BS 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2003 TELEDYNE RELAYS
BS\032003\Q1
OUTPUT (LOAD) SPECIFICATION
Min Max Unit
Operating Range
BS24 15 280 Vrms
BS60 24 600 Vrms
Peak V oltage
BS24 600 Vrms
BS60 1200 Vrms
Load Current Range
BS24 .05 4 Arms
BS60 .08 4 Arms
Maximum Surge Current Rating (Non-Repetitive)
(See Figure 5) 100 Apeak
On-State V oltage Drop 1.6 V
Off-State Leakage Current (60Hz) 0.3 mArms
Turn-On Time (60Hz) 8.3 ms
Turn-Off T ime (60Hz) 8.3 ms
Operating Frequency 10 63 Hz
Off-State dv/dt 200 V/µs
Zero-Cross Window
BS24 ±50 V
BS60 ±100 V
I2t for match fusing (<8.3ms)
BS24 50 A2s
BS60 72 A2s
ENVIRONMENTAL SPECIFICATION
Min Max Unit
Operating Temperature –40 80 °C
Storage Temperature –40 150 °C
Input-Output Isolation 4000 Vrms
Input-Output Capacitance 8 pF
NOTES:
1. Electrical specifications at 25°C unless otherwise specified.
2. For 800Hz applications, contact factory.
3. For additional/custom options, contact factory.
Series BS
TYPICAL APPLICATION
LOAD CURRENT DERATING CURVE
SURGE CURRENT RATING
Load Current (Arms)
Ambient Temperature (°C)
Load
L1
N
Load
L1
N
or
external
MOV
external
MOV
Figure 3 – BS relays
Figure 4 – Thermal curves
Figure 5 – Non-repetitive surge current