Keysight N5700 Series
System DC Power Supplies
Models: N5741A-49A, N5750A-52A, N5761A-69A, N5770A-72A
Data Sheet
2
24 models: 750 W and 1500 W
output power
Up to 600 V and up to 180 A
Small high density 1 U package
Built-in voltage and current mea-
surement
Full protection from over-voltage
and over-current
85-265 Vac universal AC input
Command compatibility for
Sorensen DLM and Xantrex XFR DC
supplies
LAN, USB, and GPIB interfaces
standard
Fully compliant to LXI Class C
specification
The Keysight Technologies, Inc.
N5700 Series system DC power sup-
plies give you just the right perfor-
mance — at just the right price —
in a compact (1 U) package. This
family of affordable 750 W and 1500
W single-output programmable DC
power supplies consists of 24 mod-
els for simple DC power applica-
tions. They provide stable output
power, built-in voltage and current
measurement, and output voltage
and current from 6 V to 600 V and
1.3 A to 180 A.
These economical supplies offer
many system-ready features like
multiple standard I/O interfaces to
simplify and accelerate test-system
development for R&D, design valida-
tion, and manufacturing engineers in
the aerospace/defense, automotive,
component and communications
industries.
Small, high-density package
saves you rack space
The N5700 provides up to 1500 W
in a
small space-saving 1 U-high, 19-inch-
wide package. Its air vents are in
the front, side and rear (not on the
top or bottom), so you can stack
other instruments directly above or
below it to save valuable rack space.
Easy front-panel operation
You can quickly and easily operate
the power supply with its rotary
knobs and buttons. Using the front-
panel controls, you can make coarse
or fine adjustments of output voltage
and current, protection settings, and
set power-on states (last setting
memory or factory default setting).
The output voltage and current are
Family of Affordable Basic System DC Power Supplies
displayed simultaneously, and LED
indicators show power supply status
and operating modes. You can lock
the front panel controls to protect
against accidental power-supply
parameter changes.
Extensive device protection
To safeguard your device from
damage, the N5700 Series power
supplies provide over-temperature,
over-current and over-voltage protec-
tion (OVP) to shut down the power
supply output when a fault condition
occurs. They also offer an under-
voltage limit (UVL) that prevents
adjustment of the output voltage
below a certain limit. The combina-
tion of UVL and OVP capabilities lets
you create a protection window for
sensitive load circuitry.
Simplify system connections
The N5700 Series power supplies
come standard with GPIB, Ethernet/
LAN, and USB 2.0 interfaces giving
you the flexibility to use your I/O
interface of choice today and in the
future. The N5700 is fully compliant
with the LXI Class C specification.
Figure 1. Front-panel control knobs and buttons make it easy
to use N5700 power supplies.
Figure 2. Built-in Ethernet, USB 2.0, and GPIB interfaces enable
easy system connections.
3
Remote access and control
The built-in Web server provides
remote access and control of the
instrument via a standard browser
such as Microsoft Internet Explorer.
Using the Web browser, you can set
up, monitor and operate the N5700
remotely.
Easy system integration and

To simplify system development, the
N5700 comes standard with IVI-COM
drivers. The N5700 supports the easy-
to-use SCPI (Standard Commands for
Programmable Instruments).
Command compatibility
The N5700 includes a compatibility
command set for the Xantrex XFR
series power supplies, the Sorensen
DLM series power supplies, and the
Keysight 603x series power supplies.
This simplifies system integration
when converting to the N5700. For
a comparison of these products, see
application notes:
Side-by-side comparison:
Keysight N5700 Series System DC
Source and Sorensen DLM DC
Power Supply, AN 1502-1,
5989-1628EN
Side-by-side comparison:
Keysight N5700 Series System DC
Source and Xantrex XFR
AN 1502-2, 5989-1630EN

connect multiple units in
parallel and series
Should you need greater output power,
the N5700 series power supplies give
you the flexibility to connect in paral-
lel up to four similarly rated units for
greater output current and connect
two similarly rated units in series for
greater output voltage (see output
terminal isolation information).
Analog programming and
monitoring
The output voltage and current can
be programmed from zero to full scale
by either an analog voltage 0 to 5 V
or 0 to 10 V or by resistances of
0 to 5 kΩ or 0 to 10 kΩ.
Universal AC input
All N5700 models have universal AC
input so they can be automatically
operated from any AC mains input
voltage worldwide. They can be
operated from line voltages of
85 – 265 Vac, 47 to 63 Hz, with no
switch to set or fuses to change
when you switch from one voltage
standard to another. They also
provide power factor correction.
Rack mounting
The rack mount ears and handles
are provided standard with every unit.
In addition the N5740A rack mount
slide kit makes it easy to integrate an
N5700 into a test rack by providing
all the necessary hardware to rack
mount an N5700 series power supply
in only 1 U of rack space.
Figure 3. N5700 series web graphical user interface for remote access and control of the
power supply.
4

Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 40 °C.
N5741A N5742A N5743A N5744A N5745A N5746A
DC output ratings1 Voltage 6 V 8 V 12.5 V 20 V 30 V 40 V
Current 100 A 90 A 60 A 38 A 25 A 19 A
Power 600 W 720 W 750 W 760 W 750 W 760 W
Output ripple and noise CV p-p260 mV 60 mV 60 mV 60 mV 60 mV 60 mV
CV rms38 mV 8 mV 8 mV 8 mV 8 mV 8 mV
Load effect
(change from 10% to 90%)
Voltage 2.6 mV 2.8 mV 3.25 mV 4 mV 5 mV 6 mV
Current 25 mA 23 mA 17 mA 12.6 mA 10 mA 8.8 mA
Source effect
(change from 85-132 VAC input
or 170-265 VAC input)
Voltage 2.6 mV 2.8 mV 3.25 mV 4 mV 5 mV 6 mV
Current 12 mA 11 mA 8 mA 5.8 mA 4.5 mA 3.9 mA
Programming accuracy1Voltage 0.05%+ 3 mV 4 mV 6.25 mV 10 mV 15 mV 20 mV
Current 0.1%+ 100 mA 90 mA 60 mA 38 mA 25 mA 19 mA
Measurement accuracy Voltage 0.1%+ 6 mV 8 mV 12.5 mV 20 mV 30 mV 40 mV
Current 0.1%+ 300 mA 270 mA 180 mA 114 mA 75 mA 57 mA
Load transient recovery time4Time ≤1.5 ms ≤1.5 ms ≤1.5 ms ≤1 ms ≤1 ms ≤1 ms
Supplemental Characteristics Supplemental characteristics are not warranted but are descriptions of typical
performance determined either by design or type testing
Output response time
(settle to within ±1.0% of the
rated output, with a resistive
load)
Up, full load 0.08 s 0.08 s 0.08 s 0.08 s 0.08 s 0.08 s
Down, full load 0.05 s 0.05 s 0.05 s 0.05 s 0.08 s 0.08 s
Down, no load 0.5 s 0.6 s 0.7 s 0.8 s 0.9 s 1.0 s
Command response time555 ms
Data readback transfer time63 ms
Remote sense compensation Volts/load lead 1 V 1 V 1 V 1 V 1.5 V 2 V
Over-voltage protection Range 0.5–7.5 V 0.5–10 V 1–15 V 1–24 V 2–36 V 2–44 V
Accuracy 0.06 V 0.08 V 0.125 V 0.20 V 0.30 V 0.40 V
Output ripple and noise7CC rms 200 mA 180 mA 120 mA 76 mA 63 mA 48 mA
Programming resolution
measurement resolution
Voltage 0.72 mV 0.96 mV 1.5 mV 2.4 mV 3.6 mV 4.8 mV
Current 12 mA 10.8 mA 7.2 mA 4.56 mA 3 mA 2.3 mA
Front panel display accuracy
(4 digits; ±1 count)
Voltage 0.03 V 0.04 V 0.06 V 0.10 V 0.15 V 0.20 V
Current 0.50 A 0.45 A 0.30 A 0.19 A 0.13 A 0.10 A
Notes:
1 Minimum voltage is guaranteed to a maximum of 0.2% of the rated output voltage.
Minimum current is guaranteed to a maximum of 0.4% of the rated output current.
