https://www.phoenixcontact.com/us/products/2910345 Type 1 surge protection device-VAL-US-48/65/1+0-FM-2910345 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Surge protective device, single channel with remote indicator contact for 48VDC. Your advantages Plugs can be checked with CHECKMASTER Secure hold of plugs in the event of high lightning current loads and strong vibrations thanks to new latching Thermal disconnect device for each individual plug Optical, mechanical status indication for the individual arresters Pluggable Thermal disconnect device for each individual plug Mechanical coding of all slots Key Commercial Data Packing unit 1 pc GTIN GTIN 4055626444871 Weight per Piece (excluding packing) 160.000 g Custom tariff number 85363030 Country of origin Germany Technical data Dimensions Height 96.8 mm Width 17.8 mm Depth 65.5 mm 02/06/2021Page1/9 https://www.phoenixcontact.com/us/products/2910345 Type 1 surge protection device-VAL-US-48/65/1+0-FM-2910345 Technical data Dimensions Horizontal pitch 1 Div. Ambient conditions Degree of protection IP20 (only when all terminal points are used) Ambient temperature (operation) -40 C ... 80 C Ambient temperature (storage/transport) -40 C ... 80 C Altitude 2000 m (amsl (above mean sea level)) Permissible humidity (operation) 5 % ... 95 % Shock (operation) 30g (Half-sine / 11 ms / 3x X, Y, Z) Vibration (operation) 7.5g (10 ... 500 Hz / 2.5 h / X, Y, Z) General IEC test classification I / II T1 / T2 EN type T1 / T2 IEC power supply system DC Mode of protection (DC+) - (DC-) Mounting type DIN rail: 35 mm Color jet black RAL 9005 Housing material PA 6.6 PBT Degree of pollution 2 Flammability rating according to UL 94 V-0 Type DIN rail module, two-section, divisible Number of positions 1 Surge protection fault message Optical, remote indicator contact Protective circuit Nominal voltage UN 60 VDC 10% -48 VDC 10% (RRH) Maximum continuous voltage UC 100 VDC Rated load current IL 80 A Residual current IPE 0.6 mA Nominal discharge current In (8/20) s 12.5 kA Total discharge current Itotal (10/350)s 12.5 kA Short-circuit current rating ISCCR 5 kA Voltage protection level Up 0.4 kV Residual voltage Ures 0.4 kV (at In) 02/06/2021Page2/9 https://www.phoenixcontact.com/us/products/2910345 Type 1 surge protection device-VAL-US-48/65/1+0-FM-2910345 Technical data Protective circuit 0.35 kV (at 10 kA) 0.3 kV (at 5 kA) 0.25 kV (at 3kA) TOV behavior at UT 130 VDC (5s / withstand mode) Response time tA 25 ns Max. backup fuse with V-type through wiring 80 A (gG) Max. backup fuse with branch wiring 160 A (gG) Indicator/remote signaling Switching function Changeover contact Operating voltage 5 VAC ... 250 VAC 30 VDC Operating current 5 mA AC ... 1.5 A AC 1 ADC (30VDC) Connection method Screw connection Screw thread M2 Tightening torque 0.25 Nm Stripping length 7 mm Conductor cross section flexible 0.14 mm ... 1.5 mm Conductor cross section solid 0.14 mm ... 1.5 mm Conductor cross section AWG 28 ... 16 Connection data Connection method Screw connection Screw thread M5 Tightening torque 4.5 Nm (1.5mm ... 16mm) 4.5 Nm (25mm...35mm) Stripping length 16 mm Conductor cross section flexible 1.5 mm ... 25 mm Conductor cross section solid 1.5 mm ... 35 mm Conductor cross section AWG 15 ... 2 UL specifications SPD Type 1 Maximum continuous operating voltage MCOV 100 VDC Nominal voltage 48 VDC Mode of protection (DC+) - (DC-) Power distribution system DC Voltage protection rating VPR 400 V 02/06/2021Page3/9 https://www.phoenixcontact.com/us/products/2910345 Type 1 surge protection device-VAL-US-48/65/1+0-FM-2910345 Technical data UL specifications Nominal discharge current In 20 kA Maximum Surge Current per Phase 65 kA Short-circuit current rating (SCCR) 5 kA UL indicator/remote signaling Operating voltage 125 VAC Operating current 1 A AC Tightening torque 2 lbf-in. ... 4 lbf-in. Conductor cross section AWG 30 ... 14 UL connection data Conductor cross section AWG 10 ... 