Keysight N5700 Series System DC Power Supplies Models: N5741A-49A, N5750A-52A, N5761A-69A, N5770A-72A Data Sheet Family of Affordable Basic System DC Power Supplies - 24 models: 750 W and 1500 W output power - Up to 600 V and up to 180 A - Small high density 1 U package - Built-in voltage and current measurement - Full protection from over-voltage and over-current - 85-265 Vac universal AC input - Command compatibility for Sorensen DLM and Xantrex XFR DC supplies - LAN, USB, and GPIB interfaces standard - Fully compliant to LXI Class C specification The Keysight Technologies, Inc. N5700 Series system DC power supplies give you just the right performance -- at just the right price -- in a compact (1 U) package. This family of affordable 750 W and 1500 W single-output programmable DC power supplies consists of 24 models for simple DC power applications. They provide stable output power, built-in voltage and current measurement, and output voltage and current from 6 V to 600 V and 1.3 A to 180 A. These economical supplies offer many system-ready features like multiple standard I/O interfaces to simplify and accelerate test-system development for R&D, design validation, and manufacturing engineers in the aerospace/defense, automotive, component and communications industries. Small, high-density package saves you rack space The N5700 provides up to 1500 W in a small space-saving 1 U-high, 19-inchwide package. Its air vents are in the front, side and rear (not on the top or bottom), so you can stack other instruments directly above or below it to save valuable rack space. Easy front-panel operation You can quickly and easily operate the power supply with its rotary knobs and buttons. Using the frontpanel controls, you can make coarse or fine adjustments of output voltage and current, protection settings, and set power-on states (last setting memory or factory default setting). The output voltage and current are displayed simultaneously, and LED indicators show power supply status and operating modes. You can lock the front panel controls to protect against accidental power-supply parameter changes. Extensive device protection To safeguard your device from damage, the N5700 Series power supplies provide over-temperature, over-current and over-voltage protection (OVP) to shut down the power supply output when a fault condition occurs. They also offer an undervoltage limit (UVL) that prevents adjustment of the output voltage below a certain limit. The combination of UVL and OVP capabilities lets you create a protection window for sensitive load circuitry. Simplify system connections The N5700 Series power supplies come standard with GPIB, Ethernet/ LAN, and USB 2.0 interfaces giving you the flexibility to use your I/O interface of choice today and in the future. The N5700 is fully compliant with the LXI Class C specification. Figure 1. Front-panel control knobs and buttons make it easy to use N5700 power supplies. Figure 2. Built-in Ethernet, USB 2.0, and GPIB interfaces enable easy system connections. 