GLQ110 Series Installation & Operating Instructions Installation & Safety To comply with the published safety standards, the following must be observed when using this power supply: Output Ratings Model 1. Maximum ambient temperature for the power supply must not exceed 50C. 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950, EN60950-1, IEC60950-1, and CSA22.2 No. 234-M90; including the requirements for creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 7. When operating with a dc input voltage range, the unit input must be protected by a dc rated fuse in the end-use installation system. 8. The internal fuse should only be replaced with a 4 A, 250 V ac, Type SP0001.1010 manufactured by Schurter AG, Type 216004 manufactured by Littelfuse or Type S501 manufactured by Cooper. 9. This power supply is Directive, 2006/95/EC. 30 CFM Forced Air Cooling Max. Output Current (A) 9.0 4.5 5 -12 0.7 1.0 5 to 25 2.5 3.0 +5 9.0 11.0 +15 4.5 -15 0.7 5 to 25 2.5 3.0 +5 9.0 11.0 +12 4.5 5.0 -12 0.7 1.0 +24 3.5 4.5 GLQ113 GLQ114 Max. Output Power (W) 11.0 80 5.0 1.0 110 Connector PIN Designation Input Connector SK1 PIN GLQ112 Output Connector GLQ113 1 GND 3 Neutral 5 PIN GLQ114 Line GLQ112 GLQ113 GLQ114 1 2 +5 V 3 4 marked following the provisions of the Low Voltage For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. Max. Output Power (W) +5 5. The earth ground wire must be connected only to the point marked with the earth ground symbol (on the unit). 6. Hazardous voltages exist in the primary circuits. Disconnect the power supply before servicing. Max. Output Current (A) +12 GLQ112 3. The power supply's rated input voltage is automatically selected. Please refer to the specification sheet for the input voltage range. Convection Cooling Output Voltage (V) 5 SK2 SK201 SK202 Common 6 7 8 +12 V +15 V +12 V 9 +12 V +15 V +12 V 10 -12 V -15 V -12 V 11 +5 V to +25 V +5 V to +25 V +24 V 12 -5 V to -25 V -5 V to -25 V Common 1 +Sense 2 -Sense 1 P OK 2 GND P/N: A272-168 Rev 2 12/29/09 Ref: 03361001602 GLQ110 Series Installation & Operating Instructions Mechanical Outline Mechanical Dimensions .25 [6.35] SK201 SK202 3.50 [88.9] 5 ~ 25 V O/P ADJ 5 V O/P ADJ 4.00 [101.6] 1 SK2 1 3 5 .25 [6.35] 12 4.28 [108.6] 2.50 [63.5] SK1 6.50 [165.1] 6.40 [162.6] 7.00 [177.8] 7.30 [185.5] Bottom View with Optional L-Bracket Top View 2.20 [56.0] .86 [21.8] 5.90 [150.0] Side View with Optional L-Bracket All dimensions are in inches [mm] Screw size: #6-32 GLQ112, GLQ113, and GLQ114 are commercial designations of model numbers LPQ112, LPQ113, and LPQ114 respectively. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. GLQ110 Series Specifications Electrical Specifications Input Input range 85-264 Vac; 120-300 Vdc Frequency 47-440 Hz Inrush current <18 A peak @ 115 Vac; <36 A peak @ 230 Vac, cold start @ 25C Efficiency 70% typical at full load Meets FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE 0878 PT3 Class B conducted EMI filter Safety ground leakage current <0.5 mA @ 50/60 Hz, 264 Vac input Output Maximum power 80 W for convection; 110 W with 30 CFM forced air Adjustment range 5% min. on main; 5-25 V on 4th output on GLQ112 and GLQ113 Cross regulation 2% on output 1; 3% on outputs 2, 3 & 4 20 ms @ 80 W load, 115 Vac nominal line Short circuit protection on all outputs Case overload protected @ 110-145% above peak rating Hold-up time Overload protection 5.7 to 6.7 Vdc on main output; Latching type, recycle AC to reset Overvoltage protection 2 A for the first output, 0.5 A for the 4th output of GLQ114 Minimum Load Logic Control TTL logic signal goes high 50-150 msec after 5 V output. It goes low at least 4 msec before loss of regulation. Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Power failure Remote sense Environmental Specifications Operating temperature Storage temperature 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C (except for -C version). -40C to 85C Temperature coefficient Electromagnetic susceptibility Humidity 0.04% per C Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Operating; non-condensing 5% to 95% Three orthogonal axes, sweep at 1 oct/min., 5 min. dwell at four major resonances 0.75G peak 5Hz to 500Hz, operational Vibration >550,000 hours at full load and 25C ambient conditions MTBF demonstrated MatingConnectors AC Input Molex 09-50-8051 (USA) 09-91-0500 (UK); PINS: 08-58-0111 DC Outputs Molex 09-50-8121 (USA) 09-91-1200 (UK); PINS: 08-58-0111 Remote Sense/ Molex 22-01-1022 (USA) Power Fail 22-01-1023 (UK); PINS: 08-50-0114 Connector Kit #70-841-008, includes all of the above 1. Specifications subject to change without notice. 2 . All dimensions in inches (mm), tolerance is 0.02"(0.5mm). 3. Specifications are for convection rating at factory settings unless otherwise stated. 4. 5. 6. 7. 8. Mounting holes M1 and M2 should be grounded for EMI purposes. Mounting hole M1 is safety ground connection. L bracket mounting (6-32) maximum insertion depth is .20". Warranty: 2 year Weight: 1.25 lbs/0.57 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com GLQ123 Installation & Operating Instructions Mechanical Outline To comply with the published safety standards, the following must be observed when using this power supply: 1. Maximum ambient temperature for the power supply must not exceed 50C. 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03; including the requirements for creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. 3. The power supply's rated input voltage is automatically selected. Please refer to the specification sheet for the input voltage range. 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. SK4 SK3 SK2 SK1 5 V Adj. 3.3 V Adj. 5 1 2 3 3 SK5 SK6 1 6 1 10 5 5. The earth ground wire must be connected only to the point marked with the earth ground symbol (on the unit). 6. The disconnection from the line must be in the end system. Connector PIN Designation 7. Hazardous voltages exist in the primary circuits. Disconnect the power supply before servicing. 8. The unit must be protected by a fuse in the end system. Components, such as capacitors, may be positioned in front of the internal fuse. Input Connector SK1 9. The internal fuse should only be replaced with a F4AL, 250 V ac, type 19370 manufactured by Wickmann. Output Connector PIN Designation 1 Earth GND 3 Neutral 5 Line PIN Designation 10. This equipment is considered Class I according to protection against electric shock. SK2 +5 V 11. This power supply is 2006/95/EC. SK3 Common marked following the provisions of the Low Voltage Directive, SK4 12. For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. SK5 Output Ratings 30 CFM Forced Air Cooling (unit not convection rated) Output Voltage (V) Max. Output Current (A) +5 +3.3 +12 -12 24.0 25.0 2.0 1.0 Max. Output Power (W) 120 Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions SK6 +3.3 V 1 +12 V 2 Common 3 -12 V 1 +3.3 V SWP (Single Wire Parallel) 2 -Sense 3 +3.3 V +Sense 4 +5 V SWP (Single Wire Parallel) 5 Common 6 +5 V +Sense 7 -Sense 8 +Inhibit 9 -Inhibit 10 Power Fail P/N: A272-189 Rev 0 5/21/09 Ref: NTQ123\OP GLQ123 Installation & Operating Instructions a Typical Ventilation Setup a .75 [19.0] 1.50[38.1] Mechanical Dimensions 6.50 [165.1] Side View Air Flow 4.72 [120.0] System Chassis Ac Input 2.85 [72.5] F A N F A N F A N 10.43 [265.0] 1.13 [28.7] b a 4.71 [119.6] 5.50 [139.7] 7.00 [177.8] Output 1.72 [43.8] a b 4.00 [101.6] 2.50 [63.5] a 1.00 [25.4] 11.81 [300.0] 30 CFM forced air cooling NOTE: Dimensions and fan used are for reference only Bottom View All dimensions are in inches [mm] Screw size: a = #6-32 (U.S.); b = M3 (International) Maximum screw protrusion: 0.6 [1.5 mm] Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. GLQ123 is a commercial designation of model number NTQ123. GLQ123 Specifications Electrical Specifications Input Input range 85-264 Vac; 120-300 Vdc Frequency 47-63 Hz 38 A max, cold start @ 25C Inrush current 65% typical at full load FCC Class B conducted and radiated; CISPR 22 Class B conducted and radiated; EN55022 Class B conducted and radiated; VDE 0878 PT3 Class B conducted and radiated Efficiency EMI filter 0.99 typical Power factor Safety ground leakage current <1 mA @ 50/60 Hz, 264 Vac input Output Maximum power 70 W for convection; 120 W with 30 CFM forced air Adjustment range 5% min. on outputs one and two Overload protection 20 ms @ 120 W load, 120 Vac input Short circuit protection on all outputs Case overload protected @ 110-145% above peak rating Overvoltage protection 3.3 to 5 V output; 20% to 35% above nominal output Hold-up time 2 A for the second output Minimum Load Logic Control TTL logic signal goes high 100-500 msec after 5 V output. It goes low at least 4 msec before loss of regulation. Requires an external TTL Signal to inhibit outputs Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Power failure Remote inhibit Remote sense Environmental Specifications Operating temperature Storage temperature 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C -40C to 85C Temperature coefficient Electromagnetic susceptibility Humidity 0.04% per C Designed to meet EN61000-4, -2, -3, -4, -5, -6, -8, -11, Level 3 Operating; non-condensing 5% to 95% Three orthogonal axes, sweep at 1 oct/min., 5 min. dwell at four major resonances 0.7G peak 5Hz to 500Hz, operational Vibration >1 million hours at full load and 25C ambient conditions MTBF demonstrated Mating Connectors (SK1) AC Input Molex 09-50-8051 (USA) 09-91-0500 (UK); PINS: 08-58-0111 SK2,3,4 Molex series 19141-0058/0063 (SK5) 12 V Molex 09-50-8031 (USA) 09-91-0300 (UK); PINS: 08-58-0111 (SK6) Control Molex 90142-0010; PINS: 90119-2110 or Signals Amp: 87977-3; PINS: 87309-8 Connector Kit #70-841-012, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02" (0.5mm). 3. Remote inhibit requires an external 5 V @ 10 mA to activate. 4. Mounting maximum insertion depth is 0.12". 5. Warranty: 1 year 6. Weight: 1.38 lbs/0.63 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com GLQ142 Installation & Operating Instructions Mechanical Outline To comply with the published safety standards, the following must be observed when using this power supply: 1. Maximum ambient temperature for the power supply must not exceed 50C. Derate each output 2.5% per degree from 50C to 70C ambient temperature. P252 V1 Adj. 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03; including the requirements for creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. Fine Course V4 Adj. 1 2 SK5 6 3. The ac-dc input connector is approved as a component of the power supply, however, it was not specifically evaluated to IEC60320. 4. This power supply is approved and certified for the rated voltage range of 100 V ac to 250 V ac and/or 120 V dc (minimum) to 370 V dc (maximum). SK3 P251 SK2 5 SK1 3 1 1 SK6 5. The earth ground wire must be connected only to the point marked with the earth ground symbol (on the unit). 5 10 1 6 6. The disconnection from the line must be in the end system. 7. When operating with a dc input voltage range, the dc source must be rectified from a mains supply not exceeding 250 V ac. The unit input must also be protected by a dc rated fuse in the end-use installation system. Connector PIN Designation Input Connector PIN Designation 8. The internal fuse (F1) should only be replaced by a 4 A, 250 V ac, type GDA-V/S501 manufactured by Bussman. SK1 1 3 5 Earth GND Neutral Line 9. This equipment is considered Class I according to protection against electric shock. Output Connector PIN Designation 1 2, 4 3 5 6 P251 P252 1 2 1 2 3 4 5 6 7 8 9 10 V2 Common V3 V4 V4 (Return) Common V1 V2 Common V4 SWP (Single Wire Parallel) Dc OK +V4 Sense V1 SWP (Single Wire Parallel) Common +V1 Sense Sense Common +Inhibit -Inhibit Power Fail 10. This power supply is 2006/95/EC. marked following the provisions of the Low Voltage Directive, SK2 11. For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. SK5 Output Ratings Convection Cooling Output Voltage (V) Max. Output Current (A) Max. Output Power (W) V1: +3.3 to +5.7 12.0 V2: +12.0 to +12.7 5.0 80 without cover V3: -12.0 to -15.0 1.0 60 with cover V4: +3.3 to +25.0 1.5 SK3 (optional for units with cover & fan) 30 CFM Forced Air Cooling Max. Output Current (A) 25.0 Max. Output Power (W) SK6 6.0 145 with or without cover 1.5 145 with cover & internal fan 4.5 Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions P/N: A272-177 Rev 0 6/1/09 Ref: LPQ142/OP.C GLQ142 Installation & Operating Instructions Mechanical Dimensions B B 1.54 [39.1] 0.75 [19.1] 1.50 [38.1] A POWER SUPPLY FAN 6.36 [161.5] 6.75 [171.5] MIN 30 CFM A INPUT CONNECTOR 1.54 [39.1] 3.07 [78.0] Side View B A Top View 3.35 [85.1] VENTILATION BOX B 2.36 [60.0] 4.00 [101.6] F A N AIR FLOW MIN 30 CFM 2.50 [63.5] POWER SUPPLY INPUT CONNECTOR 5.00 [127.0] 14.37 [365.0] B A A 5.04 [128.1] .39 [9.9] 0.25 [6.4] AIR FLOW .39 [9.9] A B Side View 1.77 [45.0] 1.15 [29.1] Typical Ventilation Setup 30 CFM forced air cooling NOTE: Dimensions and fan used are for reference only 4.71 [119.6] 5.50 [139.7] 7.00 [177.8] Bottom View All dimensions are in inches [mm] Screw sizes: A = M3 (International); B = #6-32 (U.S.) Recommended maximum screw protrusion: 0.06 [1.5 mm] Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. GLQ142 is a commercial designation of model number LPQ142. GLQ142 Specifications Electrical Specifications Input 85-264 Vac; 120-300 Vdc 47-67 Hz 38 A max, cold start @ 25C 75% typical at full load FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE 0878 PT3 Class B conducted Input range Frequency Inrush current Efficiency EMI filter 0.99 typical Power factor Safety ground leakage current 1.0 mA @ 50/60 Hz, 264 Vac input Output 80 W convection (60 W with cover) 145 W with 30 CFM forced air (100 W with cover) 3.3 - 5.5 V on main; -12 - 15 V on 3rd output; 3.3 - 25 V on 4th output Maximum power Adjustment range 20 ms @ 175 W load at nominal line Short circuit protection on all outputs Case overload protected @ 110-145% above peak rating Tracks outputs 1, 3 & 4; 10 to 35% Hold-up time Overload protection Overvoltage protection 0.5 A for the 4th output Minimum Load Logic Control AC Power failure TTL logic signal goes high 100-500 msec after V1 output. It goes low at least 4 msec before loss of regulation. Requires contact closure to inhibit outputs Remote inhibit Remote sense DC - OK Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. TTL logic signal goes high after main output is in regulation. It goes low when there is a loss of regulation. Environmental Specifications Operating temperature 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C (except for -C version). Storage temperature Temperature coefficient Electromagnetic susceptibility -40C to 85C 0.4% per C Designed to meet IE61000-4, -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity Operating; non-condensing 5% to 95% Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75 G peak 5 Hz to 500 Hz, operational >550,000 hours at full load and 25C ambient conditions MTBF demonstrated Mating Connectors (SK1) AC Input Molex 09-50-8051 (USA) Molex 09-91-0500 (UK); PINS: 08-58-0111 (SK2) Aux DC Output Molex 09-50-8061 (USA); Molex 09-91-0600 (UK); PINS: 08-58-0111 (SK6) Control Signals Molex 90142-0010 (USA); PINS: 90119-2110 or Amp: 87977-3, PINS: 87309-8 (SK4) Main Output Molex BB-19141-0058 Connector Kit #70-841-017, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02" (0.5mm). 3. Specifications are for convection rating at factory settings unless otherwise stated. 4. Mounting screw maximum insertion depth is 0.12". 5. Warranty: 2 years 6. Weight: 1.63 lbs/0.74 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com GLQ150 Series Installation & Operating Instructions Installation & Safety Mechanical Outline To comply with the published safety standards, the following must be observed when using this power supply: 1. Maximum ambient temperature for the power supply must not exceed 50C. 2 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03; including the requirements for creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. 3. The power supply's rated input voltage is automatically selected. Refer to the specification sheet for the input voltage range. 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 1 Output Adjust 5 SK4 3 1 5. The earth ground wire must be connected only to the point marked with the earth ground symbol (on the unit). 1 9. This power supply is 2006/95/EC. Output Connector Model GLQ152 GLQ153 GLQ154 Convection Cooling Max. Output Current (A) +5 +12 -12 +5 to +25 +5 +15 -15 +5 to +25 +5 +12 -12 15.0 6.0 2.0 2.5 15.0 4.8 1.6 2.5 15.0 6.0 2.0 +24 3.5 Max. Output Power (W) 75 with cover 110 without cover GLQ152 3 SK1 GLQ153 Inhibit +ve +12 V +15 V 4 No connection 5 Common 6 -Sense 7 +Sense 8 1, 2 30 CFM Forced Air Cooling Max. Output Current (A) 22.0 8.0 2.5 3.0 22.0 6.4 2.0 3.0 22.0 8.0 2.5 4.5 Max. Output Power (W) SK3 130 with cover 150 without cover Input Connector SK4 6 +12 V C-Share +12 V 3, 4, 5 SK2 GLQ154 Inhibit -ve 2 Output Ratings Output Voltage (V) PIN 1 marked following the provisions of the Low Voltage Directive, For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. SK2 Connector PIN Designation 7. When operating with a dc input voltage range, the unit input must be protected by a dc rated fuse in the end-use installation system. 8. The internal fuse should only be replaced with a 5 A, 250 V ac, type SP0001.1011 manufactured by Schurter AG, type 216005 manufactured by Littelfuse or type S501 manufactured by Cooper. SK1 F5AH 250V 6. Hazardous voltages exist in the primary circuits. Disconnect the power supply before servicing. 8 9 8 7 6 5 4 3 2 1 SK3 +15 V +12 V Common -12 V -15 V 7 -12 V P OK 8 +5 V to +25 V (float) +24 V 9 Common (float) Common T.B. 2 +5 V T.B. 1 Common PIN GLQ152 GLQ153 1 Earth GND 2 PIN removed 3 Line 4 PIN removed 5 Neutral GLQ154 P/N: A272-170 Rev 2 12/29/09 Ref: 03361001945 GLQ150 Series Installation & Operating Instructions Mechanical Dimensions .55 [14.0] Typical Ventilation Setup Baseplate for convection cooling and forced air cooling (0.039 in/1 mm thick sheet aluminium) 7.401 [188.0] 1.00 [25.4] 4.25 [108.0] 2.50 [63.5] 0.50 [12.7] .39 [10.0] 8.50 [216.0] 10.00 [254.0] AIR FLOW 3.14 [80.0] Bottom View .55 [14.0] POWER SUPPLY UNIT 4.25 [108.0] INPUT 1.24 [31.7] 7.401 [188.0] .75 [19.0] OUTPUT FAN .87 [22.2] 8.50 [216.0] 1.50 [38.0] 14.00 [355.6] Side View All dimensions are in inches [mm] Screw size: #6-32 For forced air cooling only Fan used: MINEBEA 3110NL-04W-B30, 12 V dc, 0.14 A Dc input for fan during testing: 12 V dc NOTE: Dimensions and fan used are for reference only GLQ152, GLQ153, and GLQ154 are commercial designations of model numbers LPQ152, LPQ153, and LPQ154 respectively. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. GLQ150 Series Specifications Electrical Specifications Input 85-132 Vac; 170-264 Vac automatically selected; 220-300 Vdc 47-63 Hz 38 A max, cold start @ 25C 75% typical at full load FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE 0878 PT3 Class B conducted Input range Frequency Inrush current Efficiency EMI filter Safety ground leakage current <0.5 mA @ 50/60 Hz, 264 Vac input Output Adjustment range 110 W convection (75 W with cover) 150 W with 30 CFM forced air (130 W with cover) 5% on main; 5-25 V on 4th output on GLQ152 & GLQ153 Cross regulation 2% on output 1; 3% on outputs 2, 3 & 4 Maximum power 20 ms @ 110 W load at nominal line Short circuit protection on all outputs Case overload protected @ 110-145% above peak rating 5.7 to 6.7 Vdc on main output Hold-up time Overload protection Overvoltage protection Minimum Load 2 A for the first output, 0.1 A for second and third outputs, 0.5 A for the 4th output of GLQ154 Logic Control Power failure TTL logic signal goes high 50-150 msec after 5 V output. It goes low at least 3 msec before loss of regulation. Requires an external TTL high signal to inhibit outputs Remote inhibit Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Environmental Specifications Operating temperature 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C Storage temperature Temperature coefficient Electromagnetic susceptibility -40C to 85C 0.04% per C Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Humidity Operating; non-condensing 5% to 95% Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75 G peak 5 Hz to 500 Hz, operational >550,000 hours at full load and 25C ambient conditions MTBF demonstrated Mating Connectors AC Input (SK4) Molex 09-50-8051 (USA) Molex 09-91-0500 (UK); PINS: 08-58-0111 Aux DC Output Molex 09-50-8091 (USA) Power Fail (SK2) Molex 09-91-0900 (UK); PINS: 08-58-0111 Remote Sense/ Molex 51110-0851 (USA) Remote Inhibit (SK1) PINS: 503-94-8100 Connector Kit #70-841-010, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02" (0.5mm). 3. Specifications are for convection rating at factory settings unless otherwise stated. 4. Remote inhibit requires an external 5 V @ 10 mA to activate. 5. Mounting (6-32) maximum insertion depth is .12". 6. Warranty: 2 years 7. Weight: 1.75 lbs/0.80 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com GLQ172 Installation & Operating Instructions Mechanical Outline To comply with the published safety standards, the following must be observed when using this power supply: 1. Maximum ambient temperature for the power supply must not exceed 50C. P252 V1 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03; including the requirements for creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. SK3 P251 V4 V3 9 3. The ac-dc input connector is approved as a component of the power supply, however, it was not specifically evaluated to IEC60320. 4. This power supply is approved and certified for the rated voltage range of 100 V ac to 250 V ac and/or 120 V dc (minimum) to 300 V dc (maximum). 5 10 1 6 SK1 SK2 5 SK4 3 1 1 5. The earth ground wire must be connected only to the point marked with the earth ground symbol (on the unit). Connector PIN Designation 6. The disconnection from the line must be in the end system. 7. When operating with a dc input voltage range, the dc source must be rectified from a mains supply not exceeding 250 V ac. The unit input must also be protected by a dc rated fuse in the end-use installation system. Output Connector 8. The internal fuse (F1) should only be replaced by a 4 A, 250 V ac, type GDA-V/S501 manufactured by Bussman, type 19194 manufactured by Wickmann, or type 226004 manufactured by Littelfuse. 9. This equipment is considered Class I according to protection against electric shock. 