Ultra-low Power Real Time Clock Module with I2C Bus AB-RTCMC-32.768kHz-IBO5-S3 ESD Sensitive Moisture Sensitivity Level: MSL=1 Pb FEATURES: RoHS/RoHS II compliant 3.7 x 2.5 x 0.9 mm APPLICATIONS: * Smart cards * Wireless sensors and tags * Medical/Healthcare electronics * Sports and fitness electronics * Smart Utility meters * Data loggers * Appliances * Tracking systems * Home security systems * Industrial and Consumer electronics * Communications equipment * Ultra-Low current consumption: XTAL Mode 60nA typ. @3.0V RC Mode 17nA typ. @3.0V RC Autocalibrated Mode 22nA typ. @3.0V * RTC module with built-in crystal oscillating at 32.768 kHz * Operating voltage: 1.5 - 3.6V * Operating temperature range: -40 to +85C * Factory calibrated Time accuracy 2.0ppm typ. @ 25C * Automatic Battery Switchover * Trickle Charger, Power Management & Power Switch Function * Programmable CLKOUT frequencies * I2C Bus Interface (fast mode 400kHz) * Time keeping mode down to 1.5 V * Programmable Alarm, Timer and INT * Up to 512 Bytes of general purpose RAM * Small and compact package size: 3.7 x 2.5 x 0.9 mm. RoHS-compliant and 100% lead free STANDARD SPECIFICATIONS: Absolute Maximum Ratings Parameters Min. Typ. Max. Units Power Supply Voltage (VDD) -0.3 3.8 V Backup Supply voltage (VBACKUP) -0.3 3.8 V Notes Input Voltage (VI) VDD Power state -0.3 VDD + 0.3 V VBACKUP Power State -0.3 VBACUUP + 0.3 V Output Voltage (VO) VDD Power state -0.3 VDD + 0.3 V VBACKUP Power State -0.3 VBACUUP + 0.3 V Input Current (II) -10 10 mA Output Current (IO) -20 20 mA PSW Output Continuous Current (IOPC) 50 mA PSW Output Pulsed Current (IOPP) 150 mA CDM 500 V Charged Device Model HBM 4000 V Human Body Model 100 mA ESD Voltage (VESD) Latch-up Current (ILU) Operating Temperature Range (TOP) -40 +85 C Storage Temperature (TSTG) -55 +125 Lead Temperature (TSLD) +300 C C Reflow Soldering Temperature (TREF) +260 C LLC 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: www.abracon.com 1 second pulse Stored as bare product Hand soldering for 10s Reflow profile per JEDEC J-STD-020D ABRACON IS REVISED: 01.08.2019 ISO9001-2015 CERTIFIED Ultra-low Power Real Time Clock Module with I2C Bus AB-RTCMC-32.768kHz-IBO5-S3 Pb RoHS/RoHS II compliant 3.7 x 2.5 x 0.9 mm Power Supply and Switchover Parameters TA = -40 to +85C, Typ. values at +25C Parameters System Power Voltage (VDD) VDD I2C Interface Voltage (VDDIO) VDD Start-up Voltage (VDDST) (1) VDD Reset Voltage (VDDRST) VDD Rising Switch-over Threshold Voltage (VDDSWR) VDD Falling Switch-over Threshold Voltage (VDDSWF) VDD Switch-over Threshold Hysteresis (VDDSWH) (2) VDD Falling Slew Rate to Switch to VBACKUP State (VDDFS) (4) Backup Voltage (VBACKUP) Backup Switchover Voltage Range (VBACKSW) (5) Falling Backup POR Voltage (VBACKRST) (7) VBACK Margin above VDD (VBMRG) (3) VBACK Supply Series Resistance (RBACKESR) (6) Type Power State Static VDD Power Static VDD Power Rising Falling POR->VDD Power VDD Power -> POR I2C operation Min. Typ. Max. Units 1.5 3.6 V 1.5 3.6 V 1.6 V VBACKUP < VBACKUP, MIN or no VBACKUP 1.3 1.5 V 1.6 1.7 V Rising VBACKUP Power ->VDD Power VBACKUP VBACKRST Falling VDD Power -> VBACKUP Power VBACKUP VBACKSW, MIN Hyst. VDD Power <-> VBACKUP Power Falling VDD Power -> VBACKUP Power VDD < VDDSW, MAX 0.7 Static VBACKUP Power Clocks operating and RAM and registers retained 1.4 3.6 V Static VDD Power -> VBACKUP Power 1.6 3.6 V Falling VBACKUP Power -> POR 1.4 V Static VBACKUP Power 200 Static VBACKUP Power 1.0 LLC CERTIFIED Test Conditions Clocks operating and RAM and registers retained 1.2 VDD < VDDSWF 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: www.abracon.com 