Industrial Power Supplies TCL Series, 24 to 240 Watt Features For industrial, office and residential UL 60950 UL 508C UL 60950-1 applications Ultracompact plastic housing Connection by spring clamp terminals or detachable screw terminal block Reliable snap-on mounting on DIN-rails Adaptor for wall mounting Universal input 85-264 VAC, 50/60 Hz Models with 5, 12, 24 & 48 VDC output Output voltage adjustable Power OK signal Low ripple and noise Overload and short-circuit protection Parallel operation possible Worldwide safety approvals Redundancy module 3-year product warranty The TRACO POWER TCL series is a family of DIN-rail power supplies with an excellent price/performance ratio. With tightly regulated output voltage and high immunity against electrical disturbances on the mains they provide a reliable power source for sensitive loads in industrial process controls, machine tools and other equipment exposed to a difficult industrial environment. Compact size, light weight, easy snap-on mounting on DIN-rails and the choice of two connection terminal versions are other features of these power supplies. The TCL series complies with all major safety standards for Europe (EN60950-1, EN50178), North America (UL/cUL 60950, UL 508 listed) or elsewhere in the world (CB-Report). Models Order Code Input Voltage Output Power *Output Voltage Output Current Ranges max. nom. max. 20 W 5 VDC 4.0 A 12 VDC 2.0 A 24 VDC 1.0 A 12 VDC 4.0 A 24 VDC 2.5 A Detachable screw 48 VDC 1.25 A terminal blocks 12 VDC 8.0 A 24 VDC 5.0 A 240 W 24 VDC 10.0 A 24 W 24 VDC 1.0 A 12 VDC 4.0 A 24 VDC 2.5 A 48 VDC 1.25 A Spring clamp 12 VDC 8.0 A terminals 24 VDC 5.0 A TCL 024-105 TCL 024-112 TCL 024-124 24 W TCL 060-124 85 - 264 VAC Universal Input 50/60 Hz TCL 060-148 85 - 375 VDC TCL 060-112 TCL 120-112 120 W TCL 120-124 TCL 240-124 85-132/187-264 VAC TCL 024-124C TCL 060-112C TCL 060-148C 85 - 264 VAC Universal Input 50/60 Hz TCL 120-112C 85 - 375 VDC TCL 060-124C TCL 120-124C 60 W 60 W 120 W Connection * adjustable www.tracopower.com Page 1 of 6 Industrial Power Supplies TCL Series 24 to 240 Watt Input Specifications Input voltage range 85-264 VAC/85-375 VDC TCL 240 model: 85-132/187-264 VAC autoselect (no DC input) Output derating - at operation between 85...93 VAC/85...130 VDC 15% for TCL 060 & TCL 120 20% for TCL 024-112 & TCL 024-124 & TCL 240 30% for TCL 024-105 Input frequency 47-63 Hz Harmonic limits EN 61000-3-2, Class A Input current at full load (typ.) (115 VAC / 230 VAC) Recommended circuit breaker TCL 024 models: TCL 060 models: TCL 120 models: TCL 240 model: 0.35 A / 0.2 A 1.2 A / 0.6 A 2.0 A / 1.0 A 3.3 A / 1.7 A TCL 240 model: 10 A (characteristic C or slow blow fuse) all other models: 5 A (characteristic C or slow blow fuse) Output Specifications Output voltage adjustable range (potentiometer on frontpanel) 5.1 VDC model: 12 VDC models: 24 VDC models: 48 VDC models: 5.0 - 5.25 VDC 12 - 15 VDC (12 - 16 VDC for TCL 024-112) 24 - 28 VDC 48 - 56 VDC Output regulation (10 to 90% load variation) 2.5 % (1 % for TCL 60-112) Ripple and noise (20MHz bandwidth) <50 mV pk-pk Electronic short circuit protection current limitation at 120 % typ. (constant current, automatic recovery TCL 24 models: foldback, automatic recovery) Parallel operation output current characteristic suitable for parallel operation of max. 5 units (not for TCL 240-124) Overvoltage protection, trigger point 5.1 VDC model: <6.5 VDC 12/24 VDC models: <40 VDC 48 VDC models: <60 VDC Hold-up time (115 VAC / 230 VAC) min. 15 ms / min. 125 ms TCL 240 model: min. 15 ms / min. 40 ms Power OK signal (TCL 60, 120 & 240 models only) trigger point 12 VDC models: >11V 24 VDC models: >22V 48 VDC models: >44V output signal (reference to - Vout) 11.0 V 1.0 V / 60 mA max. 22.0 V 2.0 V / 30 mA max. 44.0 V 4.0 V / 15 mA max. General Specifications Temperature ranges - Operating -10C to +70C max. - Storage (non operating) -25C to +85C Temperature derating - at 187...264 VAC or 265...375 VDC operation 1.7 %/K above +50C - at 93...132 VAC or 130...187 VDC operation 1.1 %/K above +40C - at 85...130 VDC operation 1.3 %/K above +30C Humidity (non condensing) 95 % rel. H max. Temperature coefficient 0.02 %/K Switching frequency 55 - 180 kHz depending on load (frequency modulation) Efficiency 88 % typ. Isolation voltage