10. This power supply is 2006/95/EC. SK1 marked following the provisions of the Low Voltage Directive, 11. For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. SK2 Output Ratings Convection Cooling Output Voltage (V) V1: V2: V3: V4: +3.3 to +5.7 +12.0 -12.0 to -15.0 +3.3 to +25.0 +5 VSB Max. Output Current (A) 15.0 6.0 1.5 2.0 0.2 30 CFM Forced Air Cooling Max. Output Power (W) Max. Output Current (A) 110 without cover 30.0 8.0 3.0 5.0 0.2 Max. Output Power (W) SK3 Input Connector 175 with or without cover Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions SK4 PIN Designation 1 V2 SWP (Single Wire Parallel) (No connection - optional) 2 +5 VSB 3 +V2 sense (No connection - optional) 4 V1 SWP (Single Wire Parallel) 5 Common 6 +V1 sense 7 Sense common 8 Remote inhibit 9 Dc power good 10 Power fail 1,2 V2 3, 4, 5 Common 6 V3 7 P OK 8 V4 9 V4 (Return) P251 V1 P252 V1 PIN Designation 1 Earth GND 3 Line 5 Neutral P/N: A272-192 Rev 0 6/1/09 Ref: 03366202130 GLQ172 Installation & Operating Instructions Mechanical Dimensions Typical Ventilation Setup .75 [19.1] b a 1.54 [39.1] POWER SUPPLY FAN AIR FLOW .39 [9.9] 1.50 [38.1] 5.04 [128.1] MIN 30 CFM INPUT CONNECTOR 1.54 [39.1] 3.07 [78.0] Top View 3.35 [85.1] 2.50 [63.5] 2.36 [60.0] 2.11 [53.5] 4.25 [108.0] b F A N AIR FLOW MIN 30 CFM VENTILATION BOX POWER SUPPLY INPUT CONNECTOR 5.00 [127.0] a 14.37 [365.0] Side View 6.61 [168.0] 7.40 [188.0] .39 [9.9] Side View 1.77 [45.0] 6.61 [168.0] 7.40 [188.0] 30 CFM forced air cooling NOTE: Dimensions and fan used are for reference only 8.50 [216.0] Bottom View All dimensions are in inches [mm] Screw sizes: a = #6-32 (U.S.); b = M3 (International) Maximum screw protrusion: 0.6 [1.5 mm] Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. GLQ172 is a commercial designation of model number LPQ172. GLQ172 Specifications Electrical Specifications Input 85-264 Vac; 120-300 Vdc 47-67 Hz 38 A max., cold start @ 25C Input range Frequency Inrush current 75% typical at full load FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE 0878 PT3 Class B conducted 0.99 typical Efficiency EMI filter Power factor Safety ground leakage current 1.0 mA @ 50/60 Hz, 264 Vac input Output Maximum power 110 W for convection (75 W with cover); 175 W with 30 CFM forced air (130 W with cover) Adjustment range 3.3 - 5.5 V on main; -12 - 15 V on 3rd output; 3.3 - 25 V on 4th output 5 V @ 200 mA regulated 5% Standby output 20 ms @ 175 W load at nominal line Short circuit protection on all outputs Case overload protected @ 110-145% above peak rating Hold-up time Overload protection Tracks outputs 1, 3 & 4; 15 to 35% Overvoltage protection 0.5 A on 4th output Minimum load Logic Control TTL logic signal goes high 100-500 msec after V1 output. It goes low at least 4 msec before loss of regulation. Requires a contact closure to inhibit outputs Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. TTL logic signal goes high after main output is in regulation. It goes low when there is a loss of regulation. AC Power failure Remote inhibit Remote sense DC - OK Environmental Specifications Operating temperature Storage temperature 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C (except for -C version). -40C to 85C 0.4% per C Termperature coefficient Electromagnetic susceptibility Humidity Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Operating; non-condensing 5% to 95% Three orthogonal axes, sweep at 1 oct/min., 5 min. dwell at four major resonances 0.75G peak 5Hz to 500Hz, operational Vibration >550,000 hours at full load and 25C ambient conditions MTBF demonstrated Mating Connectors (SK4) AC Input Molex 09-50-8051 (USA); Molex 09-91-0500 (UK) PINS: 08-58-0111 (SK3) Main Outputs Molex 19141-0058/0063 (SK2)Aux DC Output/Power fail Molex 09-50-8091 (USA); Molex 09-91-0900 (UK); PINS: 08-58-0111 Amp: 87977-3; PINS: 87309-8 (SK1)Control Signals Molex 90142-0010 (USA); PINS: 90119-2110 or Amp: 87977-3; PINS: 87309-8 Connector Kit #70-841-015, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02" (0.5mm). 3. Specifications are for convection rating at factory settings unless otherwise stated. 4. Mounting screw maximum insertion depth is 0.12". 5. Warranty: 2 year 6. Weight: 2 lbs/0.91 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com GLQ252-C, GLQ253-C Installation & Operating Instructions Mechanical Outline To comply with the published safety standards, the following must be observed when using this power supply: 1. Maximum ambient temperature for the power supply must not exceed 50C. R10 R9 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03; including the requirements for creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. R13 R7 5 B B C37 R26 L 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. N 6 C38 R76 B 5 4 3 2 1 4th O/P Adj. R32 L O/P Adj. L11 N C42 B 3 SK4 1 2 SK7 B SK1 2 B L14 A SK2 1 1 2 L10 1 6. The disconnection from the line must be in the end system. Bus Bar L6 L4 3. The power supply's rated input voltage is automatically selected. Please refer to the specification sheet for the input voltage range. 5. The earth ground wire must be connected only to the point marked with the earth ground symbol (on the unit). A C36 C35 L16 A SK3 SK5 8 7. Hazardous voltages exist in the primary circuits. Disconnect the power supply before servicing. 8. The unit must be protected by a fuse in the end system. Components, such as capacitors, may be positioned in front of the internal fuse. 9. When operating with a dc input voltage range, the dc source must be rectified from a mains supply not exceeding 250 V ac. The unit input must also be protected by a dc rated fuse in the end-use installation system. 10. The internal fuse should only be replaced with a F6.3AH, 250 V ac, type 21606.3 manufactured by Littelfuse, type 50CF063H manufactured by Triad, or type S501 manufactured by Cooper. Connector PIN Designation Input Connector PIN SK1 1 2 3 Output Connector PIN Bus Bar 11. This equipment is considered Class I according to protection against electric shock. 12. This power supply is 2006/95/EC. marked following the provisions of the Low Voltage Directive, SK2 13. For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. Output Ratings Model GLQ252-C GLQ253-C Output Voltage (V) +5 +12 -12 +5 to +25 +5 +15 -15 +5 to +25 SK3 30 CFM Forced Air Cooling (unit not convection rated) Max. Output Current (A) 35.0 10.0 6.0 6.0 35.0 10.0 6.0 6.0 Max. Output Power (W) SK4 250 with cover Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions SK5 SK7 A B 1 2, 3 4 5 6 1 2 3 4 5 6 7 8 1 GLQ252-C GLQ253-C Neutral Line Earth GND GLQ252-C GLQ253-C +5 V Common +12 V +15 V Common -12 V -15 V Return (float) +5 V to +25 V adj. (float) +Sense -Sense Inhibit (normally open) Inhibit (normally closed) Common Active current share P OK Dc OK Fan (+) 2 Fan (-) 1 2 +5 V (aux) Common 1 Fan (+) 2 Fan (-) P/N: A272-194 Rev 0 6/4/09 Ref: 03361002202 GLQ252-C, GLQ253-C Installation & Operating Instructions Mechanical Dimensions Typical Ventilation Setup 2.01 [51.0] max. with cover 1.87 [47.5] max. a a 9.00 [228.6] BASEPLATE (0.039 in/1mm THK. SHEET ALUMINIUM) 1.18 [30.0] 8.52 [216.4] .24 [6.1] .59 [15.0] 2.50 [63.5] SK1 Side View 10.00 [254.0] POWER SUPPLY UNIT 5.00 [127.0] AIR FLOW a b b F A N .50 [12.7] a 1.71 [43.5] 5.00 [127.0] 2.50 [63.5] 14.00 [355.6] 2.50 [63.5] 1.71 [43.5] 1.77 [45.0] 5.46 [138.6] a 1.18 [30.0] b b a Fan Used: Minebea 2410ML-04W-B60, 12 V dc, 0.40 A Dc Input for Fan Testing: 12 V dc NOTE: Dimensions and fan used are for reference only 6.64 [168.6] 9.00 [228.6] Bottom View All dimensions are in inches [mm] Screw sizes: a = #6-32 (U.S.); b = M3 (International) Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. GLQ252-C and GLQ253-C are commercial designations of model numbers LPQ252 and LPQ253 respectively. GLQ250 Series Specifications Electrical Specifications Input Input range Frequency Inrush current Efficiency EMI filter 85-264 Vac; 120-300 Vdc 47-440 Hz 20 A max, cold start @ 25C 75% typical at full load FCC Class B conducted and radiated; CISPR 22 Class B conducted and radiated; EN55022 Class B conducted and radiated; VDE 0878 PT3 Class B conducted and radiated Safety ground leakage current <0.5 mA @ 50/60 Hz, 264 Vac input Output With cover: 250 W with 30 CFM forced air, (-C) (-CF) (CEF) Maximum power Adjustment range 5% min. on main: 5-25 V on 4th output Supervisory outputs 5 V @ 100 mA regulated, 12 V @ 500 mA 16 ms @ 250 W load, 115 Vac nominal line Short circuit protection on all outputs. Case overload protected @ 110-145% above peak rating 5 V output: 5.7 to 6.7 Vdc; Other models 10% to 25% above nominal output Hold-up time Overload protection Overvoltage protection 3 A for 1st output Minimum load Logic Control Power failure TTL logic signal goes high 50-150 msec after 5 V output. It goes low at least 4 msec before loss of regulation Remote on/off Requires an external contact (N.O. or N.C.) to inhibit outputs TTL logic goes high 50-150 msec after the output. It goes low when there is loss of regulation DC-OK Compensates for 0.5 V lead drop minimum, will operate without remote sense connected. Reverse connection protected. Remote sense Environmental Specifications Operating temperature 0 to 50C ambient. Derate each output at 2.5% per degree from 50 to 70C Storage temperature Temperature coefficient Electromagnetic susceptibility Humidity -40C to 85C 0.4% per C Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Operating; non-condensing 5% to 95% Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.7 G peak 5Hz to 500Hz, operational Vibration >550,000 hours at full load and 25C ambient conditions MTBF demonstrated Mating Connectors SK3 SK4 SK5 SK7 Molex 22-01-1084 PINS: 08-70-0057 Molex 22-01-3027 PINS: 08-50-0114 Molex 22-01-3027 PINS: 08-50-0114 Molex 22-01-3027 PINS: 08-50-0114 Connector Kit #70-841-005, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02". 3. Specifications are at factory settings unless otherwise stated. 4. To enable normally closed remote inhibit, cut jumper J1. 5. Mounting maximum insertion depth is 0.12". 6. Warranty: 2 year 7. Weight: 3.1 lbs/1.41 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com GLQ352-C, GLQ352-CEF Installation & Operating Instructions Mechanical Outline To comply with the published safety standards, the following must be observed when using this power supply: 1. Maximum ambient temperature for the power supply must not exceed 50C. A Bus B Bar 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03; including the requirements for creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. Top Pot = V4 adj. Bottom Pot = Main adj. 3. The power supply's rated input voltage is automatically selected. Please refer to the specification sheet for the input voltage range. 3 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 1 5. This unit contains a secondary output exceeding 240 VA. When installing the unit into the end system, make sure the secondary output and the appropriate wire cannot be touched. 6. The earth ground wire must be connected only to the point marked with the earth ground symbol (on the unit). Input Connector PIN Designation SK1 1 2 3 Neutral Line Earth GND Output Connector PIN Designation A B 1 2 3 4 +5 V Common +12 V Common Common -12 V Bus Bar 9. When operating with a dc input voltage range, the unit input must be protected by a dc rated fuse in the end-use installation system. 10. The internal fuse should only be replaced with a F10AH, 250 V ac, type 216010 manufactured by Littelfuse or type SP001.1014 manufactured by Schurter AG. SK2 11. This equipment is considered Class I according to protection against electric shock. 12. This power supply is 2006/95/EC. marked following the provisions of the Low Voltage Directive, 13. For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. SK3 Output Ratings 30 CFM Forced Air Cooling (unit not convection rated) Model Output Voltage (V) Max. Output Current (A) GLQ352-C (-CEF) +5 +12 -12 +3.3 to +24 50.0 12.0 6.0 6.0 SK4 Max. Output Power (W) SK5 350 with cover Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions SK2 1 SK3 10 Connector PIN Designation 7. The disconnection from the line must be in the end system. 8. Hazardous voltages exist in the primary circuits. Disconnect the power supply before servicing. SK6 SK4 SK5 SK1 2 6 5 4 3 2 1 SK6 5 Return (float) 6 1 2 3 4 5 6 7 8 9 10 1 +3.3 V to +24 V adj. +Sense V4 -Sense V4 +Sense V1 -Sense V1 P OK C. Share Dc OK Inhibit Inhibit Common +12 V (aux) 2 Common 1 +5 V (aux) 2 Common 1 12 V fan (+) 2 Fan (-) P/N: A272-195 Rev 0 5/6/09 Ref: 03366200121 GLQ352-C, GLQ352-CEF Installation & Operating Instructions Mechanical Dimensions 2.42 [61.4] Typical Ventilation Setup 6.65 [168.6] 9.00 [228.6] .59 [15.0] 2.50 [63.5] BASEPLATE (0.039 in/1mm THK. SHEET ALUMINIUM) 1.71 [43.5] 2.48 [63.0] SK1 1.71 [43.5] 10.00 [254.0] 0.65 [16.5] POWER SUPPLY UNIT 5.00 [127.0] AIR FLOW 1.12 [28.5] Bottom View F A N .50 [12.7] 10.24 [260.0] 2.50 [63.5] 14.00 [355.6] 5.00 [127.0] Fan Used: Minebea 2410ML-04W-B60, 12 V dc, 0.40 A Dc Input for Fan Testing: 12 V dc NOTE: Dimensions and fan used are for reference only NOTE: Not applicable for -CEF models 1.40 [35.5] 2.00 [50.9] Top View 3.29 [83.5] 1.18 [30.0] 0.20 [5.0] 1.48 [37.5] 8.52 [216.4] Side View All dimensions are in inches [mm] Screw Size: a = #6-32 (U.S.); b = M3 (International) Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions. GLQ352-C and GLQ352-CEF are commercial designations of model number LPQ352 respectively. (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. GLQ352 Series Specifications Electrical Specifications Input Input range Frequency Inrush current Efficiency EMI filter Power factor Safety ground leakage current 85-264 Vac; 120-300 Vdc 47-440 Hz 38 A max, cold start @ 25C 75% typical at full load FCC Class B conducted and radiated; CISPR 22 Class B conducted and radiated; EN55022 Class B conducted and radiated; VDE 0878 PT3 Class B conducted and radiated 0.99 typical <0.5 mA @ 50/60 Hz, 264 Vac input Output With cover: 350 W with 30 CFM forced air, (-C) (-CF) (-CEF) Maximum power Adjustment range 5% min. on main: 3.3-24 V on output 4 Supervisory output 5 V @ 500 mA regulated, 12 @ 150 mA x2 20 ms @ 350W load, 115 Vac nominal line Short circuit protection on all outputs. Case overload protected @ 110-145% above peak rating 5 V output: 5.7 to 6.7 Vdc Hold-up time Overload protection Overvoltage protection Minimum load 5 A for 1st output; 1 A for 4th output (minimum load required when the output is set below 5 V) Logic Control Power failure TTL logic signal goes high 50-150 msec after 5 V output. It goes low at least 4 msec before loss of regulation Remote on/off Requires an external contact (N.O. or N.C.) to inhibit outputs TTL logic goes high 50-150 msec after 5 V output. It goes low when there is loss of regulation. DC-OK Compensates for 0.5 V lead drop minimum, will operate without remote sense connected. Reverse connection protected Remote sense Environmental Specifications Operating temperature 0 to 50C ambient. Derate each output at 2.5% per degree from 50 to 70C Storage temperature Temperature coefficient Electromagnetic susceptibility Humidity -40C to 85C 0.04% per C Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Operating; non-condensing 5% to 95% Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.7 G peak 5Hz to 500Hz, operational Vibration MTBF demonstrated >550,000 hours at full load and 25C ambient conditions Mating Connectors SK3 SK4 SK5 SK6 Molex 22-01-1084 PINS: 08-70-0057 Molex 22-01-3027 PINS: 08-50-0114 Molex 22-01-3027 PINS: 08-50-0114 Molex 22-01-3027 PINS: 08-50-0114 Connector Kit #70-841-011, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02". 3. Specifications are at factory settings unless otherwise stated. 4. To enable normally closed remote inhibit, cut jumper J1. 5. Mounting (6-32) maximum insertion depth is .12". 6. Warranty: 1 year 7. Weight: 4 lbs/1.8 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com GLS100-M Series Installation & Operating Instructions Output Ratings To comply with the published safety standards, the following must be observed when using this power supply: 1. Maximum ambient temperature for the power supply must not exceed 50C. Derate each output 2.5% per degree from 50C to 70C ambient temperature. 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, CSA22.2 No. 60950-1-03, UL60601-1, EN60601-1, IEC60601-1, and CSA22.2 No. 601.1. The safety requirements include creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. Model Output Voltage (V) GLS102-M GLS103-M GLS104-M 3. The ac-dc input connector is approved as a component of the power supply, however, it was not specifically evaluated to IEC60320. GLS105-M 4. This power supply is approved and certified for the rated voltage range of 100 V ac to 250 V ac and/or 120 V dc minimum to 300 V dc maximum. GLS108-M +5 16.0 +12_fan 0.5 7. The disconnection from the line must be in the end system. 8. Hazardous voltages exist in the primary circuits. Disconnect power supply before servicing. 8.3 1.0 +15 6.7 10.0 +12_fan 0.5 +24 4.2 100 1.0 6.25 0.5 1.0 +48 2.09 3.1 +12_fan 0.5 1.0 PIN Designation 1 Neutral 3 CN1 Output Connector 120 150 Line GND PIN Designation 1 2 3 SK2 Common 4 5 7 +Vout 8 SK203 marked following the provisions of the Low Voltage Directive, Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions Max. Output Power (W) 12.5 +12_fan SK1 11. The power supply has no patient applied part. 14. For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. 1.0 0.5 6 13. This power supply is 2006/95/EC. 24.0 +12 Input Connector NOTE: The power supply has a fuse on the neutral line. 12. This equipment is considered Class I according to protection against electric shock. 80 30 CFM Forced Air Cooling Max. Output Current (A) Connector PIN Designation 9. When operating with a dc input voltage range, the unit input must be protected by a dc rated fuse in the end-use installation system. 10. The internal fuses (F1 & F2) should only be replaced with a F2A5, 250 V ac, type 392 manufactured by Wickmann or type RST manufactured by Belfuse. Max. Output Power (W) +12_fan 5. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 6. The earth ground wire must be connected only to the point marked with the earth ground symbol (on the unit). Convection Cooling Max. Output Current (A) SK5 1 GND 2 Power fail 3 -Remote sense 4 +Remote sense 1 +12 V_fan 2 +12 V_fan 3 Common fan 4 Common fan P/N: A272-196 Rev 0 5/7/09 Ref: 03366206070 GLS100-M Series Installation & Operating Instructions Mechanical Outline & Dimensions VR1 Output Voltage Adjust Pot M1 M2 SK1 3 2.00 [50.8] 4 1 1.29 [33.0] SK5 1 8 7 6 5 SK2 4 3 2 1 1.72 [43.8] 4 SK203 0.16 [4.0] 1 CN1 3.73 [94.7] 4.00 [101.6] Top View 0.197 [5.0] Minimum standoff height Side View All dimensions are in inches [mm] Mounting hole diameter (4X) = 0.16 [4.0 mm] Maximum screw head diameter = 0.22 [5.6 mm] Mounting holes M1 and M2 should be grounded for EMI purposes Mounting hole M1 is a safety ground connection Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions. GLS102-M, GLS103-M, GLS104-M, GLS105-M, and GLS108-M are commercial designations of model numbers LPS102-M,LPS103-M, LPS104-M, LPS105-M, and LPS108-M respectively. (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. GLS100-M Series Specifications Electrical Specifications Input Input range 90-264 Vac; 120-300 Vdc Frequency 47-63 Hz 50 A max., cold start @ 25C Inrush current 88% typical at full load FCC Class B conducted; CISPR22 Class B conducted; EN55022 Class B conducted; VDE 0878 PT3 Class B conducted Efficiency EMI/RFI Safety ground leakage current 275 A @ 50/60 Hz, 264 Vac input Output Maximum power 100 W for convection (80 W for GLS102-M); 150 W with 30 CFM forced air (120 W for GLS102-M) Adjustment range 10% min. on the main outputs 12 V @ 1 A isolated, 10% Fan output 10 ms @ 150 W load, 120 Vac input Short circuit protection on all outputs Case overload protected @ 110-160% above rating Hold-up time Overload protection 15% to 35% above nominal output Overvoltage protection Logic Control Open collector logic signal goes high 100-500 msec after main output. It goes low at least 6 msec before loss of regulation. Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Power failure Remote sense Environmental Specifications Operating temperature Storage temperature Electromagnetic susceptibility Humidity 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C. -20C start up -40C to 85C Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Operating; non-condensing 10% to 95% RH IEC68-2-6 to the levels of IEC721-3-2 Vibration >550,000 hours at full load and 25C ambient conditions MTBF demonstrated Mating Connectors (SK1) AC Input Molex P/N: 09-50-8031, PINS: 08-52-0113 or Landwin P/N: 3060S0302, PINS: 3360T011P AC Ground Molex: 01-90020001 (SK2) DC Molex P/N: 09-50-8081, PINS: 08-52-0113 or Landwin P/N: 3060S0802, PINS: 3360T011P Outputs (SK203) Remote Molex P/N: 35155-0400, PINS: 08-70-0057 or Landwin P/N: 2640S04A0, PINS: 2543T011P Sense (SK5) Fan Molex P/N: 22-01-1042, PINS: 08-70-0049 or Landwin P/N: 2510S04A0, PINS: 2543T011P Connector Kit #70-841-025, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02" (0.5mm). 3. Specifications are for convection rating at factory settings at 115 Vac input 25C unless otherwise stated. 4. 5. 6. 7. 8. Mounting holes MH1 and MH2 should be grounded for EMI purposes. Mounting hole MH1 is safety ground connection. This power supply requires mounting on metal standoffs 0.20" (5 m) in height. Warranty: 2 year Weight: 0.44 lb/0.20 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com GLS110 Series Installation & Operating Instructions Mechanical Outline & Dimensions To comply with the published safety standards, the following must be observed when using this power supply: .25 [6.35] 1. Maximum ambient temperature for the power supply must not exceed 50C. 3. The power supply's rated input voltage is automatically selected. Please refer to the specification sheet for the input voltage range. SK201 SK202 1 V Adj. 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 234-M90; including the requirements for creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. 4.00 [101.6] 3.50 [88.9] 9 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 5. The earth ground wire must be connected only to the point marked with the earth ground symbol (on the unit). SK2 1 3 5 SK1 6.50 [165.1] .25 [6.35] 6. Hazardous voltages exist in the primary circuits. Disconnect the power supply before servicing. 7.00 [177.8] 7. When operating with a dc input voltage range, the dc source must be rectified from a mains supply not exceeding 250 V ac. The unit input must also be protected by a dc rated fuse in the end-use installation system. 8. The internal fuse should only be replaced with a 4 A, 250 V ac, Type SP0001.1010 manufactured by Schurter AG, Type 216004 manufactured by Littelfuse or Type S501 manufactured by Cooper. Connector PIN Designation Input Connector PIN SK1 1 3 5 Output Connector PIN SK2 1 2 3 4 5 6 7 8 9 9. This equipment is considered Class I according to protection against electric shock. 10. This power supply is 2006/95/EC. marked following the provisions of the Low Voltage Directive, 11. For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. Output Ratings Convection Cooling Model Output Voltage (V) Calculated Max. Output Current (A) GLS114 +15 5.3 GLS115 +24 3.3 Max. Output Power (W) 80 30 CFM Forced Air Cooling Max. Output Current (A) 7.3 4.6 Max. Output Power (W) 110 Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions SK201 SK202 GLS114 GLS115 GND Neutral Line GLS114 GLS115 +15 V +24 V Common +15 V +24 V 1 +Sense 2 -Sense 1 P OK 2 GND P/N: A272-200 Rev 0 5/13/09 Ref: 03361001612 GLS110 Series Installation & Operating Instructions Mechanical Dimensions Typical Ventilation Setup Bottom View with Optional L-Bracket Top View 1.37 [35] 1.37 [35] AC INPUT CONNECTOR 4.28 [108.6] 6.50 [165] 2.50 [63.5] AIR FLOW FAN POWER SUPPLY UNIT 1.37 [35] 1.37 [35] 4.13 [105] .98 [25] 8.07 [205] 18.89 [480] .59 [15] 6.40 [162.6] 7.30 [185.5] AIR FLOW FAN 4.72 [120] Side View with Optional L-Bracket 1.96 [50] POWER SUPPLY UNIT .19 [5] .59 [15] Side View 2.20 [56.0] Fan Used: MINEBEA 3610NL-04W-B30, 12 V dc, 0.23 A Dc Input for Fan During Testing: 12 V dc NOTE: Dimensions and fan used are for reference only .86 [21.8] 5.90 [150.0] All dimensions are in inches [mm] Screw size: #6-32 Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. GLS114 and GLS115 are commercial designations of model numbers LPS114 and LPS115 respectively. GLS110 Series Specifications Electrical Specifications Input Input range 85-264 Vac; 120-300 Vdc Frequency 47-440 Hz Inrush current <18 A peak @ 115 Vac; <36 A peak @ 230 Vac, cold start @ 25C Input current 2.5 A max. (RMS) @ 115 Vac 70% typical at full load Meets FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE 0878 PT3 Class B conducted Efficiency EMI filter Safety ground leakage current <0.5 mA @ 50/60 Hz, 264 Vac input Output Maximum power 80 W for convection; 110 W with 30 CFM forced air Adjustment range 5% min. 20 ms @ 80 W load, 115 Vac nominal line Short circuit protection on all outputs Case overload protected @ 110-145% above peak rating Hold-up time Overload protection Overvoltage protection 5 V output; 5.7 to 6.7 Vdc; Other outputs 10% to 20% above nominal output; Latching type, recycle AC to reset Logic Control TTL logic signal goes high 50-150 msec after main output. It goes low at least 4 msec before loss of regulation. Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Power failure Remote sense Environmental Specifications Operating temperature Storage temperature 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C -40C to 85C Temperature coefficient Electromagnetic susceptibility Humidity 0.04% per C Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Operating; non-condensing 5% to 95% Three orthogonal axes, sweep at 1 oct/min., 5 min. dwell at four major resonances 0.75G peak 5Hz to 500Hz, operational Vibration >550,000 hours at full load and 25C ambient conditions MTBF demonstrated Mating Connectors AC Input Molex 09-50-8051 (USA) 09-91-0500 (UK); PINS: 08-58-0111 DC Outputs Molex 09-50-8091 (USA) 09-91-0900 (UK); PINS: 08-58-0111 Remote Sense/ Molex 22-01-1022 (USA) Power Fail 22-01-1023 (UK); PINS: 08-50-0114 Connector Kit #70-841-007, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02" (0.5mm). 3. Specifications are for convection rating at factory settings unless otherwise stated. 4. 5. 6. 7. 8. Mounting holes M1 and M2 should be grounded for EMI purposes. Mounting hole M1 is safety ground connection. L bracket mounting (6-32) maximum insertion depth is .20". Warranty: 2 year Weight: 1.25 lbs/0.57 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com GLS120 Series Installation & Operating Instructions Mechanical Outline To comply with the published safety standards, the following must be observed when using this power supply: 1. Maximum ambient temperature for the power supply must not exceed 50C. Derate each output 2.5% per degree from 50C to 70C ambient temperature. 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03; including the requirements for creepage distances, clearances and distance through insulation between primary wiring and earth or secondary (SELV) wiring. 3. The ac-dc input connector is approved as a component of the power supply, however, it was not specifically evaluated to IEC60320. 4. This power supply is approved and certified for the rated voltage range of 100 V ac to 250 V ac and/or 120 V dc (minimum) to 300 V dc (maximum). V Adj. Pot CN1 N 7. The disconnection from the line must be in the end system. 8. Hazardous voltages exist in the primary circuits. Disconnect power supply before servicing. 1 P1 9 10 Connector PIN Designation Input Connector PIN Designation Neutral Line Earth Designation Common Main output +Power fail +5 VSTBY -Remote inhibit +12 V common +Remote inhibit +12 V (FAN_OUT) -Remote sense SWP (Single wire parallel) +Remote sense Common CN1 P1 Output Connector SKSK+ PIN 1 2 3 4 5 6 7 8 9 10 SK3 11. This equipment is considered Class I according to protection against electric shock. 12. This power supply is 2006/95/EC. 2 SK3 9. When operating with a dc input voltage range, the dc source must be rectified from a mains supply not exceeding 250 V ac. The unit input must also be protected by a dc rated fuse in the end-use installation system. 10. The internal fuse (F1) should only be replaced by a 4AH, 250 V ac, type GDA-V/S501 manufactured by Bussmann, type 216004.MXEP manufactured by Littelfuse, or type 19194 manufactured by Wickmann. SK+ L 5. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 6. The earth ground wire must be connected only to the point marked with the earth ground symbol (on the unit). SK- marked following the provisions of the Low Voltage Directive, 13. For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. Output Ratings Model GLS122 GLS123 Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions Output Voltage (V) +5 +12 (fan_out) +5 VSTBY +12 +12 (fan_out) +5 VSTBY Convection Cooling Max. Output Current (A) 16.0 0.5 0.5 6.7 0.5 0.5 30 CFM Forced Air Cooling Max. Output Power (W) Max. Output Current (A) Max. Output Power (W) 80 26.0 0.5 0.5 10.8 0.5 0.5 130 P/N: A272-190 Rev 0 5/1/09 Ref: 03366202940/LPS123/OP GLS120 Series Installation & Operating Instructions Mechanical Dimensions Typical Ventilation Setup Option 1 5.00 [127.0] 4.55 [115.6] 3.15 [80.0] 3.00 [76.2] F AIR FLOW A N POWER SUPPLY 1.32 [33.5] 2.55 [64.8] .49.08 [12.42.00] 4.00.08 [101.82.00] Top View Top View Option 2 F AIR FLOW 3.15 [80.0] A N POWER SUPPLY 1.26 [32.0] 1.32 [33.5] .39.08 [10.02.00] 4.00.08 [101.82.00] Top View Side View Cooling Fan: Use one 12 V dc fan or equivalent with minimum 30 CFM blowing lengthwise or sideways NOTE: Dimensions and fan used are for reference only All dimensions are in inches [mm] Mounting hole diameter (4X): 0.15 [3.81 mm] Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions. GLS122 and GLS123 are commercial designations of model numbers LPS122 and LPS123 respectively. (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. GLS120 Series Specifications Electrical Specifications Input 85-264 Vac; 127-300 Vdc 47-440 Hz 40 A max., cold start @ 25C Input range Frequency Inrush current 80% typical at full load FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE 0878 PT3 Class B conducted 0.99 typical Efficiency EMI/RFI Power factor Safety ground leakage current <0.5 mA @ 50/60 Hz, 264 Vac input Output Maximum power 80 W for convection; 130 W with 30 CFM forced air Adjustment range 5% min. on the main outputs 12 V @ 500 mA - 5%, +7% Fan output 5 V @ 500 mA 5% Standby outputs 20 ms @ 125 W load, 120 Vac input Short circuit protection on all outputs Case overload protected @ 120-135% above rating Hold-up time Overload protection 20% to 35% above nominal output Overvoltage protection Logic Control TTL logic signal goes high 100-500 msec after main output. It goes low at least 4 msec before loss of regulation. Requires a contact closure to disable the outputs, except 5 V standby. Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Power failure Remote inhibit Remote sense Environmental Specifications Operating temperature Storage temperature Electromagnetic susceptibility Humidity 0 to 50C ambient. Derate each output as 2.5% per degree from 50 to 70C. -20C start up -40C to 85C Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Operating; non-condensing 10% to 95% RH IEC68-2-6 to the levels of IEC721-3-2 Vibration >550,000 hours at full load and 25C ambient conditions MTBF demonstrated Mating Connectors (SK1) AC Input Molex 09-50-8031; PINS: 08-52-0113 (SK2) DC Outputs Molex 19141-0058/0063 Spade lug (SK3)Control Signals Molex 90142-0010 (USA); PINS: 90119-2110 or Amp: 87977-3; PINS: 87309-8 Connector Kit #70-841-020, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02" (0.5mm). 3. Specifications are for convection rating at factory settings at 115 Vac input 25C ,unless otherwise stated. 4. 5. 6. 7. 8. Mounting holes MH1, MH2 and MH3 should be grounded for EMI purposes. Mounting MH1 is safety ground connection. This power supply requires mounting on metal standoffs 0.20" (5m) in height. Warranty: 2 year Weight: 0.71 lb/0.32 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com GLS150 Series Installation & Operating Instructions Installation & Safety Mechanical Outline To comply with the published safety standards, the following must be observed when using this power supply: 1. Maximum ambient temperature for the power supply must not exceed 50C. 2 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03; including the requirements for creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. 1 3. The power supply's rated input voltage is automatically selected. Please refer to the specification sheet for the input voltage range. Output Adjust 5 SK4 3 1 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 1 6. Hazardous voltages exist in the primary circuits. Disconnect the power supply before servicing. SK1 F5AH 250V 5. The earth ground wire must be connected only to the point marked with the earth ground symbol (on the unit). Output Connector PIN GLS152 GLS153 1 Inhibit -ve 2 Inhibit +ve 8. The internal fuse should only be replaced with a 5 A, 250 V ac, type SP0001.1011 manufactured by Schurter AG, type 216005 manufactured by Littelfuse or type S501 manufactured by Cooper. 3 Secondary Vcc 4 No connection 5 Common SK1 marked following the provisions of the Low Voltage Direc- For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. SK2 6 -Sense 7 +Sense 8 C-Share 1, 2, 3, 4, 8, 9 Not used 5 Common 6 No connection 7 Output Ratings Model Output Voltage (V) Convection Cooling Max. Output Current (A) GLS152 +5 22.0 GLS153 +12 to +15 9.1 GLS155 +24 to +28 4.5 Max. Output Power (W) 75 with cover 110 without cover SK3 30 CFM Forced Air Cooling Max. Output Current (A) 30.0 12.5 6.2 Input Connector Max. Output Power (W) 130 with cover 150 without cover SK2 Connector PIN Designation 7. When operating with a dc input voltage range, the unit input must be protected by a dc rated fuse in the end-use installation system. 9. This power supply is tive, 2006/95/EC. 8 9 8 7 6 5 4 3 2 1 SK3 SK4 T.B. 2 P OK +5 V T.B. 1 PIN GLS155 +12 V to +15 V +24 V to +28 V Common GLS152 GLS153 1 Earth GND 2 PIN removed 3 Line 4 PIN removed 5 Neutral GLS155 P/N: A272-169 Rev 2 12/29/09 Ref: 03361001994 GLS150 Series Installation & Operating Instructions Mechanical Dimensions .55 [14.0] Typical Ventilation Setup Baseplate for convection cooling and forced air cooling (0.039 in/1 mm thick sheet aluminium) 7.401 [188.0] 1.00 [25.4] 4.25 [108.0] 2.50 [63.5] 0.50 [12.7] .39 [10.0] 10.00 [254.0] 8.50 [216.0] AIR FLOW 3.14 [80.0] Bottom View .55 [14.0] POWER SUPPLY UNIT 4.25 [108.0] INPUT 1.24 [31.7] 7.401 [188.0] .75 [19.0] OUTPUT FAN .87 [22.2] 8.50 [216.0] 1.50 [38.0] 14.00 [355.6] Side View All dimensions are in inches [mm] Screw size: #6-32 For forced air cooling only Fan used: MINEBEA 3110NL-04W-B30, 12 V dc, 0.14 A Dc input for fan during testing: 12 V dc NOTE: Dimensions and fan used are for reference only GLS152, GLS153, and GLS155 are commercial designations of model numbers LPS152, LPS153, and LPS155 respectively. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. GLS150 Series Specifications Electrical Specifications Input Input range 85-132 Vac; 170-264 Vac automatically selected; 220-300 Vdc Frequency 47-63 Hz 38 A max, cold start @ 25C Inrush current 75% typical at full load FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE 0878 PT3 Class B conducted Efficiency EMI filter Safety ground leakage current <0.5 mA @ 50/60 Hz, 264 Vac input Output 110 W convection (75 W with cover) 150 W with 30 CFM forced air (130 W with cover) 5% min. Maximum power Adjustment range 20 ms @ 110 W load, 115/230 Vac nominal line Short circuit protection Case overload protected @ 110-145% above peak rating 5 V output: 5.7 to 6.7 Vdc; Other outputs 10% to 25% above nominal output Hold-up time Overload protection Overvoltage protection Logic Control Power failure TTL Logic signal goes high 50-150 msec after 5 V output. It goes low at least 3 ms before loss of regulation Requires an external TTL high signal to inhibit outputs Remote inhibit Remote sense Compensates for 0.5 V lead drop minimum, will operate without remote sense connected. Reverse connection protected Environmental Specifications Operating temperature 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C Storage temperature Temperature coefficient Electromagnetic susceptibility -40C to 85C 0.04% per C Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Humidity Operating; non-condensing 5% to 95% Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5 Hz to 500 Hz, operational >550,000 hours at full load and 25C ambient conditions MTBF demonstrated Mating Connectors AC Input (SK4) Molex 09-50-8051 (USA) Molex 09-91-0500 (UK); PINS: 08-58-0111 Power Fail (SK2) Molex 09-50-8031 (USA) Molex 09-91-0300 (UK); PINS: 08-58-0111 Remote Sense/ Molex 51110-0851 (USA) Remote Inhibit (SK1) PINS: 50394-8100 Connector Kit #70-841-009, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02" (0.5mm). 3. Specifications are for convection rating at factory settings unless otherwise stated. 4. Remote inhibit requires an external 5 V @ 10 mA to activate. 5. Mounting (6-32) maximum insertion depth is .12". 6. Warranty: 2 year 7. Weight: 1.75 lbs/0.80 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com GLS170 Series, GLS170-M Series Installation & Operating Instructions Output Ratings To comply with the published safety standards, the following must be observed when using this power supply: Convection Cooling 1. Maximum ambient temperature for the power supply must not exceed 50C. Derate each output 2.5% per degree from 50C to 70C ambient temperature for GLS174 and GLS175. 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03 for GLS172, GLS173, GLS174, and GLS175; UL60601-1, EN60601-1, IEC60601-1, and CSA22.2 No. 60601-1-M90 for GLS172-M, GLS173-M, GLS174-M, and GLS175-M. The safety requirements include creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. 3. The ac-dc input connector is approved as a component of the power supply, however, it was not specifically evaluated to IEC60320. Output Voltage (V) Model GLS172 (-M) GLS173 (-M) GLS174 (-M) 4. This power supply is approved and certified for the rated voltage range of 100 V ac to 250 V ac and/or 120 V dc (minimum) to 300 V dc (maximum). 5. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. GLS175 (-M) Max. Output Current (A) 30 CFM Forced Air Cooling Max. Output Power (W) Max. Output Current (A) +2.5 to +6 22.0 without cover 15.0 with cover 35.0 +5 VSTBY 1.0 2.0 +12 (fan_out) 0.5 1.0 +6 to +12 9.1 without cover 6.25 with cover 15.0 +5 VSTBY 1.0 +12 (fan_out) 0.5 +12 to +24 7.3 without cover 5.33 with cover +5 VSTBY 1.0 2.0 +12 (fan_out) 0.5 1.0 +24 to +54 4.58 without cover 3.125 with cover 7.5 Max. Output Power (W) 175 with and without cover 2.0 110 without cover 75 with cover 1.0 12.0 +5 VSTBY 1.0 2.0 +12 (fan_out) 0.5 1.0 180 with and without cover 6. The disconnection from the line must be in the end system. 7. Hazardous voltages exist in the primary circuits. Disconnect power supply before servicing. 8. When operating with a dc input voltage range, the unit input must be protected by a dc rated fuse in the end-use installation system. 9. The internal fuse (F1) should only be replaced by a 4A, 250 V ac, type GDA-V/S501 manufactured by Bussmann, type 226004 manufactured by Littelfuse, or type 19194 manufactured by Wickmann. Connector PIN Designation Input Connector SK4 Output Connector 10. The power supply has no patient applied part. PIN Designation 1 Earth GND 3 Line 5 Neutral PIN Designation 1 +12 V (fan_out) 2 +5 VSTBY 11. This equipment is considered Class I according to protection against electric shock. 3 Common 12. This power supply is 2006/95/EC. 4 V1 SWP (Single wire parallel) marked following the provisions of the Low Voltage Directive, SK1 13. For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. SK3 Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions 5 Common 6 +V1 sense 7 Sense common 8 Remote inhibit 9 DC OK 10 P OK TB-1 Common TB-2 V1 P/N: A272-191 Rev 0 3/13/09 Ref: 03366202050/LPS173/OP/03366202230/03366202241 GLS170 Series, GLS170-M Series Installation & Operating Instructions Mechanical Outline & Dimensions Typical Ventilation Setup TB-1 1.54 [39.1] SK3 POWER SUPPLY FAN AIR FLOW .39 [9.9] TB-2 5.04 [128.1] MIN 30 CFM 10 1 5 6 3 Voltage Adj. Pot 1 3.07 [78.0] SK1 Top View 3.35 [85.1] 2.36 [60.0] a F A N AIR FLOW MIN 30 CFM VENTILATION BOX POWER SUPPLY INPUT CONNECTOR .75 [19.1] b 1.50 [38.1] 5.00 [127.0] 14.37 [365.0] Side View 6.61 [168.0] 7.40 [188.0] 1.77 [45.0] SK4 INPUT CONNECTOR 1.54 [39.1] .39 [9.9] 5 30 CFM forced air cooling NOTE: Dimensions and fan used are for reference only Side View a b 2.11 [53.5] 2.50 [63.5] 4.25 [108.0] a b 6.61 [168.0] 7.40 [188.0] 8.50 [216.0] Bottom View All dimensions are in inches [mm] Screw Size: a = #6-32 (U.S.); b = M3 (International) Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions. GLS172, GLS173, GLS174, and GLS175 are commercial designations of model numbers LPS172, LPS173, LPS174, and LPS175 respectively. GLS172-M, GLS173-M, GLS174-M, and GLS175-M are commercial designations of model numbers LPS172-M, LPS173-M, LPS174-M, and LPS175-M respectively. (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. GLS170 Series Specifications Electrical Specifications Input 85-264 Vac; 120-300 Vdc 47-63 Hz 38 A max., cold start @ 25C Input range Frequency Inrush current 75% typical at full load FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE 0878 PT3 Class B conducted 0.99 typical Efficiency EMI filter Power factor Safety ground leakage current 1.0 mA @ 50/60 Hz, 264 Vac input Output Maximum power 110 W for convection (75 W with cover); 175 W with 30 CFM forced air (130 W with cover) Adjustment range 2:1 wide ratio minimum 5 V @ 2 A regulated 5% Standby output 20 ms @ 175 W load at nominal line Short circuit protection on all outputs Case overload protected @ 110-145% above peak rating Hold-up time Overload protection 10% to 40% above nominal output Overvoltage protection 12 V @ 1 A -5%, +10% Aux output Logic Control TTL logic signal goes high 100-500 msec after V1 output. It goes low at least 4 msec before loss of regulation. Requires contact closure to inhibit outputs Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. TTL logic signal goes high after main output is in regulation. It goes low when there is a loss of regulation. Power failure Remote inhibit Remote sense DC - OK Environmental Specifications 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C. -20C Operating temperature Low temperature start Storage temperature -40C to 85C Termperature coefficient Electromagnetic susceptibility Humidity 0.4% per C Designed to meet IEC EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Operating; non-condensing 5% to 95% Three orthogonal axes, sweep at 1 oct/min., 5 min. dwell at four major resonances 0.75G peak 5Hz to 500Hz, operational Vibration >550,000 hours at full load and 25C ambient conditions MTBF demonstrated Mating Connectors (SK4) AC Input Molex 09-50-8051 (USA); Molex 09-91-0500 (UK) PINS: 08-58-0111 (SK3) DC Outputs Molex 19141-0058 (SK1)Control Signals Molex 90142-0010 (USA); PINS: 90119-2110 or Amp: 87977-3; PINS: 87309-8 Connector Kit #70-841-016, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02" (0.5mm). 3. Specifications are for convection rating at factory settings at 115 Vac input, 25C unless otherwise stated. 4. Mounting holes M1 and M2 shoud be grounded for EMI purposes. 5. Mounting hole M1 is safety ground connection. 6. Warranty: 2 year 7. Weight: 0.5 lb/0.23 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com GLS20 Series Installation & Operating Instructions Installation & Safety Mechanical Outline M1 To comply with the published safety standards, the following must be observed when using this power supply: M2 GND 1. Maximum ambient temperature for the power supply must not exceed 50C. -+ 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03; including the requirements for creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. 3. The power supply's rated input voltage is automatically selected. Please refer to the specification sheet for the input voltage range. Voltage Adj. Pot SK1 SK201 1 2 3 4 5 6 3 1 SK2 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 5. The earth ground wire must be connected only to the point marked with the earth ground symbol (on the unit). 6. Hazardous voltages exist in the primary circuits. Disconnect the power supply before servicing. 7. When operating with a dc input voltage range, the unit input must be protected by a dc rated fuse in the end-use installation system. 8. The internal fuse should only be replaced with a 2.5 A, 250 V ac, type SP0001.1008 manufactured by Schurter AG or type 21602.5 manufactured by Littelfuse. Connector PIN Designation Input Connector PIN SK1 GLS24 Line Neutral PIN GLS22 GLS23 GLS24 +5 V +12 V +15 V 1 2 3 SK2 4 5 Common 6 marked following the provisions of the Low Voltage Directive, For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. GLS23 3 Output Connector 9. This equipment is considered Class I according to protection against electric shock. 10. This power supply is 2006/95/EC. GLS22 1 SK201 1 +Sense 2 -Sense NOTE: Mounting holes M1 and M2 should be grounded for EMI purposes. Mounting hole M1 is an earth ground connection. Output Ratings Model Output Voltage (V) Convection Cooling Max. Output Current (A) GLS22 +5 5.0 GLS23 +12 2.1 GLS24 +15 1.7 Max. Output Power (W) 30 CFM Forced Air Cooling Max. Output Current (A) Max. Output Power (W) 8.0 25 3.3 40 2.7 P/N: A272-178 Rev 1 01/06/10 Ref: 03361001723 GLS20 Series Installation & Operating Instructions Mechanical Dimensions Typical Ventilation Setup .15 [3.81] diameter (4X) .22 [5.6] 3.00 [76.2] 2.55 [64.8] FAN 6.69 [170.0] AIR FLOW T1 UNIT 4.55 [115.6] 5.00 [127.0] 7.28 [185.0] 1.57 [40.0] .22 [5.6] 4.33 [110.0] Top View .12 [3.0] MAX .06 [1.6] 1.08 [27.5] MAX 4.33 [110.0] FAN Bottom View AIR FLOW UNIT Side View All dimensions are in inches [mm] Side View Fan: MINEBEA 3110NL-04W-B30 Fan Input: 12 V dc NOTE: Dimensions and fan used are for reference only GLS22, GLS23, and GLS24 are commercial designations of model numbers LPS22, LPS23, and LPS24 respectively. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. GLS20 Series Specifications Electrical Specifications Input Input range 85-264 Vac; 120-300 Vdc Frequency 47-440 Hz Inrush current <15 A peak @ 115 Vac; <30 A peak @ 230 Vac, cold start @ 25C Input current 1 A max. (RMS) @ 115 Vac 70% typical at full load FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted Efficiency EMI filter Safety ground leakage current <0.5 mA @ 50/60 Hz, 264 Vac input Output Maximum power 25 W for convection; 40 W with 30 CFM forced air Adjustment range -5, +10% minimum 20 ms @ 25 W load, 115 Vac nominal line Short circuit protection on all outputs Case overload protected @ 110-145% above peak rating Hold-up time Overload protection Overvoltage protection Remote sense 5 V output; 5.7 to 6.7 Vdc. Other outputs 10% to 25% above nominal output Compensates for 0.5 V lead drop minimum;Will operate without remote sense connected. Reverse connection protected. Environmental Specifications Operating temperature 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C, -20C start up. -40C to 85C Storage temperature Electromagnetic susceptibility Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Humidity Operating; non-condensing 5% to 95% RH Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5 Hz to 500 Hz, operational >550,000 hours at full load and 25C ambient conditions MTBF demonstrated Mating Connectors Power Derating Curve AC Input Molex 09-50-8031 (USA) Not required for (-T) option 09-91-0300 (UK); PINS: 08-52-0113 DC Outputs Molex 09-50-8061 (USA) Not required for (-T) option 09-91-0600 (UK); PINS: 08-52-0113 Remote Sense Molex 22-01-2025; PINS: 08-52-0123 Connector Kit #70-841-006, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02" (0.5mm). 3. Mounting holes M1 and M2 should be grounded for EMI purposes. 4. Mounting hole M1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 Vac input, 25C unless otherwise stated. 