Power Supplies
3
Contact Technical Services at (800) 377-4384 with any questions.
Visit our website at www.solahd.com.
148
GL Series: Single & Multi Output Switchers
The new GL series provides a broad range of AC/DC
power supply solutions that covers power ratings from 25
watts to 500 watts for use in various industrial and medical
applications requiring standard footprint size and very high
reliability.
These low-prole AC/DC switchers offer universal input
voltage with no switches or jumpers, ideal for higher volume
worldwide applications.
All models feature:
• Industry standard footprints
• Universal input
• Full power to 50°C
• High demonstrated MTBF
• Automatic overvoltage protection
• Overload protection
• Built-in EMI Filtering
• Extensive safety approvals
• Derated operation to 70°C
±2% regulation on main output
• 250 VA and higher VA size enclosed
• Two year limited warranty
Many models feature:
• EN61000-3-2 Compliance
• Supervisory outputs (5 V/12 V)
• Wide-adjustable oating 4th output
• Single wire current share
• Medical approvals
• Remote Sense
• Adjustable main output
• Power Fail and DC Good signals
• Wide-adjustable on single output models
Certifications and Compliances
UL 60950
E137632
CUL/CSA-C22.2
No. 234-M90
Recognized Component, ITE
- UL 60950-1
Certied, ITE
- CSA C22.2 CSA 60950-1
- IEC60950-1
Cover and Bracket Options
• Cover options can be ordered separately. They are
designed to simplify mechanical integration of the
power supplies into systems and add an extra measure
of electrical safety for service personnel.
• Bracket kits can be ordered separately for GL110 series
only. It is needed when the cover option is used.
Cover and Bracket Options
Catalog Number Description
GLX40 Enclosure kit for the GL20 and GL40
GLX50 Enclosure kit for the GL50 and GL100-M
GLX60 Enclosure kit for the GL60
GLX110-B Bracket kit for the GL110
GLX110-C Cover kit for the GL110
GLX120 Enclosure kit for the GLS120 and GLQ120
GLX140-C Cover kit for the GLQ140
GLX140-CF Cover with top fan kit for the GLQ140
GLX150-C Cover kit for the GL150
GLX17Q-C Cover kit for the quad output GL170
GLX17S-C Cover kit for the single output GL170
GLX200 Enclosure kit for the GL200-M
GLX250-CEF Cover end fan kit for the GL250
GLX250-CF Cover with top fan kit for the GL250/350
Mating Connectors
Catalog Number Description
70-841-008 GLX40, GLX50 and GLX60 Mating Connector Kit
70-841-007 GLS110 Mating Connector Kit
70-841-008 GLQ110 Mating Connector Kit
70-841-020 GLS120 Mating Connector Kit
70-841-012 GLQ123 Mating Connector Kit
70-841-017 GLQ142 Mating Connector Kit
70-841-009 GLS150 Mating Connector Kit
70-841-010 GLQ150 Mating Connector Kit
70-841-015 GLQ170 Mating Connector Kit
70-841-016 GLS170 Mating Connector Kit
70-841-005 GLX250 Mating Connector Kit
70-841-011 GLS350 Mating Connector Kit
70-841-024 GLS500 Mating Connector Kit
Mating Connectors
• Can be ordered separately for units with Molex
connection
• Kits include mating housing and pins for input and output
connection
E137632
Power Supplies 3
Contact Technical Services at (800) 377-4384 with any questions.
Visit our website at www.solahd.com.
149
Notes:
1. Proper circuit protection required when operating with a DC input voltage. 2. Regulation and ripple may deviate from the spec at -20°C start up.
GL20, GL40 GL50 GL60, GL110 GLQ120,
GLS120 GL140 GL150 GL170 GL250,
GL350 GL500
Input
Input
Voltage 1
85 - 264 Vac;
120 - 300 Vdc
90 - 264 Vac
127 - 300 Vdc
85 - 264 Vac
120 - 300 Vdc
85 - 132 Vac
or 170 - 264 Vac
auto-selected.
220 - 300 Vdc
85 - 264 Vac; 120 - 300 Vdc 85 - 264 Vac
Frequency 47-63 Hz , 400± 40 Hz 47-63 Hz
Inrush
Current
GL20: <15A peak
@ 115 Vac; <30A
peak @ 230 Vac,
cold start @ 25°C.
GL40: <18A peak
@ 115 Vac; <36A
peak @ 230 Vac,
cold start @ 25°C
<60A peak
@ 230 Vac,
cold start @ 25°C
<18A peak
@ 115 Vac,
<36 A peak
@ 230 Vac,
cold start @
25°C
GLQ120:
38 A max., cold
start @ 25°C
GLS120:
40A max., cold
start @ 25°C
38 A max, cold start @ 25°C
GL250:
20 A max.,
cold start
@ 25°C.
GL350:
38 A max.,
cold start
@ 25°C.
50 A max.,
cold start
@ 25°C
Efficiency 70% typical
at full load
80% - 85%
typical
at full load
70% typical
at full load
GLQ120: 65%
typical at full
load. GLS120:
80% typical at
full load
75% typical at full load
85% typical
at full load,
nominal line
EMI/RFI FCC Class B ; CISPR 22 Class B ; EN55022 Class B
Safety
Ground
Leakage
Current
Non-Medical:
<0.5 mA
Medical: < 75 µA
@ 50/60 Hz,
264 Vac input
Non-medical:
<0.5mA
Medical: 275 µA
@ 50/60 Hz;
264 Vac input for
Class I; <0.25mA
@ 50/60 Hz;
264 Vac input for
Class II (for single
output only)
Non-Medical:
<0.5 mA
Medical:
< 75µA
@ 50/60 Hz;
264 Vac input
GLQ120:
<1 mA
@ 50/60 Hz,
264 Vac input.
GLS120:
0.5mA
@ 50/60 Hz,
264 Vac input
1.0 mA
@ 50/60 Hz,
264 Vac input
<0.5 mA
@ 50/60 Hz,
264 Vac input
Non-Medical:
0.1 mA
Medical:
< 250 µA
1.0 mA
@ 50/60 Hz,
264 Vac input
<0.5 mA
@ 50/60 Hz,
264 Vac input
Non-Medical:
<0.5 mA
Medical:
<0.3mA
@ 50/60 Hz,
264 Vac input
Output
Power Refer to the selection table
Adjustment
Range on
Main Output
-5, +10%
minimum
±20% minimum for
single output only
models
GL60: -5,
+10% minimum
GL110: ±5%
on main, 5-25 V
on 4th output
±5% minimum
3.3 - 5.5V on
main; -12 -
15V on 3rd
output 3.3 -
25 V on 4th
output
±5% minimum
on main, 5-25 V
on 4th output
2:1 wide
ratio
minimum
2:1 wide ratio ±5%
Hold-up
Time
20 ms @ full load,
115 Vac nominal line
10/20 ms 115/230
Vac Input line 20 ms @ full load, 115 Vac nominal line
Overload Short circuit protection on all outputs. Primary overload protection
Overvoltage
Protection
5 V output; 5.7 to
6.7 Vdc. Other
outputs 10% to
25% above
nominal output
30-50% above
nominal output
5 V output; 5.7
- 6.7 Vdc. Other
outputs 10%
to 25% above
nominal output
3.3 V and 5 V
output: 20% to
35%
above nominal
output
Tracks out-
puts 1, 3 & 4;
10 to 35%
5 V output: 5.7
to 6.7 Vdc.
