POWER
LPS60 Series
60 Watts
Total Power: 60 - 80 Watts
Input Voltage: 85 - 264 Vac
120 - 300 Vdc
# of Outputs: Single
Special FeatureS
Universal input
3” x 5” footprint
Remote sense
Built in EMI lter
Low output ripple
Adjustable output voltage
Overload protection
110 KHz switching frequency
RoHS compliant
LPX60 enclosure kit available
SaFety
UL UL 60950-1
CAN/ CSA-C22.2 60950-1
E132002
NEMKO EN 60950-1
CB IEC 60950-1
CE Mark (LVD)
Electrical Specications
Input
Input range 85 - 264 Vac (wide range)
120 - 300 Vdc
Frequency 47-440 Hz
Inrush current <18 A peak @ 115 Vac, <36 A peak @230 Vac, cold start @ 25 °C
Input current 1.5 A max. (RMS) @ 115 Vac
Efficiency 70% typical at full load
EMI filter FCC Class B conducted; CISPR 22 Class B conducted; EN55022
Class B conducted; VDE0878PT3 Class B conducted
Safety ground
leakage current
<0.5 mA @ 50/60 Hz; 264 Vac input
Output
Maximum power 60 W for convection; 80 W with 30 CFM forced air
Adjustment range -5, +10% minimum
Hold-up time 20 ms @ 60 W load, 115 Vac nominal line
Overload protection Short circuit protection on all outputs.
Case overload protected @ 110-145% above peak rating
Overvoltage protection 5 V output; 5.7 - 6.7 Vdc.
Other outputs 10% to 25% above nominal output
Remote sense Compensates for 0.5 V lead drop min. Will operate without remote
sense connected. Reverse connection protected.
Data Sheet
LPS60 Series Data Sheet
Environmental Specications
Operating temperature 0° to 50 °C ambient derate each output as 2.5%
per degree from 50° to 70 °C, -20 °C startup
Storage temperature -40 °C to +85 °C
Electromagnetic
susceptibility
Designed to meet IEC61000-4-2, -4-3, -4-4,
-4-5, -4-6, Level 3
Humidity Operating; non-condensing 5% to 95% RH
Vibration
Three orthogonal axes, sweep at 1 cot/min,
5 min. dwell at four major resonances 0.75 G
peak 5 Hz to 500 Hz, operational
Temperature coefcient ±0.04% per °C
MTBF demonstrated >550,000 hours at full load and 25 °C ambient
conditions
Power Derating Curve
Output
Power
(Watts)
0°C
20W
40W
60W
80W
10°C 20°C 30°C 40°C 50°C 60°C 70°C
TA – Ambient Temperature – °C
0W
Natural
Convection
Cooling
40W
30W
30 CFM Forced Air Cooling
Mechanical Drawings
3.00"
(76.2)
2.55"
(64.8)
0.22"
(5.6)
0.22"
(5.6)
4.56"
(115.8) 5.00"
(127)
1.65"
(41.9)
0.12"
(3)
SK 1
SK 2
1
2
3
4
5
6
0.15" (4)
DIA (4 places)
GND
3
1
N
L
M1
M2
Remote Sense
Connector
_
+
SK201
Voltage
Adj. Pot
LPS60 Series Data Sheet
WORLDWIDE OFFICES
Americas
2900 South Diablo Way
Suite B100
Tempe, AZ 85282, USA
+1 888 412 7832
Europe (UK)
Ground Floor Offices, Barberry House
4 Harbour Buildings, Waterfront West
Brierley Hill, West Midlands
DY5 1LN, UK
+44 (0) 1384 842 211
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
+852 2176 3333
For more information: www.artesyn.com
For support: productsupport.ep@artesyn.com
Artesyn Embedded Technologies, Artesyn Embedded Power, Artesyn, and all Artesyn related logos are
trademarks and service marks of Artesyn Embedded Technologies, Inc. All other names and logos referred to are
trade names, trademarks, or registered trademarks of their respective owners. Specifications are subject to
change without notice. © 2019 Artesyn Embedded Technologies, Inc. All rights reserved. For full legal terms and
conditions, please visit www.artesyn.com/legal.
www.artesyn.com
LPS60 Series-DS 20Dec2019
Pin Assignments
Connector
LPS61 LPS62 LPS63 LPS64 LPS65 LPS68
SK1-1 Line Line Line Line Line Line
SK1-3 Neutral Neutral Neutral Neutral Neutral Neutral
SK2-1 3.3 V 5 V +12 V +15 V +24 V 48 V
SK2-2 3.3 V 5 V +12 V +15 V +24 V 48 V
SK2-3 3.3 V 5 V +12 V +15 V +24 V 48 V
SK2-4 Common Common Common Common Common Common
SK2-5 Common Common Common Common Common Common
SK2-6 Common Common Common Common Common Common
SK201-1 +Sense +Sense +Sense +Sense +Sense +Sense
SK201-2 -Sense -Sense -Sense -Sense -Sense -Sense
Mating Connectors
AC Input
Molex 09-50-8031 (USA) Not required for (-T) option
09-91-0300 (UK)
PINS: 08-58-0111
DC Outputs
Molex 09-50-8061 (USA) Not required for (-T) option
09-93-0600 (UK)
PINS: 08-52-0113
Remote
Sense
Molex 22-01-2025
PINS: 08-52-0113
Astec Connector Kit #70-841-006, includes all of the above
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02”(± 0.5mm)
3. Mounting holes M1 and M2 should be grounded for EMI purposes.
4. Mounting hole M1 is safety ground connection.
5. Specifications are for convection rating at factory settings at
115 Vac input, 25°C unless otherwise stated.
6. Warranty: 2 years
7. Weight: 0.75 lbs/0.34 kg
Ordering Information
Model Number Output
Voltage
Minimum
Load
Maximum Load with
Convection Cooling
Maximum Load with
30CFM Forced Air Peak Load1Regulation2Ripple
P/P (PARD)3
LPS61 3.3 V 2 A 12 A 16 A 18 A ±2% 33 mV
LPS62 5 V 0 A 12 A 16 A 18 A ±2% 50 mV
LPS63 12 V 0 A 5 A 6.7 A 7.5 A ±2% 120 mV
LPS64 15 V 0 A 4 A 5.3 A 6 A ±2% 150 mV
LPS65 24 V 0 A 2.5 A 3.3 A 3.8 A ±2% 240 mV
LPS68 48 V 0 A 1.3 A 1.7 A 1.9 A ±2% 480 mV
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 μF (tantalum capacitor) in parallel with a 0.1 μF capacitor at rated line voltage and load ranges.
4. This product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated
as a standalone product. EMC compliance to appropriate standards must be verified at the system level. This product is for sale to OEMs and
System Integrators, including through Distribution Channels. It is not intended for sale to End Users.