6. Warranty: 2 year 7. Weight: 0.5lb/0.23kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com Power Derating Curve 40W 30 CFM Forced Air Cooling 30W Output Power 25W (Watts) 20W 20W Natural Convection Cooling 10W 12.5W 0W 0C 10C 20C 30C 40C 50C 60C TA - Ambient Temperature - C 70C GLS200-M Series Installation & Operating Instructions Output Ratings To comply with the published safety standards, the following must be observed when using this power supply: 1. Maximum ambient temperature for the power supply must not exceed 50C. Derate each output 2.5% per degree from 50C to 70C ambient temperature. 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, CSA22.2 No. 60950-1-03, UL60601-1, EN60601-1, IEC60601-1, and CSA22.2 No. 601.1. The safety requirements include creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. Model Output Voltage (V) GLS202-M GLS203-M GLS204-M 3. The ac-dc input connector is approved as a component of the power supply, however, it was not specifically evaluated to IEC60320. GLS205-M 4. This power supply is approved and certified for the rated voltage range of 100 V ac to 250 V ac and/or 120 V dc minimum to 300 V dc maximum. GLS208-M +5 20.0 +12_FAN 0.5 7. The disconnection from the line must be in the end system. 8. Hazardous voltages exist in the primary circuits. Disconnect power supply before servicing. 9. When operating with a dc input voltage range, the unit must be protected by a dc rated fuse in the end-use installation system. 100 30 CFM Forced Air Cooling Max. Output Current (A) 40.0 1.0 +12 10.4 0.5 1.0 +15 8.3 16.6 +12_FAN 0.5 +24 5.2 200 20.83 125 1.0 10.4 +12_FAN 0.5 1.0 +48 2.6 5.2 +12_FAN 0.5 1.0 Input Connector PIN 250 Line P1 Output Connector SK2 SK3 Designation Neutral SK1 NOTE: The power supply has a fuse on the neutral line. Earth GND PIN Designation - Common + Main output 1 +Remote sense 2 -Remote sense 3 N/C 4 N/C 5 Power fail 6 Common 7 N/C 12. This equipment is considered Class I according to protection against electric shock. 8 Common 13. This power supply is 2006/95/EC. 9 +12 V_FAN 10 +12 V_FAN return marked following the provisions of the Low Voltage Directive, Max. Output Power (W) Connector PIN Designation 10. The internal fuses (F1 & F2) should only be replaced with a F5AH, 250 V ac, type 50CF manufactured by Hollyland or type 216005.MXEP manufactured by Littelfuse. 11. The power supply has no patient applied part. Max. Output Power (W) +12_FAN 5. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 6. The earth ground wire must be connected only to the point marked with the earth ground symbol (on the unit). Convection Cooling Max. Output Current (A) 14. For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions. P/N: A272-197 Rev 0 5/11/09 Ref: 03366205860 GLS200-M Series Installation & Operating Instructions Mechanical Outline & Dimensions 5.00 [127.0] .22 [5.7] 4.55 [115.6] .22 [5.7] 5 10 1 6 SK2N SK1 2.55 [64.8] VR1 Output Voltage Adjust Pot 3.00 [76.2] SK3 SK2+ L P1 Top View 1.32 [33.6] max. Side View .098 [2.5] max. All dimensions are in inches [mm] Mounting hole diameter (4X) = 0.15 [3.81 mm] Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions. GLS202-M, GLS203-M, GLS204-M, GLS205-M, and GLS208-M are commercial designations of model numbers LPS202-M, LPS203-M, LPS204-M, LPS205-M, and LPS208-M respectively. (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. GLS200-M Series Specifications Electrical Specifications Input 90-264 Vac; 120-300 Vdc 47-63 Hz 50 A max, cold start @ 25C 86% typical at full load FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE 0878 PT3 Class B conducted 0.99 typical Input range Frequency Inrush current Efficiency EMI/RFI Power factor Safety ground leakage current 275 A @ 50/60 Hz, 264 Vac input Output Maximum power 125 W for convection; 250 W (200 W for GLS202-M) with 30 CFM forced air Adjustment range 10% min. on the main outputs 12 V @ 1 A isolated, 10% Fan output 16 ms @ 250 W load, 120 Vac input Short circuit protection on all outputs. Case overload protected @ 110-160% above peak rating 15% to 50% above nominal output Hold-up time Overload protection Overvoltage protection Logic Control Power failure Open collector logic signal goes high 100-500 msec after main output. It goes low at least 6 msec before loss of regulation Remote sense Compensates for 0.5 V lead drop minimum, will operate without remote sense connected. Reverse connection protected Environmental Specifications Operating temperature 0 to 50C ambient. Derate each output at 2.5% per degree from 50 to 70C. -20C start up -40C to 85C Storage temperature Electromagnetic susceptibility Humidity Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Operating; non-condensing 10% to 95% RH IEC68-2-6 to the levels of IEC721-3-2 Vibration >550,000 hours at full load and 25C ambient conditions MTBF demonstrated Mating Connectors (SK1) AC Input Molex P/N: 09-50-8031 (connector), PINS: 08-52-0113 AC Ground Molex: 01-90020001 (SK2) DC Outputs (SK3) Control Signals Molex 19141-0058/0063/0083; Spade lug based on Cable Ampacity/AWG Molex 90142-0010 (USA), PINS: 90119-2110 or Amp: 87977-3, PINS: 87309-8 Connector Kit #70-841-020, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02". 3. Specifications are for convection rating at factory settings at 115 Vac input 25C unless otherwise stated. 4. Mounting holes MH1 and MH2 should be grounded for EMI purposes. 5. 6. 7. 8. Mounting hole MH1 is safety ground connection. This power supply requires mounting on metal standoffs 0.20" (5 m) in height. Warranty: 2 year Weight: 0.75 lb/0.34 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com GLS253-C, GLS255-C Installation & Operating Instructions Mechanical Outline To comply with the published safety standards, the following must be observed when using this power supply: A Bus B Bar 1. Maximum ambient temperature for GLS255-C must not exceed 50C. Maximum ambient temperature for GLS253-C must not exceed 50C at 250 W, 21 A or 70C at 125 W, 10.5 A. 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03; including the requirements for creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. Output Adj. 3 SK1 2 1 3. The power supply's rated input voltage is automatically selected. Please refer to the specification sheet for the input voltage range. 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 5. This unit contains a secondary output exceeding 240 VA. When installing the unit into the end system, make sure the secondary output and the appropriate wire cannot be touched. 6. The earth ground wire must be connected only to the point marked with the earth ground symbol (on the unit). The unit must be protected by a fuse in the end system. SK1 1 2 3 Output Connector PIN GLS253-C GLS255-C A B 1 2 3 +6 V to +12 V +24 V to +48 V SK3 SK4 SK5 SK7 11. This equipment is considered Class I according to protection against electric shock. 12. This power supply is 2006/95/EC. Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions 4 5 6 7 8 1 GLS253-C GLS255-C Neutral Line Earth GND Common +Sense -Sense Inhibit (normally open) Inhibit (normally closed) Common C. Share P OK Dc OK Fan (+) 2 Fan (-) 1 2 1 +5 V (aux) Common Fan (+) 2 Fan (-) Output Ratings marked following the provisions of the Low Voltage Directive, 13. For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. SK3 PIN 8. Hazardous voltages exist in the primary circuits. Disconnect the power supply before servicing. NOTE: Components, such as capacitors, may be positioned in front of the internal fuse. 8 Input Connector Bus Bar 10. The internal fuse should only be replaced with a F6.3AH, 250 V ac, type 21606.3 manufactured by Littelfuse, type 50CF063H manufactured by Triad, or type S501 manufactured by Cooper. 1 SK4 SK5 Connector PIN Designation 7. The disconnection from the line must be in the end system. 9. When operating with a dc input voltage range, the unit input must be protected by a dc rated fuse in the end-use installation system. SK7 Model GLS253-C GLS255-C Output Voltage (V) +6 to +12 +24 to +48 30 CFM Forced Air Cooling (unit not convection rated) Max. Output Current (A) Max. Output Power (W) 21.0 10.4 250 with cover P/N: A272-193 Rev 0 5/5/09 Ref: 03361002223 GLS253-C, GLS255-C Installation & Operating Instructions Mechanical Dimensions 1.18 [30.0] Typical Ventilation Setup 9.00 [228.6] 6.63 [168.6] .59 [15.0] 2.50 [63.5] BASEPLATE (0.039 in/1mm THK. SHEET ALUMINIUM) 3.42 [87.0] SK1 10.00 [254.0] POWER SUPPLY UNIT 5.00 [127.0] AIR FLOW Bottom View F A N .50 [12.7] 2.50 [63.5] 14.00 [355.6] 5.00 [127.0] Fan Used: Minebea 2410ML-04W-B60, 12 V dc, 0.40 A Dc Input for Fan Testing: 12 V dc NOTE: Dimensions and fan used are for reference only Top View 216.40 [8.51] 2.50 [63.5] 1.18 [30.0] .24 [6.1] 9.00 [228.6] Side View All dimension are in inches [mm] Screw Size: #6-32 Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions. GLS253-C and GLS255-C are commercial designations of model numbers LPS253 and LPS255 respectively. (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. GLS250 Series Specifications Electrical Specifications Input 85-264 Vac; 120-300 Vdc 47-440 Hz 20 A max, cold start @ 25C 75% typical at full load FCC Class B conducted and radiated; CISPR 22 Class B conducted and radiated; EN55022 Class B conducted and radiated; VDE 0878 PT3 Class B conducted and radiated Input range Frequency Inrush current Efficiency EMI filter Safety ground leakage current <0.5 mA @ 50/60 Hz, 264 Vac input Output With cover: 250 W with 30 CFM forced air, (-C) (-CF) (-CEF) Maximum power 2:1 wide ratio Adjustment range 5 V @ 100 mA regulated, 12 V @ 500 mA Supervisory output 20 ms @ 250 W load, 115 Vac nominal line Short circuit protection on all outputs. Case overload protected @ 10-145% above peak rating 5 V output: 5.7 to 6.7 Vdc; Other models 10% to 25% above nominal output Hold-up time Overload protection Overvoltage protection 1st output: 0.63 A - GLS253-C; 0.32 A -GLS255-C Minimum load Logic Control Power failure TTL logic signal goes high 50-150 msec after 5 V output. It goes low at least 4 msec before loss of regulation Remote on/off Requires an external contact (N.O. or N.C.) to inhibit outputs TTL logic goes high 50-150 msec after the output. It goes low when there is loss of regulation DC-OK Compensates for 0.5 V lead drop minimum, will operate without remote sense connected. Reverse connection protected Remote sense Environmental Specifications Operating temperature 0 to 50C ambient. Derate each output at 2.5% per degree from 50 to 70C Storage temperature Temperature coefficient Electromagnetic susceptibility Humidity -40C to 85C 0.4% per C Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Operating; non-condensing 5% to 95% Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.7 G peak 5Hz to 500Hz, operational Vibration >550,000 hours at full load and 25C ambient conditions MTBF demonstrated Mating Connectors SK3 SK4 SK5 SK7 Molex 22-01-1084 PINS: 08-70-0057 Molex 22-01-3027 PINS: 08-50-0114 Molex 22-01-3027 PINS: 08-50-0114 Molex 22-01-3027 PINS: 08-50-0114 Connector Kit #70-841-005, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02". 3. Specifications are at factory settings unless otherwise stated. 4. To enable normally closed remote inhibit, cut jumper J1. 5. Mounting maximum insertion depth is .12". 6. Warranty: 2 year 7. Weight: 2.6 lbs/1.19 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com GLS352-C, GLS353-C Installation & Operating Instructions Installation & Safety Mechanical Outline To comply with the published safety standards, the following must be observed when using this power supply: TB1 +V out Common 1. Maximum ambient temperature for the power supply must not exceed 50C. 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03; including the requirements for creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. 3. The power supply's rated input voltage is automatically selected. Please refer to the specification sheet for the input voltage range. 3 6. Hazardous voltages exist in the primary circuits. Disconnect the power supply before servicing. 7. The internal fuse should only be replaced with a F10AH, 250 V ac, type SP0001.1014 manufactured by Schurter AG or type 216010 manufactured by Littelfuse. 8. This power supply is tive, 2006/95/EC. 1 Input Connector Model Output Voltage (V) GLS352-C 5 (+3 to +6) 70.0 GLS353-C 12 (+6 to +12) 29.2 Max. Output Current (A) Max. Output Power (W) 350 with cover PIN 1 SK3 10 GLS352-C 1 SK1 Output Connector TB1 SK3 Output Ratings 30 CFM Forced Air Cooling (unit not convection rated) J1 Connector PIN Designation marked following the provisions of the Low Voltage Direc- For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. SK4 SK5 SK6 SK1 2 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 5. This unit contains a secondary output exceeding 240 VA. When installing the unit into the end system, make sure the secondary output and the appropriate wire cannot be touched. Output Voltage Adjust Trimmer SK4 SK5 SK6 GLS353-C Neutral 2 Line 3 Earth GND PIN + GLS352-C GLS353-C V1 positive - V1 common 1 No connection 2 No connection 3 +Sense 4 -Sense 5 P OK 6 C. Share 7 Dc OK 8 Inhibit (normally open) 9 Inhibit (normally closed) 10 Common 1 +5 V (aux) 2 Common 1 +Fan 1 (+12 V) 2 Common 1 +Fan 2 (+12 V) 2 Common P/N: A272-171 Rev 2 12/29/09 Ref: 03366200232 GLS352-C, GLS353-C Installation & Operating Instructions Mechanical Dimensions 1.18 [30.0] Typical Ventilation Setup 6.63 [168.6] 2.50 [63.5] 9.00 [228.6] .59 [15.0] BASEPLATE (0.039 in/1mm THK. SHEET ALUMINIUM) 3.42 [87.0] SK1 10.00 [254.0] POWER SUPPLY UNIT Bottom View AIR FLOW F A N 5.00 [127.0] .50 [12.7] 2.50 [63.5] 14.00 [355.6] 5.00 [127.0] Fan Used: Minebea 2410ML-04W-B60, 12 V dc, 0.40 A or Cheng Home CHA6012EB, 12 V dc, 0.28 A Dc Input for Fan Testing: 12 V dc NOTE: Dimensions and fan used are for reference only Top View 216.40 [8.51] 2.50 [63.5] 1.18 [30.0] .24 [6.1] 9.00 [228.6] Side View All dimension are in inches [mm] Screw Size: #6-32 GLS352-C and GLS353-C are commercial designations of model numbers LPS352-C and LPS353-C respectively. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. GLS350 Series Specifications Electrical Specifications Input 85-264 Vac; 120-300 Vdc 47-440 Hz 38 A max, cold start @ 25C 75% typical at full load FCC Class B conducted and radiated; CISPR 22 Class B conducted and radiated; EN55022 Class B conducted and radiated; VDE 0878 PT3 Class B conducted and radiated 0.99 typical Input range Frequency Inrush current Efficiency EMI filter Power factor Safety ground leakage current <0.5 mA @ 50/60 Hz, 264 Vac input Output With cover: 350 W with 30 CFM forced air, (-C) (-CF) (-CEF) Maximum power 2:1 wide ratio Adjustment range 5 V @ 500 mA regulated, 12 @ 150 mA x2 Supervisory output 20 ms @ 350W load, 115 Vac nominal line at factory voltage settings Short circuit protection on all outputs. Case overload protected @ 110-145% above peak rating 5 V output: 5.7 to 6.7 Vdc; Other models 10% to 25% above nominal output Hold-up time Overload protection Overvoltage protection Logic Control Power failure TTL logic signal goes high 50-150 msec after the output is in regulation. It goes low at least 4 msec before loss of regulation Remote on/off Requires an external contact (N.O. or N.C.) to inhibit outputs TTL logic goes high 50-150 msec after the output is in regulation. It goes low when there is loss of regulation DC-OK Compensates for 0.5 V lead drop minimum, will operate without remote sense connected. Reverse connection protected Remote sense Environmental Specifications Operating temperature 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C Storage temperature Temperature coefficient Electromagnetic susceptibility Humidity -40C to 85C 0.04% per C Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Operating; non-condensing 5% to 95% Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.7 G peak 5Hz to 500Hz, operational Vibration >550,000 hours at full load and 25C ambient conditions MTBF demonstrated Mating Connectors SK3 SK4 SK5 SK6 Molex 22-01-1104 PINS: 08-70-0057 Molex 22-01-3027 PINS: 08-50-0114 Molex 22-01-3027 PINS: 08-50-0114 Molex 22-01-3027 PINS: 08-50-0114 Connector Kit #70-841-011, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02". 3. Specifications are at factory settings unless otherwise stated. 4. To enable normally closed Remote inhibit, cut jumper J1. 5. Mounting (6-32) maximum insertion depth is .12". 6. Warranty: 2 years 7. Weight: 3.6 lbs/1.64 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com GLS354-C, GLS355-C, GLS355-CEF Installation & Operating Instructions Installation & Safety Mechanical Outline To comply with the published safety standards, the following must be observed when using this power supply: TB1 +V out Common 1. Maximum ambient temperature for the power supply must not exceed 50C. 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03; including the requirements for creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. Output Voltage Adjust Trimmer 3 1 3. The power supply's rated input voltage is automatically selected. Please refer to the specification sheet for the input voltage range. 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 5. This unit contains a secondary output exceeding 240 VA. When installing the unit into the end system, make sure the secondary output and the appropriate wire cannot be touched. 6. Hazardous voltages exist in the primary circuits. Disconnect the power supply before servicing. 7. The internal fuse should only be replaced with a F10AH, 250 V ac, type SP0001.1014 manufactured by Schurter AG or type 216010 manufactured by Littelfuse. 8. This power supply is Directive, 2006/95/EC. Output Ratings Input Connector SK1 Output Connector TB1 SK3 SK4 30 CFM Forced Air Cooling (unit not convection rated) Model Output Voltage (V) GLS354-C 15 (+12 to +24) 23.4 GLS355-C (-CEF) 24 (+24 to +48) 14.6 Max. Output Current (A) Max. Output Power (W) 350 with cover J1 1 SK3 10 Connector PIN Designation marked following the provisions of the Low Voltage For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. SK4 SK5 SK6 SK1 2 SK5 SK6 PIN Designation 1 Neutral 2 Line 3 Earth GND PIN Designation + V1 positive - V1 common 1 No connection 2 No connection 3 +Sense 4 -Sense 5 P OK 6 C. Share 7 Dc OK 8 Inhibit (normally open) 9 Inhibit (normally closed) 10 Common 1 +5 V (aux) 2 Common 1 +Fan 1 (+12 V) 2 Common 1 +Fan 2 (+12 V) 2 Common P/N: A272-172 Rev 2 01/06/10 Ref: LPS354&355\OP.K GLS354-C, GLS355-C, GLS355-CEF Installation & Operating Instructions Mechanical Dimensions 2.42 [61.4] Typical Ventilation Setup 6.65 [168.6] 2.50 [63.5] SK1 1.71 [43.5] 0.65 [16.5] 10.00 [254.0] 1.12 [28.5] .59 [15.0] BASEPLATE (0.039 in/1mm THK. SHEET ALUMINIUM) 1.71 [43.5] 2.48 [63.0] 9.00 [228.6] Bottom View POWER SUPPLY UNIT AIR FLOW F A N 5.00 [127.0] .50 [12.7] 10.24 [260.0] 2.50 [63.5] 5.00 [127.0] 14.00 [355.6] Fan Used: Minebea 2410ML-04W-B60, 12 V dc, 0.40 A or Cheng Home CHA6012EB, 12 V dc, 0.28 A Dc Input for Fan Testing: 12 V dc 1.40 [35.5] 2.00 [50.9] Top View NOTE: Dimensions and fan used are for reference only NOTE: Not applicable for -CEF models 3.29 [83.5] 1.18 [30.0] 0.20 [5.0] 1.48 [37.5] 8.52 [216.4] Side View All dimensions are in inches [mm] Screw Size: a = #6-32 (U.S.); b = M3 (international) GLS354-C, GLS355-C and GLS355-CEF are commercial designations of model numbers LPS354-C, LPS355-C and LPS355-CEF respectively. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. GLS350 Series Specifications Electrical Specifications Input 85-264 Vac; 120-300 Vdc 47-440 Hz 38 A max, cold start @ 25C 75% typical at full load FCC Class B conducted and radiated; CISPR 22 Class B conducted and radiated; EN55022 Class B conducted and radiated; VDE 0878 PT3 Class B conducted and radiated 0.99 typical Input range Frequency Inrush current Efficiency EMI filter Power factor Safety ground leakage current <0.5 mA @ 50/60 Hz, 264 Vac input Output With cover: 350 W with 30 CFM forced air, (-C) (-CF) (-CEF) Maximum power 2:1 wide ratio Adjustment range 5 V @ 500 mA regulated, 12 @ 150 mA x2 Supervisory output 20 ms @ 350W load, 115 Vac nominal line at factory voltage settings Short circuit protection on all outputs. Case overload protected @ 110-145% above peak rating 5 V output: 5.7 to 6.7 Vdc; Other models 10% to 25% above nominal output Hold-up time Overload protection Overvoltage protection Logic Control Power failure TTL logic signal goes high 50-150 msec after the output is in regulation. It goes low at least 4 msec before loss of regulation Remote on/off Requires an external contact (N.O. or N.C.) to inhibit outputs TTL logic goes high 50-150 msec after the output is in regulation. It goes low when there is loss of regulation DC-OK Compensates for 0.5 V lead drop minimum, will operate without remote sense connected. Reverse connection protected Remote sense Environmental Specifications Operating temperature 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C Storage temperature Temperature coefficient Electromagnetic susceptibility Humidity -40C to 85C 0.04% per C Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Operating; non-condensing 5% to 95% Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.7 G peak 5Hz to 500Hz, operational Vibration >550,000 hours at full load and 25C ambient conditions MTBF demonstrated Mating Connectors SK3 SK4 SK5 SK6 Molex 22-01-1104 PINS: 08-70-0057 Molex 22-01-3027 PINS: 08-50-0114 Molex 22-01-3027 PINS: 08-50-0114 Molex 22-01-3027 PINS: 08-50-0114 Connector Kit #70-841-011, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02". 3. Specifications are at factory settings unless otherwise stated. 4. To enable normally closed Remote inhibit, cut jumper J1. 5. Mounting (6-32) maximum insertion depth is .12". 6. Warranty: 2 years 7. Weight: 3.6 lbs/1.64 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com GLS40 Series, GLS40-M Series Installation & Operating Instructions Installation & Safety Mechanical Outline M2 M1 To comply with the published safety standards, the following must be observed when using this power supply: 1. Maximum ambient temperature for the power supply must not exceed 50C. The power supply has been evaluated for use in 70C at half load. 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03 for GLS42, GLS43, GLS44, and GLS45; UL60601-1, EN60601-1, IEC60601-1, and CSA22.2 No. 60601-1-M90 for GLS42-M, GLS43-M, GLS44-M, and GLS45-M. The safety requirements include creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. Voltage Adj. Pot 1 2 3 4 SK1 SK2 5 3 6 1 3. The power supply's rated input voltage is automatically selected. Please refer to the specification sheet for the input voltage range. 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 5. The earth ground wire must be connected only to the point marked with the earth ground symbol (on the unit). 6. Hazardous voltages exist in the primary circuits. Disconnect the power supply before servicing. Connector PIN Designation Input Connector PIN SK1 9. GLS42-M, GLS43-M, GLS44-M, and GLS45-M have no patient applied part. 10. This equipment is considered Class I according to protection against electric shock. 11. This power supply is 2006/95/EC. marked following the provisions of the Low Voltage Directive, GLS43 (-M) PIN GLS44 (-M) GLS45 (-M) Line 3 Output Connector Neutral GLS42 (-M) GLS43 (-M) GLS44 (-M) GLS45 (-M) +5 V +12 V +15 V +24 V 1 7. When operating with a dc input voltage range, the unit input must be protected by a dc rated fuse in the end-use installation system. 