GLQ110 Series Specifications
Input
Input ra nge 85-264 Vac; 120-300 Vdc
Frequency 47-440 Hz
Inrush current <18 A peak @ 115 Vac; <36 A peak @ 230 Vac, cold start @ 25°C
Efficiency 70% typical at full load
EMI filter Meets FCC Class B conducted; CISPR 22 Class B conducted;
EN55022 Class B conducted; VDE 0878 PT3 Class B conducted
Safety ground
leakage current <0.5 mA @ 50/60 Hz, 264 Vac input
Output
Maximum power 80 W for convection; 110 W with 30 CFM forced air
Adjustment range ±5% min. on main; 5-25 V on 4th output on GLQ112 and GLQ113
Cross regulation ±2% on output 1; ±3% on outputs 2, 3 & 4
Hold-up time 20 ms @ 80 W load, 115 Vac nominal line
Overload protection Short circuit protection on all outputs
Case overload protected @ 110-145% above peak rating
Overvoltage protection 5.7 to 6.7 Vdc on main output; Latching type, recycle AC to reset
Minimum Load 2 A for the first output, 0.5 A for the 4th output of GLQ114
Logic Control
Power failure TTL logic signal goes high 50-150 msec after 5 V output. It goes low at least 4 msec before loss of regulation.
Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected.
Operating temperature 0° to 50°C ambient. Derate each output 2.5% per degree from 50° to 70°C (except for -C version).
Storage temperature -40°C to 85°C
Temperature coefficient ±0.04% per °C
Electromagnetic
susceptibility
Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3
Humidity Operating; non-condensing 5% to 95%
Vibration Three orthogonal axes, sweep at 1 oct/min., 5 min. dwell at four major resonances 0.75G peak 5Hz to 500Hz, operational
MTBF demonstrated >550,000 hours at full load and 25°C ambient conditions
Mating Connectors
AC Input Molex 09-50-8051 (USA)
09-91-0500 (UK); PINS: 08-58-0111
DC Outputs Molex 09-50-8121 (USA)
09-91-1200 (UK); PINS: 08-58-0111
Remote Sense/
Power Fail
Molex 22-01-1022 (USA)
22-01-1023 (UK); PINS: 08-50-0114
Connector Kit #70-841-008, includes all of the above
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02” (±0.5mm).
3. Specifications are for convection rating at factory settings unless otherwise stated.
4. Mounting holes M1 and M2 should be grounded for EMI purposes.
5. Mounting hole M1 is safety ground connection.
6. L bracket mounting (6-32) maximum insertion depth is .20”.
7. Warranty: 2 year
8. Weight: 1.25 lbs/0.57 kg
Phone: (800) 377-4384
Email: tech@solahd.com
www.solahd.com
Electrical Specifications