Data Sheet August 23, 2010 QRW025 Series Power Modules; dc-dc Converters 36Vdc - 75Vdc Input; 1.2 to 3.3 Vdc Output; 25A RoHS Compliant Applications Enterprise Networks Wireless Networks Access and Optical Network Equipment Enterprise Networks Latest generation IC's (DSP, FPGA, ASIC) and Microprocessor-powered applications. Options Features Compliant to RoHS EU Directive 2002/95/EC (-Z versions) Compliant to ROHS EU Directive 2002/95/EC with lead solder exemption (non-Z versions) Delivers up to 25A output current Ultra High efficiency - 91% at 3.3V full load Industry standard DOSA Compliant Quarter brick: 57.9 mm x 36.8 mm x 9.5 mm (2.28 in x 1.45 in x 0.375 in) Improved Thermal Performance: 25A at 70C at 1m/s (200LFM) for 3.3Vo High power density Low output ripple and noise Low output voltages down to 1V: Supports migration to future IC and microprocessor supply voltages 2:1 input voltage Remote Sense Remote On/Off Constant switching frequency Output overvoltage and Overcurrent protection Overtemperature protection Positive Remote On/Off logic Adjustable output voltage (+10% / -20%) Case ground pin (-H Base plate version) Auto restart after fault shutdown Meets the voltage isolation requirements for ETSI 300-132-2 and complies with and is licensed for Basic Insulation rating per EN60950-1 UL** 60950-1 Recognised, CSA C22.2 No. 60950 rd 1-03 Certified, and VDE 0805 (IEC60950, 3 Edition) Licensed CE mark meets 2006/95/EC directive ISO* 9001 certified manufacturing facilities Description The QRW-series dc-dc converters are a new generation of DC/DC power modules designed for optimum efficiency and power density. The QRW series provide up to 25A output current in an industry standard quarter brick, which makes it an ideal choice for small space, high current and low voltage applications. The converter uses synchronous rectification technology and innovative packaging techniques to achieve high efficiency reaching 91% at 3.3V full load. Thanks to the ultra high efficiency of this converter, the power dissipation is such that for most applications a heat sink is not required. In addition, the QRW-series supports future migration of semiconductor and microprocessor supply voltages down to 1.0V. * ISO is a registered trademark of the International Organization of Standards ** UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. This product is intended for integration into end-use equipment. All of the required procedures of end-use equipment should be followed. PDF name: QRW025_Series.pdf Data Sheet August 23, 2010 QRW025 Series Power Modules; dc-dc Converters 36 Vdc - 75 Vdc Input, 1.2 to 3.3 Vdc Output; 25A Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliabiltiy. Device Symbol Min Max Unit Input Voltage:Continuous Transient (100ms) Parameter All VI VI, trans -- -- 75 100 Vdc Vdc Operating Ambient Temperature (See Thermal Considerations section) All TA -40 85 C Storage Temperature All Tstg -55 125 C I/O Isolation Voltage (100% factory Hi-Pot tested) When using optional case ground pin (option 7) -- -- -- 1500 700 Vdc Vdc Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Device Symbol Min Typ Operating Input Voltage All VIN 36 48 75 Vdc Maximum Input Current (VI = 0 V to 75 V; IO = IO, max) All -- -- 2.8m n Adc Inrush Transient All 1 A 2s Input Reflected Ripple Current, peak-peak (5 Hz to 20 MHz, 12 H source impedance See Test configuration section) All 16 mAp-p Input Ripple Rejection (120 Hz) All 60 dB I2 t Max Unit CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple stand-alone operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a normal-blow fuse with a maximum rating of 10 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer's data for further information. Lineage Power 2 QRW025 Series Power Modules; dc-dc Converters 36 Vdc - 75 Vdc Input, 1.2 to 3.3 Vdc Output; 25A Data Sheet August 23, 2010 Electrical Specifications (continued) Output Specifications for the QRW025A0P (Vo = 1.2Vdc) Parameter Device Symbol Min Typ Max Unit Output Voltage Set Point (VI = 48 Vdc; IO = IO, min to IO, max, TA = 25 C) P Vo 1.18 1.2 1.22 Vdc Output Voltage (Over all operating input voltage, resistive load, and temperature conditions at steady state until end of life.) P Vo 1.15 -- 1.25 Vdc P -- -- -- -- -- -- 0.05 0.05 5 0.3 0.3 20 %, VO, set %, VO, set mV -- -- -- -- 30 100 mVrms mVp-p Output Regulation: Line (VI = VI, min to VI, max) Load (IO = IO, min to IO, max) Temperature (TA = TA, min to TA, max) Output Ripple and Noise RMS (5 Hz to 20 MHz bandwidth) Peak-to-peak (5 Hz to 20 MHz bandwidth) P External Load Capacitance -- 25,000 F Output Current (Vo =90% of VO, nom.) P IO 0.0 -- 25 Adc Output Current-limit Inception (VO = 90% of VO, set) P IO, lim -- 29 -- Adc -- 85 -- % fSW -- 300 -- kHz Output Short-circuit Current (Average)VO = 0.25 V Latched off Efficiency (VI = VIN, nom; IO = IO, max), TA = 25 C Switching Frequency All Dynamic Response (IO/t = 1 A/10 s, VI = 48 V, TA = 25 C); tested with a 220 F aluminium and a 1.0 f ceramic capacitor across the load.): Load Change from IO = 50% to 75% of IO, max: Peak Deviation Settling Time (VO < 10% of peak deviation) Load Change from IO = 50% to 25% of IO, max : Peak Deviation Settling Time (VO < 10% of peak deviation) 8 200 mV s 8 200 mV s Isolation Specifications Parameter Symbol Min Typ Max Unit Isolation Capacitance Ciso -- 5600 -- PF Isolation Resistance Riso 10 -- -- MW General Specifications Parameter Min Calculated MTBF (IO = 80% of IO, max TA = 40 C) Weight Lineage Power Typ Max 1,771,000 -- 37(1.31) Unit Hours -- g (oz.) 3 QRW025 Series Power Modules; dc-dc Converters 36 Vdc - 75 Vdc Input, 1.2 to 3.3 Vdc Output; 25A Data Sheet August 23, 2010 Feature Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See Feature Descriptions