8. The internal fuse should only be replaced with a 2.5 A, 250 V ac, type SP0001.1008 manufactured by Schurter AG or type 21602.5 manufactured by Littelfuse. GLS42 (-M) 1 2 3 SK2 4 5 Common 6 SK201 1 +Sense 2 -Sense Note: Mounting holes M1 and M2 should be grounded for EMI purposes. Mounting hole M1 is an earth ground connection. Output Ratings For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. Model Output Voltage (V) GLS42 (-M) +5 Convection Cooling Max. Output Current (A) Max. Output Power (W) 8.0 GLS43 (-M) +12 3.3 GLS44 (-M) +15 2.6 GLS45 (-M) +24 1.7 30 CFM Forced Air Cooling Max. Output Current (A) Max. Output Power (W) 11.0 40 4.5 3.6 55 2.3 P/N: A272-180 Rev 1 01/06/10 Ref: 03361001145 GLS40 Series, GLS40-M Series Installation & Operating Instructions Mechanical Dimensions Typical Ventilation Setup .15 [3.81] diameter (4X) .22 [5.6] 3.00 [76.2] 2.55 [64.8] FAN 6.69 [170.0] AIR FLOW T1 UNIT 4.55 [115.6] 5.00 [127.0] 7.28 [185.0] 1.57 [40.0] .22 [5.6] 4.33 [110.0] Top View .12 [3.0] MAX .06 [1.6] 1.08 [27.5] MAX 4.33 [110.0] FAN Bottom View AIR FLOW UNIT Side View All dimensions are in inches [mm] Side View Fan: MINEBEA 3110NL-04W-B30 Fan Input: 12 V dc NOTE: Dimensions and fan used are for reference only GLS42, GLS43, GLS44, GLS45, GLS42-M, GLS43-M, GLS44-M, and GLS45-M are commercial designations of model numbers LPS42, LPS43, LPS44, LPS45, LPS42-M, LPS43-M, LPS44-M, and LPS45-M respectively. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. GLS40, GLS40-M Series Specifications Electrical Specifications Input Input range 85-264 Vac; 120-300 Vdc Frequency 47-440 Hz Inrush current <18 A peak @ 115 Vac; <36 A peak @ 230 Vac, cold start @ 25C Input current 1 A max. (RMS) @ 115 Vac 70% typical at full load FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE 0878 PT3 Class B conducted <0.5 mA @ 50/60 Hz, 264 Vac input; GLS40-M: <75A @ 50/60 Hz, 264 Vac input Efficiency EMI filter Safety ground leakage current Output Maximum power 40 W convection; 55 W with 30 CFM forced air Adjustment range -5, +10% minimum 20 ms @ 40 W load, 115 Vac nominal line Short circuit protection on all outputs Case overload protected @ 110-145% above peak rating 5 V output; 5.7 to 6.7 Vdc. Other outputs 10 to 25% above nominal output Hold-up time Overload protection Overvoltage protection Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Remote sense Environmental Specifications Operating temperature 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C. -20C start up. Storage temperature -40C to 85C Temperature coefficient Electromagnetic susceptibility 0.4% per C Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Humidity Operating; non-condensing 5% to 95% RH Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75 G peak 5 Hz to 500 Hz, operational Power Derating Curve Mating Connectors AC Input DC Outputs Remote Sense Molex 09-50-8031 (USA) Not required for (-T) option; 09-91-0300 (UK) PINS: 08-52-0113 Molex 09-50-8061 (USA) Not required for (-T) option; 09-91-0600 (UK) PINS: 08-52-0113 Molex 22-01-2025; PINS 08-52-0123 Power Derating Curve 55W 30 CFM Forced Air Cooling 40W Connector Kit #70-841-006, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02" (0.5mm). 3. Mounting holes M1 and M2 should be grounded for EMI purposes. Output Power (Watts) 30W 27.5W Natural Convection Cooling 20W 20W 10W 4. Mounting hole M1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 Vac input, 25C unless otherwise stated. 6. Warranty: 2 year 0W 0C 10C 20C 30C 40C 50C 60C TA - Ambient Temperature - C 7. Weight: 0.5 lb/0.23 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com 70C GLS503-CF, GLS503-M-CF Installation & Operating Instructions Installation & Safety Mechanical Outline To comply with the published safety standards, the following must be observed when using this power supply: 1. 2. Maximum ambient temperature for the power supply must not exceed 50C. Derate each output 2.5% per degree from 50C to 70C ambient temperature. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03 for the GLS503-CF; UL60601-1, EN60601-1, IEC60601-1, and CSA22.2 No. 60601-1 for the GLS503-M-CF. The safety requirements include creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. 3. The ac-dc input connector is approved as a component of the power supply, however, it was not specifically evaluated to IEC60320. 4. This power supply is approved and certified for the rated voltage range of 100 V ac to 250 V ac and/or 120 V dc (minimum) to 300 V dc (maximum). 5. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 6. This power supply contains a +12 V output exceeding 240 VA. When installing the unit into the end system, make sure the outputs and the appropriate wire cannot not be touched. 7. The disconnection from the line must be in the end system. 8. Hazardous voltages exist in the primary circuits. Disconnect power supply before servicing. 9. SK4 SK5 CN1 SK6 1 2 3 Input Terminal PIN Designation CN1 1 2 3 Line Neutral Earth GND Output Connector PIN 6 SK7 OR-ing terminal SK5 +12 V main SK6 Common/Return SK7 (Signal Output) 11. GLS503-M-CF has no patient applied part. 13. This power supply is 2006/95/EC. 1 Designation SK4 10. The earthing conductor in the end system should not be less than 8 awg (10 mm2) in a cross-sectional area. 12. The equipment is considered Class I according to protection against electric shock. 10 Connector PIN Designation The internal fuses (F1, F2) should only be replaced by a F10AH A, 250 V ac, type 216010 MXEP manufactured by Littelfuse or type 5HFP manufactured by Belfuse. NOTE: The power supply has a fuse on the on the neutral line. 5 1 V1 SWP (Single Wire Parallel) 2 3 4 5 -Remote sense +Remote sense +5 V standby Standby return 6 7 8 9 10 +12 V (fan out) Common Remote inhibit Dc power good Power fail Note: For information on the I2C Header (CN403) and Fan Header (SK8), please contact Technical Support. marked following the provisions of the Low Voltage Directive, For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. Output Ratings Convection Cooling 30 CFM Forced Air Cooling Output Voltage (V) Max. Output Current (A) Max. Output Power (W) Max. Output Current (A) Max. Output Power (W) +12 +5 standby +12 (fan out) 16.67 1.00 0.50 200 41.67 2.00 0.50 500 with cover fan P/N: A272-173 Rev 2 01/06/10 Ref: 03366205360 GLS503-CF, GLS503-M-CF Installation & Operating Instructions Mechanical Dimensions 1.24 [31.45] 1.15 [29.1] .75 [19.1] b b a a .25 [6.4] 1.50 [38.1] 5.85 [148.7] 6.25 [158.7] Side View b a a b b a a b 4.00 [101.6] 2.50 [63.5] 4.71 [119.6] 5.50 [139.7] 7.00 [177.8] Bottom View All dimensions are in inches [mm] Screw Size: a = M3 (International); b = #6-32 (U.S.) GLS503-CF and GLS503-M-CF are commercial designations of model numbers NTS503 and NTS503-M respectively. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. GLS500, GLS500-M Series Specifications Electrical Specifications Input 85-264 Vac (wide range) 47-63 Hz 50 A max, cold start @ 25C 85% typical at full load, nominal line FCC Class B conducted and radiated; CISPR 22 Class B conducted and radiated; EN55022 Class B conducted and radiated; VDE 0878 PT3 Class B conducted and radiated Input range Frequency Inrush current Efficiency EMI filter Safety ground leakage current <0.5 mA @ 50/60 Hz, 264 Vac input (<0.3 mA @ 50/60 Hz, 264 Vac input for GLS500-M) Output 200 W convection; 500 W with 30 CFM forced air Maximum power 5% Adjustment range 5 V @ 1 A convection, 2 A forced air, regulated, 5% Standby output 12 V @ 1 A, -5%, +7%, 0.5 A for -CF version Fan output 20 ms @ 500 W load, 115 Vac nominal line at factory voltage setting Short circuit protection on all outputs Case overload protected @ 115-130% above peak rating 20-35% above nominal output Hold-up time Overload protection Overvoltage protection Logic Control Power failure TTL logic signal goes high 100-500 msec after main output. It goes low at least 4 msec before loss of regulation. Remote on/off Requires an external contact closure to inhibit outputs TTL logic goes high after the output is in regulation. It goes low when there is loss of regulation. DC OK Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Remote sense Environmental Specifications Operating temperature 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C -40C to 85C Storage temperature Electromagnetic susceptibility Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity Operating; non-condensing 10% to 90% RH Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 2 G peak 8Hz to 500Hz, operational Mating Connectors SK4,5,6 Molex 19141-0058 SK7 Control Signal Molex 90142-0010; PINS: 90119-2110 or Amp 87977-3; PINS: 87309-8 SK8 CN403 JST PHR-2; PINS: SPH-002T-PO.5S JST PHDR-10VS; PINS: JST 5PHD-002T-PO.5-L/P or Landwin 2050 S1000; PINS: 2053T011P Connector Kit #70-841-024, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02" (0.5mm) 3. Specifications are at factory settings unless otherwise stated. 4. Mounting screw maximum insertion depth is .12". 5. Warranty: 2 years 6. Weight: 3.016 lbs/1.18 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com GLS505-CF, GLS505-M-CF Installation & Operating Instructions Installation & Safety Mechanical Outline To comply with the published safety standards, the following must be observed when using this power supply: 1. 2. Maximum ambient temperature for the power supply must not exceed 50C. Derate each output 2.5% per degree from 50C to 70C ambient temperature. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03 for the GLS505-CF; UL60601-1, EN60601-1, IEC60601-1, and CSA22.2 No. 60601-1 for the GLS505-M-CF. The safety requirements include creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. 3. The ac-dc input connector is approved as a component of the power supply, however, it was not specifically evaluated to IEC60320. 4. This power supply is approved and certified for the rated voltage range of 100 V ac to 250 V ac and/or 120 V dc (minimum) to 300 V dc (maximum). 5. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 6. This power supply contains a +24 V output exceeding 240 VA. When installing the unit into the end system, make sure the outputs and the appropriate wire cannot not be touched. 7. The disconnection from the line must be in the end system. 8. Hazardous voltages exist in the primary circuits. Disconnect power supply before servicing. 9. SK4 SK5 CN1 SK6 1 2 3 10. The earthing conductor in the end system should not be less than 8 awg (10 mm2) in a cross-sectional area. 11. GLS505-M-CF has no patient applied part. 12. The equipment is considered Class I according to protection against electric shock. 13. This power supply is 2006/95/EC. Input Terminal PIN Designation CN1 1 2 3 Line Neutral Earth GND Output Connector PIN 1 6 SK7 Designation SK4 OR-ing terminal SK5 +24 V main SK6 Common/Return SK7 (Signal Output) 1 V1 SWP (Single Wire Parallel) 2 3 4 5 -Remote sense +Remote sense +5 V standby Standby return 6 +12 V (fan out) 7 Common 8 Remote inhibit 9 Dc power good 10 Power fail Note: For information on the I2C Header (CN403) and Fan Header (SK8), please contact Technical Support. marked following the provisions of the Low Voltage Directive, For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. 10 Connector PIN Designation The internal fuses (F1, F2) should only be replaced by a F10AH A, 250 V ac, type 216010 MXEP manufactured by Littelfuse or type 5HFP manufactured by Belfuse. NOTE: The power supply has a fuse on the neutral line. 5 Output Ratings Convection Cooling 30 CFM Forced Air Cooling Output Voltage (V) Max. Output Current (A) Max. Output Power (W) Max. Output Current (A) Max. Output Power (W) +24 +5 standby +12 (fan out) 8.34 1.00 0.50 200 20.84 2.00 0.50 500 with cover fan P/N: A272-174 Rev 2 12/29/09 Ref: 03366205620 GLS505-CF, GLS505-M-CF Installation & Operating Instructions Mechanical Dimensions 1.24 [31.45] 1.15 [29.1] .75 [19.1] b b a a .25 [6.4] 1.50 [38.1] 5.85 [148.7] 6.25 [158.7] Side View b a a b b a a b 4.00 [101.6] 2.50 [63.5] 4.71 [119.6] 5.50 [139.7] 7.00 [177.8] Bottom View All dimensions are in inches [mm] Screw Size: a = M3 (International); b = #6-32 (U.S.) GLS505-CF and GLS505-M-CF are commercial designations of model numbers NTS505 and NTS505-M respectively. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. GLS500, GLS500-M Series Specifications Electrical Specifications Input 85-264 Vac (wide range) 47-63 Hz 50 A max, cold start @ 25C 85% typical at full load, nominal line FCC Class B conducted and radiated; CISPR 22 Class B conducted and radiated; EN55022 Class B conducted and radiated; VDE 0878 PT3 Class B conducted and radiated Input range Frequency Inrush current Efficiency EMI filter Safety ground leakage current <0.5 mA @ 50/60 Hz, 264 Vac input (<0.3 mA @ 50/60 Hz, 264 Vac input for GLS500-M) Output 200 W convection; 500 W with 30 CFM forced air Maximum power 5% Adjustment range 5 V @ 1 A convection, 2 A forced air, regulated, 5% Standby output 12 V @ 1 A, -5%, +7%, 0.5 A for -CF version Fan output 20 ms @ 500 W load, 115 Vac nominal line at factory voltage setting Short circuit protection on all outputs Case overload protected @ 115-130% above peak rating 20-35% above nominal output Hold-up time Overload protection Overvoltage protection Logic Control Power failure TTL logic signal goes high 100-500 msec after main output. It goes low at least 4 msec before loss of regulation. Remote on/off Requires an external contact closure to inhibit outputs TTL logic goes high after the output is in regulation. It goes low when there is loss of regulation. DC OK Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Remote sense Environmental Specifications Operating temperature 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C -40C to 85C Storage temperature Electromagnetic susceptibility Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity Operating; non-condensing 10% to 90% RH Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 2 G peak 8Hz to 500Hz, operational Mating Connectors SK4,5,6 Molex 19141-0058 SK7 Control Signal Molex 90142-0010; PINS: 90119-2110 or Amp 87977-3; PINS: 87309-8 SK8 CN403 JST PHR-2; PINS: SPH-002T-PO.5S JST PHDR-10VS; PINS: JST 5PHD-002T-PO.5-L/P or Landwin 2050 S1000; PINS: 2053T011P Connector Kit #70-841-024, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02" (0.5mm) 3. Specifications are at factory settings unless otherwise stated. 4. Mounting screw maximum insertion depth is .12". 5. Warranty: 2 years 6. Weight: 3.016 lbs/1.18 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com GLS508-CF, GLS508-M-CF Installation & Operating Instructions Installation & Safety Mechanical Outline To comply with the published safety standards, the following must be observed when using this power supply: 1. 2. Maximum ambient temperature for the power supply must not exceed 50C. Derate each output 2.5% per degree from 50C to 70C ambient temperature. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03 for the GLS508-CF; UL60601-1, EN60601-1, IEC60601-1, and CSA22.2 No. 60601-1 for the GLS508-M-CF. The safety requirements include creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. 3. The ac-dc input connector is approved as a component of the power supply, however, it was not specifically evaluated to IEC60320. 4. This power supply is approved and certified for the rated voltage range of 100 V ac to 250 V ac and/or 120 V dc (minimum) to 300 V dc (maximum). 5. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 6. This power supply contains a +48 V output exceeding 240 VA. When installing the unit into the end system, make sure the outputs and the appropriate wire cannot not be touched. 7. The disconnection from the line must be in the end system. 8. Hazardous voltages exist in the primary circuits. Disconnect power supply before servicing. 9. SK4 SK5 CN1 SK6 1 2 3 10. The earthing conductor in the end system should not be less than 8 awg (10 mm2) in a cross-sectional area. 11. GLS508-M-CF has no patient applied part. 12. The equipment is considered Class I according to protection against electric shock. 13. This power supply is 2006/95/EC. Input Terminal PIN Designation CN1 1 2 3 Line Neutral Earth GND Output Connector PIN 1 6 SK7 Designation SK4 SK5 SK6 OR-ing terminal +48 V main Common/Return SK7 (Signal Output) 1 V1 SWP (Single Wire Parallel) 2 3 4 5 -Remote sense +Remote sense +5 V standby Standby return 6 +12 V (fan out) 7 Common 8 Remote inhibit 9 Dc power good 10 Power fail Note: For information on the I2C Header (CN403) and Fan Header (SK8), please contact Technical Support. marked following the provisions of the Low Voltage Directive, For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. 10 Connector PIN Designation The internal fuses (F1, F2) should only be replaced by a F10AH A, 250 V ac, type 216010 MXEP manufactured by Littelfuse or type 5HFP manufactured by Belfuse. NOTE: The power supply has a fuse on the neutral line. 5 Output Ratings Convection Cooling 30 CFM Forced Air Cooling Output Voltage (V) Max. Output Current (A) Max. Output Power (W) Max. Output Current (A) Max. Output Power (W) +48 +5 standby +12 (fan out) 4.167 1.00 0.50 200 10.42 2.00 0.50 500 with cover fan P/N: A272-175 Rev 2 01/06/10 Ref: 03366205480 GLS508-CF, GLS508-M-CF Installation & Operating Instructions Mechanical Dimensions 1.24 [31.45] 1.15 [29.1] .75 [19.1] b b a a .25 [6.4] 1.50 [38.1] 5.85 [148.7] 6.25 [158.7] Side View b a a b b a a b 4.00 [101.6] 2.50 [63.5] 4.71 [119.6] 5.50 [139.7] 7.00 [177.8] Bottom View All dimensions are in inches [mm] Screw Size: a = M3 (International); b = #6-32 (U.S.) GLS508-CF and GLS508-M-CF are commercial designations of model numbers NTS508 and NTS508-M respectively. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. GLS500, GLS500-M Series Specifications Electrical Specifications Input 85-264 Vac (wide range) 47-63 Hz 50 A max, cold start @ 25C 85% typical at full load, nominal line FCC Class B conducted and radiated; CISPR 22 Class B conducted and radiated; EN55022 Class B conducted and radiated; VDE 0878 PT3 Class B conducted and radiated Input range Frequency Inrush current Efficiency EMI filter Safety ground leakage current <0.5 mA @ 50/60 Hz, 264 Vac input (<0.3 mA @ 50/60 Hz, 264 Vac input for GLS500-M) Output 200 W convection; 500 W with 30 CFM forced air Maximum power 5% Adjustment range 5 V @ 1 A convection, 2 A forced air, regulated, 5% Standby output 12 V @ 1 A, -5%, +7%, 0.5 A for -CF version Fan output 20 ms @ 500 W load, 115 Vac nominal line at factory voltage setting Short circuit protection on all outputs Case overload protected @ 115-130% above peak rating 20-35% above nominal output Hold-up time Overload protection Overvoltage protection Logic Control Power failure TTL logic signal goes high 100-500 msec after main output. It goes low at least 4 msec before loss of regulation. Remote on/off Requires an external contact closure to inhibit outputs TTL logic goes high after the output is in regulation. It goes low when there is loss of regulation. DC OK Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Remote sense Environmental Specifications Operating temperature 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C -40C to 85C Storage temperature Electromagnetic susceptibility Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity Operating; non-condensing 10% to 90% RH Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 2 G peak 8Hz to 500Hz, operational Mating Connectors SK4,5,6 Molex 19141-0058 SK7 Control Signal Molex 90142-0010; PINS: 90119-2110 or Amp 87977-3; PINS: 87309-8 SK8 CN403 JST PHR-2; PINS: SPH-002T-PO.5S JST PHDR-10VS; PINS: JST 5PHD-002T-PO.5-L/P or Landwin 2050 S1000; PINS: 2053T011P Connector Kit #70-841-024, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02" (0.5mm) 3. Specifications are at factory settings unless otherwise stated. 4. Mounting screw maximum insertion depth is .12". 5. Warranty: 2 years 6. Weight: 3.016 lbs/1.18 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com GLS50 Series, GLS50-M Series Installation & Operating Instructions Installation & Safety To comply with the published safety standards, the following must be observed when using this power supply: 1. Maximum ambient temperature for the power supply must not exceed 50C. The power supply has been evaluated for use in 70C at half load (27.5) for GLS52 only; (30 W) for GLS53, GLS54, GLS55, and GLS58 only. 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03 for GLS52, GLS53, GLS54, GLS55, and GLS58; UL60601-1, EN60601-1, IEC60601-1, and CSA22.2 No. 606011-M90 for GLS52-M, GLS53-M, GLS54-M, GLS55-M, and GLS58-M. The safety requirements include creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. 3. This power supply is approved and certified for the rated voltage range of 100 V ac to 240 V ac. 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 5. The disconnection from the line must be in the end system. Output Ratings Model Convection Cooling Max. Output Current (A) Max. Output Power (W) 55 GLS52 (-M) +5 11.0 GLS53 (-M) +12 5.0 GLS54 (-M) +15 4.0 GLS55 (-M) +24 2.5 GLS58 (-M) +48 1.25 60 Connector PIN Designation Input Connector SK1 Output Connector 6. The internal fuse should only be replaced with a T3.15AH, 250 V ac, type TE5/392 manufactured by Wickmann. NOTE: The power supply has a fuse on the neutral line for GLS52-M, GLS53-M, GLS54-M, GLS55-M, and GLS58-M. Output Voltage (V) SK2 PIN GLS52 (-M) GLS53 (-M) GLS54 (-M) 1 Line 3 Neutral GLS58 (-M) PIN GLS52 (-M) GLS53 (-M) GLS54 (-M) GLS55 (-M) GLS58 (-M) 1 +5 V +12 V +15 V +24 V +48 V 2 +5 V +12 V +15 V +24 V +48 V 3 Common 4 Common 7. GLS52-M, GLS53-M, GLS54-M, GLS55-M, and GLS58-M have no patient applied part. 5 -Sense 8. This equipment is considered Class I according to protection against electric shock. 6 +Sense 9. This power supply is 2006/95/EC. GLS55 (-M) marked following the provisions of the Low Voltage Directive, For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. P/N: A272-176 Rev 2 01/11/10 Ref: LPS52/OP, LPS53/OP, LPS54/OP, LPS55/OP, LPS58/OP GLS50 Series, GLS50-M Series Installation & Operating Instructions Mechanical Outline & Dimensions Output Voltage Adjust Pot M1 ~ SK1 ~ F1 1 1 3 SK2 T2 1.72 [43.8] 2.00 [50.8] Earth GND M2 6 3.73 [94.7] 4.00 [101.6] Mounting Hole .16 [4.0] 4 X 1.30 [33.0] Top View .16 [4.0] Side View All dimensions are in inches [mm]. Maximum screw head diameter is .22 [5.6 mm]. Mounting holes M1 and M2 should be grounded for EMI purposes. Mounting hole M1 is an earth ground connection. CAUTION! Do not accidentally connect the ac connector to the dc output. GLS52, GLS53, GLS54, GLS55, GLS58, GLS52-M, GLS53-M, GLS54-M, GLS55-M, and GLS58-M are commercial designations of model numbers LPS52, LPS53, LPS54, LPS55, LPS58, LPS52-M, LPS53-M, LPS54-M, LPS55-M, and LPS58-M respectively. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. GLS50, GLS50-M Series Specifications Electrical Specifications Input Input range 90-264 Vac (wide range); 127-300 Vdc Frequency 47-440 Hz <60 A peak @ 230 Vac, cold start @ 25C Inrush current < 74 Watts Input power 80 - 85% typical at full load Efficiency FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE 0878 PT3 Class B conducted <0.5 mA @ 50/60 Hz, 264 Vac input for class I; < 0.25 mA @ 50/60 Hz; 264 Vac input for class II GLS50-M: 275 uA @ 50/60 Hz; 264 Vac input EMI/RFI Safety ground leakage current Output Maximum power 60 W convection; (GLS52, 55 W) Adjustment range 20% minimum 10/20 ms 115/230 Vac input line Short circuit protection on all outputs Case overload protected @ 110-160% of normal rating 30-50% above nominal output Hold-up time Overload protection Overvoltage protection Compensates for 0.5 lead V lead drop max. Will operate without remote sense. Reverse connection protected. Remote sense Environmental Specifications Operating temperature 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C. -20C start up. -40C to 85C Storage temperature Electromagnetic susceptibility Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity Operating; non-condensing 10% to 95% RH Vibration IEC68-2-6 to the levels of IEC721-3-2 > 550,000 hours at full load and 25C ambient conditions MTBF demonstrated Mating Connectors AC Input DC Outputs Molex 09-50-8031 (USA); 09-91-0300 (UK) PINS: 08-52-0113 Molex 09-50-8061 (USA); 09-91-0600 (UK) PINS: 08-52-0113 Connector Kit #70-841-006, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02" (0.5mm). 