2 Remote access and control The built-in Web server provides remote access and control of the instrument via a standard browser such as Microsoft Internet Explorer. Using the Web browser, you can set up, monitor and operate the N5700 remotely. Easy system integration and coniguration To simplify system development, the N5700 comes standard with IVI-COM drivers. The N5700 supports the easyto-use SCPI (Standard Commands for Programmable Instruments). Command compatibility The N5700 includes a compatibility command set for the Xantrex XFR series power supplies, the Sorensen DLM series power supplies, and the Keysight 603x series power supplies. This simplifies system integration when converting to the N5700. For a comparison of these products, see application notes: - Side-by-side comparison: Keysight N5700 Series System DC Source and Sorensen DLM DC Power Supply, AN 1502-1, 5989-1628EN - Side-by-side comparison: Keysight N5700 Series System DC Source and Xantrex XFR AN 1502-2, 5989-1630EN Figure 3. N5700 series web graphical user interface for remote access and control of the power supply. Flexible coniguration: connect multiple units in parallel and series Should you need greater output power, the N5700 series power supplies give you the flexibility to connect in parallel up to four similarly rated units for greater output current and connect two similarly rated units in series for greater output voltage (see output terminal isolation information). Analog programming and monitoring The output voltage and current can be programmed from zero to full scale by either an analog voltage 0 to 5 V or 0 to 10 V or by resistances of 0 to 5 k or 0 to 10 k. 3 Universal AC input All N5700 models have universal AC input so they can be automatically operated from any AC mains input voltage worldwide. They can be operated from line voltages of 85 - 265 Vac, 47 to 63 Hz, with no switch to set or fuses to change when you switch from one voltage standard to another. They also provide power factor correction. Rack mounting The rack mount ears and handles are provided standard with every unit. In addition the N5740A rack mount slide kit makes it easy to integrate an N5700 into a test rack by providing all the necessary hardware to rack mount an N5700 series power supply in only 1 U of rack space. Performance speciications Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 40 C. N5741A N5742A N5743A N5744A N5745A N5746A 1 DC output ratings Voltage 6V 8V 12.5 V 20 V Current Power 100 A 90 A 60 A 38 A 25 A 19 A 600 W 720 W 750 W 760 W 750 W 760 W 60 mV 60 mV 60 mV 60 mV 60 mV 60 mV CV rms 8 mV 8 mV 8 mV 8 mV 8 mV 8 mV Voltage 2.6 mV 2.8 mV 3.25 mV 4 mV 5 mV 6 mV Current 25 mA 23 mA 17 mA 12.6 mA 10 mA 8.8 mA Source effect Voltage (change from 85-132 VAC input Current or 170-265 VAC input) 2.6 mV 2.8 mV 3.25 mV 4 mV 5 mV 6 mV 12 mA 11 mA 8 mA 5.8 mA 4.5 mA 3.9 mA 4 mV 6.25 mV 10 mV 15 mV 20 mV CV p-p2 Output ripple and noise 3 Load effect (change from 10% to 90%) 30 V 40 V Programming accuracy1 Voltage Current 0.1%+ 100 mA 90 mA 60 mA 38 mA 25 mA 19 mA Measurement accuracy Voltage 0.1%+ 6 mV 8 mV 12.5 mV 20 mV 30 mV 40 mV Current 0.1%+ 300 mA 270 mA 180 mA 114 mA 75 mA 57 mA 1.5 ms 1.5 ms 1.5 ms 1 ms 1 ms 1 ms 4 Load transient recovery time Time Supplemental Characteristics Output response time (settle to within 1.0% of the rated output, with a resistive load) 0.05%+ 3 mV Supplemental characteristics are not warranted but are descriptions of typical performance determined either by design or type testing Up, full load 0.08 s 0.08 s 0.08 s 0.08 s 0.08 s 0.08 s Down, full load 0.05 s 0.05 s 0.05 s 0.05 s 0.08 s 0.08 s Down, no load 0.5 s 0.6 s 0.7 s 0.8 s 0.9 s 1.0 s Command response time5 55 ms 6 Data readback transfer time 3 ms Remote sense compensation Volts/load lead 1V 1V 1V 1V 1.5 V 2V Over-voltage protection Range 0.5-7.5 V 0.5-10 V 1-15 V 1-24 V 2-36 V 2-44 V Accuracy 0.06 V 0.08 V 0.125 V 0.20 V 0.30 V 0.40 V Output ripple and noise7 CC rms 200 mA 180 mA 120 mA 76 mA 63 mA 48 mA Programming resolution measurement resolution Voltage 0.72 mV 0.96 mV 1.5 mV 2.4 mV 3.6 mV 4.8 mV Current 12 mA 10.8 mA 7.2 mA 4.56 mA 3 mA 2.3 mA Front panel display accuracy (4 digits; 1 count) Voltage 0.03 V 0.04 V 0.06 V 0.10 V 0.15 V 0.20 V Current 0.50 A 0.45 A 0.30 A 0.19 A 0.13 A 0.10 A Notes: 1 Minimum voltage is guaranteed to a maximum of 0.2% of the rated output voltage. Minimum current is guaranteed to a maximum of 0.4% of the rated output current. 