CUSTOMER DRAWING
.
Raychem
Devices
TITLE:
SOLDERSLEEVE DEVICE SHIELD
TERMINATION WITH PRE-INSTALLED
LEAD HIGH TEMPERATURE
Unless otherwise specified dimensions are in millimeters.
[Inches dimensions are shown in brackets] DOCUMENT NO.:
B-023-XX-55-22-9
TOLERANCES:
0.00 N/A
0.0 N/A
0 N/A
ANGLES: N/A
ROUGHNESS IN
MICRON
Tyco Electronics reserves the right to amend
this drawing at any time. Users should
evaluate the suitability of the product for their
application.
PROD. REV.:
SEE TABLE DOC. ISSUE:
B DATE: 21-May-14
PREPARED BY:
mforonda REVISED PER:
ECO-14-007657
CAGE CODE :
06090 SCALE:
None SIZE:
A SHEET:
1 of 1
©2014 Tyco Electronics Corporation All rights reserved.
If this document is printed it becomes uncontrolled. Check for the latest revision.
Product Revision Product Dimensions Cable Dimensions
Product
Name øB
min øC
min L
max øD
max øE
min J ±0.50
[J ±0.020]
B-023-00-55-22-9 A 4.30
[0.169] 5.60
[0.220] 31.00
[ 1.220] 4.30
[0.169] 3.00
[0.118] 5.00
[ 0.197]
B-023-07-55-22-9 A 3.10
[0.122] 4.50
[0.177] 29.00
[1.142] 3.10
[0.122] 2.40
[0.094] 6.00
[0.236]
MATERIALS
1. INSULATION SLEEVE: Heat-shrinkable, transparent clear, modified polytetrafluorethylene.
2. SOLDER PREFORM WITH FLUX:
SOLDER: TYPE Pb93 per ANSI/J-STD-006.
FLUX: TYPE ROM1 per ANSI/J-STD-004.
3. MELTABLE SEALING RINGS: Modified fluorinated ethylene propylene.
4. GROUND LEAD: Tyco Electronics/Raychem 55PC0813-22-9, nickel-plated copper, AWG 22, Color – white.
APPLICATION
1. These controlled soldering devices are designed for termination of a nickel-plated copper shield of a cable having
an insulation rated for at least 2 00°C continuous.
2. Temperature range: -65°C to +200°C.
3. Install using Raychem-approved convection or infrared heating tools or equivalent.
For best results, prepare the cable as shown: