Fiber Photoelectric Sensor E3S-X3 CSM_E3S-X3_DS_E_3_1 Excellent Detection of Color Differences Ordering Information, Ratings, and Specifications Amplifiers Model E3S-X3CE4 Item Sturdy model Appearance Light source (wave length) Red LED (660 nm) Power supply voltage 12 to 24 VDC 10% Current consumption 50 mA max. Response time Operate or reset: 1 ms max. Control output Output current: 1.5 to 4 mA, Load current: 80 mA max. (residual voltage: 2 V max.) Operation indicator Light indicator (red), Stability indicator (green) Ambient illumination Sunlight: 10,000 lx max.; Incandescent lamp: 3,000 lx max. Ambient temperature Operating: -25C to 55C (with no icing) Storage: -25C to 70C Ambient humidity Operating: 35% to 85% Storage: 35% to 95% Insulation resistance 20 M min. (at 500 VDC) between current-carrying parts and case Dielectric strength 500 VAC at 50/60 Hz for 1 minute between current-carrying parts and case Degree of protection IEC IP66 Material Case: Zinc die-cast 1 E3S-X3 Fiber Units Through-beam and Grooved-type Sensors Sensing method Through-beam Feature Model Long distance E32-T11L E32-T12L General-purpose E32-T21L E32-T22L E32-TC200 E32-TC200B E32TC200B4 90 mm (40 mm) Appearance M4 screw 3-mm dia. M3 screw 2-mm dia. M4 screw Item With E3SX3CE4 M4 screw ( ): E32-TC200B4 Sensing distance (standard sensing object) 250 (650) mm * 250 mm 65 mm Opaque: Opaque: Opaque: 0.9-mm dia. min. 1.4-mm dia. min. 1.4-mm dia. min. Minimum sensing object (copper 0.3-mm dia. strand) (typical) 120 mm (1 m) * Opaque: 1-mm dia. min. 120 mm Opaque: 1-mm dia. min. 0.2-mm dia. Ambient operating temperature -40 to 70C Ambient operating humidity 35% to 85% Permissible bending radius 25 mm min. Fiber sheath materials Black polyethylene * Values in parentheses: when using the E39-F1 Lens Unit Sensing method Through-beam Feature Model Attachment for E39-F5 General-purpose E32-T22 E32-TC200E E32-TC200F E32TC200F4 E32-TC200A Flexible (resists breaking) E32-T11 E32-T21 90 mm (40 mm) Appearance 2-mm dia. M3 screw Item With E3SX3CE4 M3 screw M3 screw M4 screw M3 screw ( ): E32-TC200F4 Sensing distance (standard sensing object) 35 mm Opaque: 0.5-mm dia. min. Minimum sensing object 0.1-mm dia. (copper strand) (typical) 120 mm Opaque: 1-mm dia. min. 120 mm (1 m) * Opaque: 1-mm dia. min. 0.2-mm dia. 35 mm Opaque: 0.5-mm dia. min. 0.1-mm dia. Ambient operating temperature -40 to 70C Ambient operating humidity 35% to 85% Permissible bending radius 25 mm min. 4 mm min. Fiber sheath materials Black polyethylene Vinyl chloride * Values in parentheses: when using the E39-F1 Lens Unit 2 E3S-X3 : Indicates models that do not allow free cutting. Sensing method Through-beam Feature Model Long distance Curl cable E32-TC200D E32-TC200D4 E32-TC200C Through-beam with lens Side-view Through-beam Screwmounting type Space saving E32-T14L E32-T24 E32-T14 Suitable for explosion-proof applications E32-T17L 90 mm (40 mm) Appearance M4 screw 1-mm dia. M14 screw (): E32-TC200D4 Item With E3SX3CE4 3-mm dia. M6 screw Sensing distance 100 (600) mm *1 (standard sensOpaque: 1-mm dia. ing object) min. 100 mm Opaque: 1-mm dia. min. 80 mm 30 mm 600 mm 5,000 mm Opaque: 1Opaque: 0.5- Opaque: 4Opaque: 10-mm mm dia. min. mm dia. min. mm dia. min. dia. min. Minimum sensing object (copper 0.2-mm dia. strand) (typical) 0.1-mm dia. Ambient operating temperature -40 to 70C Ambient operating humidity 35% to 85% Permissible bending radius 25 mm min. Fiber sheath materials Black polyethylene Fluorocarbon polymer-covSensing method ered throughbeam Withstands chemicals and Feature harsh environments Model E32-T12F Screen through-beam Four-head through-beam Suitable for detecting over a 10-mm area Simultaneous detection in four locations E32-T16 E32-M21 Appearance 5-mm dia. M3 screw 0.8-mm dia. Heat-resistant through-beam Heat resistant up to 150C E32-T51 M4 screw Heat resistant up to 300C E32-T61-S Groove type No optical axis adjustment required E32-G14 M4 screw Item 550 mm *2 With E3SX3CE4 Sensing distance 550 mm (Field of view: 10 Opaque: 4-mm dia. mm width) (standard sensmin. Opaque: 10-mm ing object) 100 mm Opaque: 2-mm dia. min. 120 mm Opaque: 1-mm dia. min. Minimum sensing 0.9-mm dia. object (copper strand) (typical) 0.3-mm dia. 0.1-mm dia. 100 mm Opaque: 1.5-mm dia. min. dia. min. Ambient operating temperature -30 to 70C Ambient operating humidity 35% to 85% Permissible bending radius Fiber sheath materials 0.4-mm dia. *2 0.8-mm dia. -40 to 70C -40 to 150C *3 -40 to 300C 40 mm min. 25 mm min. 35 mm min. 25 mm min. Black polyethylene covered with fluorocarbon polymer Black polyethylene Fluororesin SUS *1. When using the E39-F1 Lens Unit. Ambient operating temperature specification is the same as the Lens Unit (-40 to 200C). *2. The sensing distance is 400 mm when a 1.0-mm-wide Slit is attached. The minimum diameter of the sensing object is 0.35 mm. The sensing distance is 300 mm when a 0.5-mm-wide Slit is attached. The minimum diameter of the sensing object is 0.25 mm. (Use a Slit with 0.5-mm width if the sensing