NEMIC-LAMBDA
JWS 120P
SPECIFICATIONS
A181-01-01A
ITEMS MODEL JWS120P-24 JWS120P-48
1
Nominal Output Voltage
V
24
48
2
Average Output Current
A
5
2.5
3
Peak Output Current
A
10
5
4
Average Output Power
W
120
120
5
Peak Output Power
W
240
240
6
Efficiency (Typ)
%
80
80
7
Input Voltage Range
-
85 ~ 265VAC (47 ~ 63Hz)
8
Input Current (100/200VAC)(Typ) (*2)
A
1.6/0.8
9
Inrush Current(Typ)
-
25A at 100VAC, 50A at 200VAC, Ta=25°C, Cold Start
10
PFHC
-
Built to meet EN61000-3-2
11
Power Factor (100/200VAC)(Typ) (*2)
-
0.98/0.92
12
Output Voltage Range
V
21.6 ~ 26.4
43.2 ~ 52.8
13
Maximum Ripple & Noise
0 ~ +60°C
mV
240
480
-10 ~ 0°C
mV
360
720
14
Maximum Line Regulation
mV
96
192
15
Maximum Load Regulation
mV
192
384
16
Temperature Coefficient
Less than 0.02%/°C
17
Over Current Protection
A
10.2 ~
5.1 ~
18
Over Voltage Protection
V
27.6 ~ 32.4
55.2 ~ 64.8
19
Hold-up Time (Typ)
-
20
Leakage Current
(*10)
-
0.75mA MAX, 0.2mA(Typ) at 100VAC / 0.44mA(Typ) at 230VAC
21
Thermal protection
(*11)
-
Built-in
22
Remote Sensing
-
Possible
23
Parallel Operation
-
-
24
Series Operation
-
Possible
25
Operating Temperature
(*12)
-
-10 ~ +60°C ( -10 ~ +50°C:100%, +60°C:60%)
26
Operating Humidity
-
30 ~ 90%RH (No dewdrop)
27
Storage Temperature
-
-30 ~ +85°C
28
Storage Humidity
-
10 ~ 95%RH (No dewdrop)
29
Cooling
-
Convection Cooling
30
Withstand Voltage
-
Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
Output - FG : 500VAC (100mA) for 1min
31
Isolation Resistance
-
More than 100Mohm at 25°C and 70%RH Output - FG... 500VDC
32
Vibration
-
At no operating, 10-55Hz (Sweep for 1min)
2G Constant, X, Y, Z 1hour each.
33
Shock (In package)
-
Less than 20G
34
Safety
(*13)
-
Built to meet UL1950, CSA950, EN60950,VDE0160.
Built to meet DENTORI.
35
Conducted Emission
-
Built to meet EN55011/EN55022-A, FCC-ClassA, VCCI-A.
36
Radiated Emission
-
Built to meet EN55011/EN55022-A, FCC-ClassA, VCCI-A.
37
Weight (Typ.)
g
900
38
Size (WxHxD)
mm
65 x 92 x 198 ( Refer to Outline Drawing )
*Read instruction manual carefully, before using the power supply unit.
=NOTES=
*1.
Operating time at peak output is less than 10sec.(Duty<=0.5)
*2.
At 100/200VAC, Ta=25°C and average output power.
*3.
For cases where conformance to various safety specifications (UL, CSA, EN) are required,
input voltage range will be 100-240VAC(50/60Hz).
*4.
Measure with EIAJ RC-9131 probe, Bandwidth of scope :100MHz.
*5.
85 - 265VAC , constant load.
*6.
No load - Average load, constant input voltage.
*7.
Constant current limit with automatic recovery.
*8.
OVP circuit will shut down output, manual reset (Line recycle).
*9.
At 100/200VAC nominal output voltage and average output current.
*10.
Measured by the each measuring method of UL, CSA, EN and DENTORI(at 60Hz).
*11.
Power Supply will recover in case of lower the temperature.
*12.
Ratings - Derating at standard mounting.
- Load (%) is percent of average output power or average output current, whichever is greater.
- As for other mountings, refer to derating curve (A181-01-02_).
*13.
As for DENTORI, built to meet at 100VAC.
A1810101_Pdf.xls
NEMIC-LAMBDA
JWS 120P
OUTPUT DERATING
A181-01-02
AVERAGE LOAD(%)
Ta(°C) MOUNTING A MOUNTING B MOUNTING C
-10 ~+40 100 100 100
45 100 80 80
50 100 60 60
55 80 - -
60 60 - -
PROHIBIT USE
OUTPUT DERATING CURVE
0
20
40
60
80
100
-10 010 20 30 40 50 60 70
Ta(°C)
AVERAGE LOAD(%)
MOUNTING A
MOUNTING B,C
MOUNTING B
MOUNTING C
MOUNTING A
(STANDARD MOUNTING )
PROHIBIT
A1810102Pdf.xls