3. Mounting holes M1 and M2 should be grounded for EMI purposes. 4. Mounting hole M1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 Vac input, 25C unless otherwise stated. 6. Warranty: 2 year 7. Weight: 0.41 lb/0.18 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com GLS50 Series, GLS50-M Series Installation & Operating Instructions Installation & Safety To comply with the published safety standards, the following must be observed when using this power supply: 1. Maximum ambient temperature for the power supply must not exceed 50C. The power supply has been evaluated for use in 70C at half load (27.5) for GLS52 only; (30 W) for GLS53, GLS54, GLS55, and GLS58 only. 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03 for GLS52, GLS53, GLS54, GLS55, and GLS58; UL60601-1, EN60601-1, IEC60601-1, and CSA22.2 No. 606011-M90 for GLS52-M, GLS53-M, GLS54-M, GLS55-M, and GLS58-M. The safety requirements include creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. 3. This power supply is approved and certified for the rated voltage range of 100 V ac to 240 V ac. 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 5. The disconnection from the line must be in the end system. Output Ratings Model Convection Cooling Max. Output Current (A) Max. Output Power (W) 55 GLS52 (-M) +5 11.0 GLS53 (-M) +12 5.0 GLS54 (-M) +15 4.0 GLS55 (-M) +24 2.5 GLS58 (-M) +48 1.25 60 Connector PIN Designation Input Connector SK1 Output Connector 6. The internal fuse should only be replaced with a T3.15AH, 250 V ac, type TE5/392 manufactured by Wickmann. NOTE: The power supply has a fuse on the neutral line for GLS52-M, GLS53-M, GLS54-M, GLS55-M, and GLS58-M. Output Voltage (V) SK2 PIN GLS52 (-M) GLS53 (-M) GLS54 (-M) 1 Line 3 Neutral GLS58 (-M) PIN GLS52 (-M) GLS53 (-M) GLS54 (-M) GLS55 (-M) GLS58 (-M) 1 +5 V +12 V +15 V +24 V +48 V 2 +5 V +12 V +15 V +24 V +48 V 3 Common 4 Common 7. GLS52-M, GLS53-M, GLS54-M, GLS55-M, and GLS58-M have no patient applied part. 5 -Sense 8. This equipment is considered Class I according to protection against electric shock. 6 +Sense 9. This power supply is 2006/95/EC. GLS55 (-M) marked following the provisions of the Low Voltage Directive, For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. P/N: A272-176 Rev 2 01/11/10 Ref: LPS52/OP, LPS53/OP, LPS54/OP, LPS55/OP, LPS58/OP GLS50 Series, GLS50-M Series Installation & Operating Instructions Mechanical Outline & Dimensions Output Voltage Adjust Pot M1 ~ SK1 ~ F1 1 1 3 SK2 T2 1.72 [43.8] 2.00 [50.8] Earth GND M2 6 3.73 [94.7] 4.00 [101.6] Mounting Hole .16 [4.0] 4 X 1.30 [33.0] Top View .16 [4.0] Side View All dimensions are in inches [mm]. Maximum screw head diameter is .22 [5.6 mm]. Mounting holes M1 and M2 should be grounded for EMI purposes. Mounting hole M1 is an earth ground connection. CAUTION! Do not accidentally connect the ac connector to the dc output. GLS52, GLS53, GLS54, GLS55, GLS58, GLS52-M, GLS53-M, GLS54-M, GLS55-M, and GLS58-M are commercial designations of model numbers LPS52, LPS53, LPS54, LPS55, LPS58, LPS52-M, LPS53-M, LPS54-M, LPS55-M, and LPS58-M respectively. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. GLS50, GLS50-M Series Specifications Electrical Specifications Input Input range 90-264 Vac (wide range); 127-300 Vdc Frequency 47-440 Hz <60 A peak @ 230 Vac, cold start @ 25C Inrush current < 74 Watts Input power 80 - 85% typical at full load Efficiency FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE 0878 PT3 Class B conducted <0.5 mA @ 50/60 Hz, 264 Vac input for class I; < 0.25 mA @ 50/60 Hz; 264 Vac input for class II GLS50-M: 275 uA @ 50/60 Hz; 264 Vac input EMI/RFI Safety ground leakage current Output Maximum power 60 W convection; (GLS52, 55 W) Adjustment range 20% minimum 10/20 ms 115/230 Vac input line Short circuit protection on all outputs Case overload protected @ 110-160% of normal rating 30-50% above nominal output Hold-up time Overload protection Overvoltage protection Compensates for 0.5 lead V lead drop max. Will operate without remote sense. Reverse connection protected. Remote sense Environmental Specifications Operating temperature 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C. -20C start up. -40C to 85C Storage temperature Electromagnetic susceptibility Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity Operating; non-condensing 10% to 95% RH Vibration IEC68-2-6 to the levels of IEC721-3-2 > 550,000 hours at full load and 25C ambient conditions MTBF demonstrated Mating Connectors AC Input DC Outputs Molex 09-50-8031 (USA); 09-91-0300 (UK) PINS: 08-52-0113 Molex 09-50-8061 (USA); 09-91-0600 (UK) PINS: 08-52-0113 Connector Kit #70-841-006, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02" (0.5mm). 3. Mounting holes M1 and M2 should be grounded for EMI purposes. 4. Mounting hole M1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 Vac input, 25C unless otherwise stated. 6. Warranty: 2 year 7. Weight: 0.41 lb/0.18 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com GLS53-I Installation & Operating Instructions Mechanical Outline & Dimensions 1. Maximum ambient temperature for the power supply must not exceed 50C. The power supply has been evaluated for use in 70C at half load and 80C at quarter load. 3. This power supply is approved and certified for the rated voltage range of 100 V ac to 240 V ac. M1 ~ Earth GND M2 ~ F1 1 2.00 [50.8] 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03. The safety requirements include creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. Output Voltage Adjust Pot 1.72 [43.8] To comply with the published safety standards, the following must be observed when using this power supply: SK1 SK2 1 3 T2 6 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 3.73 [94.7] 4.00 [101.6] 5. The disconnection from the line must be in the end system. 6. The unit must be protected with dc rated fuse when operating in a dc input voltage. 7. The internal fuse should only be replaced with a 3.15A, 250 V ac, type TE5/392 manufactured by Wickmann. Mounting Hole .16 [4.0] 4 X Top View 8. This equipment is considered Class I according to protection against electric shock. marked following the provisions of the Low Voltage Directive, 10. For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. Output Ratings Side View Convection Cooling Output Voltage (V) Max. Output Current (A) Max. Output Power (W) 5.0 60 +12 .16 [4.0] 1.30 [33.0] 9. This power supply is 2006/95/EC. Connector PIN Designation Input Connector PIN Designation SK1 1 3 Line Neutral Output Connector PIN Designation SK2 1 2 3 4 5 6 +12 V +12 V Common Common -Sense +Sense All dimensions are in inches [mm]. Maximum screw head diameter is .22 [5.6 mm]. Mounting holes M1 and M2 should be grounded for EMI purposes. Mounting hole M1 is an earth ground connection. CAUTION! Do not accidentally connect the ac connector to the dc output. P/N: A272-207 Rev 0 6/29/09 Ref: 03370201560 (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions GLS53-I is a commercial designation of model number LPS53(-I). GLS50, GLS50-M Series Specifications Electrical Specifications Input Input range 90-264 Vac (wide range); 127-300 Vdc Frequency 47-440 Hz <60 A peak @ 230 Vac, cold start @ 25C Inrush current < 74 Watts Input power 80 - 85% typical at full load Efficiency FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE 0878 PT3 Class B conducted <0.5 mA @ 50/60 Hz, 264 Vac input for class I; < 0.25 mA @ 50/60 Hz; 264 Vac input for class II GLS50-M: 275 uA @ 50/60 Hz; 264 Vac input EMI/RFI Safety ground leakage current Output Maximum power 60 W convection; (GLS52, 55 W) Adjustment range 20% minimum 10/20 ms 115/230 Vac input line Short circuit protection on all outputs Case overload protected @ 110-160% of normal rating 30-50% above nominal output Hold-up time Overload protection Overvoltage protection Compensates for 0.5 lead V lead drop max. Will operate without remote sense. Reverse connection protected. Remote sense Environmental Specifications Operating temperature 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C. -20C start up. -40C to 85C Storage temperature Electromagnetic susceptibility Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity Operating; non-condensing 10% to 95% RH Vibration IEC68-2-6 to the levels of IEC721-3-2 > 550,000 hours at full load and 25C ambient conditions MTBF demonstrated Mating Connectors AC Input DC Outputs Molex 09-50-8031 (USA); 09-91-0300 (UK) PINS: 08-52-0113 Molex 09-50-8061 (USA); 09-91-0600 (UK) PINS: 08-52-0113 Connector Kit #70-841-006, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02" (0.5mm). 3. Mounting holes M1 and M2 should be grounded for EMI purposes. 4. Mounting hole M1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 Vac input, 25C unless otherwise stated. 6. Warranty: 2 year 7. Weight: 0.41 lb/0.18 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com GLS54, GLS54-M Installation & Operating Instructions Mechanical Outline & Dimensions 1. Maximum ambient temperature for the power supply must not exceed 50C. The power supply has been evaluated for use in 70C at half load (30 W) for GLS54 only. 3. This power supply is approved and certified for the rated voltage range of 100 V ac to 240 V ac. 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. M1 ~ Earth GND 2.00 [50.8] 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03 for GLS54; UL60601-1, EN60601-1, IEC60601-1, and CSA22.2 No. 60601-1-M90 for GLS54-M. The safety requirements include creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. Output Voltage Adjust Pot SK1 F1 1 1 3 5. The disconnection from the line must be in the end system. NOTE: The power supply has a fuse on the neutral line for GLS54-M. 8. This equipment is considered Class I according to protection against electric shock. 9. This power supply is 2006/95/EC. SK2 T2 6 3.73 [94.7] 4.00 [101.6] 6. The internal fuse should only be replaced with a T3.15AH, 250 V ac, type TE5/392 manufactured by Wickmann. 7. GLS54-M has no patient applied part. M2 ~ 1.72 [43.8] To comply with the published safety standards, the following must be observed when using this power supply: Mounting Hole .16 [4.0] 4 X Top View marked following the provisions of the Low Voltage Directive, 1.30 [33.0] 10. For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. .16 [4.0] Output Ratings Side View Convection Cooling Output Voltage (V) Max. Output Current (A) Max. Output Power (W) 4.0 60 +15 Connector PIN Designation Input Connector PIN Designation SK1 1 3 Line Neutral Output Connector PIN Designation SK2 1 2 3 4 5 6 +15 V +15 V Common Common -Sense +Sense GLS54/54-M are commercial designations of model numbers LPS54/54-M respectively. (c)2009 EGS Electrical Group. All rights reserved. Specifications subject to change without notice. All dimensions are in inches [mm]. Maximum screw head diameter is .22 [5.6 mm]. Mounting holes M1 and M2 should be grounded for EMI purposes. Mounting hole M1 is an earth ground connection. CAUTION! Do not accidentally connect the ac connector to the dc output. P/N: A272-184 Rev 0 4/28/09 Ref: LPS54/OP GLS50, GLS50-M Series Specifications Electrical Specifications Input Input range 90-264 Vac (wide range); 127-300 Vdc Frequency 47-440 Hz <60 A peak @ 230 Vac, cold start @ 25C Inrush current < 74 Watts Input power 80 - 85% typical at full load Efficiency FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE 0878 PT3 Class B conducted <0.5 mA @ 50/60 Hz, 264 Vac input for class I; < 0.25 mA @ 50/60 Hz; 264 Vac input for class II GLS50-M: 275 uA @ 50/60 Hz; 264 Vac input EMI/RFI Safety ground leakage current Output Maximum power 60 W convection; (GLS52, 55 W) Adjustment range 20% minimum 10/20 ms 115/230 Vac input line Short circuit protection on all outputs Case overload protected @ 110-160% of normal rating 30-50% above nominal output Hold-up time Overload protection Overvoltage protection Compensates for 0.5 lead V lead drop max. Will operate without remote sense. Reverse connection protected. Remote sense Environmental Specifications Operating temperature 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C. -20C start up. -40C to 85C Storage temperature Electromagnetic susceptibility Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity Operating; non-condensing 10% to 95% RH Vibration IEC68-2-6 to the levels of IEC721-3-2 > 550,000 hours at full load and 25C ambient conditions MTBF demonstrated Mating Connectors AC Input DC Outputs Molex 09-50-8031 (USA); 09-91-0300 (UK) PINS: 08-52-0113 Molex 09-50-8061 (USA); 09-91-0600 (UK) PINS: 08-52-0113 Connector Kit #70-841-006, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02" (0.5mm). 3. Mounting holes M1 and M2 should be grounded for EMI purposes. 4. Mounting hole M1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 Vac input, 25C unless otherwise stated. 6. Warranty: 2 year 7. Weight: 0.41 lb/0.18 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com GLS55, GLS55-M Installation & Operating Instructions Mechanical Outline & Dimensions 1. Maximum ambient temperature for the power supply must not exceed 50C. The power supply has been evaluated for use in 70C at half load (30 W) for GLS55 only. 3. This power supply is approved and certified for the rated voltage range of 100 V ac to 240 V ac. 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. M1 ~ Earth GND 2.00 [50.8] 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03 for GLS55; UL60601-1, EN60601-1, IEC60601-1, and CSA22.2 No. 60601-1-M90 for GLS55-M. The safety requirements include creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. Output Voltage Adjust Pot SK1 F1 1 1 3 5. The disconnection from the line must be in the end system. NOTE: The power supply has a fuse on the neutral line for GLS55-M. 8. This equipment is considered Class I according to protection against electric shock. 9. This power supply is 2006/95/EC. SK2 T2 6 3.73 [94.7] 4.00 [101.6] 6. The internal fuse should only be replaced with a T3.15AH, 250 V ac, type TE5/392 manufactured by Wickmann. 7. GLS55-M has no patient applied part. M2 ~ 1.72 [43.8] To comply with the published safety standards, the following must be observed when using this power supply: Mounting Hole .16 [4.0] 4 X Top View marked following the provisions of the Low Voltage Directive, 1.30 [33.0] 10. For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. .16 [4.0] Output Ratings Output Voltage (V) +24 Convection Cooling Max. Output Current (A) 2.5 Max. Output Power (W) 60 Connector PIN Designation Input Connector SK1 Output Connector SK2 PIN 1 3 PIN 1 2 3 4 5 6 Designation Line Neutral Designation +24 V +24 V Common Common -Sense +Sense GLS55/55-M are commercial designations of model numbers LPS55/55-M respectively. (c)2009 EGS Electrical Group. All rights reserved. Specifications subject to change without notice. Side View All dimensions are in inches [mm]. Maximum screw head diameter is .22 [5.6 mm]. Mounting holes M1 and M2 should be grounded for EMI purposes. Mounting hole M1 is an earth ground connection. CAUTION! Do not accidentally connect the ac connector to the dc output. P/N: A272-176 Rev 1 4/24/09 Ref: LPS55/OP GLS50, GLS50-M Series Specifications Electrical Specifications Input Input range 90-264 Vac (wide range); 127-300 Vdc Frequency 47-440 Hz <60 A peak @ 230 Vac, cold start @ 25C Inrush current < 74 Watts Input power 80 - 85% typical at full load Efficiency FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE 0878 PT3 Class B conducted <0.5 mA @ 50/60 Hz, 264 Vac input for class I; < 0.25 mA @ 50/60 Hz; 264 Vac input for class II GLS50-M: 275 uA @ 50/60 Hz; 264 Vac input EMI/RFI Safety ground leakage current Output Maximum power 60 W convection; (GLS52, 55 W) Adjustment range 20% minimum 10/20 ms 115/230 Vac input line Short circuit protection on all outputs Case overload protected @ 110-160% of normal rating 30-50% above nominal output Hold-up time Overload protection Overvoltage protection Compensates for 0.5 lead V lead drop max. Will operate without remote sense. Reverse connection protected. Remote sense Environmental Specifications Operating temperature 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C. -20C start up. -40C to 85C Storage temperature Electromagnetic susceptibility Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity Operating; non-condensing 10% to 95% RH Vibration IEC68-2-6 to the levels of IEC721-3-2 > 550,000 hours at full load and 25C ambient conditions MTBF demonstrated Mating Connectors AC Input DC Outputs Molex 09-50-8031 (USA); 09-91-0300 (UK) PINS: 08-52-0113 Molex 09-50-8061 (USA); 09-91-0600 (UK) PINS: 08-52-0113 Connector Kit #70-841-006, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02" (0.5mm). 3. Mounting holes M1 and M2 should be grounded for EMI purposes. 4. Mounting hole M1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 Vac input, 25C unless otherwise stated. 6. Warranty: 2 year 7. Weight: 0.41 lb/0.18 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com GLS58, GLS58-M Installation & Operating Instructions Mechanical Outline & Dimensions 1. Maximum ambient temperature for the power supply must not exceed 50C. The power supply has been evaluated for use in 70C at half load (30 W) for GLS58 only. 3. This power supply is approved and certified for the rated voltage range of 100 V ac to 240 V ac. 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. M1 ~ Earth GND 2.00 [50.8] 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03 for GLS58; UL60601-1, EN60601-1, IEC60601-1, and CSA22.2 No. 60601-1-M90 for GLS58-M. The safety requirements include creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. Output Voltage Adjust Pot SK1 F1 1 1 3 5. The disconnection from the line must be in the end system. NOTE: The power supply has a fuse on the neutral line for GLS58-M. 8. This equipment is considered Class I according to protection against electric shock. 9. This power supply is 2006/95/EC. SK2 T2 6 3.73 [94.7] 4.00 [101.6] 6. The internal fuse should only be replaced with a T3.15AH, 250 V ac, type TE5/392 manufactured by Wickmann. 7. GLS58-M has no patient applied part. M2 ~ 1.72 [43.8] To comply with the published safety standards, the following must be observed when using this power supply: Mounting Hole .16 [4.0] 4 X Top View marked following the provisions of the Low Voltage Directive, 1.30 [33.0] 10. For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. .16 [4.0] Output Ratings Side View Convection Cooling Output Voltage (V) Max. Output Current (A) Max. Output Power (W) 1.25 60 +48 Connector PIN Designation Input Connector PIN Designation SK1 1 3 Line Neutral Output Connector PIN Designation SK2 1 2 3 4 5 6 +48 V +48 V Common Common -Sense +Sense GLS58/58-M are commercial designations of model numbers LPS58/58-M respectively. (c)2009 EGS Electrical Group. All rights reserved. Specifications subject to change without notice. All dimensions are in inches [mm]. Maximum screw head diameter is .22 [5.6 mm]. Mounting holes M1 and M2 should be grounded for EMI purposes. Mounting hole M1 is an earth ground connection. CAUTION! Do not accidentally connect the ac connector to the dc output. P/N: A272-185 Rev 0 4/28/09 Ref: LPS58/OP GLS50, GLS50-M Series Specifications Electrical Specifications Input Input range 90-264 Vac (wide range); 127-300 Vdc Frequency 47-440 Hz <60 A peak @ 230 Vac, cold start @ 25C Inrush current < 74 Watts Input power 80 - 85% typical at full load Efficiency FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE 0878 PT3 Class B conducted <0.5 mA @ 50/60 Hz, 264 Vac input for class I; < 0.25 mA @ 50/60 Hz; 264 Vac input for class II GLS50-M: 275 uA @ 50/60 Hz; 264 Vac input EMI/RFI Safety ground leakage current Output Maximum power 60 W convection; (GLS52, 55 W) Adjustment range 20% minimum 10/20 ms 115/230 Vac input line Short circuit protection on all outputs Case overload protected @ 110-160% of normal rating 30-50% above nominal output Hold-up time Overload protection Overvoltage protection Compensates for 0.5 lead V lead drop max. Will operate without remote sense. Reverse connection protected. Remote sense Environmental Specifications Operating temperature 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C. -20C start up. -40C to 85C Storage temperature Electromagnetic susceptibility Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity Operating; non-condensing 10% to 95% RH Vibration IEC68-2-6 to the levels of IEC721-3-2 > 550,000 hours at full load and 25C ambient conditions MTBF demonstrated Mating Connectors AC Input DC Outputs Molex 09-50-8031 (USA); 09-91-0300 (UK) PINS: 08-52-0113 Molex 09-50-8061 (USA); 09-91-0600 (UK) PINS: 08-52-0113 Connector Kit #70-841-006, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02" (0.5mm). 3. Mounting holes M1 and M2 should be grounded for EMI purposes. 4. Mounting hole M1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 Vac input, 25C unless otherwise stated. 6. Warranty: 2 year 7. Weight: 0.41 lb/0.18 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com GLS60 Series, GLS60-M Series Installation & Operating Instructions Mechanical Outline To comply with the published safety standards, the following must be observed when using this power supply: M1 M2 GND 1. Maximum ambient temperature for the power supply must not exceed 50C. R16 C27 C32 IC4 R32 IC1 W4 D1 T1 1 D16A Connector PIN Designation Input Connector PIN GLS62 SK1 Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions GLS64 (-M) GLS65 (-M) Neutral 3 Output Connector Line PIN GLS62 GLS63 (-M) GLS64 (-M) GLS65 (-M) +5 V +12 V +15 V +24 V 1 3 SK2 4 5 Common 6 SK201 1 +Sense 2 -Sense Note: Mounting holes M1 and M2 should be grounded for EMI purposes. Mounting hole M1 is a safety ground connection. Output Ratings marked following the provisions of the Low Voltage Directive, 13. For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. GLS63 (-M) 1 11. This equipment is considered Class I according to protection against electrick shock. 12. This power supply is 2006/95/EC. 6 3 D15 10. This power supply is not suitable for direct contact to the patient. FB1 9. The internal fuse should only be replaced with a 3.15 A, 250 V ac, type SP0001.1009 manufactured by Schurter AG, type 2163.15 manufactured by Littelfuse, or type S501 manufactured by Cooper. W3 SK1 2 8. When operating with a dc input voltage range, the unit input must be protected by a dc rated fuse in the end-use installation system. R31 W6 C33 7. Hazardous voltages exist in the primary circuits. Disconnect the power supply before servicing. J8 6. The disconnection from the line must be in the end system. 