distance is less than 300 mm. The measurements of distances are shown in the figure on the right.) *3. For continuous operation, use the products within the temperature ranging from -40C to 130C. 100 mm (groove width) Opaque: 4-mm dia. min. -40 to 70C Black polyethylene Sensing object 3 E3S-X3 Reflective Sensors : Indicates models that do not allow free cutting. Sensing method Reflective Feature Model Long distance E32-D11L E32-D21L General-purpose E32-D22L E32-DC200 E32-DC200B E32DC200B4 E32-DC200E 90 mm (40 mm) Appearance M4 screw M6 screw 3-mm dia. M6 screw Item With E3SX3CE4 M6 screw Sensing distance (standard sensing object) 65 mm (white paper 3 x 3 cm) Minimum sensing object (copper 0.015-mm dia. strand) (typical) 18 mm (white paper 1.5 x 1.5 cm) 20% of sensing distance max. Ambient operating temperature -40 to 70C Ambient operating humidity 35% to 85% Permissible bending radius 25 mm min. Fiber sheath materials Black polyethylene Sensing method Feature Model 50 mm (white paper 3 x 3 cm) Reflective General-purpose E32-DC200F E32DC200F4 Flexible (resists breaking) E32-D11 E32-D21 Expandable curl cable E32-DC200C E32-DC200D E32-DC200D4 90 mm (40 mm) Appearance M3 screw M6 screw M3 screw M6 screw M6 screw ( ): E32-DC200D4 Item Sensing distance (standard sensing object) 12 mm (white paper 1.5 x 1.5 cm) 0.03-mm dia. Differential travel With E3SX3CE4 M3 screw ( ): E32-TC200B4 12 mm 30 mm 7 mm (white paper 1.5 (white paper 3 (white paper x 1.5 cm) x 3 cm) 1.5 x 1.5 cm) 15 mm (white paper 3 x 3 cm) Sleeve adjustment E32-DC9G E32-DC9G4 90 mm (40 mm) 1.2-mm dia. ( ): E32-DC9G4 20 mm (white paper 1.5 x 1.5 cm) Minimum sensing object (copper 0.03-mm dia. strand) (typical) Differential travel 20% of sensing distance max. Ambient operating temperature -40 to 70C Ambient operating humidity 35% to 85% Permissible bending radius 25 mm min. 4 mm min. 25 mm min. Fiber sheath materials Black polyethylene Vinyl chloride Black polyethylene 4 E3S-X3 : Indicates models that do not allow free cutting. Sensing method Superfine reflector Coaxial reflective Minute Feature object sensing Model Appearance Item With E3SX3CE4 E32-D33 Side-view reflective Positioning accuracy E32-CC200 E32-D32 Long distance Space saving E3-D14L E32-D24 6-mm dia. 3-mm 0.8-mm dia. dia. M6 screw 50 mm (white paper 3 x 3 cm) Minimum sensing 0.015-mm object (copper dia. strand) (typical) 0.03-mm dia. Withstands chemicals and harsh environments Heat resistant to 150C E32-D12F E32-D51 2-mm dia. 2-mm dia. Sensing distance 4 mm (standard sens(white paper ing object) 1.5 x 1.5 cm) Reflective covered with Heat-resistfluorocaring reflective bon polymer 6-mm dia. 20 mm (white paper 3 x 3 cm) 25 mm (white paper 3 x 3 cm) 10 mm (white paper 1.5 x 1.5 cm) M6 screw 35 mm (white paper 3 x 3 cm) 40 mm (white paper 3 x 3 cm) -30 to 70C -40 to 150C *1 Differential travel 20% of sensing distance max. Ambient operating temperature -40 to 70C Ambient operating humidity 35% to 85% Permissible bending radius 25 mm min. 40 mm min. 35 mm min. Black polyethylene Black polyethylene covered with fluorocarbon polymer Fluororesin Fiber sheath materials Sensing method Feature Model Appearance Heat-resistant reflective Heat resistant up to 300C Heat resistant up to 400C E32-D61 E32-D73 M6 screw M4 screw 1.25-mm dia. Retro-reflective (with MSR function) Convergent-reflective Transparent object detection Detects wafers and small differences in height E32-R21+E39-R3 *4 M6 screw E32-R16+E39-R1 *4 E32-L25 *3 E32-L25A*3 E39-R1 Reflector E39-R3 Reflector Item With E3SX3CE4 30 to 200 mm Sensing distance (with E39-R3 Reflector, (standard sens30 mm (white paper 3 x 3 cm) Opaque: 35-mm dia. ing object) min.) 100 to 1,200 mm (with E39-R1 Reflector, 3.3 mm white paper 3 x Opaque: 35-mm dia. 3 cm) min.) *2 Minimum sensing object (copper 0.03-mm dia. strand) (typical) 0.6-mm dia. 0.3-mm dia. Differential travel 5% max. of sensing distance --- Ambient operating temperature -40 to 300C Ambient operating humidity 35% to 85% Permissible bending radius 25 mm min. Fiber sheath materials SUS -40 to 400C -40 to 70C 0.025-mm dia. -25 to 55C -40 to 70C Black polyethylene *1. For continuous operation, use the products within the temperature ranging from -40C to 130C. *2. The sensing distance is 30 to 80 mm for the E39-RSA with a Tape-type Reflector, and 30 to 120 mm for the E39-RSB. *3. Refer to Dimensions on pages 24 and 25 for the standards for sensing distances. *4. The ambient operating temperature specification of the Reflectors is the same as that of the E32-R21 and E32-R16. 