2 Up to 20 MHz
3 From 5 Hz – 1 MHz
4 Time for output voltage to recover within 0.5% of its rated output for a load change from 10 to 90% of its rated output current.
Voltage set point from 10% to 100% of rated output
5 Add this to the output reponse time to obtain the total programming time
6 Time to provide data back to the controller using LAN interface (does not include A/D conversion time)
7 From 5 Hz – 1 MHz, at 10% to 100% of output voltage at full load (for 6 V units from 33% to 100% of output voltage)
5

Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 40°C.
N5747A N5748A N5749A N5750A N5751A N5752A
DC output ratings1 Voltage 60 V 80 V 100 V 150 V 300 V 600 V
Current 12.5 A 9.5 A 7.5 A 5 A 2.5 A 1.3 A
Power 750 W 760 W 750 W 750 W 750 W 780 W
Output ripple and noise CV p-p260 mV 80 mV 80 mV 100 mV 150 mV 300 mV
CV rms38 mV 8 mV 8 mV 12 mV 20 mV 60 mV
Load effect
(change from 10% to 90%)
Voltage 8 mV 10 mV 12 mV 17 mV 32 mV 62 mV
Current 7.5 mA 6.9 mA 6.5 mA 6 mA 5.5 mA 5.26 mA
Source effect
(change from 85-132 VAC input
or 170-265 VAC input)
Voltage 8 mV 10 mV 12 mV 17 mV 32 mV 62 mV
Current 3.25 mA 2.95 mA 2.75 mA 2.5 mA 2.25 mA 2.13 mA
Programming accuracy1Voltage 0.05%+ 30 mV 40 mV 50 mV 75 mV 150 mV 300 mV
Current 0.1%+ 12.5 mA 9.5 mA 7.5 mA 5 mA 2.5 mA 1.3 mA
Measurement accuracy Voltage 0.1%+ 60 mV 80 mV 100 mV 150 mV 300 mV 600 mV
Current 0.1%+ 37.5 mA 28.5 mA 22.5 mA 15 mA 7.5 mA 3.9 mA
Load transient recovery time4Time ≤1 ms ≤1 ms ≤1 ms ≤2 ms ≤2 ms ≤2 ms
Supplemental Characteristics Supplemental characteristics are not warranted but are descriptions of typical
performance determined either by design or type testing
Output response time
(settle to within ±1.0% of the
rated output, with a resistive
load)
Up, full load 0.08 s 0.15 s 0.15 s 0.15 s 0.15 s 0.25 s
Down, full load 0.08 s 0.15 s 0.15 s 0.15 s 0.15 s 0.30 s
Down, no load 1.1 s 1.2 s 1.5 s 2.0 s 3.0 s 4.0 s
Command response time555 ms
Data readback transfer time63 ms
Remote sense compensation Volts/load lead 3 V 4 V 5 V 5 V 5 V 5 V
Over-voltage protection Range 5–66 V 5–88 V 5–110 V 5–165 V 5–330 V 5–660 V
Accuracy 0.60 V 0.80 V 1 V 1.5 V 3 V 6 V
Output ripple and noise7CC rms 38 mA 29 mA 23 mA 18 mA 13 mA 8 m
Programming resolution
measurement resolution
Voltage 7.2 mV 9.6 mV 12 mV 18 mV 36 mV 72 mV
Current 1.5 mA 1.14 mA 0.9 mA 0.6 mA 0.3 mA 0.156 mA
Front panel display accuracy
(4 digits; ±1 count)
Voltage 0.3 V 0.4 V 0.5 V 0.75 V 1.5 V 3 V
Current 0.0625 A 0.0475 A 0.0375 A 0.0250 A 0.0125A 0.0065 A
Notes:
1 Minimum voltage is guaranteed to a maximum of 0.2% of the rated output voltage.
Minimum current is guaranteed to a maximum of 0.4% of the rated output current.
