AC centrifugal fans - RadiCal(R) Series R2E190 RA O190 mm 230 50/60 RPM oC g Yes 70 2,450 -25...75 1,200 IP44 6 Yes Yes 70 2,500 -25...75 1,200 IP44 1.5 Yes UL 347.3 Watts Capacitor 50/60 Ingress Protection Rating 115 Mass 341.4 Temperature range (1) R2E190-RA50-21 R2E190-RA26-20 Speed (1) VAC Power input CFM Ball bearings Nominal voltage Type Nominal Data Hertz Air flow Highlights: - Backward curved - 7-blade impeller, single phase motor - Thermal overload protector (TOP) wired internally - Mounting position: Any - Condensate discharge holes: None - Ingress protection of IP44; dependent on installation and position Material: Fiberglass reinforced composite Impeller: PA Direction of rotation: Clockwise, seen on rotor F (1) Nominal data at operating point with maximum load. Curves R2E190-RA50-21 Curves Pe rpm W (115V) dB(A) Druck p f s[Pa]fur Rho=1,2kg/m^3 50 100 150 qv[cfm] 200 250 300 350 460 440 420 400 380 360 340 320 4 300 280 pf s[Pa] 260 240 220 3 200 180 160 140 120 2 100 80 60 40 0 a] s[P pf 20 1 0 50 100 150 200 250 300 350 qv[m^3/h] 400 450 500 550 600 1,85 1,8 1,75 1,7 1,65 1,6 1,55 1,5 1,45 1,4 1,35 1,3 1,25 1,2 1,15 1,1 1,05 1 0,95 0,9 0,85 0,8 0,75 0,7 0,65 0,6 0,55 0,5 0,45 0,4 0,35 0,3 0,25 0,2 0,15 0,1 0,05 0 Measurement: LU-128367 p fs_E[IN H2O] 0 I A n LwA A 1 2750 60 0.53 68 Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. A 2 2575 63 0.55 64 A 3 2450 66 0.59 60 A 4 2630 62 0.54 65 Suction-side noise levels: LWA as per ISO 13347, LPA measured at 1m distance to fan axis. A 5 A 6 A 7 The values given are valid under the measuring conditions mentioned and may vary accoring to the actual installation situation. A 8 With any deviation to the standard set-up, the specific values have to be checked and reviewed once installed or fitted. For detailed information on the measuring set-up, please contact ebm-papst. A 9 A 10 A 11 A 12 A 13 A 14 A 15 A 16 R2E190-RA26-20 Curves Druck p f s[Pa]fur Rho=1,2kg/m^3 50 100 150 qv[cfm] 200 250 300 350 480 460 440 420 400 380 360 340 320 4 300 pfs[Pa] 280 260 240 3 220 200 180 160 140 2 120 100 80 60 40 0 ] [Pa pfs 20 1 0 50 100 150 200 250 300 350 qv[m^3/h] 400 450 500 550 600 1,95 1,9 1,85 1,8 1,75 1,7 1,65 1,6 1,55 1,5 1,45 1,4 1,35 1,3 1,25 1,2 1,15 1,1 1,05 1 0,95 0,9 0,85 0,8 0,75 0,7 0,65 0,6 0,55 0,5 0,45 0,4 0,35 0,3 0,25 0,2 0,15 0,1 0,05 0 650 p fs_E[IN H2O] 0 Pe rpm W (230V) dB(A) A B 1 2720 60 0.27 68 Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. A B 2 2635 62 0.27 65 A B 3 2500 65 0.29 61 A B 4 2670 61 0.27 66 Suction-side noise levels: LWA as per ISO 13347, LPA measured at 1m distance to fan axis. A 5 A 6 A 7 The values given are valid under the measuring conditions mentioned and may vary accoring to the actual installation situation. A 8 With any deviation to the standard set-up, the specific values have to be checked and reviewed once installed or fitted. For detailed information on the measuring set-up, please contact ebm-papst. A 9 A 10 A 11 A 12 A 13 A 14 A 15 A 16 2.66 (68.5) 2.46 (62.5) 0.55 (14) O2.28 (58+0.2) Depth of screw max. 5mm 0.24 (6) 3.35 (85 +10) O0.2(4.5) 4X 17.72 (450 +20) O6.22 (158) O6.69 (170) O4.94 (125.5) O5.20 (132.2) O7.48 (190) O3.15 (80) O1.06(27+0.1) 0.05(1.25) Accessory part: Inlet nozzle 09576-2-4013, not included in the standard scope of delivery Connection line PVC 4G 0.5mm2, 4x brass lead tips crimped 0.08 (2) LwA Measurement: LU-125753 R2E190-RAXX-XX 0.08 (2) I A n A 1 A 2 A 3 A 4 A 5 A 6 A 7 A 8 A 9 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: ebm-papst: R2E190-RA50-21 R2E190-RA26-20 R2E190-AO26-24 R2E190-AO26-57 R2E190-AP88-14 R2E190-AO26-44 R2E190-AO50-17 R2E190-AO84-22 R2E190-AE50-92 R2E190-AO50-43 R2E190-AO26-64 R2E190-AO26-26 R2E190-AO50-96 R2E190-AO26-67 R2E190-AO50-95 R2E190-AO26-52 R2E190-RA26-46