Other out-
puts10% to 25%
above nominal
output
10% to 40%
above
nominal
output
5 V output: 5.7
to 6.7 Vdc.
Other outputs
10% to 25%
above
nominal output
20-35%
above
nominal
output
Remote Sense Compensates for 0.5 V lead drop minimum; Will operate without remote sense connected, Reverse connection protected
General
Temperature 2Storage: -40°C to +85°C; Operating: 0° to 50°C ambient. Derate each output 2.5% per degree from 50° to 70°C, -20°C start up.
Electro-
magnetic
Susceptibility
Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 or EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3
Humidity Operating; non-condensing up to 95% RH
Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5Hz to 500 Hz
(2 G peak 8 Hz to 500 Hz for GL500)
MTBF >550,000 hours demonstrated at full load and 25°C ambient conditions
Safety Non-Medical: EN60950, UL UL60950 E132002, CSA CSA 22.2-234 Level 3 LR53982C, CB Certicate and report; CE Mark (LVD)
Medical: UL 2601; CSA 22.2 No. 601.1; EN 60601-1
Specifications
Power Supplies
3
Contact Technical Services at (800) 377-4384 with any questions.
Visit our website at www.solahd.com.
150
Catalog
Number Output 1 Output 2 Output 3 Output 4 Case 3Pin
Assignments 3
Mating
Connectors 3
GL20
[40 W] 25 W
GLS22 5 V @ 5 A [8 A] 6- - -
1
1A
1B
GLS23 12 V @ 2.1 A [3.3 A] 6- - -
GLS24 15 V @ 1.7 A [2.7] 6- - -
GLT22 5 V @ 3 A [4 A] 712 V @ 1.5 A [2 A] 7-12 V @ 0.5 A [0.7 A] -
2A
GLT23 5 V @ 4 A [5 A] 7 12 V @ 0.5 A [0.7 A] -12 V @ 0.5 A [0.7 A] -
GLT24 5 V @ 3 A [4 A] 712 V @ 1.5 A [2 A] 7 -5 V @ 0.5 A [0.7 A] -
GLT25 5 V @ 3 A [4 A] 715 V @ 1.5 A [2 A] 7 -15 V @ 0.5 A [0.7 A] -
GL40
[55 W] 40 W 1
[40 W] 25 W 2
GLS42 4 5 V @ 8 A [11 A] 6- - -
1
3A
1B
GLS43 4 12 V @ 3.3 A [4.5] 6- - -
GLS44 415 V @ 2.6 A [3.6 A] 6- - -
GLS45 424 V @ 1.6 A [2.3 A] 6- - -
GLT42 45 V @ 4 A [5 A] 712 V @ 2 A [2.5 A] 7-12 V @ 0.5 A [0.7 A] -
4A
GLT43 5 V @ 6 A [8 A] 7 12 V @ 0.5 A [0.7 A] -12 V @ 0.5 A [0.7 A] -
GLT44 5 V @ 4 A [5 A] 712 V @ 2 A [2.5 A] 7-5 V @ 0.5 A [0.7 A] -
GLT45 4 5 V @ 4 A [5 A] 715 V @ 2 A [2.5 A] 7-15 V @ 0.5 A [0.7 A] -
GLT46 5 V @ 4 A [5 A] 724 V @ 1 A [1.5 A] 7 +12 V @ 0.5 A [0.7 A] -
GL50
[50 W] 50 W
GLT52 45 V @ 8 A 712 V @ 3 A 7-12 V @ 0.5 A -
2 5A 2B
GLT53 45 V @ 8 A 7 15 V @ 2.4 A 7 -15 V @ 0.5 A -
GLT54 45 V @ 8 A 7 24 V @ 1.5 A 712 V @ 0.5 A -
GL50
[60 W] 60 W
GLS52 45 V @ 11 A - - -
3 6A 2B
GLS53-I 512 V @ 5A - - -
GLS53 412 V @ 5 A 6- - -
GLS54 415 V @ 4 A 6- - -
GLS55 424 V @ 2.5 A 6- - -
GLS58 4 48 V @ 1.25 A 6- - -
GL60
[80 W] 60 W 1
[60 W] 40 W 2
GLS62 5 V @12 A [16 A] 6- - -
4
7A 3B
GLS63 412 V @ 5 A [6.7 A] 6- - -
GLS64 415 V @ 4 A [5.3 A] 6- - -
GLS65 424 V @ 2.5 A [3.3 A] 6- - -
GLT62 45 V @ 7 A [8 A] 712 V @ 3 A [3.5 A] 7-12 V @ 0.7 A [1 A] -
8A 4B
GLT63 45 V @ 7 A [8 A] 7 15 V @ 2.8 A [3.3 A] 7-15 V @ 0.7 A [1 A] -
GLT64 5 V @ 7 A [8 A] 712 V @ 3 A [3.5 A] 7 -5 V @ 0.7 A [1 A] -
GLT65 5 V @ 7 A [8 A] 724 V @ 1.5 A [2 A] 7+12 V @ 0.7 A [1 A] -
GL110
[110 W] 80 W 1
[90 W] 70 W 2
GLS114 15 V @ 5.3 A [7.3 A] 6- - -
5
9A 5B
GLS115 24 V @ 3.3 A [4.6 A] 6- - -
GLQ112 5 V @ 9 A [11 A] 812 V @ 4.5 A [5 A} -12 V @ 0.7 A [1 A] ±5-25 V @ 2.5 A [3 A] 6
10A 6B
GLQ113 5 V @ 9 A [11 A] 815 V @4.5 A [5 A] -15 V @ 0.7 A [1 A] ±5-25 V @ 2.5 A [3 A] 6
GLQ114 5 V @ 9 A [11 A] 8 12 V @ 4.5 A [5 A] -12 V @ 0.7 A [1 A] 24 V @ 3.5 A [4.5 A] 8
Selection Table
Notes:
[ ] Rating with 30 CFM of air
1. Power rating when no cover option is used
2. Power rating when the cover/enclosure option is used
3. Refer to GL Series Dimensions and the sections that follow
4. Add “-M” sufx for the medical model numbers
5. Industrial version - Operating temperature -40°C to 80°C
6. Floating output
7. Approximate minimum loading: 10%
8. Approximate minimum loading: 23%
Power Supplies 3
Contact Technical Services at (800) 377-4384 with any questions.
Visit our website at www.solahd.com.