2 Up to 20 MHz
3 From 5 Hz – 1 MHz
4 Time for output voltage to recover within 0.5% of its rated output for a load change from 10 to 90% of its rated output current.
Voltage set point from 10% to 100% of rated output
5 Add this to the output reponse time to obtain the total programming time
6 Time to provide data back to the controller using LAN interface (does not include A/D conversion time)
7 From 5 Hz – 1 MHz, at 10% to 100% of output voltage at full load (for 6 V units from 33% to 100% of output voltage)
6

Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 40°C.
N5761A N5762A N5763A N5764A N5765A N5766A
DC output ratings1 Voltage 6 V 8 V 12.5 V 20 V 30 V 40 V
Current 180 A 165 A 120 A 76 A 50 A 38 A
Power 1080 W 1320 W 1500 W 1520 W 1500 W 1520 W
Output ripple and noise CV p-p260 mV 60 mV 60 mV 60 mV 60 mV 60 mV
CV rms38 mV 8 mV 8 mV 8 mV 8 mV 8 mV
Load effect
(change from 10% to 90%)
Voltage 2.6 mV 2.8 mV 3.25 mV 4 mV 5 mV 6 mV
Current 41 mA 38 mA 29 mA 20.2 mA 15 mA 12.6 mA
Source effect
(change from 85-132 VAC input
or 170-265 VAC input)
Voltage 2.6 mV 2.8 mV 3.25 mV 4 mV 5 mV 6 mV
Current 20 mA 18.5 mA 14 mA 9.6 mA 7 mA 5.8 mA
Programming accuracy1Voltage 0.05%+ 3 mV 4 mV 6.25 mV 10 mV 15 mV 20 mV
Current 0.1%+ 180 mA 165 mA 120 mA 76 mA 50 mA 38 mA
Measurement accuracy Voltage 0.1%+ 6 mV 8 mV 12.5 mV 20 mV 30 mV 40 mV
Current 0.1%+ 540 mA 495 mA 360 mA 228 mA 150 mA 114 mA
Load transient recovery time4Time ≤1.5 ms ≤1.5 ms ≤1.5 ms ≤1 ms ≤1 ms ≤1 ms
Supplemental characteristics Supplemental characteristics are not warranted but are descriptions of typical
performance determined either by design or type testing.
Output response time
(settle to within ±1.0% of the
rated output, with a resistive
load)
Up, full load 0.08 s 0.08 s 0.08 s 0.08 s 0.08 s 0.08 s
Down, full load 0.05 s 0.05 s 0.05 s 0.05 s 0.08 s 0.08 s
Down, no load 0.5 s 0.6 s 0.7 s 0.8 s 0.9 s 1.0 s
Command response time555 ms
Data readback transfer time63 ms
Remote sense compensation Volts/load lead 1 V 1 V 1 V 1 V 1.5 V 2 V
Over-voltage protection Range 0.5–7.5 V 0.5–10 V 1–15 V 1–24 V 2–36 V 2–44 V
Accuracy 0.06 V 0.08 V 0.125 V 0.20 V 0.30 V 0.40 V
Output ripple and noise7CC rms 360 mA 330 mA 240 mA 152 mA 125 mA 95 mA
Programming resolution
measurement resolution
Voltage 0.72 mV 0.96 mV 1.5 mV 2.4 mV 3.6 mV 4.8 mV
Current 21.6 mA 19.8 mA 14.4 mA 9.12 mA 6 mA 4.6 mA
Front panel display accuracy
(4 digits; ±1 count)
Voltage 0.03 V 0.04 V 0.0625 V 0.1 V 0.15 V 0.2 V
Current 0.90 A 0.825 A 0.60 A 0.38 A 0.25 A 0.19 A
Notes:
1 Minimum voltage is guaranteed to a maximum of 0.2% of the rated output voltage.
Minimum current is guaranteed to a maximum of 0.4% of the rated output current.
