SERIES GRF311
GENERAL ELECTRICAL SPECIFICATIONS (@ 25 ºC unless otherwise noted)
Contact Arrangement 1 Form C (SPDT)
Rated Duty Continuous
Contact Resistance 0.15 Ω max. initial (measured 1/8" from the header)
Contact Load Rating Resistive: 1Amp/28Vdc
Low level: 10 to 50 μA, 10 to 50 mV
Contact Life Ratings 10,000,000 cycles (typical) at low level
Coil Operating Power 350 mW typical @ nominal rated voltage
Operate Time 4.0 mS max.
Release Time 3.0 mS max.
Intercontact Capacitance 0.4 pF typical
Insulation Resistance 1,000 MΩ min. between mutually isolated terminals
Dielectric Strength 350 Vrms (60 Hz) @ atmospheric pressure
DETAILED ELECTRICAL SPECIFICATIONS (@25°C)
BASE PART NUMBERS GRF311-5 GRF311-12 GRF311-26
Coil Voltage, Nominal (Vdc) 5.0 12.0 26.5
Coil Resistance (Ohms ±20%) 63 500 2000
Pick-up Voltage (Vdc max.) 3.6 9.0 18.0
GENERAL NOTES
1. Relays will exhibit no contact chatter in excess of 10 μsec or transfer in excess of 1 μsec.
2. Relays may be subjected to 260 ºC peak solder reflow temperature, 1 minute, 3 passes.
3. Butt-lead ends are coplanar within .003” (0.08 mm).
4. Application notes available for PCB mounting information.
OUTLINE DIMENSIONS
.031
[0.79]
REF
.035
[0.89]
REF
Ø.200
[Ø5.08] 45°±3°
TYP
.315
[8] MAX
Ø.370
[9.4]
MAX RF GROUND SHIELD
(SEE NOTE 3)
32
14
SCHEMATIC - TERMINAL VIEW
5
PIN NUMBERS ARE FOR
REFERENCE ONLY;
NOT MARKED ON RELAY
© 2009 Teledyne Relays SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE GRF311 Page 3