5 E3S-X3 Fiber Unit Specifications Ambient operating temperature No icing or condensation Ambient operating humidity No condensation Ambient storage temperature Heat-resistant Fiber Units: -40 to 110C (with no icing or condensation) Other Fiber Units: -40 to 70C (with no icing or condensation) Ambient storage humidity 35% to 95% (with no icing or condensation) Vibration resistance (destruction) 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance (destruction) 500 m/s2 (50G) for 3 times each in X, Y, and Z directions Attachments Name Small Spot Lens Unit Detection over 0.5Applications mm-dia. spots Model Long-distance Lens Unit Side-view Unit Increasing sensing distance Change detection direction to side view E39-F1 E39-F2 E39-F3A Reflective Through-beam Through-beam Sensing method Item Applicable fibers With E3SX3CE4 Sensing distance E32-D32 E32-T11L E32-TC200 E32-T11 E32-TC200C E32-T11L E32-T61-S E32-TC200 E32-T11 E32-TC200C E32-T61-S 6 to 12 mm 650 mm 1,000 mm 600 mm 120 mm 100 mm Standard sens- White paper ing object 3 x 3 mm Opaque: 4-mm dia. min. Opaque: 3-mm dia. min. 20 to 60 Directional angle --- 5 to 40 Differential travel 20% max. of sensing distance --- Ambient temperature Material 100 mm -40 to 70C -40 to 200C * Shaft Aluminum Brass Lens Optical glass * Use the Fiber Unit within the specified ambient operating temperature range specified for it. If the Fiber Unit is used with the E32-T61-S, make sure the ambient temperature is -40 to 200C. 6 E3S-X3 Lens-equipped Reflective Unit Side-view Reflective Unit Converting through-beam sensors to long distance reflective sensors Converting through-beam to reflective sensor Name Applications Model E39-F3 E39-F5 Reflective Reflective Sensing method Item Applicable fibers With E3SX3CE4 E32-T11L E32-TC200 5 to 90 mm 35 to 50 mm Standard sensing object 20 x 20 cm (white paper) 1.5 x 1.5 cm Sensing distance Directivity E32-T11 E32-TC200C E32-TC200A 20 mm (5 x 5 cm) 20% max. of sensing distance -40 to 200C * Differential travel Material E32-T61-S Shaft Brass Lens Optical glass Base Aluminum Reflector -40 to 70C ----Brass --- Stainless steel * Use the Fiber Unit within the specified ambient operating temperature range specified for it. If the Fiber Unit is used with the E32-T61-S, make sure the ambient temperature is -40 to 200C. Focal length d (mm) Beam Spot Characteristics E39-F3A with E32-D32 16 14 12 d Fiber E32-D32 : Spot diameter (mm) : Insertion d : Focal distance 1.0 10 0.8 8 0.5 6 4 2 0 4 8 12 16 20 Insertion distance (mm) 7 E3S-X3 Name Length (L) Model Protective Spiral Tubes 500 mm E39F32A5 1,000 mm E39F32A 500 mm E39F32B5 1,000 mm E39F32B 500 mm E39F32C5 1,000 mm E39F32C L Head connector Tube E32-TC200E E32-TC200F(4) E32-T21 E32-T21L 1,000 mm E39F32D5 E39F32D * Refer to page 13 for information on attaching the end cap. Appearance Item 500 mm End cap E32-TC200 E32-TC200B(4) E32-T11 E32-T51 E32-T11L Applicable fiber E32-DC200E E32-DC200F(4) E32-D21 Ambient operating temperature -40C to 150C (Do not exceed the operating temperature of the fiber) Ambient operating humidity 35% to 85% Permissible bending radius 30 mm min. Tensile strength Between head connector and end cap with tube: 1.5 N*m max. Tube: 2 N*m max. Compression load Tube: 29.4 N max. E32-DC200 E32-DC200B(4) E32-CC200 E32-D11 E32-D51 E32-D11L Accessories Name Features Model Fiber Cutter Used to cut fibers to desired lengths E39-F4 Fine-fiber Attachment Fiber Connector Used when inserting fine Used to connect additionfibers into the amp al fibers for extension E39-F9 Sleeve Bender Used to bend fiber sleeves E39-F10 E39-F11 Appearance Item Applicable fiber Provided/Order separately All models equipped with fibers that can be trimmed. E32-DC200E, -TC200E E32-DC200F(4), -TC200F(4) E32-D21, -D21L, -D22L, E32-T21, -T21L, -T22L, E32-D32, -T22 E32-D24, -T24 E32-D33 E32-R21 Provided with Fiber Units. E32-DC200, -TC200 E32-DC200B(4), -TC200B(4) E32-TC200A E32-T14, -G14 E32-D11L, -T11L, -T12L E32-D14L, -T14L E32-T17L E32-TC200B(4) E32-TC200D(4) E32-DC200F(4), -TC200F(4) E32-DC9G(4) Order separately. 8 E3S-X3 Engineering Data (Typical) Fiber Length vs. Sensing Distance Fiber length (m) E3X-N@@@, E32-DC200 (Change in rated value) Sensing distance Y (mm) Fiber length (m) I/O Circuit Diagrams Model Wire color Item Power polarity State of output transistor E3X-N@@@, E32-TC200 (Change in rated value) Sensing distance Y (mm) Fiber Units with Reflective Sensors (Fiber length of 2 m corresponds to 100%) Sensing distance (%) Sensing distance (%) Through-beam Fiber Units (Fiber length of 2 m corresponds to 100%) Fiber length X (m) Fiber length X (m) Conductor colors have been changed as a result of changes in standards. The previous colors are given in brackets. E3S-X3CE4 Blue (black) *1 Brown (red) *1 0V 0V Brown (red) *1 + Blue (black) *1 + Light-ON Dark-ON Brown (red) *1 12 to 24 VDC Light indicator (Red) Output circuit Stability indicator (Green) Photoelectric Sensor main circuit Black (white) 1.5 to 4 mA Z Load 1 (relay) 80 mA max. Load 2 *2 1.5 to 4 mA Blue (black) *1 0V Z: Zener Diode (Vz = 30 V) Timing charts Incident light No incident light Incident light No incident light Light indicator ON (red) OFF ON Output transistor OFF Operate Load 1 Reset (e.g., relay) Light indicator ON (red) OFF Output ON transistor OFF Operate Load 1 Reset (e.g., relay) Load 2 H L Between brown (red) and black (white) H L Load 2 Between blue (black) and black (white) Between blue (black) and black (white) Between brown (red) and black (white) Note: Not equipped with load short-circuit protection function. *1. Reverse the polarity of the power supply to switch the output status. *2. Voltage output (when connected to a transistor circuit) Connection Conductor colors have been changed as a result of changes in standards. The previous colors are given in brackets. Connection with S3D2 Sensor Controller Connection with S3D8 Sensor Controller Blue (black) Black (white) Black (white) Blue (black) 0 V Brown (red) E3S-X E3S-X +12 V 0V Note: A maximum of two S3D2 Sensors can be connected. Brown (red) +12 V Note 1. Operation can be reversed using the L -Key. 2. A maximum of eight S3D2 Sensors can be connected. 