2 Up to 20 MHz
3 From 5 Hz – 1 MHz
4 Time for output voltage to recover within 0.5% of its rated output for a load change from 10 to 90% of its rated output current.
Voltage set point from 10% to 100% of rated output
5 Add this to the output reponse time to obtain the total programming time
6 Time to provide data back to the controller using LAN interface (does not include A/D conversion time)
7 From 5 Hz – 1 MHz, at 10% to 100% of output voltage at full load (for 6 V units from 33% to 100% of output voltage)
7

Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 40°C.
N5767A N5768A N5769A N5770A N5771A N5772A
DC output ratings1 Voltage 60 V 80 V 100 V 150 V 300 V 600 V
Current 25 A 19 A 15 A 10 A 5 A 2.6 A
Power 1500 W 1520 W 1500 W 1500 W 1500 W 1560 W
Output ripple and noise CV p-p260 mV 80 mV 80 mV 100 mV 150 mV 300 mV
CV rms38 mV 8 mV 8 mV 12 mV 20 mV 60 mV
Load effect
(change from 10% to 90%)
Voltage 8 mV 10 mV 12 mV 17 mV 32 mV 62 mV
Current 10 mA 8.8 mA 8 mA 7 mA 6 mA 5.5 mA
Source effect
(change from 85-132 VAC input
or 170-265 VAC input)
Voltage 8 mV 10 mV 12 mV 17 mV 32 mV 62 mV
Current 4.5 mA 3.9 mA 3.5 mA 3 mA 2.5 mA 2.26 mA
Programming accuracy1Voltage 0.05%+ 30 mV 40 mV 50 mV 75 mV 150 mV 300 mV
Current 0.1%+ 25 mA 19 mA 15 mA 10 mA 5 mA 2.6 mA
Measurement accuracy Voltage 0.1%+ 60 mV 80 mV 100 mV 150 mV 300 mV 600 mV
Current 0.1%+ 75 mA 57 mA 45 mA 30 mA 15 mA 7.8 mA
Load transient recovery time4Time ≤1 ms ≤1 ms ≤1 ms ≤2 ms ≤2 ms ≤2 ms
Supplemental Characteristics Supplemental characteristics are not warranted but are descriptions of typical
performance determined either by design or type testing
Output response time
(settle to within ±1.0% of the
rated output, with a resistive
load)
Up, full load 0.08 s 0.15 s 0.15 s 0.15 s 0.15 s 0.25 s
Down, full load 0.08 s 0.15 s 0.15 s 0.15 s 0.15 s 0.30 s
Down, no load 1.1 s 1.2 s 1.5 s 2.0 s 3.0 s 4.0 s
Command response time555 ms
Data readback transfer time63 ms
Remote sense compensation Volts/load lead 3 V 4 V 5 V 5 V 5 V 5 V
Over-voltage protection Range 5–66 V 5–88 V 5–110 V 5–165 V 5–330 V 5–660 V
Accuracy 0.60 V 0.80 V 1 V 1.5 V 3 V 6 V
Output ripple and noise7CC rms 75 mA 57 mA 45 mA 35 mA 25 mA 12 m
Programming resolution
measurement resolution
Voltage 7.2 mV 9.6 mV 12 mV 18 mV 36 mV 72 mV
Current 3 mA 2.28 mA 1.8 mA 1.2 mA 0.6 mA 0.312 mA
Front panel display accuracy
(4 digits; ±1 count)
Voltage 0.3 V 0.4 V 0.5 V 0.75 V 1.5 V 3 V
Current 0.125 A 0.095 A 0.075 A 0.050 A 0.025 A 0.013 A
Notes:
1 Minimum voltage is guaranteed to a maximum of 0.2% of the rated output voltage.
Minimum current is guaranteed to a maximum of 0.4% of the rated output current.
