Features
■ Formerly brand
■ Extremely high speed performance
■ Blocks high voltages and currents
■ Two TBU™ protectors in one small package
■ Simple, superior circuit protection
■ Minimal PCB area
■ RoHS compliant*, UL Recognized
Applications
■ POTS linecards
■ VolP equipment
■ Voice and data combo linecards
■ ONU, ONT
■ Gateways
■ Cable and DSL modems
TBU™ P500-G and P850-G Protectors
*RoHS Directive 2002/95/EC Jan 27 2003 including Annex.
Specifi cations are subject to change without notice.
Customers should verify actual device performance in their specifi c applications
Transient Blocking Units - TBU™ Devices
Bourns® Model P500-G and P850-G
TBU™ products are high speed, surge
protection components designed to
protect Subscriber Line Interface Circuits
(SLICs) against transients caused by
AC power cross, induction and lightning
surges.
The TBU™ device blocks surges and
provides an effective barrier behind
which sensitive electronics are not
exposed to large voltages or currents
during surge events.
Electrical Characteristics (Tamb = 25 °C)
The P-G series TBU™ devices are bidirectional; specifi cations are valid in both directions.
Symbol Parameter Min. Typ. Max. Unit
Iop Maximum current through the device that will not cause
current blocking
P500-G120-WH
P500-G200-WH
P850-G120-WH
P850-G200-WH
100
200
100
200
mA
Itrigger Typical current for the device to go from normal operating
state to protected state
P500-G120-WH
P500-G200-WH
P850-G120-WH
P850-G200-WH
150
275
150
275
mA
Iout Maximum current through the device
P500-G120-WH
P500-G200-WH
P850-G120-WH
P850-G200-WH
200
400
200
400
mA
RTBU Series resistance of the TBU™ device 50 55 Ω
Rbal Line-to line series resistance difference between two TBU™ devices 2 Ω
tblock Maximum time for the device to go from normal operating
state to protected state 1µs
Iquiescent Current through the triggered TBU™ device with 50 Vdc circuit
voltage 0.7 mA
Vreset Voltage below which the triggered TBU™ device will transition to
normal operating state 22 V
Absolute Maximum Ratings (Tamb = 25 °C)
Symbol Parameter Value Unit
Vimp Maximum protection voltage for impulse faults with rise time ≥ 1 µsec P500-Gxxx-WH
P850-Gxxx-WH
500
850 V
Vrms Maximum protection voltage for continuous Vrms faults P500-Gxxx-WH
P850-Gxxx-WH
300
425 V
Top Operating temperature range -40 to +85 °C
Tstg Storage temperature range -65 to +150 °C
Agency Approval
UL recognized component File # E315805.
Industry Standards
Description Model
Telcordia GR-1089 Port Type 2, 4 P500-G
Port Type 3, 5 P850-G
ITU-T K.20, K.20E, K.21, K.21E, K.45 P850-G