for additional information. Parameter Remote On/Off Signal Interface* (VI = 0 V to 75 V; open collector or equivalent compatible; signal referenced to VI(-) terminal; see Figure 34 and Feature Descriptions.): Preferred Logic: Logic Low--Module On Logic High--Module Off Optional Logic: Logic Low--Module Off Logic High--Module On Logic Low: At Ion/off = 1.0 mA At Von/off = 0.0 V Logic High: At Ion/off = 0.0 A Leakage Current Turn-on Time; see Typical Start-up Curve(IO = IO max; Vo within 1% of steady state) Output Voltage Adjustment (See Feature Descriptions): Output Voltage Remote-sense Range Output Voltage Set-point Adjustment Range (trim) Output Overvoltage Protection OvertemperaWuUe Protection (IO = IO, max) Lineage Power Symbol Min Typ Max Unit Von/off Ion/off 0 -- -- -- 1.2 1.0 V mA Von/off Ion/off -- -- -- -- 2 15 50 4 V A ms -- -- -- 80 -- -- 10 110 %VO,rated %V0,nom VO, ovsd Tref1 1.42 -- -- 127 1.58 -- V C 4 QRW025 Series Power Modules; dc-dc Converters 36 Vdc - 75 Vdc Input, 1.2 to 3.3 Vdc Output; 25A Data Sheet March 27, 2008 Characteristic Curves OUTPUT CURRENT, IO (A) OUTPUT VOLTAGE, VO (V) (5 A/div) (50 mV/div) The following figures provide typical characteristics curves for the QRW025A0P (VO = 1.2 V) module at room temperature (TA = 25 C).The figures are identical for both on/off configurations. 1.2 INPUT CURRENT, II (A) 1 IO = 25A 0.8 0.6 IO = 12.5A 0.4 IO = 2.5A 0.2 00 10 20 30 40 50 INPUT VOLTAGE, VI (V) 60 70 80 Figure 1. Input Voltage and Current Characteristics. TIME, t, (.2 s/div) Tested with a 220F aluminium and a 1.0F ceramic capacitor across the load. Figure 4. 90 80 EFFICIENCY, (%) 70 60 VI = 75V VI = 48V VI = 36V 50 40 30 20 10 0 0 5 10 15 20 25 OUTPUT CURRENT, IO (A) 30 Figure 2. Converter Efficiency vs. Output Current. OUTPUT CURRENT, IO (A) OUTPUT VOLTAGE, VO (V) (5 A/div) (50 mV/div) 100 Transient Response to Step decrease in Load from 50% to 25% of Full Load (VI = 48 Vdc). TIME, t, (.2 s/div) Figure 5. Transient Response to Step Increase in Load from 50% to 75% of Full Load (VI = 48 Vdc). 0.5 OUTPUT VOLTAGE, VO (V) (20 mV/div) 36V, 25A 48V, 25A 75V, 25A TIME, t (1 s/div) Figure 3. Output Ripple Voltage (IO = IO, max). Lineage Power Figure 6. Start-up from Remote On/Off (IO = IO, max). 5 QRW025 Series Power Modules; dc-dc Converters 36 Vdc - 75 Vdc Input, 1.2 to 3.3 Vdc Output; 25A Data Sheet August 23, 2010 Electrical Specifications (continued) Output Specifications for the QRW025AOM (Vo = 1.5Vdc) Device Symbol Min Typ Max Unit Output Voltage Set Point (VI = 48 Vdc; IO = IO, min to IO, max, TA = 25 C) Parameter M Vo 1.47 1.5 1.52 Vdc Output Voltage (Over all operating input voltage, resistive load, and temperature conditions at steady state until end of life.) M Vo 1.45 -- 1.55 Vdc M -- -- -- -- -- -- 0.05 0.05 15 0.2 0.2 50 %, VO, set %, VO, set mV -- -- -- -- 20 100 mVrms mVp-p -- 25,000 F Output Regulation: Line (VI = VI, min to VI, max) Load (IO = IO, min to IO, max) Temperature (TA = TA, min to TA, max) Output Ripple and Noise RMS (5 Hz to 20 MHz bandwidth) Peak-to-peak (5 Hz to 20 MHz bandwidth) M External Load Capacitance Output Current (Vo =90% of VO, nom.) M IO 0.0 -- 25 Adc Output Current-limit Inception (VO = 90% of VO, set) M IO, lim -- 30 -- Adc -- 87 -- % fSW -- 300 -- kHz Output Short-circuit Current (Average)VO = 0.25 V Latched off Efficiency (VI = VIN, nom; IO = IO, max), TA = 25 C Switching Frequency All Dynamic Response (DIO/Dt = 1 A/10 s, VI = 48 V, TA = 25 C); tested with a 220 F aluminium and a 1.0 f ceramic capacitor across the load.): Load Change from IO = 50% to 75% of IO, max: Peak Deviation Settling Time (VO < 10% of peak deviation) Load Change from IO = 50% to 25% of IO, max : Peak Deviation Settling Time (VO < 10% of peak deviation) 6 200 6 200 mV s mV s Isolation Specifications Symbol Min Typ Max Isolation Capacitance Parameter Ciso -- 5600 -- Unit PF Isolation Resistance Riso 10 -- -- MW General Specifications Parameter Min Calculated MTBF (IO = 80% of IO, max TA = 40 C) Weight Lineage Power Typ Max 1,715,000 -- 37(1.31) Unit Hours -- g (oz.) 6 QRW025 Series Power Modules; dc-dc Converters 36 Vdc - 75 Vdc Input, 1.2 to 3.3 Vdc Output; 25A Data Sheet August 23, 2010 Feature Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See Feature Descriptions for additional information. Parameter Remote On/Off Signal Interface* (VI = 0 V to 75 V; open collector or equivalent compatible; signal referenced to VI(-) terminal; see Figure 34 and Feature Descriptions.): Preferred Logic: Logic Low--Module On Logic High--Module Off Optional Logic: Logic Low--Module Off Logic High--Module On Logic Low: At Ion/off = 1.0 mA At Von/off = 0.0 V Logic High: At Ion/off = 0.0 A Leakage Current Turn-on Time; see Typical Start-up Curve(IO = IO max; Vo within 1% of steady state) Output Voltage Adjustment (See Feature Descriptions): Output Voltage Remote-sense Range Output Voltage Set-point Adjustment Range (trim) Output Overvoltage Protection OvertemperaWuUe Protection (IO = IO, max) Symbol Min Typ Max Unit Von/off Ion/off 0 -- -- -- 1.2 1.0 V mA Von/off Ion/off -- -- -- -- 2 15 50 4 V A ms -- -- -- 80 -- -- 10 110 %VO,rated %V0,nom VO, ovsd Tref1 1.69 -- -- 127 2.07 -- V C * A Minimum OFF Period of 1 sec is recommended. Lineage Power 7 QRW025 Series Power Modules; dc-dc Converters 36 Vdc - 75 Vdc Input, 1.2 to 3.3 Vdc Output; 25A Data Sheet August 23, 2010 Characteristic Curves INPUT CURRENT, II (A) 1.4 1.2 1 IO = 25 A 0.8 0.6 IO = 12.5 A 0.4 0.2 IO = 0 A 0 25 35 45 55 INPUT VOLTAGE, VI (V) 65 75 OUTPUT CURRENT, IO (A) (5 A/div) OUTPUT VOLTAGE, VO (V) (100 mV/idv) The following figures provide typical characteristics curves for the QRW025A0M (VO = 1.5 V) module at room temperature (TA = 25 C) TIME, t (50 s/div) Tested with a 220F aluminium and a 1.0F ceramic capacitor across the load. Figure 7. Input Voltage and Current Characteristics. Figure 10. Transient Response to Step Decrease in Load from 50% to 25% of Full Load (VI = 48 Vdc). 