151
Catalog
Number Output 1 Output 2 Output 3 Output 4 Case 5Pin
Assignments 5
Mating
Connectors 5
GLQ120
[120 W] 70 W GLQ123 3.3 V @ 14 A [25 A] 5 V @ 12.5 A [24 A] 9+12 V @ 1 A [2 A] -12 V @ 0.5 A [1 A] 6 11A 7B
GLS120
[130 W] 80 W
GLS122 5 V @ 16 A [26 A] 8- - -
7 12A 8B
GLS123 12 V @ 6.6 A [10.8 A] 8- - -
GL140
[145 W] 80 W GLQ142 5 V @ 12 A [25 A]
(3.3 V - 5 V) 12 V @ 5 A [6 A] -12 V @ 1 A [1.5 A]
(-12 V - 15 V)
±3.3-25 V @ 1.5 A
[4.5 A] 8 10 8 13A 9B
GL150
[150 W] 110 W 1
[130 W] 75 W 2
GLS152 5 V @ 22 A [30 A] 8- - -
9 14A 10B
GLS153 12 V @ 9.1 A [12.5 A] 8
(12 V- 15 V) - - -
GLS155 24 V @ 4.5 A [6.2 A] 8
(24 V - 28 V) - - -
GLQ152 5 V @ 15 A [22 A] 912 V @ 2.6 A [8 A] 11 -12 V @ 2 A [2.5 A] 11 ±5-25 V @ 2.5 A [3 A] 8
10 15A 11B
GLQ153 5 V @ 15 A [22 A] 9 15 V @ 4.8 A [6.4 A] 11 -15 V @ 1.6 A [2 A] 11 ±5-25 V @ 2.5 A [3 A] 8
GLQ154 5 V @ 15 A [22 A] 912 V @ 6 A [8 A] 11 -12 V @ 2 A [2.5 A] 11 24 V @ 3.5 A [4.5 A] 9
GL170
[175 W] 110 W 1
[130 W] 75 W 2
GLS172 65 V @ 22 A [35 A] 8
(2.5 V - 6 V) - - -
11 16A 12B
GLS173 612 V @ 9.1 A [15 A] 8
(6 V- 12 V) - - -
GLS174 615 V @ 7.3 A [12 A] 8
(12 V - 24 V) - - -
GLS175 624 V @ 4.5 A [7.5] 8
(24 V - 54 V) - - -
GLQ172 5 V @ 15 A [30 A]
(3.3 V - 5.5 V) 12 V @ 6 A [8 A] 10 -12 V @ 0.2 A [3 A]
(-12 V - 15 V) ±3.3-25 V @ 2 A [5 A] 812 17A 13B
GL250
[250 W] 3 4
GLS253-C 12 V (6-12 V) @ [21 A] - - -
13 18A
14B
GLS255-C 24 V (24-48) @ [10.4 A] 8- - -
GLQ252-C 5 V @ [35 A] 11 12 V @ [10 A] -12 V @ [6 A] ±5-25 V @ [6 A] 8
14 19A
GLQ253-C 5 V @ [35 A] 11 15 V @ [10 A] -15 V @ [6A] ±5-25 V @ [6 A] 8
GL350
[350 W] 3 4
GLS352-C 5 V (3-6 V) @ [70 A] - - -
15 20A 15B
GLS353-C 12 V (6-12 V)
@ [29.2 A] 8- - -
GLS354-C 15 V (12-24 V)
@ [23.3 A] 8- - -
GLS355-C 24 V (24-48 V)
@ [14.6 A] 8- - -
GLS355-CEF 24 V (24-48 V)
@ [14.6 A] 8- - -
GLQ352-C 5 V @ [50 A] 11 12 V @ [12 A] -12 V @ [6 A] ±3.3-24 V @ [6 A] 8
16 21A 16B
GLQ352-CEF 5 V @ [50 A] 11 12 V @ [12 A] -12 V @ [6 A] ±3.3-24 V @ [6 A] 8
GL500
[500 W] 200 W
GLS503-CF 712 V @ 16.6 A [41.7 A] - - -
17 22A 17B
GLS505-CF 724 V @ 8.3 A [20.8 A] - - -
GLS508-CF 748 V @ 4.2 A [10.4 A] - - -
Selection Table (continued)
6. Add “-M” sufx for the medical models numbers.
7. Insert (-M) as in GLS 50x-M-CF for medical model numbers
8. Floating output
9. Approximate minimum loading: 16%
10. Approximate minimum loading: 30%
11. Approximate minimum loading: 10%
Notes:
[ ] Rating with 30 CFM of air
1. Power rating when no cover option is used
2. Power rating when the cover/enclosure option is used
3. Optional fan cover, See Table 1
4. Optional end fan cover, See Table 1
5. Refer to GL Series Dimensions and the sections that follow
Power Supplies
3
Contact Technical Services at (800) 377-4384 with any questions.
Visit our website at www.solahd.com.
152
GL Series Dimensions
Notes:
1. Specications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02” (±0.5 mm)
3. Mounting holes M1 and M2 should be grounded for EMI purposes.
4. Mounting hole M1 is safety ground connection.
5. Specications are for convection rating at factory settings at 115 Vac input, 25°C unless otherwise stated.
Case 1
(Weight: 0.5 lbs/0.23 kg approx.)
Case 2
(Weight: 0.45 lbs/0.20 kg approx.)
Case 3
(Weight: 0.41 lbs/0.18 kg approx.)
Case 4
(Weight: 0.75 lbs/0.34 kg approx.)
Power Supplies 3
Contact Technical Services at (800) 377-4384 with any questions.
Visit our website at www.solahd.com.
153
GL Series Dimensions (continued)
Notes:
1. Specications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02” .
3. Specications are for convection rating at factory settings unless otherwise stated.
4. Mounting holes M1 and M2 should be grounded for EMI purposes.
5. Mounting hole M1 is safety ground connection.
6. L Bracket mounting (6-32) maximum insertion depth is .20” (5).
7. Remote inhibit requires an external 5 V @ 10 mA to activate.
8. Mounting maximum insertion depth is 0.12”.
4.00
(101.6)
1.5
(38.1)
.75 (19.0)
.5625
7.0
(177.8)
6.5
(165.1)
2.5
(63.5)
#6-32 UNC (8 places)
5.5
(139.7)
4.7
(119.6)
M3 (4 places)
SK5
123
5V adj
VR401 VR403
+3.3V
SK6
SK1
COMMON
+5V
M 3.5
(3 places)
MAIN OUTPUTS
5 3 1
SK2SK3SK4
3.3V adj
67891
12345
0
Case 5
(Weight: 1.25 lbs/0.57 kg approx.)
Case 6
(Weight: 1.38 lbs/0.63 kg approx.)
(See notes 7 & 8)
Power Supplies
3
Contact Technical Services at (800) 377-4384 with any questions.
Visit our website at www.solahd.com.
154
GL Series Dimensions (continued)
Notes:
1. Specications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02” .
3. Mounting holes MH1, MH2 and MH3 should be grounded for EMI purposes.
4. Mounting hole M1 is safety ground connection.
5. This power supply requires mounting on metal standoffs 0.20” (5 m) in height.
6. Specications are for convection rating at factory settings at 115 Vac input 25°C unless otherwise stated.
7. Mounting screw maximum insertion depth is 0.12”.
0.20 (5.0)
1.29
(32.8)
2.55
(64.8)
4.55
(115.6)
SK1
610
SK3
15
SK2
LIVE
NEUTRAL
GRD
P1
1
2
SK3
V
Adjust
POT
3.00
(76.2)
5.00
(127.0)
M3.5 (2 places)
0.15 DIA. (4.0)
(4 places)
(See notes 6 & 7)
Case 7
(Weight: .71 lbs/0.32 kg approx.)
SK1
N
L
GND
SK6
SK2
MAIN
OUTPUT
(2X) (119.6)
5.50
(2X) (139.7)
7.00
(177.8)
M3 (8 Places)
#6-32 (8 Places)
2.50
(4X) (63.5)
#6-32
6.75
(171.5)
6.36
(161.5)
M3
1.50
(38.1)
(3X) (19.1)
.75
4.71
V4 Adj - Course
#6-32
1.15
(29.1)
M3
.25
(2X) (6.4)
4.00
(101.6)
610
15
1 6
+12V OUT
COMM
-12V OUT
COMM
V4+
V4-
V4 Adj - Fine
V1 Adj
-CF option
Case 8
(Weight: 1.63 lbs/0.74 kg approx.)
Power Supplies 3
Contact Technical Services at (800) 377-4384 with any questions.
Visit our website at www.solahd.com.