1 SK2 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 5. The earth ground wire must be connected only to the point marked with the earth ground symbol (on the unit). SK201 V Adj. Pot C21 3. The power supply's rated input voltage is automatically selected for GLS62, GLS63, GLS64, and GLS65. Please refer to the specification sheet for the input voltage range. GLS63-M, GLS64-M, and GLS65-M are approved and certified for the rated voltage range of 100 V ac to 250 V ac and/or 140 V dc to 300 V dc. W2 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03 for GLS62, GLS63, GLS64, and GLS65; UL60601-1, EN60601-1, IEC60601-1, and CSA22.2 No. 60601-1-M90 for GLS63-M, GLS64-M, and GLS65-M. The safety requirements include creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. Convection Cooling Model Output Voltage (V) Max. Output Current (A) GLS62 +5 12.0 GLS63 (-M) +12 5.0 GLS64 (-M) +15 4.0 GLS65 (-M) +24 2.5 Max. Output Power (W) 30 CFM Forced Air Cooling Max. Output Current (A) Max. Output Power (W) 16.0 60 6.7 5.3 80 3.3 P/N: A272-198 Rev 0 5/12/09 Ref: 03361001333/03366200541 GLS60 Series, GLS60-M Series Installation & Operating Instructions Mechanical Dimensions Typical Ventilation Setup Bottom View Top View 3.00 [76.2] 2.55 [64.8] .22 [5.6] FAN 6.69 [170.0] AIR FLOW T1 UNIT 4.55 [115.6] 1.08 [27.5] MAX Side View 7.28 [185.0] 4.33 [110.0] Side View 4.33 [110.0] FAN 5.00 [127.0] 1.57 [40.0] .22 [5.6] AIR FLOW .12 [3.0] MAX .06 [1.6] UNIT All dimensions are in inches [mm] Mounting hole diameter (4X): 0.15 [3.81 mm] Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions. GLS62, GLS63, GLS64, and GLS65 are commercial designations of model numbers LPS62, LPS63, LPS64, and LPS65 respectively. GLS63-M, GLS64-M, and GLS65-M are commercial designations of model numbers LPS63-M, LPS64-M, and LPS65-M respectively. Fan: MINEBEA 3110NL-04W-B30 Fan Input: 12 V dc NOTE: Dimensions and fan used are for reference only (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. GLS60 Series Specifications Electrical Specifications Input 85-264 Vac (wide range); 120-300 Vdc Input range 47-440 Hz Frequency Inrush current <18 A peak @ 115 Vac, <36 A peak @ 230 Vac, cold start @ 25C Input current 1.5 A max. (RMS) @ 115 Vac 70% typical at full load FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE 0878 PT3 Class B conducted Efficiency EMI filter Safety ground leakage current <0.5 mA @ 50/60 Hz, 264 Vac input Output Maximum power 60 W convection; 80 W with 30 CFM forced air Adjustment range -5, 10% min. 20 ms @ 60 W load, 115 Vac nominal line Short circuit protection on all outputs. Case overload protected @ 110-145% above peak rating 5 V output; 5.7 to 6.7 Vdc; Other outputs 10% to 25% above nominal output Hold-up time Overload protection Overvoltage protection Compensates for 0.5 V lead drop minimum, will operate without remote sense connected. Reverse connection protected Remote sense Environmental Specifications Operating temperature 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C, -20C startup Storage temperature Temperature coefficient Electromagnetic susceptibility -40C to 85C 0.04% per C Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Humidity Operating; non-condensing 5% to 95% RH Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5 Hz to 500 Hz, operational >550,000 hours at full load and 25C ambient conditions MTBF demonstrated Mating Connectors AC Input DC Outputs Remote Sense Molex 09-50-8031 (USA) Not required for (-T) option 09-91-0300 (UK); PINS: 08-58-0111 Molex 09-50-8061 (USA) Not required for (-T) option 09-91-0600 (UK); PINS: 08-58-0113 Molex 22-01-2025 PINS: 08-52-0113 Connector Kit #70-841-006, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02" (0.5mm). 3. Mounting holes M1 and M2 should be grounded for EMI purposes. 4. Mounting hole M1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 Vac input, 25C unless otherwise stated. 6. Warranty: 2 year 7. Weight: 0.75 lb/0.34 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com Power Derating Curve 80W 30 CFM Forced Air Cooling Output Power (Watts) 60W Natural Convection Cooling 40W 40W 30W 20W 0W 0C 10C 20C 30C 40C 50C 60C TA - Ambient Temperature - C 70C GLT20 Series Installation & Operating Instructions Installation & Safety Mechanical Outline M1 To comply with the published safety standards, the following must be observed when using this power supply: M2 GND 1. Maximum ambient temperature for the power supply must not exceed 50C. -+ 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03; including the requirements for creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. 1 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 6. Hazardous voltages exist in the primary circuits. Disconnect the power supply before servicing. 7. When operating with a dc input voltage range, the unit input must be protected by a dc rated fuse in the end-use installation system. 8. The internal fuse should only be replaced with a 2.5 A, 250 V ac, type SP0001.1008 manufactured by Schurter AG or type 21602.5 manufactured by Littelfuse. 9. This equipment is considered Class I according to protection against electric shock. 10. This power supply is 2006/95/EC. marked following the provisions of the Low Voltage Directive, For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. SK201 1 2 3 4 5 6 3 SK1 3. The power supply's rated input voltage is automatically selected. Please refer to the specification sheet for the input voltage range. 5. The earth ground wire must be connected only to the point marked with the earth ground symbol (on the unit). Voltage Adj. Pot SK2 Connector PIN Designation Input Connector PIN GLT22 GLT23 GLT24 GLT25 1 Line 3 Neutral Output Connector PIN GLT22 GLT23 GLT24 GLT25 1 +12 V +15 V 2 +5 V 3 SK2 4 Common 5 6 -12 V -12 V -5 V -15 V 1 +Sense SK201 2 -Sense Note: Mounting holes M1 and M2 should be grounded for EMI purposes. Mounting hole M1 is an earth ground connection. SK1 Output Ratings Model GLT22 GLT23 GLT24 GLT25 Output Voltage (V) +5 +12 -12 +5 +12 -12 +5 +12 -5 +5 +15 -15 Convection Cooling Max. Output Current (A) 3.0 1.5 0.5 4.0 0.5 0.5 3.0 1.5 0.5 3.0 1.5 0.5 Max. Output Power (W) 25 30 CFM Forced Air Cooling Max. Output Current (A) 4.0 2.0 0.7 5.0 0.7 0.7 4.0 2.0 0.7 4.0 2.0 0.7 Max. Output Power (W) 40 P/N: A272-179 Rev 1 01/06/10 Ref: 03361001733 GLT20 Series Installation & Operating Instructions Mechanical Dimensions Typical Ventilation Setup .15 [3.81] diameter (4X) .22 [5.6] 3.00 [76.2] 2.55 [64.8] FAN 6.69 [170.0] AIR FLOW T1 UNIT 4.55 [115.6] 5.00 [127.0] 7.28 [185.0] 1.57 [40.0] .22 [5.6] 4.33 [110.0] Top View .12 [3.0] MAX .06 [1.6] 1.08 [27.5] MAX 4.33 [110.0] FAN Bottom View AIR FLOW UNIT Side View All dimensions are in inches [mm] Side View Fan: MINEBEA 3110NL-04W-B30 Fan Input: 12 V dc NOTE: Dimensions and fan used are for reference only GLT22, GLT23, GLT24, and GLT25 are commercial designations of model numbers LPT22, LPT23, LPT24, and LPT25 respectively. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. GLT20 Series Specifications Electrical Specifications Input Input range 85-264 Vac; 120-300 Vdc Frequency 47-440 Hz Inrush current <15 A peak @ 115 Vac; <30 A peak @ 230 Vac, cold start @ 25C Input current 1 A max. (RMS) @ 115 Vac 70% typical at full load FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE 0878 PT3 Class B conducted Efficiency EMI filter Safety ground leakage current <0.5 mA @ 50/60 Hz, 264 Vac input Output Maximum power 25 W for convection; 40 W with 30 CFM forced air Cross regulation 2% on output 1; 5% on outputs 2, 3 Adjustment range -5, +10% minimum 20 ms @ 25 W load, 115 Vac nominal line Short circuit protection on all outputs Case overload protected @ 110-145% above peak rating Hold-up time Overload protection 5.7 to 6.7 Vdc on the main output Overvoltage protection Minimum Load Remote Sense 0.3 A first output, 0.1 A second output: GLT22, GLT24, GLT25; 0.4A first output: GLT23 Compensates for 0.5 V lead drop minimum;Will operate without remote sense connected. Reverse connection protected. Environmental Specifications Operating temperature 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C, -20C start up. Storage temperature -40C to 85C Temperature coefficient .04% per C Electromagnetic susceptibility Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Humidity Operating; non-condensing 5% to 95% Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5 Hz to 500 Hz, operational >550,000 hours at full load and 25C ambient conditions MTBF demonstrated Mating Connectors Power Derating Curve AC Input Molex 09-50-8031 (USA) Not required for (-T) option 09-91-0300 (UK); PINS: 08-52-0113 DC Outputs Molex 09-50-8061 (USA) Not required for (-T) option 09-91-0600 (UK); PINS: 08-52-0113 Remote Sense Molex 22-01-2025; PINS: 08-52-0123 Connector Kit #70-841-006, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02" (0.5mm). 3. Mounting holes M1 and M2 should be grounded for EMI purposes. 4. Mounting hole M1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 Vac input, 25C unless otherwise stated. 6. Warranty: 2 year 7. Weight: 0.5lb/0.23kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com Power Derating Curve 40W 30 CFM Forced Air Cooling 30W Output Power 25W (Watts) 20W 20W Natural Convection Cooling 10W 12.5W 0W 0C 10C 20C 30C 40C 50C 60C TA - Ambient Temperature - C 70C GLT40 Series, GLT40-M Series Installation & Operating Instructions Installation & Safety Mechanical Outline M2 M1 To comply with the published safety standards, the following must be observed when using this power supply: 1. Maximum ambient temperature for the power supply must not exceed 50C. 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03 for GLT42, GLT43, GLT44, GLT45, and GLT46; UL60601-1, EN60601-1, IEC60601-1, and CSA22.2 No. 60601-1M90 for GLT42-M and GLT45-M. The safety requirements include creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. Voltage Adj. Pot 1 2 3 4 SK1 SK2 5 3 6 1 3. The power supply's rated input voltage is automatically selected. Please refer to the specification sheet for the input voltage range. 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 5. The earth ground wire must be connected only to the point marked with the earth ground symbol (on the unit). 6. Hazardous voltages exist in the primary circuits. Disconnect the power supply before servicing. 7. When operating with a dc input voltage range, the unit input must be protected by a dc rated fuse in the end-use installation system. 8. The internal fuse should only be replaced with a 2.5 A, 250 V ac, type SP0001.1008 manufactured by Schurter AG or type 21602.5 manufactured by Littelfuse. Connector PIN Designation Input Connector PIN GLT42 (-M) GLT43 GLT44 GLT45 (-M) GLT46 1 Line 3 Neutral Output Connector PIN GLT42 (-M) GLT43 GLT44 GLT45 (-M) GLT46 1 +12 V +15 V +24 V 2 +5 V 3 SK2 4 Common 5 6 -12 V -12 V -5 V -15 V +12 V 1 +Sense SK201 2 -Sense NOTE: Mounting holes M1 and M2 should be grounded for EMI purposes. Mounting hole M1 is an earth ground connection. SK1 9. GLT42-M and GLT45-M have no patient applied part. Output Ratings 10. This equipment is considered Class I according to protection against electric shock. 11. This power supply is 2006/95/EC. marked following the provisions of the Low Voltage Directive, For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. Model GLT42 (-M) GLT43 GLT44 GLT45 (-M) GLT46 Output Voltage (V) +5 +12 -12 +5 +12 -12 +5 +12 -5 +5 +15 -15 +5 +24 +12 Convection Cooling Max. Output Current (A) 4.0 2.0 0.5 6.0 0.5 0.5 4.0 2.0 0.5 4.0 2.0 0.5 4.0 1.0 0.5 Max. Output Power (W) 40 30 CFM Forced Air Cooling Max. Output Current (A) 5.0 2.5 0.7 8.0 0.7 0.7 5.0 2.5 0.7 5.0 2.5 0.7 5.0 1.5 0.7 Max. Output Power (W) 55 P/N: A272-181 Rev 1 01/06/10 Ref: 03361001284/03366200501 GLT40 Series, GLT40-M Series Installation & Operating Instructions Mechanical Dimensions Typical Ventilation Setup .15 [3.81] diameter (4X) .22 [5.6] 3.00 [76.2] 2.55 [64.8] FAN 6.69 [170.0] AIR FLOW T1 UNIT 4.55 [115.6] 5.00 [127.0] 7.28 [185.0] 1.57 [40.0] .22 [5.6] 4.33 [110.0] Top View .12 [3.0] MAX .06 [1.6] 1.08 [27.5] MAX 4.33 [110.0] FAN Bottom View AIR FLOW UNIT Side View All dimensions are in inches [mm] Side View Fan: MINEBEA 3110NL-04W-B30 Fan Input: 12 V dc NOTE: Dimensions and fan used are for reference only GLT42, GLT43, GLT44, GLT45, GLT46, GLT42-M, and GLT45-M are commercial designations of model numbers LPT42, LPT43, LPT44, LPT45, LPT46, LPT42-M, and LPT45-M respectively. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. GLT40, GLT40-M Series Specifications Electrical Specifications Input Input range 85-264 Vac; 120-300 Vdc Frequency 47-440 Hz Inrush current <18 A peak @ 115 Vac; <36 A peak @ 230 Vac, cold start @ 25C Input current 1 A max. (RMS) @ 115 Vac 70% typical at full load FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE 0878 PT3 Class B conducted <0.5 mA @ 50/60 Hz, 264 Vac input; GLT40-M: <75A @ 50/60 Hz, 264 Vac input Efficiency EMI Safety ground leakage current Output Maximum power 40 W convection; 55 W with 30 CFM forced air Cross regulation 2% on output 1; 5% on outputs 2, 3 Adjustment range -5, +10% minimum Hold-up time Overload protection Overvoltage protection Minimum Load Remote sense 20 ms @ 40 W load, 115 Vac nominal line Short circuit protection on all outputs. Case overload protected @ 110-145% above peak rating 5.7 to 6.7 Vdc on the main output 0.4 A for first output, 0.2 A for second outputs: GLT42, GLT44, GLT45; 0.5 A for the 1st output of GLT43; 0.4 A for first output, 0.1 A for second outputs: GLT46 Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Environmental Specifications Operating temperature 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C; -20C start up. Storage temperature -40C to 85C Temperature coefficient Electromagnetic susceptibility .04% per C Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Humidity Operating; non-condensing 5% to 95% Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75 G peak 5 Hz to 500 Hz, operational >550,000 hours at full load and 25C ambient conditions MTBF demonstrated Mating Connectors AC Input DC Outputs Remote Sense Power Derating Curve Molex 09-50-8031 (USA) Not required for (-T) option; 09-91-0300 (UK) PINS: 08-52-0113 Molex 09-50-8061 (USA) Not required for (-T) option; 09-91-0600 (UK) PINS: 08-52-0113 Molex 22-01-2025; PINS 08-52-0123 Power Derating Curve 55W 30 CFM Forced Air Cooling 40W Connector Kit #70-841-006, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02" (0.5mm). Output Power (Watts) 30W 27.5W Natural Convection Cooling 20W 3. Mounting holes M1 and M2 should be grounded for EMI purposes. 4. Mounting hole M1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 Vac input, 25C unless otherwise stated. 10W 0W 0C 10C 6. Warranty: 2 year 20W 20C 30C 40C 50C 60C TA - Ambient Temperature - C 7. Weight: 0.5 lb/0.23 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com 70C GLT50 Series, GLT50-M Series Installation & Operating Instructions Installation & Safety To comply with the published safety standards, the following must be observed when using this power supply: Output Ratings Output Voltage (V) +5 8.0 GLT52 (-M) +12 3.0 -12 0.5 +5 8.0 +15 2.4 -15 0.5 1. Maximum ambient temperature for the power supply must not exceed 50C. 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03 for GLT52, GLT53, and GLT54; UL60601-1, EN60601-1, IEC60601-1, and CSA22.2 No. 60601-1-M90 for GLT52-M, GLT53-M, and GLT54-M. The safety requirements include creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. 3. This power supply is approved and certified for the rated voltage range of 100 V ac to 240 V ac. Convection Cooling Model GLT53 (-M) GLT54 (-M) Max. Output Current (A) +5 8.0 +24 1.5 +12 0.5 Max. Output Power (W) 55 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 5. The disconnection from the line must be in the end system. 6. The internal fuse should only be replaced with a T2.5AL, 250 V ac, type 392 manufactured by Wickmann. NOTE: The power supply has a fuse on the neutral line for GLT52-M, GLT53-M, and GLT54-M. 7. GLT52-M, GLT53-M, and GLT54-M have no patient applied part. Connector PIN Designation Input Connector SK1 Output Connector PIN GLT52 (-M) GLT53 (-M) 1 Neutral 3 Line PIN GLT52 (-M) GLT53 (-M) 8. This equipment is considered Class I according to protection against electric shock. 1 9. This power supply is 2006/95/EC. 2 +5 V 3 Common marked following the provisions of the Low Voltage Directive, For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. SK2 GLT54 (-M) GLT54 (-M) +5 V 4 Common 5 -12 V -15 V +12 V 6 +12 V +15 V +24 V P/N: A272-186 Rev 1 01/11/10 Ref: LPT52/OP, LPT53/OP, LPT54/OP GLT52, GLT52-M Installation & Operating Instructions Mechanical Outline & Dimensions M1 M2 1 3 1 GND Mounting hole .16 [4.0] 4X SK2 2.00 [50.8] SK1 1.72 [43.8] 6 3.73 [94.7] 4.00 [101.6] 1.30 [32.9] Top View .197 [5.0] minimum Side View All dimensions are in inches [mm]. Maximum screw diameter is .22 [5.6 mm]. Mounting holes M1 and M2 should be grounded for EMI purposes. Mounting hole M1 is an earth ground connection. CAUTION! Do not accidentally connect the ac connector to the dc output. GLT52, GLT53, GLT54, GLT52-M, GLT53-M, and GLT54-M are commercial designations of model numbers LPT52, LPT53, LPT54, LPT52-M, LPT53-M, and LPT54-M respectively. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. GLT50, GLT50-M Series Specifications Electrical Specifications Input Input range 90-264 Vac (wide range); 127-300 Vdc Frequency 47-440 Hz <60 A peak @ 230 Vac, cold start @ 25C Inrush current 80% typical at full load FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted <0.5 mA @ 50/60 Hz, 264 Vac input; GLT50-M: <275A @ 50/60 Hz, 264 Vac input Efficiency EMI/RFI Safety ground leakage current Output 55 W convection Maximum power 10/20 ms 115/230 Vac input line Short circuit protection on all outputs. Case overload protected @ 110-160% of normal rating 30-50% above nominal output Hold-up time Overload protection Overvoltage protection 0.5 A for first output, 0.1 A for second output Minimum Load Environmental Specifications Operating temperature 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C. -20C start up. -40C to 85C Storage temperature Electromagnetic susceptibility Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity Operating; non-condensing 10% to 95% RH Vibration IEC68-2-6 to the levels of IEC721-3-2 > 550,000 hours at full load and 25C ambient conditions MTBF demonstrated Mating Connectors AC Input DC Outputs Molex 09-50-8031 (USA); 09-91-0300 (UK) PINS: 08-52-0113 Molex 09-50-8061 (USA); 09-91-0600 (UK) PINS: 08-52-0113 Connector Kit #70-841-006, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02" (0.5mm). 3. Mounting holes M1 and M2 should be grounded for EMI purposes. 4. Mounting hole M1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 Vac input, 25C unless otherwise stated. 6. Warranty: 2 year 7. Weight: 0.45 lb/0.20 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com GLT53, GLT53-M Installation & Operating Instructions Mechanical Outline & Dimensions M1 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03 for GLT53; UL60601-1, EN60601-1, IEC60601-1, and CSA22.2 No. 60601-1-M90 for GLT53-M. The safety requirements include creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. 6 SK1 3. This power supply is approved and certified for the rated voltage range of 100 V ac to 240 V ac. 6. The internal fuse should only be replaced with a T2.5AL, 250 V ac, type 392 manufactured by Wickmann. 1 3 Mounting hole .16 [4.0] 4X NOTE: The power supply has a fuse on the neutral line for GLT53-M. 4.00 [101.6] 8. This equipment is considered Class I according to protection against electric shock. Convection Cooling Max. Output Current (A) Max. Output Power (W) 8.0 2.4 0.5 55 +5 +15 -15 Connector PIN Designation SK1 Output Connector SK2 1.30 [32.9] Output Ratings Input Connector Top View marked following the provisions of the Low Voltage Directive, 10. For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. Output Voltage (V) SK2 3.73 [94.7] 7. GLT53-M has no patient applied part. 9. This power supply is 2006/95/EC. 1 GND 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 5. The disconnection from the line must be in the end system. M2 2.00 [50.8] 1. Maximum ambient temperature for the power supply must not exceed 50C. 1.72 [43.8] To comply with the published safety standards, the following must be observed when using this power supply: PIN 1 3 PIN 1 2 3 4 5 6 Designation Neutral Line Designation +5 V +5 V Common Common -15 +15 GLT53/53-M are commercial designations of model numbers LPT53/53-M respectively. (c)2009 EGS Electrical Group. All rights reserved. Specifications subject to change without notice. Side View .197 [5.0] minimum All dimensions are in inches [mm]. Maximum screw diameter is .22 [5.6 mm]. Mounting holes M1 and M2 should be grounded for EMI purposes. Mounting hole M1 is an earth ground connection. CAUTION! Do not accidentally connect the ac connector to the dc output. P/N: A272-187 Rev 0 4/28/09 Ref: LPT53/OP GLT50, GLT50-M Series Specifications Electrical Specifications Input Input range 90-264 Vac (wide range); 127-300 Vdc Frequency 47-440 Hz <60 A peak @ 230 Vac, cold start @ 25C Inrush current 80% typical at full load FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted <0.5 mA @ 50/60 Hz, 264 Vac input; GLT50-M: <275A @ 50/60 Hz, 264 Vac input Efficiency EMI/RFI Safety ground leakage current Output 55 W convection Maximum power 10/20 ms 115/230 Vac input line Short circuit protection on all outputs. Case overload protected @ 110-160% of normal rating 30-50% above nominal output Hold-up time Overload protection Overvoltage protection 0.5 A for first output, 0.1 A for second output Minimum Load Environmental Specifications Operating temperature 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C. -20C start up. -40C to 85C Storage temperature Electromagnetic susceptibility Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity Operating; non-condensing 10% to 95% RH Vibration IEC68-2-6 to the levels of IEC721-3-2 > 550,000 hours at full load and 25C ambient conditions MTBF demonstrated Mating Connectors AC Input DC Outputs Molex 09-50-8031 (USA); 09-91-0300 (UK) PINS: 08-52-0113 Molex 09-50-8061 (USA); 09-91-0600 (UK) PINS: 08-52-0113 Connector Kit #70-841-006, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02" (0.5mm). 3. Mounting holes M1 and M2 should be grounded for EMI purposes. 4. Mounting hole M1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 Vac input, 25C unless otherwise stated. 6. Warranty: 2 year 7. Weight: 0.45 lb/0.20 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com GLT54, GLT54-M Installation & Operating Instructions Mechanical Outline & Dimensions M1 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03 for GLT54; UL60601-1, EN60601-1, IEC60601-1, and CSA22.2 No. 60601-1-M90 for GLT54-M. The safety requirements include creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. M2 6 SK1 1 3 1 GND 3. This power supply is approved and certified for the rated voltage range of 100 V ac to 240 V ac. SK2 2.00 [50.8] 1. Maximum ambient temperature for the power supply must not exceed 50C. 1.72 [43.8] To comply with the published safety standards, the following must be observed when using this power supply: 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. 5. The disconnection from the line must be in the end system. 