88 EFFICIENCY (%) 86 84 82 80 78 VI = 36 V VI = 48 V VI = 75 V 76 74 72 70 0 5 10 15 OUTPUT CURRENT, IO (A) 20 25 OUTPUT CURRENT, IO (A) (5 A/div) OUTPUT VOLTAGE, VO (V) (100 mV/idv) 90 Figure 8. Converter Efficiency vs. Output Current. TIME, t (50 s/div) Figure 11. Transient Response to Step Increase in Load from 50% to 75% of Full Load (VI = 48 Vdc). OUTPUT VOLTAGE, VO (V) (20 mV/idv) 0. 36V, 25A 48V, 25A 75V, 25A TIME, t (1 s/div) Figure 9. Output Ripple Voltage (IO = IO, max). Tested with a 10F aluminium and a 1.0F tantalum capacitor across the load. Figure 12. Start-up from Remote On/Off (IO = IO, max). Lineage Power 8 QRW025 Series Power Modules; dc-dc Converters 36 Vdc - 75 Vdc Input, 1.2 to 3.3 Vdc Output; 25A Data Sheet August 23, 2010 Electrical Specifications (continued) Output Specifications for the QRW025A0Y (Vo = 1.8Vdc) Device Symbol Min Typ Max Unit Output Voltage Set Point (VI = 48 Vdc; IO = IO, min to IO, max, TA = 25 C) Parameter Y Vo 1.77 1.8 1.83 Vdc Output Voltage (Over all operating input voltage, resistive load, and temperature conditions at steady state until end of life.) Y Vo 1.75 -- 1.85 Vdc Y -- -- -- -- -- -- 0.05 0.05 15 0.2 0.2 50 %, VO, set %, VO, set mV -- -- -- -- 35 100 mVrms mVp-p -- 25,000 F Output Regulation: Line (VI = VI, min to VI, max) Load (IO = IO, min to IO, max) Temperature (TA = TA, min to TA, max) Output Ripple and Noise RMS (5 Hz to 20 MHz bandwidth) Peak-to-peak (5 Hz to 20 MHz bandwidth) Y External Load Capacitance Output Current (Vo =90% of VO, nom.) Y IO 0.0 -- 25 Adc Output Current-limit Inception (VO = 90% of VO, set) Y IO, lim -- 30 -- Adc -- 88 -- % fSW -- 300 -- kHz Output Short-circuit Current (Average)VO = 0.25 V Latched off Efficiency (VI = VIN, nom; IO = IO, max), TA = 25 C Switching Frequency All Dynamic Response (DIO/Dt = 1 A/10 s, VI = 48 V, TA = 25 C); tested with a 220 F aluminium and a 1.0 f ceramic capacitor across the load.): Load Change from IO = 50% to 75% of IO, max: Peak Deviation Settling Time (VO < 10% of peak deviation) Load Change from IO = 50% to 25% of IO, max : Peak Deviation Settling Time (VO < 10% of peak deviation) 8 200 8 200 mV s mV s Isolation Specifications Symbol Min Typ Max Isolation Capacitance Parameter Ciso -- 5600 -- Unit PF Isolation Resistance Riso 10 -- -- MW General Specifications Parameter Min Calculated MTBF (IO = 80% of IO, max TA = 40 C) Weight Lineage Power Typ Max 1,644,000 -- 37(1.31) Unit Hours -- g (oz.) 9 QRW025 Series Power Modules; dc-dc Converters 36 Vdc - 75 Vdc Input, 1.2 to 3.3 Vdc Output; 25A Data Sheet August 23, 2010 Feature Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See Feature Descriptions for additional information. Parameter Remote On/Off Signal Interface* (VI = 0 V to 75 V; open collector or equivalent compatible; signal referenced to VI(-) terminal; see Figure 34 and Feature Descriptions.): Preferred Logic: Logic Low--Module On Logic High--Module Off Optional Logic: Logic Low--Module Off Logic High--Module On Logic Low: At Ion/off = 1.0 mA At Von/off = 0.0 V Logic High: At Ion/off = 0.0 A Leakage Current Turn-on Time; see Typical Start-up Curve(IO = IO max; Vo within 1% of steady state) Output Voltage Adjustment (See Feature Descriptions): Output Voltage Remote-sense Range Output Voltage Set-point Adjustment Range (trim) Output Overvoltage Protection OvertemperaWuUe Protection (IO = IO, max) Symbol Min Typ Max Unit Von/off Ion/off 0 -- -- -- 1.2 1.0 V mA Von/off Ion/off -- -- -- -- 4 15 50 8 V A ms -- -- -- 80 -- -- 10 110 %VO,rated %V0,nom VO, ovsd Tref1 2.0 -- -- 127 2.5 -- V C * A Minimum OFF Period of 1 sec is recommended. Lineage Power 10 QRW025 Series Power Modules; dc-dc Converters 36 Vdc - 75 Vdc Input, 1.2 to 3.3 Vdc Output; 25A Data Sheet August 23, 2010 Characteristic Curves 1.6 IO = 25 A IO = 12.5 A IO = 0 A 1 0.8 0.6 0.4 0.2 0 30 35 40 45 50 55 60 INPUT VOLTAGE, VI (V) 65 70 75 Figure 13. Input Voltage and Current Characteristics. 90 88 VI = 36 V EFFICENCY, (%) 86 84 82 80 78 VI = 75 V VI = 48 V 76 74 72 70 0 5 10 15 20 OUTPUT CURRENT, IO (A) Figure 14. Converter Efficiency vs. Output Current. VI = 36 V OUTPUT VOLTAGE, VO (V) (50 mV/div) TIME, t (100 s/div) Tested with a 220F aluminium and a 1.0F ceramic capacitor across the load. VI = 48 V VI = 75 V 25 Figure 16. Transient Response to Step Decrease in Load from 50% to 25% of Full Load (VI = 48 Vdc). OUTPUT CURRENT, IO (A) OUTPUT VOLTAGE, VO (V) (10 A/div) (100 mV/div) 25 TIME, t (100 s/div) Figure 17. Transient Response to Step Increase in Load from 50% to 75% of Full Load (VI = 48 Vdc). OUTPUT VOLTAGE, (V) (0.5 V/div) 1.2 REMOTE ON/OFF, VON/OFF (V) INPUT CURRENT, II (A) 1.4 OUTPUT CURRENT, IO (A) OUTPUT VOLTAGE, VO (V) (10 A/div) (100 mV/div) The following figures provide typical characteristics curves for the QRW025A0Y (VO = 1.8 V) module at room temperature (TA = 25 C) TIME, t (2 ms/div) TIME, t (1 s/div) Figure 15. Output Ripple Voltage (IO = IO, max). Lineage Power Tested with a 10F aluminium and a 1.0F tantalum capacitor across the load. Figure 18. Start-up from Remote On/Off (IO = IO, max). 