1.5 V 70 mV 1.4 V 1.1 mV 1.5 k ABRACON IS REVISED: 01.08.2019 ISO9001-2015 CERTIFIED Ultra-low Power Real Time Clock Module with I2C Bus AB-RTCMC-32.768kHz-IBO5-S3 Pb RoHS/RoHS II compliant 3.7 x 2.5 x 0.9 mm (1) VDD must be above VDDST to exit the POR state, independent of the VBACKUP voltage. (2) Difference between VDDSWR and VDDSWF. (3) VBACKUP must be higher than VDD by at least this voltage to insure the AB-RTCMC-32.768kHz-IBO5-S3 remains in the VBACKUP Power state. (4) Maximum VDD falling slew rate to guarantee correct switchover to VBACKUP Power state. There is no VDD falling slew rate requirement if switching to the VBACKUP power source is not required. (5) VBACKUP voltage to guarantee correct transition to VBACKUP Power state when VDD falls. (6) Total series resistance of the power source attached to the VBACKUP pin. The optimal value is 1.5 k, which may require an external resistor. VBACKUP power source ESR (Equivalent Series Resistance) + external resistor value = 1.5 k. (7) VBACKRST is also the static voltage required on VBACKUP for register data retention. Operating Parameters TA = -40 to +85C, Typ. values at +25C Parameters Test Conditions VDD Min. Typ. Max. Positive-going Input Threshold Voltage (VT+) 3.0V 1.5 2.0 1.8V 1.1 1.25 Negative-going Input Threshold Voltage (VT-) 3.0V 0.8 0.9 1.8V 0.5 0.6 Input Leakage Current (IILEAK) Input Capacitance (CI) PSW Output Resistance to VDD (RDSON) 3.0V Output Leakage Current (IOLEAK) V V 0.02 80 3 nA pF 1.7V 1.7 5.8 1.8V 1.6 5.4 3.0V 1.1 3.8 3.6V 1.05 3.7 1.7V - 3.6V 0.02 80 PSW enabled Units nA Oscillator Parameters TA = -40 to +85C unless otherwise indicated. VDD = 1.7 to 3.6V, Typ. values at +25C and 3.0V Parameters Crystal Frequency (FXT) XT Oscillator Failure Detection Frequency (FOF) Calibrated RC Oscillator Frequency (FRCC) (1) Uncalibrated RC Oscillator Frequency (FRCU) Uncalibrated RC Oscillator Cycle-to-Cycle Jitter, |Median| (JRCCC) RC Oscillator Cycle-to-Cycle Jitter, MIN, MAX (JRCCC) XT Mode Digital Calibration Accuracy (AXT) (1) Test Conditions Factory calibrated at +25C, VDD = 2.8V Calibration disabled (OFFSETR=0) - 128Hz level Calibration disabled (OFFSETR=0) - 128Hz level Calibration disabled (OFFSETR=0) - 1Hz level 128Hz level at +25C Min. 89 Typ. Max. 32.768 kHz 8 kHz 64 Hz 122 200 2000 1 128Hz level -10 to +70C -3.5 3.5 128Hz level -40 to +85C Calibrated at an initial temperature and voltage. Factory calibrated at +25C, VDD = 3.0V -10 10 -2 +2 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: www.abracon.com Hz ppm 500 -1 LLC Units % ppm ABRACON IS REVISED: 01.08.2019 ISO9001-2015 CERTIFIED Ultra-low Power Real Time Clock Module with I2C Bus AB-RTCMC-32.768kHz-IBO5-S3 Pb 3.7 x 2.5 x 0.9 mm RoHS/RoHS II compliant (Continued) TA = -40 to +85C unless otherwise indicated. VDD = 1.7 to 3.6V, Typ. values at +25C and 3.0V Parameters Autocalibration Mode Timing Accuracy, 512 second period, TA = -10 to +60C (AAC) (1) Test Conditions Min. Typ. 24 hour run time 35 1 week run time 20 1 month run time 10 1 year run time 3 Autocalibration Mode Operating Temperature (TAC) (2) -10 Max. Units ppm +60 C (1) Timing accuracy is specified at 25C after digital calibration of the internal RC oscillator and digital calibration of the 32.768 kHz crystal. The 32.768 kHz tuning fork crystal has a negative temperature coefficient with a parabolic frequency deviation, which can result in a change of up to 150 ppm across the entire operating temperature range of -40C to 85C in XT mode. Autocalibration mode timing accuracy is specified relative to XT mode timing accuracy from -10C to 60C. (2) Outside of this temperature range, the RC