GU SOP 2 Form A (AQW21S) TESTING Miniature SOP8-pin type of 60V/350V/400V load voltage 4.4 .173 2.1 .083 9.37 .369 mm inch 1 8 2 7 3 6 4 5 RoHS compliant GU SOP 2 Form A (AQW21S) FEATURES TYPICAL APPLICATIONS 1. 2 channels in miniature SOP8-pin design The device comes in a super-miniature SO package measuring (W) 4.4 x (L) 9.37 x (H) 2.1 mm (W) .173x (L) .369x (H) .083 inch --approx. 38% of the volume and 66% of the footprint size of DIP8-pin type. 2. Controls low-level analog signals PhotoMOS feature extremely low closedcircuit offset voltage to enable control of low-level analog signals without distortion. 3. Low-level off state leakage current of max. 1 A * Measuring instruments * Data communications * Computers * Industrial robots * High-speed inspection machines. TYPES Output rating* Load voltage Part No. Load current New 60V 400mA 350V 100mA 400V 80mA AC/DC dual use Package SOP8-pin Packing quantity Tape and reel packing style Picked from the Picked from the 1/2/3/4-pin side 5/6/7/8-pin side Tube packing style AQW212S AQW212SX AQW212SZ AQW210S AQW210SX AQW210SZ AQW214S AQW214SX AQW214SZ Tube Tape and reel 1 tube contains: 50 pcs. 1 batch contains: 1,000 pcs. 1,000 pcs. * Indicate the peak AC and DC values. Note: The packing style indicator "X" or "Z" are not marked on the device. RATING 1. Absolute maximum ratings (Ambient temperature: 25C 77F) Input Output Item LED forward current LED reverse voltage Peak forward current Power dissipation Load voltage (peak AC) Symbol IF VR IFP Pin VL AQW212S Continuous load current Peak load current Power dissipation Total power dissipation I/O isolation voltage Temperature limits ASCTB141E 201201-T Operating Storage AQW214S 60 V AQW210S 50 mA 5V 1A 75 mW 350 V IL 0.4 A (0.5 A) 0.1 A (0.13 A) 0.08 A (0.1 A) Ipeak Pout PT Viso Topr Tstg 1.5 A Panasonic Corporation Remarks f = 100 Hz, Duty factor = 0.1% 400 V 0.3 A 0.24 A 600 mW 650 mW 1,500 V AC -40C to +85C -40F to +185F -40C to +100C -40F to +212F Automation Controls Business Unit Peak AC, DC ( ): in case of using only 1 channel A connection: 100 ms (1 shot), VL = DC Non-condensing at low temperatures industrial.panasonic.com/ac/e GU SOP 2 Form A (AQW21S) 2. Electrical characteristics (Ambient temperature: 25C 77F) Item Symbol Typical Maximum Minimum Typical Typical Maximum LED operate current Input LED turn off current LED dropout voltage AQW212S IFon IFoff VF Typical On resistance Ron Maximum Output Off state leakage current Maximum Typical Maximum Typical Maximum Typical Maximum Minimum Turn on time* Transfer characteristics Turn off time* I/O capacitance Initial I/O isolation resistance AQW210S AQW214S 0.9 mA 3 mA 0.4 mA 0.8 mA 1.25 V (1.14 V at IF = 5 mA) 1.5 V 0.83 16 30 2.5 35 50 0.65 ms 0.23 ms Remarks IL = Max. IL = Max. IF = 50 mA IF = 5 mA IL = Max. Within 1 s on time IF = 0 mA VL = Max. 1 A ILeak Ton 2 ms 0.08 ms Toff 0.21 ms IF = 5 mA IL = Max. 0.5 ms 0.04 ms IF = 5 mA IL = Max. 0.2 ms 0.8 pF Ciso f = 1 MHz VB = 0 V 1.5 pF 1,000 M Riso 500 V DC *Turn on/ Turn off time Input 90% Output 10% Toff Ton RECOMMENDED OPERATING CONDITIONS Please obey the following conditions to ensure proper device operation and resetting. Item Input LED current Symbol IF Recommended value Unit 5 mA For Dimensions. For Schematic and Wiring Diagrams. For Cautions for Use. These products are not designed for automotive use. If you are considering to use these products for automotive applications, please contact your local Panasonic Corporation technical representative. For more information. REFERENCE DATA 1.-(1) Load current vs. ambient temperature characteristics 1.-(2) Load current vs. ambient temperature characteristics 2.