2 Tightening torque 30 lbf-in. Standards and Regulations Standards/regulations IEC61643-11 2011 EN61643-11 2012 Environmental Product Compliance REACh SVHC Lead 7439-92-1 Drawings Dimensional drawing Circuit diagram 96,8 77,5 12 17,6 14 11 FM 44 89,8 Classifications eCl@ss eCl@ss 10.0.1 27130805 eCl@ss 11.0 27130805 eCl@ss 6.0 27130800 eCl@ss 7.0 27130805 eCl@ss 8.0 27130805 02/06/2021Page4/9 https://www.phoenixcontact.com/us/products/2910345 Type 1 surge protection device-VAL-US-48/65/1+0-FM-2910345 Classifications eCl@ss eCl@ss 9.0 27130805 ETIM ETIM 5.0 EC000941 ETIM 6.0 EC000941 ETIM 7.0 EC000941 Approvals Approvals Approvals UL Listed / cUL Listed / cULus Listed Ex Approvals Approval details UL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 330181 cUL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 330181 cULus Listed Accessories Accessories Bridge 02/06/2021Page5/9 https://www.phoenixcontact.com/us/products/2910345 Type 1 surge protection device-VAL-US-48/65/1+0-FM-2910345 Accessories Wiring bridge-MPB 18/1-10/1.0.0-2830443 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 10 pitches with contact sequence 1-0-0 Wiring bridge-MPB 18/4-12-2809296 Wiring bridge for modules with connecting pitch 17.5 mm, 4-phase, 12-pos. Wiring bridge-MPB 18/4- 8-2809283 Wiring bridge for modules with connecting pitch 17.5 mm, 4-phase, 8-pos. Wiring bridge-MPB 18/3- 6-2809241 Wiring bridge for modules with connecting pitch 17.5 mm, 3-phase, 6-pos. Wiring bridge-MPB 18/1-57-2809238 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 57-pos. 02/06/2021Page6/9 https://www.phoenixcontact.com/us/products/2910345 Type 1 surge protection device-VAL-US-48/65/1+0-FM-2910345 Accessories Wiring bridge-MPB 18/1-12-2748593 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 12-pos. Wiring bridge-MPB 18/1- 9-2748580 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 9-pos. Wiring bridge-MPB 18/1- 8-2748577 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 8-pos. Wiring bridge-MPB 18/1- 6-2748564 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 6-pos. Wiring bridge-MPB 18/1- 4-2809225 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 4-pos. 02/06/2021Page7/9 https://www.phoenixcontact.com/us/products/2910345 Type 1 surge protection device-VAL-US-48/65/1+0-FM-2910345 Accessories Wiring bridge-MPB 18/1- 3-2809212 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 3-pos. Wiring bridge-MPB 18/1- 2-2809209 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 2-pos. Device marking Zack marker strip-ZBN 18:UNBEDRUCKT-2809128 Zack marker strip, Strip, white, unlabeled, can be labeled with: CMS-P1-PLOTTER, PLOTMARK, mounting type: snap into tall marker groove, for terminal block width: 18 mm, lettering field size: 18 x 5 mm, Number of individual labels: 5 Feed-through terminal block Feed-through terminal block-DK-BIC-35-2749880 Feed-through terminal block for VAL and FLT applications Labeled device marker 02/06/2021Page8/9 https://www.phoenixcontact.com/us/products/2910345 Type 1 surge protection device-VAL-US-48/65/1+0-FM-2910345 Accessories Marker for terminal blocks-ZBN 18,LGS:ERDE-2749589 Marker for terminal blocks, Strip, white, labeled, horizontal: Grounding symbol, mounting type: snap into tall marker groove, for terminal block width: 18 mm, lettering field size: 18 x 5 mm, Number of individual labels: 5 Marker for terminal blocks-ZBN 18,LGS:L1-N,ERDE-2749576 Marker for terminal blocks, Strip, white, labeled, horizontal: L1, L2, L3, N, GND, mounting type: snap into tall marker groove, for terminal block width: 18 mm, lettering field size: 18 x 5 mm, Number of individual labels: 5 Marker pen Marker pen-B-STIFT-1051993 Marker pen, for manual labeling of unprinted Zack strips, smear-proof and waterproof, line thickness 0.5 mm Spare parts Type 1 surge protection plug-VAL-US-48/65-P-2910328 UL Recognized type 1 SPD and IEC type 2 surge protection plug with a varistor and thermal disconnect for use with VALUS base elements, mechanical and visual fault warning Phoenix Contact 2021 (c) - all rights reserved http://www.phoenixcontact.com 02/06/2021Page9/9