6
8
7
9
4
OMFX2200 Nov05.doc
8
Steps
Description
Action
Change Auto Shut-Down to
ON or OFF
Press <Up> to toggle between
ON and OFF.
In blinking mode of:
(3) % Particulate
Filter Condition
No other functions possible.
Auto Shut-Down
Factory set to ON. Not
programmable
In blinking mode of:
(4) Temperature
To switch between Celsius
or Fahrenheit
Press <Down> to toggle
between C and F
Reset to 365 days.
(The value cannot be
changed.)
Press and hold down <Down>
for 2 seconds.
In blinking mode of:
(6) Time-to-Service
Change Auto Shut-Down to
ON or OFF
Press <Up> to toggle between
1 and 0.
Set value for Run Time
Press <Up> or <Down> to
change the value.
Reset Run Time
Press and hold down <Down>
for 2 seconds.
In blinking mode of:
(7) Run Time
Change Auto Shut-Down to
ON or OFF
Press <Up> to toggle between
1 and O.
To exit Setup mode
Press and hold down <Setup>
for 2 seconds.
Troubleshooting
Problem
Possible Cause
Check and Correction
Equipment does
not turn on
No power
Check ON / OFF switch
Check power cord connections and integrity
Check circuit breaker (at rear of unit)
Check “Automatic Shut-Down” functions on units
with digital control
Air leak
Check lid for properly closure and latching
Minimum air
flow
Air blockage
Check extraction hose for any blockage
Check filter monitor for filter saturation
OMFX2200 Nov05.doc
9
Technical Data
* Notice: The noise level is approximately only and varies with number of exhaust
arms connected or amount of airflow.
Models MFX-2200C-A (analog) MFX-2206C-A (analog)
MFX-2200C-D (digital) MFX-2206C-D (digital)
110V 230V
Air inlet openings 4 x Ø2.5” 4 x Ø63mm
Fan capacity 600 cfm 900 m3/h
Flow Rate 400 cfm 600 m3/h
Max. Static Pressure 4.5” WC 1075 Pa
HEPA efficiency 99.97% at 0.3mic 99.97% at 0.3mic
Power supply 100-120VAC, 60 Hz 220 – 240VAC, 50Hz
Power 400 Watt 400 Watt
Noise level, approx.* 58 dBA 58 dBA
Dimensions (W/D/H mm) 17.7”x20.75”x26.4” 450x525x670mm
Weight, approx. 93 lbs 43 kg
Certification UL, CSA CE
Models MFX-2200G-A (analog) MFX-2206G-A (analog)
MFX-2200G-D (digital) MFX-2206G-D (digital)
110V 230V
Air inlet openings 2 x Ø4” and 2 x Ø2.5” 2xØ100mm and 2xØ63mm
Fan capacity 600 cfm 900 m3/h
Flow Rate 350 cfm 550 m3/h
Max. Static Pressure 4.5” WC 1075 Pa
Power supply 100-120VAC, 60 Hz 220 – 240VAC, 50Hz
Power 400 Watt 400 Watt
Noise level, approx.* 58 dBA 58 dBA
Dimensions (W/D/Hmm) 17.7”x20.75”x28” 450x525x710mm
Weight, approx. 115 lbs 52 kg
Certification UL, CSA CE
OMFX2200 Nov05.doc
10
Part Numbers
Filter Units
MFX-2200C-A Filter Unit Analog P/H/G 400 cfm 110VAC/ 60Hz
MFX-2200G-A Filter Unit Analog P/G 350 cfm 110VAC/ 60Hz
MFX-2200C-D Filter Unit Digital P/H/G 400 cfm 110VAC/ 60Hz
MFX-2200G-D Filter Unit Digital P/G 350 cfm 110VAC/ 60Hz
MFX-2206C-A Filter Unit Analog P/H/G 600m3/h 230VAC/ 50Hz
MFX-2200G-A Filter Unit Analog P/G 550m3/h 230VAC/ 50Hz
MFX-2206C-D Filter Unit Digital P/H/G 600m3/h 230VAC/ 50Hz
MFX-2200G-D Filter Unit Digital P/G 550m3/h 230VAC/ 50Hz
Options
AC2202 Top Cover Kit with 4 air inlets Ø 2.5”
AC2204 Top Cover Kit with two 4” and two 2.5” air inlets
Replacement Filters
For “Pre / HEPA / Gas” Models
Fil22P030 Pre-filter Pleated 60% efficiency 2-pack
Fil22H070 Combination Filter HEPA / Carbon
For “Pre / Gas” Models
Fil22P040 Pre-filter Pleated 85% efficiency
Fil22G010 Gas Filter Cartridge 11kg (25lbs)
Fil22G020 Carbon Refill Kit 11kg (25lbs)
Warranty
OK International warrants the MFX-2200 Series against any defects in materials or
workmanship for one (1) year from the date of purchase by the original owner. This
warranty excludes normal maintenance and shall not apply to any opened, misused,
abused, altered or damaged items. If the product should become defective within the
warranty period, OK International will repair or replace it free of charge at its sole
option. The repaired or replacement item(s) will be shipped, freight prepaid, to the
original purchaser. The warranty period will start from the date of purchase. If the date
of purchase cannot be substantiated the date of manufacture will be used as the start
of the warranty period.
For repair or return of the equipment anytime, a Return Material Authorization Number
(RMA #) from OK International is required.
OMFX2200 Nov05.doc
11
Contact Information
For Sales and Customer Care
North America
OK International
12151 Monarch Street
Garden Grove, CA 92841
USA
Tel: +1 714-799-9910
Fax: +1 714-799-9533
United Kingdom
OK International Ltd.
Eagle Close, Chandlers Ford
Hampshire, SO53 4NF
U.K.
Tel: +44 (0) 23 8048 9100
Fax: +44 (0) 23 8048 9109
France
OK International SA
Rue de la Saone
Zac De Folliouses-Les Echets
01706 Miribel Cedex
France
Tel: +33 (0) 4 72 26 20 30
Fax: +33 (0) 4 72 26 20 35
China
OK Electronics (Beijing) Co., Ltd
No. 1 Bldi, A-10 Long Qing Street
Beijing Econ. & Tech. Develop. Zone
Beijing, 100176
P.R. China
Tel: +86-10-67878490
Fax: +86-10-67878491
Germany
OK International GmbH
Frankfurter Strasse 74
D-64521 Gross-Gerau
Germany
Tel: +49 (0) 61 52-71 12-0
Fax: +49 (0) 61 52-71 12-22
Japan
OK International Japan Co.
5-3-1 Heiwajima, Ota-ku
Tokyo 143-0006
Japan
Tel: +81-3-5753-0085
Fax: +81-3-3765-8855
Italy
OK International
Strada Statale 11 – No. 28,
20010 Vittuone (Milano)
Italy
Tel: +39 02 9025161
Fax: +39 02 90111147
Singapore
OK International (Sales Support Office)
10 Ang Mo Kio St.65
#03-18/19 Techpoint
Singapore 569059
Tel: +65-62810991
Fax: +65-62853473