2 Up to 20 MHz 3 From 5 Hz - 1 MHz 4 Time for output voltage to recover within 0.5% of its rated output for a load change from 10 to 90% of its rated output current. Voltage set point from 10% to 100% of rated output 5 Add this to the output reponse time to obtain the total programming time 6 Time to provide data back to the controller using LAN interface (does not include A/D conversion time) 7 From 5 Hz - 1 MHz, at 10% to 100% of output voltage at full load (for 6 V units from 33% to 100% of output voltage) 4 Performance speciications Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 40C. N5747A N5748A N5749A N5750A N5751A N5752A 1 DC output ratings Voltage 60 V 80 V 100 V 150 V Current 12.5 A 9.5 A 7.5 A 5A 2.5 A 1.3 A Power 750 W 760 W 750 W 750 W 750 W 780 W 60 mV 80 mV 80 mV 100 mV 150 mV 300 mV CV p-p2 Output ripple and noise Load effect (change from 10% to 90%) Measurement accuracy 4 Load transient recovery time CV rms 8 mV 8 mV 8 mV 12 mV 20 mV 60 mV Voltage 8 mV 10 mV 12 mV 17 mV 32 mV 62 mV Current 7.5 mA 6.9 mA 6.5 mA 6 mA 5.5 mA 5.26 mA 8 mV 10 mV 12 mV 17 mV 32 mV 62 mV 3.25 mA 2.95 mA 2.75 mA 2.5 mA 2.25 mA 2.13 mA Voltage 0.05%+ 30 mV 40 mV 50 mV 75 mV 150 mV 300 mV Current 0.1%+ 12.5 mA 9.5 mA 7.5 mA 5 mA 2.5 mA 1.3 mA Voltage 0.1%+ 60 mV 80 mV 100 mV 150 mV 300 mV 600 mV Current 0.1%+ 37.5 mA 28.5 mA 22.5 mA 15 mA 7.5 mA 3.9 mA 1 ms 1 ms 1 ms 2 ms 2 ms 2 ms Time Supplemental Characteristics Output response time (settle to within 1.0% of the rated output, with a resistive load) 600 V 3 Source effect Voltage (change from 85-132 VAC input Current or 170-265 VAC input) Programming accuracy1 300 V Supplemental characteristics are not warranted but are descriptions of typical performance determined either by design or type testing Up, full load 0.08 s 0.15 s 0.15 s 0.15 s 0.15 s 0.25 s Down, full load 0.08 s 0.15 s 0.15 s 0.15 s 0.15 s 0.30 s Down, no load 1.1 s 1.2 s 1.5 s 2.0 s 3.0 s 4.0 s Command response time5 55 ms 6 Data readback transfer time 3 ms Remote sense compensation Volts/load lead 3V 4V 5V 5V 5V 5V Over-voltage protection Range 5-66 V 5-88 V 5-110 V 5-165 V 5-330 V 5-660 V Accuracy 0.60 V 0.80 V 1V 1.5 V 3V 6V Output ripple and noise7 CC rms 38 mA 29 mA 23 mA 18 mA 13 mA 8m Programming resolution measurement resolution Voltage 7.2 mV 9.6 mV 12 mV 18 mV 36 mV 72 mV Current 1.5 mA 1.14 mA 0.9 mA 0.6 mA 0.3 mA 0.156 mA Front panel display accuracy (4 digits; 1 count) Voltage 0.3 V 0.4 V 0.5 V 0.75 V 1.5 V 3V Current 0.0625 A 0.0475 A 0.0375 A 0.0250 A 0.0125A 0.0065 A Notes: 1 Minimum voltage is guaranteed to a maximum of 0.2% of the rated output voltage. Minimum current is guaranteed to a maximum of 0.4% of the rated output current. 