155
GL Series Dimensions (continued)
Notes:
1. Specications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02” .
3. Specications are for convection rating at factory settings unless otherwise stated.
4. Remote inhibit requires an external 5 V @ 10 mA to activate.
5. Mounting (6-32) maximum insertion depth is 0.12”.
4.25
(108.0)
1.5
(38.1)
.75 (19.0)
.5625
SK3
8.5
(216.0)
7.4
(188.0)
2.5
(63.5)
.875
(22.25)
SK2
SK4
21 7 6 5
5 3 1
SK1
1234
8765
#6-32 (8 places)
Do Not
Adjust
Output
Adjust
Case 9
(Weight: 1.75 lbs/0.80 kg approx.)
Case 10
(Weight: 1.75 lbs/0.80 kg approx.)
Power Supplies
3
Contact Technical Services at (800) 377-4384 with any questions.
Visit our website at www.solahd.com.
156
GL Series Dimensions (continued)
531
SK4
15
610
SK1
+ -
SK3
Voltage Adj
POT
8.5
(216.0)
7.4
(188.0)
6.61
(168.0)
0.55
(14.0)
0.95
(24.0)
1.50
(38.1)
0.75
(19.0)
M3
#6-32
0.88
(22.2)
2.50
(63.5)
1.07
(27.2)
2.11
(53.5)
#6-32(8 PLACES)
M3(8 PLACES)
4.25
(108.0)
Notes:
1. Specications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02” .
3. Specifications are for convection rating at factory settings at 115 Vac input, 25°C unless otherwise stated.
4. Mounting screw maximum insertion depth is 0.12”.
5. Mounting holes M1 and M2 should be grounded for EMI purposes.
6. Mounting hole M1 is safety ground connection.
Case 11
(Weight: 0.5 lb/0.23 kg approx.)
SK4
SK1SK2
4.25
(108.0)
TB2
TB1
SK3
8.5
(216.0)
15
610
123456789
135
7.4
(188.0)
6.61
(168.0)
0.55
(14.0)
0.95
(24.0)
1.50
(38.1)
0.75
(19.0)
0.88
(22.2)
2.50
(63.5)
1.07
(27.2)
2.11
(53.5)
#6-32(8 PLACES)
M3(8 PLACES)
SK2 SK1
SK3
SK2 SK1
V1 (3V3-5V7)
V1 O/P ADJ.
V4 O/P ADJ.
V3 O/P ADJ.
CFV4 (3V3-25V)
V3 (-12V TO -15V7)
LPQ172 LPQ173
TB1
TB3
TB2
TB4
V2
V2
COM
V3
COM
COM
POK
N/C
N/C
V4 V1
SK3
P251
P252
Case 12
(Weight: 2 lbs/0.91 kg approx.)
(See notes 1-4)
Power Supplies 3
Contact Technical Services at (800) 377-4384 with any questions.
Visit our website at www.solahd.com.
157
Notes:
1. Specications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02” .
3. Specications are at factory settings.
4. To enable normally closed remote inhibit, cut jumper J1.
5. Mounting maximum insertion depth is 0.12”.
5.0 (127.0) 2.0
(50.8)
1.18 (30.0)
9.0
(228.6)
6.64
(168.6)
3.42 (87.0)
.79
(20)
SK3
SK1
12345678
3 2 1
SK5
+ve -ve
Terminal
Block TB1
O/P ADJ.
SK4
FAN
#6-32 (4 places)
5.46
(138.6)
8.52
(216.4)
M3 (4 places)
3.68
(93.6)
3.15
(80)
2.17
(55)
3.0
(76.2)
.55
(14) 1.30
(33.0)
Optional
(-CF)
Cover
with Fan
Optional
(-CEF)
Cover
with fans
10.32
(262.0)
SK7
FAN
AC Inlet
10.0
10.0
M3
#6-32 UNC
(2 places)
M3 10.0
#6-32 UNC
(2 places)
.24 (6.1)
6-32 (2 places)
Main Output
6-32 (3 places)
Case 13
(Weight: 2.6 lbs/1.19 kg approx.)
Case 14
(Weight: 3.1 lbs/1.41 kg approx.)
5.0 (127.0) 2.0
(50.8)
1.18 (30.0)
9.0
(228.6)
6.64
(168.6)
3.42 (87.0)
.79
(20)
SK3
SK1
12345678
3 2 1
SK5
+ve -ve
Terminal
Block TB1
O/P ADJ.
SK4
FAN
#6-32 UNC (8 places)
5.46
(138.6)
8.52
(216.4)
M3 (8 places)
3.68
(93.6)
3.15
(80)
2.17
(55)
3.0
(76.2)
.55
(14) 1.30
(33.0)
Optional
(-CF)
Cover
with Fan
Optional
(-CEF)
Cover
with fans
10.32
(262.0)
SK7
FAN
AC Inlet
10.0
10.0
10.0
M3
#6-32 UNC (2 places)
#6-32 UNC
(2 places)
#6-32 (2 places)
M3 (2 places)
4th O/P ADJ.
.24 (6.1)
6-32 (2 places)
Main Output
6-32 (3 places)
SK2
6 5 4 3 2 1
M3
(6 places)
M3
GL Series Dimensions (continued)
Power Supplies
3
Contact Technical Services at (800) 377-4384 with any questions.
Visit our website at www.solahd.com.
158
Notes:
1. Specications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02” .
3. Specications are at factory settings.
4. To enable normally closed remote inhibit, cut jumper J1.
5. Mounting maximum insertion depth is 0.12”.
9.0
(228.6)
6.64
(168.6)
3.42 (87.0)
.79
(20)
M3 (6 places)
SK3
12345678910
SK6
FAN
+ve -ve
Terminal
Block TB1
O/P ADJ.
SK5
FAN
#6-32 UNC (8 places)
5.46
(138.6)
8.52
(216.4)
M3 (4 places)
3.68
(93.6)
3.15
(80)
2.17
(55)
.55
(14) 1.30
(33.0)
(-CF)
Cover
with Fan
SK4
5.0 (127.0) 2.5
(63.5)
1.18 (30.0)
3.64
(92.5)
Optional
(-CEF)
Cover
with fans
.24 (6.1)
6-32 (2 places)
Main Output
10.43
(265.0)
5.0 (127.0)
3 2 1
SK1
6-32 (3 places)
Case 15
(Weight: 3.6 lbs/1.64 kg approx.)
5.0 (127.0) 2.5
(63.5)
1.18 (30.0)
3.5
(88.9)
Optional
(-CEF)
Cover
with fan
9.0
(228.6)
6.64
(168.6)
3.42 (87.0)
.79
(20)
SK1
3 2 1
SK5 5V aux
+ve -ve
Terminal
Block TB1
SK4 fan
#6-32 UNC (8 places)
5.46
(138.6)
8.52
(216.4)
M3 (4 places)
3.68
(93.6)
3.15
(80)
2.17
(55)
.55
(14) 1.30
(33.0)
Optional
(-CF)
Cover
with Fan
10.78
(273.8)
••
.24 (6.1)
6-32 (2 places)
Main Output
SK3
12345678910
SK6
SK2
6 5 4 3 2 1
6-32 (3 places)
(6 places)
Top pot.
=V4 adjust
Bottom pot.
=V1 adjust
Case 16
(Weight: 4 lbs/1.8 kg approx.)
GL Series Dimensions (continued)
Power Supplies 3
Contact Technical Services at (800) 377-4384 with any questions.
Visit our website at www.solahd.com.