11 QRW025 Series Power Modules; dc-dc Converters 36 Vdc - 75 Vdc Input, 1.2 to 3.3 Vdc Output; 25A Data Sheet August 23, 2010 Electrical Specifications (continued) Output Specifications for the QRW025A0G (Vo = 2.5Vdc) Device Symbol Min Typ Max Unit Output Voltage Set Point (VI = 48 Vdc; IO = IO, min to IO, max, TA = 25 C) Parameter G Vo 2.47 2.5 2.53 Vdc Output Voltage (Over all operating input voltage, resistive load, and temperature conditions at steady state until end of life.) G Vo 2.42 -- 2.58 Vdc G -- -- -- -- -- -- 0.05 0.05 15 0.2 0.2 50 %, VO, set %, VO, set mV -- -- -- -- 35 100 mVrms mVp-p -- 25,000 F Output Regulation: Line (VI = VI, min to VI, max) Load (IO = IO, min to IO, max) Temperature (TA = TA, min to TA, max) Output Ripple and Noise RMS (5 Hz to 20 MHz bandwidth) Peak-to-peak (5 Hz to 20 MHz bandwidth) G External Load Capacitance Output Current (Vo =90% of VO, nom.) G IO 0.0 -- 25 Adc Output Current-limit Inception (VO = 90% of VO, set) G IO, lim -- 30 -- Adc -- 90 -- % fSW -- 300 -- kHz Output Short-circuit Current (Average)VO = 0.25 V Latched off Efficiency (VI = VIN, nom; IO = IO, max), TA = 25 C Switching Frequency All Dynamic Response (DIO/Dt = 1 A/10 s, VI = 48 V, TA = 25 C); tested with a 220 F aluminium and a 1.0 f ceramic capacitor across the load.): Load Change from IO = 50% to 75% of IO, max: Peak Deviation Settling Time (VO < 10% of peak deviation) Load Change from IO = 50% to 25% of IO, max : Peak Deviation Settling Time (VO < 10% of peak deviation) 5 200 5 200 mV s mV s Isolation Specifications Symbol Min Typ Max Isolation Capacitance Parameter Ciso -- 5600 -- Unit PF Isolation Resistance Riso 10 -- -- MW General Specifications Parameter Min Calculated MTBF (IO = 80% of IO, max TA = 40 C) Weight Lineage Power Typ Max 1,558,000 -- 37(1.31) Unit Hours -- g (oz.) 12 QRW025 Series Power Modules; dc-dc Converters 36 Vdc - 75 Vdc Input, 1.2 to 3.3 Vdc Output; 25A Data Sheet August 23, 2010 Feature Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See Feature Descriptions for additional information. Parameter Remote On/Off Signal Interface* (VI = 0 V to 75 V; open collector or equivalent compatible; signal referenced to VI(-) terminal; see Figure 52 and Feature Descriptions.): Preferred Logic: Logic Low--Module On Logic High--Module Off Optional Logic: Logic Low--Module Off Logic High--Module On Logic Low: At Ion/off = 1.0 mA At Von/off = 0.0 V Logic High: At Ion/off = 0.0 A Leakage Current Turn-on Time; see Typical Start-up Curve(IO = IO max; Vo within 1% of steady state) Output Voltage Adjustment (See Feature Descriptions): Output Voltage Remote-sense Range Output Voltage Set-point Adjustment Range (trim) Output Overvoltage Protection OvertemperaWuUe Protection (IO = IO, max) Symbol Min Typ Max Unit Von/off Ion/off 0 -- -- -- 1.2 1.0 V mA Von/off Ion/off -- -- -- -- 2 15 50 4 V A ms -- -- -- 80 -- -- 10 110 %VO,rated %V0,nom VO, ovsd Tref1 2.9 -- -- 127 3.2 -- V C * A Minimum OFF Period of 1 sec is recommended. Lineage Power 13 QRW025 Series Power Modules; dc-dc Converters 36 Vdc - 75 Vdc Input, 1.2 to 3.3 Vdc Output; 25A Data Sheet August 23, 2010 Characteristic Curves OUTPUT CURRENT, IO (A) OUTPUT VOLTAGE, VO (V) (5 A/div) (100 mV/div) The following figures provide typical characteristics curves for the QRW025A0G (VO = 2.5 V) module at room temperature (TA = 25 C) 2 INPUT CURRENT, II (A) 1.8 1.6 1.4 1.2 IO = 25 A 1 0.8 IO = 12.5 A 0.6 0.4 0.2 0 IO = 0 A 25 35 45 55 65 75 INPUT VOLTAGE, VI (V) TIME, t (100 s/div) Tested with a 220F aluminium and a 1.0F ceramic capacitor across the load. 95 VI = 36 V EFFICIENCY (%) 90 85 80 VI = 48 V VI = 75 V 75 70 0 5 10 15 OUTPUT CURRENT, IO (A) 20 TIME, t (100 s/div) Figure 23. Transient Response to Step Increase in Load from 50% to 75% of Full Load (VI = 48 Vdc). OUTPUT VOLTAGE, VO (V) (50 mV/div) REMOTE ON/OFF, OUTPUT VOLTAGE, VO (V) Von/off (V) (1 V/div) Figure 20. Converter Efficiency vs. Output Current. 25 OUTPUT CURRENT, IO (A) OUTPUT VOLTAGE, VO (V) (5 A/div) (100 mV/div) Figure 22. Transient Response to Step Decrease in Load from 50% to 25% of Full Load (VI = 48 Vdc). Figure 19. Input Voltage and Current Characteristics. TIME, t (1 ms/div) TIME, t (1 s/div) Figure 21. Output Ripple Voltage (IO = IO, max). Lineage Power Tested with a 10F aluminium and a 1.0F tantalum capacitor across the load. Figure 24. Start-up from Remote On/Off (IO = IO, max). 14 QRW025 Series Power Modules; dc-dc Converters 36 Vdc - 75 Vdc Input, 1.2 to 3.3 Vdc Output; 25A Data Sheet August 23, 2010 Electrical Specifications (continued) Output Specifications for the QRW025A0F (Vo = 3.3Vdc) Device Symbol Min Typ Max Unit Output Voltage Set Point (VI = 48 Vdc; IO = IO, min to IO, max, TA = 25 C) Parameter F Vo 3.24 3.3 3.36 Vdc Output Voltage (Over all operating input voltage, resistive load, and temperature conditions at steady state until end of life.) F Vo 3.2 -- 3.4 Vdc F -- -- -- -- -- -- 0.05 0.05 15 0.2 0.2 50 %, VO, set %, VO, set mV -- -- -- -- 30 100 mVrms mVp-p -- 30,000 F Output Regulation: Line (VI = VI, min to VI, max) Load (IO = IO, min to IO, max) Temperature (TA = TA, min to TA, max) Output Ripple and Noise RMS (5 Hz to 20 MHz bandwidth) Peak-to-peak (5 Hz to 20 MHz bandwidth) F External Load Capacitance Output Current (Vo =90% of VO, nom.) F IO 0.0 -- 25 Adc Output Current-limit Inception (VO = 90% of VO, set) F IO, lim -- 28 -- Adc -- 91 -- % fSW -- 300 -- kHz Output Short-circuit Current (Average)VO = 0.25 V Latched off Efficiency (VI = VIN, nom; IO = IO, max), TA = 25 C Switching Frequency All Dynamic Response (DIO/Dt = 1 A/10 s, VI = 48 V, TA = 25 C); tested with a 220 F aluminium and a 1.0 f ceramic capacitor across the load.): Load Change from IO = 50% to 75% of IO, max: Peak Deviation Settling Time (VO < 10% of peak deviation) Load Change from IO = 50% to 25% of IO, max : Peak Deviation Settling Time (VO < 10% of peak deviation) 5 200 5 200 mV s mV s Isolation Specifications Symbol Min Typ Max Isolation Capacitance Parameter Ciso -- 5600 -- Unit PF Isolation Resistance Riso 10 -- -- MW General Specifications Parameter Min Calculated MTBF (IO = 80% of IO, max TA = 40 C) Weight Lineage Power Typ Max 1,548,000 -- 37(1.31) Unit Hours -- g (oz.) 15 QRW025 Series Power Modules; dc-dc Converters 36 Vdc - 75 Vdc Input, 