76.50 MHz
Please read
cautions and warnings and
important notes
at the end of this document.
SAW Components
SAW IF filter
Data sheet
Application
IF filter for digital radio
Usable bandwidth 3.8 MHz
Low insertion attenuation
Constant group delay
Unbalanced or balanced operation
Features
Package size 7.0 x 5.0 x 1.48 mm3
Package code QCC12C
RoHS compatible
Approximate weight 0.20 g
Ceramic package for Surface Mount Technology
(SMT)
Ni, gold-plated terminals
Electrostatic Sensitive Device (ESD)
Pin configuration
4 Balanced input or input ground
6 Input
10 Balanced output or output ground
12 Output
3,9 Case – ground
1,2,7,8 To be grounded
6
4
10
12
3,9
3May 16, 2006
B1707
76.50 MHz
SAW Components
SAW IF filter
Data sheet
Please read
cautions and warnings and
important notes
at the end of this document.
Characteristics
Temperature range for specification: T = –40 ˚C to (+85 ˚C) +105 ˚C
Terminating source impedance: ZS=27and matching network
Terminating load impedance: ZL= 1 kand matching network
min. typ.
@ 25 ˚C max.
Nominal frequency fN 76.50 MHz
Minimum insertion attenuation1)
1) Including losses in the matching network
αmin 15.4 16.9 dB
Maximum voltage gain source – load
(VL/VS)αvgsl –5.9 –4.4 dB
Amplitude ripple (p-p) ∆α
fN ± 1.89 MHz 1.0 (1.3) 1.8 dB
Pass bandwidth
αrel 1.5 dB B1.5dB 4.4 MHz
αrel 3 dB B3dB 4.7 MHz
αrel 15 dB B15dB 5.8 6.0 MHz
αrel 30 dB B30dB 6.5 6.8 MHz
Mean attenuation (relative to αmin)αrel
Upper sidelobe 86.47 ... 91.53 MHz 48.0 54.0 dB
Relative attenuation (relative to αmin)αrel
Lower sidelobe 50.00 ... 65.44 MHz 40.0 45.0 dB
65.44 ... 70.44 MHz 34.0 38.0 dB
70.44 ... 72.04 MHz 32.0 36.0 dB
Upper sidelobe 81.26 ... 82.56 MHz 37.0 40.0 dB
82.56 ... 86.47 MHz 40.0 45.0 dB
86.47 ... 91.53 MHz 44.0 48.0 dB
91.53 ... 95.21 MHz 45.0 49.0 dB
95.21 ... 100.00 MHz 45.0 49.0 dB
Group delay ripple (p–p) ∆τ
Aperture 50 kHz fN ± 1.89 MHz 190 ns
Temperature coefficient of frequency TCf –18 ppm/K
4May 16, 2006
B1707
76.50 MHz
Please read
cautions and warnings and
important notes
at the end of this document.
SAW Components
SAW IF filter
Data sheet
Matching network1) (based on four port measurement, quality factors QL = 40, QC = 90)
1) The input matching circuit has been designed as a power match of the filter’s input port to 175 . In a second step
it has been optimized in a narrow range in order to operate at 27 with optimum filter performance.
Cs1 = 12 pF
Lp2 = 220 nH
Lp3 = 680 nH
Cs4 = 5.6 pF
Cs1
Cs1
Lp2 Lp3
Cs4
Cs4
5May 16, 2006
B1707
76.50 MHz
SAW Components
SAW IF filter
Data sheet
Please read
cautions and warnings and
important notes
at the end of this document.
Transfer function
Transfer function (pass band)
6May 16, 2006
B1707
76.50 MHz
Please read
cautions and warnings and
important notes
at the end of this document.
SAW Components
SAW IF filter
Data sheet
Characteristics
Temperature range for specification: T = –40 ˚C to +85 ˚C
Terminating source impedance: ZS=50(single ended) and matching network
Terminating load impedance: ZL= 50 (single ended) and matching network
min. typ.
@ 25 ˚C max.