159
CN1
SK7
SK8
(CN403)
V out adj.
Notes:
1. Specications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02” .
3. Specications are at factory settings.
4. Mounting maximum insertion depth is 0.12”.
Case 17
(Weight: 3.016 lbs/1.18 kg approx.)
GL Series Dimensions (continued)
1A
2A
3A *
4A
5A *
Connector GLS22 GLS23 GLS24
SK1 PIN 1 Line
PIN 3 Neutral
SK2
PIN 1 +5 V +12 V +15 V
PIN 2 +5 V +12 V +15 V
PIN 3 +5 V +12 V +15 V
PIN 4 Common
PIN 5 Common
PIN 6 Common
SK201 PIN 1 +Sense
PIN 2 -Sense
Connector GLT22 GLT23 GLT24 GLT25
SK1 PIN 1 Line
PIN 3 Neutral
SK2
PIN 1 +12 V +12 V +12 V +15 V
PIN 2 +5 V +5 V +5 V +5 V
PIN 3 +5 V +5 V +5 V +5 V
PIN 4 Common
PIN 5 Common
PIN 6 -12 V -12 V -5 V -15 V
SK201 PIN 1 +Sense
PIN 2 -Sense
Connector GLS42 GLS43 GLS44 GLS45
SK1 PIN 1 Line
PIN 3 Neutral
SK2
PIN 1 +5 V +12 V +15 V +24 V
PIN 2 +5 V +12 V +15 V +24 V
PIN 3 +5 V +12 V +15 V +24 V
PIN 4 Common
PIN 5 Common
PIN 6 Common
SK201 PIN 1 +Sense
PIN 2 -Sense
Connector GLT52 GLT53 GLT54
SK1 PIN 1 Neutral
PIN 3 Line
SK2
PIN 1 +5 V
PIN 2 +5 V
PIN 3 Common
PIN 4 Common
PIN 5 -12 V -15 V +12 V
PIN 6 +12 V +15 V +24 V
GL Series Pin Assignments
GL Series Pin Assignments (continued)
Connector GLT42 * GLT43 GLT44 GLT45 GLT45 *
SK1 PIN 1 Line
PIN 3 Neutral
SK2
PIN 1 +12 V +15 V +24 V
PIN 2 +5 V
PIN 3 +5 V
PIN 4 Common
PIN 5 Common
PIN 6 -12 V -5 V -15 V +12 V
SK201 PIN 1 +Sense
PIN 2 -Sense
* Same Pin Assignments are attributed to both the non-medical and medical models.
Power Supplies
3
Contact Technical Services at (800) 377-4384 with any questions.
Visit our website at www.solahd.com.
160
6A * 7A 8A
9A 10A
Connector GLS52 GLS53 GLS54 GLS55 GLS58
SK1 PIN 1 Line
PIN 3 Neutral
SK2
PIN 1 +5 V +12 V +15 V +24 V +48 V
PIN 2 +5 V +12 V +15 V +24 V +48 V
PIN 3 Common
PIN 4 Common
PIN 5 -Sense
PIN 6 +Sense
Connector GLS62 GLS63
(GLS62-M)
GLS64
(GLS63-M) GLS65
SK1 PIN 1 Neutral
PIN 3 Line
SK2
PIN 1 5 V +12 V +15 V +24 V
PIN 2 5 V +12 V +15 V +24 V
PIN 3 5 V +12 V +15 V +24 V
PIN 4 Common
PIN 5 Common
PIN 6 Common
SK201 PIN 1 +Sense
PIN 2 -Sense
Connector GLT62 GLT63 GLT64 GLT65
SK1 PIN 1 Neutral
PIN 3 Line
SK2
PIN 1 +12 V +15 V +12 V +24 V
PIN 2 +5 V +5 V +5 V +5 V
PIN 3 +5 V +5 V +5 V +5 V
PIN 4 Common
PIN 5 Common
PIN 6 -12 V -15 V -5 V +12 V
SK201 PIN 1 +Sense
PIN 2 -Sense
GL Series Pin Assignments (continued)
Connector GLS114 GLS115
SK1
PIN 1 Ground
PIN 3 Neutral
PIN 5 Line
SK2
PIN 1 +15 V +24 V
PIN 2 +15 V +24 V
PIN 3 +15 V +24 V
PIN 4 Common
PIN 5 Common
PIN 6 Common
PIN 7 Common
PIN 8 +15 V +24 V
PIN 9 +15 V +24 V
SK201 PIN 1 +Sense
PIN 2 -Sense
SK202 PIN 1 Power OK
PIN 2 Ground
Connector GLQ112 GLQ113 GLQ114
SK1
PIN 1 Ground
PIN 3 Neutral
PIN 5 Line
SK2
PIN 1 +5 V
PIN 2 +5 V
PIN 3 +5 V
PIN 4 Common
PIN 5 Common
PIN 6 Common
PIN 7 Common
PIN 8 +12 V +15 V +12 V
PIN 9 +12 V +15 V +12 V
PIN 10-12 V -15 V -12 V
PIN 11 +5-25 V +5-25 V +24 V
PIN 12 -5-25 V -5-25 V Common
SK201 PIN 1 +Sense
PIN 2 -Sense
SK202 PIN 1 Power OK
PIN 2 Ground
11A
12A
Connector GLQ123
SK1
PIN 1 Ground
PIN 3 Neutral
PIN 5 Line
SK5
PIN 1 +12 V
PIN 2 Common
PIN 3 -12 V
SK6
PIN 1 3.3 V Single Wire Parallel
PIN 2 -3.3 V Sense
PIN 3 +3.3 V +Sense
PIN 4 5 V Single Wire Parallel
PIN 5 Common
PIN 6 +5 V Sense
PIN 7 -5 V Sense
PIN 8 + Inhibit
PIN 9 - Inhibit
PIN 10 Power Fail
Connector GLS120
SK1 PIN 1 Neutral
PIN 3 Line
SK2 TB-1 Common
TB-2 Main Output
SK3
PIN 1 +V1 Remote Sense
PIN 2 -V1 Remote Sense
PIN 3 +Remote Inhibit
PIN 4 -Remote Inhibit
PIN 5 +Power Fail
PIN 6 Common
PIN 7 Single Wire Parallel
PIN 8 +12 V
PIN 9 12 V Common
PIN 10 +5 V Standby
* Same Pin Assignments are attributed to both the
non-medical and medical models.
Power Supplies 3
Contact Technical Services at (800) 377-4384 with any questions.
Visit our website at www.solahd.com.