1.2 to 3.3 Vdc Output; 25A Data Sheet August 23, 2010 Feature Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See Feature Descriptions for additional information. Parameter Remote On/Off Signal Interface* (VI = 0 V to 75 V; open collector or equivalent compatible; signal referenced to VI(-) terminal; see Figure 34 and Feature Descriptions.): Preferred Logic: Logic Low--Module On Logic High--Module Off Optional Logic: Logic Low--Module Off Logic High--Module On Logic Low: At Ion/off = 1.0 mA At Von/off = 0.0 V Logic High: At Ion/off = 0.0 A Leakage Current Turn-on Time; see Typical Start-up Curve(IO = IO max; Vo within 1% of steady state) Output Voltage Adjustment (See Feature Descriptions): Output Voltage Remote-sense Range Output Voltage Set-point Adjustment Range (trim) Output Overvoltage Protection OvertemperaWuUe Protection (IO = IO, max) Symbol Min Typ Max Unit Von/off Ion/off 0 -- -- -- 1.2 1.0 V mA Von/off Ion/off -- -- -- -- 2 15 50 4 V A ms -- -- -- 80 -- -- 10 110 VO, ovsd Tref1 3.8 -- -- 127 4.6 -- %V0,nom %V0,nom V C * A Minimum OFF Period of 1 sec is recommended. Lineage Power 16 QRW025 Series Power Modules; dc-dc Converters 36 Vdc - 75 Vdc Input, 1.2 to 3.3 Vdc Output; 25A Data Sheet August 23, 2010 Characteristic Curves The following figures provide typical characteristics curves for the QRW025A0F (VO = 3.3 V) module at room temperature (TA = 25 C) 3 .5 3 I O = 25 A I O = 12 .5 A I O = 2.5 A INPUT CURRENT, II (A) 2 .5 2 1 .5 1 0 .5 0 0 10 20 30 40 50 60 70 IN P U T V OL T A G E , V I (V ) Tested with a 220F aluminium and a 1.0F ceramic capacitor across the load. Figure 25. Input Voltage and Current Characteristics. Figure 28. Transient Response to Step Decrease in Load from 50% to 25% of Full Load (VI = 48 Vdc). 95 EFFICENCY, (%) 90 85 VI = 36 V VI = 48 V VI = 75 V 80 75 70 0 5 10 15 20 25 30 OUTPUT CURRENT, IO (A) Figure 26. Converter Efficiency vs. Output Current. OUTPUT VOLTAGE (V) REMOTE ON/OFF (1 V/div) VON/OFF (V) OUTPUT VOLTAGE, VO (V) (50 mV/div) 36V, 25A Figure 29. Transient Response to Step Increase in Load from 50% to 75% of Full Load (VI = 48 Vdc). 48V, 25A 75V, 25A TIME, t (2 ms/div) TIME, t (2s/div) Figure 27. Output Ripple Voltage (IO = IO, max). Lineage Power Tested with a 10F aluminium and a 1.0F tantalum capacitor across the load. Figure 30. Start-up from Remote On/Off (IO = IO, max). 17 QRW025 Series Power Modules; dc-dc Converters 36 Vdc - 75 Vdc Input, 1.2 to 3.3 Vdc Output; 25A Data Sheet August 23, 2010 Test Configurations Design Considerations TO OSCILLOSCOPE Input Source Impedance CURRENT PROBE LTEST 12 H VI(+) CS 220 F ESR < 0.1 @ 20 C 100 kHz BATTERY VI(-) Note:Measure input reflected-ripple current with a simulated source inductance (LTEST) of 12 H. Capacitor CS offsets possible battery impedance. Measure current as shown above. Figure 31. Input Reflected-Ripple Test Setup. COPPER STRIPS VO(+) 1.0 F 10 F SCOPE RESISTIVE LOAD VO(-) Note:Use a 1.0 F ceramic capacitor and a 10 F aluminum or tantalum capacitor. Scope measurement should be made using a BNC socket. Position the load between 51 mm and 76 mm (2 in. and 3 in.) from the module. Figure 32. Peak-to-Peak Output Noise Measurement Test Setup. SENSE(+) VI(+) CONTACT AND DISTRIBUTION LOSSES VO(+) IO II SUPPLY LOAD VI(-) CONTACT RESISTANCE VO(-) SENSE(-) Note:All measurements are taken at the module terminals. When socketing, place Kelvin connections at module terminals to avoid measurement errors due to socket contact resistance. [ V O (+) - V O (-) ]I O = ---------------------------------------------- x 100 % [ V I (+) - V I (-) ]I I Figure 33. Output Voltage and Efficiency Measurement. The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. For the test configuration in 31, a 33 F electrolytic capacitor (ESR < 0.7 W at 100 kHz) mounted close to the power module helps ensure stability of the unit. For other highly inductive source impedances, consult the factory for further application guidelines. Output Capacitance High output current transient rate of change (high di/dt) loads may require high values of output capacitance to supply the instantaneous energy requirement to the load. Tp minimize the output voltage transient drop during this transient, low E.S.R. (equivalent series resistance) capacitors may be required, since a high E.S.R. will produce a correspondingly higher voltage drop during the current transient. Output capacitance and load impedance interact with the power module's output voltage regulation control system and may produce an 'unstable' output condition for the required values of capacitance and E.S.R.. Minimum and maximum values of output capacitance and of the capacitor's associated E.S.R. may be dictated, depending on the module's control system. The process of determining the acceptable values of capacitance and E.S.R. is complex and is load-dependant. Lineage provides Web-based tools to assist the power module enduser in appraising and adjusting the effect of various load conditions and output capacitances on specific power modules for various load conditions. Safety Considerations For safety-agency approval of the system in which the power module is used, the power module must be installed in compliance with the spacing and separation requirements of the end-use safety agency standard, i.e., UL60950, CSA C22.2 No. 60950-00, and VDE 0805:2001-12 (IEC60950, 3rd Ed). These converters have been evaluated to the spacing requirements for Basic Insulation, per the above safety standards; and 1500 Vdc is applied from VI to VO to 100% of outgoing production. For end products connected to -48 Vdc, or -60 Vdc nomianl DC MAINS (i.e. central office dc battery plant), no further fault testing is required. Note:-60 V dc nominal bettery plants are not available in the