6. The internal fuse should only be replaced with a T2.5AL, 250 V ac, type 392 manufactured by Wickmann. Mounting hole .16 [4.0] 4X 3.73 [94.7] 4.00 [101.6] NOTE: The power supply has a fuse on the neutral line for GLT54-M. 7. GLT54-M has no patient applied part. Top View 8. This equipment is considered Class I according to protection against electric shock. marked following the provisions of the Low Voltage Directive, 10. For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. Output Ratings Output Voltage (V) +5 +24 +12 Convection Cooling Max. Output Current (A) 8.0 1.5 0.5 Max. Output Power (W) 55 Connector PIN Designation Input Connector SK1 Output Connector SK2 1.30 [32.9] 9. This power supply is 2006/95/EC. PIN 1 3 PIN 1 2 3 4 5 6 Designation Neutral Line Designation +5 V +5 V Common Common +12 +24 GLT54/54-M are commercial designations of model numbers LPT54/54-M respectively. (c)2009 EGS Electrical Group. All rights reserved. Specifications subject to change without notice. Side View .197 [5.0] minimum All dimensions are in inches [mm]. Maximum screw diameter is .22 [5.6 mm]. Mounting holes M1 and M2 should be grounded for EMI purposes. Mounting hole M1 is an earth ground connection. CAUTION! Do not accidentally connect the ac connector to the dc output. P/N: A272-188 Rev 0 4/28/09 Ref: LPT54/OP GLT50, GLT50-M Series Specifications Electrical Specifications Input Input range 90-264 Vac (wide range); 127-300 Vdc Frequency 47-440 Hz <60 A peak @ 230 Vac, cold start @ 25C Inrush current 80% typical at full load FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted <0.5 mA @ 50/60 Hz, 264 Vac input; GLT50-M: <275A @ 50/60 Hz, 264 Vac input Efficiency EMI/RFI Safety ground leakage current Output 55 W convection Maximum power 10/20 ms 115/230 Vac input line Short circuit protection on all outputs. Case overload protected @ 110-160% of normal rating 30-50% above nominal output Hold-up time Overload protection Overvoltage protection 0.5 A for first output, 0.1 A for second output Minimum Load Environmental Specifications Operating temperature 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C. -20C start up. -40C to 85C Storage temperature Electromagnetic susceptibility Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity Operating; non-condensing 10% to 95% RH Vibration IEC68-2-6 to the levels of IEC721-3-2 > 550,000 hours at full load and 25C ambient conditions MTBF demonstrated Mating Connectors AC Input DC Outputs Molex 09-50-8031 (USA); 09-91-0300 (UK) PINS: 08-52-0113 Molex 09-50-8061 (USA); 09-91-0600 (UK) PINS: 08-52-0113 Connector Kit #70-841-006, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02" (0.5mm). 3. Mounting holes M1 and M2 should be grounded for EMI purposes. 4. Mounting hole M1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 Vac input, 25C unless otherwise stated. 6. Warranty: 2 year 7. Weight: 0.45 lb/0.20 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com GLT60 Series, GLT60-M Series Installation & Operating Instructions Mechanical Outline To comply with the published safety standards, the following must be observed when using this power supply: M1 M2 GND 1. Maximum ambient temperature for the power supply must not exceed 50C. R16 W2 SK201 C27 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, IEC60950-1, and CSA22.2 No. 60950-1-03 for GLT62, GLT63, GLT64, and GLT65; UL60601-1, EN60601-1, IEC60601-1, and CSA22.2 No. 60601-1-M90 for GLT62-M and GLT63-M. The safety requirements include creepage distances, clearances, and distance through insulation between primary wiring and earth or secondary (SELV) wiring. C32 IC4 R32 W3 IC1 FB1 W4 D1 T1 1 6 3 D16A D15 8. When operating with a dc input voltage range, the unit input must be protected by a dc rated fuse in the end-use installation system. R31 W6 C33 SK1 Connector PIN Designation Input Connector PIN 1 3 PIN 1 2 3 4 5 6 1 2 SK1 Output Connector 6. The disconnection from the line must be in the end system. 7. Hazardous voltages exist in the primary circuits. Disconnect the power supply before servicing. J8 C21 5. The earth ground wire must be connected only to the point marked with the earth ground symbol (on the unit). 1 SK2 3. The power supply's rated input voltage is automatically selected for GLT62, GLT63, and GLT64. Please refer to the specification sheet for the input voltage range. GLT65, GLT62-M, and GLT63-M are approved and certified for the rated voltage range of 100 V ac to 250 V ac and/or 140 V dc to 300 V dc. 4. The maximum output power of the supply must not exceed the rating indicated in the specification sheet. V Adj. Pot SK2 SK201 GLT62 (-M) GLT62 (-M) +12 V GLT63 (-M) GLT64 Neutral Line GLT63 (-M) GLT64 +15 V +12 V GLT65 GLT65 +24 V +5 V Common -12 V -15 V -5 V +12 V +Sense -Sense Note: Mounting holes M1 and M2 should be grounded for EMI purposes. Mounting hole M1 is a safety ground connection. 9. The internal fuse should only be replaced with a 3.15 A, 250 V ac, type SP0001.1009 manufactured by Schurter AG, type 2163.15 manufactured by Littelfuse, or type S501 manufactured by Cooper. 10. This power supply is not suitable for direct contact to the patient. Output Ratings Model 11. This equipment is considered Class I according to protection against electric shock. 12. This power supply is 2006/95/EC. marked following the provisions of the Low Voltage Directive, 13. For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional product information and specification sheets. GLT62 (-M) GLT63 (-M) GLT64 GLT65 Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions Output Voltage (V) +5 +12 -12 +5 +15 -15 +5 +12 -5 +5 +24 +12 Convection Cooling Max. Output Current (A) 7.0 3.0 0.7 7.0 2.8 0.7 7.0 3.0 0.7 7.0 1.5 0.7 Max. Output Power (W) 60 30 CFM Forced Air Cooling Max. Output Current (A) 8.0 3.5 1.0 8.0 3.3 1.0 8.0 3.5 1.0 8.0 2.0 1.0 Max. Output Power (W) 80 P/N: A272-199 Rev 0 5/12/09 Ref: 03361001433/03366200111/03366200551 GLT60 Series, GLT60-M Series Installation & Operating Instructions Mechanical Dimensions Typical Ventilation Setup Bottom View Top View 3.00 [76.2] 2.55 [64.8] .22 [5.6] FAN 6.69 [170.0] AIR FLOW T1 UNIT 4.55 [115.6] 1.08 [27.5] MAX Side View 7.28 [185.0] 4.33 [110.0] Side View 4.33 [110.0] FAN 5.00 [127.0] 1.57 [40.0] .22 [5.6] AIR FLOW .12 [3.0] MAX .06 [1.6] UNIT All dimensions are in inches [mm] Mounting hole diameter (4X): 0.15 [3.81 mm] Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions. GLT62, GLT63, GLT64, and GLT65 are commercial designations of model numbers LPT62, LPT63, LPT64, and LPT65 respectively. GLT62-M and GLT63-M are commercial designations of model numbers LPT62-M and LPT63-M respectively. Fan: MINEBEA 3110NL-04W-B30 Fan Input: 12 V dc NOTE: Dimensions and fan used are for reference only (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. GLT60 Series Specifications Electrical Specifications Input 85-264 Vac (wide range); 120-300 Vdc Input range 47-440 Hz Frequency Inrush current <18 A peak @ 115 Vac, <36 A peak @ 230 Vac, cold start @ 25C Input current 1.5 A max. (RMS) @ 115 Vac 70% typical at full load FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE 0878 PT3 Class B conducted Efficiency EMI filter Safety ground leakage current <0.5 mA @ 50/60 Hz, 264 Vac input Output Maximum power 60 W convection; 80 W with 30 CFM forced air Cross regulation 2% on output 1; 5% on outputs 2, 3 -5, 10% min. Adjustment range 20 ms @ 40 W load, 115 Vac nominal line Short circuit protection on all outputs. Case overload protected @ 110-145% above peak rating 5.7 to 6.7 Vdc on the main output Hold-up time Overload protection Overvoltage protection Compensates for 0.5 V lead drop minimum, will operate without remote sense connected. Reverse connection protected Remote sense GLT62, 63, 64: 0.7 A for the first output, 0.3 A for second outputs GLT65: 0.7 A for the first output, 0.1 A for second outputs Minimum Load Environmental Specifications Operating temperature 0 to 50C ambient. Derate each output 2.5% per degree from 50 to 70C, -20C startup Storage temperature Temperature coefficient Electromagnetic susceptibility -40C to 85C 0.04% per C Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Humidity Operating; non-condensing 5% to 95% Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5 Hz to 500 Hz, operational >550,000 hours at full load and 25C ambient conditions MTBF demonstrated Mating Connectors AC Input DC Outputs Remote Sense Molex 09-50-8031 (USA) 09-91-0300 (UK); PINS: 08-58-0111 Molex 09-50-8061 (USA) 09-91-0600 (UK); PINS: 08-52-0113 Molex 22-01-2025 PINS: 08-52-0113 Connector Kit #70-841-006, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02" (0.5mm). 3. Mounting holes M1 and M2 should be grounded for EMI purposes. 4. Mounting hole M1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 Vac input, 25C unless otherwise stated. 6. Warranty: 2 year 7. Weight: 0.75 lb/0.34 kg Phone: (800) 377-4384 Email: tech@solahd.com www.solahd.com Power Derating Curve 80W 30 CFM Forced Air Cooling Output Power (Watts) 60W Natural Convection Cooling 40W 40W 30W 20W 0W 0C 10C 20C 30C 40C 50C 60C TA - Ambient Temperature - C 70C GLX110-C Cover Kit Designed for the following power supplies: GL110 Series, -B versions only What's Included Overall Dimensions 7.64 in. [194.0 mm] x 4.53 in. [115.0 mm] x 2.44 in. [62.0 mm] * One cover .67 [17.0] * Four M3 x 6mm countersunk screws Assembly 4.53 [115.0] .90 [23.0] .79 [20.0] 2.34 [59.5] 2.44 [62.0] 7.64 [194.0] Figure 1: Assembly Drawing Notes * All dimensions are in inches [mm]. Figure 2: Mechanical Drawing Technical Support U.S.: (800) 377-4384 * International: (847) 268-6000 E-mail: tech@solahd.com * Web site: www.solahd.com * Ensure that the relevant safety standards (e.g. EN60950-1) are complied with, in respect to creepage and clearance distances, and distances through insulation. P/N: A272-201 Rev 0 06/22/09 Ref: LPX110-C While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. GLX120 Cover Enclosure Kit Page 1 of 2 Designed for the following power supplies: GLS120 Series Cover What's Included M3 x 6mm Countersunk Screw (4X) * One base * One cover * One insulator sheet (plastic) * Four M3 x 6mm Pan head screws (with attached spring washers) M3 x 6mm Pan Head Screw (4X) Output Terminals * Four M3 x 6mm countersunk screws Input Terminals * One M4 nut (for earth ground stud) Power Supply * One M4 spring washer (for earth ground stud) Insulator Sheet * One M4 star washer (for earth ground stud) Assembly Standoff (4X) 1. Place insulator sheet over base standoffs. M4 Nut 2. Place power supply over insulator sheet and align with base standoffs. M4 Spring Washer NOTE: Ensure the insulator sheet is correctly fitted in the base under the PBC to maintain safety creepage and clearances. 3. Secure power supply to base using the supplied M3 x 6mm Pan head screws (4). 4. Place cover over power supply and align with base countersink holes. 5. Secure cover to base using the supplied M3 x 6mm countersunk screws (4). Base M4 Star Washer Earth Ground Stud Figure 1: Assembly Drawing Notes * Ensure base is firmly connected to supply earth via the earth ground stud . * Ensure that the relevant safety standards (e.g. EN60950-1) are complied with, in respect to creepage and clearance distances, and distances through insulation. * All dimensions are in inches [mm]. P/N: A272-202 Rev 0 06/25/09 Ref: LPX120 GLX120 Cover Enclosure Kit EXTRUDED HOLE WITH M3 THREAD FORMED (2X) 0.70 [17.78] (2X) Page 2 of 2 Overall Dimensions 5.95 in. [151.1 mm] x 3.40 in. [86.4 mm] x 1.60 in. [40.6 mm] Mounting 0.70 [17.8] Two options are available: 4.55 [115.6] 1. Bottom mounting using M3 inserts. Maximum screw protrusion is 0.08 in. [2.0 mm]. 3.40 [86.4] 2. Side mounting using M3 inserts. Maximum screw protrusion is 0.24 in. [6.0 mm]. Technical Support U.S.: (800) 377-4384 * International: (847) 268-6000 E-mail: tech@solahd.com * Web site: www.solahd.com 1.60 [40.6] 5.95 [151.1] 0.70 [17.8] 0.35 [8.9] (2X) 4.55 [115.6] 5.25 [133.4] (2X) EXTRUDED HOLE WITH M3 THREAD FORMED (2X) EXTRUDED HOLE WITH M3 THREAD FORMED (4X) 2.55 [64.8] (2x) 0.43 [10.8] (2X) Figure 2: Mechanical Drawing While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. GLX140-CF Cover Top Fan Kit Designed for the following power supply: GLQ142 Overall Dimensions What's Included 3.15 [80.0] * One cover with top fan -CF option * Four M3 x 6mm countersunk screws Recommended Assembly SK3 1.50 [38.1] 1. Attach fan wires to SK5 output connector. 7.00 [177.8] 6 1 2 SK5 Figure 2: Mechanical Drawing SK2 Notes * All dimensions are in inches [mm]. 1 SK6 Figure 1: SK5 Output Connector 2. Place cover over power supply and align with base countersink holes. * Ensure that the relevant safety standards (e.g. EN60950-1) are complied with, in respect to creepage and clearance distances, and distances through insulation. Technical Support U.S.: (800) 377-4384 * International: (847) 268-6000 E-mail: tech@solahd.com * Web site: www.solahd.com 3. Secure cover to base using the supplied M3 x 6mm countersunk screws (4). P/N: A272-216 Rev 0 09/10/09 Ref: LPX140-CF While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. GLX150-C Cover Kit Designed for the following power supplies: GL150 Series Notes * All dimensions are in inches [mm]. What's Included * Ensure that the relevant safety standards (e.g. EN60950-1) are complied with, in respect to creepage and clearance distances, and distances through insulation. * One cover * Four M3 x 6mm countersunk screws Technical Support Overall Dimensions U.S.: (800) 377-4384 * International: (847) 268-6000 8.50 in. [216.0 mm] x 4.25 in. [108.0 mm] E-mail: tech@solahd.com * Web site: www.solahd.com 4.23 [107.5] 4.25 [108.0] .11 [2.7] M3 x 6mm countersunk screw (4x) R2 TYP Section Y-Y .51 [13.0] .31 [7.8] 8.03 [204.0] 8.50 [216.0] Figure 1: Mechanical Drawing P/N: A272-203 Rev 0 06/22/09 Ref: LPX150-C While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. GLX200 Cover Enclosure Kit Page 1 of 2 Designed for the following power supplies: GL200-M Series Cover What's Included M3 x 6mm Countersunk Screw (4X) * One base * One cover * One insulator sheet (plastic) * Four M3 x 6mm Pan head screws (with attached spring washers) M3 x 6mm Pan Head Screw (4X) Output Terminals * Four M3 x 6mm countersunk screws Input Terminals * One M4 nut (for earth ground stud) Power Supply * One M4 spring washer (for earth ground stud) Insulator Sheet * One M4 star washer (for earth ground stud) Assembly Standoff (4X) 1. Place insulator sheet over base standoffs. M4 Nut 2. Place power supply over insulator sheet and align with base standoffs. M4 Spring Washer NOTE: Ensure the insulator sheet is correctly fitted in the base under the PBC to maintain safety creepage and clearances. 3. Secure power supply to base using the supplied M3 x 6mm Pan head screws (4). 4. Place cover over power supply and align with base countersink holes. 5. Secure cover to base using the supplied M3 x 6mm countersunk screws (4). Base M4 Star Washer Earth Ground Stud Figure 1: Assembly Drawing Notes * Ensure base is firmly connected to supply earth via the earth ground stud . * Ensure that the relevant safety standards (e.g. EN60950-1) are complied with, in respect to creepage and clearance distances, and distances through insulation. * All dimensions are in inches [mm]. P/N: A272-206 Rev 0 12/08/09 Ref: LPX200 GLX200 Cover Enclosure Kit Page 2 of 2 Overall Dimensions (2X) M3 INSERT 5.90 in. [150.0 mm] x 3.85 in. [98.0 mm] x 1.85 in. [46.9 mm] Mounting 5.90 [150.0] Three options are available: 1. Bottom mounting using M3 inserts. Maximum screw protrusion is 0.08 in. [2.0 mm]. 2. Side mounting using 4 mm clear holes, plus two keyways. 3.85 2.56 [98.0] [65.0] 0.98 [25.0] 3. Side mounting using M3 inserts. Maximum screw protrusion is 0.24 in. [6.0 mm]. Technical Support 1.18 [30.0] 0.98 [25.0] U.S.: (800) 377-4384 * International: (847) 268-6000 E-mail: tech@solahd.com * Web site: www.solahd.com 4.33 [110.0] (2X) M3 INSERT 1.85 [46.9] 0.78 [19.9] 4.56 [115.8] 1.08 [27.6] 0.59 [15.0] R 0.17 [4.4] 0.25 [6.4] 3.54 [90.0] R 0.07 [1.8] 0.78 [19.9] 0.36 [9.3] 3.15 [80.0] 2.50 [63.3] SEE DETAIL KEYWAY DETAIL 3.14 2.55 [80.0] [64.8] 0.35 [9.0] Figure 2: Mechanical Drawing While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. GLX250-CEF Cover End Fan Kit Designed for the following power supplies: GL250 Series Overall Dimensions What's Included * One cover with end fan * Four M3 x 6mm countersunk screws Recommended Assembly 1. Remove M3 x 6mm countersunk screws (4) and original cover. 2. Attach the two fan wires to SK4 and SK7 output connectors. 2.01 1.87 [51.0] [47.5] Max Max 1.18 [30.0] 8.52 [216.4] 0.24 [6.1] Figure 2: Mechanical Drawing Notes Output Adj. SK4 SK7 + - * All dimensions are in inches [mm]. * Ensure that the relevant safety standards (e.g. EN60950-1) are complied with in respect to creepage and clearance distances, and distances through insulation. + SK5 SK3 Figure 1: Fan connection Technical Support U.S.: (800) 377-4384 * International: (847) 268-6000 E-mail: tech@solahd.com * Web site: www.solahd.com 3. Place cover over power supply and align with base countersink holes. 4. Secure cover to base using the supplied M3 x 6mm countersunk screws (4). P/N: A272-218 Rev 0 12/14/09 Ref: LPX250-CEF While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. GLX250-CF Cover Top Fan Kit Overall Dimensions Designed for the following power supplies: GL250 Series and GL350 Series What's Included 3.15 [80.0] * One cover with top fan GL250 Series: 3.00 [76.2] GLS350 Series: 3.64 [92.5] GLQ350 Series: 3.50 [88.9] * Four M3 x 6mm countersunk screws Recommended Assembly 2.17 [55.0] -CF option 3.68 [93.6] 1. Remove M3 x 6mm countersunk screws (4) and original cover. 2. Attach fan wires to SK4 or SK7 output connector for GL250 Series, SK5 or SK6 output connector for GLS350 Series and SK6 output connector for GLQ350 Series. See Figures 1-3. 3. Place cover over power supply and align with base countersink holes. 9.00 [228.6] 4. Secure cover to base using the supplied M3 x 6mm countersunk screws (4). Output Adj. SK7 Notes Output Adj. SK4 SK5 SK3 Figure 1: Fan connection for GL250 Series SK4 SK5 SK6 Figure 4: Mechanical Drawing--All Models * All dimensions are in inches [mm]. SK3 Figure 2: Fan connection for GLS350 Series * Ensure that the relevant safety standards (e.g. EN60950-1) are complied with, in respect to creepage and clearance distances, and distances through insulation. Technical Support U.S.: (800) 377-4384 * International: (847) 268-6000 E-mail: tech@solahd.com * Web site: www.solahd.com Output Adj. SK6 SK4 SK5 SK3 Figure 3: Fan connection for GLQ350 Series P/N: A272-217 Rev 0 09/10/09 Ref: LPX250-CF While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. GLX40/60 Cover Enclosure Kit Page 1 of 2 Designed for the following power supplies: GL20 Series, GL40 Series and GL60 Series What's Included Cover * One base * One cover M3 x 6mm Pan Head Screw (4X) * One insulator sheet (plastic) * Four M3 x 6mm Pan head screws (with attached washers) Output Terminals Power Supply * Two M3 x 6mm countersunk screws Input Terminals * One M4 nut (for earth ground stud) * One M4 spring washer (for earth ground stud) Insulator Sheet * One M4 star washer (for earth ground stud) Assembly 1. Place insulator sheet over base standoffs. 2. Place power supply over insulator sheet and align with base standoffs. NOTE: Ensure the insulator sheet is correctly fitted in the base under the PBC to maintain safety creepage and clearances. 3. Secure power supply to base using the supplied M3 x 6mm Pan head screws (4). 4. Place cover over power supply and align with base countersink holes. 5. Secure cover to base using the supplied M3 x 6mm countersunk screws (2). Notes * Ensure base is firmly connected to supply earth via the earth ground stud . * Ensure that the relevant safety standards (e.g. EN60950-1) are complied with, in respect to creepage and clearance distances, and distances through insulation. * All dimensions are in inches [mm]. Standoff (4X) M3 x 6mm Countersunk Screw (2X) Earth Ground Stud Base M4 Nut M4 Spring Washer M4 Star Washer Figure 1: Assembly Drawing P/N: A272-204 Rev 0 06/25/09 Ref: LPX40/60 GLX40/60 Cover Enclosure Kit Overall Dimensions 5.90 [150.0] .91 [23.0] Page 2 of 2 GL20 Series/GL40 Series: 5.90 in. [150.0 mm] x 3.86 in. [98.0 mm] x 1.50 in. [38.0 mm] .79 [20.0] GL60 Series: 5.90 in. [150.0 mm] x 3.86 in. [98.0 mm] x 1.97 in. [50.0 mm] .71 [18.0] 1.18 [30.0] 2.42 [61.5] 1.70 [43.0] 3.86 [98.0] Mounting Three options are available: 1. Bottom mounting using M3 inserts. Maximum screw protrusion is 0.08 in. [2.0 mm]. 2. Side mounting using 4 mm clear holes, plus two keyways. 3. Side mounting using M3 inserts. Maximum screw protrusion is 0.24 in. [6.0 mm]. .59 [15.0] M3 INSERT (4X) 4.33 [110.0] 3.15 [80.0] Technical Support U.S.: (800) 377-4384 * International: (847) 268-6000 E-mail: tech@solahd.com * Web site: www.solahd.com .79 [20.0] 4.80 [122.0] .35 [9.0] GL20/40: 1.50 [38.0] GL60: 1.97 [50.0] .36 [9.2] .55 [14.0] 4 mm MTG HOLE (2X) 2.76 [70.0] M3 INSERT MARKED "A" (4X) 3.54 [90.0] 1.09 [27.7] 0.25 [6.4] DIA 0.14 [3.6] DIA 0.35 [8.8] DIA KEYWAY DETAIL (2X) Figure 2: Mechanical Drawing While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. GLX50 Cover Enclosure Kit Page 1 of 2 Designed for the following power supplies: GL50 Series and GL100-M Series Cover What's Included M3 x 6mm Countersunk Screw (4X) * One base * One cover * One insulator sheet (plastic) * Four M3 x 6mm Pan head screws (with attached spring washers) M3 x 6mm Pan Head Screw (4X) Output Terminals * Four M3 x 6mm countersunk screws Input Terminals * One M4 nut (for earth ground stud) Power Supply * One M4 spring washer (for earth ground stud) Insulator Sheet * One M4 star washer (for earth ground stud) Assembly Standoff (4X) 1. Place insulator sheet over base standoffs. M4 Nut 2. Place power supply over insulator sheet and align with base standoffs. M4 Spring Washer NOTE: Ensure the insulator sheet is correctly fitted in the base under the PBC to maintain safety creepage and clearances. 3. Secure power supply to base using the supplied M3 x 6mm Pan head screws (4). 4. Place cover over power supply and align with base countersink holes. 5. Secure cover to base using the supplied M3 x 6mm countersunk screws (4). Base M4 Star Washer Earth Ground Stud Figure 1: Assembly Drawing Notes * Ensure base is firmly connected to supply earth via the earth ground stud . * Ensure that the relevant safety standards (e.g. EN60950-1) are complied with, in respect to creepage and clearance distances, and distances through insulation. * All dimensions are in inches [mm]. P/N: A272-205 Rev 0 06/08/09 Ref: LPX50 GLX50 Cover Enclosure Kit 0.98 [24.9] Page 2 of 2 Overall Dimensions 0.80 [20.4] 4.69 in. [119.0 mm] x 2.95 in. [74.8 mm] x 1.69 in. [43.0 mm] 1.46 [37.0] 1.26 [32.0] 2.95 [74.8] Mounting Three options are available: 1. Bottom mounting using M3 inserts. Maximum screw protrusion is 0.08 in. [2.0 mm]. 2. Side mounting using 4 mm clear holes, plus two keyways. 3. Side mounting using M3 inserts. Maximum screw protrusion is 0.24 in. [6.0 mm]. 4.69 [119.0] Technical Support 1.69 [43.0] 0.59 [15.0] (2X) M3 INSERT (2X) 1.00 [25.5] (2X) U.S.: (800) 377-4384 * International: (847) 268-6000 E-mail: tech@solahd.com * Web site: www.solahd.com 2.68 [68.0] (2X) 3.73 [94.7] (2X) 1.20 [30.5] (2X) 0.58 [14.7] (2X) 2.28 [58.0] (2X) 0.20 [5.0] (2X) A 2.17 [55.0] A 1.72 [43.8] 1.65 [42.0] A 2.21 [56.0] A 0.39 [9.9] (2X) M3 INSERT MARKED "A" (4X) SEE KEYWAY DETAIL 0.35 [8.8] 0.14 [3.6] 0.25 [6.4] Figure 2: Mechanical Drawing KEYWAY DETAIL (2X) While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. (c)2009 EGS Electrical Group, LLC. All rights reserved. Specifications subject to change without notice. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Sola/Hevi-Duty: GLQ112 GLS22 GLS23 GLS24 GLS42 GLS44 GLS45 GLS22-T GLS23-T GLS24-T GLS42-T GLS43-T GLS44-T GLS45-T GLS52 GLS53 GLS54 GLS62 GLS63 GLS64 GLS65 GLS114 GLQ113 GLQ114 GLQ123 GLS122 GLQ142 GLS153 GLS155 GLQ152 GLQ153 GLQ154 GLS174 GLS253-C GLS255-C GLS352-C GLS353-C GLS354-C GLS355-CEF GLQ352-C GLQ352-CEF GLS505-CF GLS508-CF GLS42-M GLS43-M GLS44-M GLS45-M GLS52-M GLS53-M GLS54-M GLS55-M GLS58-M GLS65-M GLS172-M GLS173-M GLS174-M GLS175-M GLS503-M-CF GLS508-M-CF GLS102-M GLS104-M GLS105-M GLS108-M GLS202-M GLS204-M GLS205-M GLS208-M