9 E3S-X3 Adjustment Methods Sensitivity Adjustment Adjust the sensitivity so that the indicators appear as shown in the following table during various sensing situations. Type Sensing condition Light status Interrupted Through-beam Incident No sensing object Red Green Red Red indicator: ON Green indicator: ON Incident Sensing object present Green Red Red indicator: ON Green indicator: ON Sensing object Interrupted No sensing object Green Red Red indicator: OFF Green indicator: ON Reflective Incident Green Red Red indicator: ON Green indicator: ON Color with good reflection Interrupted Green Red Red indicator: OFF Green indicator: ON Color with bad reflection Interrupted Green Red Red indicator: OFF Green indicator: ON Sensing object present Reflector Retro-reflective Incident Sensing object present Reflector Green Red indicator: OFF Green indicator: ON Sensing object present Detection of differences in color or brightness Indicator status Green Red Red indicator: ON Green indicator: ON Note 1. When the sensitivity is set to achieve the above status, the Sensor will operate stably at all temperatures within the range specified in the ratings. 2. Even if the green indicator turns OFF, if the temperature change is less than 10C from when the setting was made, operation will remain stable. 10 E3S-X3 Safety Precautions E32-T16 Slit If a Slit is going to be used, remove the back paper and stick it on the Sensor head so that the edges are aligned. For a sensing distance of less than 45 cm, fit the Sensor head with a 0.5-mm-wide Slit. Example E32-T16's WARNING This product is not designed or rated for ensuring safety of persons. Do not use it for such purpose. sensing head Precautions for Correct Use Do not use the product in atmospheres or environments that exceed product ratings. Slit provided Fiber Units Fiber Units Heat-resistant Fiber Units (E32-D51 and E32-T51) * Make sure that the bending radius 35 mm or greater. * The fibers of these Units cannot be extended using the E39F10 Fiber Connector. * The maximum allowable temperature for continuous operation with these Units is 130C. It is 150C for shortterm use. E32-T14 and E32-G14 These Units may enter the light-ON state if there are reflecting objects at the ends of the lenses. In this case, attach the black stickers provided to the ends of the lenses. E32-T14 E32-G14 Stickers E32-L25(A) Wafer Sensors * To ensure correct performance, insert the fiber with a white line into the emitter-side port of the Amplifier. * Use a tightening torque of 0.78 N*m when mounting the Sensor head. * Do not use the Sensor in locations subject to splashing water. E39-F11 Sleeve Bender * The bending radius of the stainless steel tube should be as large as possible. The smaller the bending radius becomes, the shorter the sensing distance will be. * Insert the tip of the stainless steel tube to the Sleeve Bender and bend the stainless steel tube slowly along the curve of the Sleeve Bender. Tightening Torque * The tightening force applied to the Fiber Unit should be as follows: Screw-mounting Sensor Cylindrical Sensor Spring mounting clip Retaining screw (flat head or sunken head) (M3 max.) Toothed washers Nuts (attachment) Fiber Units M3/M4 screw M6 screw 2-mm-dia./3-mm-dia. cylinder E32-D14L E32-T12F E32-D12F E32-T16 E32-R21 E32-M21 E32-L25A Tightening torque 0.78 N*m max. 0.98 N*m max. 0.29 N*m max. 0.98 N*m max. 0.78 N*m max. 0.49 N*m max. 0.59 N*m max. Up to 5 mm to the tip: 0.49 N*m max. More than 5 mm from the tip: 0.78 N*m max. 0.78 N*m max. * Use a proper-sized spanner. 1.2-mm dia. max. 1.3-mm dia. min. R10 mm R12.5 mm R7.5 mm R5 mm 90 max. Fiber tip position mark Stainless steel tube 10 mm 10 mm Do not bend here. 11 E3S-X3 Cutting Fiber * Insert a fiber into the Fiber Cutter and determine the length of the fiber to be cut. * Press down the Fiber Cutter in a single stroke to cut the fiber. Securing the Fiber Tighten the screw to 0.2 N*m with a screwdriver. Set screw Fiber * The cutting holes cannot be used twice. If the same hole is used twice, the cutting face of the fiber will be rough and the sensing distance will be reduced. Always use an unused hole. * Use either one of the two holes on the right (refer to the following figure) to cut a thin fiber as follows: 1 An attachment is temporarily fitted to a thin fiber before shipment. Thin fiber attachment (E39-F9) Laying the Fiber Unit * Do not pull or press on the Fiber Units. The Fiber Units have a withstand force of 9.8 N or 29.4 N maximum. * Do not bend the Fiber Unit beyond the permissible bending radius given under Ordering Information. * Do not bend the edge of the Fiber Units. 