2 Up to 20 MHz
3 From 5 Hz – 1 MHz
4 Time for output voltage to recover within 0.5% of its rated output for a load change from 10 to 90% of its rated output current.
Voltage set point from 10% to 100% of rated output
5 Add this to the output reponse time to obtain the total programming time
6 Time to provide data back to the controller using LAN interface (does not include A/D conversion time)
7 From 5 Hz – 1 MHz, at 10% to 100% of output voltage at full load (for 6 V units from 33% to 100% of output voltage)
8
Series and parallel capability
Parallel operation
Up to 4 units can be connected in
master/slave mode
Series operation
Up to 2 units can be connected in
series
Output terminal isolation
6 V to 60 V units
No output terminal may be more than
±60 VDC from any other terminal or
chassis ground
80 V to 600 V units
No output terminal may be more than
±600 VDC from any other terminal or
chassis ground
Store-recall states
Volatile memory locations: 16
Analog programming
(of output voltage and current)
Input signal
Selectable;
0 to 5 V / 0 to 10 V full scale
Input impedance
Selectable;
0 to 5 kΩ / 0 to 10 kΩ full scale
Interface capabilities
GPIB
SCPI – 1993, IEEE 488.2 compliant
interface
USB 2.0
Requires Keysight I/O library version
L.01.01
10/100 LAN
Requires Keysight I/O library version
L.01.01
Web server
Built-in Web server requires Internet
Explorer 5+ or Netscape 6.2+
Environmental conditions
Environment
Indoor use, installation category II
(AC input), pollution degree 2
Operating temperature
0°C to 40°C @ 100% load
Storage temperature
–20°C to 70°C
Operating humidity
30% to 90% relative humidity
(no condensation)
Storage humidity
10% to 95% relative humidity
(no condensation)
Altitude
Up to 3000 meters.
Derate the output current by
2%/100 m above 2000 m.
Derate the maximum ambient
temperature by 1 °C/100 m above
2000 m.
Regulatory compliance
EMC
European EMC directive 89/336/
EEC for Class A products
Australian C- Tick mark
This ISM device complies with
Canadian ICES-001.
Cet appareil ISM est conforme à la
norme NMB-001 du Canada.
Safety
European Low Voltage Directive
73/23/EEC
US and Canadian safety standards
Any LEDs used in this product are
Class 1 as per IEC 825-1
Acoustic noise declaration
Emission directive:
Sound pressure Lp <70 dB(A),
At operator position,
*Normal operation,
*According to EN 27779 (Type
Test).
Schalldruckpegel Lp <70 dB(A)
*Am Arbeitsplatz, *Normaler
Betrieb, *Nach EN 27779
(Typprüfung).
AC input
Nominal input
100 – 240 VAC; 50/60 Hz
Input current 750 W
10.5 A @ 100 VAC nominal;
5 A @ 200 VAC nominal
Input current 1500 W
21 A @ 100 VAC nominal;
11 A @ 200 VAC nominal
Input range
85 – 265 VAC; 47 – 63 Hz.
Power factor
0.99 at nominal input and rated
output power
Efficiency
76% – 87% for 750 W units;
77% – 88% for 1500 W units
Inrush current
<25 A for 750 W units;
<50 A for 1500 W units
Dimensions
(excluding connectors, and handles)
Height 43.6 mm (1.72 in)
Width 422.8 mm (16.65 in)
Depth 432.8 mm (17.04 in)
Weight
750 W 7 Kg (15.4 lbs.)
1500 W 8.5 Kg (18.7 lbs.)
WARNING Shock Hazard
For models up to 60 VDC rated output, no point on the output shall be more than ± 60 VDC above or below chassis ground.
For models greater than 60 VDC rated output, no point on the Positive output shall be more than ± 600 VDC above or below
chassis ground.