U.S. or Canada. For all input voltages, other than DC MAINS, where the input voltage is less than 60 Vdc, if the input meets all of the requirements for SELV, then: n Lineage Power The output may be considered SELV. Output voltages will 18 Data Sheet August 23, 2010 QRW025 Series Power Modules; dc-dc Converters 36 Vdc - 75 Vdc Input, 1.2 to 3.3 Vdc Output; 25A remain withing SELV limits even with internally-generated non-SELV voltages. Single component failure and fault tests were performed in the power converters. n One pole of the input and one pole of the output are to be grounded, or both circuits are to be kept floating, to maintain the output voltage to ground voltage within ELV or SELV limits. For all input sources, other than DC MAINS, where the input voltage is between 60 and 75 Vdc (Classified as TNV-2 in Europe), the following must be adhered to, if the converter's output is to be evaluated for SELV: n n n The input source is to be provided with reinforced insulation from any hazardous voltage, including the AC mains. One VI pin and one VO pin are to be reliably earthed, or both the input and output pins are to be kept floating. Another SELV reliability test is conducted on the whole system, as required by the safety agencies, on the combination of supply source and the subject module to verify that under a single fault, hazardous voltages do not appear at the module's output. The power module has ELV (extra-low voltage) outputs when all inputs are ELV. All flammable materials used in the manufacturing of these modules are rated 94V-0, and UL60950A.2 for reduced thicknesses. The input to these units is to be provided with a maximum 10A normal-blow fuse in the ungrounded lead. Lineage Power 19 QRW025 Series Power Modules; dc-dc Converters 36 Vdc - 75 Vdc Input, 1.2 to 3.3 Vdc Output; 25A Data Sheet August 23, 2010 Feature Descriptions [Vo(+) - Vo(-)] - [SENSE(+) - SENSE(-)] 10% of Vo, rated Overcurrent Protection To provide protection in a fault output overload condition, the module is equipped with internal current-limiting circuitry and can endure current limit for few seconds. If overcurrent persists for few seconds, the module will shut down and remain latch-off. The overcurrent latch is reset by either cycling the input power or by toggling the on/off pin for one second. If the output overload condition still exists when the module restarts, it will shut down again. This operation will continue indefinitely until the overcurrent condition is corrected. An auto-restart option is also available. Remote On/Off Two remote on/off options are available. Positive logic remote on/off turns the module on during a logic-high voltage on the ON/OFF pin, and off during a logic low. Negative logic remote on/off turns the module off during a logic high and on during a logic low. Negative logic, device code suffix "1," is the factory-preferred configuration. To turn the power module on and off, the user must supply a switch to control the voltage between the on/off terminal and the VI(-) terminal (Von/off). The switch can be an open collector or equivalent (see Figure 10). A logic low is Von/off = 0 V to I.2 V. The maximum Ion/off during a logic low is 1 mA. The switch should maintain a logic-low voltage while sinking 1 mA. During a logic high, the maximum Von/off generated by the power module is 15 V. The maximum allowable leakage current of the switch at Von/off = 15V is 50 A. If not using the remote on/off feature, do one of the following to turn the unit on For negative logic, short ON/OFF pin to VI(-). For positive logic: leave ON/OFF pin open. Ion/off + SENSE(+) VO(+) LOAD VI(+) VI(-) VO(-) SENSE(-) Figure 34. Remote On/Off Implementation. Remote Sense Remote sense minimizes the effects of distribution losses by regulating the voltage at the remote-sense connections. The voltage between the remote-sense pins and the output terminals must not exceed the output voltage sense range given in the Feature Specifications table i.e.: Lineage Power If not using the remote-sense feature to regulate the output at the point of load, then connect SENSE(+) to Vo(+) and SENSE(-) to Vo(-) at the module. Although the output voltage can be increased by both the remote sense and by tine trim, the maximum increase for the output voltage is not the sum of both. The maximum increase is the larger of either the remote sense or the trim. The amount of power delivered by the module is defined as the voltage at the output terminals multiplied by the output current. When using remote sense and trim: the output voltage of the module can be increased, which at the same output current would increase the power output of the module. Care should be taken to ensure that the maximum output power of the module remains at or below the maximum rated power. SENSE(+) SENSE(-) SUPPLY II CONTACT RESISTANCE VI(+) VO(+) VI(-) VO(-) IO LOAD CONTACT AND DISTRIBUTION LOSSES Figure 35. Effective Circuit Configuration for Single-Module Remote-Sense Operation Output Voltage. Output Overvoltage Protection ON/OFF Von/off - The voltage between the Vo(+) and Vo(-) terminals must not exceed the minimum output overvoltage shutdown value indicated in the Feature Specifications table. This limit includes any increase in voltage due to remote-sense compensation and output voltage set-point adjustment (trim). See Figure 35. The output overvoltage protection consists of circuitry that monitors the voltage on the output terminals. If the voltage on the output terminals exceeds the over voltage protection threshold, then the module will shutdown and latch off. The overvoltage latch is reset by either cycling the input power for one second or by toggling the on/off signal for one second. The protection mechanism is such that the unit can continue in this condition until the fault is cleared. Overtemperature Protection These modules feature an overtemperature protection circuit to safeguard against thermal damage. The circuit shuts down and latches off the module when the maximum device reference temperature is exceeded. The module can be restarted by cycling the dc input power for at least one second or by toggling the remote on/off signal for at least one second. 