2007-03-30 Silicon NPN Phototransistor NPN-Silizium-Fototransistor Version 1.0 SFH 313 FA Features: Besondere Merkmale: * Spectral range of sensitivity: 740 ... 1080 nm * * * * * Spektraler Bereich der Fotoempfindlichkeit: 740 ... 1080 nm * Gehause: 5mm Radial (T 1 3/4), Harz * Besonderheit: 5 mm-Plastikbauform * Hohe Fotoempfindlichkeit * Speziell geeignet fur Anwendungen im Bereich von 740 nm bis 1080 nm Package: 5mm Radial (T 1 3/4), Epoxy Special: 5 mm plastic package High photosensitivity Especially suitable for applications from 740 nm to 1080 nm Applications * * * * Anwendungen Computer-controlled flashes Photointerrupters Industrial electronics For control and drive circuits * * * * Computer-Blitzlichtgerate Lichtschranken Industrieelektronik Messen / Steuern / Regeln Ordering Information Bestellinformation Type: Photocurrent Ordering Code Typ: Fotostrom Bestellnummer = 950 nm, Ee = 0.5 mW/cm2, VCE = 5 V IPCE [A] SFH 313 FA 2500 Q62702P1674 SFH 313 FA-2/3 4000 ... 12500 Q62702P3597 SFH 313 FA-3/4 6300 Q62702P5196 2007-03-30 1 Version 1.0 SFH 313 FA Maximum Ratings (TA = 25 C) Grenzwerte Parameter Symbol Values Unit Bezeichnung Symbol Werte Einheit Operating and storage temperature range Betriebs- und Lagertemperatur Top; Tstg -40 ... 100 C Collector-emitter voltage Kollektor-Emitter-Spannung VCE 70 V Collector current Kollektorstrom IC 50 mA Collector surge current Kollektorspitzenstrom ( < 10 s) ICS 100 mA Emitter-collector voltage Emitter-Kollektor-Spannung VEC 7 Total power dissipation Verlustleistung Ptot 200 mW Thermal resistance Warmewiderstand RthJA 375 K/W V Characteristics (TA = 25 C, = 950 nm) Kennwerte Parameter Symbol Values Werte Unit Bezeichnung Symbol Wavelength of max. sensitivity Wellenlange der max. Fotoempfindlichkeit S max 870 nm Spectral range of sensitivity Spektraler Bereich der Fotoempfindlichkeit 10% 740 ... 1080 nm Radiant sensitive area Bestrahlungsempfindliche Flache A Dimensions of chip area Abmessung der Chipflache LxW 2007-03-30 2 Einheit 0.55 mm2 1 x 1 mm x mm Version 1.0 SFH 313 FA Parameter Symbol Values Unit Bezeichnung Symbol Werte Einheit Half angle Halbwinkel Capacitance Kapazitat (VCE = 5 V, f = 1 MHz, E = 0) CCE 10 pF Dark current Dunkelstrom (VCE = 20 V, E = 0) ICE0 3 ( 200) nA 2007-03-30 3 10 Version 1.0 SFH 313 FA Grouping (TA = 25 C, = 950 nm) Gruppierung Group Min Photocurrent Max Photocurrent Rise and fall time Collector-emitter saturation voltage Gruppe Min Fotostrom Max Fotostrom Anstiegs- und Abfallzeit Kollektor-Emitter Sattigungsspann ung Ee = 0.5 mW/cm2, VCE = 5 V Ee = 0.5 mW/cm2, VCE = 5 V IC = 1 mA, VCC = 5 V, RL = 1 k IC = I PCEmin x 0.3, Ee = 0.5 mW/cm2 IPCE, min [A] IPCE, max [A] tr, tf [s] VCEsat [mV] -1 2500 5000 8 150 -2 4000 8000 10 150 -3 6300 12500 12 150 -4 10000 14 150 Note.: IPCEmin is the min. photocurrent of the specified group. Anm.: IPCEmin ist der minimale Fotostrom der jeweiligen Gruppe. 2007-03-30 4 Version 1.0 SFH 313 FA Photocurrent Fotostrom IPCE = f(Ee), VCE = 5 V Relative Spectral Sensitivity Relative spektrale Empfindlichkeit SFH 313 FA Srel = f() OHF02337 10 2 mA OHF02331 100 PCE S rel % 80 10 1 60 10 0 40 10 -1 20 0 400 600 800 10 -2 -3 10 1000 nm 1200 10 -2 mW/cm 2 Ee 10 0 Photocurrent Fotostrom IPCE / IPCE(25C)= f(TA), VCE = 5 V Photocurrent Fotostrom IPCE = f(VCE), Ee = Parameter OHF02336 10 2 mA PCE PCE OHF01524 1.6 PCE 25 1.4 mW 1 2 cm 1.2 0.5 mW cm 2 1.0 10 1 0.25 0.8 mW cm 2 0.6 0.1 mW cm 2 0.4 0.2 10 0 2007-03-30 0 10 20 30 40 50 0 -25 V 70 VCE 5 0 25 50 75 C 100 TA Version 1.0 SFH 313 FA Dark Current Dunkelstrom ICEO = f(T A), E = 0 Dark Current Dunkelstrom ICEO = f(VCE), E = 0 OHF02341 10 2 nA CEO CEO 10 1 10 2 10 0 10 1 10 -1 10 0 10 -1 0 10 -2 0 10 20 30 40 50 V 70 V CE 20 40 60 80 C 100 TA Total Power Dissipation Verlustleistung Ptot = f(T A) Collector-Emitter Capacitance Kollektor-Emitter Kapazitat CCE = f(VCE), f = 1 MHz, E = 0 CCE OHF02342 10 3 nA OHF00349 18 pF 16 Ptot OHF02340 250 mW 200 14 12 150 10 8 100 6 4 50 2 0 -2 10 2007-03-30 10 -1 10 0 10 1 0 V 10 2 V CE 6 0 20 40 60 80 C 100 TA Version 1.0 SFH 313 FA Directional Characteristics Winkeldiagramm Srel = f() 40 30 20 10 0 OHF02330 1.0 50 0.8 60 0.6 70 0.4 80 0.2 0 90 100 1.0 0.8 0.6 0.4 0 20 40 60 80 Package Outline Mazeichnung 9.0 (0.354) 1.8 (0.071) 1.2 (0.047) 7.5 (0.295) 29 (1.142) 27 (1.063) 5.9 (0.232) 5.5 (0.217) 5.7 (0.224) 0.6 (0.024) 5.1 (0.201) Chip position 0.4 (0.016) Cathode (Diode) Collector (Transistor) GEXY6260 Dimensions in mm (inch). / Mae in mm (inch). 