2 Up to 20 MHz 3 From 5 Hz - 1 MHz 4 Time for output voltage to recover within 0.5% of its rated output for a load change from 10 to 90% of its rated output current. Voltage set point from 10% to 100% of rated output 5 Add this to the output reponse time to obtain the total programming time 6 Time to provide data back to the controller using LAN interface (does not include A/D conversion time) 7 From 5 Hz - 1 MHz, at 10% to 100% of output voltage at full load (for 6 V units from 33% to 100% of output voltage) 5 Performance speciications Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 40C. N5761A N5762A N5763A N5764A N5765A N5766A 1 DC output ratings Voltage 6V Current 180 A 165 A 120 A 76 A 50 A 38 A Power 1080 W 1320 W 1500 W 1520 W 1500 W 1520 W 60 mV 60 mV 60 mV 60 mV 60 mV 60 mV CV rms 8 mV 8 mV 8 mV 8 mV 8 mV 8 mV Voltage 2.6 mV 2.8 mV 3.25 mV 4 mV 5 mV 6 mV Current 41 mA 38 mA 29 mA 20.2 mA 15 mA 12.6 mA Source effect Voltage (change from 85-132 VAC input Current or 170-265 VAC input) 2.6 mV 2.8 mV 3.25 mV 4 mV 5 mV 6 mV 20 mA 18.5 mA 14 mA 9.6 mA 7 mA 5.8 mA CV p-p2 Output ripple and noise 3 Load effect (change from 10% to 90%) Programming accuracy1 Measurement accuracy 4 Load transient recovery time 12.5 V 20 V 30 V 40 V Voltage 0.05%+ 3 mV 4 mV 6.25 mV 10 mV 15 mV 20 mV Current 0.1%+ 180 mA 165 mA 120 mA 76 mA 50 mA 38 mA Voltage 0.1%+ 6 mV 8 mV 12.5 mV 20 mV 30 mV 40 mV Current 0.1%+ 540 mA 495 mA 360 mA 228 mA 150 mA 114 mA 1.5 ms 1.5 ms 1.5 ms 1 ms 1 ms 1 ms Time Supplemental characteristics Output response time (settle to within 1.0% of the rated output, with a resistive load) 8V Supplemental characteristics are not warranted but are descriptions of typical performance determined either by design or type testing. Up, full load 0.08 s 0.08 s 0.08 s 0.08 s 0.08 s 0.08 s Down, full load 0.05 s 0.05 s 0.05 s 0.05 s 0.08 s 0.08 s Down, no load 0.5 s 0.6 s 0.7 s 0.8 s 0.9 s 1.0 s Command response time5 55 ms 6 Data readback transfer time 3 ms Remote sense compensation Volts/load lead 1V 1V 1V 1V 1.5 V 2V Over-voltage protection Range 0.5-7.5 V 0.5-10 V 1-15 V 1-24 V 2-36 V 2-44 V Accuracy 0.06 V 0.08 V 0.125 V 0.20 V 0.30 V 0.40 V Output ripple and noise7 CC rms 360 mA 330 mA 240 mA 152 mA 125 mA 95 mA Programming resolution measurement resolution Voltage 0.72 mV 0.96 mV 1.5 mV 2.4 mV 3.6 mV 4.8 mV Current 21.6 mA 19.8 mA 14.4 mA 9.12 mA 6 mA 4.6 mA Front panel display accuracy (4 digits; 1 count) Voltage 0.03 V 0.04 V 0.0625 V 0.1 V 0.15 V 0.2 V Current 0.90 A 0.825 A 0.60 A 0.38 A 0.25 A 0.19 A Notes: 1 Minimum voltage is guaranteed to a maximum of 0.2% of the rated output voltage. Minimum current is guaranteed to a maximum of 0.4% of the rated output current. 2 Up to 20 MHz 3 From 5 Hz - 1 MHz 4 Time for output voltage to recover within 0.5% of its rated output for a load change from 10 to 90% of its rated output current. Voltage set point from 10% to 100% of rated output 5 Add this to the output reponse time to obtain the total programming time 6 Time to provide data back to the controller using LAN interface (does not include A/D conversion time) 7 From 5 Hz - 1 MHz, at 10% to 100% of output voltage at full load (for 6 V units from 33% to 100% of output voltage) 6 Performance speciications Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 40C. N5767A N5768A N5769A N5770A N5771A N5772A 1 DC output ratings Voltage 60 V Current 25 A 19 A 15 A 10 A 5A 2.6 A Power 1500 W 1520 W 1500 W 1500 W 1500 W 1560 W 60 mV 80 mV 80 mV 100 mV 150 mV 300 mV CV p-p2 Output ripple and noise Load effect (change from 10% to 90%) Measurement accuracy 4 Load transient recovery time 150 V 300 V 600 V CV rms 8 mV 8 mV 8 mV 12 mV 20 mV 60 mV Voltage 8 mV 10 mV 12 mV 17 mV 32 mV 62 mV Current 10 mA 8.8 mA 8 mA 7 mA 6 mA 5.5 mA 8 mV 10 mV 12 mV 17 mV 32 mV 62 mV 4.5 mA 3.9 mA 3.5 mA 3 mA 2.5 mA 2.26 mA Voltage 0.05%+ 30 mV 40 mV 50 mV 75 mV 150 mV 300 