V14
2
INPUT SPECIFICATIONS:
Voltage …...………........….................................................... 90~264Vac
Frequency ………………………………………….……………..... 47 to 63Hz
Inrush Current ………………….………….................... 120A max. @240Vac
Conducted EMI ………………………….………………CISPR/FCC Class B
Leakage Current …………………………………………….…… 3.5mA max.
OUTPUT SPECIFICATIONS:
Holdup Time ……………………………………………… 20ms typ. @115Vac
Short Circuit Protection ………………………….……………… Continuous
Over Voltage Protection ……………..........................................….....… Yes
Isolation ………………………………………… Input to output = 4,242VDC
Operating Temperature ........................................................... 0 ~ 40℃
1. Voltage setpoint at 60% full load
Storage Temperature ……………………………...….......….... -20~85℃
2. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for
Cooling …………………………………..……………….. Natural Convection
Ripple & Noise measurement @20MHz BW.
Switching Frequency …………………………………………… 45KHz Typical
3. Line regulation measured from 100Vac to 240Vac with full load.
Dimensions ……..…. 5.906x2.756x1.378 inches (150.00x70.00x35.00 mm)
4. Load regulation measured from 60% to 100% full load and from 60% to
Weight ……………………………………………………… 600g(1.36 Pounds)
20% full load (60% +/- 40% full load)
AC Inlet ……………….…………………………………...……… IEC320/C14
5. ”Various TRG Series adapters are PSE certified. PSE certification
SAFETY AND EMC:
alone is not sufficient for importation into Japan. A valid PSE mark
Emission and lmmunity ……… EN55022 Class B, FCC Part 15 Class B
must contain the name of the importer as shown in the example below.
EN61000-3-2,EN61000-3-3, EN55024
If PSE mark is required, the name of the registered importer must be
supplied to Cincon on order placement. Product labels will not contain
Safety ………………………..IEC60950-1, EN60950-1, UL60950-1
PSE mark if importer name is not supplied. Consult factory or local
representative for details”
Mechanical Specification
Typical at 25˚C, nominal line and 60% load, unless otherwise Specified
0%
25%
50%
75%
100%
0 10 20 30 40 50 60
Ambient Temperature(
o
C)
Rated Load(%)
20LFM(Natural Convection)
UNIT:inches(mm)
IEC320/C14 DC Plug:Right Angle(ψ5.5/ψ2.5) L12mm
DC Plug type: V+ ─●)─ V-
16AWG/1800mm
Millimeters:X.XX±0.5
Tolerance:Inches:X.XXX±0.02
All Dimensions are in inches(mm)
LED