20 Data Sheet August 23, 2010 QRW025 Series Power Modules; dc-dc Converters 36 Vdc - 75 Vdc Input, 1.2 to 3.3 Vdc Output; 25A Feature Descriptions (Continued) Output Voltage Set-Point Adjustment (Trim) Trimming allows the user to increase or decrease the output voltage set point of a module. This is accomplished by connecting an external resistor between the TRIM pin and either the SENSE(+) or SENSE(-) pins. The trim resistor should be positioned close to the module. If not using the trim feature, leave the TRIM pin open. With an external resistor between the TRIM and SENSE(-) pins (Radj-down), the output voltage set point (Vo,adj) decreases (see Figure 36). The following equation determines the required external-resistor value to obtain a percentage output voltage change of %. For Output Voltage: 1.2V - 12V With an external resistor connected between the TRIM and SENSE(+) pins (Radj-up), the output voltage set point (Vo,adj) increases (see Figure 37). The following equation determines the required externalresistor value to obtain a percentage output voltage change of D% For Output Voltage: 1.5V - 12V For Output Voltage: 1.2V VI(+) ON/OFF CASE VI(-) VO(+) SENSE(+) TRIM Radj-down RLOAD SENSE(-) VO(-) Figure 36. Circuit Configuration to Decrease Output Voltage. VI(+) ON/OFF CASE VI(-) VO(+) SENSE(+) TRIM Radj-up RLOAD SENSE(-) VO(-) Figure 37. Circuit Configuration to Increase Output Voltage. The voltage between the Vo(+) and Vo(-) terminals must not exceed the minimum output overvoltage shut-down value indicated in the Feature Specifications table. This limit includes any increase in voltage due to remote-sense compensation and output voltage set-point adjustment (trim). See Figure 35. Although the output voltage can be increased by both the remote sense and by the trim, the maximum increase for the output voltage is not the sum of both. The maximum increase is the larger of either the remote sense or the trim. The amount of power delivered by the module is defined as the voltage at the output terminals multiplied by the output current. When using remote sense and trim, the output voltage of the module can be increased, which at the same output current would increase the power output of the module. Care should be taken to ensure that the maximum output power of the module remains at or below the maximum rated power. Lineage Power 21 QRW025 Series Power Modules; dc-dc Converters 36 Vdc - 75 Vdc Input, 1.2 to 3.3 Vdc Output; 25A Data Sheet August 23, 2010 Thermal Considerations versus local ambient temperature (TA) for natural convection through 2 m/s (400 ft./min.). The power modules operate in a variety of thermal environments; however, sufficient cooling should be provided to help ensure reliable operation of the unit. Heat-dissipating components are mounted on the top side of the module. Heat is removed by conduction, convection and radiation to the surrounding environment. Proper cooling can be verified by measuring the temperature of selected components on the topside of the power module (See 38). Peak temperature (Tref) can occur at any of these positions indicated in Figure 50. Note that the natural convection condition was measured at 0.05 m/s to 0.1 m/s (10ft./min. to 20 ft./min.); however, systems in which these power modules may be used typically generate natural convection airflow rates of 0.3 m/s (60 ft./ min.) due to other heat dissipating components in the system. The use of output power derating curve is shown in the following example. What is the minimum airflow necessary for a QRW025A0F operating at VI = 48 V, an output current of 25A, and a maximum ambient temperature of 70 C. Solution Given: VI = 48V Io = 25A TA = 70 C Determine airflow (v) (Use Figure 43): v = 1m/sec. (200ft./min.) 1 Note:Top view, pin locations are for reference only. OUTPUT CURRENT, IO (A) 40 Table 1. Device Temperature Output Voltage 1.2V 1.5V 1.8V 2.5V 3.3V Device Tref1 Tref1 Tref1 Tref1 Tref1 Temperature (C) 114 111 117 117 117 Heat Transfer Without Heat Sinks Increasing airflow over the module enhances the heat transfer via convection. Figures 39 through 43 shows the maximum current that can be delivered by the corresponding module without exceeding the maximum case temperature Lineage Power 25 20 15 10 5 30 40 50 60 70 80 90 LOCAL AMBIENT TEMPERATURE, TA (C) Figure 39. Output Power Derating for QRW025A0P (Vo = 1.2V) in Transverse Orientation with No Baseplate; Airflow direction from VIN (+) to VIN (-); VIN = 48V. 40 OUTPUT CURRENT, IO (A) Although the maximum Tref temperature of the power modules is per Table 1, you can limit these temperatures to a lower value for extremely high reliability. 30 0 20 Figure 38. Temperature Measurement Location. The temperature at any one of these locations should not exceed per Table 1 to ensure reliable operation of the power module. The output power of the module should not exceed the rated power for the module as listed in the Ordering Information table. 