http://www.phoenixcon.com May 6, 2011
Rated actuating voltage range with reference to
UC
0.4 ... 1.1
Rated actuating current IC12.5 mA
Switching threshold "0" signal, voltage 48 V AC
Switching threshold "1" signal voltage 96 V AC
Protective circuit Surge protection Varistor
Status display Yellow LED
Indication Red LED
Output data, load relay
Output name AC output
Nominal output voltage 500 V AC
Nominal output voltage range 48 V AC ... 575 V AC
Periodic peak reverse voltage 1200 V
Load current max. 16 A (see derating curve)
Leakage current 6 mA
Residual voltage < 1.5 V
Surge current 300 A (t = 10 ms)
Max. load value 580 A2s
Type of protection RCV circuit
Surge voltage protection > 575 V AC
General data
Width 147.5 mm
Height 99 mm
Depth 114.5 mm
Test voltage input/output 5 kVrms
Ambient temperature (operation) -25 °C ... 70 °C
Ambient temperature (storage/transport) -25 °C ... 70 °C
Mounting position Vertical (horizontal DIN rail)
Assembly instructions Can be aligned with spacing = 40 mm
Operating mode 100% operating factor
Degree of protection IP20
Name Standards/regulations
Standards/regulations DIN EN 50178
EN 60947