161
GL Series Pin Assignments (continued)
14A 15A
16A *
Connector GLS152 GLS153 GLS155
SK1 PIN 1 Inhibit -ve
PIN 2 Inhibit +ve
PIN 3 VCC
PIN 4 No Connection
PIN 5 Common
PIN 6 -Sense
PIN 7 +Sense
PIN 8 Current Share
SK2 PIN 5 Common
PIN 6 Pin Removed
PIN 7 Power OK
SK3 TB-1 Common
TB-2 +5 V +12 V to
+15 V
+24 V to
+28 V
SK4 PIN 1 Ground
PIN 3 Line
PIN 5 Neutral
Connector GLQ152 GLQ153 GLQ154
SK1 PIN 1 Inhibit -ve
PIN 2 Inhibit +ve
PIN 3 +12 V +15 V +12V
PIN 4 No Connection
PIN 5 Common
PIN 6 -Sense
PIN 7 +Sense
PIN 8 I Share
SK2 PIN 1,2 +12 V +15 V +12 V
PIN
3,4,5 Common Common Common
PIN 6 -12 V -15 V -12 V
PIN 7 Power OK
PIN 8 +5 V to +25 V (Float) +24 V
PIN 9 Common (Float) Common
SK3 TB-1 Common
TB-2 +5 V
SK4 PIN 1 Ground
PIN 3 Line
PIN 5 Neutral
Connector GLS17x
SK1 PIN 1 +12 V
PIN 2 5 V Standby
PIN 3 Common
PIN 4 V1 Single Wire Parallel
PIN 5 Common
PIN 6 +V1 Sense
PIN 7 Sense Common
PIN 8 Remote Inhibit
PIN 9 DC Power Good
PIN 10 Power OK
SK2 TB-1 Common
TB-2 Main Output
SK3 PIN 1 Ground
PIN 2 Line
PIN 5 Neutral
17A 18A
Connector GLQ172 GLQ173
SK1 PIN 1 No Connection V4 Single Wire
Parallel
PIN 2 5 V Standby
PIN 3 No Connection +V4 Sense
PIN 4 V1 Single Wire Parallel
PIN 5 Common
PIN 6 +V1 Sense
PIN 7 Sense Common
PIN 8 Remote Inhibit
PIN 9 DC Power Good
PIN 10 Power OK
SK2 PIN 1,2 +12 V
PIN
3,4,5 Common
PIN 6 -12 V
PIN 7 Power OK
PIN 8 +3.3 V to +25
V (Float) No Connection
PIN 9 Common
(Float) No Connection
SK3 TB-1,3 Common
TB-2 +5 V (3.3 V to 5.5 V)
TB-4 No Connection +5 V (3.3 V to
5.5 V)
SK4 PIN 1 Ground
PIN 3 Line
PIN 5 Neutral
Connector GLS250
SK1
PIN 1 Neutral
PIN 2 Line
PIN 3 Ground
SK3
PIN 1 +Remote Sense
PIN 2 -Remote Sense
PIN 3 Remote Inhibit (N.O)
PIN 4 Remote Inhibit (N.C)
PIN 5 Common
PIN 6 Current Share
PIN 7 Power Fail
PIN 8 DC Power Good
SK4
PIN 1 +Fan’s power source
(12 V @ 500 mA)
PIN 2 -Fan’s power source
(12 V @ 500 mA)
SK5
PIN 1 +Supervisory output supply
(5 V @ 100 mA)
PIN 2 -Supervisory output supply
(5 V @ 100 mA)
SK7
PIN 1 +Fan’s power source
(12 V @ 500 mA)
PIN 2 +Fan’s power source
(12 V @ 500 mA)
13A
Connector GLQ142
SK1 PIN 1 Ground
PIN 3 Neutral
PIN 5 Line
SK2 PIN 1 +12 V
PIN 2 Common
PIN 3 -12 V
PIN 4 Common
PIN 5 +5 V to +25 V (Float)
PIN 6 Common (Float)
SK4 TB-1 Common
TB-2 +5 V
SK3 PIN 1 No Connection
PIN 2 DC Power Good
PIN 3 No Connection
PIN 4 V1 Single Wire Parallel
PIN 5 Common
PIN 6 +V1 Sense
PIN 7 Sense Common
PIN 8 +Inhibit
PIN 9 -Inhibit
PIN 10 Power Fail
* Same Pin Assignments are attributed to both the
non-medical and medical models.
Power Supplies
3
Contact Technical Services at (800) 377-4384 with any questions.
Visit our website at www.solahd.com.
162
GL Series Pin Assignments (continued)
19A
Connector GLQ250
SK1
PIN 1 Neutral
PIN 2 Line
PIN 3 Ground
SK2
PIN 1 +12 / 15 V
PIN 2 Common
PIN 3 Common
PIN 4 -12 / 15 V
PIN 5 5-25 V RET Float
PIN 6 5-25 V Float
SK3
PIN 1 +Remote Sense
PIN 2 -Remote Sense
PIN 3 Remote Inhibit (N.O.)
PIN 4 Remote Inhibit (N.C.)
PIN 5 Common
PIN 6 Current Share
PIN 7 Power Fail
PIN 8 DC Power Good
SK4 PIN 1 +Fan’s power source (12 V @ 500 mA)
PIN 2 +Fan’s power source (12 V @ 500 mA)
SK5
PIN 1 +Supervisory output supply
(5 V @ 100 mA)
PIN 2 -Supervisory output supply
(5 V @ 100 mA)
SK7 PIN 1 +Fan’s power source (12 V @ 500 mA)
PIN 2 +Fan’s power source (12 V @ 500 mA)
* Same Pin Assignments are attributed to both the
non-medical and medical models.
21A
20A
Connector GLQ350
SK1
PIN 1 Neutral
PIN 2 Line
PIN 3 Ground
SK2
PIN 1 +12 / 15 V
PIN 2 Common
PIN 3 Common
PIN 4 -12 / 15 V
PIN 5 3.3-25 V RET Float
PIN 6 3.3-25 V Float
SK3
PIN 1 +Sense V4
PIN 2 -Sense V4
PIN 3 +Sense V1
PIN 4 -Sense V1
PIN 5 Power OK
PIN 6 Current Share
PIN 7 DC Power Good
PIN 8 Inhibit (N.O.)
PIN 9 Inhibit (N.C.)
PIN 10 Common
SK4 PIN 1 +Fan 1 (12 V @ 150 mA)
PIN 2 -Common
SK5 PIN 1 +5 V aux (5 V@ 100 mA)
PIN 2 -Common
SK6 PIN 1 +Fan 2 (12 V @ 150 mA)
PIN 2 -Common
Connector GLS350
SK1
PIN 1 Neutral
PIN 2 Line
PIN 3 Ground
SK3
PIN 1 No Connection
PIN 2 No Connection
PIN 3 +Sense
PIN 4 -Sense
PIN 5 Power OK
PIN 6 Current Share
PIN 7 DC Power Good
PIN 8 Inhibit (N.O.)
PIN 9 Inhibit (N.C.)
PIN 10 Common
SK4 PIN 1 +5 V aux (5 V @ 100 mA)
PIN 2 -Common
SK5 PIN 1 +Fan 1 (12 V @ 150 mA)
PIN 2 -Common
SK6 PIN 1 +Fan 2 (12 V @ 150 mA)
PIN 2 -Common
22A *
Connector GL500
CN1 PIN 1 Line
PIN 3 Neutral
PIN 5 Ground
SK7 PIN 1 V1 Single Wire Parallel
PIN 2 -Remote Sense
PIN 3 +Remote Sense
PIN 4 5 VSB (Standby)
PIN 5 5 VSB Return
PIN 6 +12 V
PIN 7 Common
PIN 8 Inhibit
PIN 9 DC Power Good
PIN 10 Power Fail (POK)
CN403 PIN 1 5 V_I2C
PIN 2 Ground
PIN 3 A2
PIN 4 A0
PIN 5 SVCC2_OR
PIN 6 I2C_SDA
PIN 7 I2C_SLC
PIN 8 A1
PIN 9 No Connection
PIN 10 +12V_RTN_CTRL
Adjustment Potentiometers
P1 +V1 Output Adjust
Power Supplies 3
Contact Technical Services at (800) 377-4384 with any questions.
Visit our website at www.solahd.com.