20 mm min. Amplifier Unit Fiber Unit Temporarily fitted 20 mm min. 2 Secure the attachment after adjusting the position of it in the direction indicated by the arrow. * Do not apply excess force on the Fiber Units. Fiber Unit Nylon wireholder E39-F4 Cutter 3 Insert the fiber into the E39-F4 to cut. Two holes for thin fiber Three holes for standard fiber (2.2-mm dia.) Approx. 0.5 mm 4 Finished state (proper cutting state). Insertion direction * The Fiber Head could be broken by excessive vibration. To prevent this, the following is effective: Note: Insert the fiber in the direction indicated by the arrow. Fiber Insertion Position When the Fiber Unit is pressed in, it will first hit the rubber packing. Keep pressing it in further until it contacts the back surface. A one-turn loop can absorb vibrations. Tape Approx. 12 mm Fiber Unit Rubber packing Element 12 E3S-X3 Attachment Units Applications E39-F10 Fiber Connector * Use the following procedure to connect fibers via the Fiber Connector. 1 E39-F32@ Protective Spiral Tube * Insert a fiber to the Protective Spiral Tube from the head connector side (screwed) of the tube. 2 Splice Fiber Unit Protective spiral tube Fiber Unit Retention unit Retention unit Fiber Unit Fiber Unit * Each Fiber Unit should be as close as possible before they are connected. * Sensing distance will be reduced by approximately 25% when fibers are connected. * Only fibers with a 2.2-mm dia. can be connected. Fiber Unit * Push the fiber into the Protective Spiral Tube. The tube should be straight so that the fiber is not twisted when inserted. Then turn the end cap of the spiral tube. Protective spiral tube Fiber Unit * Secure the Protective Spiral Tube on a suitable place with the attached nut. Mounting panel Hexagon clamping nut Fiber Unit Protective spiral tube Toothed washer * Use the attached saddle to secure the end cap of the Protective Spiral Tube. To secure the Protective Spiral Tube at a position other than the end cap, apply tape to the tube so that the portion becomes thicker in diameter. Saddle Tube End cap 13 E3S-X3 Fiber Customization Service OMRON provides the following items to support Fiber Units. For information on available models, delivery, and prices, contact your OMRON sales representative. Stainless Tubes at Various Lengths Applicable Fiber Units E32-TC200F (0.9-mm-dia. tube) E32-TC200B E32-DC200F (1.2-mm-dia. tube) E32-DC200B (2.5-mm-dia. tube) L Can be made at lengths between 10 and 120 mm in increments of 10 mm. Tolerance: For L 40 mm = 1.0 mm For L > 40 mm = 2.0 mm (Lengths of 90 mm and 40 mm are standard sizes.) Stainless Tubes with a Bent End Applicable Fiber Units E32-TC200B E32-TC200F E32-DC200F Total length L1 L2 L1 R R Available Bending Radius (R) and Dimensions L1, L2 (Units: mm) R Bend at the base of the tube Bend at the tip of the tube Total length Total length of SUS tube L2 Control No. 1 2 3 4 S@ R5.0 A 10 15 5 10 120 max. 120 max. R7.5 B 12.5 17.5 7.5 17.5 R10.0 C 15 20 10 20 120 max. R12.5 D 17.5 22.5 12.5 22.5 120 max. Note: Tubes cannot be made to dimensions other than those listed above. An E39-F11 Sleeve Bender (sold separately) can be used to achieve dimensions other than those given above. Model Numbers Incorporating the Bending Radius, R, and Dimensions L1 and L2 Specifying L1 Only Bending radius R5 R7.5 R10 R12.5 (Units: mm) L1 (1) 10 15 12.5 17.5 15 20 17.5 22.5 Model E32E32E32E32E32E32E32E32- *1 *1 *1 *1 *1 *1 *1 *1 C200 C200 C200 C200 C200 C200 C200 C200 *2 *2 *2 *2 *2 *2 *2 *2 Specifying L1 and L2 Bending radius -S -S -S -S -S -S -S -S *3 *3 *3 *3 *3 *3 *3 *3 A1 A2 B1 B2 C1 C2 D1 D2 R5 R7.5 *1. Insert "T" for Through-beam Fiber Units and "D" for Fiber Units with Reflective Sensors. *2. Insert the "B" or "F" that appears at the end of the original model number. *3. Insert "50" if the total length is 50 mm. The total length must not exceed 120 mm. Specify L2 only Bending radius R5 R7.5 R10 R12.5 (Units: mm) L2 (1) 5 10 7.5 17.5 10 20 12.5 22.5 R10 Model E32E32E32E32E32E32E32E32- *1 *1 *1 *1 *1 *1 *1 *1 C200 C200 C200 C200 C200 C200 C200 C200 *2 *2 *2 *2 *2 *2 *2 *2 -S -S -S -S -S -S -S -S *3 *3 *3 *3 *3 *3 *3 *3 A3 A4 B3 B4 C3 C4 D3 D4 R12.5 L1 (1) (Units: mm) L2 (1) Model 10 5 E32- *1 C200 *2 -A13 10 10 E32- *1 C200 *2 -A14 15 5 E32- *1 C200 *2 -A23 15 10 E32- *1 C200 *2 -A24 E32- *1 C200 *2 -B13 12.5 7.5 12.5 17.5 E32- *1 C200 *2 -B14 17.5 7.5 E32- *1 C200 *2 -B23 17.5 17.5 E32- *1 C200 *2 -B24 15 10 E32- *1 C200 *2 -C13 15 20 E32- *1 C200 *2 -C14 20 10 E32- *1 C200 *2 -C23 20 20 E32- *1 C200 *2 -C24 17.5 12.5 E32- *1 C200 *2 -D13 17.5 22.5 E32- *1 C200 *2 -D14 22.5 12.5 E32- *1 C200 *2 -D23 22.5 22.5 E32- *1 C200 *2 -D24 *1. Insert "T" for Through-beam Fiber Units