High Surge Current (D-rated) SIDACtor Device
http://www.littelfuse.com 2 - 10 © 2004 Littelfuse, Inc.
+1 972-580-7777 SIDACtor® Data Book and Design Guide
High Surge Current (D-rated) SIDACtor Device
DO-214AA SIDACtor solid state protection devices with a D surge rating protect
telecommunications equipment such as modems, line cards, fax machines, and other CPE.
These SIDACtor devices withstand simultaneous surges incurred in GR 1089 lightning
tests. (See "First Level Lightning Surge Test" on page 4-5.) Surge ratings are twice that of a
device with a C surge rating. This allows a discrete surface mount version of Littelfuse’s
patented “Y” configuration. (US Patent 4,905,119)
SIDACtor devices are used to enable equipment to meet various regulatory requirements
including GR 1089, ITU K.20, K.21 and K.45, IEC 60950, UL 60950, and TIA-968-A
(formerly known as FCC Part 68).
* For surge ratings, see table below.
** Contact factory for release date.
*** The 2.2 A version cannot be used to meet 4.4 A requirements.
General Notes:
All measurements are made at an ambient temperature of 25 °C. IPP applies to -40 °C through +85 °C temperature range.
• IPP is a repetitive surge rating and is guaranteed for the life of the product.
• Listed SIDACtor devices are bi-directional. All electrical parameters and surge ratings apply to forward and reverse polarities.
• VDRM is measured at IDRM.
• VS is measured at 100 V/µs.
Special voltage (VS and VDRM) and holding current (IH) requirements are available upon request.
• Off-state capacitance (CO) is measured at 1 MHz with a 2 V bias and is a typical value.
Electrical Parameters
Part
Number *
VDRM
Volts
VS
Volts
VT
Volts
IDRM
µAmps
IS
mAmps
IT
Amps ***
IH
mAmps
CO
pF
P0080SD ** 6 25 4 5 800 2.2 50 200
P0300SD ** 25 40 4 5 800 2.2 50 220
P0640SD ** 58 77 4 5 800 2.2 50 100
P0720SD ** 65 88 4 5 800 2.2 50 100
P0900SD ** 75 98 4 5 800 2.2 50 100
P1100SD 90 130 4 5 800 2.2 50 80
P1300SD 120 160 4 5 800 2.2 50 80
P1500SD 140 180 4 5 800 2.2 50 80
P1800SD 170 220 4 5 800 2.2 50 60
P2300SD 190 260 4 5 800 2.2 50 60
P2600SD 220 300 4 5 800 2.2 50 60
P3100SD 275 350 4 5 800 2.2 50 60
P3500SD 320 400 4 5 800 2.2 50 60
Surge Ratings
Series
IPP
2x10 µs
Amps
IPP
8x20 µs
Amps
IPP
10x160 µs
Amps
IPP
10x560 µs
Amps
IPP
10x1000 µs
Amps
ITSM
60 Hz
Amps
di/dt
Amps/µs
D 1000 800 400 300 200 50 1000
High Surge Current (D-rated) SIDACtor Device
© 2004 Littelfuse, Inc. 2 - 11 http://www.littelfuse.com
SIDACtor® Data Book and Design Guide +1 972-580-7777
Data Sheets
Thermal Considerations
Package Symbol Parameter Value Unit
DO-214AA TJOperating Junction Temperature Range -40 to +150 °C
TSStorage Temperature Range -65 to +150 °C
RθJA Thermal Resistance: Junction to Ambient 90 °C/W
IH
IT
IS
IDRM
VDRM
VT
+V
-V
+I
-I
VS
IH
IT
IS
IDRM
VDRM
VT
+V
-V
+I
-I
VS
V-I Characteristics
50
100
0t
r
t
d
0
Peak
Value
Half Value
t – Time (µs)
I
PP
– Peak Pulse Current – %I
PP
t
r
= rise time to peak value
t
d
= decay time to half value
Waveform = t
r
x t
d
tr x td Pulse Wave-form
-8-40 -20 0 20 40 60 80 100 120 140 160
-6
-4
0
2
4
6
8
10
12
14
Junction Temperature (T
J
) – ˚C
Percent of V
S
Change – %
25 ˚C
Normalized VS Change versus Junction Temperature
0.4-40 -20 0 20 40 60 80 100 120 140 160
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
Case Temperature (T
C
) – ˚C
Ratio of I
H
I
H
(T
C
= 25 ˚C)
25 ˚C
Normalized DC Holding Current versus Case Temperature