OUTLET SIDE
INLET SIDE
mm
(INCH)
UNIT:
UNIT : (INCH)
mm
LABEL
105.0 0.3
105.0 0.3
120.0 0.5
120.0 0.5
(4.724 0.020)
(4.134 0.012)
(4.134 0.012)
(4.724 0.020)
5.0 0.3
38.0 0.5
(1.496 0.020)
(0.197 0.012)
5.0 0.3
(0.197 0.012)
8- 4.5 0.3
(8- 0.177 0.012)
330.0 10.0
(12.992 0.394)
10.0
(0.394)
( 5.590)
142.0
(4- 0.177)
4- 4.5
116.0
105.0
(4.134)
(4.567)
(4.134)
116.0
(4.567)
105.0
( 4.830)
122.7
(4- 0.177)
4- 4.5
116.0
105.0
(4.134)
(4.567)
(4.134)
116.0
(4.567)
105.0
2
(INCH H O)
0
Air Pressure
Air Flow
(mm H O)
40
2
0 80
0
0
6
1.3 2.6
120 160 200
3.9 5.2 6.5
(CFM)
240
(M /MIN.)
3
12
18
24
30
36
0.18
0.36
0.72
0.54
1.08
0.90
1.26
1.44
M
L
H
HH
VH
AFB1212/24XE-C
38
http://www.deltaww.com
AFB 120 x 120 x 38 MM SERIES
* Bearing Type
Ball Bearings
* Material
Impeller & Frame : Plastic (UL 94V-0)
* Lead Wires :
UL 1007 AWG #24 OR Equivalent
Red Wire Positive (+)
Black Wire Negative (-)
* Weight : 320g (11.28 oz)
â– DIMENSIONS DRAWING
â– P & Q CURVE (AT RATED VOLTAGE) â– MOUNTING PANEL CUTOUT
MODEL Rated
Voltage
Operating
Voltage
Range
Input
Current
Input
Power Speed Maximum
Air Flow
Maximum
Air Pressure Noise
PART NO. REV. FUNCTION VDC VDC Amp Watt R.P.M. m3 /min CFM mmH2O IN H2O dB-A
AFB1212LE -C -R00 / -F00 12 6.0 to 12.8 0.14 1.68 2000 2.018 71.27 4.22 0.166 32.5
AFB1224LE -C -R00 / -F00 24 14.0 to 27.6 0.11 2.64
AFB1212ME -C -R00 / -F00 12 6.0 to 12.8 0.27 3.24 2500 2.604 91.95 6.45 0.254 38.0
AFB1224ME -C -R00 / -F00 24 14.0 to 27.6 0.14 3.36
AFB1212HE -C -R00 / -F00 12 6.0 to 12.8 0.35 4.20 3000 3.092 109.17 9.22 0.363 44.0
AFB1224HE -C -R00 / -F00 24 14.0 to 27.6 0.20 4.80
AFB1212HHE -C -R00 / -F00 12 6.0 to 12.8 0.51 6.12 3500 3.704 130.80 11.48 0.452 47.0
AFB1224HHE -C -R00 / -F00 24 14.0 to 27.6 0.27 6.48
AFB1212VHE -C -R00 / -F00 12 6.0 to 12.8 0.68 8.16 4000 4.201 148.34 15.29 0.602 51.0
AFB1224VHE -C -R00 / -F00 24 14.0 to 27.6 0.36 8.64
* Function type is optional.
* The max. air ow and the speed are measured in free air ; max. air pressure is measured at zero air ow.
* Noise is measured in anechoic chamber in free air, one meter from intake side.
* All readings are typical values at rated voltage.