mV Current 0.1%+ 25 mA 19 mA 15 mA 10 mA 5 mA 2.6 mA Voltage 0.1%+ 60 mV 80 mV 100 mV 150 mV 300 mV 600 mV Current 0.1%+ 75 mA 57 mA 45 mA 30 mA 15 mA 7.8 mA 1 ms 1 ms 1 ms 2 ms 2 ms 2 ms Time Supplemental Characteristics Output response time (settle to within 1.0% of the rated output, with a resistive load) 100 V 3 Source effect Voltage (change from 85-132 VAC input Current or 170-265 VAC input) Programming accuracy1 80 V Supplemental characteristics are not warranted but are descriptions of typical performance determined either by design or type testing Up, full load 0.08 s 0.15 s 0.15 s 0.15 s 0.15 s 0.25 s Down, full load 0.08 s 0.15 s 0.15 s 0.15 s 0.15 s 0.30 s Down, no load 1.1 s 1.2 s 1.5 s 2.0 s 3.0 s 4.0 s Command response time5 55 ms 6 Data readback transfer time 3 ms Remote sense compensation Volts/load lead 3V 4V 5V 5V 5V 5V Over-voltage protection Range 5-66 V 5-88 V 5-110 V 5-165 V 5-330 V 5-660 V Accuracy 0.60 V 0.80 V 1V 1.5 V 3V 6V 7 Output ripple and noise CC rms 75 mA 57 mA 45 mA 35 mA 25 mA 12 m Programming resolution measurement resolution Voltage 7.2 mV 9.6 mV 12 mV 18 mV 36 mV 72 mV Current 3 mA 2.28 mA 1.8 mA 1.2 mA 0.6 mA 0.312 mA Front panel display accuracy (4 digits; 1 count) Voltage 0.3 V 0.4 V 0.5 V 0.75 V 1.5 V 3V Current 0.125 A 0.095 A 0.075 A 0.050 A 0.025 A 0.013 A Notes: 1 Minimum voltage is guaranteed to a maximum of 0.2% of the rated output voltage. Minimum current is guaranteed to a maximum of 0.4% of the rated output current. 2 Up to 20 MHz 3 From 5 Hz - 1 MHz 4 Time for output voltage to recover within 0.5% of its rated output for a load change from 10 to 90% of its rated output current. Voltage set point from 10% to 100% of rated output 5 Add this to the output reponse time to obtain the total programming time 6 Time to provide data back to the controller using LAN interface (does not include A/D conversion time) 7 From 5 Hz - 1 MHz, at 10% to 100% of output voltage at full load (for 6 V units from 33% to 100% of output voltage) 7 WARNING Shock Hazard - For models up to 60 VDC rated output, no point on the output shall be more than 60 VDC above or below chassis ground. - For models greater than 60 VDC rated output, no point on the Positive output shall be more than 600 VDC above or below chassis ground. - For models greater than 60 VDC rated output, no point on the Negative output shall be more than 400 VDC above or below chassis ground. Supplemental Characteristics for All Model Numbers Series and parallel capability Parallel operation Up to 4 units can be connected in master/slave mode Series operation Up to 2 units can be connected in series Output terminal isolation 6 V to 60 V units No output terminal may be more than 60 VDC from any other terminal or chassis ground 80 V to 600 V units No output terminal may be more than 600 VDC from any other terminal or chassis ground Store-recall states Volatile memory locations: 16 Analog programming (of output voltage and current) Input signal Selectable; 0 to 5 V / 0 to 10 V full scale Input impedance Selectable; 0 to 5 k / 0 to 10 k full scale Interface capabilities GPIB SCPI - 1993, IEEE 488.2 compliant interface USB 2.0 Requires Keysight I/O library version L.01.01 10/100 LAN Requires Keysight I/O library version L.01.01 Web server Built-in Web server requires Internet Explorer 5+ or Netscape 6.2+ Environmental conditions Environment Indoor use, installation category II (AC input), pollution degree 2 Operating temperature 0C to 40C @ 100% load Storage temperature -20C to 70C Operating humidity 