163
7B 9B
8B
Connector Kit #70-841-012 includes the
following:
(SK1)
AC Input:
Molex 09-50-8051 (USA)
09-91-0500 (UK)
PINS: 08-58-0111
SK2,3,4: Molex series 19141-0058/0063
(SK5)
±12V:
Molex: 09-50-8031 (USA)
Molex: 09-91-0300 (UK)
PINS: 08-58-0111
(SK6)
Control
Signals:
Molex: 90142-0010;
PINS: 90119-2110 or
AMP: 87977-3; PINS: 87309-8
Connector Kit #70-841-017 includes the
following:
(SK1)
AC Input:
Molex 09-50-8051 (USA)
09-91-0500 (UK)
PINS: 08-58-0111
(SK2) Aux
DC Outputs:
Molex: 09-50-8061 (USA)
Molex: 09-91-0600 (UK)
PINS: 08-58-0111
(SK6)
Control
Signals:
Molex: 90142-0010 (USA)
PINS: 90119-2110 or
AMP: 87977-3
PINS: 87309-8
(SK4)
Main Output: Molex: BB-124-08
Connector Kit #70-841-020 includes the
following:
(SK1)
AC Input:
Molex 09-50-8031 (connector)
PINS: 08-52-0113
(SK2)
DC Outputs:
Molex series 19141-
0058/0063 Spade lug
(SK3)
Control
Signals:
Molex: 90142-0010 (USA)
PINS: 90119-2110 or
AMP: 87977-3
PINS: 87309-8
1B * 2B *
Connector Kit #70-841-006 includes the
following:
AC Input:
Molex 09-50-8031 (USA)
Not required for (-T) option
09-91-0300 (UK)
PINS: 08-52-0113
(-0111 for medical)
DC
Outputs:
Molex 09-50-8061 (USA)
Not required for (-T) option
09-91-0600 (UK)
PINS: 08-52-0113
(-0111 for medical)
Remote
Sense:
Molex 22-01-2025
PINS: 08-52-0123
(-0114 for medical)
Connector Kit #70-841-006 includes the
following:
AC Input:
Molex 09-50-8031 (USA)
09-91-0300 (UK)
PINS: 08-52-0113
DC Outputs:
Molex 09-50-8061 (USA)
09-91-0600 (UK)
PINS: 08-52-0113
GL Series Mating Connectors
3B *
Connector Kit #70-841-006 includes the
following:
AC Input:
Molex 09-50-8031 (USA)
Not required for (-T) option
09-91-0300 (UK)
PINS: 08-58-0111
(-0113 for medical)
DC
Outputs:
Molex 09-50-8061 (USA)
Not required for (-T) option
09-91-0600 (UK)
PINS: 08-58-0113
Remote
Sense:
Molex 22-01-2025
PINS: 08-52-0113
4B *
Connector Kit #70-841-006 includes the
following:
AC Input:
Molex 09-50-8031 (USA)
09-91-0300 (UK)
PINS: 08-58-0111
DC
Outputs:
Molex 09-50-8061 (USA)
09-91-0600 (UK)
PINS: 08-52-0113
Remote
Sense:
Molex 22-01-2025
PINS: 08-52-0113
5B 6B
Connector Kit #70-841-007 includes the
following:
AC Input:
Molex 09-50-8051 (USA)
09-91-0500 (UK)
PINS: 08-58-0111
DC
Outputs:
Molex 09-50-8091 (USA)
09-91-0900 (UK)
PINS: 08-58-0111
Remote Sense/
Power Fail:
Molex 22-01-1022 (USA)
22-01-1023 (UK)
PINS: 08-50-0114
Connector Kit #70-841-008 includes the
following:
AC Input:
Molex 09-50-8051 (USA)
09-91-0500 (UK)
PINS: 08-58-0111
DC
Outputs:
Molex 09-50-8121 (USA)
09-91-1200 (UK)
PINS: 08-58-0111
Remote
Sense/
Power Fail:
Molex 22-01-1022 (USA)
22-01-1023 (UK)
PINS: 08-50-0114
* Same Mating Connectors are attributed to both standard
and medical models.
Power Supplies
3
Contact Technical Services at (800) 377-4384 with any questions.
Visit our website at www.solahd.com.
164
GL Series Mating Connectors (continued)
11B
13B 14B 15B
16B 17B
12B *
Connector Kit #70-841-010 includes the
following:
(SK4)
AC Input:
Molex: 09-50-8051 (USA)
Molex:09-91-0500 (UK)
PINS: 08-58-0111
(SK2) Aux DC
Outputs/
Power Fail:
Molex: 09-50-8091 (USA)
Molex: 09-91-0900 (UK)
PINS: 08-58-0111
(SK1)
Remote Sense/
Remote Inhibit:
Molex 51110-0851 (USA)
PINS: 503-94-8100
Connector Kit #70-841-016 includes the
following:
(SK4)
AC Input:
Molex: 09-50-8051 (USA)
Molex:09-91-0500 (UK)
PINS: 08-58-0111
(SK3)
DC Outputs: Molex: 19141-0058
(SK1)
Remote Sense/
Remote Inhibit:
Molex 90142-0010 (USA)
PINS: 90119-2110
Amp: 87977-3
PINS: 87309-8
Connector Kit #70-841-015 includes the
following:
(SK4)
AC Input:
Molex 09-50-8051 (USA)
Molex:09-91-0500 (UK)
PINS: 08-58-0111
(SK3)
Main Output: Molex series 19141-0058/0063
(SK2) Aux
DC Outputs/
Power Fail:
Molex 09-50-8091 (USA)
Molex:09-91-0900 (UK)
PINS: 08-58-0111
(SK1)
Control
Signals:
Molex: 90142-0010 (USA)
PINS: 90119-2110 or
AMP: 87977-3
PINS: 87309-8
Connector Kit #70-841-005 includes the
following:
SK3 Molex 22-01-1084; PINS: 08-70-0057
SK4 Molex 22-01-3027; PINS: 08-50-0114
SK5 Molex 22-01-3027; PINS:08-50-0114
SK7 Molex: 22-01-3027 PINS: 08-50-0114
Connector Kit #70-841-011 includes the
following:
SK3 Molex 22-01-1104; PINS: 08-70-0057
SK4 Molex 22-01-3027; PINS: 08-50-0114
SK5 Molex 22-01-3027; PINS:08-50-0114
SK6 Molex: 22-01-3027; PINS: 08-50-0114
Connector Kit #70-841-011 includes the
following:
SK3 Molex 22-01-1084; PINS: 08-70-0057
SK4 Molex 22-01-3027; PINS: 08-50-0114
SK5 Molex 22-01-3027; PINS:08-50-0114
SK6 Molex: 22-01-3027; PINS: 08-50-0114
Connector Kit #70-841-024 includes the
following:
SK4,5,6 Molex 19141-0058
SK7
Control
Signals
Molex 90142-0010;
PINS: 90119-2110 or
AMP: 87977-3; PINS: 87309-8
SK8 Molex 22-01-2025; PINS:08-52-0123
CN403
JST PHDR-10VS
PINS: JST 5PHD-002T-PO.5-L/P
or
Landwin 2050 S1000;
PINS: 2053T011P
10B
Connector Kit #70-841-009 includes the
following:
(SK4) AC Input:
Molex: 09-50-8051 (USA)
Molex:09-91-0500 (UK)
PINS: 08-58-0111
(SK2) Power Fail:
Molex: 09-50-8031 (USA)
Molex: 09-91-0300 (UK)
PINS: 08-58-0111
(SK1)
Remote Sense/
Remote Inhibit:
Molex 51110-0851 (USA)
PINS: 50394-8100
* Same Mating Connectors are attributed to both standard
and medical models.