and "D" for Fiber Units with Reflective Sensor.s *2. Insert the "B" or "F" that appears at the end of the original model numbers. *1. Insert "T" for Through-beam Fiber Units and "D" for Fiber Units with Reflective Sensors. *2. Insert the "B" or "F" that appears at the end of the original model number. *3. Insert "50" if the total length is 50 mm. The total length must not exceed 120 mm. 14 E3S-X3 Sensing Distance Model E32-TC200B E32-TC200F E32-DC200F Amplifier E3X-NT E3X-NM E3X-NT E3X-NM E3X-NT E3X-NM (Units: mm) Standard R5.0 R7.5 R10.0 R12.5 product 290 270 70 65 22 20 180 170 32 30 16 15 235 220 255 240 70 65 22 20 290 270 Long-fiber Fiber Units Applicable Fiber Units (Typical Models) E32-TC200/-DC200 E32-TC200B/-DC200B E32-TC200E/-DC200E E32-TC200F/-DC200F E32-TC200A L Between 6 and 20 m in increments of 1 m (Lengths of 2 m and 5 m are standard sizes (E32-TC200/-DC200 only).) 15 E3S-X3 Dimensions (Unit: mm) Unless otherwise specified, the tolerance class IT16 is used for dimensions in this data sheet. Amplifiers E3S-X3CE4 Light indicator A (See note.) Sensitivity adjuster Fiber unit mounting screw Mounting Holes 13 dia. Two, M4 slotted hexagonal bolts Cable: 4.3C x 0.2-mm-dia. (18/0.12 dia.) vinyl-insulated round cable Standard length: 2 m Through-beam Fiber Units Two, M4 Mounting bracket Stability indicator Note: The Mounting Bracket can also be used on side A. (Two Units are used together as a set.) E32-T11L 1.4 dia. Two hexagon clamping nuts (T = 2.4) Two toothed washers (for M4) M4 x 0.7 sensing head * M2.6x0.45 3.2 3 11 (14) 7 2.2-dia. optical fiber 2,000 * Material: Nickel-plated brass E32-T12L 1.4 dia. 2.4 dia. 3 2.2-dia. optical fiber 3-dia. sensing head * 11 (14) E32-T21L 2,000 * Material: Nickel-plated brass Two hexagon clamping nuts Two toothed washers M3 x 0.5 sensing head * 0.9 dia. 1-dia. optical fiber 1.8 E39-F9 Fiber attachment 2,000 (1.7) 2.5 11 5.5 25 10 * Material: Nickel-plated brass E32-T22L 0.9 dia. 2-dia. sensing head (stainless steel) Heat-shrinkable tube 1.8 dia. 1-dia. optical fiber (2) 17 22 E32-TC200 3.2 12 Fiber attachment (E39-F9) 2,000 Two hexagon clamping nuts Two toothed washers M4 x 0.7 sensing head * 2.2-dia. optical fiber 1.0 dia. M2.6x0.45 7 25 10 3 2.4 14 2,000 * Material: Nickel-plated brass 16 E3S-X3 E32-TC200B E32-TC200B4 Two hexagon clamping nuts Two toothed washers M4 x 0.7 sensing head *2 Stainless tube (SUS304) 1.2 dia. max. 1.0 dia. 2.4 3.2 90 (40) *1 7 E32-T22 0.5 dia. 2.2-dia. optical fiber 2,000 11 *1. The value in the parentheses is for the E32-TC200B4. *2. Material: Nickel-plated brass Sensing head Heat-shrinkable tube 2 dia. (SUS303) 1.4 dia. 1-dia. optical fiber 17 12 25 10 Fiber attachment (E39-F9) 22 2,000 E32-TC200E Two hexagon clamping nuts Two toothed washers M3 x 0.5 sensing head * 0.5 dia. 25 10 1-dia. optical fiber 2.5 1.8 Fiber attachment (E39-F9) 11 5.5 2,000 * Material: Nickel-plated brass E32-TC200F E32-TC200F4 0.5 dia. Two hexagon clamping nuts Two toothed washers M3 x 0.5 sensing head *2 Stainless tube 0.9 dia. (SUS304) max. 2.5 1-dia. optical fiber 1.8 90 (40) *1 5.5 11 25 10 Fiber attachment (E39-F9) 2,000 *1. The value in the parentheses is for the E32-TC200F4. *2. Material: Nickel-plated brass E32-T200A Two hexagon clamping nuts 1.0 dia. Two toothed washers M3 x 0.5 sensing head * 2.6 dia. 2.2-dia. optical fiber 3 dia. * Material: Nickel-plated brass E32-T11 M4 x 0.7 sensing head * Two hexagon clamping nuts Two toothed washers Sixteen, 0.265 dia. Protective tube M2.6 x 0.45 3.2 2.4 3.3 15 (14) 7 2.2-dia. optical fiber 2,000 * Material: Nickel-plated brass E32-T21 M3 x 0.5 sensing head * Two hexagon clamping nuts Two toothed washers Four, 0.25 dia. Protective tube 2.5 1.8 5.5 15 11 25 10 1-dia. optical fiber Fiber attachment (E39-F9) 2,000 * Material: Nickel-plated brass 17 E3S-X3 : Indicates models that do not allow free cutting. E32-TC200C 1.0 dia. Two hexagon clamping nuts Two toothed washers M4 x 0.7 sensing head * M2.6 x 0.45 Sensing head 22 dia. 2.2-dia. optical fiber 2,000 (when straight) * Material: Nickel-plated brass E32-TC200D E32-TC200D4 Two hexagon clamping nuts Two toothed washers M4 x 0.7 sensing head *2 Stainless tube 1.0 dia. 1.2 dia. max. (SUS304) 22 dia. 2.2-dia. optical fiber *1 2,000 (when straight) *1. The value in the parentheses is for the E32-TC200B4. *2. Material: Nickel-plated brass E32-T14L 3-dia. sensing head (stainless steel) 45 Heat-shrinkable 2.2-dia. optical fiber tube 2.8 1.5 1 3 dia. 1.5 12 30 2,000 35 Sensing surface E32-T24 Fiber Attachment (E39-F9) 1-dia. Sensing head 45 1 0.5 Heat-shrinkable tube SUS304 2 dia. 1.4 dia. 1.0-dia. optical fiber 1.5 15 15 12 35 E32-T14 25 10 2,000 4.4-dia. lens unit (PMMA) Heat resistive ABS Nitrile rubber 8.2 7 Optical axis R3.5 10.5 8 Two, 3.2 dia. 2.2-dia. optical fiber 7 100.2 2.5 9.2 16 11.2 2,000 E32-T17L M14 x 1 sensing head (ABS) Two hexagon clamping nuts 10-dia. lens (PMMA) 19 2.2-dia. optical fiber 5 23 42 10,000 18 E3S-X3 : Indicates models that do not allow free cutting. E32-T12F Fluoride