G6C G6C
3
Double-winding Latching Type
Rated
voltage
3 VDC 5 VDC 6 VDC 12 VDC 24 VDC
Set coil
Rated current
93.5 mA 56.0 mA 46.7 mA 23.3 mA
1
1.7 mA
Coil resistance
32.1
Ω
89.3
Ω
129
Ω
514
Ω
2,056
Ω
Coil inductance
Armature OFF 0.03 0.07 0.10 0.37 1.56
(H) (ref. value)
Armature ON 0.02 0.06 0.08 0.32 1.18
Reset coil
Rated current
93.5 mA 56.0 mA 46.7 mA 23.3 mA
1
1.7 mA
Coil resistance
32.1
Ω
89.3
Ω
129
Ω
514
Ω
2,056
Ω
Coil inductance
Armature OFF 0.03 0.08 0.12 0.47 1.46
(H) (ref. value)
Armature ON 0.02 0.07 0.10 0.38 1.13
Must set voltage
70% max. of rated voltage
Must reset voltage
70% min. of rated voltage
Max. voltage
130% of rated voltage
Power consumption
Set coil:
Approx. 280 mW
Reset coil:
Approx. 280 mW
Note: 1.
The rated current and coil resistance are measured at a coil temperature of 23
°
C with a tolerance of
±10%.
2.
Operating characteristics are measured at a coil temperature of 23
°C.
3.
The minimum pulse width of the set and reset voltage is 20 ms.
Contact Ratings
Item SPST-NO SPST-NO+SPST-NC
Load Resistive
load
(cosφ
= 1)
Inductive load
(cosφ
= 0.4; L/R = 7 ms)
Resistive load
(cosφ
= 1)
Inductive load
(cosφ
= 0.4; L/R = 7 ms)
Rated load
10 A at 250 V
AC;
10A at 30 VDC
5 A at 250 V
AC;
5 A at 30 VDC
8 A at 250 V
AC;
8A at 30 VDC
3.5 A at 250 V
AC;
3.5 A at 30 VDC
Contact material
AgCdO
Rated carry current
10 A
8 A
Max. switching voltage
380 V
AC, 125 VDC (the case of latching 250 V
AC, 125 VDC)
Max. switching current
10 A
8 A
Max. switching capacity
2,500 V
A, 300 W
1,250 V
A, 220 W
2,000 V
A, 240 W
875 V
A, 170 W
Min. permissible load
10 mA at 5 VDC
Characteristics
Contact
resistance
30 m
Ω
max.
Operate (set) time
10 ms max. (mean value: approx. 5 ms)
Release (reset) time
10 ms max. (mean value: approx. 2 ms; latching types: mean value: approx. 5 ms)
Bounce time
Operate:
5 ms max.
Release:
5 ms max.
Min. set/reset signal width
Latching type: 20 ms (at 23
°C)
Max. switching frequency
Mechanical:
18,000 operations/hr
Electrical:
1,800 operations/hr (under rated load)
Insulation resistance
1,000 M
Ω
min. (at 500 VDC, at 250 VDC between set coil and reset coil)
Dielectric strength
2,000 V
AC, 50/60 Hz for 1 min between coil and contacts
2,000 V
AC, 50/60 Hz for 1 min between contacts of dif
ferent polarity
1,000 V
AC, 50/60 Hz for 1 min between contacts of same polarity
250 V
AC, 50/60 Hz for 1 min between set and reset coils
Impulse withstand voltage
6.000 V
, 1.2 x 50
µ
s (between coil and contacts) (latching types: 4500 V
, 1.2
50
µs)
V
ibration resistance
Destruction:
10 to 55 Hz, 1.5-mm double amplitude
Malfunction:
10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Destruction:
1,000 m/s
2
(approx. 100G)
Malfunction:
100 m/s
2
(approx. 10G)
Ambient temperature
Operating: –25°
C to 70
°
C (with no icing)
Storage: –25°
C to 70
°
C (with no icing)
Ambient humidity
Operating: 35% to 85%
Life expectancy
Mechanical:
50,000,000 operations min. (at 18,000 operations/hr)
Electrical:
100,000 operations min. (at 1,800 operations/hr)
Weight
Approx. 5.6 g