-(1) On resistance vs. ambient temperature characteristics Allowable ambient temperature: -40C to +85C -40F to +185F When using 2 channels Allowable ambient temperature: -40C to +85C -40F to +185F When using 2 channels Measured portion: between terminals 5 and 6, 7 and 8; LED current: 5 mA; Load voltage: Max. (DC); Continuous load current: Max. (DC) 1.0 5 Load current, A Load current, A 0.6 0.4 AQW212S 100 80 On resistance, 120 0.8 AQW210S AQW214S 60 4 3 2 40 AQW212S 0.2 1 20 0 -40 -20 0 20 40 60 8085 100 Ambient temperature, C Panasonic Corporation 0 -40 -20 0 20 40 60 8085 100 0 -40 -20 Ambient temperature, C Automation Controls Business Unit industrial.panasonic.com/ac/e 0 20 40 60 8085 Ambient temperature, C ASCTB141E 201201-T GU SOP 2 Form A (AQW21S) 2.-(2) On resistance vs. ambient temperature characteristics 3. Turn on time vs. ambient temperature characteristics 4. Turn off time vs. ambient temperature characteristics Measured portion: between terminals 5 and 6, 7 and 8; LED current: 5 mA; Load voltage: Max. (DC); Continuous load current: Max. (DC) LED current: 5 mA; Load voltage: Max. (DC); Continuous load current: Max. (DC) LED current: 5 mA; Load voltage: Max. (DC); Continuous load current: Max. (DC) 50 1.4 0.4 30 AQW210S 20 1.0 0.8 AQW210S 0.6 Turn off time, ms 1.2 AQW214S 40 Turn on time, ms On resistance, AQW212S 0.3 0.2 AQW214S 0.4 AQW212S AQW214S 0.1 10 0.2 0 -40 -20 0 20 40 60 0 8085 AQW210S -40 -20 0 20 40 60 0 8085 -40 -20 Ambient temperature, C Ambient temperature, C 0 20 40 60 5. LED operate current vs. ambient temperature characteristics 6. LED turn off current vs. ambient temperature characteristics 7. LED dropout voltage vs. ambient temperature characteristics Sample: All types; Load voltage: Max. (DC); Continuous load current: Max. (DC) Sample: All types; Load voltage: Max. (DC); Continuous load current: Max. (DC) Sample: All types; LED current: 5 to 50 mA 5 4 3 2 1 1.5 LED dropout voltage, V LED turn off current, mA LED operate current, mA 5 8085 Ambient temperature, C 4 3 2 1.4 1.3 50mA 1.2 30mA 20mA 1.1 10mA 5mA 1 1.0 0 -40 -20 0 20 40 60 0 8085 -40 -20 0 20 40 60 0 80 85 -40 -20 Ambient temperature, C Ambient temperature, C 0 20 40 60 8085 Ambient temperature, C 8.-(1) Current vs. voltage characteristics of output at MOS portion 8.-(2) Current vs. voltage characteristics of output at MOS portion 9. Off state leakage current vs. load voltage characteristics Measured portion: between terminals 5 and 6, 7 and 8; Ambient temperature: 25C 77F Measured portion: between terminals 5 and 6, 7 and 8; Ambient temperature: 25C 77F Measured portion: between terminals 5 and 6, 7 and 8; Ambient temperature: 25C 77F 0.4 AQW212S 0.3 0.2 0.1 -1.0 -0.8 -0.6 -0.4 -0.2 AQW210S 100 80 AQW214S 60 40 20 -5 -4 -3 -2 -1 1 2 3 4 5 -20 Voltage, V -40 0.2 0.4 0.6 0.8 1.0 -0.1 Voltage, V -0.2 -60 -0.3 Off state leakage current, A Current, mA Current, A 0.5 10-3 10-6 10-9 AQW212S AQW210S -80 -0.4 AQW214S -12 10 -100 -0.5 0 20 40 60 80 100 Load voltage, V 10. Turn on time vs. LED forward current characteristics 11. Turn off time vs. LED forward current characteristics 12. Output capacitance vs. applied voltage characteristics Measured portion: between terminals 5 and 6, 7 and 8; Load voltage: Max. (DC); Continuous load current: Max. (DC); Ambient temperature: 25C 77F Measured portion: between terminals 5 and 6, 7 and 8; Load voltage: Max. (DC); Continuous load current: Max. (DC); Ambient temperature: 25C 77F Measured portion: between terminals 5 and 6, 7 and 8; Frequency: 1 MHz; Ambient temperature: 25C 77F 1.4 AQW212S 0.8 0.6 90 AQW214S 0.4 0.10 Output capacitance, pF 1.0 100 0.12 Turn off time, ms Turn on time, ms 1.2 0.14 AQW210S AQW212S 0.08 0.06 AQW214S 0.04 80 70 60 50 40 30 AQW212S AQW210S 20 0.2 0.02 0 0 10 20 30 40 50 60 LED forward current, mA ASCTB141E 201201-T Panasonic Corporation 10 10 20 30 40 50 60 LED forward current, mA Automation Controls Business Unit 0 0 AQW210S, AQW214S 10 20 30 40 Applied voltage, V industrial.panasonic.com/ac/e 50