2007-03-30 o4.8 (0.189) Area not flat 0.8 (0.031) 0.5 (0.020) 2.54 (0.100) spacing 0.6 (0.024) 0.4 (0.016) 7.8 (0.307) o5.1 (0.201) 8.2 (0.323) 7 100 120 Version 1.0 SFH 313 FA TTW Soldering Wellenloten (TTW) IEC-61760-1 TTW / IEC-61760-1 TTW OHLY0598 300 C T 10 s 250 Normalkurve standard curve 235 C ... 260 C Grenzkurven limit curves 2. Welle 2. wave 200 1. Welle 1. wave 150 ca 200 K/s 2 K/s 5 K/s 100 C ... 130 C 100 2 K/s 50 Zwangskuhlung forced cooling 0 0 50 100 150 200 t 2007-03-30 8 s 250 Version 1.0 SFH 313 FA Disclaimer Disclaimer Attention please! The information describes the type of component and shall not be considered as assured characteristics. Terms of delivery and rights to change design reserved. Due to technical requirements components may contain dangerous substances. For information on the types in question please contact our Sales Organization. If printed or downloaded, please find the latest version in the Internet. Packing Please use the recycling operators known to you. We can also help you - get in touch with your nearest sales office. By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs incurred. Components used in life-support devices or systems must be expressly authorized for such purpose! Critical components* may only be used in life-support devices** or systems with the express written approval of OSRAM OS. Bitte beachten! Lieferbedingungen und Anderungen im Design vorbehalten. Aufgrund technischer Anforderungen konnen die Bauteile Gefahrstoffe enthalten. Fur weitere Informationen zu gewunschten Bauteilen, wenden Sie sich bitte an unseren Vertrieb. Falls Sie dieses Datenblatt ausgedruckt oder heruntergeladen haben, finden Sie die aktuellste Version im Internet. Verpackung Benutzen Sie bitte die Ihnen bekannten Recyclingwege. Wenn diese nicht bekannt sein sollten, wenden Sie sich bitte an das nachstgelegene Vertriebsburo. Wir nehmen das Verpackungsmaterial zuruck, falls dies vereinbart wurde und das Material sortiert ist. Sie tragen die Transportkosten. Fur Verpackungsmaterial, das unsortiert an uns zuruckgeschickt wird oder das wir nicht annehmen mussen, stellen wir Ihnen die anfallenden Kosten in Rechnung. Bauteile, die in lebenserhaltenden Apparaten und Systemen eingesetzt werden, mussen fur diese Zwecke ausdrucklich zugelassen sein! Kritische Bauteile* durfen in lebenserhaltenden Apparaten und Systemen** nur dann eingesetzt werden, wenn ein schriftliches Einverstandnis von OSRAM OS vorliegt. *) A critical component is a component used in a life-support device or system whose failure can reasonably be expected to cause the failure of that life-support device or system, or to affect its safety or the effectiveness of that device or system. **) Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fail, it is reasonable to assume that the health and the life of the user may be endangered. *) Ein kritisches Bauteil ist ein Bauteil, das in lebenserhaltenden Apparaten oder Systemen eingesetzt wird und dessen Defekt voraussichtlich zu einer Fehlfunktion dieses lebenserhaltenden Apparates oder Systems fuhren wird oder die Sicherheit oder Effektivitat dieses Apparates oder Systems beeintrachtigt. **) Lebenserhaltende Apparate oder Systeme sind fur (a) die Implantierung in den menschlichen Korper oder (b) fur die Lebenserhaltung bestimmt. Falls Sie versagen, kann davon ausgegangen werden, dass die Gesundheit und das Leben des Patienten in Gefahr ist. 2007-03-30 9 Version 1.0 SFH 313 FA Published by OSRAM Opto Semiconductors GmbH Leibnizstrae 4, D-93055 Regensburg www.osram-os.com (c) All Rights Reserved. 2007-03-30 10