30% to 90% relative humidity (no condensation) Storage humidity 10% to 95% relative humidity (no condensation) Altitude - Up to 3000 meters. Derate the output current by 2%/100 m above 2000 m. - Derate the maximum ambient temperature by 1 C/100 m above 2000 m. Regulatory compliance EMC - European EMC directive 89/336/ EEC for Class A products - Australian C- Tick mark - This ISM device complies with Canadian ICES-001. - Cet appareil ISM est conforme a la norme NMB-001 du Canada. Safety - European Low Voltage Directive 73/23/EEC - US and Canadian safety standards - Any LEDs used in this product are Class 1 as per IEC 825-1 8 Acoustic noise declaration Emission directive: - Sound pressure Lp <70 dB(A), At operator position, *Normal operation, *According to EN 27779 (Type Test). - Schalldruckpegel Lp <70 dB(A) *Am Arbeitsplatz, *Normaler Betrieb, *Nach EN 27779 (Typprufung). AC input Nominal input 100 - 240 VAC; 50/60 Hz Input current 750 W 10.5 A @ 100 VAC nominal; 5 A @ 200 VAC nominal Input current 1500 W 21 A @ 100 VAC nominal; 11 A @ 200 VAC nominal Input range 85 - 265 VAC; 47 - 63 Hz. Power factor 0.99 at nominal input and rated output power Efficiency 76% - 87% for 750 W units; 77% - 88% for 1500 W units Inrush current <25 A for 750 W units; <50 A for 1500 W units Dimensions (excluding connectors, and handles) Height 43.6 mm (1.72 in) Width 422.8 mm (16.65 in) Depth 432.8 mm (17.04 in) Weight 750 W 7 Kg (15.4 lbs.) 1500 W 8.5 Kg (18.7 lbs.) Outline Diagram VOLTAGE DC VOLTS DC AMPS CURRENT N5749A 43.6 mm 100 V / 7.5 A / 750 W Sytem DC Power Supply PROT FINE OVP LIMIT UVL OCP REM OUT ON POWER 482.8 mm LINK GPIB J2 SW1 10/100 Ethernet TX +V -V J1 ON OFF +S+LSNC-LC-S 123456789 ANALOG PROGRAMMING AC INPUT NOT ACTIVE 422.8 mm 507.0 mm A A A 21.0 mm 57.8 mm 92.0 mm 92.0 mm 433.0 mm 39.5 mm 3.0 mm AC input Strain-relief detail 1500 W models DC output Bus-bar detail 6 V to 60 V models 22.0 mm 30.0 mm 8.5 mm 9 35.0 mm Front and Rear Panel Detail Front Panel (All Models) = air flow (in front, out rear) Rear Panel* (6 V to 60 V, 1500 W Models) (80 V to 600 V, 1500 W Models) (6 V to 60 V, 750 W Models) (80 V to 600 V, 750 W Models) 10 Ordering Information Available models Options 750 W Models 750 W Models N5741A System DC Power Supply 6 V, 100 A, 600 W N5742A System DC Power Supply 8 V, 90 A, 720 W N5743A System DC Power Supply 12.5 V, 60 A, 750 W N5744A System DC Power Supply 20 V, 38 A, 760 W N5745A System DC Power Supply 30 V, 25 A, 750 W N5746A System DC Power Supply 40 V, 19 A, 760 W N5747A System DC Power Supply 60 V, 12.5 A, 750 W N5748A System DC Power Supply 80 V, 9.5 A, 760 W N5749A System DC Power Supply 100 V, 7.5 A, 750 W N5750A System DC Power Supply 150 V, 5 A, 750 W N5751A System DC Power Supply 300 V, 2.5 A, 750 W N5752A System DC Power Supply 600 V, 1.3 A, 780 W N5761A System DC Power Supply 6 V, 180 A, 1080 W N5762A System DC Power Supply 8 V, 165 A, 1320 W N5763A System DC Power Supply 12.5 V, 120 A, 1500 W N5764A System DC Power Supply 20 V, 76 A, 1520 W N5765A System DC Power Supply 30 V, 50 A, 1500 W N5766A System DC Power Supply 40 V, 38 A, 1520 W N5767A System DC Power Supply 60 V, 25 A, 1500 W N5768A System DC Power Supply 80 V, 19 A, 1520 W N5769A System DC Power Supply 100 V, 15 A, 1500 W N5770A System DC Power Supply 150 V, 10 A, 1500 W N5771A System DC Power Supply 300 V, 5 A, 1500 W N5772A System DC Power Supply 600 V, 2.6 A, 1560 W Opt 900 Opt 902 Opt 903 Opt 918 Opt 922 Power Cord, United Kingdom Power Cord, Europe Power Cord, USA, Canada Power Cord, Japan