RESISTANCE PER POLE VALUES
from Line to Load Terminals
(Values Based on Series Trip Circuit Breaker)
F-Series Circuit Breaker - General Specications
Mechanical
Physical
Environmental
Electrical
Maximum Voltage
Current Rating
Auxiliary Switch Rating
Insulation Resistance
Dielectric Strength
Resistance, Impedance
Endurance
Trip Free
Trip Indication
Number of Poles
Internal Circuit Cong.
Available Accessories
Weight
Standard Colors
Shock
Vibration
Moisture Resistance
Salt Spray
Thermal Shock
Operating Temperature
Designed and tested in accordance with requirements of
specication MIL-PRF-55629 & MIL-STD-202 as follows:
125VDC, 277 VAC
Standard current coils: 100, 125,
150, 175, 225, 250 amps. 300, 350,
400, 500, 600, 700 amps available as
parallel pole construction.
SPDT; 10.1 Amps @ 250VAC, 1.0
Amps @ 65VDC, 0.5 Amps @ 80VDC
0.1 Amps @ 125VAC (with gold
contacts).
Minimum: 100 Megohms at 500 VDC
1960 VAC, 50/60 Hz for one minute
between all electrically isolated
terminals, except 2500 VAC for one
minute between alarm/aux. switch
and main terminals with contacts in
open and closed position. F-Series
circuit breakers comply with the
8mm spacing & 3750VAC 50/60
Hz dielectric requirements from
hazardous voltage to operator
accessible surfaces, between
adjacent poles and from main circuits
to auxilary circuits per Publications EN
60950 and VDE 0805.
Values from Line to Load Terminal -
based on Series Trip Circuit Breaker.
4000 ON-OFF operations with rated
Current & Voltage & 4000 operations
with no load (8000 operations
total) @ 5 per minute. Parallel Pole
construction: 1000 operations with
rated Current and Voltage @ 5 per
minute.
All F-Series Circuit Breakers will trip on
overload, even when the actuator is
forcibly held in the ON position.
The operating actuator moves
positively to the OFF position when
an overload causes the circuit breaker
to trip.
1 - 3 Poles Note: Ratings over 250
Amps only available with parallel pole.
Series (with or without auxiliary
switch), Switch Only (with or without
auxiliary switch).
Factory installed: DC Current Metering
Shunt (25 mV @lr)
Varies depending on construction.
Consult factory.
Housing - Black; Actuator- Black
or White with contrasting ON-OFF
legend.
Withstands 100 Gs, 6ms, sawtooth while
carrying rated current per Method 213,
Test Condition “I”. Instantaneous and
ultra-short curves tested @ 90% of rated
current.
Withstands 0.060” excursion from 10-
55 Hz, and 10 Gs 55-500 Hz, at rated
current per Method 204C, Test Condition
A. Instantaneous and ultrashort curves
tested at 90% of rated current.
Method 106D; ten 24-hour cycles @ +
25°C to +65°C, 80-98% RH.56 days @
+85°C, 85% RH.
Method 101, Condition A (90-95% RH @
5% NaCl Solution, 96 hrs).
Method 107D, Condition A (Five cycles
@ -55°C to +25°C to +85°C to +25°C).
-40°C to +85°C.
*Manufacturer reserves the right to change product specification without prior notice.