resin 5-dia. sensing head 4-dia. lens 4 dia. 2.2-dia. optical fiber 20 2,000 100 E32-T16 Two, R2 Mounting Holes 0.5-mm Wide Slit Seal (Supplied with the Unit in pairs) Two, M3 Sensing head (ABS) Black Lens (2 x 10) (PMMA) 1-mm Wide Slit Seal (Supplied with the Unit in pairs) 6 dia. Two, 3.2 dia. E39-L4 Mounting Bracket Black 2.2-dia. optical fiber E32-M21 M3 x 0.35 sensing head (SUS303) Two hexagon clamping nuts Two toothed washers Silicone tube * Four, 1-dia. plastic fibers * One set of silicone tubes is black while the other set is gray for easy identification when they are connected to the emitter and receiver. Sleeve 13 28 1.8 11 2,000 23 E32-T51 Two hexagon clamping nuts 1.5 dia. Two toothed washers M4 x 0.7 sensing head * 2.2-dia. optical fiber 2.85 dia. * Material: Nickel-plated brass Note: Resistant temperature is 150C. Resistant temperature is 130C when used continuously. 19 E3S-X3 : Indicates models that do not allow free cutting. E32-T61-S 1.0 dia. Two hexagon clamping nuts Two toothed washers SUS flexible tube Hexagon clamping screw M4 x 0.7 sensing head 2.8 dia. 4 dia. 5 dia. (SUS303) Sleeve 4 dia. Note: Section A resists 300C and section B (which is inserted to the Amplifier) resists 110C. The operating temperature of the section to be inserted (marked with *) must be within the operating temperature range of the Amplifier. E32-G14 Sensing head (ABS) Mounting Holes Two, M3 Optical axis Lens (PMMA) Two, 2.2-dia. optical fibers 20 E3S-X3 Reflective Fiber Units E32-D11L Two, 1.4 dia. Two hexagon clamping nuts Two toothed washers M6 x 0.75 sensing head * 4 dia. 5.2 10 Two, 2.2-dia. optical fibers 2.4 3 20 2,000 * Material: Nickel-plated brass E32-D21L Two hexagon clamping nuts Two toothed washers Two, 0.9 dia. 3.2 25 10 M7 x 0.7 sensing head * Two, 1-dia. optical fibers 2.4 Two Fiber Attachments (E39-F9) 3 15 7 2,000 * Material: Nickel-plated brass E32-D22L 25 Two, 0.9 dia. 2.7 dia. 3 dia. sensing head* 3 10 Two, 1-dia. optical fibers Two Fiber Attachments (E39-F9) 2,000 * Material: Nickel-plated brass 15 E32-DC200 Two, 1.0 dia. 3 4.8 10 E32-DC200B E32-DC200B4 Two hexagon clamping nuts Two toothed washers M6 x 0.75 sensing head Two, 2.2-dia. optical fibers (ADC) 4 dia. 2.4 17 Two hexagon clamping nuts Two toothed washers M6 x 0.75 *2 sensing head Stainless tube (SUS304) 2.5 dia. max. Two, 1.0 dia. 5.2 10 E32-DC200E Two, 0.5 dia. 17 Two hexagon clamping nuts Two toothed washers M3 x 0.5 sensing head (SUS304) 11 Two hexagon clamping nuts Two toothed washers M3 x 0.5 sensing head (SUS304) 2.5 90 (40) * 25 10 Two, 1-dia. optical fibers Two Fiber Attachments (E39-F9) 2,000 Stainless tube Two, 0.5 dia. 1.2 dia. max. (SUS304) 5.5 2,000 *1. The value in the parentheses is for the E32-DC200B4. *2. Material: Nickel-plated brass 1.8 5.5 Two, 2.2-dia. optical fibers 2.4 90 (40) *1 2.5 E32-DC200F E32-DC200F4 2,000 11 25 10 Two, 1-dia. optical fibers 1.8 Two Fiber Attachments (E39-F9) 2,000 * The value in the parentheses is for the E32-DC200F4. 21 E3S-X3 : Indicates models that do not allow free cutting. E32-D11 Two hexagon clamping nuts M6 x 0.75 Sixteen, 0.265 dia. sensing head Two toothed washers (SUS304) Protective tube 2.4 5.2 10 E32-D21 Two, 2.2-dia. optical fibers 15 17 2,000 Two hexagon clamping nuts M3 x 0.5 Two, 1-dia. Four, 0.25 dia. Sensing head * Two toothed washers optical fibers Protective tube 1.8 2.5 15 Two Fiber Attachments (E39-F9) 2,000 11 5.5 25 10 * Material: Nickel-plated brass E32-DC200C Two hexagon clamping nuts Two toothed washers M6 x 0.75 Two, 2.2-dia. sensing head* optical fibers Two 1.0 dia. 22 dia. 2.000 (when straight) * Material: Nickel-plated brass E32-DC200D E32-DC200D4 Two hexagon clamping nuts Two 1.0 dia. 2.5 dia. max. Stainless tube (SUS304) Two toothed washers M6 x 0.75 sensing head (fine-pitch thread)*2 Two, 2.2-dia. optical fibers 22 dia. 2.000 (when straight) *1 *1. The value in the parentheses is for the E32-DC200D4. *2. Material: Nickel-plated brass E32-DC9G E32-DC9G4 Sleeve Stainless tube 1.2 dia. max. (Cannot be bent in this range.) * * The value in the parentheses is for the E32-DC9G4. E32-D33 25 0.8 dia. Sensing head (SUS303) Two, 0.25 dia. 3 dia. Heat-shrinkable tube 15 15 Two, 1-dia. optical fibers 10 12 2,000 35 Two Fiber Attachments (E39-F9) E32-CC200 1.0-dia. light Sixteen, 0.25-dia. light reception fibers emission fiber 5.2 10 Two hexagon clamping nuts Two toothed washers M6 x 0.75 sensing head* 2.5 dia. 3 2.4 23 Two, 2.2-dia. optical fibers 2,000 * Material: Nickel-plated brass Note: The fiber for the emitter is identified by a white line. 22 E3S-X3 : Indicates models that do not allow free cutting. E32-D32 25 0.5-dia. light emission fiber Sensing head (SUS303) Two, 1-dia. Heat shrinkable optical fibers 2 dia. 3 dia. tube 15 Four, 0.25-dia. light reception fibers 22 10 12 2 2,000 Two Fiber Attachments (E39-F9) Note: The fiber for the emitter is identified by a white line. E32-D14L Two, 2.2 dia. optical fiber Sensing head (stainless) Heat shrinkable tube 6 dia. Light baffle Sensing surface