Nominal frequency fN 76.50 MHz
Minimum insertion attenuation1)
1) Including losses in the matching network
αmin 11.3 12.8 dB
Amplitude ripple (p-p) ∆α
fN ± 1.89 MHz 1.0 1.3 dB
Pass bandwidth
αrel 1.5 dB B1.5dB 4.3 MHz
αrel 3 dB B3dB 4.6 MHz
αrel 15 dB B15dB 5.8 6.0 MHz
αrel 30 dB B30dB 6.6 6.9 MHz
Mean attenuation (relative to αmin)αrel
Upper sidelobe 86.47 ... 91.53 MHz 46.0 50.0 dB
Relative attenuation (relative to αmin)αrel
Lower sidelobe 50.00 ... 65.44 MHz 37.0 41.0 dB
65.44 ... 70.44 MHz 35.0 39.0 dB
70.44 ... 72.04 MHz 33.0 36.0 dB
Upper sidelobe 81.26 ... 82.56 MHz 32.0 35.0 dB
82.56 ... 86.47 MHz 39.0 42.0 dB
86.47 ... 91.53 MHz 40.0 42.0 dB
91.53 ... 95.21 MHz 46.0 50.0 dB
95.21 ... 100.00 MHz 46.0 50.0 dB
Group delay ripple (p–p) ∆τ
Aperture 50 kHz fN ± 1.89 MHz 200 ns
Temperature coefficient of frequency TCf –18 ppm/K
7May 16, 2006
B1707
76.50 MHz
SAW Components
SAW IF filter
Data sheet
Please read
cautions and warnings and
important notes
at the end of this document.
Matching network (based on four port measurement, quality factors QL = 40, QC = 90)
Maximum ratings
Operable temperature range T –40 / +105 ˚C
Storage temperature range Tstg –40 / +105 ˚C
DC voltage VDC 0 V
Source power PS10 dBm source impedance 50
Ls1 = 430 nH
Lp2 = 820 nH
Ls3 = 560 nH
Ls1
Lp2
Ls3
8May 16, 2006
B1707
76.50 MHz
Please read
cautions and warnings and
important notes
at the end of this document.
SAW Components
SAW IF filter
Data sheet
Transfer function
Transfer function (pass band)
9May 16, 2006
B1707
76.50 MHz
SAW Components
SAW IF filter
Data sheet
Please read
cautions and warnings and
important notes
at the end of this document.
References
Type B1707
Ordering code B39765B1707H310
Marking and package C61157-A7-A95
Packaging F61074-V8170-Z000
Date codes L_1126
S-parameters B1707_NB_UN.s4p
Soldering profile S_6001
RoHS compatible defined as compatible with the following documents:
"DIRECTIVE2002/95/ECOFTHEEUROPEANPARLIAMENT
AND OF THE COUNCIL of 27 January 2003 on the restriction
of the use of certain hazardous substances in electrical and
electronic equipment. 2005/618/EC from April 18th, 2005,
amending Directive 2002/95/EC of the European Parliament
and of the Council for the purposes of establishing the maxi-
mum concentration values for certain hazardous substances in
electrical and electronic equipment."
For further information please contact your local EPCOS sales office or visit our webpage at
w
ww.epcos.com .
Published by EPCOS AG
Surface Acoustic Wave Components Division
P.O. Box 80 17 09, 81617 Munich, GERMANY
EPCOS AG 2006. This brochure replaces the previous edition.
For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or
t
he international Representatives.
Due to technical requirements components may contain dangerous substances. For information on
t
he type in question please also contact one of our Sales Offices.
10 May 16, 2006
Important notes
T
he following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical
requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application.
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar
with them than the customers themselves. For these reasons, it is always ultimately incum-
bent on the customer to check and decide whether an EPCOS product with the properties
described in the product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of passive electronic compo-
nents or failure before the end of their usual service life cannot be completely ruled
out in the current state of the art, even if they are operated as specified. In customer
applications requiring a very high level of operational safety and especially in customer appli-
cations in which the malfunction or failure of a passive electronic component could endanger
human life or health (e.g. in accident prevention or life-saving systems), it must therefore be
ensured by means of suitable design of the customer application or other action taken by the
customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is
sustained by third parties in the event of malfunction or failure of a passive electronic compo-
nent.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as “hazardous”). Useful information on this will be found in our
Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more
detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order.
We also reserve the right to discontinue production and delivery of products. Conse-
quently, we cannot guarantee that all products named in this publication will always be avail-
able.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current ver-
sion of the “General Terms of Delivery for Products and Services in the Electrical
Industry” published by the German Electrical and Electronics Industry Association
(ZVEI).
7. The trade names EPCOS, CeraDiode, CSSP, PhaseCap, PhaseMod, SIFI, SIKOREL, Silver-
Cap, SIMID, SIOV, SIP5D, SIP5K, TOPcap, UltraCap, WindCap are trademarks registered
or pending in Europe and in other countries. Further information will be found on the Internet
at www.epcos.com/trademarks.