oscillator frequency change due to temperature may be outside of the allowable RC digital calibration range (+/-12%) for autocalibration mode. When this happens, an autocalibration failure will occur and the ACF interrupt flag is set. The AB-RTCMC-32.768kHz-IBO5-S3 should be switched to use the XT oscillator as its clock source when this occurs. Please see the AUTOCALIBRATION FAILURE section in the application manual for more details. XT Frequency Characteristics TA = -40 to +85C unless otherwise indicated. VDD = 1.7 to 3.6V, Typ. values at +25C and 3.0V, fOSC = 32.768kHz Parameters Frequency Accuracy (F/F) Frequency vs. Temperature Characteristics (F/F0) Turnover Temperature (T0) Test Conditions TA = +25C; Calibration disabled (OFFSETX=0) TOPR = -40 to +85C Oscillator Start-up Time CLKOUT Duty Cycle Typ. VDD = 1.7V - 3.6V FCLKOUT = 32.768kHz; TA = +25C Units ppm -0.035ppm/C2 * (TOPR-T0)2 10% ppm +25 TA = +25C TA= -40 to +85C Max. 100 (1) +20 Aging First Year Oscillator Start-up Voltage Min. +30 C 3 ppm 1.6 V 1.0 50 60 s 70 % (1) The XT mode digital calibration accuracy is +/-2 ppm, see OSCILLATOR PARAMETERS. LLC CER 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: www.abracon.com ABRACON IS REVISED: 01.08.2019 ISO9001-2015 CERTIFIED Ultra-low Power Real Time Clock Module with I2C Bus AB-RTCMC-32.768kHz-IBO5-S3 Pb 3.7 x 2.5 x 0.9 mm RoHS/RoHS II compliant XT Frequency vs. Temperature Characteristics VDD Supply Current TA = -40 to +85C. VBACKUP = 0 to 3.6V, Typ. values at +25C, VDD power state Parameters Test Conditions VDD VDD Supply Current during I2C burst Read/Write (IVDD:I2C) 400kHz bus speed, 2.2k pullup resistors on SCL/SDA (1) VDD Supply Current in XT Oscillator Mode (IVDD:XT) Time keeping mode with XT oscillator running (2) VDD Supply Current in RC Oscillator Mode (IVDD:RC) Average VDD Supply Current in Autocalibrated RC Oscillator Mode (IVDD:ACAL) Additional VDD Supply Current with CLK/ INT at 32.768kHz (IVDD:CK32) Additional VDD Supply Current with CLK/ INT at 64Hz (IVDD:CK64) ABRACON IS ISO 9001 / QS 9000 R Typ. Max. 3.0V 6 10 1.8V 1.5 3 3.0V 60 330 1.8V 27 290 3.0V 17 220 1.8V 14 170 3.0V 22 235 1.8V 18 190 3.0V 0.71 (3) 1.8V 0.34 All time keeping mode, 64Hz 3.0V 0.6 1.8V 0.3 Time keeping mode with only the RC oscillator running (XT oscillator is off) (2) Time keeping mode with only the RC oscillator running and Autocalibration enabled. ACP=512 seconds (2) Time keeping mode with XT oscillator running, 32.768kHz square wave on CLK/ INT square wave on CLK/ INT LLC (3) Min. 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: www.abracon.com Units A nA nA nA A nA ABRACON IS REVISED: 01.08.2019 ISO9001-2015 CERTIFIED Ultra-low Power Real Time Clock Module with I2C Bus AB-RTCMC-32.768kHz-IBO5-S3 Pb 3.7 x 2.5 x 0.9 mm RoHS/RoHS II compliant (1) Excluding external peripherals and pull-up resistor current. All other inputs (besides SDA and SCL) are at 0V or VDD. Test conditions: Continuous burst read/write, 55h data pattern, 25 s between each data byte, 20 pF load on each bus pin. (2) All inputs and outputs are at 0V or VDD. (3) All inputs and outputs except CLK / INT are at 0V or VDD. 15 pF load on CLK / INT , pull-up resistor current not included. VBACKUP Supply Current TA = -40 to +85C. Typ. values at +25C, Max. values at +85C. VBACKUP power state Parameters VBACKUP Supply Current in XT Oscillator Mode (IVBACK:XT) VBACKUP Supply Current in RC Oscillator Mode (IVBACK:RC) Average VBACKUP Supply Current in Autocalibrated RC Oscillator Mode (IVBACK:ACAL) VBACKUP Supply Current in VDD powered mode (IVBACK:VDD) Test Conditions VDD Time keeping mode with XT oscillator running (1)