Installation Data Sheet
LAMBDA ELECTRONICS INC.
LAMBDA ELECTRONICS INC.LAMBDA ELECTRONICS INC.
LAMBDA ELECTRONICS INC.
PM10-12 D DC-DC Converters
IM-PM1012D 7/99 REV: B
λ
λλ
λ
The PM10 is a DC-DC converter which provides a regulated output at power levels up to 10 watts. It accepts a wide range DC
input and provides a fully isolated, regulated output. In operation, either (or neither) input pin, as well as either (or neither)
output pin can be grounded. PM10 units provide full output power for ambient temperatures up to 70°C, with linear derating
from 70°C to zero power at 105°C. In forced air applications, full output power can be maintained as long as the chassis
temperature, as measured in the center of the unit’s label, is maintained at less then or equal to 100°C.
Note: For safety agency approval of the end use equipment to safety standards (such as UL 1950 3rd Edition, CAN/CSA C22.2
No.950-95, DIN VDE 0805 and EN 60950), the output of the converter is ELV if the input to the converter is ELV; the output of
the converter is SELV only if its input is SELV. W hen the input is between 60Vdc and 75Vdc, the output may be SELV only if
the DC input is reinforced insulated from the AC mains and SELV reliability fault tests are successfully conducted on the DC
power source in combination with the converters (these tests have already been performed on the converters). The input and
output are to be both floating or both grounded. The converter is to be protected by the specified fuse, provided in the
ungrounded leg.
Specifications:
PM10-12D SERIES
MODEL PM1012-D12 PM1012-D15
ITEMS OUTPUT 1 OUTPUT 2 OUTPUT 1 OUTPUT 2
Nominal Output Voltage V+12 -12 +15 -15
Voltage Accuracy - ± 1.5%
Output Current (Power) @ 70°C A/W 0.42 (5.0) .33 (5.0)
Operating Temperature Range - -25°C to + 105°C. Derate linearly above + 70°C to 0 watts at 105°C
Output Voltage Adjustment Range VOutput is fixed, or not adjustable
Output Ripple (20MHz BW) MV 25mV RMS / 100 mVp-p
Line Regulation MV 48 total output, 60 per output 60 total output, 75 per output
Load Regulation (25% - 100%) MV 240 total outpu t, 360 per output 300 total outpu t, 450 per output
Temperature Coefficient -± 0.015% / °C
Overshoot - No overshoot at turn on, turn off, power failure or removal of a short circuit
Input Voltage Range -9-18 Vdc
Efficiency (Typical) % 76
No Load Input Power W0.4
Conducted EMI - EN55022 Level B, FCC Level B, ANSI 63.12-1987 with external filter
Short Circuit Protection -Continuous
Max Load Capacitance* - 100uF (Total Output) 47uF (Total Output)
Overvoltage Clamp Point (fixed) V30 max. (total output) 37.5 max. (total output)
Isolation (Input to Output) - 500Vac, 700Vdc, 10M
Regulatory Agency Compliance** -ETSI-300-132-2, Bellcore TR-TSY-001003, UL1950 3rd Edition, CAN/CSA
C22.2 No. 950-95, EN 60950, VDE 0805
Mounting & Connections - 0.040” diameter, 0.22” long solderable pins
Cover -0.032” anodized alumin um
Size (W.H.D.) in 1.0” X 2.0” X 0.335”
Storage Temperature --40°C to + 105°C
Cooling - Convection cooling allows full o/p rating.
Vibration -2.5G RMS,10Hz - 50 Hz, random vibration, 10 minutes per axis
Relative Humidity - 5% - 95%, non-condensing
Altitude -10,000 feet max. operating / 45,000 feet max. storage
Fungus Proofing - Units are inherently fungus inert
Thermal Cycling -1 hour @ -25°C ramped to 1 hour @ +25°C ramped to 1 hour @ +100°C,
10 cycles ramp = 5°C / minute
Warranty - 2 year warranty includes parts and labor
* To Avoid current limit circuit activation into a capacitive load wi th no series impedance. Assumes full constant DC load
parallel with capacitance at minimum input line voltage.
**Regulatory Agency compliance testing is in process. Check individual unit’s label for appropriate
agency logos.
Note: Regulation values pertain to operation with output currents above 25% of rated load current.
Installation Data Sheet
LAMBDA ELECTRONICS INC.
LAMBDA ELECTRONICS INC.LAMBDA ELECTRONICS INC.
LAMBDA ELECTRONICS INC.
PM10-12 D DC-DC Converters
IM-PM1012D 7/99 REV: B
λ
λλ
λ
Recommended Circuit Hook up:
1. Input can have -Vin, +Vin or neither terminal grounded. Input ground connection should be placed as close to
PM unit input as possible.
2. Output can have -Vo, +Vo or neither terminal grounded. Output ground connection should be placed as close to
PM unit input as possible.
3. Recommended input fusing: 2A (Buss PCB2, or equivalent)
Input fuse must be connected in series with the ungrounded input lead.
Mechanical Information:
PM10 units are designed for installation on printed wiring boards. The metal chassis has 0.015” taps built in to provide
clearance between the pins and the PC board to allow for wave soldering. During wa ve soldering, the top surface of the board
to which the PM unit is mounted (measured ½” from the edge of the PM unit) should be maintained at a temperature of no
more than 180°C for no more than 30 seconds. The chassis of the PM unit is electrically isolated from both the input and
output circuitry and should be left floating in a typical installation.
Total Output Power vs Ambient Operating Temperature
-20°-10°0°10°20°30°40°50°60°70°80°90°100°
Temperature (°
°°
°C)
12V & 15V Outputs
Output
Power
Watts
12
10
8
6
4
2
0
Optional
EMI
0.1uF
Load
1uF 50 ohm
Coax Cable 50 Oscillo-
scope
DC
Source
9 – 18V
+
-
+Vo
-Vo-Vin
+Vin
PM1012D
Fuse
DVM
System Ground
Appropriate hook up l ocat i on
for test equipment to monitor
output of PM unit
com
Load