Power Supplies 3
Contact Technical Services at (800) 377-4384 with any questions.
Visit our website at www.solahd.com.
165
GL Compact Series: Single Output Switchers
GL100-M Series GL200-M Series
Input
Input Voltage 90 - 264 Vac; 120 - 300 Vdc
Frequency 47-63 Hz
Inrush Current 50 A max., cold start @ 25°C
Efficiency 88% typical at full load
EMI/RFI FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE0878PT3 Class B conducted
Power Factor 0.99 typical
Safety Ground
Leakage Current 275 uA @ 50/60 Hz, 264 Vac input
Output
Power 100 W convection (80 W for GLS102-M) 125 W for convection; 200W
Adjustment Range on
Main Output ±10% minimum on the main outputs
Fan Output 12 V @ 1 A isolated, ±5%
Hold-up Time 10 ms @ 150 W load, 120 Vac input 16 ms @ 250 W load, 120 Vac input
Overload Short circuit protection on all outputs. Case overload protected @ 110-160% above rating
Overvoltage Protection 15-35% above nominal output
Logical Control
Power Failure Open collector logic signal goes high 100-500 msec after main output; it goes low at least 6 msec before loss of regulation
Remote Sense Compensates for 0.5 V lead drop minimum; Will operate without remote sense connected, Reverse connection
General
Temperature Storage: -40°C to +85°C; Operating: 0° to 50°C ambient. Derate each output 2.5% per degree from 50° to 70°C, -20°C start up.
Electromagnetic
Susceptibility Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3
Humidity Operating; non-condensing 10% to 95% RH
Vibration IEC68-2-6 to the levels of IEC721-3-2
MTBF >550,000 hours demonstrated at full load, and 25°C ambient conditions
Safety IEC/EN/UL 60950-1, IEC/EN/UL 60601-1
Specifications
The GL Compact Series combines both medical and
non-medical approvals into one unit. These models offer
very high reliability, high efciency, active Power Factor
Correction and very low ground leakage currentcompact size
Each model of GL100-M and GL200-M series complies with
the medical and ITE safety standards, enabling it to be used
for both medical or non-medical standard applications.
Features:
• Medical Approvals
• Smaller Size
• Dual Rating
• High demonstrated MTBF
• Automatic overvoltage protection
• Overload protection
• Extensive safety approvals
• Two year limited warranty
Power Supplies
3
Contact Technical Services at (800) 377-4384 with any questions.
Visit our website at www.solahd.com.
166
Medical and Non-Medical Series
Catalog
Number Description Output 1 Output 2 Output 3 Output 4 Case*Pin
Assignments*
Mating
Connectors*
GL100-M
GLS102-M 5 V 150W 2” X 4” 5 V @ 16 A [24 A] - - -
1 1A 1B
GLS103-M 12 V 150W 2” X 4” 12 V @ 8.3 A [12.5 A] - - -
GLS104-M 15 V 150W 2” X 4” 15 V @ 6.7 A [10 A] - - -
GLS105-M 24 V 150W 2” X 4” 24 V @ 4.2 A [6.3 A] - - -
GLS108-M 48 V 150W 2” X 4” 48 V @ 2.1 A [3.1 A] - - -
GL200-M
GLS202-M 5 V 250W 3” X 5” 5 V @ 20 A [40 A] - - -
2 2A 2B
GLS203-M 12 V 250W 3” X 5” 12 V @ 10.3 A [20.8 A] - - -
GLS204-M 15 V 250W 3” X 5” 15 V @ 8.3 A [16.6 A] - - -
GLS205-M 24 V 250W 3” X 5” 24 V @ 5.2 A [10.4 A] - - -
GLS208-M 48 V 250W 3” X 5” 48 V @ 2.6 A [5.2 A] - - -
Selection Table
GL Compact Series Dimensions
SK1
SK2
SK203
2.00"
(50.8)
4.00"
(101.6)
1.72"
(43.8)
1.29"
(33.0)
0.16"
(4.0)
3.73"
(94.7) Mounting Hole
Ø0.16"[4.0] 4 Places
Max. Screw Head
Diameter .22” (5.6)
M1 M2
GND
VR1
Output Voltage
Adjust Pot
SK5
0.197” (5.0) Minimum Standoff Height
1
3
41
8
1
4
1
1.32
(33.6)
5.00
(127.0)
3.00
(76.2)
2.55
(64.8)
0.15 Dia.
(4)
4 Places
4.55
(115.6)
21
SK2
SK3
SK3
VR1
Output Voltage
Adjust Pot
0.197” (5.0)
Minimum
Stando Height
5
110
MH1
MH2
Notes:
1. Specications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02” .
3. Mounting holes MH1, MH2, MH3 should be grounded for EMI purposes.
4. Mounting MH1 is safety ground connection.
5. Specications are for convection rating at factory settings at 115 Vac input 25°C unless otherwise stated.
6. This power supply requires mounting on metal standoffs 0.20” (5 m) in height.
Case 1
(Weight: 0.44 lb/0.20 kg approx.)
Case 2
(Weight: 0.75 lb/0.34 kg approx.)
* Refer to GL Series Dimensions and the sections that follow
Power Supplies 3
Contact Technical Services at (800) 377-4384 with any questions.
Visit our website at www.solahd.com.
167
1A 2A
Connector GLS102M GLS103M GLS104M GLS105M GLS108M
SK1 PIN 1 Neutral
PIN 3 Line
SK2
PIN 1 Ground
PIN 2 Ground
PIN 3 Ground
PIN 4 Ground
PIN 5
+5 +12 +15 +24 +48
PIN 6
PIN 7
PIN 8
SK 203
PIN 1 Ground
PIN 2 Power Fail
PIN 3 -Remote Sense
PIN 4 +Remote Sense
SK5
PIN 1 +12 V Fan
PIN 2 +12 V Fan
PIN 3 Fan Ground
PIN 4 Fan Ground
Connector GLS202M GLS203M GLS204M GLS205M GLS208M
SK1 PIN 1 Neutral
PIN 3 Line
SK2 TB-1 Common
TB-2 +5 +12 +15 +24 +48
SK3
PIN 1 +V1 Remote Sense
PIN 2 -V1 Remote Sense
PIN 3 No Connection
PIN 4 No Connection
PIN 5 +Power Fail
PIN 6 Common
SK 203
PIN 7 No Connection
PIN 8 Common
PIN 9 +12 V Fan
PIN 10 +12 V Fan Ground
GL Compact Series Pin Assignments
GL Compact Series Mating Connectors
1B 2B
Connector Kit #70-841-025 includes the following:
(SK1)
AC Input: Molex P/N 09-50-3031 or Landwin P/N: 3060S0302
(SK2)
DC Outputs: Molex P/N 09-50-3081 or Landwin P/N: 3060S0802
(SK203)
Remote Sense: Molex P/N 35155-0400 or Landwin P/N: 2640S04A0
(SK5) Fan: Molex P/N 22-10-2047 or Landwin P/N: 2510S0400
Connector Kit #70-841-018 includes the following:
(SK1)
AC Input:
Molex 09-50-8031 (connector)
PINS: 08-52-0113
(SK2)
DC Outputs:
Molex 19141-0058/0063
Spade lug
(SK3)
Control Signals:
Molex: 90142-0010 (USA)
PINS: 90119-2110 or
Amp: 87977-3 / PINS: 87309-8