35 35 30 25 20 15 10 5 0 20 30 40 50 60 70 80 90 LOCAL AMBIENT TEMPERATURE, TA (C) Figure 40. Output Power Derating for QRW025A0M (Vo = 1.5V) in Transverse Orientation with No Baseplate; Airflow direction from VIN (+) to VIN (-); VIN = 48V. 22 Data Sheet August 23, 2010 QRW025 Series Power Modules; dc-dc Converters 36 Vdc - 75 Vdc Input, 1.2 to 3.3 Vdc Output; 25A Thermal Considerations (continued) Figure 41. Output Power Derating for QRW025A0Y (Vo = 1.8V) in Transverse Orientation with No Baseplate; Airflow direction from VIN (+) to VIN (-); VIN = 48V. Figure 42. Output Power Derating for QRW025A0G (Vo = 2.5V) in Transverse Orientation with No Baseplate; Airflow direction from VIN (+) to VIN (-); VIN = 48V. OUTPUT CURRENT, IO (A) 40 35 30 25 20 15 10 5 0 20 30 40 50 60 70 80 90 LOCAL AMBIENT TEMPERATURE, TA (C) Figure 43. Output Power Derating for QRW025A0F (Vo = 3.3) in Transverse Orientation with No Baseplate; Airflow direction from VIN (+) to VIN (-); VIN = 48V. Lineage Power 23 Data Sheet August 23, 2010 QRW025 Series Power Modules; dc-dc Converters 36 Vdc - 75 Vdc Input, 1.2 to 3.3 Vdc Output; 25A Outline Diagram Dimensions are in millimeters and (inches) Tolerences: x.x mm 0.5 mm (x.xx in. 0.02 in.) x.xx mm 0.25 mm (x.xxx in. 0.010 in.) Top View Side View Bottom View *Top Side label includes Lineage name, product designation, and data code. Optional Features, Pin is not present unless one of these options is specified. Lineage Power 24 Data Sheet August 23, 2010 QRW025 Series Power Modules; dc-dc Converters 36 Vdc - 75 Vdc Input, 1.2 to 3.3 Vdc Output; 25A Recommended Hole Pattern Dimensions are in millimeters and (inches). Lineage Power 25 Data Sheet August 23, 2010 QRW025 Series Power Modules; dc-dc Converters 36 Vdc - 75 Vdc Input, 1.2 to 3.3 Vdc Output; 25A Through-Hole Lead-Free Soldering Information The RoHS-compliant through-hole products use the SAC (Sn/Ag/Cu) Pb-free solder and RoHS-compliant components. They are designed to be processed through single or dual wave soldering machines. The pins have an RoHScompliant finish that is compatible with both Pb and Pb-free wave soldering processes. A maximum preheat rate of 3C/s is suggested. The wave preheat process should be such that the temperature of the power module board is kept below 210C. For Pb solder, the recommended pot temperature is 260C, while the Pb-free solder pot is 270C max. Not all RoHS-compliant through-hole products can be processed with paste-through-hole Pb or Pb-free reflow process. If additional information is needed, please consult with your Lineage Power representative for more details. Post Solder Cleaning and Drying Considerations Post solder cleaning is usually the final circuit-board assembly process prior to electrical board testing. The result of inadequate cleaning and drying can affect both the reliability of a power module and the testability of the finished circuit-board assembly. For guidance on appropriate soldering, cleaning and drying procedures, refer to Lineage Power Board Mounted Power Modules: Soldering and Cleaning Application Note (AP01-056EPS). Lineage Power 26 Data Sheet August 23, 2010 QRW025 Series Power Modules; dc-dc Converters 36 Vdc - 75 Vdc Input, 1.2 to 3.3 Vdc Output; 25A Ordering Information Please contact your Lineage Power Sales Representative for pricing, availability and optional features. Table 1. Product Codes Input Voltage Output Voltage Output Current Efficiency Connector Type 48V (36-75Vdc) 48V (36-75Vdc) 48V (36-75Vdc) 48V (36-75Vdc) 48V (36-75Vdc) 48V (36-75Vdc) 48V (36-75Vdc) 48V (36-75Vdc) 48V (36-75Vdc) 48V (36-75Vdc) 48V (36-75Vdc) 48V (36-75Vdc) 48V (36-75Vdc) 48V (36-75Vdc) 48V (36-75Vdc) 3.3V 3.3V 3.3V 3.3V 3.3V 3.3V 3.3V 2.5V 2.5V 1.8V 1.8V 1.5V 1.5V 1.2V 1.2V 25A 25A 25A 25A 25A 25A 25A 25A 25A 25A 25A 25A 25A 25A 25A 91% 91% 91% 91% 91% 91% 91% 90% 90% 88% 88% 87% 87% 85% 85% Through hole Through hole Through hole Through hole Through hole Through hole Through hole Through hole Through hole Through hole Through hole Through hole Through hole Through hole Through hole Product Codes QRW025A0F1 QRW025A0F4 QRW025A0F41 QRW025A0F1Z QRW025A0F1-H QRW025A0F41-H QRW025A0F1-HZ QRW025A0G41 QRW025A0G1-H QRW025A0Y4 QRW025A0Y61 QRW025A0M41-H QRW025A0M641-H QRW025A0P1 QRW025A0P1Z Comcodes 108965765 108974809 108969213 CC109101482 108968918 108981267 CC109153053 108971656 108972126 108974825 108975483 108986373 CC109155297 108965799 CC109139515 Table 2. Device Options Character and Position Ratings Characteristic Form Factor Family Designator Input Voltage Output Current Output Voltage Q R W 025A0 F G Y M P Options Pin Length Action following Protective Shutdown On/Off Logic Mechanical Features Customer Specific RoHS Definition Q = Quarter Brick Family Designator W = W ide Range, 36V-75V 025A0 = 025.0 Amps Maximum Output Current F =3.3V nominal G =2.5V nominal Y =1.8V nominal M =1.5V nominal P =1.2V nominal Omit = Default Pin Length shown in Mechanical Outline Figures 8 = Pin Length: 2.79 mm 0.25mm , (0.110 in. 0.010 in.) 7 = Case Pin (only available with H option) 6 = Pin Length: 3.68 mm 0.25mm , (0.145 in. 0.010 in.) Omit = Latching Mode 4 = Auto-restart following shutdown (Overcurrent/Overvoltage) Omit = Positive Logic 1 = Negative Logic 8 7 6 4 1 H Omit = Standard open Frame Module H = Heat plate, for use with heat sinks or cold-walls XY XY = Customer Specific Modified Code, Omit for Standard Code Omit = RoHS 5/6, Lead Based Solder Used Z Z = RoHS 6/6 Compliant, Lead free Asia-Pacific Headquarters Tel: +65 6593 7211 World Wide Headquarters Lineage Power Corporation 601 Shiloh Road, Plano, TX 75074, USA +1-800-526-7819 (Outside U.S.A.: +1-972-244-9428) www.lineagepower.com e-mail: techsupport1@lineagepower.com Europe, Middle-East and Africa Headquarters Tel: +49 89 878067-280 India Headquarters Tel: +91 80 28411633 Lineage Power reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Lineage Power DC-DC products are protected under various patents. Information on these patents is available at www.lineagepower.com/patents. (c) 2009 Lineage Power Corporation, (Plano, Texas) All International Rights Reserved. PDF name: QRW025_Series.pdf