For models greater than 60 VDC rated output, no point on the Negative output shall be more than ± 400 VDC above or
below chassis ground.
Supplemental Characteristics for All Model Numbers
9
+S+LSNC-LC-S
SW1
GPIB
ANALOG PROGRAMMING NOT ACTIVE AC INPUT
J2
J1
TX
LINK
ON
OFF
10/100 Ethernet
422.8 mm
+V –V
1 2 3 4 5 6 7 8 9
DC AMPSDC VOLTS
PROT FINE LIMIT
POWER
UVL
OVP
OCP REM OUT ON
VOLTAGE CURRENT
N5749A
100 V / 7.5 A / 750 W
Sytem DC Power Supply
482.8 mm
43.6 mm
507.0 mm
433.0 mm
57.8 mm 92.0 mm 92.0 mm
21.0 mm
A A A
Outline Diagram
AC input
Strain-relief detail
1500 W models
DC output
Bus-bar detail
6 V to 60 V
models
39.5 mm
30.0 mm
22.0 mm
8.5 mm
3.0 mm 35.0 mm
10
Front and Rear Panel Detail
Rear Panel*
(6 V to 60 V, 1500 W Models)
(80 V to 600 V, 1500 W Models)
(6 V to 60 V, 750 W Models)
(80 V to 600 V, 750 W Models)
Front Panel
(All Models)
= air flow (in front, out rear)
11
Ordering Information
Available models
750 W Models
N5741A System DC Power Supply 6 V, 100 A, 600 W
N5742A System DC Power Supply 8 V, 90 A, 720 W
N5743A System DC Power Supply 12.5 V, 60 A, 750 W
N5744A System DC Power Supply 20 V, 38 A, 760 W
N5745A System DC Power Supply 30 V, 25 A, 750 W
N5746A System DC Power Supply 40 V, 19 A, 760 W
N5747A System DC Power Supply 60 V, 12.5 A, 750 W
N5748A System DC Power Supply 80 V, 9.5 A, 760 W
N5749A System DC Power Supply 100 V, 7.5 A, 750 W
N5750A System DC Power Supply 150 V, 5 A, 750 W
N5751A System DC Power Supply 300 V, 2.5 A, 750 W
N5752A System DC Power Supply 600 V, 1.3 A, 780 W
1500 W Models
N5761A System DC Power Supply 6 V, 180 A, 1080 W
N5762A System DC Power Supply 8 V, 165 A, 1320 W
N5763A System DC Power Supply 12.5 V, 120 A, 1500 W
N5764A System DC Power Supply 20 V, 76 A, 1520 W
N5765A System DC Power Supply 30 V, 50 A, 1500 W
N5766A System DC Power Supply 40 V, 38 A, 1520 W
N5767A System DC Power Supply 60 V, 25 A, 1500 W
N5768A System DC Power Supply 80 V, 19 A, 1520 W
N5769A System DC Power Supply 100 V, 15 A, 1500 W
N5770A System DC Power Supply 150 V, 10 A, 1500 W
N5771A System DC Power Supply 300 V, 5 A, 1500 W
N5772A System DC Power Supply 600 V, 2.6 A, 1560 W
Options
750 W Models
Opt 900 Power Cord, United Kingdom
Opt 902 Power Cord, Europe
Opt 903 Power Cord, USA, Canada
Opt 918 Power Cord, Japan
Opt 922 Power Cord, China
1500 W Models
Opt 861 Unterminated Power Cord,
USA, Canada, Japan, China,
Other
Opt 862 Harmonized Unterminated
Power Cord, Europe
Accessories
N5740A Rack Mount Slide Kit
(required for rack mounting;
standard system 11 rack-
mounting hardware will not
work)
Related Literature
These application notes will help you
compare Keysight system DC sources
with power supplies from other
manufacturers:
Side-by-Side Comparison: Keysight
N5700 Series System DC Source
and Sorensen DLM DC Power
Supply, AN 1502-1, 5989-1628EN
http://literature.cdn.keysight.com/
5989-1628EN.pdf
How to Convert from a Sorensen
DLM to an Keysight N5700,
AN 1503-1, 5989-1629EN
http://literature.cdn.keysight.com/
5989-1629EN.pdf
Side-by-Side Comparison:
Keysight N5700 Series System DC
Source and Xantrex XFR System
Power Supplies, AN 1502-2,
5989-1630EN
http://literature.cdn.keysight.com/
5989-1630EN.pdf
How to Convert from a Xantrex
XFR to an Keysight N5700,
AN 1503-2, 5989-1631EN
http://literature.cdn.keysight.com/
5989-1631EN.pdf
Trends in Medium Power (~1 kW)
DC Power Supplies, 5989-1331EN
http://literature.cdn.keysight.com/
5989-1331EN.pdf
Keysight’s IO Libraries Suite ships
with the N5700 to help you quickly
establish an error-free connection
between your PC and instruments -
regardless of the vendor. It provides
robust instrument control and works
with the software development
environment you choose.