Power Cord, China 1500 W Models Opt 861 Unterminated Power Cord, USA, Canada, Japan, China, Other Opt 862 Harmonized Unterminated Power Cord, Europe Accessories 1500 W Models Related Literature These application notes will help you compare Keysight system DC sources with power supplies from other manufacturers: - Side-by-Side Comparison: Keysight N5700 Series System DC Source and Sorensen DLM DC Power Supply, AN 1502-1, 5989-1628EN http://literature.cdn.keysight.com/ 5989-1628EN.pdf - How to Convert from a Sorensen DLM to an Keysight N5700, AN 1503-1, 5989-1629EN - Side-by-Side Comparison: Keysight N5700 Series System DC Source and Xantrex XFR System Power Supplies, AN 1502-2, 5989-1630EN http://literature.cdn.keysight.com/ 5989-1630EN.pdf - How to Convert from a Xantrex XFR to an Keysight N5700, AN 1503-2, 5989-1631EN http://literature.cdn.keysight.com/ 5989-1631EN.pdf - Trends in Medium Power (~1 kW) DC Power Supplies, 5989-1331EN http://literature.cdn.keysight.com/ 5989-1331EN.pdf http://literature.cdn.keysight.com/ 5989-1629EN.pdf 11 N5740A Rack Mount Slide Kit (required for rack mounting; standard system 11 rackmounting hardware will not work) Keysight's IO Libraries Suite ships with the N5700 to help you quickly establish an error-free connection between your PC and instruments regardless of the vendor. It provides robust instrument control and works with the software development environment you choose. For additional description of Keysight's IO Libraries Suite features and installation requirements, please go to www.keysight.com/find/iosuitedatasheet 12 | Keysight | N5700 Series System DC Power Supplies - Data Sheet myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.axiestandard.org AdvancedTCA(R) Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Keysight is a founding member of the AXIe consortium. www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Keysight is a founding member of the LXI consortium. www.pxisa.org PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high-performance measurement and automation system. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight's commitment to superior product quality and lower total cost of ownership. The only test and measurement company with three-year warranty standard on all instruments, worldwide. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. www.keysight.com/quality Keysight Electronic Measurement Group DEKRA Certified ISO 9001:2008 Quality Management System Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight's measurement expertise and product breadth, combined with channel partner convenience. www.keysight.com/find/dcpowersupplies For more information on Keysight Technologies' products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada Brazil Mexico United States (877) 894 4414 55 11 3351 7010 001 800 254 2440 (800) 829 4444 Asia Paciic Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries 1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 (65) 6375 8100 Europe & Middle East Austria Belgium Finland France Germany Ireland Israel Italy Luxembourg Netherlands Russia Spain Sweden Switzerland United Kingdom 0800 001122 0800 58580 0800 523252 0805 980333 0800 6270999 1800 832700 1 809 343051 800 599100 +32 800 58580 0800 0233200 8800 5009286 0800 000154 0200 882255 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-06-16-14) This information is subject to change without notice. (c) Keysight Technologies, 2013 - 2014 Published in USA, August 3, 2014 5989-1330EN www.keysight.com