www.tracopower.com Page 2
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Input Specifications
Input current no load /full load 12 Vin models: 40 mA typ.
24 Vin models: 35 mA typ.
48 Vin models: 25 mA typ.
Input current (full load) 24 V in models: 1000 mA typ.
48 Vin models: 500 mA typ.
Surge voltage 24 Vin models: 50 V max..
(100 msec. max.) 48 Vin models: 100 V max.
Conducted noise (input) EN 55022 level A, FCC part 15, level A
Output Specifications
Voltage set accuracy ± 2 %
Output voltage adjustment ± 10 %
Regulation – Input variation Vin min. to V in max. ± 0.5 % max.
– Load variation 10 – 100 %
– single output models ± 0.5 % max.
– dual output models balanced load ± 3 % max.
– dual output models unbalanced load ± 5 % max.
Ripple and noise (20 MHz Bandwidth) single output models: 75 mVpk-pk max.
dual output models: 100 mVpk-pk max.
Temperature coefficient ± 0.02 % / °C
Output current limitation 105% – 145% of Iout max., foldback
Short circuit protection Indefinite (automatic recovery)
Over voltage protection 5 V out models: 6.2 V
12 V out models: 15 V
15 V out models: 18 V
Capacitive load 5 Vout models /± 5 Vout models: 6’800 µF max. / ± 3’400 µF max.
12 Vout models /±12 Vout models: 2’200 µF max. / ± 680 µF max.
15 V out models / ±15 Vout models: 755 µF max. / ± 450 µF max.
General Specifications
Temperature ranges – Operating – 25 °C ... + 70 °C
– Case temperature + 100 °C max.
– Storage – 55 °C ... + 105 °C
Derating 2.5 %/°C above 60°C
Humidity (non condensing) 95 % rel H max.
Reliability, calculated MTBF (MIL-HDBK-217 E) > 440’000 h @ + 25°C
Isolation voltage – Input/Output 1‘500 VDC
Isolation capacity – Input/Output 300 pF max.
Isolation resistance – Input/Output (500 VDC) > 1‘000 M Ohm
Switching frequency (fixed) 300 kHz typ. (Pulse width modulation PWM)
Remote ON/OFF (optional): ON: 3.5 ... 12 VDC or open circuit.
OFF: 0 ... 1.2 VDC or short circuit pin 4 and pin 2
OFF idle current: 16 mA typ.
DC/DC Conver ter
TEN 20WI Series 20 Watt