For additional description of
Keysight’s IO Libraries Suite
features and installation require-
ments, please go to
www.keysight.com/find/iosuite-
datasheet
myKeysight
www.keysight.com/find/mykeysight
A personalized view into the information most relevant to you.
www.axiestandard.org
AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is an
open standard that extends the AdvancedTCA for general purpose and
semiconductor test. Keysight is a founding member of the AXIe consortium.
www.lxistandard.org
LAN eXtensions for Instruments puts the power of Ethernet and the
Web inside your test systems. Keysight is a founding member of the LXI
consortium.
www.pxisa.org
PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a
rugged, PC-based high-performance measurement and automation system.
Three-Year Warranty
www.keysight.com/find/ThreeYearWarranty
Keysight’s commitment to superior product quality and lower total cost
of ownership. The only test and measurement company with three-year
warranty standard on all instruments, worldwide.
Keysight Assurance Plans
www.keysight.com/find/AssurancePlans
Up to five years of protection and no budgetary surprises to ensure your
instruments are operating to specification so you can rely on accurate
measurements.
www.keysight.com/quality
Keysight Electronic Measurement Group
DEKRA Certified ISO 9001:2008
Quality Management System
Keysight Channel Partners
www.keysight.com/find/channelpartners
Get the best of both worlds: Keysight’s measurement expertise and product
breadth, combined with channel partner convenience.
www.keysight.com/find/dcpowersupplies
For more information on Keysight
Technologies’ products, applications or
services, please contact your local Keysight
office. The complete list is available at:
www.keysight.com/find/contactus
Americas
Canada (877) 894 4414
Brazil 55 11 3351 7010
Mexico 001 800 254 2440
United States (800) 829 4444

Australia 1 800 629 485
China 800 810 0189
Hong Kong 800 938 693
India 1 800 112 929
Japan 0120 (421) 345
Korea 080 769 0800
Malaysia 1 800 888 848
Singapore 1 800 375 8100
Taiwan 0800 047 866
Other AP Countries (65) 6375 8100
Europe & Middle East
Austria 0800 001122
Belgium 0800 58580
Finland 0800 523252
France 0805 980333
Germany 0800 6270999
Ireland 1800 832700
Israel 1 809 343051
Italy 800 599100
Luxembourg +32 800 58580
Netherlands 0800 0233200
Russia 8800 5009286
Spain 0800 000154
Sweden 0200 882255
Switzerland 0800 805353
Opt. 1 (DE)
Opt. 2 (FR)
Opt. 3 (IT)
United Kingdom 0800 0260637
For other unlisted countries:
www.keysight.com/find/contactus
(BP-06-16-14)
12 | Keysight | N5700 Series System DC Power Supplies - Data Sheet
This information is subject to change without notice.
© Keysight Technologies, 2013 - 2014
Published in USA, August 3, 2014
5989-1330EN