E32-D24 Sensing head (SUS304) Heat shrinkable 2 dia. 3 dia. tube 45 1 0.5 1.5 10 Two Fiber Attachments (E39-F9) 15 Light baffle 25 Two, 1-dia. optical fibers 15 12 35 Sensing surface 2,000 E32-D12F 6-dia. sensing head Fluoride resin 5 dia. Two, 2.2-dia. optical fibers 16 2,000 E32-D51 Two hexagon clamping nuts Two toothed washers M6 x 0.75 sensing head* Two, 1.5 dia. 100 Two, 2.2 dia. optical fiber 4.9 3.1 2.4 3 10 13 17 2,000 * Material: Nickel-plated brass Note: Resistant temperature is 150C. Resistant temperature is 130C when used continuously. E32-D61 1.4 dia. Two hexagon clamping nuts Two toothed washers M6 x 0.75 sensing head (SUS303) 3.5 dia. 5 dia. SUS Flexible tube 5-dia. hexagon clamping screw Sleeve Note: Section A resists 300C and section B (which is inserted to the Amplifier) resists 110C. The operating temperature of the section to be inserted (marked with *) must be within the operating temperature range of the Amplifier. 23 E3S-X3 : Indicates models that do not allow free cutting. E32-D73 1.0 dia. Two hexagon clamping nuts Hexagon Two toothed washers clamping M4x0.7 SUS Flexible screw tube 2.8 dia. (SUS303) 5 dia. 4 dia. 1.25-dia. sensing head 1.65 dia. 2.5 dia. SUS303 Sleeve 8 7 5 5 5 2.4 20 60 10 6.5 16.5 C 2,000 B A * 13 15 6.4 Note: Section A resists 400C, section B resists 300C, and section C (which is inserted to the Amplifier) resists 110C. The operating temperature of the section to be inserted (marked with *) must be within the operating temperature range of the Amplifier. E32-R21 (One E39-R3 Reflector is supplied with the Sensor.) Two fiber attachments (E39-F9) Lens (PMMA) Sensing head (ABS) Two hexagon clamping nuts Two toothed washers 25 10 M6x0.75 Silcone tube 5 dia. 2.2 10 Two. 1-dia. optical fibers 3 2.8 11 17.8 14 2,000 27.8 E32-R16 (One E39-R1 Reflector is supplied with the Sensor.) Sensing head (ABS) Two, 2.2-dia. optical fibers Standard length: 2 m Lens (PMMA) Two, M3 screws (provided) Mounting bracket (provided) E32-L25 20 10 5 6.5 20 4 Sensing distance 4.8 Two, 2.2-dia. optical fibers 6.5 Sensing head (ABS) Two, 3.2-dia. 6-dia. Countersink 2,000 Note: The fiber for the emitter is identified by a white line. 24 E3S-X3 E32-L25A 4 5 20 10 Sensing distance 4.8 6.5 6.5 20 Sensing head (ABS) Two, 3.2 dia. 6-dia. countersink 2,000 Two, 2.2-dia. optical fibers Note: The fiber for the emitter is identified by a white line. Reflectors Reflector E39-R1 (Supplied with E32-R16) Miniature Reflector E39-R3 (Supplied with E32-R21) Material: Reflective surface: Acrylic Rear surface: ABS Material: Reflective surface: Acrylic Rear surface: ABS 40.3 34 20 Two, 3.5 dia. 0.2 Note: Mounting bracket is attached. 7.5 7 Adhesive tape 11 22.9 22.5 19.3 59.9 52 34.8 25.4 34 38 8 2.7 1.6 Two, M3 2.6 1.2 Attachments (Order separately) E39-F1 Lens Unit E39-F2 Side-view Unit M2.6 x 0.45 Effective depth: 3.8 Spot facing depth: 0.9 2.8 dia. E39-F2 Lens-equipped Reflective Unit M3 toothed Two, 4 dia. washer Two, 3.2 +0.2 0 dia. Two, M3 x 3 slotted head machine screws M2.6 Effective depth: 3.2 Spot facing depth: 0.9 12 6.4 18 4 dia. 4 dia. 5.7 8.9 9.2 Note: One set includes two units. Note: One set includes two units. 6.4 3 80.2 3.6 M3 x 6 angle fixing screw 6.5 20.7 8.5 E39-F3A Small Spot Lens Unit E39-F5 Side-view Reflective Unit Two, M3 Fiber Unit mounting holes (E32-TC200A) Two, 3.2-dia. Sensing holes 12.2 Two M2 screws for securing the fiber with an allen screw. 2.1 Two, 3,2-dia. Mounting holes 6 dia. 4 dia. 4 13 2.6 10.50.1 4 5 3 Lens (3.7 dia.) 13 2.1 dia. 23 18 Note: When mounting, remove all of the accompanying screws first and then screw the E32-TC200A into the E39-F5 until the stopper comes into contact. Note: This Lens Unit is for the E32-D32. 25 E3S-X3 Protective Spiral Tubes (Order Separately) E39-F32A, -F32A5 E39-F32B, -F32B5 M3 x 0.5; depth: 4 Head connector End cap (4.6 dia.) 3 dia. 6 dia. 12 12 L Note: 1. The length L is 1,000 for the E39-F32A/-F32B and 500 for the E39-F32A5/-F32B5. 2. The E39-F32B(5) consists of two E39-F32A(5)s. E39-F32C, -F32C5 M4 x 0.7; depth: 4 Head connector 4 dia. End cap (5.6 dia.) 7 dia. 12 12 L Note: The length L is 1,000 for the E39-F32C and 500 for the E39-F32C5. E39-F32D, -F32D5 M6 x 0.75; depth: 4 End cap (7 dia.) Head connector 5 dia. 8.5 dia. 12 12 L Note: The length L is 1,000 for the E39-F32D and 500 for the E39-F32D5. Accessories Fiber Cutter (Provided) E39-F4 8 45 24.5 Standard-fiber insertion hole Thin-fiber Attachments E39-F9 Fiber Connector (Order Separately) E39-F10 Fiber: 2.2 dia. Note: Two per set. 1.1 dia. Mark indicating position of insertion into Amplifier Unit 10 11.7 Retention clip *2 Splice *1 3.8 dia. 2.2 dia. 3.6 dia. Thin-fiber insertion hole Retention clip *2 Fiber: 2.2 dia. 2.2 dia. 3 dia. 26 12.8 *1. Material: Polyester *2. Material: Brass 25 In the interest of product improvement, specifications are subject to change without notice. 26 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2011.1 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2011 All Right Reserved.