www.tracopower.com - I/O isolation voltage (60 s) 3000 VAC Page 2 of 6 Industrial Power Supplies TCL Series 24 to 240 Watt General Specifications Reliability, calculated MTBF at +25C (according to IEC-1709) TCL 024 TCL 060 TCL 120 TCL 240 models: models: models: models: Safety standards - Information technology equipment - Industrial control equipment - Electronic equipment for power installation - Electrical equipment for machines - Safety transformers for SMPS >2.68 Mio h >2.70 Mio h >1.62 Mio h >1.38 Mio h IEC 60950-1, EN 60950-1 (output SELV), UL Std. 60950-1 (2nd Edition) +Am1:2011, CAN/CSA-C22.2 No. 60950-1-07 +Am1:2011 UL 508 EN 50178 EN 60204 EN 61558-2-16 Safety approvals - CB test certificate IEC 60950-1 - UL approval UL 508 listed, CSA C22.2 No. 14 File e210002 www.ul.com -> certifications - UL approval UL 60950, File e181381 (except TCL 240) www.ul.com -> certifications - CSA certification UL 60950-1, CSA 60950-1-03 - Certification documents www.tracopower.com/overview/tcl Environmental compliance - Reach www.tracopower.com/info/reach-declaration.pdf - RoHS RoHS directive 2011/65/EU Electromagnetic compatibility (EMC), emissions EN 61000-6-3 Electromagnetic compatibility (EMC), immunity EN 61000-6-2 Safety class degree of protection class 1 Case protection IP 20 (IEC 60529) Enclosure material plastic 94V-0 rated Mounting DIN-rails as per EN 50022-35x15/7.5 (snap-on with self-locking spring) Adapter for wall-/chassis mounting (included) Options output characteristic optimized for battery charging available on request Installation instructions www.tracopower.com/overview/tcl All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. www.tracopower.com Page 3 of 6 Industrial Power Supplies TCL Series 24 to 240 Watt TCL-REM240 Redundancy Module This module enables redundant operation of any two TCL models by decoupling the 2 power supplies. It can also be used to separate sensitive loads from the main power source. Order Code Nominal Input Voltage Input Voltage Range Max Power per Input Output Voltage Output Current max. TCL-REM240 5...48 VDC 5...60 VDC 200 W Vin - 0.9 VDC 8A Specifications Operating temperature -10C to +70C max. (14F ... +158F) derating above +40C (104F): 1.5 %/K Electromagnetic compatibility in correspondence to connected units (no internal switching device) Dimensions same as model TCL 024 (see page 4) Connection detachable screw terminal block Installation instructions www.tracopower.com/overview/tcl Case Dimensions TCL 024 and TCL-REM240 models 100.0 (3.94) OUTPUT 1 2 75.0 (2.95) DC-ON LED Output voltage adjust 1 2 3 INPUT Input 1 AC Ground 2 Neutral 3 Live 2.2 (0.09) Output 1 +Vout 2 -Vout Weight: 140 g (4.9 oz) 27 (1.06) www.tracopower.com Dimensions in [mm], ( ) = Inch Tolerances: 0.5 mm (0.02) Page 4 of 6 Industrial Power Supplies TCL Series 24 to 240 Watt Case Dimensions TCL 60 models 100.0 (3.94) OUTPUT 1 2 3 4 5 75.0 (2.95) DC-ON LED Output voltage adjust 1 2 3 INPUT Input 1 AC Ground 2 Neutral 3 Live 3.2 (0.13) Output 1 +Vout 2 +Vout 3 -Vout 4 -Vout 5 Power OK Weight: 265 g (9.4 oz) 45 (1.77) TCL 120 models 100.0 (3.94) OUTPUT 1 2 3 4 5 Output voltage adjust 1 75.0 (2.95) DC-ON LED 2 3 INPUT 3.2 (0.13) DIN rail mounting hooks 20mm (0.79) wide 85 (3.35) Output 1 +Vout 2 +Vout 3 -Vout 4 -Vout 5 Power OK Input 1 AC Ground 2 Neutral 3 Live Weight: 440 g (15.5 oz) Dimensions in [mm], ( ) = Inch Tolerances: 0.5 mm (0.02) www.tracopower.com Page 5 of 6 Industrial Power Supplies TCL Series 24 to 240 Watt Case Dimensions TCL 240 model 125 (4.92) OUTPUT 1 2 3 4 5 DC-ON LED 110 (4.33) Output voltage adjust 1 2 3 INPUT Output 1 +Vout 2 +Vout 3 -Vout 4 -Vout 5 Power OK Input 1 AC Ground 2 Neutral 3 Live Weight: 950 g (33.5 oz) 85 (3.35) Wall Mounting Bracket Instead on a DIN-rail, the modules can be also mounted on a chassis or wall with help of a mounting bracket which is supplied as standard with each power supply Dimensions in [mm], ( ) = Inch Tolerances: 0.5 mm (0.02) Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com www.tracopower.com Rev. September 6, 2018 Page 6 of 6 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: TRACO Power: TCL 024-124 TCL 120-124 TCL 060-124 TCL 024-112 TCL 060-112 TCL 060-124C TCL 024-105 TCL 120-112 TCL 024-124C TCL 060-148 TCL 060-112C TCL 120-124C TCL 060-148C TCL 120-112C TCL 240-124